The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

Similar documents
CEW SERIES CEILING EXPOSED HORIZONTAL FAN COIL UNITS

FFW/FSW/FHW SERIES FLOOR EXPOSED VERTICAL FAN COIL UNITS

BVX SERIES VERTICAL DIRECT EXPANSION BLOWER COIL UNITS

F SERIES. Floor Exposed Vertical Fan Coil Units. Nominal Sizes 200 thru 1200 CFM

42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application

Complete HVAC Capability

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL

Product Data. 42D Ducted Fan Coil Air Conditioners cfm

BHH Product Specifications

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

FS Fan-Coil Units Hi-Rise, Vertical

HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

Horizontal and Vertical BELT DRIVE AIR HANDLING UNITS

DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE

RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION FEATURES MODELS: AHR18 THRU 60* WARRANTY

ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

TVS/R FAN COIL UNITS HI-RISE, VERTICAL

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION

RBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION FEATURE

Submittal 30 [762] 36 [914] 40 [1016] 50 [1270] 60 [1524] 70 [1778]

Submittal. Front View Side View

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)

ELITE SERIES R-410A Ready - Multi-Position

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

RAH Engineering Guide

Hi-Performance Series Fan Coil Technical Catalog

FCVC Series VERTICAL FAN COILS

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH

FN Fan-Coil Units High-Performance, Horizontal

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz

Horizontal Fan Coils 200-1,200 CFM

CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

SINGLE PACKAGE AIR CONDITIONING WATER COOLED

DECORATIVE FAN COIL UNIT DECORATIVE FAN COIL UNIT SPECIFICATIONS

Climas y Proyectos Leyco, S.A. de C.V.

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

catalog SDL Single-Duct, Low-Height, VAV Terminals

CHP

GP7RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner, Single Phase WARRANTY

Product Data. 40RUQ SplitSystemHeatPump Indoor Unit (Air---Handling Unit) With Puron R Refrigerant 60 Hz FEATURES/BENEFITS

VAHU Vertical Air Handling Unit

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS

PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS

RCD Air Cooled Condensing Unit (50/60 Hz)

Vertical Stack Fan Coils 300-1,200 CFM

ARUF Series. Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons. Contents. Product Features

FAN POWERED TERMINAL UNITS

OmegaAir Series Dedicated Outside Air Systems (DOAS) Engineering Guide

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

HORIZONTAL HIGH CAPACITY FAN COIL UNITS DUCTED

catalog SDL Single-Duct, Low-Height, VAV Terminals

Typical Applications. Horizontal Installation

BAC / BHC Product Specifications

Product Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons

A Division of Nailor International Inc. ECONOMY AIR HANDLERS

Product Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A)

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Product Data. 40RUA / 40RUS 6to30TonDirectExpansionwithPuron R Refrigerant 7.5to30TonChilledWater Packaged Air---Handling Units 60 Hz

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016

MERIT Series R-410A - Upflow / Horizontal - Variable Speed

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

#7 Stock Cabinet Fan/Coils

Concealed Ducted Split Series R22

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6-25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Unitary Products. Magic Aire Specifications Manual. Producing Quality Heating & Cooling Equipment For Over 50 Years

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h

Tons BTU/h S.E.E.R* E.E.R** HSPF

SDL Single-Duct, Low-Height, VAV Terminals

Horizontal Series Fan Coil Technical Catalog

T VB FA N COIL U NIT S F LO OR -MOU NT E D, V E RT ICA L

AWUF, AWUT Series. Wall-Mount Air Handler 1½ to 3 Tons. Contents. Product Features

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.

GENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

DESCRIPTION FEATURES

B6VMMX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler with TXV 18,000-60,000 Btuh (Heat Pump & Air Conditioner)

Transcription:

Producing Quality Heating & Cooling Equipment For Over 50 Years CEA SERIES CEILING EPOSED HORIZONTAL FAN COIL UNITS The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat MAGIC AIRE CE SERIES FAN COILS ARE ETL LISTED TO U.S. AND CANADIAN SAFETY STANDARDS AND ARE ASSEMBLED TO ORDER FOR COMPETITIVE DELIVERY. United Electric Company, L.P. 501 Galveston St. Wichita Falls, T 76301 940-397-20 Fax: 940-397-2166 www.magicaire.com 0

CE Series Decorative, slim cabinet designed for exposed ceiling applications. Unit includes double deflection discharge grille. Cabinet is galvanealed steel with baked powder Polar Ice color coating for the ultimate in durability. All panels are lined with acoustic and thermal glass fiber insulation. Filters are one inch throwaway and are accessed through the hinged bottom service panel. Optional mixed air damper for 0% outside air requirements. 6" KNOCKOUTS FOR PIPING REAR MOUNTING HOLES 4 SUPPLY AIR BOTTOM RA, REAR OA (OPTIONS D AND F ) B DAMPER 8.5" HINGED SERVICE ACCESS PANEL (TYP) FILTER (TYP) STAMPED RA LOUVER 3" 2" FRONT A SUPPLY AIR BOTTOM RA, TOP OA (OPTIONS E AND G ) B TOP OA DUCT COLLAR DAMPER TOP VIEW STAMPED RA LOUVER 12" REAR RA ONLY (OPTION R ) B FRONT VIEW SUPPLY AIR KNOCKOUTS FOR PIPING RA GRILLE REAR OPTIONAL OA DUCT COLLAR SOLID BOTTOM AND ACCESS PANEL BOTTOM RA ONLY (OPTION B ) B1 DIMENSIONS MODEL A B B1 SHIPPING WEIGHT FILTER SIZE OPTIONAL DISC. DUCT CONN. OPTIONAL REAR DUCT CONN. CEA02 33" 36" 28" 2 x 18 x 1 6.75 x 15 8.5 x 18 CEA04 33" 36" 28" 9 x 18 x 1 6.75 x 18 8.5 x 18 CEA06 42" 36" 28" 7 x 27 x 1 6.75 x 27 8.5 x 36 CEA08 51" 36" 28" 155 x 36 x 1 6.75 x 36 8.5 x 36 CEA 60" 36" 28" 171 x 45 x 1 6.75 x 45 8.5 x 45 CEA12 69" 36" 28" 225 x 54 x 1 6.75 x 54 8.5 x 54 ALL COIL CONNECTIONS 5/8" O.D. SWT. ALL DRAIN CONNECTIONS 3/4" M.P.T. SUPPLY AIR NOTES: 1. Legend: RA = Return Air OA = Outside Air 2. Refer to Nomenclature page for cabinet options. Refer to Coil Option Schedule for available coil combinations. 3. For cabinet options E and G, damper function is 0-50% RA and 50-0% OA nominal. STAMPED RA LOUVER AND FILTER Page 2

