www. ElectricalPartManuals. com It'll Cutler-Hammer WLI Medium Voltage Switchgear Renewal Parts Renewal Parts Data Page 1

Similar documents
WLI Medium Voltage Switchgear Renewal Parts

Description Notes. 1. Parts are identified by Breaker Type in the top row and Part Description in the left column.

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

Instruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035

Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana 47401

FOR PRICES ON DSII and DSLII BREAKERS, REFER TO PRICE LIST PL.22B.01.P.E

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

VacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components

A200 NEMA Contactors and Starters A200

Cable-Operated Disconnect Switches. Accessories

BUSSMANN. 8.3kV E-Rated SERIES. Medium voltage fuses for feeder circuit, switchgear and transformer. protection. Technical Data 10352

Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana Indoor-Outdoor Altitude 0-10,000 feet KV

Cutler-Hammer. Instructions for Potential Transformer and Auxiliary Control Power Disconnecting Means for Use in Ampgard Lineups, 7.2 kv I.B.

Medium Voltage Metal-Enclosed Switches

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

RBA Catalog Numbers and Information

S&C Mini-Rupter Switches Application The Standard Mounting Arrangement Scheme for S&C Mini-Rupter Switches Typical ED, reduced from full 11 size.

www. ElectricalPartManuals. com r" n;;-==- Westinghouse Ventilated Dry Type Transpac Power Centers Page 1 Descriptive Bulletin

Motor Control. Motor Control Electrical Aftermarket Products and Services Contents

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv)

16.13 Unit Substation to 15kV Construction Standards Page 1 of 7

www. ElectricalPartManuals. com Type AM Magne-Biast Circuit Breakers RENEWAL PARTS

Medium Voltage Metal-Enclosed Switches

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers

Outdoor Padmount Switching Products

www. ElectricalPartManuals. com GENERAL. ELECTRIC RENEWAL PARTS METAL-CLAD SWITCHGEAR TYPES M-26 AND M-36 GEF-4351C Supersedes GEF-4351B

TYPE PSI/II PADMOUNT SWITCHGEAR 15KV 25KV

MDS Dead-front Padmount Switchgear Style Guide 1VAM SG May 2010 Revision D

500 and 690 V a.c. am NH fuse links

Product Selection 3-Pole Contactors

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

www. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003

Cutler-Hammer. January 2001

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

Copper Double Break Switch

www. ElectricalPartManuals. com Instructions for Load Break Air Switch, Type LBF, for Power Centers

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak

PT Medium voltage fuses for potential and small power transformers

SERIES G100 / G110 SPECIFICATION 15KV & 25KV SUBMERSIBLE & VAULT MOUNTED SF 6 -INSULATED VACUUM LOAD INTERRUPTING SWITCHES

Specifications. S&C Alduti-Rupter Switches with Power Fuses Outdoor Distribution (14.4 kv through 46 kv)

SIEMENS. Series 8100oT Vacuum Controllers. www. ElectricalPartManuals. com. Bulletin CC

SIEMENS-ALLIS. Medium Voltage. Metalclad Switchgear. www. ElectricalPartManuals. com

1VAL2401-SG Rev D. Spare parts list for Outdoor Products Reclosers, breakers, & padmount switches

SWITCHGEAR DIVISION PRODUCT PROFILES

3.6. Current Limiting Fuses. Contents. ACLS, BCLS, CLS, HCLS and NCLS Type Fuses. ACLS, BCLS, CLS, HCLS and NCLS Type Fuses

Copper Vertical Break Switch kv A.

INDEX Welcome 1.2 Contacting Powergrid Solutions, Inc. 1.3 Terms Of Usage 1.4 Product Codes and Descriptions

Aluminum Vertical Break Switch kv A.

www. ElectricalPartManuals. com

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

DS/DSII Low Voltage Switchgear. Renewal Parts. Cutler-Hammer. Renewal Parts. Effective: October Page 1

www. ElectricalPartManuals. com RENEWAL PARTS DATA Westinghouse Electric Corporation WESTINGHOUSE EQUIPMENT FOR FURNISHED TO

Contactors & Fuses. Power Breakers, Power Breakers, Contactors & Fuses Contents

www. ElectricalPartManuals. com INSTRUCTIONS "INERTEEN AND OIL INSULATED FEEDER SWITCHES DESCRIPTION INSTALLATION MAINTENANCE

Product Specifications for Phase Over Phase GOABS(r)

Each of these factors, as they apply to the selection of Types CLE and CLS current limiting fuses, is briefly outlined on the following pages.

www. ElectricalPartManuals. com CPL Station Arrester Controlled Protective Level Page 1 Indoor-Outdoor Altitude 0-10,000 feet KV

Specifications. S&C Power Fuses Types SM and SMLa. For use with SM Refill Units or SMU Fuse Units. Indoor Distribution (4.16 kv through 34.

