1 Catalogue KOLMA and IHDA Indoor Type Cable Current Transformers Catalogue KOLMA 1 GB Medium Voltage ABB Transmit 1 KKOLMA 1 GB
2 KOLMA and IHDA Indoor Type Cable Current Transformers Index Description... 3 Technical data and ordering information Cable Current Transformers type KOLMA... 4 How to select the correct residual current transformers... 4 Technical data... 4 Installation... 5 Number of turns and terminal markings... 5 Current rations and rated burdens for accuracy class 10 P Ordering data... 6 Current transformers type IHDA... 7 Selection table... 7 Technical data... 7 Special current transformers KOKM and KOKU Accessories Ordering data Overall dimensions KOLMA, KOLA IHDA ABB Transmit KOLMA 1 GB
3 KOLMA and IHDA Indoor Type Cable Current Transformers Description Transformers, KOLMA_ and KOLA_ are suitable for the measurement of the sum of three-phase currents in a 3-phase cable. Under normal operating conditions this sum is zero. In the event of an earth-fault the sum of the currents is equal to the earthfault current and a corresponding current flows in the secondary. IHDA 05 current transformers are suitable for measuring of phase currents in low voltage switchgear. An uninsulated busbar or low voltage cable serves as the primary conductor. These transformers are used together with static earth-fault relays. The cable current transformers can generally be used when measuring the residual current e.g. to prewarn of, or locate an earth-fault. ABB Transmit 3 KKOLMA 1 GB
4 Cable Current Transformers type KOLMA Technical data and ordering information How to select the correct residual current transformers The transformer for an earth-fault relay is selected according to dimension of the window, and construction of the transformer. For types KOLMA 06 A1, and KOLMA 06 D1, the number of turns used in the secondary winding is selected according to the relay setting value, and the earth-fault current or the required current ratio. In addition correct functioning of the earthfault protection relays for KOLMA 06 A1 and KOLMA 06 D1 is easy to test by means of the test winding (terminals P1x - P2x) of the transformer. The test winding is rated for 6 A max. continuous current. Table 1. Selection of residual current transformers Type Window diam. Construction Weight mm kg KOLMA 06 A1 90 Ring core, multi-tap secondary 7.0 KOLMA 06 A2 58 Ring core 2.9 KOLMA 06 B2 100 Ring core 5.4 KOLMA 06 D1 180 Ring core, multi-cap secondary 11.5 KOLMA 06 D2 180 Ring core 11.4 KOLA 06 B2 100 Split ring core 6.0 KOLA 06 D2 180 Split ring core 11.0 Technical data The primary winding of indoor type cable current transformers is either a cable or a busbar, which is insulated for the application voltage. The secondary winding and ring shaped iron core is cast in resin which has good electrical and mechanical properties Cable current transformers, types KOLMA_ Rated voltage 0.72 kv (1) Insulation test voltage 50 Hz 1 min 3 kv (IEC 185) Frequency 50 Hz (60 Hz) Rated thermal current 1.2 x I pn Short-time withstand current I th 1 s 60 x I pn (2) Peak withstnad current I dyn 2.5 x I th Secondary terminals For 6 mm 2 conductor Operating temperature range o C (1) The insulation level of the primary conductor determines the maximum operating voltage. (2) KOLA 06 B2 is type tested for 10 ka 3 s. 4 ABB Transmit KOLMA 1 GB
5 Cable Current Transformers type KOLMA Technical data and ordering information Installation The KOLMA-types must be installed before the cables and cable terminations are connected. INST With the KOLA 06 B2 and KOLA 06 D2 -types, the ring core can be opened and thus the transformer can be installed eventhough the cable is already connected. The two halves of the ring core are tightened together with four screws which also guide the halves to the correct position. The secondary winding is distributed over both halves of the core. The two sections of the winding are connected together with two connecting pieces. Cable current transformers are fastened either by means of the fixing base or by