GUIDE SPECIFICATIONS Magic Aire Fan Coil Unit HVAC Guide Specifications Size Range: 200 to 1200 Nominal CFM Magic Aire Model CE Part 1 General 1.01 SYSTEM DESCRIPTION Horizontal, 2-pipe or 4-pipe, room fan coil unit with painted finish cabinet for exposed installation or ducting. 1.02 QUALITY ASSURANCE Unit shall be tested in accordance with ARI Standard 440 and base unit ETL certified. Each coil shall be factory tested for leakage at 450 psig air pressure with coil submerged in water. Insulation and adhesive shall meet NFPA-90A requirements for flame spread and smoke generation. All equipment wiring shall comply with NEC requirements. 1.03 DELIVERY, STORAGE AND HANDLING Each unit shall be individually packaged from point of manufacture. Unit shall be handled and stored in accordance with the manufacturer s instructions. Part 2 Product 2.01 EQUIPMENT General: Factory-assembled, horizontal, blow-thru type fan coil for exposed ceiling or ducted installations. Unit shall be complete with water coil(s), fan(s), motor(s), drain pan, and all required wiring, piping, controls and special features. A. Base Unit: 1. Casing to consist of heavy gauge galvanized steel insulated with 1/2 fiberglass Tufskin insulation. Units shall pass 500 hour salt spray test as described in ASTM B-117. 2. Cabinet shall include a removable bottom access panel with stamped return-air grille or ducted return air, filter rack and 1-in. fiberglass throwaway filter. The panel shall be fastened with slotted head, positive-locking quarter-turn fasteners. The cabinet shall be coated with a Polar Ice baked finish. 3. The drain pan shall be constructed of galvanized steel extending the entire length and width of the coil(s) and shall be pitched for drainage. The drain connection shall be ¾ FPT. B. Fans: Direct-driven, double-width fan wheels with forward curved blades shall be statically and dynamically balanced. The housing shall be constructed of heavy gauge galvanized steel with die-formed inlet cones. Fan wheels shall be constructed of galvanized steel. C. Coils: 1. Standard base unit shall be equipped with a 3-row, 4-row or 5-row coil for installation in a 2 or 4-pipe system. Hydronic coil options include split heating/cooling coils in combinations not exceeding 5 rows. 2. Factory installed electric resistance heating coils in may be 1.5 to kw depending on unit size and voltage. 3. All coils shall have 3/8-in. copper tubes and aluminum fins. Coil fins are mechanically bonded to tube joints. The copper tubes comply with the ASTM B-75. The fin thickness is 0.0045-in and tube thickness is 0.0-in. All coils are tested with air under water. 4. Unit with electric heat shall have electric resistance heaters mounted on the entering air side of the water coil. Heaters shall include high limit cutout with auto reset and contactor. 5. When fan motor and electric heater are selected at the same voltage and connected to a single power source, a junction box and fuse shall be factory furnished and installed to protect the motor and control circuit. D. Controls and Safeties: Unit shall be furnished with an optional 3-speed, 4-position fan switch on a wall plate for field mounting. The fan motor(s) shall be equipped with integral automatic temperature reset for motor protection. E. Operating Characteristics: 1. A unit with single hydronic coil installed in a 2-pipe system shall be capable of providing heating or cooling as determined by the operating mode of the central water supply system. 2. A unit with two hydronic coils installed in a 4-pipe system shall be capable of providing heating and cooling, controlled as determined by field-provided and installed valves and controls. 3. Electrical Requirements: The unit power supply shall be single phase, 60 Hz. The standard unit is 120 volt, but 208/240V and 277V options are available. F. Motor(s): Fan motors shall be 3-speed; permanent split capacitor type, with sleeve type bearings and factory-sealed oil reservoirs to ensure lubrication. Page 3

MODEL NOMENCLATURE CEA Model Number Nomenclature Position 1 2 3 4 5 6 7 8 9 11 12 13 Example C E A 0 6 B A R A 1 A A A M Model Series M -- Not Used CEA-- Horizontal Direct Drive Unit, Uncased DRAIN PAN OPTIONS A -- Galvanized Unit Size Nominal Tons B -- Stainless Steel 02 -- 04 -- 200 CFM 400 CFM 0.5 1.0 RETURN AIR CABINET 06 -- 600 CFM 1.5 B -- Bottom Return Only 08 -- 800 CFM 2.0 Bottom Return Air/Rear Outside Air w/o D -- -- 00 CFM 2.5 Actuator 12 -- 1200 CFM 3.0 Bottom Return Air/Top Outside Air w/o E -- Actuator PRIMARY COIL TYPE AND CAPACITY Bottom Return Air/Rear Outside Air with F -- Type Rows Metering Actuator 0 -- None N/A N/A Bottom Return Air/Top Outside Air with G -- B -- 3 N/A Actuator C -- Chilled Water/2-Pipe 4 N/A R -- Rear Return Only D -- 5 N/A CONTROLS HEATING COIL A -- Junction Box Only Type Rows B -- 24V Fan Control A -- None N/A C -- 24V Fan Control w/ Svc Disconnect Switch 1 -- 1 D -- Svc Disconnect Switch Only Hot Water 2 -- 2 E -- 24V Control + Timer Electric Heat F -- 24V Control + Timer + Svc Disconnect Switch Nominal kw kw @ 208V CONTROLS NOTES: B-- 1.5 kw 1.1 kw 1. Svc disconnect switch is for non-electric heat C-- 2.0 kw 1.5 kw units only. D-- E-- 2.5 kw 3.0 kw 1.9 kw 2.3 kw MOTOR POWER SUPPLY F-- 4.0 kw 3.0 kw 1 -- 120/1/60 G-- 5.0 kw 3.8 kw 2 -- 208/240/1/60 Std. Static H-- 6.0 kw 4.5 kw 3 -- 277/1/60 J-- 8.0 kw 6.0 kw 4 -- 120/1/60 K--.0 kw 7.5 kw 5 -- 208/240/1/60 High Static HEATING COIL NOTES: MOTOR POWER SUPPLY NOTES: 1. Refer to CE Option Schedule for available combinations. 2. Electric heat controls shall be wired at 240V by factory. Field must switch transformer tap for 208V operation. 3. Maximum of 5 total rows allowed (cooling coil rows plus heating FUTURE USE coil rows). A -- Not Used 4. Nominal kw is at 240V. 208V heaters are derated from 240V. 1. Unit shall be wired for 240V at factory. switch transformer tap (if provided) to 208V. Field must CE Electric Heat Schedule COIL CONFIGURATION Nominal kw Heat Position Connection Hand Unit Size (120V Only) (208/240V Only) A -- Right Hand (Cooling & Heating Coil) or N/A 1.5 2.0 2.5 3.0 4.0 5.0 6.0 8.0.0 L -- Left Hand (Cooling & Heating Coil) Pre-Heat 02 M -- Opp Cnx- Right Hand Cooling 04 N -- Opp Cnx- Left Hand Cooling 06 R -- Right Hand (Cooling & Heating Coil) 08 S -- Left Hand (Cooling & Heating Coil) Re-Heat T -- Opp Cnx- Right Hand Cooling 12 U -- Opp Cnx- Left Hand Cooling Electric heat not available for 277V. COIL CONFIGURATION NOTES: 1. Electric heat is available only in Pre-Heat. 2. "Left Hand" and "Right Hand" defined as looking at the filters in the direction of airflow. Page 4

