Operating Manual Model- P282 Digiflow Controller

Similar documents
Flow Meters & Instruments. Insertion Paddle Wheel & Magnetic Flow Meters Flow & Anaytical Instruments. Technical Catalogue

Appendix. Clearance. Skewed profiles. Application Schematics

Insertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT

digital flow meters BW Digi-Meter F-1000

BI-DIRECTIONAL INSERTION FLOW TRANSDUCER

F-2700 SERIES INSERTION VORTEX FLOW METER

Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller for On/Off control

F-1500 SERIES INSERTION TURBINE FLOW METER

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

RCM - Direct Reading Flowmeters

Positive Displacement Flowmeters GM020 series instruction manual

OM SERIES OVAL GEAR METERS. OM SERIES Oval Gear Meters

Positive displacement batch controller

SIGNET 7002 Vortex Flow Sensor ENGLISH

INSERTION flow sensor for continuous flow measurement

FLOWX3 F3.20 High Pressure Paddlewheel Flow Sensor MAIN FEATURES APPLICATIONS OPERATING PRINCIPLE

Low Profile Insertion Vortex

PSF50 Paddle flow switch

BI-DIRECTIONAL INSERTION METER

F-2600 SERIES INLINE VORTEX FLOW METER

MX-SERIES OVAL GEAR FLOW METERS

RUN ACCUM. TOTAL STOP BAT LOW HIGH

Electromagnetic Flowmeters. Product Overview.

For any information please contact: ASCO Pompe srl Control Division Tel.: (+39 02) (switchboard) Fax: (+39 02)

Inline Ultrasonic Flowmeter

Liquid Turbine Flow Meter OwnerÊs Manual

F-2700 SERIES INSERTION VORTEX FLOW METER

PMG MAGNETIC FLOWMETER

Positive displacement flowmeter for continuous flow measurement

Octave Water Meter Installation Manual

ISTEC MAGNETIC METERS

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

WATER METERS OCTAVE ULTRASONIC WATER METER INSTALLATION & USER GUIDE

Hot Tap Insertion Vortex

Flowmeters & Monitors

OMP POSITIVE DISPLACEMENT FLOWMETERS

RPFS. ROTA PULSE FLOW SENSOR (Slip Insertion Paddlewheel) DATASHEET FEATURES

ECONOMISER SERIES E2T USER MANUAL

flow x3 flow monitoring

FIRE HYDRANT/HOSEREEL PORTABLE TESTER

Paddle-wheel flow controller with optical principle for On/Off control

Range of Ultrasonic Flowmeters.

FPD1001 thru FPD1003, FPD1102 and FPD1103, FPD1201 thru FPD1203 (includes -R Option) Positive Displacement Flowmeters

ROTA PULSE FLOW SENSOR Slip Insertion Paddlewheel (with inductive coil pulse output & built in op-amp circuit)

OMP Positive Displacement Flowmeters

macnaught flow measurement

Model FVP General Specification. Flanged Vortex Plate. Product Features

INSERTION flowmeter with paddle wheel, ELEMENT design

SS3 Linear / Rotary. Smart Valve Positioner. Smart performance with innovative and ever-strong coil drive even under harsh working environments

DOR INSERTION PADDLE WHEEL FLOWMETER

EM 101 EM EM EM GENERAL INFORMATION. SPECIFICATIONS MATERIALS Wetted Materials - FLOW RANGE

SSI Technologies Application Note PS-AN7 MediaGauge (Model MG-MD) Digital Pressure Gauge Product Overview

VIM20 Vortex Insertion Flowmeter

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

macnaught flow measurement

RIM20 Rotor Insertion Flowmeter

M Series. Feature rich flow meter and switch with in-line. flow

VIM20 Vortex Insertion Flowmeter

Model 1000 Vortex Meter

Sidel Therm & CO 2 Counter Instruction & Installation Manual

Multivariable Vortex Flow Meter

IP800-Series. Insertion Paddlewheel Flow Sensor Instructions PROUDLY MADE IN THE USA