the nuts cast into the transformer frame. When installing the transformer, the effect of the current in the metal armour or in the protective conductor must be eliminated. In case the metal armour or the protective conductor is drawn through the transformer, the earthing conductor must be drawn back through the transformer for earthing. The earthing conductor between the cable termination box and the transformer, must not be connected to conductive structures, and the metal cable termination box must be insulated from the supporting structures. On a multi-ratio transformer the unconnected secondary winding terminals and test winding must not be short circuited. Number of turns and terminal markings KOLMA 06 A1 KOLMA 06 D1 KOLMA 06 A2 KOLMA 06 B2 KOLMA 06 D2 KOLA 06 B2 KOLA 06 D2 KOLMA ABB Transmit 5 KKOLMA 1 GB
6 Cable current transformers type KOLMA Current rations and rated burdens Technical data and ordering information Table 2. Current ratios and rated burdens for accuracy class 10 P 10 Design data. Types KOLMA 06 A1 and KOLMA 06 D1 Current ratio Secondary terminals Burden / VA Type A KOLMA 06 A1 KOLMA 06 D1 50/1 S4 - S /1 S3 - S /1 S1 - S /1 S1 - S /5 S1 - S /5 S2 - S /5 S1 - S /5 S4 - S /5 S3 - S /5 S1 - S /5 S3 - S /5 S1 - S Table 3. Current ratios and rated burdens for accuracy class 10 P 10 Design data. Types KOLMA 06 A2, KOLMA 06 B2, KOLMA 06 D2 and KOLA 06 B2 Type Current ratio Secondary terminals Burden A VA Openable residual current transformers, type KOLA 06 B2 complete with fixing base KOLMA-ZK 1 and terminal cover KOK-ZAX 14. KOLMA 06 A2 100/1 S1 - S2 2.0 KOLMA 06 B2 100/1 S1 - S2 2.5 KOLMA 06 D2 100/1 S1 - S2 2.0 KOLA 06 B2 100/1 S1 - S2 2.0 KOLA 06 D2 100/1 S1 - S2 2.0 Ordering data quantity type Accessores shall be ordered separately. 6 ABB Transmit KOLMA 1 GB
7 Current transformers type IHDA 05 Technical data and ordering information Current transformer series IHDA 05 for measuring of phase currents IHDA 05 current transformers are suitable for measuring of phase currents in low voltage switchgear. An uninsulated busbar or low voltage cable serves as the primary conductor. Series IHDA 05 current transformers can also be used for measuring the phase current at voltages even higher than 0.72 kv, if the insulation of the high voltage primary conductor fulfils the respective standards for the operating voltage. Selection of current transformers Transformer selection is made according to tables 4 and 5. Ordering On order please mention quantity, type and class. Example: 3 pcs IHDA 05 B1-150/1, class 3 Technical data Rated voltage 0.72 kv (1) Insulation test voltage 50 Hz 1 min 3 kv (IEC 185) Frequency 50 Hz (60 Hz) Rated thermal current 1.2 x I pn Short-time withstand current I th 1 s 60 x I pn (2) Peak withstnad current I dyn 2.5 x I th Secondary terminals For 6 mm 2 conductor Operating temperature range o C (1) The insulation level of the primary conductor determines the maximum operating voltage. ABB Transmit 7 KKOLMA 1 GB
8 Current transformers type IHDA 05 Technical data and ordering information Table 4. Selection of current transformers. Secondary current I sn = 1 A Rated frequency 50 Hz Performance values according to IEC 185 < < F s = F a = Instrument security factor Accuracy limit factor Type Window Prim. Burden (VA) Weight diam. curr. Class and Fs or Fa IHDA mm A 0.5 Fs 1 Fs 3 Fs 10P Fa kg 05A1 100/ A1 150/ A1 200/ A1 300/ A1 400/ A1 500/ A1 600/ B1 100/ B1 150/ B1 200/ B1 300/ B1 400/ B1 500/ B1 600/ B1 800/ C1 400/ C1 500/ C1 600/ C1 800/ C1 1000/ D1 600/ D1 800/ D1 1000/ D1 1200/ D1 1500/ D1 1600/ E1 1500/ E1 1600/ E1 2000/ Cable current transformers with one secondary winding, typ IHDA_ ABB Transmit KOLMA 1 GB
