Turbine STEP System SIMPLEX OR DUPLEX

Similar documents
SPECIFICATIONS EFFLUENT/SUMP SIMPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

SPECIFICATIONS EFFLUENT/SUMP DUPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

Pump Specifications Series. Pre-assembled Duplex Sewage System 30 x 36, 110 Gallon

Flood Dosed System Worksheet

Pump Specifications 250 Series Submersible Sump / Effluent Pump

Pump Specifications 290 Series 3/4 hp Submersible Effluent Pump

Pump Specifications 280 Series 1/2 hp Submersible Effluent Pump

XFL70 FLOW RATE (LPM) Flow Rate (GPM)

Pump Specifications FL60/FLH60 Series 6/10 hp Submersible Effluent Pump

Pump Specifications FL50 Series 1/2 hp Submersible Effluent Pump

Pump Specifications LE40 Series 4/10 HP Submersible Sewage Pump Pump

OIL SMART PLUG AND PLAY SYSTEM, Model #OSS-100

ON-SITE WASTEWATER PRODUCTS

Pump Specifications. LE50 Series ½ HP Submersible Sewage Pump

Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump

Pump Specifications FL100 Series Submersible Effluent Pump

Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump

XLE50 FLOW RATE (LPM) Flow Rate (GPM)

Pump Specifications LE100-Series 1HP Submersible Sewage Pump

Basins, Floats & Accessories

Pump Specifications. D3648LSG, D3648LSGX Series Omnivore 2HP Duplex Grinder Packages LITERS PER SECOND

INSTALLATION INSTRUCTIONS RECOMMENDED MODELS

NOTE: LEH100-Series high-head pumps require a minimum application of 15' head. Do not use pump in this area use a smaller pump.

PUMP VAULT S.T.E.P. SYSTEM

Accessories, Controls and Package Systems

Consult factory for all other models TO ORDER REPLACEMENT PARTS: PLEASE FURNISH THE FOLLOWING INFORMATION:

PUMP TYPES. Pump Sizing. Dose to Gravity. Pumping to Gravity Distribution. Systems that need a Lift. Distribution Box and Tiered Trenches.

OWNER S MANUAL MODELS 810 & 815 PROGRESSING CAVITY GRINDER PUMPS

Section 200 Page 1 Effective: January 15, 2013 Supersedes: June 1, 2012

Pump Specifications FL150 Series Submersible Effluent Pump

50 Hz Products. Commercial Duty Pumps Heavy Duty Solids Handling Pumps Grinder Pumps Lift Station Accessories. Trusted. Tested. Tough.

OWNER S MANUAL MODELS 7011, 7012 & 7013 SUBMERSIBLE GRINDER UNITS. Safety Instructions. Table of Contents. Owner s Information

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

INLINE 1100 COMPACT, MULTI-PUMP SYSTEM. franklinwater.com

Pump Specifications 405 Series Commercial Drain Pump (High-Temp)

OWNER S MANUAL MODELS 840, 841 & 842 SUBMERSIBLE GRINDER UNITS

INLINE 1100 COMPACT, MULTI-PUMP SYSTEM

Consult factory for all other models TO ORDER REPLACEMENT PARTS: PLEASE FURNISH THE FOLLOWING INFORMATION:

Commercial Sewage & Waste Water Systems

Aqua Green Utility Inc.

Date: Project #: Engineer: Prepared By: Bid Date: 30 psi pressure relief valve 50 psi pressure relief valve 60 psi pressure relief valve

REPLACEMENT PARTS LIST FOR MODELS:

HEAVY DUTY FLAP VALVE PUMPS For Fluids Containing up to Line Size Solids

Date: Project #: Engineer: Prepared By: Bid Date:

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

T Series Pump Guide WEBSTER PUMPS

Pump Specifications. Omnivore 2HP Submersible Grinder Pumps LSG200-SERIES (SINGLE STAGE) LSGX200-SERIES (TWO STAGE)

LITERS PER MINUTE TOTAL HEAD IN FEET TOTAL HEAD IN METERS GALLONS PER MINUTE

Technical Data Sheet PF Series 4" (100 mm) Submersible Effluent Pumps. 1 8-inch (3-mm) bypass orifice (patent pending) to ensure flow

INLINE 1100 STAGED PALLET SYSTEM. franklinwater.com

69 bar (1000 psi) for Metallic Pump Heads 24 bar (350 psi) for Non-metallic Pump Heads

WHR/WHRH and WHRE WASTE HANDLING SUMP PUMPS

50 Hz Products. Your Peace of Mind is Our Top Priority. Utility Pumps. Sump / Effluent Pumps. Sewage Pumps. Grinder Pumps. Specialty Products

OWNER S MANUAL MODELS 7011, 7012 & 7013 SUBMERSIBLE GRINDER UNITS. Table of Contents. Safety Instructions. Owner s Information

G10 Series API bar (350 psi) for Non-metallic Pump Heads. G10 with Cast Iron pump head

Your Premier Pump Choice!