RESISTIVITY MONITOR/CONTROLLERS

Insertion magnetic inductive flowmeter

POSITIVE DISPLACEMENT FLOWMETER

Figure 1: WPR2 Dimensions and Hardware

Iron Gate Air Pump System Manual

DIGIFLO ELECTRONIC FLOWMETER

Vortex In Line Flow Meter

Model TUR-200D Turbine Flowmeter

TEK-F LUX 1400A. Electromagnetic Flowmeter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW

VORTEX IN-LINE FLOW METERS

Ultrasonic Flowmeter. M-1500 Plus Non-invasive Inline DSP Ultrasonic Flowmeter. Operating Principle. Features

2100 Turbine Flow Sensor

LTX RF LEVEL SENSOR. Instruction Manual

IP80-Series FLOW SENSOR INSTRUCTIONS IP81 IP :2008 ISO CERTIFIED COMPANY IP80-SERIES FLOW SENSOR INSTRUCTIONS

ProMinent delta Solenoid Diaphragm Metering Pumps

Distributed by: M&M Control Service, Inc MICRO-FLO MICRO-FLO

IP800-Series. Insertion Paddlewheel Flow Sensor Instructions PROUDLY MADE IN THE USA

Signet 7000/7001 Vortex Flow Sensors * *

TURBINE METERS - WP Series

FLEX-PRO TM PERISTALTIC PUMPS

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

Ultrasonic Flow Meter Series Smart-IN US. Features. Description

OM004, OM006 & OM008 Oval Gear Meter

Vortex Plate. Model VP General Specification. Product Features

Application Engineering

HUMIDITY / TEMPERATURE TRANSMITTER

Electromagnetic Flow Monitor magphant

Positive displacement flowmeter

Vortex In Line Flow Meter

Sanitary Sensors. High Quality, Precision. Sanitary Sensors. THORNTON Leading Pure Water Analytics

F-2600 SERIES INLINE VORTEX FLOW METER

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

IM012E (ELECTRONIC) POSITIVE DISPLACEMENT FLOWMETER INSTRUCTION MANUAL

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

MULTI FUNCTIONAL COUNT CHECKER MODEL Poka Patrol CNA-4mk3

Transcription:

Operating Manual Model- P282 Digiflow Controller Totalizer mode Controller 00.00 LPH 0000000.0 L t s SET SCL ENT Model- P282 Tecnical specification of flow sensor P812 Flow Rate Range : 0.5 to 5 m/s (1.6 to 16.4 ft./s) Pipe Size Range : 15 NB to 300 NB (0.5 to 12 in.) Linearity : ±1% of full range Repeatability : ±0.5% of full range Authorised Dealer NK Instruments Pvt. Ltd. B-501/504, 5th floor, Raunak Arcade, Near THC Hospital, Gokhale Road, Naupada, Thane(W) 400602. Maharashtra INDIA Telefax Nos.: 91-22-25301330 / 31 / 32 E-Mail: sales@nkinstruments.com Web: http://www.nkinstruments.com Skype: nitinkelkarskype Gtalk: nkinstruments2006

Min. Reynolds Number Required: 4500 Wetted Parts Sensor Body : Polypropylene (black) or PVDF (black) SS 304 / Ss316 / SS316L O-rings : Viton / Teflon Rotor Pin : Hastelly C Rotor : Black PVDF. Frequency : 38 Hz per m/s nominal Supply voltage : 10 to 12 VDC regulated Supply current : <20 ma @ 10 to 24 VDC Output Type : Open collector transistor, sinking Output Current: 10 ma max. Cable Type : 19/38 tefoln two core with shield Cable Length : 5 m (16.4 ft.) Standard Protection Rating : IP 67 Operating Pressure : PP: max10 bar(145 psi) @ 25 C PVDF: max12 bar(175 psi) @ 25 C Operating Temperature: PP: -10 C to 70 C (14 F to 158 F) PVDF: -10 C to 100 C (14 F to 212 F) 2