9 Current transformers type IHDA 05 Technical data and ordering information Table 5. Selection of current transformers. Secondary current I sn = 5 A Rated frequency 50 Hz Performance values according to IEC 185 < < F s = F a = Instrument security factor Accuracy limit factor Type Window Prim. Burden (VA) Weight diam. curr. Class and Fs or Fa IHDA mm A 0.5 Fs 1 Fs 3 Fs 10P Fa kg 05A1 100/ A1 150/ A1 200/ A1 300/ A1 400/ A1 500/ A1 600/ B1 100/ B1 150/ B1 200/ B1 300/ B1 400/ B1 500/ B1 600/ B1 800/ B1 1000/ B1 1200/ C1 400/ C1 500/ C1 600/ C1 800/ C1 1000/ C1 1200/ C1-1500/ C1-1600/ D1 600/ D1 800/ D1 1000/ D1 1200/ D1 1500/ D1 1600/ E1 1500/ E1 1600/ E1 2000/ E1 2400/ E1 2500/ E1 3000/ ABB Transmit 9 KKOLMA 1 GB
10 Special current transformers Technical data and ordering information Special current transformers KOKM 06_ and KOKU 06_ Special indoor type current transformer type KOKM 06 J2. Window size 300 x 500. Examples of some special transformer. Left: KOKM 06 for indoor use. Right: KOKU 06 for outdoor use. We also manufacture current transformers cast in epoxy resin, to meet special demands, both for outdoor and indoor use. Enquires for these special transformers should mention the following data: 1. Quantity 2. Current ratio I pn /I sn (A) 3. Burden (VA) 4. Accuracy class 5. Window dimension (mm) 6. Other limiting data such as instrument security factor, dimensions of transformer, fixing of transformer (fixing base) etc. 7. Indoor or outdoor use Maximum service voltage for these transformers is 0.6 kv. The insulation of the primary conductor determines the highest permissible system voltage. 10 ABB Transmit KOLMA 1 GB
11 Accessories Ordering data Ordering data for accessories - quantity - type Table 6. Selection of accessories for KOLMA_ and KOLA_ Description of accessory Type Suitable for use together with transformer Fixing base KOLMA-ZK 1 KOLMA 06 A1 Fixing base KOLMA-ZK 1 KOLMA 06 A2 Fixing base KOLMA-ZK 1 KOLMA 06 B2 Fixing base KOLMA-ZK 1 KOLA 06 B2 Fixing base KOLMA-ZK 2 KOLMA 06 D1 Fixing base KOLMA-ZK 2 KOLMA 06 D2 Fixing base KOLMA-ZK 2 KOLA 06 D2 Secondary terminal cover KOK-ZAX 14 KOLMA 06 A2 Secondary terminal cover KOK-ZAX 14 KOLMA 06 B2 Secondary terminal cover KOK-ZAX 14 KOLA 06 B2 Secondary terminal cover KOK-ZAX 14 KOLA 06 D2 Table 7. Selection of accessories for IHDA_ Type Description Suitable for IHDA current transformer KOK-ZAX 12 Fixing base (1) A1 KOK-ZAX 13 Fixing base (1) B1...E1 KOK-ZAX 14 Secondary terminal cover (2) B1...E1 (1) The fixing base shall be fixed to the bottom inserts of the current transformer by means of screws equipped with spring washers which are included in the package. The fixing base can be mounted either in line with the current transformer of transversely. (2) The secondary terminal cover shall be mounted on the secondary terminals of the current transformer. The cover includes a bushing sleeve. There are two alternative holes for the outgoing wiring. The cover is sealable. ABB Transmit 11 KKOLMA 1 GB
12 KOLMA Overall dimensions KOLMA 06 A1 KOLMA 06 A2, B2 06A2 06A1 Type A B C D KOLMA 06 A B KOLMA 06 D1, D2 06D1 12 ABB Transmit KOLMA 1 GB
13 KOLA Overall dimensions KOLA 06 B2 KOLA 06 D2 06D2 06B2 ABB Transmit 13 KKOLMA 1 GB
14 IHDA Overall dimensions IHDA 05 A1 IHDA 05 B1, C1, D1, E1 IHDA A1 IHDAB1 Type Dims./mm IHDA A B C D 05 B C D E ABB Transmit KOLMA 1 GB
15 IHDA Overall dimensions Base for IHDA 05 A1 Type KOK-ZAX 12 Base for IHDA 05 B1, C1, D1, E1 Type KOK-ZAX 13 05B1 05A1 ABB Transmit 15 KKOLMA 1 GB
16 IHDA Overall dimensions Terminal cover for IHDA 05 B1, C1, D1 and E1. Sealable. KOK-ZAX 14 KOKZAX IHDA.TBL Type IHDA 05 B1 05 C1 05 D1 05 E1 Dim. H mm ABB Transmit KOLMA 1 GB
17 ABB Transmit 17 KKOLMA 1 GB
18 Catalogue KOLMA 1 GB 94-11/97-03 ABB Transmit Oy MV Systems Division Instrument Transformers P.O. Box 613, FIN Vaasa, Finland Phone Fax Ykkös-Offset Oy 3000, ABB Transmit KOLMA 1 GB
Medium Voltage. KOFD Indoor Type Current Transformers Cast Resin Insulated. Catalogue. 12, 13.8, 17.5, 24 and 36 kv KOFD 1 GB
Catalogue Indoor Current Transformers Cast Resin Insulated 1, 13.8, 17.5, 4 and 36 kv 97-1 96-1054 Medium Voltage 1 Indoor Current Transformers Cast Resin Insulated 1, 13.8, 17.5, 4 and 36 kv Index Description...
More informationCable current transformers for indoor applications. Product overview. Cable current transformers. for indoor applications.
