Commander Pro 100 SUBMERSIBLE SYSTEM Installation, Operation and Trouble-Shooting Manual

Similar documents
OWNERS GUIDE TO INSTALLATION AND OPERATION OF 1/2-5 HP, 5, 7, 10, 15, 19 & 27 GPM 4 SUBMERSIBLE PUMPS

Centrifugal Constant Pressure Control

Centrifugal Constant Pressure Control

Commander Pro Variable Speed Controller System Instructions

Commander Pro Variable Speed Controller System Instructions

Pump Station. Models ADW2W31, ADW2W51, ADW2W71, ADW2W73

2 Wire Plus Ground 3 Wire Plus Ground IL0655

Potable Water Submersible Turbine Pumps

SHALLOW WELL JET PUMP

STAR STOP SHALLOW WELL JET PUMP

Constant Pressure - Variable Speed Drive Systems

PRE-PLUMBED SEWAGE SYSTEM

LAWN SPRINKLER, IRRIGATION PUMP

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

GARDEN HOSE UTILITY PUMP

AUTOMATIC SUBMERSIBLE UTILITY PUMP

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

4" SUBMERSIBLE PUMP. ST SERIES (stainless steel) FEATURES. OPTION Extended 5 years warranty plan offered by the manufacturer

END SUCTION CENTRIFUGAL PUMPS

SUBMERSIBLE SUMP PUMPS

SUBMERSIBLE SUMP PUMPS

Electronic Products ELECTRONIC MAINTENANCE

Installation & Operating Manual

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

END SUCTION CENTRIFUGAL PUMPS

STEP-BY-STEP INSTALLATION GUIDE

Installation Instructions and Parts Manual CPJ SERIES JET PUMPS. Shallow Well Jet Pumps. Convertible Jet Pumps. Ejectors (Purchase separately)

4" SUBMERSIBLE PUMP 4" SUBMERSIBLE PUMP. "GS" series. "ST" series. "SL" series. ST Series (stainless steel) SL Series (thermoplastic)

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

Professional Series 1/2HP 2 YEAR WARRANTY CONVERTIBLE JET PUMP REPAIR PARTS

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

Material required for drilled well application (indoor use only)

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Installation & Operating Manual

DRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131

MODEL SS INSTALLATION INSTRUCTIONS

HALLMARK INDUSTRIES INC. Deep Well Submersible Pumps Operating & Installation Instructions

SPECIFICATIONS: Tank Size: 80 gallons PUMP RPMs: 1050 CFM: 40PSI; 90 PSI Max Pressure: 150 PSI Thermal overload protection

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI

Model T Professional Series 1/2HP 2 YEAR WARRANTY SHALLOW WELL JET PUMP

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions

3-Wire Deep Well Submersible Pump

PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps

FHOTON Drive. Installation Guide

INSTALLATION INSTRUCTIONS

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

A B C D E F. Tools Required (supplied by others)

Installation and Operating Instructions

Installation, Operation and Maintenance Manual Stancor SE, SV, SS & SC Series Pumps

M-3025CB-AV Fuel Pump

Owner's/Installation Manual

HALLMARK INDUSTRIES INC

Series: PFSWCPC75. 3/4 HP 1750 RPM 60 Hz Submersible Sewage Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

SS/SSH Submersible Pump. Owner s Manual

A B C D E F. b.tools Required (supplied by others) 3/16" Drill Bit 3/8" Wrench Phillips Head Screwdriver

End Suction Centrifugal

INSTALLATION INSTRUCTIONS

HP Volts Stages Discharge Head Length Brand S10P4HS /2 6 S10P4HS / " Sta-Rite S10P4HS Stainless Steel

INSTALLATION INSTRUCTIONS MODELS S S SHALLOW WELL & CONVERTIBLE JET PUMPS PAGE 3 PAGE 8

2-Wire Deep Well Submersible Pump

PL Submersible, Semi-Vortex, Water Feature Pump

Model &

OWNERS GUIDE TO INSTALLATION AND OPERATION GPM and GPM GPM SUBMERSIBLE PUMPS

2015 EDITION SUBMERSIBLE MOTORS AIM MANUAL. APPLICATION INSTALLATION MAINTENANCE 60 Hz, Single-Phase and Three-Phase Motors. franklinwater.

Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

WARNING Carefully Read These Instructions Before Use

Installation Instructions CONSTANT WATT (CW) AND SELF-REGULATING (SR) PIPE TRACING CABLES

M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual

Installation and Operating Instructions

Installation & Operating Manual

PowerFLO 5800/5900 Series

Potable Water Convertible Jet Pumps

WORKHORSE. Assembly / Operation Instructions / Parts

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Installation & Operating Manual

TABLE OF CONTENTS. Pump Selection General Safety Electrical Installation Troubleshooting Repair Parts...

The POWER. In PRESENTATION PRODUCTS. Instruction Book for COSMOPOLITAN ELECTROL For Sizes Up To 9'x12' DA-LITE SCREEN COMPANY, INC.

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

The Da-Lite Difference.

ProFlo FatBoy

SUNC3000 / Item #40885

ESE Series Cast Iron Sewage Pumps

WORKHORSE. Assembly / Operation Instructions / Parts 15 GALLON TRAILER SPRAYER

BMK-18 U.S. Patent #5,298,158

WORKHORSE. Assembly / Operation Instructions / Parts 25 GALLON TRAILER SPRAYER

SubDrive75/100/150/300/2W MonoDrive, MonoDriveXT

Installation Instructions Light Commercial & Irrigation Water Pressure Booster System

CONSTANT PRESSURE CONTROLLERS

SUBMERSIBLE ELECTROPUMPS 50 HZ

SUBMERSIBLE TURBINE PUMPS OWNER'S MANUAL

Owners Manual: - Pumps

CONSTANT PRESSURE CONTROLLERS

M-1115S Series Fuel Pump

OWNER'S MANUAL SAVE THESE INSTRUCTIONS

OWNER S MANUAL Series: PFSPPPP33 1/3 HP 3450 RPM 60 Hz Series: PFSPCPC50 1/2 HP 3450 RPM 60 Hz Submersible Sump Pumps

SubDrive75/100/150/300/2W MonoDrive, MonoDriveXT

Transcription:

Commander Pro 100 SUBMERSIBLE SYSTEM Installation, Operation and Trouble-Shooting Manual FW1206 0608 Supersedes NEW Owner Information System Model Number Pump Model / Date Code Pump Serial Number (Silver Label) Motor Model / Date Code Motor Serial Number (Silver Label) Controller Model / Date Code Dealer Address Install Date Table of Contents Safety Instructions............................. 2 System Components........................... 3 Piping & General Information..................... 3 Pump Installation.............................. 4 Controller Location Selection..................... 5 Controller Installation / Wiring.................... 6 Start-up Operation............................. 6 System Troubleshooting......................... 7 Smart Reset Feature........................... 7 Toll Free Help Lines............................ 7 023050 1

IMPORTANT SAFETY INSTRUCTIONS RULES FOR SAFE INSTALLATION AND OPERATION 1. Read these warnings and instructions carefully. Failure to follow them could cause serious bodily injury and/or property damage. 2. Follow all local electrical and safety codes as well as the National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA). 3. The power supply should be a separate circuit, independent of all other circuits. Be sure it is equipped with a fuse and disconnect box of ample capacity. 4. For fire protection, the power supply should be free of any building, preferably on a direct line from the transformer. In the event of fire, the wires will not be destroyed and the water supply not cut-off. 5. Always disconnect power source before performing any work on or near the motor or its connected load. If the power disconnect point is out-ofsight, lock it in the open position and tag it to prevent unexpected application of power. Failure to do so could result in fatal electrical shock. 6. DO NOT handle pump with wet hands or when standing in water as fatal electrical shock could occur. Disconnect main power supply before handling pump for any reason. 7. Shut off power source when voltage drops below 210 on 230 volt installations. 8. Protect the power cable from coming in contact with sharp objects, oil, grease, hot surfaces or chemicals. DO NOT kink the power cable. If damaged replace immediately. 9. NEVER leave the control box, fused disconnect switch, or covers open (either partially or completely) when not being worked on by a competent electrician or repairman. 11.Install all electrical equipment in protected area to prevent mechanical damage which could produce serious electrical shock and/or equipment failure. 12.Pump is designed to pump cold ground water that is free of air or gases. Decreased pump performance and life expectancy can occur if the ground water is not cold (86ºF/30ºC) or contains air or gases. 13. Pump and controls must be securely and adequately grounded as specified in section 250-43 item (A) of the U.S.A. National Electric Code (NEC) and Section 26-954 Canadian Electrical Code. Failure to do so could result in a fatal injury. 14.DO NOT use this pump to pump flammable liquids such as gasoline, fuel oil, kerosene, etc. Failure to follow the above warning could result in property damage and/or personal injury. 15. The pump is intended for use in a well. Motor frame must be connected to power supply ground or fatal electrical shock may result. Do not use this pump in swimming pools. 16. This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. NOTE: Pumps with the CSA mark are tested to UL standard UL778 and certified to CSA standard C22.2 No. 108. 10. Always use caution when operating electrical controls in damp areas. If possible, avoid all contact with electrical equipment during thunderstorms or extreme damp conditions. 2