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

Westinghouse Breaker Maintenance Manual READ ONLINE

Frame Sizes: AKJ/ AKJT I AKJU-50 and AKR/ AKRU-30/ 50, AKRT-50

Instructions for A200, A210, A250 size 6, two- or three-pole non-reversing or reversing motor controllers

www. ElectricalPartManuals. com BBC Brown Boveri Electric Renewal Parts 1-T -E Low-Voltage Power Circuit Breakers

2.7. Expulsion Fuses. Contents. RBA/RDB Type Fuses (Including Superseded BA Fuses) RBA/RDB Type Fuses (Including Superseded BA Fuses)

Type ICX Interchangeable Cutout kv Outdoor Distribution Cutout Product Bulletin 1VAG DB

Effective December 2015 Supersedes September 2013

CLEAVELAND / PRICE INC. Type RL-C Side Break Switch kv A. Bulletin DB-104E12

Horizontal Circuit Switchers

Horizontal Circuit Switchers

15-kV Live Terminal 600 Amp Group Operated Pad-Mounted Metal-Enclosed Outdoor Switchgear 140 Amp (Max) Clip Mount Current-Limiting Fuses

5H KA, RMS C/L Recommendations for Stock POLE UNIT PARTS ARC CHUTE DETAILS. Core, Fig. 17, It.

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch

Westinghouse Electric Corporation Distribution and Control Business Unit Electrical Components Division Pittsburgh, Pennsylvania, U.S.A.

FP AUTOMATIC METAL-ENCLOSED SWITCHGEAR

Product Specifications for Aluminum Vertical Break Switches

SERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

RENEWAL PARTS I C302AA A-2 300V AB A-4800V A C A -SOOOV PARTS RECOMMENDED FOR NORMAL STOCK

VOYTEN ELECTRIC & ELECTRONICS

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

BBC. Renewal Parts. I-T-E Low-Voltage Power Circuit Breakers

STANDARD SPECIFICATION FOR TYPE PLD LIVE-FRONT/DEAD-FRONT PAD-MOUNTED SWITCHGEAR 15kV 25kV A. General

Aluminum Vertical Break Switch 345 kv, 1300 kv BIL 2000 A A.

LKN A 250V Super-Lag Fuse Link. Features amperage rating 200 class Voltage Rating 250. Long Description. Manufacturer Information

Westinghouse Molded Case Circuit Breakers Engine Generator FG Amperes

www. ElectricalPartManuals. com

www. ElectricalPartManuals. com Cutler-Hammer Power Breaker Center Renewal Parts for Low Voltage Power Circuit Breakers Types DB, DBL and DBF

Features, Benefits and Functions

Type ICX Outdoor open type cutout

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

DO-III Fuse Holder TPL , May 2000, Page 1 of 4. General Information on the DO-III Draw Out Load Break Expulsion Fuse Holder. ABB Inc.

500 Volts gg/gl NH Fuse links

SPECIFICATION BULLETIN

XL Photovoltaic fuse links

3.5. Current Limiting Fuses. Contents. CLPT and NCLPT Type Fuses. CLPT and NCLPT Type Fuses

HelioProtection HP10NH Photovoltaic fuse-links gpv 1000VDC

WARNING. TYPE PSI/II PAD-MOUNT SWITCHGEAR with Non-Loadbreak Fuse Mountings 15kV 25kV INSTRUCTIONS. Qualified Persons. For Installation and Operation

C E R T I F I C A T E O F C O M P L I A N C E

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

Instrument Transformer Reference. Meter and Relay Applications for the Electrical Industry

Transcription:

t'll Cutler-Hammer Supersedes Renewal Parts Data, pages 1-2, dated June 1992 Renewal Parts Data Page 1 WL Medium Voltage Switchgear Renewal Parts

Renewal Parts Data Page 2 WL Medium Voltage Switchgear Renewal Parts Standard Manually Operated Fused WL Switch Replacement Capabilities List G) Switch Pole Assembly Arcing Contact Assembly @ Drive Rod Link (Polyester) @ Drive Rod Link (Porcelain) (Not Shown) @ Switch Barrier Assembly @ Fuse Barrier Assembly @ Open Close ndicator/nterlock Cam @ Fuse Live Parts Kit

