IQS300 Series Quasi-Sine Inverter. Installation & Operation Manual

Similar documents
VTC1000 Series Voltage Converter. Installation & Operation Manual

VTC610 Series Voltage Converter. Installation & Operation Manual

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL

IPS1000 Series Pure-Sine Inverter

DC to DC Step Up Converter Model: VTC305

Installation & Operation Manual PWS1000R Rack Mount Power Supply

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL VTC605 SERIES VOLTAGE CONVERTER

IPS1000 INSTALLATION & OPERATION MANUAL PURE-SINE INVERTER.

INSTALLATION & OPERATION MANUAL PWS1505 SERIES POWER SUPPLIES

INSTALLATION & OPERATION MANUAL VTC1505 SERIES VOLTAGE CONVERTER

BCD600 Series Battery Charger DC. Installation & Operation Manual

BCD610 DC Source Battery Charger

DC-AC Power Inverter SAM Manual. Please read this manual before installing your inverter

Owner's Manual. 120 Watt DC-AC Inverter Pure Sine Wave PST-12S-12A. Please read this manual before using your inverter

AC POWER SOURCE PURE SINE WAVE DC-AC INVERTERS OWNER S MANUAL

PURE SINE WAVE DC-AC INVERTERS

Battery Back-up Model: BBM-1225

Battery Back-up BBM Owner's Manual. Please read this manual BEFORE installing your inverter

Power Distribution Units AP9560 & AP9561

AUTOMATIC BATTERY CHARGER

Power Distribution Units

AUTO CHARGE 11 MODEL #: XX. AUTOMATIC BATTERY CHARGER U.L. Configuration INSTRUCTION MANUAL

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

AUTO CHARGE 12 AUTOMATIC BATTERY CHARGER

MODEL A97 SERIES. Switchmode Utility Rectifier/Battery Charger ECN/DATE

INSTRUCTION MANUAL. 12-Station HD Shop 12V Portable Battery Charger

SunCharger Portable Solar Panel Models: SC-05 SC-10. Owner's Manual. Please read this manual before operating the units

DC-AC MODIFIED SINE-WAVE INVERTER OWNER S MANUAL SI-750HP MODEL: Please read this manual before operating your inverter.

ADI-125/750 ADI-125/1500 ADI-125/2500

801 BUSINESS CENTER DRIVE MOUNT PROSPECT, ILLINOIS

RU BMS Power Supply and Battery Management System Owners Guide

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

MIL-24/2600Q MIL-24/3200DQ

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

O W N E R ' S M A N U A L

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

LESTRONIC II BATTERY CHARGER BUILT-IN OR PORTABLE CHARGERS

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

LESTRONIC II BATTERY CHARGER MODEL 19740

OWNERS MANUAL JANUARY 2007 ISO

801 BUSINESS CENTER DRIVE MOUNT PROSPECT, ILLINOIS Ext. 322

WARNINGS, CAUTIONS AND NOTES

DC to AC Power Inverters

A48 / A48B (base plate) BATTERY CHARGER

DC to AC Power Inverters

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

WF-5110R True Sine Wave Inverter

PROwatt 150 DC to AC Power Inverter. Owner s Guide

Model: PIF-2000 Power Inverter Converts 12V DC Battery Power to AC Household Power

GSL Electronics Modified Sine Wave Power Inverters

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Toll Free DX100. Owner's Guide. Printed in China

WF-5110R True Sine Wave Inverter

OWNERS MANUAL JANUARY 2007 ISO

Inverter User Manual

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

A39 UNIVERSAL SCR CHARGER

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

Pure Sine Wave Inverter 600W-24V User Manual

Power Inverter 400 MW Owner s Manual

CLEAN POWER TM CPS Series Operator s Manual

BATTERY SAVER LOW RIPPLE HO

V 2.0 DC TO AC POWER INVERTER PWRINV500012W PWRINV500024W PWRINV500036W PWRINV500048W. Instruction Manual

S150,S300 Series Pure Sine Wave Inverter User s Manual

WF-5100 Series True Sine Wave Inverters

1200+ WITH LVD (LOW VOLTAGE DISCONNECT) USER GUIDE

installation kit Ask your retailer!

