MP7650 CONTROLLER. Lake-Shore-Electric.com MP7650 Controller STANDARD FEATURES 1.0 INTRODUCTION

Similar documents
Zenith ZTGSE/ZTGDSE. GE Energy Digital Energy. Service Entrance Rated Automatic Transfer Switches. Introduction. Features and Benefits

AREA PROTECTION PANEL

Paralleling Equipment

ASCO Low Voltage Automatic Transfer Switch Systems

Low Voltage Automatic Transfer Switch Systems

Transfer switch OTEC and OTECSE open transition

www. ElectricalPartManuals. com Systems Pow-R Breaker Transfer Switches Technical Data Page 1

DIESEL Engine Fire Pump Controllers Features

SERIES TS AMP AUTOMATIC TRANSFER SWITCHES

Quick Start Guide TS 910 & TS 920

OTPC-SE Service entrance transfer switch open transition

MANUAL ELECTRIC FIRE PUMP CONTROLLERS METRON SERIES M450

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

Mar H: SUPPLEMENTAL PARALLELING GEAR (16315-H)

TECHNICAL SPECIFICATION FOR A 10 TO 50 KVA THREE PHASE, UNINTERRUPTIBLE POWER SYSTEM WaveRider III

DGC-2020 DIGITAL GENSET CONTROLLER

AIR COOLED RECTIFIER SPECIFICATION S-50-A

Bypass/Isolation Switches RTS-03 SERIES

Backup Generation Application

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Diesel generator set QST30 series engine

Bypass Isolation Transfer Switches Amperes

OTEC Transfer switch open transition

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Operator Manual. Transfer Switch. RSS100 and RSS Cummins Inc. All rights reserved. English

Bypass/Isolation Switches RTS-30 SERIES

CHPC Transfer switch closed transition

TS880 AUTOMATIC TRANSFER SWITCHES

Rental Power QSL9 series engine

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

Diesel generator set QSK60 series engine

Quick Start Guide TS 910

DG SYNCHRONIZING &AMF PANEL

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

SERIES TS AMP AUTOMATIC TRANSFER SWITCHES

SECTION MOTOR CONTROL

Transfer switch GTEC open or delayed transition

OpenEVSE - 40A Charging Station

Transfer switch OTPC open, closed, or delayed transition

GENSET CONTROL MODULE A121H / A241H. User selectable time delays for engine start and engine stop (cool down).

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz

BTPC Bypass isolation transfer switch open or closed transition

Diesel Generator set QSK95 series engine

Diesel generator set QSK95 series engine

Operator s Series 300 Generator Paralleling System

Diesel generator set QSK78 series engine

Diesel generator set QSK60 series engine

Diesel Generator set QSK50 series engine 1135 kw-1500 kw 60 Hz EPA emissions

Rental Power 1500 kw. Specification sheet. Description. Features. Options

Generator/Loadbank Quick Connection Tap Box

OHPC/CHPC Transfer Switches

Transfer switch OHPC open or delayed transition

Transfer switch OTEC open or delayed transition

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

PowerCommand. GenSet Controls

DSEULTRA DSE6000 Quick Start Guide Document Number

Diesel Generator set QSK95 series engine

PowerCommand 2100 digital generator set control

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz Data Center Continuous

Diesel generator set QSK60 series engine

PowerCommand 3300 Control Panel. Our Energy Is Working For You.

GENSET CONTROL MODULE A121A / A241A

This specification describes the minimum requirements for a hoist maintenance safeguard (HMS) system for mine hoists.

Diesel generator set QSK60 series engine

Critical Power Switchboards. Selection and Application Guide

SPECIAL SPECIFICATION 5066 Packaged Engine Generator System

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

A. Submit manufacturer's literature and technical data before starting work.

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

SECTION MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK

Diesel generator set QSL9 series engine

PORTABLE CURRENT SOURCE FOR CIRCUIT BREAKER AND MOTOR OVERLOAD TESTING INSTRUCTION MANUAL PI-250B. Release 1.0 April 5, 2013

Cat/DCG-6D1I/07-08/03/Ver 1 Page 2/10

GTEC Transfer switch Open transition

HGM6410/6420 AUTOMATIC GENERATOR MODULE WITH J1939 INTERFACE SOFTWARE MANUAL

ASCO SERIES 185 Power Transfer Switches

GENSET CONTROL MODULE LEVEL 0 A120A. User selectable time delays for engine start and engine stop (cool down).