WL Medium Voltage Switchgear Renewal Parts Replacement Capabilities CD Switch Pole Assemblies @ Arcing Contact Assemblies 7 ' ; f" "'" @ Drive Rod Link (Polyester).5':l @) Drive Rod Link (Porcelain) nsulators Polyester J f Porcelain Part Description Switch Pole Assemblies Three-pole set includes main and flicker blades, break jaws, arc chutes and adjustment tool kit. (60 kv BL or 95 kv BL) 5 and 15 kv- 600 amperes 5 and 15 kv- 1200 amperes (110 kv BL) 15 kv- 600 amperes 15 kv- 1200 amperes (125 kv BL or 150 kv Bill 25 and 38 kv- 600 amperes ' Arcing Contact Assemblies Three-pole set includes flicker blades and arc chutes. This kit is not required when switch pole assemblies above are ordered. (60 kv BL or 95 kv BL) 5and 15 kv- 600 ampe s 5 and 15 kv- 1200 amperes (125 kv BL or 150 kv BL) 25 and 38 kv- 600 amperes Drive Rod Link (polyester, set of three) 5 kv (60 kv Bill 15 kv (95 kv Bill 15 kv (110 kv Bill 25 and 38 kv (125 kv BL or 150 kv Bill Drive Rod Link (porcelain) (set of three) 5 kv (60 kv-bil) 15 kv (95 kv-bil) 25 and 38 kv (125 kv-bl or 150 kv-bu nsulators (one each) (60 kv-bl) 5 kv Glass Polyester 5 kv Porcelain (95 kv-bl) 15 kv Glass Polyester 15 kv Porcelain (110 kv-bu 15 kv Porcelain ( 125 kv-bl or 150 kv-bl) 25 and 38 kv Porcelain Style Number 7278A27G01 7278A27G02 7278A27G03 7278A27G04 1 7278A27G05 7278A27G06 7278A27G07 7278A27G08 7278A27G09.7278A27G10 7278A27G11 7278A27G12 7278A27G13 7278A27G14 7278A27G15 4892A97H03 548D224G07 i 4892A97H04 548D235G07 548D236G07 1707C41G01 Renewal Parts Data Quantity per Switch Page 3 List Price Each $10130 13220 10520 13600 14400 2540 3320 3600 550 590 650 4350 5350 6350 100 440 100 500 540 1080 l'!t" N

Renewal Parts Data Page 4 WL Medium Voltage Switchgear Renewal Parts Replacement Capabilities, Continued Removable Handle Cll Switch Spring Mounting Assembly _:.=---..,._ -------=== --- = :;:! if> Open Close ndicator/nterlock Cam Auxiliary Switch Assembly Part Description Removable Handle All Ratings Switch Spring Mounting Assembly 5-15 kv- 40 ka Fault Close 5 kv- 61 ka Fault Close 15 kv- 61 ka Fault Close 25 kv- 20 ka Fault Close 25 kv- 40 ka Fault Close 25 kv- 60 ka Fault Close 38 kv- 20 ka Fault Close 38 kv- 30 ka Fault Close Switch Barrier Assembly 5and15 kv 25 and 38 kv Fuse Barrier Assembly 15 kv 25 and 38 kv Open-Close ndicator/nterlock Cam for Lock open/close or Lock open only Open-Close ndicator/nterlock Cam for Lock close only Auxiliary Switch Assembly (5 NO and 5 NC Contacts) Style Number 7274A49H01 7278A27G16 7278A27G17 7278A27G18. 7278A27G19. 7278A27G20 7278A27G21 7278A27G22 7278A27G23 7278A27G24 7278A27G25 7278A27G26 7278A27G27 220C934H01 220C934H02 7278A27G28 Quantity per Switch $ 90 1000 1500 1500 1050 1500 1540 3200 1540 3200 250 250 770

WL Medium Voltage Switchgear Renewal Parts Replacement Capabilities, Continued @ Switch Adjustment Tool Kit @ Fuse Live Part Kit._j @ Space Heaters Other Replacement Parts Other replacement parts are available but must be considered on a job-by-job basis. nclude switch nameplate information located behind the switch operating handle access door with any correspondence. Be sure this includes the "C N " or "SM" number. Part Description Switch Adjustment Tool Kit All Ratings Fuse Live Part Kit j Non Disconnect (Three-Phase- Top and Bottom) RBA200 5-15 kv RBA400 5-15 kv RBA200 25-38 kv RBA400 25-38 kv ClE-1 5-15 kv ClE-2 5-15 kv ClE-3 5-15 kv ex 5-15 kv CX N-1 5-15 kv (Single Barrel- 3 inch Dia.) CX N-1 5-15 kv (Single Barrel- 4 inch Dia.) CX N-2 5-15 kv (Double Barrel- 3 inch Dia.) CX N-2 5-15 kv (Double Barrel- 4 inch Dia.) NX 25 kv EJO 38 kv Space Heaters (Voltage shown is half Rated Voltage) 125 v 250 V Further nformation Literature Number DB ll 31-930-C Description Descriptive Bulletin for Wll load nterrupter Metal Enclosed Switchgear [ nstruction leaflet for Wll. and WVB Metal Enclosed Switchgear j Style Number 221C113G01 7278A27G29 7278A27G30 7278A27G31 7278A27G32. 7278A27G33 7278A27G34 7278A27G35 7278A27G36 7278A27G37 7278A27G38 7278A27G39 7278A27G40 7278A27G41 7278A27G42 220C974G03 220C974G04 Pricing nformation literature Number V STA/V STAL NE Renewal Parts Data Quantity per Switch ] Description Discount Symbol Y2 Page 5 List Price Each $ 925 1050 1125 925 1050 775 1175 1175 850 1190 275 275

Renewal Parts Data Page 6 WL Medium Voltage Switchgear Renewal Parts Cutler-Hammer Westinghouse & Cutler-Hammer Products 11 Corporate Circle Sumter, South Carolina, U.S.A. 29154 Printed in U.S.A.