Section 1 System Components Please be sure that you have all major system components necessary to properly install the Commander Pro 100 Submersible pump system. Other components may also be necessary depending on the application requirements. 1. Submersible Pump End 2. Submersible Motor 3. CP Water Controller - SubDrive 100 4. Pressure Switch (packaged with controller) 5. Pressure Relief Valve (purchased separately) 6. Pressure Gauge (purchased separately) Section 2 Piping General Information The Commander Pro 100 system is capable of flows up to 40 GPM. Discharge piping is recommended to be 1.25 for installations in which flows will exceed 12 GPM. The use of smaller pipe will increase friction losses and can severely limit the maximum capacity of the system. This pump may be capable of pressures exceeding 325 PSI under maximum conditions, select pipe accordingly. Consult your pipe supplier to determine the best pipe material for the installation Pump Inspection Prior to installation check the pump, motor, controller and tank for shipment damage. Pressure Tank Use a minimum 4.5 gallon tank to ensure optimum pressure regulation. An existing, or larger tank can be used with this system, if desired. Pressure Setting Guide System Pressure (at Pressure Sensor) Pressure Tank Setting (PSI) (+/- 2 psi) 25 18 30 21 35 25 40 28 45 32 50 (factory set) 35 55 39 60 42 65 46 70 49 75 53 80 56 Pressure Relief Valve The pressure relief valve and the discharge outlet need a flow rating which exceeds the flow capacity of the installation at the relief pressure. When located in an area where a water leak or relief valve blow-off may damage property connect an adequate drain line to the pressure relief valve. Run the line to a suitable drain or to an area where the water will not damage property. Not providing an adequate relief valve can cause extreme overpressure which could result in personal and/or property damage. It is recommended that you manually activate the valve monthly to keep it in good working order. Discharge Pipe When discharge piping requires an adapter it is recommended that a stainless steel adapter be used. Galvanized fittings or pipe should not be connected directly to the stainless steel discharge head of the Commander Pro pump as galvanic corrosion may occur. Barb type connectors should always be double clamped. Torque arrestors are not required on this installation due to the soft starting characteristics of the Commander Pro 100 motor and controller Check Valve A check valve is factory installed in the discharge head of the Commander Pro 100 submersible pump. This maintains water within the pipe when the pump is not operating. For well depths exceeding 125 feet, an additional check valve should be installed every 125 feet. Safety Rope A safety rope eyelet is provided at the discharge of the pump. It is recommended to attach a nylon safety rope. This will assist in the removal of the pump and also prevent loss of the unit in the bottom of the well due to a loose fitting or pipe deterioration. Section 3 Pump Installation 1. The following installation instructions as shown use 160 PSI plastic pipe. Schedule 80 PVC pipe or galvanized pipe may also be used. If either of these two types are used, a foot clamp will be required to hold the PVC or galvanized pipe while connecting the next length of pipe. 2. Lay the pump a foot or two from the well, pointing outward (pump discharge away from the well). 3. Lay out plastic pipe, safety rope, hose clamps, piping, tape, submersible cable, etc. 4. Assembly of all components that go into the well should be made horizontally on the ground, and then lowered into the well. 5. Install a stainless steel pipe adapter in the pump discharge tapping, using teflon tape. Do not use pipe wrench on any part of pump except the cast discharge of the pump. 6. Unroll plastic pipe in a straight line away from the pump. Be sure working surface is smooth to avoid damage to the plastic pipe and electric cable. Cut off sealed end of plastic pipe with a hacksaw. 3