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

.3 Section Waste Management and Disposal.

I.L T.K. Instructions for Cutler-Hammer MP1 Series Automatic Transfer Switches A



Diesel generator set QSK78 series engine

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

GE 8000-Line Motor Control Centers Mains, Feeders, Incoming Lines C-1

MANUAL ELECTRIC FIRE PUMP CONTROLLERS METRON SERIES MV600

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

O & M Manual for ATC-300/ A (480/600Vac) 3-Position Contactor Based Transfer Switch

SECTION MOTOR CONTROLLERS

PATTERSON PUMP COMPANY

1. AC VOLTS: Displays generator output in voltage. 2. AC FREQUENCY: Displays the speed of the generator set in Hertz.

O & M Manual for ATC A (480/600Vac) ATC Position Contactor Based Transfer Switch

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

50 AMP Smart Energy Management System Model 800 SERVICE MANUAL 50 AMP SMART EMS. 50 Amp EMS Display Panel P/N A I N A I N

Valcom Failsafe Unit. 1620ESv2 SERIES. Operation and Maintenance Manual

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

Push buttons are of two types i) Momentary push button ii) Maintained contact or detent push button

University of Houston Master Construction Specifications Insert Project Name

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

Transcription:

STANDARD FEATURES 1.0 INTRODUCTION The LSEC MP7650 is a sophisticated state of the art, microprocessor based controller. It consists of five major parts: a Power Supply board, a Relay Interface Board, a Main Control Board, Ribbon Cable and a Human Machine Interface Panel. It is designed to operate in the industrial temperature range of -40 to +85 deg C. 1.1 Power Supply The Power Supply (PS) unit accepts a 12-volt dc or 24-volt dc input from any external power source. It is designed to function on starting batteries. Voltage regulation for the power supply is within 2% volts from no load to full load. External voltage sources can vary from 7 volts dc to 36 volts dc without harm to the MP7650 or interruption of its operation. Momentary losses of power will not compromise the efficient operation of the controller. 1.2 Relay Interface Board The Relay Interface Board (RIB) is the electro mechanical interfacing device between the MP7650 microprocessor controls and the power panel and the user interfaces. When the transfer switch is ordered, 12-volt dc or 24-volt dc operation must be selected. Although the power supply will accept any voltage within its range, the relays that populate the Relay Interface Board must be either 12-volt dc or 24-volt dc. 1.3 Main Control Board The Main Control Board (MCB) contains the microprocessor and performs all of the logic necessary to control the transfer switch. It contains a perpetual date and time clock, which is programmed to automatically adjust for leap years and daylight savings time changes. It contains the timers listed in the section marked Setting Timers. All timer, date and time settings are stored in battery backed-up non-volatile memory which can be maintained de-energized for 10 out of 100 years. 1.4 Human Machine Interface Panel The Human Machine Interface Panel consists of a graphic overlay which displays a one-line representation of a transfer switch, ten LED s (Not in Auto, Ground Fault*, Normal Available, Normal Closed, Normal Tripped*, Normal Reverse Power*, Normal Withdrawn*, Emergency Available, Emergency Closed, Emergency Tripped*, Emergency Reverse Power*, Emergency Withdrawn*) to annunciate status of the switch, a two line, 48 character LCD to display transfer switch mode of operation, date, time, timers status, fault condition, exerciser status other pertinent data. Additionally, the HMI Panel contains a keypad, which allows the transfer switch to be programmed. 2.0 OPERATIONAL CONFIGURATION The MP7650 controls the operation of the automatic transfer switch and contains as standard features five modes of operation, six timers, a plant exerciser, and three sets of dry contacts for customer use. 2.1 Modes of Operation There are five modes of operation. Four of which are selectable by using the HMI Panel 1. Automatic 2. Hand Crank