Cable current transformers for indoor applications Product overview Cable current transformers for indoor applications Product overview 2 2 Contents 03 Introduction 05 Transformers for residual current
More informationCurrent accuracy class. Sensor principles
Indoor Combi Sensor 12, 17.5 and 25 kv 1250 A and 3200 A KEVCD Highest voltage for equipment kv 12.24 Rated continuous primary current A 1250.3200 Rated transformation ratio for current measurement, K
More informationAir-insulated switchgear UniGear type ZS1
Air-insulated switchgear UniGear type ZS1 ABB Power Technologies / 1-7074 D 12-03-2003 - Air-insulated switchgear UniGear type ZS1 ABB Power Technologies / 2-7075 D 1 2-03-2003 - Rated voltage kv 12 17.5
More informationMEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers
MEDIUM VOLTAGE PRODUCT TJC 4 Indoor voltage transformers 2 TJC 4 INDOOR VOLTAGE TRANSFORMERS Parameters Highest voltage for equipment Power frequency test voltage, 1 min. Lightning impulse test voltage
More informationSingle-phase CT current transformers Cat. Nos :
Index Pages 1. Description - Use... 2 2. Range...2 3. Overall dimensions...2 4. Preparation - Connection... 3 5. General characteristics...5 6. Compliance and approvals...7 1/6 1. DESCRIPTION - USE Closed-type
More informationResin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK
1ZSC563-AAA en, Rev. 2 Resin Impregnated Paper Bushing, Oil to SF 6, Type GSBK Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers,
More information11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls
11kV Compact Switchgear tec - range Minimum to Zero SF6 Insulation Gas. Outec Controls 1 tec xx - 11kV Switchgear Contents 1 tec CB - SF6 Free Switchgear... 3 1.1 Description:... 3 1.2 1.3 Features the
More informationTechnical information
Technical information General Regulations WTL current transformers are special transformers which transfer the primary circuits with prescribed accuracy in smaller secondary circuits. Primary and secondary
More information1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide
1ZSC563-AAA en, Rev. 6 Resin impregnated paper bushing, oil to SF 6, type GSBK Technical guide Original instruction The information provided in this document is intended to be general and does not cover
More informationEMPAC Metal enclosed capacitor bank for wind applications
EMPAC Metal enclosed capacitor bank for wind applications Introduction The EMPAC is a Metal Enclosed Capacitor Bank suitable for voltages between 1 kv and 36 kv for reactive compensation in MV networks
More informationCP Automatic capacitor bank
CP 254 - Automatic capacitor bank STE-CP254_V2_général.doc Page 1 CP 254 - General presentation CP 254 is a range of MV capacitor banks designed to be used in electrical networks up to 36kV. The capacitor
More informationPowerIT Indoor Voltage Transformer Fuses, WBP. Outdoor Voltage Transformer Fuses, BRT. Catalogue 1YMB en. Industrial IT.
PowerIT PowerIT Indoor Voltage Transformer Fuses, WBP Outdoor Voltage Transformer Fuses, BRT Catalogue 1YMB612070-en Industrial IT enabled TM 1. FEATURES Unlimited breaking capacity Short circuit current
More information1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide
1ZSC563-AAA EN, REV. 7 Transformer bushings type GSBK Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More informationResin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide
1ZSC000563-AAC en, Rev. 2 Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers,
More informationIndoor instrument transformers Current transformers Voltage transformers
Medium Voltage Distribution Indoor instrument transformers Current transformers Voltage transformers Catalogue 2008 Selection guide Technical description DE52454 Current transformers (CT) meet standard
More informationAIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR
AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR ANGLER SWITCHING DEVICES CONTENTS 1. General 2. Switchgear Types - Switch Disconnector - Disconnector 3. Cubicle Types - Cubicle with Switch Disconnector
More information1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide
1ZSE 2750-102 en, Rev. 7 Transformer bushings, type GOB Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical
More informationMV Air Insulated Switchgear TAP17. Technical Data TGOOD
MV Air Insulated Switchgear TAP17 Technical Data TGOOD 2017.1 Operating environmental conditions Place of installation: Indoor or outdoor Ambient temperature: 25 ~ +40 (higher or lower temperature optional)
More informationMEDIUM VOLTAGE PRODUCT. KECA 80 D85 Current Sensor Instructions for installation, use and maintenance
MEDIUM VOLTAGE PRODUCT KECA 80 D85 Current Sensor Instructions for installation, use and maintenance 2 KECA 80 D85 CURRENT SENSOR INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE Scope of Contents 2
More informationCombined instrument transformers
Combined instrument transformers Outdoor operation SF 6 -gas insulated EJGF (245 550) kv General description Type EJGF combined transformers are used in high-voltage substations within the 245 550 kv range.
