ORIMAS Mass Flowmeter

Similar documents
STEEMCO-MAS Flowmeter for Steam

STEEMCO Flowmeter for Steam

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

Model CO Compact Orifice for use with Foxboro Differential Pressure Transmitters

MWD. Industrial Temperature Assemblies RTD. Meassuring range ºC. Pt100 sensor class A, class B, class 1/3, class 1/10, or Cryogenic.

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

SATRON VDt Differential Pressure Transmitter

JUMO flowtrans DP R. Meter run R01 and orifice plate R02. Applications. Brief description. Special features. Customer benefits.

Metal tube variable area flowmeter for gases, liquids and steam

EMCO Primary Elements for Flow Measurement

Rosemount DP Flowmeters and Primary Elements

VersaFlow Vortex 100 Vortex Flow Meter Specifications

Orifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

SATRON VT Pressure Transmitter

VLM20 In-line Vortex Flowmeter

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

VersaFlow Vortex 100 Vortex Flow Meter Specifications

OPTIMASS 2000 Technical Datasheet

Multivariable Vortex Flow Meter

PanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits

Flow Measurement SITRANS F C. Flow sensor MASS 2100 DI 3 to DI 40. 4/180 Siemens FI

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Multivariable Vortex Flow Meter

VIM20 Vortex Insertion Flowmeter

OPTIMASS 3000 Technical Datasheet

Resistance thermometer For sanitary applications Model TR22-B, for orbital welding

OPTISWIRL 4070 Technical Datasheet

F-2500 SERIES VORTEX METER

CONSTRUCTION AND DESIGN OF INSTRUMENTS FOR FLOW, LEVEL AND TEMPERATURE. EMCO Liquid Level Switch

TRANSMITTER ATTACHES TO THIS SURFACE

Pressure transducer DMU 01K Compact version

Product Data Sheet , Rev GA Catalog Content

Armstrong In-Line and Insertion Vortex Flow Meters

Rosemount 3051CFA Annubar Flowmeter

SITRANS P measuring instruments for pressure

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

SATRON VTe pressure transmitter

SATRON VVFe Pressure Transmitter

VIM20 Vortex Insertion Flowmeter

Oriflow. Compact Orifice with HART communication. Operating instructions. A-EN RevC Latest Mod von 16

F-2600 SERIES INLINE VORTEX FLOW METER

SITRANS F M flow sensors 711/A and 711/911E

mass flowmeter for compressed air

Magnetic-inductive flow meter for hazardous areas

VIM20 Vortex Insertion Flowmeter

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

VORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter

RIM20 Rotor Insertion Flowmeter

OPTISWIRL 4070 Technical Datasheet

INTERPLANT STANDARD - STEEL INDUSTRY. Specification for Smart Pressure & Differential Pressure Transmitter

JUMO dtrans p20 DELTA

SITRANS F flowmeters SITRANS F C MASSFLO MASS MC1. 4/146 Siemens FI Overview

Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Rosemount 405 Compact Orifice Series

Plastic tube variable area flowmeter for liquids and gases

Rosemount DP Flowmeters and Primary Elements

Vortex In Line Flow Meter

Model 8800C Vortex Flowmeter

Features/Benefits INSTALL IT & FORGET IT FEATURES & BENEFITS

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57

Level Probes multicap T DC 12 TE multicap T DC 11/16/21/26 TEN/TES

SITRANS F M. Flow sensor MAG 1100 F 3/59

Smart Pressure Transmitter

LCMass Series Mass Flow Sensor

Vortex In Line Flow Meter

VORTEX IN-LINE FLOW METERS

Vortex Flow Meter Model DVH

Resistance thermometer Model TR10-E, for additional thermowell

Turbine flowmeters Series TM

Rosemount 485 Annubar Pak-Lok Assembly

Differential Pressure Gauges (701P Series)

Rosemount DP Flowmeters and Primary Elements

PETROL. Double Case PD Flowmeters. Trust in us Our Quality Counts. Technical Bulletin. PETROL Instruments S.r.l.

