ELB ES. Product Installation Instructions

Similar documents
ELB ELB

Raychem CSJA Safety Instructions. Safety Instructions. Customer Service. Kit Contents. Installation Instructions

COOPER POWER SERIES. 600 A 15 kv and 25 kv class BT-TAP connector system installation instructions. Deadbreak Apparatus Connectors MN650004EN

Cold Shrink Silicone Rubber Termination QT-III 7672-S-8-JCN

COOPER POWER SERIES. 600 A 15/25 kv class T-OP II connector assembly installation instructions. Deadbreak Apparatus Connectors MN650048EN

COOPER POWER SERIES. 600 A 15/25 kv class BOL-T and separable splice connector assembly installation instructions

COOPER POWER SERIES. Fused loadbreak elbow connector installation instructions. Loadbreak Apparatus Connectors MN650014EN

COOPER POWER SERIES. 600 A 35 kv class BT-TAP connector system installation instructions. Deadbreak Apparatus Connectors MN650003EN

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8(S)-JCN

Installation Instructions

3M Cold Shrink Splice Kit QS-III 5536A

3M Cold Shrink QT-III Silicone Rubber Termination

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit

3M Cold Shrink QT-II Silicone Rubber Indoor Termination Kits

Cold Shrink Silicone Rubber Termination QT-III (With High-K Stress Relief)

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination

3M Cold Shrink QT-III Silicone Rubber Indoor Tubular Termination Kit

3M Cold Shrink QT-III Silicone Rubber Indoor Termination Kits With High-K Stress Relief

3M Cold Shrink QT-lll Silicone Rubber Skirted Termination Kit 7692-S-4, 7693-S-4, 7694-S-4, 7695-S-4, 7696-S-4

Motor Lead Pigtail or V-Stub Splice 5380 Series For 5/8 kv Non-Shielded and Shielded Feeder Cables (Tape, Wire or UniShield Cables)

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-TOW/WOT

COOPER POWER SERIES. Screened Separable Connectors MN650023EN. Effective October 2016 Supersedes March 2012 (IS )

COOPER POWER SERIES. Screened Separable Connectors MN650024EN. Effective October 2016 Supersedes March 2012 (IS )

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kits

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-Tape/LC

3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit With High-K Stress Relief

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TOW/WOT (RW)

3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit

3M Cold Shrink QT-lll Silicone Rubber Indoor Tubular Termination Kits With High-K Stress Relief

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TS (RW)

COOPER POWER SERIES. 200 A loadbreak junction 15 and 25 kv class installation instructions. Loadbreak Connectors MN650015EN

COOPER POWER SERIES. 600 A 15, 25, and 35 kv Class Cleer Loadbreak Bushing Insert Installation Instructions. Loadbreak/Deadbreak Connectors MN650016EN

Installation Instructions K656CY, K656CH and K656I Deadbreak Receptacles

COOPER POWER SERIES. 200 A Fused Loadbreak Elbow Connector Replacement Fuse Installation Instructions. Fusing Equipment MN132021EN

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit

Effective November 2016 Supersedes February 2012 (S )

Loadbreak Elbows. 3 Loadbreak Elbows. 200 Amp 5-15 kv Industrial pg Loadbreak Elbows. 200 Amp 25 kv Industrial pg. 254.

IS94012-ENG - AFN February Revision 6 - Supersedes edition of 28 January and / or. 3 x Stress control mastic, type MFC (Hi-K)

Cold Shrink - Silicone Rubber QTII(X)4S-32H Series Cable Termination Instructions

Installation Instructions

Instructions. Quick Term II 2047MT 74. Quick Term II. Silicone Rubber Termination

Cold Shrink QS T Trifurcating Transition Splice Kit

HVS S 15kV Class

Instructions. Quick Term II 2047MT 56. 3M Quick Term II. Silicone Rubber Termination (with High-K Stress Relief)

(K),(M),(P)489TB/G Up to 42 kv

Product Installation Instructions. Raychem Corporation Electrical Products 8000 Purfoy Road Fuquay-Varina, NC 27526

Loadbreak Apparatus Connectors. 200 A 15 kv Class Loadbreak Elbow Connector with Optional Integral Jacket Seal GENERAL