More informationMedium voltage products. KEVCD A combined current and voltage sensor Instructions for installation, use and maintenance
Medium voltage products KEVCD A combined current and voltage sensor Instructions for installation, use and maintenance Instructions for installation, use and maintenance for the KEVCD A combined current
More informationKey features. DESIGNS: - Conservator type - Hermetically sealed
Package Substations OTDS manufactures a large range of oil filled hermitically sealed and conservator type transformers to be used in conjunction with our package substations. We are able to utalise the
More informationBHARAT HEAVY ELECTRICALS LIMITED, JHANSI
BHARAT HEAVY ELECTRICALS LIMITED, JHANSI DESIGN, MANUFACTURING, TESTING, SUPPLY INSTALLATION AND COMMISSIONING OF 11KV VACUUM CIRCUIT BREAKER NOTE : 1 VENDOR must submit complete information against clause
More informationTransformer bushings, type GOH. Technical guide
Transformer bushings, type GOH Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical information required
More informationKECA 80 C85 Current Sensor Instructions for installation, use and maintenance
Medium Voltage Products KECA 80 C85 Current Sensor Instructions for installation, use and maintenance 1. Operating conditions 2 2. Technical details 2 3. Instructions for installation 3 Safety instruction
More informationZero-phase current transformer for F-MPC application. Notification of geometry change in EW Series
To All Customers Rep No. B16002 April 19, 2016 Fuji Electric FA Components & Systems Co., Ltd. Zero-phase current transformer for F-MPC application Notification of geometry change in EW Series Thank you
More informationMEDIUM VOLTAGE PRODUCT. KECA 250 B1 Current Sensor Instructions for installation, use and maintenance
MEDIUM VOLTAGE PRODUCT KECA 250 B1 Current Sensor Instructions for installation, use and maintenance 2 KECA 80 C184; KECA 80 C216 CURRENT SENSORS INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE Scope
More information1ZSE en, Rev. 9. Transformer bushings, type GOB Technical guide
1ZSE 2750-102 en, Rev. 9 Transformer bushings, type GOB Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More information1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide
1ZSE 2750-112 en, Rev. 3 Wall bushings, type GSA-AA Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More information1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide
1ZSE 2750-106 EN, REV. 7 Oil SF 6 bushings type GOEK Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More information1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide
1ZSE 2750-112 EN, REV. 4 Wall bushings type GSA-AA Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More informationFuse switch disconnectors
SWITCHGEAR RBK Fuse switch disconnectors intended for distribution of electricity and protection of electrical equipment against short-circuits and overloads, with industrial fuse links ENERGY SAFELY SWITCHED
More informationTECHNICAL SPECIFICATIONS OF PCC PANEL
S. no. TECHNICAL SPECIFICATIONS OF PCC PANEL Technical parameters AS PER SPECIFICATION CONSTRUCTIONAL FEATURES TO BE FILLED BY THE SUPPLIER 1 Manufacturer s name To be specified by supplier 2 Rated operational
More informationCOMPACT SUBSTATION GUIDE
COMPACT SUBSTATION GUIDE Certificate Number FM35831 1 The substation is a compact enclosure consisting of MV switchgear, a transformer and an LV switchboard located in three separate compartments which
More informationAFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED
PART B-07 TITLE: SERVICE CONNECTIONS SPECIFICTION NO: B-07 INCEPTION DATE: AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) AMENDMENTS / REVISIONS DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED
More informationDURESCA Busbar system. For indoor and outdoor applications, type DE / type DG DURESCA
DURESCA Busbar system For indoor and outdoor applications, type DE / type DG DURESCA DURESCA Busbar system Swiss quality combined with global experience PRODUCT OVERVIEW Moser Glaser General description
More informationPHOENIX CONTACT
Current transformers INTERFACE Data sheet 03359_en_03 PHOENIX CONTACT 20-04-04 Description The PACT Analog current transformers form a complete range of bus-bar, plug-in and winding current transformers
More informationCURRENT TRANSFORMER MODEL N. SS BAND SECURES BRACKET (view of screw clamp band omitted for clarity) 0.25 x 0.50 SLOT (2 PLACES)
MODEL N 4." I.D. PAGE No 1-30 TERMINAL OPTION LEAD WIRE OPTION 6.75 SS BAND SECURES BRACKET (view of screw clamp band omitted for clarity) 0.75 1.36 1.16 5.75 7.00 0. x 0.50 SLOT (2 PLACES) UL 1015 #16
More informationMEDIUM VOLTAGE PRODUCT. KECA 80 C85 Current Sensor Instructions for installation, use and maintenance
MEDIUM VOLTAGE PRODUCT KECA 80 C85 Current Sensor Instructions for installation, use and maintenance 2 KECA 80 C85 CURRENT SENSOR INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE Scope of Contents 2
More informationAIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE
AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE Certificate Number FM35831 APPLICATION Typical Uses and Classification The MSGair switchgear is used in transformer and switching substations mainly
More informationCompact Gas Insulated Switchgear (GIS) up to 145kV 126kV,145kV Compact Gas Insulated Switchgear (GIS)
Compact Gas Insulated Switchgear (GIS) up to 45 6,45 Compact Gas Insulated Switchgear (GIS). Standard: IEC 6703. Typical Feature. Great Breaking Character of Circuit Breaker The circuit breaker adopt the
More informationINTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.
