OWNERS MANUAL ECODIVER

Similar documents
IT GB F D E NL SF P S RUS CZ SI SK HR SCG

GB INSTRUCTIONS MANUAL

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

77014 / Automatic Users Manual. Carefully read this entire Instruction Manual before using this product

SUBMERSIBLE PUMPS HSE RANGE OPERATING & MAINTENANCE INSTRUCTIONS GC0514

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

SUBMERSIBLE WATER PUMP

SUBMERSIBLE PUMP HSE RANGE

SUBMERSIBLE WATER PUMP

DRENOX SUBMERSIBLE SUMP PUMPS FOR DRAINING CLEAR WATER. Usage limitations

Matala. VersiFlow Series. Instruction and Maintenance Manual

OWNER S MANUAL CLEAR ANSWER SOLID ANSWER

SUBMERSIBLE WATER PUMPS

SUBMERSIBLE WATER PUMP

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

OPERATION & MAINTENANCE INSTRUCTIONS

OPERATION & MAINTENANCE INSTRUCTIONS

SUBMERSIBLE WATER PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model Nos. CSE400A. Part No iss 2

1/2 HP SUMP PUMP OWNER'S MANUAL

SUBMERSIBLE DIRTY WATER PUMP

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

garden PUMP kit 1 Depth A & B must be less than 9m Max Depth C must be less than 9m Max GardenPump Inst 6/11/07 12:52 Page 1

SUBMERSIBLE PUMP HSE RANGE

June14. Type

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

Installation and Operating Instructions for Davey HS20-65Y2 Multistage Pump

250W PUDDLE PUMP WITH AUTO SENSOR MODEL NO: PSP105

AUTOMATIC SUBMERSIBLE UTILITY PUMP

Submersible Pump Instructions. Safety Instructions

SUBMERSIBLE PUMP 400 WATTS, WITH FLOAT Model 45019

Submersible Effluent Pump

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

SUBMERSIBLE SUMP PUMPS

StormPro BA Series Sump Pump

DIVERTRON DATI GENERALI GENERAL DATA. motralec POMPA MULTIGIRANTE MULTI-IMPELLER PUMP DATI TECNICI / TECHNICAL DATA

SUBMERSIBLE SUMP PUMPS

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual WALRUS PUMP CO., LTD. ISO 9001 Certified NSF/ANSI 372

GeyserMax-Flow Series

Bore Hole Pump Model Nos: CBB75 CBB100 Part Nos:

Domestic Water Supply Pressure Pumps

DRENOX IT - ISTRUZIONI ORIGINALI IN LINGUA ITALIANA

TS Series. MultiStage Centrifugal Pump Instruction Manual. Walrus America Inc. ISO 9001 Certified

ELECTRIC LIFTING HOIST

OWNER S MANUAL. Submersible Sump Pumps Models: XQS33 (1/3 HP Sump Pump) XQS50 (1/2 HP Sump Pump) Suzhou Xin Qi Electric Co.,ltd

StormPro BCV400 Sewage Ejector Pump

Owners Manual: - Pumps

Installation & Operating Manual

Installation Manual. Omnivore Grinder Pump Retrofit Unit LSG202-RE. LSGX202-RE 2Hp, V, 1 phase, Automatic LSG202-REX

Operating Manual Includes Pumps: PG-9000 Part #R809606

GARDEN HOSE UTILITY PUMP

Anleitung_BG_PW_48_SPK1:_ :33 Uhr Seite 1. Operating Instructions Petrol Water Pump. Art.-Nr.: I.-Nr.

OWNER S MANUAL. Evolution Series Fountain. 1/2 hp, 115V, 60 Hz

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

OPERATION MANUAL SUBMERSIBLE FOUNTAIN PUMP PM2 600LV PM2 900LV PM2 1500LV PM2 2400LV PM2 4500LV

MODEL P INSTALLATION INSTRUCTIONS

ESE Series Cast Iron Sewage Pumps

SIP Direct Drive Oil-Lube Air Compressors - Operating & Maintenance Instructions

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

EBARA COMPACT BOOSTER AM-PC

Submersible Pump BIA-B10A BIA-B15A BIA-B25A BIA-B40A BIA-B42A BIA-B15VA BIA-B25VA BIA-B40VA BIA-B75A BIA-B75VA BIA-B75KA BIA-B120G

DIAPHRAGM PUMPS: Instruction Manual

Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

BIOXDPV 160/6 IT - ISTRUZIONI ORIGINALI IN LINGUA ITALIANA

Installation, Operation and Maintenance Manual Stancor SE, SV, SS & SC Series Pumps

Installation and Operating Instructions for Davey HP, HS & HM Pressure Systems with Presscontrol

IP 900 W/KS & IP 900 D/KS

Unilift KP 150, KP 250, KP 350

MP V 8A Electronic Smart Charger. Instruction and Information Manual

MODEL INSTALLATION INSTRUCTIONS. 12 Volt UTILITY PUMP

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps

Trouble Shooting Guide EWA, 3-phase (D2422)

MINIPOND 700/900 Mk2 THE POND MASTERS GUIDE TO. Blagdon - The Pond Masters The name you can rely on

Installation and Operating Instructions for Davey HM Series Pressure Systems with Pressure Switch

INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE (GB)

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

TPHK Series Immersible Pump

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions

Submersible Tank Pump

Sump Pump. Installation and Operating Instructions

Instruction Manual. * We reserve the right to amend specification without prior notice.