CE Series COIL OPTION SCHEDULE Configuration CHW/HW CHW/EH Unit Sizes 02-12 02-04 06-12 3-Row Cooling Coil/2-Pipe 4-Row CE Coil Option Schedule HW Heating Coil (4-Pipe) 5-Row None 1-Row 2-Row 1.5 2.0 2.5 3.0 4.0 5.0 6.0 8.0.0 (120V Only) Notes: 1. Legend: CHW Chilled Water HW Hot Water EH Electric Heat 2. Option Schedule indicates available combinations. Refer to nomenclature to specify unit for order. 3. Electric heat not available for 277V. 4. Electric heat - select one option. 5. Coil options: 3 row minimum coil required; 5 rows total maximum; 4-pipe unit configurations are "split" style coils with both coils in same finblock and are available in 1/3, 1/4, and 2/3 arrangements, preheat or reheat. Electric Heat - Nominal kw (208/240V Only) Page 5

CE Series ELECTRICAL DATA CHA - CEA Electrical Data - 120V UNIT SIZE 02 04 06 08 Voltage MOTOR HP 1/15 1/ hi-static 1/ 1/8 hi-static 1/8 1/4 hi-static 1/ x 2 1/8 x 2 hi-static MOTOR FLA 120 0.75 1.1 TOTAL ELECTRIC HT (KW) 120 1.5 2 2.5 1.5 2 ELECTRIC HEAT AMPS 120 12.5 16.7 20.8 12.5 16.7 2.5 20.8 MINIMUM UNIT FLA CIRCUIT AMPACITY 120 120 0.8 0.9 13.3 16.6 17.4 21.8 21.6 27.0 1.1 1.4 13.6 17.0 17.8 22.2 21.9 27.4 Maximum Overcurrent PD (A) 120 15 20 25 30 15 20 25 30 1.4 1.4 1.8 15 1.6 1.6 2.0 15 1.8 1.8 2.3 15 3.1 3.1 3.9 15 1.4 2.8 3.5 15 12 *2 1.6 3.8 4.8 15 Notes: *1. Minimum Wire Gauge is based upon 75C wire at the unit. On 208/240V units the size is based upon the 240V Ratings. 2. Size 12 units have two fan motors. MIN WIRE SIZE AWG* 1 12 12 Page 6