INTRODUCTION The Power Systems 44 kv MiniSub TM is the most compact system at this voltage available. Utilizing a deadfront termination and lightning arrestor setup, it eliminates the line top or side
More informationInductive voltage transformers
Inductive voltage transformers Outdoor operation SF 6 -gas insulated EGF (245 550) kv General description Voltage transformers type EGF are used in high voltage substations within the 245 550 kv range.
More informationInductive voltage transformers
Inductive voltage transformers Outdoor operation SF 6 -gas insulated EGF (245 550) kv General description Voltage transformers type EGF are used in high voltage substations within the 245 550 kv range.
More informationVoltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]
BasisBlock MC 1 Standards and Regulations IEC 62271-200 ; VDE 0671-200 ; BS EN 62271-200 Technical Data MC1-12 MC1-24 Voltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage
More informationExtensible Unit - VCE2a
ELECTRICAL INDUSTRIAL COMPANY (EICo) LUCY SWITCHGEAR Extensible Unit - VCE2a (Sabre) Electrical Industrial Company (EICo) Lucy Switchgear Extensible Unit VCE2a Front Panel: ELECTRICAL INDUSTRIAL COMPANY
More information1. Table of Contents T-LINE. Page. 1. Table for contents Description Current transformers type HF Product Overview 4
T-LINE 1. Table of Contents Page 1. Table for contents 2 2. Description Current transformers type HF 3 3. Product Overview 4 4. Measuring accuracy VA Burden 5 5. Survey chart 0,5 1 3, type HF3A, HF3B and
More informationZinc Oxide Surge Arrester EXLIM R
Zinc Oxide Surge Arrester EXLIM R Protection of switchgear, transformers and other equipment in high systems against atmospheric and switching overs. For use when requirements of lightning intensity, energy
More informationCast resin transformers
Product catalogue Cast resin transformers according to IEC/EN 60076, VDE 0532, DIN 42523 Power range up to 8 MVA Voltage range up to 36 kv Conductor material: copper or aluminum Protection types: IP 00
More informationM-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)
M-RING 24 SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A) Contents General Description Advanced facilities and process Advanced design philosophy Definition of M-RING 24 Standards Service conditions
More information24kV Medium Voltage Switchgear Metal-Enclosed (LSC2A)
M6 24kV Medium Voltage Switchgear MetalEnclosed (LSC2A) GENERAL FEATURES GENERAL DESCRIPTION The structure of the cubicles, of considerable strength, has selfsupporting structure and is made of steel sheet
More informationSafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin
2017 SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin SafeGear Motor Control Center Arc resistant Metal-Clad construction Descriptive Bulletin Table of Contents
More informationB kv Gas-insulated Substations
72.5 145 kv Gas-insulated Substations The increasing demand for electrical power in cities and industrial centres requires the installation of a compact and efficient distribution and transmission network.
More informationInnovac SVS/08 - SVS/ kv modular switchgear
Innovac SVS/08 - SVS/ 3.6-4 kv modular switchgear Product Focus Epoxy resin insulated switchgear in sheet steel enclosure with vacuum interrupters Total reliability in switching, metering and distributing
More informationCable current transformers
Cable current transformers Indoor and outdoor operation JK JKS / JKS-S JK-G / JKS-G JKF JLD Current transformers JK Cable current transformers type JK are used in indoor switchgears. They transform high
More informationInductive voltage transformers
Inductive voltage transformers Outdoor operation SF 6 -gas insulated EGF (245 550) kv General description Voltage transformers type EGF are used in high voltage substations within the 245 550 kv range.
More informationCombined instrument transformers
Combined instrument transformers Outdoor operation Oil-paper insulated EJOF (24 170) kv General description Combined instrument transformers type EJOF are used in high voltage networks within the 24 170
More informationVOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS
VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS A. 11 KV SWITCHGEAR 1.0 SWITCHGEAR ASSEMBLY 1.1 Make : 1.2 Type : 1.3 Reference Standard : 1.4 Voltage (Nom./Max.) KV : 1.5 Phase, Frequency No,Hz.
More informationUniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions
UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions ABB a global leader ABB is a global leader in power and automation technologies that
More informationCurrent transformers. Current transformers
Current transformers Current transformers Moulded case current transformer Moulded case CT, class 1 and 0.5 / 5 A Increased reliability Both halves of the housing overlap rather than butting up against
More informationDPX moulded case circuit breakers
BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.