REPLACEMENT PARTS LIST FOR 7011 GRINDER MODELS:

FAIRBANKS FIRE PUMPS JOCKEY PUMP SELECTIONS MODELS 933 & 934

G10 Series API bar (350 psi) for Non-metallic Pump Heads. G10 with Cast Iron pump head

G03 Mono-Block Series

LITERS PER MINUTE GALLONS PER MINUTE

Private Wastewater System Catalog. DSG - La Crosse (800)

SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL

SPD50H/100H. Performance Data SPD100H SPD50H. Wholesale Products Page: Section: Performance Data Dated: April 2002 Supersedes: January 2001

Simplex. Specifications: EasyELECTRIC Factory Prewired Basin Package Stainless Rail with Junction Box. Basin Assemblies

G35 Series API bar (1500 psi) for Metallic Pump Heads. G35 with Stainless Steel pump head and SAE flanges. G35 with Brass pump head

G15 Series API bar (2500 psi) for Metallic Pump Heads. G15 for horizontal installations shown with Stainless Steel pump head.

WHR/WHRH and WHRE WASTE HANDLING SUMP PUMPS

ME3H/ME3F SERIES. Automatic and manual models. Single phase power only 115 or 230 volt.

G25 Series API bar (350 psi) for Non-metallic Pump Heads. G25 with Cast Iron pump head

G20 Series. 24 bar (350 psi) for Non-metallic Pump Heads. G20 Close-coupled with Brass pump head ATEX. G20 Version 5 10/16

Potable Water Submersible Turbine Pumps

PF Series 60-Hz, 4-inch (100-mm) Submersible Effluent Pumps

QWIK JON ULTIMA 203 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

Recirculating Media Filters OWNER'S MANUAL

G03 Series. 24 bar (350 psi) for Non-metallic Pump Heads. G03 Shaft-driven with Stainless Steel pump head

G10 Series API bar (350 psi) for Non-metallic Pump Heads. G10 with Cast Iron pump head

5220 SERIES Z-Cell OWNER'S MANUAL

MODELS 7008, 7009, 7010 SUBMERSIBLE GRINDER UNITS

TO ORDER REPLACEMENT PARTS: PLEASE FURNISH THE FOLLOWING INFORMATION: Model Number. Part Number of Pump. Part Number and Description of part.

HYDROMATIC HE8/HE12/HE20/HE25/ HE30/HE35/HE50 HIGH HEAD FILTERED EFFLUENT

Simplex Jobsite Wired Basin Package Non-Sparking Stainless Rail Non-Sparking, Class I, Group D, Division 1, w/fiberglass Cover

COURSE # 343 UNIT 4: ADVANTEX WASTEWATER TREATMENT SYSTEM. What you will learn in this lesson

F20 Series. Maximum Flow Rate: 1.0 gpm (3.8 l/min) Maximum Pressure: 1500 psi (103 bar) for Metallic Pump Heads

103 bar (1500 psi) for Metallic Pump Heads

OWNER S MANUAL. ZOELLER HAZARDOUS ENVIRONMENT PUMPS (For Class I, Division 1, Groups C & D Applications) Explosion Proof Motors

Access Riser Fits PRO370 and PRO380 Series

SPECIFICATIONS ULTIMAX SUB-SURFACE DIRECTIONAL AERATION SYSTEM

Series MSC Sewage Chopper Pumps

CAUTION PREINSTALLATION CHECKLIST. visit our web site: Your Peace of Mind is Our Top Priority. Section: 6.10.