BM 26 BASIC/ADVANCED Technical Datasheet

JUMO dtrans p20. Process pressure transmitter. Brief description. Special features. Block diagram. Approvals/approval marks (see "Technical data")

Rosemount 8800D Series Vortex Flowmeter

Measuring insert for resistance thermometer Model TR10-A

Rosemount 8800D Series Vortex Flowmeter

Masoneilan Series

BM 26 BASIC/ADVANCED Technical Datasheet

STAINLESS STEEL ARES PNEUMATIC ANGLE-SEAT VALVE

Flow Measurement SITRANS F M

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

Rosemount Product Data Sheet , Rev GA Catalog FIELDBUS PROTOCOL. Hazardous Locations Certifications

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

Rosemount 3051T In-Line Pressure Transmitter

Datasheet MATRE Foam Inductors. Datasheet for MATRE Foam Inductors. 1 Contents

Annubar Flowmeter Series

KDM ARMORED FLOW METER & SWITCH

Transcription:

Typical Applications ORIMAS Mass Flowmeter The ORIMAS mass flow meters measure the mass flow of most liquids and gases within the process industries, including chemical, petro-chemical, pharmaceutical and the power industry. The ORIMAS is based on the principle of measuring velocity, the static pressure and the temperature in the pipe line. The electronics computerise the mass flow by using the 3 measured values. The ORIMAS flow meters are backed by international standards covering flow calculation, manufacturing tolerances, accuracy and installation requirements. This type of bare bone technology is world wide accepted and supported by millions of successful installations. Features The ORIMAS mass flowmeter features are: Standardised product based on well proven technology. Compact design. Simple construction. Free choice for horizontal or vertical pipe run. Standardised construction means low inventory. No moving parts. Not sensitive to vibrations. The electronics delivers output signal linear to mass flow. Digital indicator for local mass flow reading. High accuracy. Wide rangeability. Easy to install. Easy to re-calibrate. Fully in compliance to PED 97/23 EC Model with integrated manifold valve. 0-03-065-1e 1 of 6

Construction Model OR1 The ORIMAS flow meter model OR1 consists of a primary element based on the differential pressure principle, a 3 valve manifold, a multi variable transmitter and a temperature sensor. The multi variable transmitter measures the differential pressure, the static pressure and has an input connection to the temperature sensor. The flow computer housed in the transmitter performs the dynamic flow calculation. Model OR2 The ORIMAS flow meter model OR2 consists of a primary element and operates as mentioned above but has an integrated 3 valve manifold. The ORIMAS flow meter is mounted between flanges in sizes from DN 40 (1½") to DN 400 (16") in pressure ratings up to PN 40 (). Other sizes and pressure ratings on request. Accessories Model OR1 Remote Mounting Kit type RMK is available if remote mounting of electronics is required in case of not easy accessible pipe line or elevated process temperature. The customer has to provide the stainless steel instrument tube Ø 12 x 1 mm between flow meter and electronics. Remote electronic indicator with LCD is available for local flow indication and if required check/change of flow rate (differential pressure). Principle of measurement The ORIMAS is a mass flow meter A restriction in a pipe line changes the value of the different energies. Based on the law of energy balance developed by Bernoulli the sum of energies remains constant. Increases the velocity in the pipe line decreases the pressure in the restriction. The pressure differential between the inlet pressure and the pressure in the restriction is measured expressing the flow velocity. The static pressure and the temperature is measured. When the physical values of the fluid is known and the inner pipe diameter is established the electronics calculate the mass flow. The mass flow is expressed in an analogue signal 4-20 ma or signal for digital communication. Model OR2 0-03-065-1e 2 of 6