QT-III Cold Shrink Silicone Rubber

(K),(M)430TB/G Up to 36 kv

Loadbreak Apparatus Connectors

COOPER POWER SERIES. S.T.A.R. type LVR faulted circuit indicator installation instructions. Fault Indicators MN320005EN

Quick Term II. Cold Shrink Silicone Rubber Termination. Quick Term II. Instruction Sheet

200 A 15 kv class loadbreak elbow connector with optional integral jacket seal-canadian Edition

200 A 25 kv and 28 kv class loadbreak elbow connector with optional integral jacket seal-canadian Edition

Cold Shrink QS2013-3T-WS Trifurcating Transition Splice Kit

Installation Instruction EPP /92

200 A 15 kv class loadbreak elbow connector with optional integral jacket seal

200 A 25 and 28 kv class POSI-BREAK loadbreak elbow connector with optional integral jacket seal-canadian Edition

Installation Instructions LINK---C

High-voltage primary bushings installation instructions

COOPER POWER SERIES. K-Limiter back-up current-limiting fuse installation instructions. Fusing Equipment MN132010EN

COOPER POWER SERIES. High-voltage primary bushings installation instructions. OEM Equipment MN800008EN

Tests are conducted in accordance with IEEE Standard 386. ac 60 Hz 1 Minute Withstand 50

Deadbreak Apparatus. connectors. 600 A 15/25 kv Class GENERAL

3M Cold Shrink 1/C Transition Splice Kit QS-III, 5510A-1T-PILC Series

Effective March 2015 Supersedes S August 2012

600 A 35 kv class BT-TAP deadbreak connector

COOPER POWER SERIES. UltraSIL polymer-insulated D-73P disconnect switches installation instructions. Switches MN008004EN

COOPER POWER. SERIES ELF Current-Limiting Dropout Fuse Installation Instructions. Fusing Equipment MN132028EN. Pull ring. Housing

600 A 25 kv class BT-TAP deadbreak connector

Effective May 2017 Supersedes December 2004 (S )

25 kv class fused loadbreak elbow connector

600 A 15 kv class T-OP II deadbreak connector

COOPER POWER SERIES. S.T.A.R. Hot line voltage indicator installation instructions. Fault Indicators MN320011EN. Indicator boot.

S Fault Indicators. S.T.A.R. Type TPR Faulted Circuit Indicator Installation Instructions. Contents INSTALLATION PROCEDURES

Product Description: Objective and Certification: Test Samples and Test Cable:

Underground Bus Bar Distribution System 03 SEP 13 Rev B

COOPER POWER SERIES. Edison Modular Fuse (EMF) Installation Instructions. Fusing Equipment MN132031EN

COOPER POWER SERIES. ELSG Full-Range Current-Limiting Fuse Re-Fusing Instructions. Fusing Equipment MN132017EN

INSTALLATION PRODUCTION TESTS

Type NR oil switch installation and operation instructions

copper stud. If a 900 A rating is desired, specify a C as the 8th digit when determining your part number (See Table 3, page 3.)

COOPER POWER SERIES. HX-CB loadbreak fuse cutout installation instructions. Fusing Equipment MN132011EN

COOPER POWER. SERIES CMU Medium voltage power fuse installation instructions. Fusing Equipment MN132032EN

3M Cold Shrink 3-Conductor Inline Splice Kits QS-III 5786A- MT, 5787A-MT and 5788A-MT 25/28 kv for use with Armored and Non- Armored 3/C Cable

3 Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8 Series

C Power Connection Kit

Installation Instruction EPP /02. Terminations for Screened Single Core Polymeric Insulated Cables up to 24 kv without Armour

QS-III. 5513A, 5514A, 5515A and 5516A 15 kv Cold Shrink Inline Splice Kits. Data Sheet CAUTION. 1. Product Description. 2. Applications.