ISSUE DATE JANUARY 1st, 2008 SECTION 5C 240V 1PHASE W/TCU AND VFD

MODEL 510 THE BASEMENT SENTRY II 12 VOLT DC BACKUP PUMP

HYDROMATIC SPD50H/100H SUBMERSIBLE HIGH HEAD, DOUBLE SEAL EFFLUENT

Accessories. Section Outline

NEW! BOOSTER PUMPS. HBP/HBPS series 4" horizontal booster pumps. booster pumps

GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

Replacement Parts List

12 VOLT DC BATTERY BACKUP PUMP PREINSTALLATION CHECKLIST

Transcription:

3649 Cane Run Road Louisville, KY 211-1961, USA 1-800-928-7867 1-502-778-2731 Fax: 1-502-774-3624 www.clarusenvironmental.com SECTION: C1.20.120 CL0019 0816 Supersedes 1212 Turbine STEP System SIMPLEX OR DUPLEX Designed for simplex and duplex (2 pumps) applications in a single polyethylene pump vault. All components selected to withstand the septic tank environment. Exceptionally large unobstructed area for float placement reduces risk of hang ups. Pipe hangers for suspended applications or flat bottom for setting on tank floor. Over 924 linear feet of 1/16" filtration. Large filter area protects effluent pumps in even the dirtiest septic tank. Deep pleated design is easy to clean. Inlet is available precut from the factory or blank for field customization. FILTER CARTRIDGE Covered by US Patent No. 5,985,139; others pending. Low seated filter cartridge provides more vertical room within the vault, allowing for greater versatility when setting floats. Large selection of effluent turbine pumps. fits in any 18" septic tank opening Custom heights available in 51", 60", 66", 72", 78", 84", 90", 96", 108", and 120". Pumps available in 11, 19, 27, 35, 55 and 85 GPM models with variable cord length, and extended warranties. 1

Prepackaged Systems (unassembled) ½ HP MODEL WITH FLOAT SWITCH CONTROL ½ HP MODEL WITH FLOAT SWITCH CONTROL & ALARM 5041-0003 5041-0004 5041-0005 5041-0006 ½ HP (11 GPM) Package ½ HP HH (11 GPM) Package ½ HP (19 GPM) Package ½ HP (27 GPM) Package Patent No. 5,985,139 5041-0007 5041-0008 5041-0009 5041-0010 ½ HP (11 GPM) w/ Alarm Package ½ HP HH (11 GPM) w/ Alarm Package ½ HP (19 GPM) w/ Alarm Package ½ HP (27 GPM) w/ Alarm Package * * System Includes: Filter and pump chamber. ½ HP effluent rated turbine pump. 115V rated system. Double piggyback float switch control and float tree. 1¼" flexible discharge pipe assembly. System Includes: Filter and pump chamber. ½ HP effluent rated turbine pump. 115V rated system. Double piggyback float switch control and float tree. 1¼" flexible discharge pipe assembly. Indoor/outdoor alarm and float. Note: All on/off alarm settings must comply with all state and local codes. NOTE: Blank tanks are available for field installed inlet hole. NOTE: Blank tanks are available for field installed inlet hole. SK28 * Order prewired conduit, junction box or check valve separately if required. * Order prewired conduit, junction box or check valve separately if required. SK29 ½ HP MODEL WITH SIMPLEX CONTROL PANEL ½ HP MODEL WITH TIMED DOSE PANEL 5041-0011 5041-0012 5041-0013 5041-0014 ½ HP (11 GPM) w/ Simplex Control Package ½ HP HH (11 GPM) w/ Simplex Control Package ½ HP (19 GPM) w/ Simplex Control Package ½ HP (27 GPM) w/ Simplex Control Package 5041-0015 5041-0016 5041-0017 5041-0018 ½ HP (11 GPM) w/ Timed Dosing Package ½ HP HH (11 GPM) w/ Timed Dosing Package ½ HP (19 GPM) w/ Timed Dosing Package ½ HP (27 GPM) w/ Timed Dosing Package * * System Includes: Filter and pump chamber. ½ HP effluent rated turbine pump. 115V rated system. Simplex control and alarm panel. 3 variable level float switches and float tree. 1¼" flexible discharge pipe assembly. NOTE: Blank tanks are available for field installed inlet hole. System Includes: Filter and pump chamber. ½ HP effluent rated turbine pump. 115V rated system. Time dosing single pump control panel. 3 variable level float switches and float tree. 1¼" flexible discharge pipe assembly. Note: It is the responsibility of the installer & designer to assure all state and local codes are met. NOTE: Blank tanks are available for field installed inlet hole. SK2410 SK2411 * Order prewired conduit, junction box or check valve separately if required. * Order prewired conduit, junction box or check valve separately if required. 2