HE1U 1248 BMS High Efficiency 1U AC to DC Power Supply Owners Guide SPECIFICATIONS

installation and operating instructions for the following xtreme Battery chargers:

XPower Inverter 450. Owner s Manual

Power InverterTM Watt. Continuous. User's Manual. WAGAN Corp. Limited Warranty Registration Form. Item no

Xantrex Inverter 300. Owner s Guide

User s Manual. Automatic Switch-Mode Battery Charger

The Power of Reliability INSTRUCTION MANUAL

EN120 EN180. Owner's Guide Conforms to / Conforme à UL std. 458, Toll Free

230VAC Power Inverter 400W Owner s Manual

DC TO AC POWER INVERTER

INSTRUCTION MANUAL FOR PC63 CAGE

24 VOLT AUTOMATIC BATTERY CHARGER PART NO

10 AMP ON BOARD BATTERY CHARGER

Operating Instructions

12VDC TO 230VAC INVERTERS

Owner s Guide. DC TO AC Power Inverter

Installation and Operating Instructions (for chargers shown below)

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.

Battery Power Inverters

Item no Smart AC 200 USB. User s Manual

Go Power! Manual. GP-SW1500 Inverter. Table of Contents. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4

Pure Sine Wave Inverter User Manual

QPET, QPETXU Battery Chargers

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC A

QSSE, QSSEX INDUSTRIAL Battery Chargers

1200+ WITH LVD (LOW VOLTAGE DISCONNECT) V1.00 OWNERS MANUAL

OWNER S MANUAL. Model YUA2AMPCH 2 AMP Dual-Bank Automatic Battery Charger & Maintainer READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

ELECTRONIC MARINE CONVERTER/CHARGER Owners Manual Models PD2020, PD2030, PD2040, PD2050, PD2060, PD2080

DX100. Owner's Guide Conforms to UL Std Toll Free

OPERATOR'S MANUAL IMPORTANT SAFETY INSTRUCTIONS

Transcription:

IQS300 Series Quasi-Sine Inverter Installation & Operation Manual

INTRODUCTION State of the Art MOSFET technology coupled with unique Soft-Start circuitry guarantees reliable operation. The ON-OFF switch illuminates when AC is present at the outputs to provide positive indication of proper operation. The output is a full 160 or 320 Volts peak (115/230 Vrms) to allow it to handle most applications from sonar monitors to electric drills. Extremely heavy input filtering ensures that no electrical noise will be generated to interfere with autopilots, radios or other devices sharing the same batteries. The transformer type output prevents any spikes or surges that might damage computers or other sensitive equipment. Low voltage shutdown circuitry protects the batteries. Current Limiting and Over Temperature shutdown protect the inverter. Ground Fault Interrupt and Short Circuit Detection protect both the user and inverter. Diagnostic LEDs indicate the cause of any shutdown and show when the unit is overloaded. One standard AC receptacle provides for easy connection. Versions are available to operate from 12, 24 or 32 volt battery systems. As with all of our equipment, the IQS300 Series inverters carry a full three year warranty. IQS300-ip-op Specifications Input Voltages Nominal (ip) 12 24 32 Actual (Vdc) 11 14 22 28 32 38 Input Amps (max) 48 24 16.5 Input Fuse (ATC) 25 x 2 30 25 Output Voltages Nominal (op) 110 220 Actual (Vac) 110 120 220-240 Output Amps (max) 2.6 cont. / 4.0 peak 1.3 cont. / 2.0 peak Output Frequency 60 6 1 Hz 50 6 1 Hz Output Type Quasi-Sine Wave General Efficiency Temp Range Isolation Length Width Height Clearance Material Finish Fastenings Weight > 85% @ maximum output 0 40 C @ maximum output 500 VDC Input to Case, 1500 VDC Input to Output & Output to Case 10.1 in / 25.6 cm 5.25 in / 13.3 cm 4.45 in / 11.4 cm 1.0 in / 2.5 cm Marine Grade Aluminum Black Powder Epoxy 18-8 Stainless Steel 11.0 lb / 5.0 kg Designed and manufactured by: ANALYTIC SYSTEMS WARE (1993) LTD. #207 12448 82 Ave. Surrey, B.C., V3W 3E9, Canada phone (604) 543-7378 fax (604) 543-7354 toll free 800-668-3884 US/Canada email: info@analyticsystems.com; web site: www.analyticsystems.com Revised: Jun 2000 2