3. Load Test 4. Off/Reset 5. The fifth mode is Fault. In the fault mode, the transfer switch has failed to perform some func- and the trouble is displayed on the HMI Panel LCD tion 2.2 Timers - The six standard timers are: TDES Time Delay Engine Start. This timer is adjustable from 0 to 300 seconds and is factory set at 3 seconds. It is initiated upon sensing the loss of normal power and once timed out will initiate an engine start signal. TDE Time Delay Emergency. This timer is adjustable from 0 to 300 seconds and is factory set at 5 seconds. It is initiated upon the starting of the engine and once timed out will initiate the transfer to the emergency source. TDN Time Delay Neutral. This timer is adjustable from 0 to 300 seconds and is factory set at 3 seconds. It is initiated upon the opening of one source and will inhibit the closing of the oncoming source until it has timed out. Provided on Dual Motor & Insulated Case Transfer Switches only. TDR Time Delay Return. This timer is adjustable from 0.0 to 60.0 minutes and is factory set at 10 minutes. It is initiated upon the restoration of normal power and will inhibit the switch from retransferring to the normal source until it has timed out. If at any time during the timing cycle normal power is not maintained, this timer will be terminated and will be reinitiated when normal power returns. TDEC Time Delay Engine Cool down. This timer is adjustable from 0.0 to 60.0 minutes and is factory set at 10 minutes. This timer is initiated upon the retransfer of the switch to the normal source and will keep the engine running until it has timed out. MRT Minimum Run Timer. This timer is adjustable from 0.0 to 60.0 minutes and factory set at 10 minutes. It is initiated upon the first successful starting of the engine generator set and will keep the engine running until it has timed out. 2.3 Plant Exerciser - The Plant Exerciser operates on a weekly basis and operates as follows: 1. It can be disabled 2. It can be enabled with or without load 3. Any time of day can be selectable as start time 4. Any duration of exercise period is selectable (hh:mm) from 00:01 through 24:00 Any day or days of the week (SMTWTFS) are selectable for exercising. Any week of the month (12345) is selectable for exercising. 2.4 Pilot Lights - The following LED s are provided in the MP7650: NOR Normal Source Available NAW *Normal Switch Withdrawn EMR Emergency Source Available EAW *Emergency Switch Withdrawn SIN Switch in Normal EAT *Emergency Switch in Test SIE Switch in Emergency NAT *Normal Switch in Test NIA Not in Automatic NT *Normal Tripped ET *Emergency Tripped GF *Ground Fault

RPN RPE *Reverse Power Normal *Reverse Power Emergency * Optional Equipment 2.5 Dry Contacts form C : ES Engine Start One set of contacts to initiate Engine Start. SIE Switch In Emergency Two sets of contacts for remote annunciation. SIN Switch in Normal Two sets of contacts for remote annunciation. NOR *Normal Available Two sets of contacts for remote Normal Available indication. TRBL Trouble One set of contacts for remote annunciation. TDBT *Transfer Pre-signal Two sets of contacts for remote Transfer Pre-signal initiation. EMR *Emergency Available One/Two sets of contacts fro remote Emergency Available indication (number of customer contacts available depend on Options Accessories Selected). * Optional Equipment 2.6 Diagnostics The MP7650 has a full array of diagnostic features that allow the trained technician to understand the status of the transfer switch at all times. In addition to a series of encoded diagnostic routines internal to the firmware, the following additional diagnostic tools are available. 1. The Main Control Board is equipped with diagnostic LED s, which annunciate all 16 inputs and 14 outputs of the controller. 2. A dedicated trouble relay is provided to provide remote annunciation of improper operation of the transfer switch. 3. The display on the LCD of the various faults and conditions pinpoints the improper operation with crystal clear accuracy. The nine types of fault that will be displayed are: Ground Fault*, Reverse Power*, Bell Alarm (normal or emergency)*, Open Normal Failed, Open Emergency Failed, Both Opens Failed, Close Normal Failed, Close Emergency Failed. 4. Since the power supply to the MP7650 is separately derived from the normal and emergency sources, all diagnostic information is retained during a power outage. 2.7 Switches MD Maintenance Disconnect. This two position switch is mounted inside the enclosure and is provided so that the control circuitry can be de-energized for maintenance purposes. ORPB Override Pushbutton. This momentary switch is mounted inside the enclosure and is provided so that the TDR timer can be bypassed during testing. LTS Load Test Switch. This momentary switch is mounted inside the enclosure and is provided so that a complete load test can be initiated without use of the HIM Interface Panel. This switch when momentarily depressed will simulate a complete load test cycle (i.e. start the engine and transfer to emergency; and return to normal and stop the engine).