Technical data Sizes : DN 40 - DN 400, 1½" - 16", larger sizes on request Pressure rating : up to PN 40,, higher pressure ratings on request Temperature : Process : -50 - +150 C, higher temperature with Remote Mounting Kit Mounting style : Between flanges according to DIN or ANSI standards Flange facing : flat face (standard), raised face, DIN 2512 N, DIN 2513 R Overall length : 120 mm Material : Stainless steel AISI 316, others on request Design and calculation standards : ISO 5167, ASME MFC-3M. Vent or drain hole : On request β (d/d) : 0,5 and 0,6; other β on request. Accuracy : + /- 1 % Rangeability : 8 : 1 Repeatability : better than 0,1 % Pressure loss : typical 150 mbar for liquid flow, and 50 mbar for gas flow (values are given at full flow) Reynolds No : Re > 5000 Allowable differential pressure : max 2,5 bar Output signal : analogue 4-20 ma or digital communication via protocol, HART, PROFIBUS, Fieldbus Foundation or others. Local indicator (option): LCD showing flowing units or % Power supply : 14-36 Vdc, typical 24 Vdc. Max load (24 Vdc) : 700 Ohm Enclosure : IP 67 Ex protection : intrinsically safe EEx ia IIC T6, Explosion proof EEx d IIC T6 Temperature : Ambient : -40 - +80 C 0-03-065-1e 3 of 6

Sizes DIN flanges Size Pipe Pressure ß = 0,5 ß = 0,6 Inner pipe diameter OD rating Bore Bore B A1 A2 DN 40 48,3 PN 40 43,1 21,5 26,0 90 147 157 DN 50 60,3 PN 40 54,5 27,3 32,0 107 156 166 DN 65 76,1 PN 40 70,3 35,0 42,0 127 166 176 DN 80 88,9 PN 40 82,5 41,0 49,5 142 173 183 DN 100 114,3 PN 16 107,1 54,0 64,0 162 183 193 DN 100 114,3 PN 40 107,1 54,0 64,0 168 186 196 DN 125 139,7 PN 16 131,7 66,0 79,0 192 198 208 DN 125 139,7 PN 40 131,7 66,0 79,0 194 199 209 DN 150 168,3 PN 16 159,3 80,0 96,0 218 211 221 DN 150 168,3 PN 40 159,3 80,0 96,0 224 214 224 DN 200 219,1 PN 16 207,3 104,0 124,4 273 239 249 DN 200 219,1 PN 25 206,5 104,0 124,4 284 244 254 DN 200 219,1 PN 40 206,5 104,0 124,4 290 247 257 DN 250 273 PN 16 260,4 130,0 156,0 329 267 277 DN 250 273 PN 25 258,8 130,0 156,0 340 272 282 DN 250 273 PN 40 258,8 130,0 156,0 352 278 288 DN 300 323,9 PN 10 309,7 155,0 185,0 378 291 301 DN 300 323,9 PN 16 309,7 155,0 185,0 384 294 304 DN 300 323,9 PN 25 307,9 155,0 185,0 400 302 312 DN 300 323,9 PN 40 307,9 155,0 185,0 417 311 321 DN 350 355,6 PN 10 341,4 170,0 204,0 438 321 331 DN 350 355,6 PN 16 339,6 170,0 204,0 444 324 334 DN 350 355,6 PN 25 339,6 170,0 204,0 457 331 341 DN 350 355,6 PN 40 338,0 170,0 204,0 474 339 349 DN 400 406,4 PN 10 392,2 195,0 234,0 489 341 351 DN 400 406,4 PN 16 390,4 195,0 234,0 495 350 360 DN 400 406,4 PN 25 388,8 195,0 234,0 514 359 369 DN 400 406,4 PN 40 384,4 195,0 234,0 546 375 385 ANSI flanges Size Pipe OD 2" 60,3 3" 88,9 4" 114,3 6" 168,3 8" 219,1 10" 273 12" 323,9 14" 355,6 16" 406,4 Sch. 10S Sch. 40 Sch. 80 Pressure ß = 0,5 ß = 0,6 rating Inner pipe Inner pipe Inner pipe B A1 A2 Bore Bore dia. dia. dia. 150 lbs 104,8 154 164 54,7 52,5 49,3 26,0 31,5 111,1 158 168 150 lbs 136,5 170 180 82,8 77,9 73,7 39,0 47,0 149,1 177 187 150 lbs 174,6 189 199 108,2 102,3 97,2 51,0 61,0 181,1 193 203 150 lbs 222,3 213 223 161,5 154,1 146,3 77,0 92,5 250,7 227 237 150 lbs 279,4 242 252 211,5 202,7 193,7 101,0 121,6 308 256 266 150 lbs 339,7 272 282 264,6 254,5 242,8 127,0 153,0 362 283 293 150 lbs 409,6 307 317 314,7 303,2 289,1 150,0 180,0 422,3 313 323 150 lbs 450,9 327 337 346 333,3 317,5 165,0 198,0 485,8 345 355 150 lbs 514,4 359 369 396,8 381 363,6 190,0 228,0 539,8 372 382 0-03-065-1e 4 of 6