7. Position two hose clamps over end of the plastic pipe. Slide plastic pipe over the plastic pipe adapter all the way to the shoulder. Position the clamp tightening screws opposite each other and away from the motor lead wires to prevent insulation damage. Tighten the hose clamps and tape clamp tab ends to pipe with plastic tape. 8. Splice the electric cable to the pump leads. Heat shrink tubing and Sta-kon connectors are recommended. It is necessary that the splice be water tight. 9. Unroll the electric cable along side of the plastic pipe. Be sure not to damage wire insulation, and that all kinks are straightened out. 10. Cut the plastic pipe to proper length. 11. Slide cable guards over plastic pipe and submersible cable. One at 15 ft. above the pump and one every 25 ft. thereafter. Secure guards in position with retaining clamps or tape. 12. Attach assembly used to plastic pipe with two stainless steel hose clamps. Tighten clamps securely. Be sure to assemble the elbow on the pipe above the well seal. This will prevent dropping of the pump and piping into the well as you lower it. 90 Elbow Adapter LOWERING PUMP INTO THE WELL Never support the weight of pump and piping by the electric cable, as this weight will break the cable connections. 15. The pump is now ready to be lowered into the well. A helper will be needed to handle the other end of the assembly. With the plastic pipe and wire cable assembly over your shoulder, lift the pump, being very careful not to kink the plastic pipe. 16. Guide the pump and piping into the well. Protect the cable when lowering to prevent scraping or damage by the edge of the well casing. 17. The helper brings his end of the assembly forward as needed. Keep the pipe, cable, and rope free of grass or other foreign matter. Well Seal Coupling Adapter 13. Tape electric cable to pipe about every five feet. Use only 1-1/2 to 2 wraps of tape, so as to allow for some movement of the cable. Tape spliced connections to pipe to eliminate rubbing against well casing. Leave four to five feet of slack, at the upper end to allow for plastic pipe stretch. 14. Tie safety rope, through eyelet on top of pump. Tape end of rope to prevent unraveling. Tape safety rope to pipe every 20 feet. Do not leave any slack in rope. Tie securely on bottom side of well seal or pitless adapter and tape end of rope. 18. When the entire assembly is in the well, make sure well seal is seated. Tighten the four bolts in well seal evenly. Section 4 Controller Location Selection The CP WATER SD100 standard NEMA 1controller is intended for indoor use and for operation in ambient temperatures up to 125 F (50 C). For outdoor installations, a system with a NEMA 4 rated controller must be used. (Models with 7th and 8th characters of N4 ). To ensure maximum weather protection, the unit must be mounted vertically with the cover properly aligned and secured with all lid screws. The following recommendations will help in selection of the proper location of the CP WATER SD100 unit: 4

