Combined instrument transformers

Similar documents
Inductive voltage transformers

Inductive voltage transformers

Inductive voltage transformers

Inductive voltage transformers

Combined instrument transformers

Current transformers. Outdoor operation SF 6 -gas insulated. JGF ( ) kv

Inductive voltage transformers

Inductive voltage transformers

Inductive voltage transformers

Cable current transformers

High-current Transformers

DM Condenser bushings, kV DURESCA

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

Transformer bushings, type GOH. Technical guide

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st New RIS transformer bushings The paper-free solution

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide

OTCF. Grid Solutions. Capacitor Voltage Transformers 72.5 kv to 800 kv. Quality Product Design. Seismic Withstand Capability.

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

Power Voltage Transformers for Air Insulated Substations

DURESCA Busbar system. For indoor and outdoor applications, type DE / type DG DURESCA

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

1ZSE en, Rev. 9. Transformer bushings, type GOB Technical guide

Medium Voltage. KOFD Indoor Type Current Transformers Cast Resin Insulated. Catalogue. 12, 13.8, 17.5, 24 and 36 kv KOFD 1 GB

GAS INSULATED VOLTAGE TRANSFORMERS.

Volt Instrument Transformers

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

EMPAC Metal enclosed capacitor bank for wind applications

Combined Current and Voltage Instrument Transformer CVS-P-24-O Technical Specifications

Bushings for High Voltage AC Applications

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide

Current transformers. Current transformers

Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

BUSHINGS: GENERAL INFORMATION

Distribution transformers Efficiency over life-cycle

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers

Transformer bushings, type GOA 250. Installation and maintenance guide

Transformer Bushings Type COT COT kv to 245 kv up to 3150 A IEC 137

Product brochure. Gas-insulated switchgear ELK-4, 800 kv Pioneering technology for extra-high voltage applications

Gas-Insulated Switchgear. Type 8VN1 blue GIS up to 145 kv, 40 ka, 3150 A

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com

Type HS PEXLIM-P Surge Arresters Maximum System Voltage 123 kv to 800 kv

3EQ Composite Housed Surge Arresters

power cable accessories

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

3EQ Composite Housed Surge Arresters Saving Money and Space, Gaining Reliability

B kv Gas-insulated Substations

Compact Integrated Distribution Substation (CIDS)

NXPLUS C Single busbar. Maintenance-free for lifetime

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

kv А

Step 1: Collection of required data

Transformer bushings, type GSA-OA Technical guide

Kuhlman Electric Corporation Volt Instrument Transformers

CP Automatic capacitor bank

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)

SICOP. Bimetal Overload Relays Type 3UA5/6 & 3UC5/6. Introduction. Application

MEDIUM VOLTAGE SWITCHGEAR

3 TM Cold Applied Barrier Boot System

67 IB INTERLOCKED SOCKET-OUTLET IEC 309 STANDARDS

Current accuracy class. Sensor principles

PNO Condenser Bushings from 52 kv to 420 kv Oil-to-air - Oil-Impregnated Paper

HIGH VOLTAGE SURGE ARRESTER SPECIFICATION

PHOENIX CONTACT

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

Single-phase CT current transformers Cat. Nos :

KOLMA and IHDA Indoor Type Cable Current Transformers. Catalogue. Catalogue KOLMA 1 GB Medium Voltage. ABB Transmit KKOLMA 1 GB

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2

Completing the picture

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)

Surge arrester POLIM-H..SD

MICAFIL RIP Transformer Bushings AirRIP / RTKF kv

with Vacuum Circuit Breaker HAF

OTAA Oil Impregnated Paper (OIP) Bushing for IEEE/ANSI Market

1ZSE en, Rev. 9. Transformer bushings, type GSA-OA Technical guide

Metal Clad Air Insulated Switchgear

Kuhlman Electric Corporation Volt Instrument Transformers

PABS. AIR-TO-SF 6 - Gas-insulated bushing IEC STANDARDS ANSI STANDARDS AN ALSTOM COMPANY

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin

Technical Data Accessories MCBs Ex9B.

2. INDUCTIVE VOLTAGE TRANSFORMERS Dry and oil-paper insulation

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

BOWTHORPE EMP MEH SURGE ARRESTERS (IEC) ENERGY /// MEH SURGE ARRESTERS IEC

Product Brochure. Gas-insulated Switchgear ELK-14 The modular system for GIS, 245 kv

Metal Clad Switchgears

3EP1 Surge Arrester. Metal-oxide surge arrester without series gaps for high-voltage systems up to U m. = 170 kv

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

132/11 kv, 25 MVA MOBILE SUBSTATION

Transcription:

Combined instrument transformers Outdoor operation Oil-paper insulated EJOF (24 170) kv

General description Combined instrument transformers type EJOF are used in high voltage networks within the 24 170 kv range. They transform high voltage and high current into standardised values for meters, measuring and protection devices. The inner construction of a combined instrument transformer is similar to the construction of the current and voltage transformer. The current transformer is located in the head and the voltage transformer in the bottom housing of the combined instrument transformer. The fine graded bushings are inside the insulator. The high voltage insulation is based on oil-paper technology. High-grade, PCB-free mineral oil is used. The expansion bellows made from stainless steel is located above the head housing of the combined instrument transformer. This unit acts as volume compensation for the oil in case of temperature variations. The oil level is indicated by a mechanical system in the window of the bellows cover. All metal housings and flanges are made from a special aluminium alloy. These parts can be colour coated on request. All combined instrument transformers have either a high-quality porcelain or a high-grade silicone composite insulator. Different creepage distances are available according to the different pollution classes, as specified in the standards. The hermetic sealed housing protects the oil-paper insulation against atmospheric influences. The generously sized terminal box has a cover which can be opened sidewards. This allows easy connection of the secondary cables. The terminal box has a flange without holes by default. Cable glands, circuit diagram and individual safety instructions can be preinstalled on request. Advantages of combined instrument transformers Reduced transport costs with one unit instead of two Less space needed with just one footprint Lower material costs due to a reduced number of supports and fewer primary connections Lower installation effort as only one unit has to be installed instead of two