JUL 17 Rev M

600 A 35 kv class separable splices

S Voltage Regulators GENERAL. Contents. Acceptance and Initial Inspection. Handling and Storage. Standards

High Voltage Joints and Terminations up to 72,5 kv 145 kv

MEDIUM VOLTAGE

3M Cold Shrink QS-III Inline Splice Kits 15 kv 5513A, 5514A, 5515A and 5516A

Application Specification Circular Plastic Connector (CPC) Series 45 System 05 AUG 14 Rev D

3M Cold Shrink QT-III Silicone Rubber Termination Kits 7640-T and 7650-T Series 5, 8, 15, 25/28 and 35 kv

Effective June 2016 New Issue

Transcription:

ELB-25-210-ES 200A 25kV Class Loadbreak Elbow with Integral Jacket Seal for Copper Tape (CT) and Jacketed Concentric Neutral (JCN) cables Product Installation Instructions Safety Instructions When installing electrical power system accessories, failure to follow applicable personal safety requirements and written installation instructions could result in fire or explosion and serious or fatal injuries. As TE has no control over field conditions which influence product installation, it is understood that the user must take this into account and apply his own experience and expertise when installing product. Working around energized high-voltage systems may cause serious injury or death. Installation should be performed by personnel familiar with good safety practice in handling high-voltage electrical equipment. De-energize and ground all electrical systems before installing product. Power distribution and transmission products must be properly selected for the intended application. It must be installed and serviced by competent personnel who have been trained and understand proper safety procedures. These instructions are written for such personnel and are not a substitute for adequate training and experience in safety procedures. Suggested Installation Equipment (not supplied with kit) Cable preparation tools General Information TE s ELB-25-210 elbows are designed to terminate underground cables to high-voltage apparatus such as transformers and switchgear that are equipped with load break bushings. They are fully shielded and fully submersible and are designed in accordance to IEEE Standard 386 (latest revision). Loadbreak elbows are designed for use with standard hot stick tools, which allow a load make/break operation with a physical disconnect. Customer Service For 24 hour customer service, call 800-327-6996. Read and understand the contents of these instructions before installation and follow all locally approved procedures and safety practices before installing or operating this equipment These instructions cannot cover all details or variations in the equipment, procedures, or processes described, nor provide directions for meeting every possible contingency during installation, operation, or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for the user s purpose, please contact your TE sales representative. These instructions are not intended to supersede or replace existing safety and operating procedures. Upon receipt of a product, inspect it thoroughly for damage and loss of parts incurred during shipment. If damage or loss is discovered, file a claim with the carrier immediately or contact your TE representative. 1

Installation Instructions 1. Check kit Check kit to insure proper fit with the cable. Sizes shown in table 1. Table 1: 200amp 25kV Loadbreak Elbow Size Reference Chart (Integal Seal) Cable Size(AWG/Kcmil) Insulation Diameter STR/COMPR COMPT/SOL in(mm) 25 kv - 260 mil (100%) Insulation #1 1/0 0.720-0.985 (18.3-25.0mm) ELB-25-210B1-ES 1/0 2/0 0.720-0.985 (18.3-25.0mm) ELB-25-210B10-ES 2/0 3/0 0.920-1.185 (23.4-30.1mm) ELB-25-210C20-ES 3/0 4/0 0.920-1.185 (23.4-30.1mm) ELB-25-210C30-ES 4/0 250 1.040-1.304 (26.4-33.1mm) ELB-25-210D40-ES Choose the cable type (Choice 1 below or Choice 2: Copper Tape Shield on page 7) and follow the directions given. Choice 1: Jacket Concentric Neutral or Unjacketed Concentric Neutral cable 2. Position cable For illustrative purposes, JCN is being shown to the right. 16 (406mm) 8 (203mm) C L8 (203mm) Cable Bushing Transformer Fig. 102 3. Clean and degrease Clean and degrease the end of the cable jacket for 24 with solvent. 2

4. Cut back cable jacket Position the cable with 8 (203mm) overlap to the bushing center. Mark the cable jacket 8 (203mm) below the bushing center Position the cable with enough slack to allow movement of elbow to insulated parking bushing. Remove 16 (406mm) of cable jacket to expose neutral wires. 16 (406mm) 8 (203mm) C L8 (203mm) Cable Bushing Transformer If using an elbow sealing kit - review the instructions before starting the elbow cable prep to avoid redundant steps. For illustrative purposes, JCN is being shown to the right. Fig. 102a 5. Prepare cable Apply 2 layers of gray mastic on the cleaned, cable jacket cutback for a minimum of 1 (25mm). 1.0 (25mm) 8.0 (203mm) Carefully bend neutral wires back onto the cable jacket. Temporarily secure wires with PVC tape. Measure 8 (203mm) up from the cable jacket cut back and cut off excess cable. Make a clean square cut. Mastic Concentric neutral wires Extruded semi-con insulation shield Cut Fig. 103 6. Remove semi-con Remove semi-con as shown. It is very important to make a square cut of the semi-con, without nicking the insulation. 5-7/8 (150mm) Semi-con Insulation Fig. 108c 7. Remove insulation Remove insulation exposing conductor 2-1/8 (54mm). 2-1/8 (54mm) Bare conductor Fig. 104 3