CE Series ELECTRICAL DATA CHA - CEA Electrical Data 208/240V UNIT SIZE MOTOR HP MOTOR FLA TOTAL ELECTRIC HT (KW) ELECTRIC HEAT AMPS UNIT FLA MINIMUM CIRCUIT AMPACITY Maximum Overcurrent PD (A) Voltage 240-208V 240 208 240 208 240 208 240 208 240 208 02 1/ hi-static 0.6 0.6 0.6 0.8 0.8 15 15 0.5 0.5 0.6 0.6 15 15 1/15 3 2.25 12.5.8 13.0 11.3 16.3.2 20 15 12 0.5 4 3.00 16.7.4 17.2.9 21.5 18.7 25 20 04 5 3.76 20.8 18.1 21.3 18.6 26.7 23.2 30 25 0.6 0.6 0.8 0.8 15 15 1/ 3 2.25 12.5.8 13.1 11.4 16.4.3 20 15 12 0.6 hi-static 4 3.00 16.7.4 17.3 15.0 21.6 18.8 25 20 5 3.76 20.8 18.1 21.4 18.7 26.8 23.3 30 25 0.6 0.6 0.8 0.8 15 15 3 2.25 12.5.8 13.1 11.4 16.4.3 20 15 12 1/ 4 3.00 16.7.4 17.3 15.0 21.6 18.8 25 20 0.6 5 3.76 20.8 18.1 21.4 18.7 26.8 23.3 30 25 6 4.51 25.0 21.7 25.6 22.3 32.0 27.8 35 30 8 06 8 6.01 33.3 28.9 33.9 29.5 42.4 36.9 45 40 8 0.8 0.8 1.0 1.0 15 15 3 2.25 12.5.8 13.3 11.6 16.6.5 20 15 12 1/8 4 3.00 16.7.4 17.4 15.2 21.8 19.0 25 20 0.77 hi-static 5 3.76 20.8 18.1 21.6 18.8 27.0 23.5 30 25 6 4.51 25.0 21.7 25.8 22.4 32.2 28.0 35 30 8 8 6.01 33.3 28.9 34.1 29.7 42.6 37.1 45 40 8 0.9 0.9 1.1 1.1 15 15 3 2.25 12.5.8 13.4 11.7 16.8.7 20 15 12 4 3.00 16.7.4 17.6 15.3 22.0 19.2 25 20 1/8 0.9 5 3.76 20.8 18.1 21.7 19.0 27.2 23.7 30 25 6 4.51 25.0 21.7 25.9 22.6 32.4 28.2 35 30 8 8 6.01 33.3 28.9 34.2 29.8 42.8 37.2 45 40 8 08 7.51 41.7 36.1 42.6 37.0 53.2 46.3 60 50 6 1.6 1.6 2.0 2.0 15 15 3 2.25 12.5.8.1 12.4 17.6 15.5 20 20 12 4 3.00 16.7.4 18.3 16.0 22.8 20.1 25 25 1/4 1.6 5 3.76 20.8 18.1 22.4 19.7 28.0 24.6 30 25 hi-static 6 4.51 25.0 21.7 26.6 23.3 33.3 29.1 35 30 8 8 6.01 33.3 28.9 34.9 30.5 43.7 38.1 45 40 8 7.51 41.7 36.1 43.3 37.7 54.1 47.1 60 50 6 1.2 1.2 1.5 1.5 15 15 1/ x 2 6 4.51 25.0 21.7 26.2 22.9 32.8 28.6 35 30 8 0.6 8 6.01 33.3 28.9 34.5 30.1 43.2 37.6 45 40 8 7.51 41.7 36.1 42.9 37.3 53.6 46.6 60 50 6 12 *2 1.5 1.5 1.9 1.9 15 15 1/ x 2 6 4.51 25.0 21.7 26.5 23.2 33.2 29.0 35 30 8 0.77 hi-static 8 6.01 33.3 28.9 34.9 30.4 43.6 38.0 45 40 8 7.51 41.7 36.1 43.2 37.7 54.0 47.1 60 50 6 Notes: *1. Minimum Wire Gauge is based upon 75C wire at the unit. On 208/240V units the size is based upon the 240V Ratings. 2. Size 12 units have two fan motors. MIN WIRE SIZE AWG* 1 Page 7