Specifications subject to change without notice. 3

IMPORTANT SAFETY INSTRUCTIONS 1) SAVE THESE INSTRUCTIONS This manual contains important safety and operating instructions for inverter. 2) Do not expose inverter to rain or snow. 3) Use of an attachment not recommended or sold by the inverter manufacturer may result in a risk of fire, electric shock, or injury to persons. 4) Do not disassemble inverter; take it to a qualified serviceman when service or repair is required. Incorrect reassembly may result in a risk of electric shock or fire. 5) To reduce risk of electric shock, unplug inverter from outlet before attempting any maintenance or cleaning. Turning off controls will not reduce this risk. 6) Never place inverter directly above battery; gases from battery will corrode and damage marine inverter. 7) Never allow battery acid to drip on inverter when reading gravity or filling battery. GROUNDING AND AC POWER CORD CONNECTION INSTRUCTIONS Inverters should be grounded to reduce risk of electric shock. Inverter is equipped with electric receptacles capable of accepting an equipment-grounding conductor and a grounding plug. DANGER Never alter AC cord or plug provided if it will not fit outlet, have proper cord installed by a qualified electrician. Improper connection can result in a risk of an electric shock. Analytic Systems does not recommend the use of the IQS300 Series Inverters in life support applications where failure or malfunction of this product can be reasonably expected to cause failure of the life support device or to significantly affect its safety or effectiveness. Analytic Systems does not recommend the use of any of its products in direct patient care. Examples of devices considered to be life support devices are neonatal oxygen analyzers, nerve stimulators (whether used for anesthesia, pain relief, or other purposes), autotransfusion devices, blood pumps, defibrillators, arrhythmia detectors and alarms, pacemakers, hemodialysis systems, peritoneal dialysis systems, neonatal ventilator incubators, ventilators for both adults and infants, anesthesia ventilators, and infusion pumps as well as any other devices designated as "critical" by the U.S. FDA. 4

INSTALLATION MOUNTING Mount the unit in a DRY location. Allow at least 1 inch of clearance around the unit for adequate cooling. The case is connected to AC Neutral and AC Ground to meet regulatory requirements and to reduce the possibility of the inverter generating any radio frequency interference. There is 500 VDC of isolation between the DC input and the case. You may need to isolate the case from the mounting surface if it is at a different potential than AC Ground. In a vehicle such as a car, truck or bus, the unit should be mounted or electrically connected to the chassis. However, on a steel tugboat, it may need to be isolated from the hull, and have the AC Ground connected to a different location. This can be done by fastening a ground strap under one of the mounting screws, and scraping the paint from under the screw head to ensure a good electrical contact. CAUTION: Do not mount the unit where explosive gases may accumulate as a slight arc may occur when the power leads are connected, and in the unlikely event of a failure, sparks may be generated inside the unit. POWER CONNECTION The unit is supplied with two 5 foot power cables. This should normally be adequate to connect to a source of power. If you must extend the cable: Use the smallest extension length possible. Use no less than 6 gauge conductors. Splice and solder the joints. Protect the joints with heat shrink tubing. Connect the wires as follows: Red to Positive Black to Negative OUTPUT CONNECTIONS One standard two outlet AC receptacle is provided. Ensure that the total average load connected does not exceed the continuous current rating of the unit. 5