Custom Applications (A) FILTER AND PUMP CHAMBER Patent No. 5,985,139 (C) DISCHARGE ASSEMBLIES & CHECK VALVES Includes filter pack with handle and pump chamber preassembled at factory. 5041-0034 51" Field Cut 5041-0001 60" Factory Cut 5041-0025 66" Field Cut 5041-0026 72" Field Cut 5041-0027 78" Field Cut 5041-0028 84" Field Cut 5041-0029 90" Field Cut 5041-0030 96" Field Cut 5041-0056 108" Field Cut 5041-0049 120" Field Cut (B) TURBINE EFFLUENT PUMPS 11 GPM Turbine Effluent Pump - 1.25 Discharge 5030-0005.5 Hp, 115V/1Ph, 12 Amp, 5-Stage, 10 cd 5030-0006.5 Hp, 230V/1Ph, 6 Amp, 5-Stage, 10 cd 5030-0007.5 Hp, 115V/1Ph, 12 Amp, 7-Stage, 10 cd 5030-0008.5 Hp, 230V/1Ph, 6 Amp, 7-Stage, 10 cd 5030-0009.75 Hp, 230V/1Ph, 8 Amp, 10-Stage, 10 cd 5030-0012 1 Hp, 230V/1Ph, 9.8 Amp, 13-Stage, 10 cd 19 GPM Turbine Effluent Pump - 1.25 Discharge 5031-0005.5 Hp, 115V/1Ph, 12 Amp, 5-Stage, 10 cd 5031-0006.5 Hp, 230V/1Ph, 6 Amp, 5-Stage, 10 cd 5031-0007.75 Hp, 230V/1Ph, 8 Amp, 7-Stage, 10 cd 5031-0008 1 Hp, 230V/1Ph, 9.8 Amp, 9-Stage, 10 cd 27 GPM Turbine Effluent Pump - 1.25 Discharge 5032-0005.5 Hp, 115V/1Ph, 12 Amp, 4-Stage, 10 cd 5032-0006.5 Hp, 230V/1Ph, 6 Amp, 4-Stage, 10 cd 5032-0007.75 Hp, 230V/1Ph, 8 Amp, 6-Stage, 10 cd 5032-0008 1 Hp, 230V/1Ph, 9.8 Amp, 7-Stage, 10 cd 5032-0009 1.5 Hp, 230V/1Ph, 13.1 Amp, 10-Stage, 10 cd 35 GPM Turbine Effluent Pump - 2 Discharge 5033-0005.5 Hp, 115V/1Ph, 12 Amp, 2-Stage, 10 cd 5033-0006.5 Hp, 230V/1Ph, 6 Amp, 2-Stage, 10 cd 5033-0007.75 Hp, 230V/1Ph, 8 Amp, 3-Stage, 10 cd 5033-0008 1 Hp, 230V/1Ph, 9.8 Amp, 4-Stage, 10 cd 5033-0009 1.5 Hp, 230V/1Ph, 13.1 Amp, 5-Stage, 10 cd 55 GPM Turbine Effluent Pump - 2 Discharge 5034-0005.5 Hp, 115V/1Ph, 12 Amp, 1-Stage, 10 cd 5034-0006.5 Hp, 230V/1Ph, 6 Amp, 1-Stage, 10 cd 5034-0007.75 Hp, 230V/1Ph, 8 Amp, 2-Stage, 10 cd 5034-0008 1 Hp, 230V/1Ph, 9.8 Amp, 3-Stage, 10 cd 5034-0009 1.5 Hp, 230V/1Ph, 13.1 Amp, 4-Stage, 10 cd 5034-0010 2 Hp, 230V/1Ph, 13.2 Amp, 5-Stage, 25 cd 5034-0011 3 Hp, 230V/1Ph, 14.5 Amp, 7-Stage, 25 cd 85 GPM Turbine Effluent Pump - 2 Discharge 5035-0005.75 Hp, 230V/1Ph, 8 Amp, 1-Stage, 10 cd 5035-0006 1 Hp, 230V/1Ph, 9.8 Amp, 2-Stage, 10 cd 5035-0007 1.5 Hp, 230V/1Ph, 13.1 Amp, 3-Stage, 10 cd 5035-0008 2 Hp, 230V/1Ph, 13.2 Amp, 4-Stage, 25 cd 5035-0009 3 Hp, 230V/1Ph, 14.5 Amp, 6-Stage, 25 cd Turbine Effluent Pump Extended Warranties 021392.5-1.5 Hp, 5-Year Extended Warranty 021393 2-3 Hp, 5-Year Extended Warranty SK2413 11, 19, 27 GPM Models 35 GPM Models NOTE: Turbine effluent pumps are available with 25', 50', and 100' cord lengths. Discharge pipe assembly consists of a male adapter, PVC piping, elbows, PVC pipe, union/ball valve, pipe seal, and stub to extend outside of riser. Preassembled and welded at the factory. Flexible Discharge Assemblies for Simplex Systems 170-0158 1" SCH PVC (185' TDH Max.) 170-0172 1" SCH PVC for 96" system (185' TDH Max.) 170-0082 1 ¼" SCH PVC (185' TDH Max.) 170-0174 1 ¼" SCH PVC for 96" system (185' TDH Max.) 170-0148 1 ¼" SCH PVC (185' TDH Max.) 170-0159 2" SCH PVC (130' TDH Max.) 170-0161 2" SCH PVC for 96" system (130' TDH Max.) 170-0178 2" SCH PVC for 120" system (130' TDH Max.) Rigid Discharge Assemblies for Simplex Systems 170-0181 1" SCH PVC 170-0182 1 ¼" SCH PVC 170-0184 1 ¼" SCH PVC for 96" system 170-0186 1 ¼" SCH PVC for 120" system 170-0183 2" SCH PVC 170-0190 2" SCH PVC for 84" system 170-0185 2" SCH PVC for 96" system 170-0187 2" SCH PVC for 120" system 170-0177 2" SCH PVC 3' cold weather extension kit Rigid Discharge Assemblies for Duplex Systems 170-0197 1 ¼" SCH PVC, dual discharge 170-0195 2" SCH PVC, dual discharge 170-0206 2" SCH PVC, 3' cold weather extension kit, dual discharge Check Valves 30-0187 1 ¼" brass threaded check valve 30-0189 2" brass threaded check valve Discharge Assembly SK2049 3