CE Series ELECTRICAL DATA CHA - CEA Electrical Data 277V UNIT SIZE 02 04 06 08 Voltage MOTOR HP 1/15 1/ 1/8 12 *2 1/ x 2 MOTOR FLA 277 TOTAL ELECTRIC HT (KW) ELECTRIC HEAT AMPS UNIT FLA MINIMUM CIRCUIT AMPACITY Maximum Overcurrent PD (A) 277 277 277 277 277 0.4 0.4 0.5 15 0.6 0.6 0.8 15 0.83 0.8 1.0 15 0.6 1.2 1.5 15 Notes: *1. Minimum Wire Gauge is based upon 75C wire at the unit. On 208/240V units the size is based upon the 240V Ratings. 2. Size 12 units have two fan motors. MIN WIRE SIZE AWG* 1 Page 8

CE Series AIR FLOW Unit Size 02 04 06 08 12 CHA and CEA Blower Performance Standard Static Unit -Dry Coil ESP High Speed Airflow (CFM) 3-ROW 4-ROW 5-ROW 0. 265 255 240 0.15 235 225 2 0.20 2 190 180 0.25 165 155 150 0.30 125 120 1 0. 4 385 370 0.15 380 360 335 0.20 350 325 300 0.25 3 280 260 0.30 260 235 220 0. 595 565 530 0.15 550 530 480 0.20 500 460 425 0.25 430 395 355 0.30 350 320 300 0. 840 800 750 0.15 785 745 700 0.20 730 680 630 0.25 665 6 565 0.30 575 535 500 0. 905 850 800 0.15 840 785 735 0.20 750 705 660 0.25 675 635 600 0.30 580 550 5 0. 1190 1130 60 0.15 10 60 960 0.20 00 920 850 0.25 860 790 7 0.30 700 640 600 BLOWER CORRECTION FACTOR Unit Size (Standard Static Units) Fan Speed High Med Low 02 1.00 0.90 0.80 04 1.00 0.90 0.80 06 1.00 0.95 0.91 08 1.00 0.95 0.91 1.00 0.90 0.80 12 1.00 0.95 0.91 For airflow data at medium and low speed, multiply standard static airflow by correction factor. Page 9

CE Series AIR FLOW CHA and CEA Blower Performance High Static Unit -Dry Coil Unit Size ESP High Speed Airflow (CFM) 3-ROW 4-ROW 5-ROW 0.20 368 346 328 0.25 352 331 3 0.30 335 316 300 0.35 319 300 285 02 0.40 301 281 270 0.45 283 267 254 0.50 265 250 238 0.55 245 232 222 0.60 225 213 205 0.20 519 486 449 0.25 500 468 432 0.30 481 449 413 0.35 460 429 394 04 0.40 438 408 374 0.45 415 386 353 0.50 391 362 330 0.55 364 337 306 0.60 334 309 280 0.20 747 701 663 0.25 719 675 638 0.30 691 647 611 0.35 661 619 584 06 0.40 629 589 556 0.45 596 557 526 0.50 562 524 494 0.55 525 489 461 0.60 485 452 425 0.20 32 974 9 0.25 995 940 880 0.30 957 904 846 0.35 917 866 8 08 0.40 875 827 772 0.45 832 786 733 0.50 786 743 692 0.55 737 698 649 0.60 686 649 603 0.20 1236 1162 13 0.25 1193 1121 65 0.30 18 80 26 0.35 12 37 985 0.40 54 993 943 0.45 05 947 900 0.50 953 899 855 0.55 900 849 808 0.60 844 797 759 12 Double Size 06 Performance Page

3 ROW CHILLED WATER COOLING CAPACITIES LWT LWT LWT CHA12 - CEA12 CHA - CEA CHA08 - CEA08 CHA06 - CEA06 CHA04 - CEA04 CHA02 - CEA02 Page 11

4 ROW CHILLED WATER COOLING CAPACITIES LWT LWT LWT CHA12 - CEA12 CHA - CEA CHA08 - CEA08 CHA06 - CEA06 CHA04 - CEA04 CHA02 - CEA02 Page 12