OPERATION Turn the switch on the front of the unit on to energize the outputs. The switch will glow to indicate the presence of AC power at the receptacles. PROBLEM SOLVING If the unit switches off or won t turn on, check the diagnostic LED s. If the Low Input LED is on, check the battery. If the Overheat LED is on, reduce the load and wait a few minutes. The unit will switch itself back on. If this does not work there may not be adequate cooling for the inverter. To correct this either move the unit to a place with better ventillation or direct a stream of cool air over the unit. If neither LED is on, check the fuse. If it is blown, replace it with the appropriate size as shown in the specifications. If the unit still won t work, or the fuse is good, check for the presence of input voltage. If the replacement fuse also blows, unplug all devices connected to the unit and try again. If the fuse blows again, the unit is defective and must be returned for repair. The main cause for the fuse to blow is incorrect hookup to the battery (reversed polarity). This is a feature designed to protect the inverter from such a possibility. If this occurs replace the fuse with the same type and rating and connect the inverter properly. If the fuse continues to blow, the unit is defective and must be returned for repair. If the Ground Fault LED is on, a ground fault has occurred. Turn the unit off and disconnect all loads. Turn the unit on and one at a time connect the loads until the ground fault occurs. Turn the unit off and disconnect the load that caused the ground fault. Have the load checked by a qualified service person to determine and correct the reason for the ground fault. Then and only then is it safe to reconnect the load to the inverter. If the Short Circuit LED is on, a short circuit has occurred. Turn the unit off and disconnect all loads. Turn the unit on and one at a time connect the loads until the short circuit occurs. Turn the unit off and disconnect the load that caused the short circuit. Have the load checked by a qualified service person to determine and correct the reason for the short circuit. Then and only then is it safe to reconnect the load to the inverter. If the Overload LED comes on, the total load of all devices connected to the unit exceeds the maximum output capability. Remove at least one of the devices to reduce the maximum load to acceptable levels. 6

REMOTE CONNECTOR The connector is located on the front of the unit. Note: All switches are electronic (solid state) not mechanical relays. REMOTE CONTROL A remote control panel may be connected to the inverter using a 9-pin D connector which attaches to the front panel of the inverter. The remote control panel and D connector are part of the remote control option. The remote control panel allows the unit to be operated remotely as well as duplicating all the diagnostic indicators and audible alarm. A ground fault or short circuit will be indicated by the standby LED on the 7

remote control panel. 8

This page left intentionally blank. 9

LIMITED WARRANTY The equipment manufactured by Analytic Systems Ware (1993) Ltd. (the Warrantor ) is warranted to be free from defects in workmanship and materials under normal use and service. This warranty is in effect for 3 years from the date of purchase by the user (the Purchaser ). 1. In case any part of the equipment proves to be defective, the Purchaser should do the following: a) Prepare a written statement of the nature of the defect to the best of the Purchasers knowledge, and include the date of purchase, the place of purchase, and the Purchasers name, address and telephone number. b) Call Analytic Systems at 1-800-668-3884 or (604) 543-7378 and request a return material authorization number (RMA). c) Return the defective part or unit along with the statement at the Purchasers expense to the Warrantor; Analytic Systems Ware (1993) Ltd., #207 12448 82nd Ave., Surrey, B.C., V3W 3E9, Canada. 2. If upon the Warrantor s examination the defect proves to be the result of defective material or workmanship, the equipment will be repaired or replaced at the Warrantor s option without charge, and returned to the Purchaser at the Warrantor s expense. 3. No refund of the purchase price will be granted to the Purchaser, unless the Warrantor is unable to remedy the defect after having a reasonable number of opportunities to do so. 4. Warranty service shall be performed only the Warrantor. Any attempt to remedy the defect by anyone else shall render this warranty void. 5. There shall be no warranty for defects or damages caused by faulty installation or hook-up, abuse or misuse of the equipment including exposure to excessive heat, salt or fresh water spray, or water immersion except for equipment specifically stated to be waterproof. 6. No other express warranty is hereby given and there are no warranties which extend beyond those described herein. This warranty is expressly in lieu of any other expressed or implied warranties, including any implied warranty of merchantability, fitness for the ordinary purposes for which such goods are used, or fitness for a particular purpose, or any other obligations on the part of the Warrantor or its employees and representatives. 7. There shall be no responsibility or liability whatsoever on the part of the Warrantor or its employees and representatives for injury to any person or persons, or damage to property, or loss of income or profit, or any other consequential or resulting damage which may be claimed to have been incurred through the use or sale of the equipment, including any possible failure of malfunction of the equipment, or part thereof. 8. The Warrantor assumes no liability for incidental or consequential damages of any kind. 10