More informationZinc Oxide Surge Arrester PEXLIM Q
Zinc Oxide Surge Arrester Protection of switchgear, transformers and other equipment in high voltage systems against atmospheric and switching overvoltages. in areas with high lightning intensity and high
More informationHIGH VOLTAGE LABORATORY INSTYTUT ENERGETYKI
HIGH VOLTAGE LABORATORY INSTYTUT ENERGETYKI POLAND 01-330 WARSZAWA, ul. Mory 8, tel. (+48 22) 836-80-48, fax (+48 22) 836-80-48 e-mail: ewn@ien.com.pl EWN/70/E/11-1 APPENDIX 3 APPENDIX 3 for test report
More informationenergy management systems Current Transformers
energy management systems 05 Current Transformers CURRENT TRANSFORMERS Current transformers with analogue output page 5/1 Busbars page 5/5 Current transformers ic Line page 5/6 Protective current transformers
More informationCPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards
Medium Voltage Switchgear Primary Distribution CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka General description Presentation Ormazabal s CPG System includes the CPG.1
More informationKuhlman Electric Corporation. Engineered Designs Instrument Transformers
Kuhlman Electric Corporation Engineered Instrument Transformers Engineered Table of Contents Description Model Page Slipover CT/ACCUSlip TM Single, Dual & Multi Ratio (High Accuracy Available) PS-981/PH-982
More informationCurrent transformers. Outdoor operation SF 6 -gas insulated. JGF ( ) kv
Current transformers Outdoor operation SF 6 -gas insulated JGF (245 550) kv General description Current transformers type JGF are used in high voltage switchgear within the 245 550 kv range. They transform
More informationIndex. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.
Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv
More informationMedium-Voltage Switchgear and Switches
edium-voltage Switchgear and Switches G edium-voltage Switchgear up to 6 kv, 2.500A Product overview Switchgear for primary distribution level type CPG.0, CPG.1, AC Switchgear for secondary distribution
More informationTGK Prefabricated Substation Technical Data
TGK Prefabricated Substation Technical Data Ref Item Data 1 General Technical 1.1 Frequency (Hz) 50 1.2 Transformer Rating (kva) 315/750 1.3 Transformer Primary Voltage (kv) 11 1.4 Transformer Secondary
More informationInstrument Transformer Reference. Meter and Relay Applications for the Electrical Industry
Instrument Transformer Reference Meter and Relay Applications for the Electrical Industry Note: For Current and Voltage Transformer Pricing Information refer to: 600 V -PL 42-800 5 kv-36 kv -PL 42-900
More informationMetal Clad Switchgears
SNC Series Metal Clad Switchgears > up to 36 kv Rated Voltage > up to 2500 A Rated Current > up to 40 ka Rated Short Time Withstand Current > LSC-2B, PM, AFLR > In Confirmity with IEC 62271-1, 100, 102,
More informationBenefits, typical uses
R-HA26-013. eps Switchgear Type 8BT1, up to 24kV,Air-Insulated Contents Application Page Application Benefits 2 Typical uses 2 and 3 Technical Data Ratings 4 Classification, dimensions, 5 room planning
More informationUnitole UP kv Primary substations Motor control centres
Unitole UP 3.6-17.5 kv Primary substations Motor control centres Product Focus Air-insulated withdrawable switchgear with vacuum circuit-breakers and contactors Creating Solutions Eaton Holec creates power-engineering
More informationSWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT
SWITCHCRAFT Switchcraft Europe GmbH Switchgear Product Overview igis Gas Insulated Switchgear isis Solid Insulated Switchgear icb - Vacuum Circuit Breaker iair - Air insulated switchgear panel Switchcraft
More informationFault management for grid automation Advanced fault location solution
Fault management for grid automation Advanced fault location solution 2 FA U LT M A N A G E M E N T F O R G R I D A U T O M AT I O N Power distribution systems are undergoing a major evolution with distributed
More informationProduct Specification
KYN28-12 Series H.V Metal Clad Switchgear Product Specification 10/08/2015 Electrical Treasure One-Stop Supplier Of Electrical Equipment 1 KYN28-12 Series With Prevent Wrong Operation Of Metal Clad Switchgear
More informationSwitchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.