1 ROW HEATING 2 ROW HEATING CHA12 - CEA12 CHA12 - CEA12 CHA - CEA CHA - CEA CHA08 - CEA08 CHA08 - CEA08 CHA06 - CEA06 CHA06 - CEA06 CHA04 - CEA04 CHA04 - CEA04 CHA02 - CEA02 CHA02 - CEA02 Page 13

3 ROW HEATING CHA - CEA CHA12 - CEA12 CHA06 - CEA06 CHA08 - CEA08 CHA02 - CEA02 CHA04 - CEA04 Entering Air Temp (F) HOT WATER HEATING CORRECTION FACTORS Entering Water Temp (F) o 0 1 o o 120 130 o 0 o o 150 160 o 170 o 80 50 o. 419. 500. 579. 665. 742. 838. 917 1.000 1.090 55 o. 376. 460. 544. 629. 708. 791. 873. 963 1.048 60 o. 335. 419. 500. 579. 665. 742. 838. 917 1.000 65 o. 290. 376. 460. 544. 629. 708. 791. 873.963 70 o. 251. 335. 419. 500. 579. 665. 742. 838.917 75 o. 205. 290. 376. 460. 544. 629. 708. 791.873 80 o. 167. 251. 335. 419. 500. 579. 665. 742.838 1 o Page

4 ROW HEATING CHA - CEA CHA12 - CEA12 CHA06 - CEA06 CHA08 - CEA08 CHA02 - CEA02 CHA04 - CEA04 Entering Air Temp (F) HOT WATER HEATING CORRECTION FACTORS Entering Water Temp (F) o 0 1 o o 120 130 o 0 o o 150 160 o 170 o 80 50 o. 419. 500. 579. 665. 742. 838. 917 1.000 1.090 55 o. 376. 460. 544. 629. 708. 791. 873. 963 1.048 60 o. 335. 419. 500. 579. 665. 742. 838. 917 1.000 65 o. 290. 376. 460. 544. 629. 708. 791. 873.963 70 o. 251. 335. 419. 500. 579. 665. 742. 838.917 75 o. 205. 290. 376. 460. 544. 629. 708. 791.873 80 o. 167. 251. 335. 419. 500. 579. 665. 742.838 1 o Page 15

CEA COIL CONNECTION DIMENSIONS Left Hand Shown (Right Hand is Mirror Image) 3.688 A 3, 4, 5 Row Coil 4.125 S R C B 3.688 3-1, 4-1, 3-2 Split Coil D 3.688 E 1-3, 1-4, 2-3 Split Coil 1.750 R 4.125 4.125 R 1.750 S R S R 2.250 S S 2.250 S SUPPLY R RETURN CHILLED WATER HOT WATER CEA UNIT SIZE COIL A B C D E 3 ROW 5.438 4 ROW 6.313 5 ROW 7.188 02 THROUGH 12 3-1 ROW 4.500 6.250 4-1 ROW 4.500 7.125 3-2 ROW 5.375 7.125 1-3 ROW 5.438 6.313 1-4 ROW 6.313 7.188 2-3 ROW 5.438 7.188 Page 16

Page 17

Engineering Specifications United Electric Company designs and manufactures its Magic Aire products in accordance with the following standards: AIR FLOW General AMCA 2 ASHRAE 51 COIL CAPACITY Hydronic Direct Expansion ARI 4 ARI 2 SAFETY AGENCY LISTINGS Equipment ANSI/UL-1995-2003 MATERIAL SPECIFICATIONS MAJOR COMPONENTS Sheet Metal Copper Tubing Aluminum Motors Wire Electrical Filters Fiberglass Paint ASTM A525 ASTM A527 ASTM B68 ASTM B75 ASTM B88 ASTM B251 ASTM B209 UL/CSA NEMA UL/CSA UL/CSA UL ASHRAE 52 UL 181 UL 723 (25/50) ASTM E-84 ASTM B117 MAGIC AIRE CE SERIES FAN COILS ARE ETL LISTED TO U.S. AND CANADIAN SAFETY STANDARDS AND ARE ASSEMBLED TO ORDER FOR COMPETITIVE DELIVERY. United Electric Company, L.P. 501 Galveston St. Wichita Falls, T 76301 940-397-20 Fax: 940-397-2166 www.magicaire.com 0