Vacuum Circuit Breaker VS1

Similar documents
Medium voltage vacuum circuit breaker. E-VAC series

E-VAC EP Series Medium Voltage Vacuum Circuit Breaker

E-VAC EP Series Medium Voltage Vacuum Circuit Breaker

E-VAC Series Medium Voltage Vacuum Circuit Breaker

Powering business worldwide

24kV ET1 Removable AC Metal-enclosed Switchgear With VE24 Encapsulated Pole Vacuum Circuit Breaker

12kV W-VACi Series Medium Voltage Vacuum Circuit Breaker

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

40.5kV W-VACi Series Medium Voltage Vacuum Circuit Breaker

W-SLC Medium Voltage fused contactor truck A safe, reliable and efficient motor starter

The vacuum circuit breaker for commercial buildings, industrial plants and utilities

GAE CLAD. Catalogue Metal - Clad Switchgear Up To 24 kv. Vacuum Circuit Breaker With Embedded Poles. PT Guna Era Manufaktura

40.5kV ET2 Removable AC Metal-enclosed Switchgear

E6X MCB series. More complete More value

XIRIA Green, Smart, Compact solution

Experience, innovation and reliability

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

Vacuum Circuit Breaker

Metal Clad Air Insulated Switchgear

W-VACi MV circuit breakers

Outdoor vacuum breaker for railway applications - FSK II

WOLUN. ZN63A-12 (VS1) Type. ZN63A-12 (VS1) Type Indoor High Voltage Vacuum Circuit Breaker. General Introduction. Technical Specification

IEC medium voltage vacuum circuit breakers 12 kv, 17.5 kv and 24 kv Product Guide. W-VACi. for safety, reliability and performance

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

W-VACi IEC medium voltage vacuum circuit breakers 12 kv, 17,5 kv and 24 kv

SafeGear TM Motor Control Center Arc resistant metal-clad construction

Dead Tank Circuit Breakers

12kV xdl Removable AC Metal-enclosed Switchgear

Unitole UP kv Primary substations Motor control centres

CPG.0 Single busbar gas-insulated cubicles

Eaton Safe, Reliable, Efficient IEC MV Switchgear. xgear Safe, Reliable, Efficient IEC MV Switchgear

Removable AC Metal-enclosed Switchgear

Eaton Safe, Reliable, Efficient IEC MV Switchgear. xgear Safe, Reliable, Efficient IEC MV Switchgear

Solid Dielectric, Three Phase Reclosers CATALOG VS11

SL Series IEC Vacuum Contactors. Medium Voltage Contactors Technical Focus

the safe, reliable, and efficient choice for MV switchgear

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc

HVX Series. 36 kv Medium Voltage Vacuum circuit breaker. Make the most of your energy SM. Medium Voltage Distribution Catalogue 2015

Electrical sector solutions E Line family. Industry leading design in a compact package

Low & Medium Voltage Vacuum Contactors

VCP-T/T-VAC medium voltage vacuum circuit breakers. Control and protect with Eaton s compact medium voltage circuit breakers

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)

PIX-H Metal-clad switchgear up to 17.5kV

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

SF6 Load Break Switch 2017 FIL3 - S. Indoor Medium Voltage LBS With or without fuse 12kV- 24kV FIL3 D FIL3. 24KV SF6 Load Break Switch

Medium Voltage Metal-Enclosed Switches

KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS

Air-insulated switchgear UniGear type ZS1

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

NIRAPOD 5. Vacuum Circuit Breaker. 630A A: 7.2kV - 12kV 20kA - 25kA kA 12AV20. current CHARGED CHARGED

Benefits, typical uses

Vacuum Circuit-Breaker Modules

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Instruction for Installation and Operation

NXPLUS C Single busbar. Maintenance-free for lifetime

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

Unitole UP kv Primary substations Motor control centres

Air Insulated Switchgear NXAirS, 40.5kV Answers for infrastructure and cities.

GE Electrical Distribution. Gerapid High Speed DC Circuit Breakers. On the move. imagination at work

8DJ. Maintenance-free for lifetime

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

KYN28-12(GZSI-12Z)Armoured Middle-Mounted Metal. Enclosed Switch. 1.General. 2.Model Definition

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Switchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.

Contactor V-Contact VSC/P

THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com

Fixed-Mounted Circuit-Breaker Switchgear Type 8DA and 8DB up to 40.5 kv, Gas-Insulated

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

36kV Gas Insulated Medium Voltage Switchgear

Medium Voltage Metal-Enclosed Switches

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications

Certified for best-in-class performance, reliability, and safety. Trihal sets a new standard for dry-type cast resin transformers

Electrical sector solutions E Line family. Industry leading design in a compact package

Thermal Overcurrent Circuit Breaker 3120-F...