Line Size selection chart Line Size ( NB ) 15 25 40 50 65 80 100 Min. Flow ( m3/ hr) 0.26 0.88 2.04 3.50 6.30 8.0 14.0 Max. Flow ( m3/ hr ) 2.60 8.80 20.4 35.0 63.0 80.0 140 Fitting Installation Condition All type of flow meter requires straight run, as per site condition following straight pipe lengths must be provided for best result. Sensor Mounting position & Installation 1) For Horizontal pipe line for best performance sensor mount in the upright position. 2) For Vertical pipe line sensor mount in any orientation, Upward flow is preferred to ensure full pipe. 3) Lubricate the sensor O-ring with a silicon gress. 4) Insert the sensor into the fitting, making sure the arrows mark on the black Gatu are pointing in the direction of flow, for field mounting unit sensor must be mounted such that the display becomes parallel to the pipe line. Flow direction Black Gatu Top View of Pipe 3

5) Engage one thread of the sensor cap then turn the sensor until the alignment Pine is seated in the fitting groove. Hand tighten the sensor cap. DO NOT use wrenches or any other tools for tightening the sensor cap. Nuclus make model- P282 (Digiflow controller) is flow rate indicator cum totaliser with one / two relay output. As per Relay operation Nuclus model P282 operate in four different mode 1) TOTALIZER mode- This mode unit shows flow rate & totaliser in selected eng.. Unit 2) BATCH CONTROLLER mode- This mode unit shows flow rate & Totalizer with one / two relay output on Totalizer for Batching application to ON/OFF Pump / solenoid valve. 3) PULSE CONTROLLER mode- This mode unit shows flow rate & Totalizer with one / two relay output on Totalizer for dosing application to controller metering pump / solenoid valve. 4) RATE SWITCH mode- This mode unit shows flow rate & Totalizer with one / two relay output on flow rate for HIGH / LOW alarm to operate lamps, sirens, etc. Technical Specifications for P282 Function: Rate indicator with Totaliser Display: Supply Voltage: Linearity: Accuracy: Input: backlit alphanumeric 2 x 16 LCD 230 V AC + 1% of FSD_ + 0.05 %._ from Nuclus sensor P812 Scale Factor: 00.1000000 Configuration Lock: Password Protection. Calibration: Using front membrane keys Output: 5A pot. Free contact @ 230 VAC. Housing: Plastic ABS. Protection: IP 65 for field mounting Meter Size: 110mm X 110 mm X 140mm Cutout Size: 90 mm X 90 mm Operating Temp.: Operating: 0 to 50 C. Sensor Supply: 12 VDC(±10%), 30 ma.

Programing ( TOTALIZER Mode ) SET SCL ENT Nuclus Digiflow Controller in TOTALIZER mode is rate indicator cum totalizer Calibration Procedure PASSWORD Press key for 3 seconds display shows 0000 PASSWORD Press & keys to set password as 1603 SCALE FACTOR Than press key display shows scale factor 00.0000000 For re-calibration of flow meter the previously programmed scale factor can be increased in proportion to the difference in the reading between the actual flow rate and the displayed reading. Press & keys to set scale factor than press Key, display shows Discharge unit selection SET UNIT LPH Press Than press key to select operating unit as M3/hr / LPH / LPM / LPS / GPM us / GPM uk. Key, display shows averaging time for rate in sec. AVERAGE TIME 00 Sec Press & keys to set flow rate averaging time in seconds 1 to 20 seconds max Than press Key, display shows CONFIG COMPLETE Than press Key, display shows < 0-0 - 0 > SAVING PARAMETER < 0-0 - 0 > Than display shows regular flow rate & Totalizer reading 5