Custom Applications, continued (D) CONTROL/ALARM Double Piggyback Variable Level Pump Control Switches 10-1966 115V, 13 Amps (7" max. pumping range) 10-1967 230V, 13 Amps (7" max. pumping range) High Water Alarm Assembly 10-12 Indoor Alarm assembly 10-0623 Outdoor Alarm assembly, NEMA 3R with 15' mechanical switch 10-3067 C-Pak Alarm, Touch Panel, NEMA 4X, w/o float Demand Dose Control Panels Simplex panel with pull out disconnect, motor contactor, and high water alarm circuit. 10-1355 Simplex panel, NEMA 4X, 115/230V, 1 phase, 0-20 Amps, 3 mechanical float switches 10-0093 Duplex panel, NEMA 4X, 115/230V, 1 phase, 0-20 Amps, 3 mechanical float switches Timed Dose Control Panels (includes float switches) Timed dose panel for single pump control with alarm circuit, elapsed time meter, event counter, circuit breaker, motor contactor, and float switches (see FM1559). 10-1021 Simplex panel, NEMA 4X, 115V, 0-20 Amps, 1 phase, 2 float switches 10-0684 Simplex panel, NEMA 4X, 115V, 0-20 Amps, 1 phase, 3 float switches 10-0697 Simplex panel, NEMA 4X, 230V, 0-20 Amps, 1 phase, 3 float switches 10-1430 Duplex panel, NEMA 4X, 115/230V, 0-20 Amps, 1 phase, 3 float switches Note: All variable level float switches in this section are mechanically activated and do not contain mercury. (E) PREWIRED CONDUIT/JUNCTION BOX Prewired conduit is designed to make the electrical wiring easier. Assemblies come with the correct numbers of wires of the correct gauge for the application. Junction box is included. For Simplex Demand or Timed Dose Control Panels (up to 3 floats) - ½" Conduit 5100-0001 25' long w/ J-Box (4 cord seals, 1 plug) wt. 10 lbs. 5100-0002 35' long w/ J-Box (4 cord seals, 1 plug) wt. 14 lbs. 5100-0003 50' long w/ J-Box (4 cord seals, 1 plug) wt. 18 lbs. 5100-0004 75' long w/ J-Box (4 cord seals, 1 plug) wt. 26 lbs. 5100-0005 100' long w/ J-Box (4 cord seals, 1 plug) wt. 33 lbs. For Duplex Demand or Timed Dose Control Panels (up to 3 floats) - ¾" Conduit 5100-0026 25' long w/ J-Box (5 cord seals, 1 plug) wt. 10 lbs. 5100-0027 35' long w/ J-Box (5 cord seals, 1 plug) wt. 14 lbs. 5100-0028 50' long w/ J-Box (5 cord seals, 1 plug) wt. 18 lbs. 5100-0029 75' long w/ J-Box (5 cord seals, 1 plug) wt. 26 lbs. 5100-0030 100' long w/ J-Box (5 cord seals, 1 plug) wt. 33 lbs. NEMA 4X Junction Boxes Select Junction Box based on number of cords present in riser. 10-1399 4"L x 4"W x 4"H, 4 round cord seals, 1½" hub (assembled), wt. 1.0 lb. 10-0777 4"L x 4"W x 2"H, 4 round cord seals, ¾" hub (assembled), wt. 1.0 lb. 10-0778 4"L x 4"W x 2"H, 5 round cord seals, ¾" hub (assembled), wt. 1.0 lb. (F) FLOAT TREE Float trees are selected based on the number of float switches in each assembly. 10-1672 2 - Hanger Float Tree (for use with 2-float applications) 10-1673 3 - Hanger Float Tree (for use with 3-float applications) 10-1674 4 - Hanger Float Tree (for use with 4-float applications) 10-1726 5 - Hanger Float Tree (for use with 5-float applications) Adders are available for 72", 84", 96", 108", and 120" float tree lengths. Floats ordered separately, also may be included with panels. SK2412 Clarus Turbine STEP System has 6 basic components: (A) Filter and pump chamber (B) Pump (C) Discharge Assembly (D) Control/Alarm System (E) Prewired Conduit /Junction Box (F) Float Tree 4