Innovac SVS/08 - SVS/ kv modular switchgear

Thermal Overcurrent Circuit Breaker 3120-F...

MINIATURE CIRCUIT BREAKER

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT

Thermal Overcurrent Circuit Breaker 3120-F...

CP Automatic capacitor bank

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

Gas Insulated Switchgear

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

Series KTU7 UL489 Molded Case Circuit Breakers

Medium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear. ABB Group February 25, 2015 Slide 1

Live Tank Circuit Breakers kV Reliability through Technical Excellence

MEDIUM VOLTAGE SWITCHGEAR

NDM3 Series. Molded Case Circuit Breaker. Shanghai Liangxin Electrical CO., LTD.

Xiria the smart solution

Thermal Overcurrent Circuit Breaker 3120-F...

EMC 24 SERIES METAL CLAD SWITCHGEAR. We engineer, we assure. Up to 24 kv - 25 ka With Withdrawable, Air-Insulated, Medium Voltage Distribution Panel

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Transcription:

Vacuum Circuit Breaker VS1

Product features Conform to GB, IEC, DL and JB standards KEMA type test Level A certificate Ideal contact material and shape, ensuring low current carrying value and stable contact resistance Integrated design of main conductive circuit made of compound isolation material and operating mechanism Few components and parts, compact and logical structure, assuring more reliable and safer operation Switching resistive, inductive and capacitive loads in an ideal way Compact design enables the breaker to be installed within almost all switchgears More than 100,000 sets of breakers used in operation Superior cost performance, ideal choice for engineering programs VS1 offers versatile applications Epoxy resin insulation cylinder manufactured with APG process can withstand severe environmental impacts, enabling VS1 breakers to be used in all kinds of situations. The utilization of special contact material and primary tulip contact ensures VS1 devices applicable for all medium voltage cases. 1 Chemical industry Substation, transformer substation Petroleum industry Cement industry Pipeline industry Automotive industry Offshore mining Metallurgical industry Shipbuilding industry Textile and food industries Paper industry Power plant Opencast coal mine Product application conditions Ambient air temperature is not exceeding ºC, and the average temperature measured within 24 hours is not exceeding 35ºC The minimum ambient air temperature is -15ºC Negligible effect by solar radiation Altitude is not exceeding 1000m Ambient air is not obviously polluted by dust, smoke, corrosive and flammable gases, vapor or salt mist Negligible vibration or quake external to the switchgear and controlgrear Amplitude of electromagnetism interference sensed in secondary system is not exceeding 1.61kV Average daily relative humidity: 95%; average monthly relative humidity: 90% Average daily vapor pressure: 2.2*10-3 MPa, Average monthly vapor pressure: 1.8*10-3 MPa No water dropping, flammable and explosive hazards in the application places, without chemical corrosive gases and violent vibrations. VS1 completely meets demands of power users VS1 series vacuum circuit breaker offers drawout type VS1 and fixed type VS1, based on different operation environments, applied separately for centrally installed switchgears and fixed type switchgears, to satisfy different requirements from users for different application occasions Drawout type VS1 breakers have been widely used in all kinds of centrally installed switchgears. Due to its reliable interlocking and stable performance, it can be applied within most of centrally installed switchgears. In the places where old generation switchgears are used, Eaton s fixed type VS1 breaker can still achieve mechanical interlocking* function with dedicated mechanical interlocking mechanism to coordinate with the old generation switchgear. VS1 series vacuum circuit breaker also offers solutions of all rated currents, to fully meet demands of electrical users. * Customers are required to provide relevant switchgear information for customization. Product model VCB model Rated voltage kv VS1-12 3150-50 Rated current A Rated short circuit breaking current ka

Technology creates history Eaton has over 80years manufacture experience of circuit breakers. Over the past 80years, we are leading global circuit breaker market with the most advanced technology and concept. In the world advocating environment conservation, the expectation for medium voltage power switching is very high. Along with lower impedance system configuration, the demand for current continuity and breaking capacity is higher; meanwhile the demand for installation in limited spaces and cooling is more stringent. The optimal solution is our medium voltage circuit breakers with advantages of pro-environment, reliably breaking heavy-duty current, without extra cooling or forced air cooling. VS1 vacuum circuit breaker requires almost no relevant maitenance Simple structure design of Eaton s VS1 vacuum circuit breaker minimizes fault occurrence, and simplifies daily maintenance. First class vacuum interrupters are utilized for the breaker, with reasonable price but superior performance Adoption of multi-point compressing contact method, lowering contact resistance and extending breaker s service life and without maintenance The insulation tension pole used for the breaker must be subject to force measurement, ensuring contact pressure in closing state, and can be traceable Optional accessory Charging handle Cradle handle Cradle Transport trolley 2