Total Reset Procedure Press key for 3 seconds display shows Press & keys to set password as PASSWORD 0000 PASSWORD 1600 Than press key display shows scale factor RESET TOTALIZER NO Press key to select reset totalizer YES / NO than press key display shows CONFIG COMPLETE Than press Key, display shows < 0-0 - 0 > Than display shows regular flow rate & Totalizer reading Types of installation fittings SAVING PARAMETER < 0-0 - 0 > S. S. T fitting threaded end Use for 15 NB to 40 NB line size Threading as per BSP standard S. S. T fitting Stub end For 50 NB to 100 NB line size MS flanges as per Bs10 table D SS T fitting Welded flange end Block Fitting Use for 15NB & 25NB line size Remove sensor at the time of welding Weld adapter Use for 50 NB to 300 NB line size Cut 36 mm hole weld directly on line Remove sensor at the time of welding For 50 NB to 100 NB line size Flanges as per requirement Weld adapter installation Remove sensor from weld adapter before start welding. The weld adaptor supplied can be directly welded on to any MS / SS pipe line as per following instruction steps Step 1 Cut a hole of 36 mm exactly center of the pipe Step 2 Insert Insert the weld addapter inside the hole Top view Side view 6

Step 3 Align the weld adaptor in such way that the groove in the top of adapter is parallel to the pipe line. Step 4 Weld the adaptor from outside. Top view Side view Insure that at the time of welding there is no welding bur on the threading of the weld adaptor. Insert the flow sensor as per the sensor mounting guidelines. Connection Details for Model P282 Sensor wiring details Sensor 1 V+ Out Com Res Com 4 5 6 1 2 3 7 8 16 17 18 19 20 13 14 15 Relay 1 Reset 9 10 11 Relay 2 12 22 23 24 L N E 230 VAC 21 1 Red colour ( +12 Vdc supply ) 2 Black colour ( pulse output ) 3 White colour / Shield ( - supply ) Before sensor connection to instrument Please refer the manual for specific wiring details. Use Do two core shielded cable for cable extensions. not keep power cable and sensor cable in one conduit pipe. Relay Connections Relay ( OFF ) De-energized Relay ( ON ) Energized External AC / DC Power Device Device connect as per operating mode: Batch Controller- Pump / solenoid valve Relay 1 Relay 2 Pulse Controller- metering pump / solenoid valve Rate Switch- warning lamps / bells / sirens Note: Maximum relay contact ratings 5 A @ 230 VAC External heavy-duty relay must be used for devices with operating currents that exceed the above specifications. 7

Trouble shooting Problem Possible Causes Suggested Solutions Display remains zero even when actual flow is there Flow less than the minimum flow rate. Check if any downstream valve is closed. Open valve. Remove sensor from the fitting & check change in reading by physically rotating the paddle. If meter shows reading check the actual flow rate. Change the fitting if the normal flow is lower than the minimum Sensor not inserted in the correct plane. Ensure that the arrow on the sensor is in direction of flow. Reading getting displayed but not correct. Meter is malfunctioning / not given any output. Rotor not moving freely Remove the sensor, clean Rotor & Pin and ensure free movement of the Rotor. Wrong sensor wiring. Connect the sensor wires as per wiring ( mainly applicable for panel mounted connection details in the manual / on the meters or field mounted units where meter. sensor wire is extended.) Meter & sensor serial number are not matching. Adequate straight run is not provided on inlet & outlet side of sensor. Presence of a pressure reducing valve before the sensor can result in error. Set scale factor disturbed. Flow meter setting disturbed. Ensure that the meters are connected to its corresponding sensor & fitting only. Provide straight run as per guide lines. OR adjust the scale factor to match the actual flow. Provide a bend between the valve & the sensor. Refer installation guide line for proper placement of sensor. Check scale factor. Correct factor as per mentioned on meter or sensor. Correct meter setting as per operating manual. No display / shows only back light Totalizer is reset to zero when power supply is OFF No power supply Micro-Controller hanged CR 2032 Battery is drain. Checks input supply and make proper connections. Switch off supply for 1 minute and then switch On the supply again Replace new CR 2032 Lithium Battery.