1. A tank tee is recommended for mounting the tank, pressure sensor, pressure gauge, and pressure relief valve at one junction. If a tank tee is not used, the pressure sensor should relocated within 6 ft. (1.8 meters) of the pressure tank to minimize pressure fluctuations. There should be no elbows between the tank and pressure sensor. 2. The unit should be mounted on a sturdy supporting structure such as a wall or supporting post - please account for the fact that the unit weighs approximately 17 lbs. for NEMA 1 models and 22.0 lbs. for NEMA 4 models. 3. The electronics inside the CP WATER SD100 are aircooled. As a result, there should be at least 6 inches of clearance on each side and below the unit to allow room for air flow. Due to the inherent voltage changing characteristics of variable frequency drives (VFD), there is additional stress placed on the insulation of the wire between the controller and the motor compared to a standard pump system. Extra care must be taken when using Unjacketed Flat Parallel Pump Cable to ensure that the insulation on each of the separated wires is the same thickness. Care must also be taken to ensure a proper seal with shrink tubing on any splices. Failure to take these precautions can lead to wire burn through that will shut down the system. Under these circumstances, no permanent damage usually occurs to the controller or motor. For further details call Technical Support at 1-800-742-5040. IL0837 SEPARATED WIRE There should be at least 6 inches of clearance on each side and below the unit to allow room for proper air flow. There are to be no elbows between the tank and pressure switch. 4. The CP WATER SD 100 should only be mounted with the wiring end oriented downward. The controller should not be placed in direct sunlight or other locations subject to extreme temperatures or humidity (mounting location should not be subjected to freezing conditions or condensation). 5. The mounting location should have access to 230V electrical supply and to the submersible motor wiring. WIRE SIZING Maximum wire lengths connecting the CP100 controller to the main circuit box. (Based on 3% voltage drop at 230V) Copper Wire Size (AWG) 12* 10 8 6 4 3 2 Maximum Length (Feet) 85 140 220 345 550 680 895 *Wire with 90 C insulation only. Maximum wire lengths connecting the motor to the CP100 controller Copper Wire Size (AWG) 14 12 10 8 6 Maximum Length (Feet) 320 510 810 1280 2010 1. NOTE: DO NOT USE ALUMINUM WIRE. 2. Use 20 Amp circuit breaker for 230V supply Controller Installation Procedure - SD100 1. Disconnect electrical power at the main breaker 2. Drain the system (if applicable) 3. Install pressure sensor - the pressure sensor has a 1/4-18 National Pipe Thread (NPT) connection. 4. Remove the CP WATER SD100 cover by removing the three lid screws. Install the unit to the wall using three mounting screws (not included). Wiring Connections 1. Verify that the power has been shut off at the main breaker. 2. Verify that the dedicated branch circuit for the CP WATER SD100 is equipped with a 20 AMP circuit breaker. 3. Remove the CP WATER SD100 lid. 4. Feed the motor leads through the opening on the bottom right side of the unit and connect them to the terminal block positions marked (green ground wire), Red (Black) Yellow (Brown) and Black (Blue) 5. Feed the 230V power leads through the larger opening on the bottom left side of the CP WATER SD100 controller and connect them to the terminals marked L1, GND, and L2. 6. Feed the pressure sensor leads through the smaller opening on the bottom left side of the CP WATER SD100 unit and connect the red and black leads to the terminals marked 1 and 2 (interchangeable) with a small screwdriver (provided). 7. Use the appropriate strain relief or conduit connectors. 5

8. Replace the cover. Do not over-tighten the screw. 9. Connect the other end of the pressure sensor cable with the two spade terminals to the pressure sensor. The connections are interchangeable. system, and if observed, should not be interpreted as a failure in the performance of the CP WATER SD100. Remove rubber end cap to adjust pressure. Use 7/32 allen wrench Pressure sensor boot IL0026 A 10 foot section of cable is provided with the CP WATER SD100 to connect to the pressure sensor. Lengths of up to 100 feet can be used, provided the appropriate shielded cabling is used. Consult the factory for proper cable specification. 10. Set the pressure tank pre-charge to 70% of the desired water pressure setting. To check the tank s pre-charge, de-pressurize the water system by opening a tap. Measure the tank pre-charge with a pressure gauge at its inflation valve and make the necessary adjustments. 11. The pressure sensor communicates the system pressure to the CP WATER SD100 controller. The sensor is preset at the factory to 50 psi, but can be adjusted by the installer using the following procedure: a. Remove the rubber end-cap. b. Using a 7/32 Allen wrench (provided), turn the adjusting screw clockwise to increase pressure and counter-clockwise to decrease pressure. The adjustment range is between 25 and 80 psi (1/4 turn = approximately 3 psi). c. Replace the rubber end cap. d. Reset the pressure tank pre-charge to the appropriate pressure 12. Cover the pressure sensor terminals with the rubber boot provided. Start-Up Operation Apply power to the controller. A steady green light indicates that the CP WATER SUBDRIVE 100 has power but the pump is not running. The green light will flash continuously when the pump is running. NOTE: Conventional private water systems intermittently fill a pressure tank as commanded by a standard pressure switch (e.g. 30-50 psi). The CP WATER SD100 maintains a constant pressure at the pressure sensor up to the maximum capability of the motor and pump. Although the pressure is constant at the pressure sensor, pressure drops may be noticeable in other areas of the home when additional taps are opened. This is due to limitations in the plumbing and will be more pronounced the further the taps are from the pressure sensor. This would be true of any 6