VS1 Construction Front View 1. Motor cutoff switch 2. Charging shaft 7 3. 4. Charging holding latch Charging spring 8 9 10 1 2 5. 6. 7. 8. Manual charging worm drive gear Motor output shaft Secondary plug Charging indicator 11 12 13 14 3 4 5 6 9. 10. 11. 12. 13. 14. Openingclosing indicator Auxiliary switch Opening coil Closing coil Oil dash pot Charging motor Side View Rear View 1 2 3 4 5 1. Lifting hole 2. Insulation pole unit 3. Primary disconnect 4. Vacuum interrupter 5. Insulation rod 3

Main specifications and technical parameters (VS1 drawout typefixed type) No. Item Unit Parameters 1 2 3 4 Rated voltage Rated power frequency withstand voltage (1min) Rated lightning impulse withstand voltage (peak) Rated frequency kv kv kv Hz 12 4248 7585 50 5 Rated current A 631250160020002500315000* 6 Rated short circuit breaking current ka 20 25 31.5 50 7 Rated short time withstand current ka 20 25 31.5 50 8 Rated short circuit making current (peak) ka 50 63 80 100 125 9 Rated peak withstand current ka 50 63 80 100 125 10 Rated short circuit duration s 4 11 Secondary circuit power frequency withstand voltage (1min) kv 2 12 13 Rated singleback-to-back capacitor bank breaking current ** Times of breaking 100% fault-current A Times 6300(8000-kA**) 50 (30 times at ka, 20 times at 50kA) 14 15 Closing time Opening time ms ms 35-70 20-50 16 Mechanical endurance Times 20000 10000 (50kA) 17 Rated openingclosing operation voltage V AC 110220 DC 110220 18 Rated voltage of charging motor V AC 110220 DC 110220 19 20 21 Closing bouncing time Opening asynchronism Closing asynchronism ms ms ms 2 2 2 22 Rated operating sequence O-0.3s-CO-180s-CO O-180s-CO-180s-CO (50kA) * 00A needs forced air cooling; ** Data are offered only on request by users 4

Outline dimensions (VS1 drawout type) V Travel 8-11 5

6 VS1 Vacuum Circuit Breaker Rated parameter P 630A 20~31.5kA 1250A 20~31.5kA 210 210 1250A ka 1600A 210 210 31.5~kA 1600A 50kA 2000A 31.5~50kA 2500-3150A 31.5~50kA 3150-00A H 310 310 310 310 310 K 295 295 295 295 295 L 586 586 586 586 586 B 652 652 652 652 C 361 361 361 361 361 D 698 698 698 698 698 E 77 77 77 77 77 F 88 88 88 88 88 G 6 6 6 6 M 277 277 277 277 Q 650 650 650 650 S 536 536 536 536 536 T 0 0 0 0 0 W 638 638 638 638 Z Ø35 Ø35 Ø49 Ø49 Ø49 Ø49 Ø55 Ø79 Ø55 Ø79 Ø79 Ø109 Ø109 V 34 34 34 34 34 ~50kA Note: unit (mm)

Outline dimensions (VS1 fixed type) P P G1 4 J 445 H DISCHARGE G2 E A(Position l) B(Position ll) C (Position l) F I L K 4-M12 (Position ll) Direction G1G2 80 Direction G1 Direction G2 15 4-M10 60 4-M10 50 80 50 2-M10 10 110 60 70 M18 Distribution panel width Rated current (A) P H A B C E F G1G2 I J K L 800 800 1000 1000 630~1250 1600 630~1600 1600~00 210 210 310 520 520 720 650 520 520 720 720 588 588 770 770 580 580 580 632 90 65 65 I I I II 250 7 7 7 252 455 455 455 465 410 410 430 430 * When ordering fixed type VS1,it is required to provide relevant technical requirements such as fixed panel type, the functions that mechanical interlock should achieve, assembly position and interface dimension of the circuit breaker and the mechanical interlock. Eaton Electrical Equipment will customize the device as per your request. 7

Control wiring diagram (VS1 drawout type) Motor circuit Closing circuit Latching circuit Opening circuit Connection settings of optional parts Jumper JP1 Configuration Jumper status Overcurrent trip (Phase B) Overcurrent trip (Phase C) JP9 JP8 JP7 JP6 JP5 Overcurrent trip (Phase A) JP4 JP3 JP2 With latch Without latch With latch Without latch With anti-pumping Without anti-pumping Auxiliary switch (to switch when VS1 is in working position) Auxiliary switch (to switch when VS1 is in testing position) Auxiliary switch Auxiliary switch (to switch after closing spring is charged) Auxiliary switch (to switch during openingclosing operations) Bridge rectifier (to cancel at DC) Latch coil (optional) anti-pupming relay (optional) Indirect overcurrent release coil (optional) Jumper S9: S8: S2: S1: QF: V2-V4: Y1: K0: Y7-Y9: JP1-JP11: Operating power supply options Jumper Operating power supply JP11 JP10 ACDC 220V ACDC 110V Notes: denotes disconnected; denotes connected. Closing coil Opening coil Resistance Charging motor HQ: TQ: R0-R1: M: Note: When in DC supply operations, the polarity within the dotted box shall be the same VS1 is in testing position, opening and uncharged state. 8