8. Chamfer and clean insulation Remove sharp edge of insulation by chamfering the end of the cable insulation at a 15 0 angle, approximately 1/8 back. 15 0 Chamfer 1/8 Cable insulation Fig. 105 9. Install connector Prepare aluminum conductor by wire brushing just prior to insertion into connector. Remove protective cap and fully insert conductor into compression lug. Before crimping the lug, confirm that the dimension between semi-con cutback to the end of lug is approximately 6-7/8 (174mm). Crimp the lug following the instructions supplied. Wipe excess inhibitor from connector. After installation, use abrasive strip to deburr lug if necessary. Conductor Insulation 6-7/8 (174mm) Straight Cut Fig. 108 CATALOG NO. PART NO. BCM2E-6 1710979-1 BCM2E-5 1710979-2 BCM2E-4 1710979-3 BCM2E-3 1710979-4 BCM2E-2 1710979-5 BCM2E-1 1710979-6 BCM2E1/0 1710979-7 BCM2E-2/0 1710979-8 BCM2E-3/0 1710979-9 BCM2E-4/0 1-1710979-0 CONDUCTOR SIZE (ALUMINUM OR COPPER) STD STR/ COMPR NOTE: Not to Scale 2-1/8 [54mm] Strip Length DIE CROSS REFERENCE BURNDY KEARNEY T&B CSA COMPACT SOLID MD6, 7 Y35, Y39 Y45 O H1, H2 6 5 5 5 4 4 4 3 3 3 2 2 2 1 1 1 1/0 1/0 1/0 2/0 2/0 W243 (3) WBG (3) BG (5) U243 (2) UBG (3) U27RT (3) U243 (2) UBG (3) U27RT (3) TBM15 TBM14M Tool Y45 requires the use of adapter PT6515 when U-type dies are to be used. Overlap crimps. BURNDY, KEARNEY, and T&B are trademarks of their respective owners. 5/8 (5) Nose 9/16 (3) or 572 (2) 2/0 3/0 3/0 --- 3/0 4/0 4/0 4/0 250 --- W247 (4) U29RT (3) U27ART (3) U29RT (3) U27ART (3) 50 (3) DIE NO. 22(2) 747 (3) 747 (2) 62 (2) --- 4

10. Apply mastic Apply two layers of gray mastic over the folded back neutral wires and previously applied mastic near the jacket cutback. Also apply two layers of mastic 1/2 onto cable semicon, forming a jacket seal. Wrap the cable and mastic with one half lapped layer of PVC tape(not included). PVC tape over gray mastic 1/2 (13mm) onto semi-con Fig. 104a 11. Install elbow Thoroughly clean the insulation with a solvent dampened cloth, wiping from the connector toward the semi-con. Lubricate the exposed insulation with the provided silicone grease, always working toward the cable semi-con. Push the elbow body onto the lubricated cable with a slight twisting motion until the connector eye is aligned with the elbow bushing interface. Clean and Lubricate Optional test point facing installer Elbow Fig. 110 Align 12. Install loadbreak probe Make sure the gap between the cable jacket cutback and the end of the elbow does not exceed 2 (50mm). By hand, carefully insert the threaded end of the loadbreak probe into the interface opening and thread the probe into the copper top connector until hand tight. Use the provided torque tool to properly tighten the probe by inserting it into the hole in the probe, turning clockwise. Proper torque is reached when the tool bends 180 degrees. If a different installation tool is used, it must apply a torque of 8.1-10 lbf-ft (11.0-13.5 N-m). Loadbreak probe Torque tool Fig. 110a 5

13. Install jacket seal Grasping the tabs of the Integral jacket seal, pull downward so jacket seal unfolds over the PVC tape covered mastic. Fig. 110aa 14. Ground system Connect the grounding eye of the elbow with a minimum #14 AWG copper drain wire. Connect drain wire to cable s concentric neutrals. Connect neutral wires to system ground. Installation is complete. #14 AWG drain wire Fig. 110b 6