Overall dimensions Installation requirements The ORIMAS flow meter can be mounted in a horizontal or vertical pipe. For liquid flow in a horizontal pipe the electronics shall be mounted below the pipe. For gas flow in a horizontal pipe the electronics shall be mounted above the pipe. To insure high accuracy of measurement, long straight pipe runs upstream from the mass flow meter is necessary. The required straight pipe run depends on the disturbance upstream. To maintain the 1% accuracy the minimum straight pipe run upstream shall be 14 x inner pipe diameter and 6 x downstream If an additional inaccuracy of ½ % is acceptable the required straight pipe runs are reduced to half of the above values. Saturated steam is covered by STEEMCO flow meters with multi variable transmitter and superheated steam is covered by STEEMCO-MAS flow meters 0-03-065-1e 5 of 6

ORIMAS coding 1. Type 2. Size In AISI 316 with transmitter flange code OR1 integrated manifold code OR2 DN 40, DIN standard code 040 DN 50, DIN standard code 050 DN 65, DIN standard code 065 DN 80, DIN standard code 080 DN 100, DIN standard code 100 DN 125, DIN standard code 125 DN 150, DIN standard code 150 DN 200, DIN standard code 200 DN 250, DIN standard code 250 DN 300, DIN standard code 300 DN 350, DIN standard code 350 DN 400, DIN standard code 400 1½, ANSI standard code 01.5 2, ANSI standard code 002 3, ANSI standard code 003 4, ANSI standard code 004 6, ANSI standard code 006 8, ANSI standard code 008 10, ANSI standard code 010 12, ANSI standard code 012 14, ANSI standard code 014 16, ANSI standard code 016 3. Pressure rating PN 10, DIN standard code 10 PN 16, DIN standard code 16 PN 25, DIN standard code 25 PN 40, DIN standard code 40 150 lbs, ANSI standard code 15, ANSI standard code 30 4. Facing DIN 2526 Form A code 26 DIN 2513 Form R13 code 13 DIN 2512 Form N code 12 Raised face RF, ANSI std. code RF Flat face FF, ANSI std. code FF 5. Pipe schedule ( only applicable for ANSI flanges) DIN flanges code 00 Schedule 10S code 10 Schedule 40 code 40 Schedule 80 code 80 6. β value β value 0,5 code 5 β value 0,6 code 6 β value free choice code 9 7. Drain/vent hole Ø3 mm Without drain/vent hole code 0 With drain/vent hole code 1 8. manifold valve OR1 - Without code 0 OR1-3 valve manifold code 1 OR2 - Integrated 3 valve code 2 9. Differential pressure transmitter Without code 0 Included code Original transmitter type no. 10. Pt 100 temperature sensor 1/1 DIN, Form B head, alu. code 0 1/2 DIN, Form B head, alu. code 1 1/3 DIN, Form B head, alu. code 2 1/1 DIN, Form B head, 316. code 3 1/2 DIN, Form B head, 316. code 4 1/3 DIN, Form B head, 316. code 5 Examples DN 100 ORIMAS in stainless steel PN 40 with DIN 2526 facing, β value 0,6, without drain/vent hole and 3 valve type G3H double flanged manifold valve, and without transmitter, but with Pt100 1/1 DIN element in Form B head has following code: OR1-100-40-26-00-6-0-1-0-0 8 ORIMAS in stainless steel 150 lbs with RF facing with β value 0,5, with drain/vent hole, with integrated 3 valve manifold and Yokogawa differential pressure transmitter type EJX 110A has following code: OR2-008-15-RF-40-5-1-2-EJX110A-0 Remote mounting kit type RMK is ordered separately. 0-03-065-1e 6 of 6