Control wiring diagram (VS1 fixed type) Motor circuit Closing circuit Latching circuit Opening circuit 26 24 2 5 4 20 31 3 5 7 9 8 28 46 11 1 V 2 V4 V3 M HQ K0 TQ S2 Y1 R1 JP 8 R0 JP 11 JP 1 0 (53) JP 9 (54) QF (51) (33) (73) (11) 3 1 41 71 6 1 63 3 3 83 43 21 (52) (34) Q F S1 ( 1 2 ) QF QF 3 2 42 72 6 2 64 24 3 4 84 44 22 (74) QF (5) (2) K0 (3) ( 11) (13) (21) mechanical latching S3 (12) (14) S1 S1 (22) S 1 3 6 34 35 14 10 30 41 13 15 17 19 18 33 38 12 22 21 Overcurrent trip (Phase A) Overcurrent trip (Phase C) Overcurrent trip (Phase B) 2 2 7 4 4 Y7 Y8 Y9 Connection settings of optional parts Configuration Jumper status With anti-pumping Without anti-pumping Operational power supply ACDC 220V ACDC 110V With latch Without latch With latch Without latch Operating power supply options Jumper JP10 JP11 Jumper JP8 JP9 HQ: TQ: M: S2: S1: S3: QF: K0: R0-R2: Y7-Y9: Y1: V2-V4: JP8-JP11: Closing coil Opening coil Charging motor Auxiliary switch Auxiliary switch (to switch after the closing spring is charged) Auxiliary switch (to switch after mechanical lock is in place, to cancel when no mechanical interlock is supplied Auxiliary switch (to switch during openingclosing operations) anti-pumping (optional) Resistance Indirect overcurrent release coil (optional) Latching coil (optional) Bridge rectifier (to cancel at DC) Jumper 3 7 42 4 3 Notes: denotes disconnected; denotes connected. Note: 1. When in DC supply operations, the polarity within the dotted box shall be the same 2. During installation and commissioning of mechanical interlock, make sure that S3 can be reliably switched after the mechanical interlock is in place 3. VS1 is in opening and uncharged state. 9

Ordering information Project name: Ordering quantity: Applications VS1 draw out type VS1 fixed type Primary data Rated voltage Rated current Rated short circuit breaking current 12kV 630A 20kA kv 1250A 25kA 1600A 31.5kA 2000A ka 2500A 3150A 00A* 50kA *00A needs forced air cooling Secondary configuration Power supply of charging motor DC 110V DC 220V AC 110V AC 220V Closing release DC 110V DC 220V AC 110V AC 220V Opening relaease DC 110V DC 220V AC 110V AC 220V Auxiliary switch 5NO+5NC Secondary wiring 58-pin plugsocket 46-pin plugsocket Optional configuration Overcurrent release Closing latch Position latch anti-pumping relay Undervoltage release 2 overcurrent 3 overcurrent A V V V V Options Cradle Contact arm (including contact finger, and contact arm cylinder) shutter-propelling bracket Blanking board cover plate Transport trolley Charging handle Cradle handle Contact information Company name: Department: Name: Phone: Fax: * For any questions, please contact Eaton Electrical Equipment Co., Ltd. 10

The power of fusion. 1833 1874 1886 1893 1897 1899 1906 1908 1911 191 4 1934 1961 1962 1963 1967 1977 1983 1984 1989 There s a certain energy at Eaton. It s the power of uniting some of the world s most respected names to build a brand you can trust to meet your every power management need. Eaton is dedicated to ensuring that reliable, effi cient and safe power is available when it s needed most. Building on over 100 years of experience in electrical power management, the experts at Eaton deliver customized, integrated solutions to solve your most critical challenges. To learn more visit www.eaton.comelectrical. All of the above are trademarks of Eaton or its affiliates. Eaton has a licenseto use the Westinghouse brand name in Asia Pacific. 2013 Eaton.

Eaton is a power management company with 2013 sales of $22.0 billion. Eaton provides energy-efficient solutions that help our customers effectively manage electrical, hydraulic and mechanical power more efficiently, safely and sustainably. Eaton has approximately 102,000 employees and sells products to customers in more than 175 countries. For more information, visit www.eaton.com.cnelectrical. Eaton Electrical Asia Pacific Headquarter No.3, Lane, Linhong Road, Changning District, Shanghai 200335 Tel: 021-52000099 Fax:021-52000200 Eaton Electrical Group Explanations and changes to the information contained in this document are reserved, without further notice VS1-EN (03-2014)