www.siemens.com/medium-voltage-switchgear Switchgear Type 8BT1, up to 24 kv, air-insulated Medium Voltage Switchgear Catalog HA 26.31 2012 Answers for infrastructure and cities. R-HA26-013. eps Contents
More informationMetal Clad VCBs ~ Mk1
Metal Clad VCBs ~ Mk1 DUVI 150/40 ROLL ON FLOOR VCBs Range: 6kV, 00A, 1.5kA, 12kV, 150A, 40kA ( 4A000A Bus-Bars ) ` Widest range for MV (up to 6kV) Distribution Networks Megawin make metal clad VCB Panels
More informationInductive voltage transformers
Inductive voltage transformers Outdoor operation Oil-paper insulated EOF (24 245) kv General description Voltage transformers type EOF are used in high voltage networks within the 24 245 kv range. They
More informationInductive voltage transformers
Inductive voltage transformers Outdoor operation Oil-paper insulated EOF (24 245) kv General description Voltage transformers type EOF are used in high voltage networks within the 24 245 kv range. They
More informationMulti-purpose percentage restraint differential protection
Multi-purpose percentage restraint Page 1 Issued June 2002 Changed since June 1999 Data subject to change without notice (SE970169) Features Complete phase and earth fault protection for generators, motors,
More informationBasic Series Accessories Low Voltage Current Transformer Class 1
Low Voltage Current Transformer Class 1 Current Transformer Current transformers for direct mounting to bus bars or insulated round conductors. Application: indirect measurement of sinusoidal alternating
More informationMedium Voltage Products. KEVA 24 B20; KEVA 24 B21 Voltage Sensors Instructions for installation, use and maintenance
Medium Voltage Products KEVA 24 B20; KEVA 24 B21 Voltage Sensors Instructions for installation, use and maintenance Instructions for installation, use and maintenance for the KEVA 24 B20 and KEVA 24 B21
More informationType SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear
Circuit-Breaker www.siemens.com/energy Switchgear Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear s Technology Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated
More informationInductive voltage transformers
Inductive voltage transformers Outdoor operation Oil-paper insulated EOF (24 245) kv General description Voltage transformers type EOF are used in high voltage networks within the 24 245 kv range. They
More informationENYSTAR Load Centers up to 250 A
PASSION FOR POWER. up to 250 A according to IEC 61439-3 for commercial and industrial buildings Download at www.hensel-electric.en made in GERMANY since 1931 up to 250 A according to IEC 61439-3 for commercial
More informationwith Vacuum Circuit Breaker HAF
M E T A L - C L A D S W I T C H G E A R Safety and Reliability with Vacuum Circuit Breaker HAF Flexible Design and Compact with Vacuum Circuit Breaker HVF Easy Installation and Maintenance We build a better
More informationDescriptive bulletin. ReliaGear ND ANSI narrow frame metal-clad switchgear
Descriptive bulletin ReliaGear ND ANSI narrow frame metal-clad switchgear Table of contents Introduction...3 Vmax/A breaker...4 Instrument transformers...5 Potential transformers...6 15 kv potential transformers...6
More informationValid for you. medium voltage switchgear
Valid for you. medium voltage switchgear VEO knows your needs VEO s field of expertise is energy. We provide customised automation and electrification solutions for customers in the power generation, distribution
More informationI B D Q I B D Q O I B D Q O
Extension offer: new possible combinations 2 and 3 functions RM6 free combination: offers all types of configurations which fit to every application. Free choice: type of each functional unit. Free choice:
More informationMESG 12 / 17.5 / 24 / 36 KV
MESG 12 / 17.5 / 24 / 36 KV Medium Voltage Air Insulated Metal Enclosed Switchgear up to 36 kv- up to 1250 A - up to 25 ka for 1 sec. with SF6 or vacuum circuit breakers. 750 METAL ENCLOSED 1 1 ) GENERAL
More informationOutdoor load disconnectors DRIBO Flc GB. three-pole design rated voltage 25 and 38.5 kv rated current 630 A
Outdoor load disconnectors three-pole design rated voltage 25 and 38.5 kv rated current 630 A outdoor load disconnectors The breaking operation at the load disconnectors uses the energy of spring-based
More informationYOUR KEY ENERGY EFFICIENCY PARTNER CAST RESIN DRY-TYPE TRANSFORMERS
YOUR KEY ENERGY EFFICIENCY PARTNER CAST RESIN DRY-TYPE TRANSFORMERS 1 TABLE OF CONTENTS ABOUT SVEL GROUP CAST-RESIN TRANSFORMERS ACCESSORIES AND OPTIONAL EQUIPMENT ENCLOSURE AND HOUSING TESTS AND QUALITY
More informationSABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS
SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS Design The Sabre VRN2a is a compact SF6 insulated Vacuum Ring Main Unit (RMU). The unit can be mounted to the smallest distribution transformer or be sited in
More informationApplications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders
Applications HV HRC (high-voltage high rupturing capacity) fuses are used for short circuit protection in high-voltage switchgear for the 50 to 60 Hz frequency range Distribution transformers up to 2000
More informationSafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin
SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin Contents 1. Introduction 2 2. Product highlights 2 3. Available configuration/competitive
More informationKYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS
KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS 2001.09 KYN28A-12 (GZS1) A.C Metalclad Removable Switchgear for Indoor Use --------The Leader in Switchgear Up to 12kV 1. The
More information