SUNC3000 / Item #40885

230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230

D-Series Blowers and Exhausters

HOME CHARGER MODE 2. Series to /32A single phase CONTENTS. Manual IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY INFORMATION 4 INSTALLATION 5

User s Manual D-Series Blowers and Exhausters

MODEL H INSTALLATION INSTRUCTIONS

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

Installation and Operating Instructions for Davey HS20-65Y2T Multistage Pressure System with

SuperFlo 9,000 High Volume Pump Product Manual

SUPER PUMP OUT SYSTEM

INSTALLATION & OPERATION MANUAL

Installation manual wall-mounted distributor

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

Ion Technologies WC33 Submersible Sump Pump

US - UP2/OIL 12V US - UP2/OIL 24V

This manual presents installation, servicing, troubleshooting, and maintenance for M PUMPS CM MAG-M SERIES Information that may be required regarding

Mod: KLD6-12/35XLAS-N

5.5KVA GENERATOR MODEL NO: PG6500DVES OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0616

Submersible Mixed Flow/Axial Flow Pump Model SAM Model SPM

Transcription:

OWNERS MANUAL ECODIVER

ECO-DIVER Powerful multistage submersible pumps ideal for rain water systems, operating sprinklers, pumping water from tanks, cisterns, ponds and wells and other applications that require high pressure. Available with 2, 3 or 4 impellers. Suitable for pumping clear water. 1) SAFETY MEASURES Before starting the pump, read this Instruction booklet carefully. For safety reasons, the pump must not be used by anyone who has not read these instructions. The pump must not be used by anyone under 16 years of age; keep children well away from the pump when in operation. The power cord and floating switch must never be used to carry or move the pump. Always use the pump s handle. When handling the pump, while it is connected to the electric power supply, you should avoid all contact with water. Never remove the plug by pulling on the power cord. Before taking any action on the pump, always remove the plug from the power socket. If the power supply cord has been damaged, it must be replaced by the manufacturer or his authorized customer support service in order to avoid all risks. Overload protection The pump has a thermal overload safety device, In the event of any overheating of the motor, this device automatically switches off the pump. The cooling time is roughly 15 to 20 minutes, and then the pump automatically comes on again. If the overload cutout is tripped, it is essential to identify and deal with me cause of the overheating. See Troubleshooting.

2) USE Basic submersible pumps; ready for use pumps designed for the emptying of basements, garages and other flooded locations. The pump must only be used in clean or slightly dirty water. > Equipped with a floating switch for automatic stop and start > Delivery with 3 different types of connection > Suction filter. These pumps are maintenance free. The submersible pumps - with float - are not suitable for continuous working. Multipurpose submersible pumps for drainage, emptying, transfer and for smallscale Irrigation needs both in the clean water version as well as the dirty water version. Available both in the automatic version with floating switch to automatically switch the pump on and off, and in the manual version. Submersible pumps suitable for pumping clean water containing small solid particles with a maximum diameter of 5 mm. Submersible pumps suitable for pumping dirty water containing solid particles with a maximum diameter of 30 mm. Powerful submersible pump suitable for pumping dirty water containing solid particles with a maximum diameter of 38 mm. The pumps have not been designed for continuous working Submersible pumps for garden ponds to create water falls and fountains. The pumps are designed to pump clean water or water containing solids with a diameter from 5 to 10 mm (depending on the regulation of the filter). > Ideal for continuous use > Designed for horizontal or vertical installation. Multi-impeller submersible pumps with 2, 3 or 4 impellers: ideal for rain water and mains irrigation systems, for pumping water from tanks, ponds and wells and other applications that require high pressure. The multistage submersible pumps must only be used in clean water. The pump should ideally be completely submersed for it to operate correctly, but can be used at a minimum suction height of 50 mm for very short periods. Available both in the automatic version with floating switch to automatically switch the pump on and off, and in the manual version.