Turbine STEP System Performance TOTAL DYNAMIC HEAD METERS FEET PUMP PERFORMANCE CURVE 11 GPM 1 1/4" NPT DISCHARGE 160 520 152 144 480 136 128 4 120 0 112 104 360 96 320 88 80 72 64 56 48 32 24 280 2 200 160 120 80 16 8 0 GALLONS 2 4 6 8 10 12 14 16 18 LITERS 0 8 16 24 32 48 56 64 FLOW PER MINUTE 015413A 1 HP - 13 STAGE 3/4 HP- 10 STAGE 1/2 HP- 7 STAGE 1/2 HP- 5 STAGE 015414A 5

Turbine STEP System Performance, continued 96 FEET METERS 320 PUMP PERFORMANCE CURVE 27 GPM 1 1/4" NPT DISCHARGE 1 1/2 HP- 10 STAGE 88 80 300 280 260 TOTAL DYNAMIC HEAD 72 64 56 48 2 220 200 180 160 1 120 1 HP- 7 STAGE 3/4 HP 6 STAGE 1/2 HP- 4 STAGE 32 100 24 80 16 8 60 20 0 GALLONS 5 10 15 20 25 30 35 LITERS 0 20 60 80 100 120 1 FLOW PER MINUTE 015045A 015044A 6

Turbine STEP System Performance, continued METERS FEET 75 250 70 225 65 60 200 3 HP-7 STAGE PUMP PERFORMANCE CURVE 55 GPM 2" NPT DISCHARGE 55 50 175 2 HP-5 STAGE TOTAL DYNAMIC HEAD 45 35 30 150 125 100 1.5 HP-4 STAGE 1 HP-3 STAGE 25 20 75 3/4 HP-2 STAGE 15 10 5 50 25 1/2 HP-1 STAGE 0 10 20 30 50 60 70 80 90 100 GALLONS LITERS 0 80 120 160 200 2 280 320 360 FLOW PER MINUTE 015845A TOTAL DYNAMIC HEAD METERS FEET 60 200 55 175 50 45 150 125 35 30 100 PUMP PERFORMANCE CURVE 85 GPM 2" NPT DISCHARGE 3 HP-6 STAGE 2 HP-4 STAGE 1.5 HP 3 STAGE 25 20 15 10 5 75 50 25 1 HP-2 STAGE 3/4 HP-1 STAGE 0 20 60 80 100 120 1 GALLONS LITERS 0 80 160 2 320 0 480 FLOW PER MINUTE 015649A 7

Turbine STEP System Specifications 4" 17 7 8 " 60" 17 3 8 " 22 1 2 " 18 3 8 " 2 1 4 " 60" STANDARD VAULT SK2396 Materials of Construction Tank Polyethylene Filter Cartridge Polypropylene / PVC Float Tree PVC Hanger Pipe PVC Drain Valve Neoprene / Stainless Steel Your Peace of Mind is Our Top Priority 3649 Cane Run Rd. Louisville, KY 211-1961 (502) 778-2731 FAX: (502) 774-3624 www.clarusenvironmental.com Copyright 2012. All rights reserved.