MSE Menu Switch Enable. This switch is mounted inside the enclosure and is provided so that the MHI Panel touch pads can be deactivated so that no unauthorized change in operating mode can be accomplished by non-authorized personnel. OPTIONAL ACCESSORIES 3.0 ACCESSORIES AVAILABLE MP7650 CONTROLLER ACBT Auxiliary Contacts Before Transfer - This option provides 2 sets of dry contacts which change state prior to transfer in either direction. Time delay between initiation of the contacts and switch transfer is field adjustable 0-300 seconds. ACSA Auxiliary Contacts Source Available - This option provides 2 sets of dry contacts for each source, which are energized whenever the sources become available. CBT Circuit Breaker Trips - This option provides over-current protection within the transfer switch on either or both sources. This feature may eliminate the requirement to install separate over-current protective devices on either the Normal or Emergency source or both. Trips are available as either thermal magnetic or Electronic depending on the switch. Includes source tripped pilot light. CTT Closed Transition Transfer - This options provides transfer of power from one source to another without interruption of power to the load. Includes a Synchronize Fail Timer to protect against extended paralleling with the Normal Source. This option is for use on Dual Motor and Insulated Case switches only. Consult factory for details. FPC Fire Pump Control - This option provides all necessary features required under NFPA 20 for Automatic Transfer Switches to be used with centrifugal fire pump controls. GFI Ground Fault Indication - When a ground fault is detected on the load bus of the transfer switch, the transfer switch will annunciate the condition but will not place the switch in the fault mode. Includes Ground Fault Pilot Light. GFP Ground Fault Protection - When a ground fault is detected on the load bus of the transfer switch, the transfer switch will disconnect both sources from the ground fault and operation will be placed in the Fault mode. Includes Ground Fault Pilot Light and Not In Auto Pilot Light. LDI Load Demand Inhibit - This option provides an input to the controller, which either will remove, the load from the emergency source, if connected, or will inhibit the transfer switch from being transferred to emergency. This option is used in conjunction with load demand control in associated Lake Shore Electric Paralleling Switchgear. MLT Maintained Load Test - This option provides a maintained load test switch in place of the standard momentary load test switch inside the transfer switch. It also includes a terminal block, which will accept a remote signal to force the switch to emergency. RN Return to Normal - This option provides immediate return to the Normal source when available. The TDR is not present therefore return to Normal when Emergency is available will not occur. This switch will, of course, return to Normal upon the loss of the Emergency source. PS Peak Shave - This option provides in input to the controller, which will cause the transfer of the load to the emergency source. This is typically used in conjunction with other energy saving systems. Returns to

normal should emergency source fail. MP7650 CONTROLLER RD Remote Disconnect - This option provides the ability to remotely disconnect both sources of the transfer switch from the load and operation will be placed in the fault mode. Includes Source Tripped Pilot Light. SE Service Entrance - Provides for transfer switch (Dual Motor & Insulated Case only) to be approved for use as service entrance equipment. Includes over-current protection, source tripped pilot light, selector switch, neutral bus bar, lugs, bonding jumper and other special items as required by NEC. SH Space Heater SPP Single Phase Protection - This option will open the Normal Source even when the Emergency source is not available to prevent damage to the load due to under voltage or single phasing. SPD Surge Suppression Device - This option provides a degree of protection for the transfer switch from voltage surges, which may damage control circuitry. Protection includes secondary surge suppressors on both power sources up to 40kA per phase.