Characteristics: > Optimum motor cooling that allows the pump to be used also when it is only partially submersed. > Stainless steel anti-deposit filter > Non return valve and 4-way connector. Multipurpose submersible pumps designed specifically for use in saltwater. Equipped with: > Anti-oxidation and anti-corrosion materials > AIS! 316 stainless steel motor casing, drive shaft and belts. The temperature of the fluid being pumped must never exceed 35 C. The pump must not be used to pump salt water (unless specifically designed for the purpose), sewage {except for submersible pumps suitable for pumping dirty water with solid particles having a maximum diameter of 38 mm), flammable, corrosive or explosive liquids (e.g. petroleum oil, petrol, thinners), grease, oils or foodstuffs. Comply with the rules and regulations of the local water authority when using the pump for the supply of domestic water. 3) STARTING THE PUMP Before starting the pump make sure that: The voltage and frequency specified on the pumps nameplate coincide with those of the available power supply: There are no signs of damage to the pump or its power cord; The electric connection is made in a dry place. Protected against any risk of flooding; The electric system is complete with e residual current circuit breaker (I An 30 am) and an efficient earthing connection; Any extension cords must comply with the requirements of the DIN VDE standard 0620. Note: given the different provisions applicable to the safety of electric systems in different countries, make sure that the pump system, as concerns its intended use, is in accordance with current legislation.

Insert the plug of the power cable into a suitable power socket. Automatic operation: The floating switch starts and stops the pump automatically. The water level that prompts the starting and stopping of the pump can be adjusted by changing the length of cable of the float between the holder and the float. N.B. The length of the float cable must never be shorter than 10 cm. Manual operation: a) The floating switch must be lifted in order to start pumps with a float. b) For pumps without a float, insert the plug. 4) RECOMMENDATIONS To ensure the proper operation of the pump, it is important to comply with the following recommendations: The pump must never he allowed to run dry. Never leave the pump in operation when the delivery pipe is clogged. The pump must only be used when it is immersed in water. If the water runs out, the pump must be stopped immediately by removing the plug from the power supply. Pay careful attention when the pump is operated in manual mode. The pump must be placed in a stable position inside a trap or in the lowest part of the place where it is installed. The float must be able to move freely while the pump is running therefore the advised dimensions of the trap are 40x40cm. Periodically, it is advisable to make sure that no dirt (leaves, sand, etc.) has accumulated in the collection trap. MAINTENANCE AND CLEANING It is absolutely essential to prevent any risk of the pump freezing. In the event of freezing temperatures, remove the pump from the liquid, empty it and keep it in a place where it cannot freeze. The pump must be disconnected from the mains power supply before any cleaning operation is performed. The pump is maintenance free.

5) TROUBLE SHOOTING OPERATING INSTRUCTIONS FAULT POSSIBLE CAUSE SOLUTION The motor does not start or makes no noise. A) Make sure the motor is powered. B) The pump is not enabled by the float. B) - Make sure the float can move freely. - Increase the size of the pit. The pump delivers no water. The pump does not stop The flow rate is too low. The pump stops running (possible intervention of the thermal overload switch). A) The suction grid or piping is clogged. B) The impeller is worn or stuck. C) The required head is too high for the characteristics of the pump. D) Water level under the suction minimum. A) The pump is not disabled by the float. A) Make sure the suction grid is not partially clogged. B) Make sure the impeller or delivery pipe are not partially clogged or fouled -Make sure the fluid being pumped is not too dense, causing the motor to overheat. - Make sure the temperature of the water is not too high. - Make sure there is no solid body obstructing the impeller. - Power supply doesn t comply with the name plate s data. A) Remove the obstruction. B) Replace the impeller or remove the obstruction. A) Make sure the float can move freely. A) Remove any obstructions. B) Remove any obstructions. Disconnect the power cord, correct the reason for overheating; then wait until the pump is cooled, plug the cord and resume operation. 6) DISPOSAL This product or its parts must be disposed of in accordance with the laws regarding the environment; Use the local, public or private, refuse collection services, 7) GUARANTEE Any material or manufacturing defects will be corrected during the guarantee period established by current law in the country where the product is purchased, it is up lo the manufacturer to decide whether to repair or replace any faulty parts. The manufacturers guarantee covers all substantial detects attributable to manufacturing or material defects, providing the product has been used correctly and in compliance with the instructions.

The guarantee becomes null and void in the event oft he following: Unauthorized attempts to repair the appliance; Unauthorized technical changes to the appliance; Use of non-original spare parts; manhandling; Inappropriate use, e.g., for industrial purposes. The guarantee does not cover: Parts liable to rapid wear and tear, For any action under guarantee, contact an authorized customer support service, presenting your receipt for the purchase of the product. The manufacturer accepts no liability for any inaccuracies in the present booklet due to printing or copying errors. The manufacturer reserves the right to make any changes to the product he deems necessary or useful, without affecting its essential features.. 8) APPROVAL AND CONFORMITY MARKS

3226 BENCHMARK DRIVE LADSON, SC 29456 USA TEL: 1-843-824-6332 FAX: 1-843-797-3366