Choice 2: Copper Tape Shield 13. Prepare cable Remove outer jacket 9.0 (228mm) from end of cable. Remove copper tape shield to 1 (25mm) from jacket cutback. 9.0 (228mm) 1.0 (25mm) Copper tape shield Fig. 103cts 14. Remove semi-con 5-7/8 (150mm) Remove semi-con as shown. Semi-con Insulation Fig. 104cts 15. Remove insulation Remove insulation exposing conductor 2-1/8 (54mm). 2-1/8 (54mm) Bare conductor Fig. 104x 16. Chamfer and clean insulation Remove sharp edge of insulation by chamfering the end of the cable insulation at a 15 0 angle, approximately 1/8 back. 1/8 15 0 Chamfer Clean Cable insulation Fig. 105x 17. Install connector See crimping chart on page 4. Prepare aluminum conductor by wire brushing just prior to insertion into connector. Remove protective cap and fully insert conductor into compression lug. Before crimping the lug, confirm that the dimension between semi-con cutback to the end of lug is approximately 6-7/8 (174mm).Crimp the lug following the instructions supplied. Wipe excess inhibitor from connector. 6-7/8 (174mm) Fig. 108x After installation, use abrasive strip to deburr lug if necessary. 7

18. Install ground braid (1) Lay the ground braid on the cable with the solder block aligned with the jacket cutback and the short end of the braid over the exposed copper tape shield. Ground braid Moisture block Spring clamp (2) Attach the braid to the tape shield by placing two wraps of the spring clamp over the braid. (3) Fold the short end of the braid back over the spring clamp wraps as shown. Continue to wrap the remaining clamp over the braid. Tighten clamp by twisting it in the direction it is wrapped and secure with the copper foil tape provided. 1 2 3 Fig. 110cts 19. Install mastic and PVC tape Clean cable jacket to 6 from jacket cutback. Install 2 wraps of gray mastic onto jacket at the copper braid solder block. Press the solder block into the mastic. Install remaining mastic over the braid and spring clamp sealing the jacket cutback. Wrap the mastic with 2 layers of PVC tape (not included). PVC tape over gray mastic Fig. 104ab 20. Install elbow Thoroughly clean the insulation with a solvent dampened cloth, wiping from the connector toward the semi-con. Ensure that all traces of conductive residue are removed. Lubricate the exposed insulation with the provided silicone grease, always working toward the cable semi-con. Push the elbow body onto the lubricated cable with a slight twisting motion until the connector eye is aligned with the elbow bushing interface. Optional test point facing installer Clean and Lubricate Elbow Fig. 110cts Align 8

21. Install Loadbreak Probe Make sure the gap between the cable jacket cutback and the end of the elbow does not exceed 2 (50mm). By hand, carefully insert the threaded end of the loadbreak probe into the interface opening and thread the probe into the copper top connector until hand tight. Use the provided torque tool to properly tighten the probe by inserting it into the hole in the probe, turning clockwise. Proper torque is reached when the tool bends 180 degrees. Install Loadbreak Probe If a different installation tool is used, it must apply a torque of 8.1-10 lbf-ft (11.0-13.5 N-m). Loadbreak probe Torque tool Fig. 110acts 22. Install jacket seal Grasping the tabs of the Integral jacket seal, pull downward so jacket seal unfolds over the PVC tape covered mastic. Fig. 110aaa 23. Ground system Connect the grounding eye of the elbow with a minimum #14 AWG copper drain wire. Connect drain wire to grounding braid and connect the ground braid to system ground. Installation is complete. #14 AWG drain wire Fig. 110bcts The Information contained in these installation instructions is for use only by installers trained to make electrical power installations and is intended to describe the correct method of installation for this product. However, TE has no control over the field conditions which influence product installation. It is the user s responsibility to determine the suitability of the installation method in the user s field conditions. TE s only obligations are those in TE s standard Conditions of Sale for this product and in no case will TE be liable for any other incidental, indirect or consequential damages arising from the use or misuse of the products. Raychem, TE Connectivity and TE connectivity (logo) are trademarks. Other trademarks used are the property of their respective owners. Copyright 2013 Tyco Electronics Corporation, a TE Connectivity Ltd. Company. All Rights Reserved. 9