SYSTEM TROUBLESHOOTING Should an application or system problem occur, built-in diagnostics will protect the system. The red FAULT light on the front of the CP WATER SD100 controller will flash a given number of times to indicate the nature of the fault. In some cases, the system will shut itself off until corrective action has been taken. Fault codes and the recommended corrective action for each are listed in the following table. # of Flashes Fault Possible Cause Corrective Action 1 Motor underload Overpumped or dry well. Worn pump. Broken motor shaft. Blocked pump or screen Wait for well to recover and automatic restart timer to time out. If the problem does not correct, check motor and pump. See description of Smart Reset below troubleshooting chart. 2 Under voltage Low line voltage Check for loose connections. Check line voltage. Report low voltage to the power company. Unit will start automatically when the proper power is supplied. 3 Locked pump Motor/pump misaligned. Abrasives or sand bound pump Unit will attempt to free a locked pump. If unsuccessful, check the motor and pump. 4 NOT USED 5 Open circuit Loose connection. Defective motor or cable Check motor wiring. Make certain all connections are tight. Make certain proper motor is installed. Cycle input power* to reset. 6 Short circuit Defective cable, splice or motor Check motor wiring. *Cycle input power to reset. 7 Overheated controller High ambient temperature. Direct sunlight exposure. Obstructed air flow. This fault automatically resets when the temperature returns to a safe level. * Cycle input power means, turn the power off until both lights fade off and then apply power again. Description Part Number Pressure Switch 020627 100 Pressure Switch Cord 020628 Controller - Standard 023045 Controller - NEMA 4 023046 Motor 137462 Pump end for CP10007LT (N4LT) CP10007RP Pump end for CP10010LT (N4LT) CP10010RP Pump end for CP10019LT (N4LT) CP10019RP Pump end for CP10027LT (N4LT) CP10027RP Pump end for CP10035LT (N4LT) CP10035RP 7

TROUBLESHOOTING GUIDE Symptom Possible Cause Corrective Action Water flow rate is not as high as expected Motor is running backwards. Temperature in the controller is too high. If the controller s heat exchanger becomes too hot, the controller will reduce the speed of the pump to lower the power consumption. Pump capacity cannot supply the demand Switch two of the three wires leading from the controller to the motor (3-phase motor). Make sure there is at least 6 inches of room around the controller for movement of air. Use pump with higher flow rating (if head requirement is still satisfied). Excessive pressure fluctuations Waterlogged tank. Pressure tank is too small for flow rating of the pump. Check tank for bladder damage - replace if necessary. Reset the tank pre-charge pressure (should be 70% of pressure sensor setting). Use larger tank (4 gal tank minumum). Motor runs continuously with no flow demand from the house. Leak in the pitless adapter. Leak in the household or outdoor plumbing. Re-seat the pitless adapter Check for leaky faucets, valves and pipe fittings and repair. Smart Reset If a motor underload fault condition occurs, the most likely cause is an overpumped or dry well. To allow the well to recover, the CP WATER SD100 will wait 30 seconds to 5 minutes, determined by duration of the previous run time, before restarting the motor. For example the first time the fault occurs, the CP WATER SD100 will wait 30 seconds before attempting to restart the pump. If the system would then run for 1 minute and an underload fault reoccurs, the controller will wait 4 minutes before attempting to restart the pump. This schedule allows for the minimum off-time possible based on the recovery time of the well. TOLL FREE HELP LINES: Flint & Walling, Inc....................... 800-345-9422 Franklin Electric Service Hotline........... 800-348-2420 8 020324