Highlights Easy primary changeover Excellent protection against moisture Installation-friendly terminal box A clear and easy primary changeover with a ratio of 1:2 or 1:2:4 is available. The primary changeover is adjusted with one metal plate at one side of the head only. No need to dismount or move the primary connections during adjustment. The inner side of the instrument transformer is protected against moisture by means of special sealing rings. All housings are designed with a drain-age area to protect the sealing surfaces of the housings against rain. This significantly reduces crevice corrosion. The housing elements are connected with special stainless steel screws. They are designed in such a way that no humidity can enter the screw hole. The generously sized terminal box with a cover that can be opened sidewards, is secured with captive screws. It can accommodate terminal blocks, fuses, surge arrestors, additional auxiliary contacts, spark gaps and sealable covers. By default, all terminal boxes have a flange without holes. Cable glands can be preinstalled on request. An additional terminal box can be supplied on request.

Design Bellows cover with oil level indicator Expansion bellows Lifting lugs Housing with drainage area Primary connection CT part with iron cores, secondary windings and high voltage insulation Primary changeover Porcelain or silicone composite insulator Bushings Possible options Colour coated housings and flanges Fuses or miniature circuit breakers (MCBs) with or without auxiliary contacts in the terminal box VT part with secondary windings VT part with primary winding and high voltage insulation Surge arrestors and spark gaps in the terminal box Pressure monitoring with auxiliary contacts Heater in the terminal box Terminal box with rating plate Iron core of VT Sealable cover on terminals for billing purposes Additional terminal box Main earth connection Tan δ terminal for capacitance and di-electric dissipation factor measurement Sealable oil drain valve Oil drain valve

Technical data 123 170 kv 24 72 kv X X 1 x I N A B 2 x I N 4 x I N E F D C Type EJOF 24 36 72 123 145 170 Standard IEC / IEEE Highest voltage for equipment kv 24 36 72.5 123 145 170 Rated power-frequency withstand voltage kv 50 70 140 230 275 325 Rated lightning impulse withstand voltage kv 125 170 325 550 650 750 Frequency Hz 16.7 / 50 / 60 Primary rated current A 5000 Secondary rated current A 1 / 5 Rated short-time thermal current [Ith] ka/1s 63 Rated dynamic current [Idyn] ka 160 Accuracy class CT part 0.1 3; 0.2S; 0.5S; P; PR; PX; PXR; TPX; TPY; TPZ Accuracy class VT part 0.1 3; 3P; 6P Rated thermal limiting output VT part VA 1500 3000 Max. simultaneous burden (cl. 0.2) VA 200 300 Max. number of CT cores 7 Max. number of VT windings 5 Type EJOF 24 36 72 123 145 170 Height of unit* A mm 1591 1591 1791 2484 2659 2959 Height to primary terminal* B mm 1145 1145 1345 2038 2203 2503 Depth of unit including terminal box C mm 526 526 526 710 710 730 Depth of unit base D mm 360 360 360 500 500 500 Width of unit base E mm 360 360 360 520 520 520 Distance between screw holes at base F mm 310 310 310 450 450 450 Min. creepage distance* mm 1040 1040 1900 3080 3770 4394 Approximate weight* kg 295 295 470 500 515 550 * with standard composite silicone insulator, creepage distance 25 mm/kv

Global presence PFIFFNER Instrument Transformers Ltd 5042 Hirschthal Switzerland Phone +41 (0)62 7392828 Fax +41 (0)62 7392810 E-Mail sales@pmw.ch Internet www.pmw.ch PFIFFNER Transformatör A.S. 06750 Akyurt /Ankara Turkey Phone +90 (0)31 28475521 Fax +90 (0)31 28475421 E-Mail info@pfiffner.com.tr Internet www.pfiffner.com.tr PFIFFNER do Brasil Ltda 88307-740 Itajaí Brazil Phone +55 (0)47 33481700 Fax +55 (0)47 33481700 E-Mail pfiffner@pfiffner.com.br Internet www.pfiffner.com.br PFIFFNER Deutschland GmbH 25524 Itzehoe Germany Phone +49 (0)48 21408270 Fax +49 (0)48 214082729 E-Mail sales@pfiffner-messwandler.de Internet www.pfiffner-messwandler.de MGC Moser-Glaser AG 4303 Kaiseraugst Switzerland Phone +41 (0)61 4676111 Fax +41 (0)61 4676110 E-Mail info@mgc.ch Internet www.mgc.ch ALPHA Elektrotechnik AG 2560 Nidau Switzerland Phone +41 (0)32 3328700 Fax +41 (0)32 3312679 E-Mail mail@alpha-et.ch Internet www.alpha-et.ch This document has been drawn up with the utmost care. We cannot, however, guarantee that it is entirely complete, correct or up-to-date. Copyright PFIFFNER 2015.01 Subject to change without notice. HIGH VOLTAGE Manufacturer of INSTRUMENT transformers since 1927 MEDIUM VOLTAGE LOW VOLTAGE