SolidFlow. Monitoring of Solids. Product Information. SWR engineering Messtechnik GmbH

Similar documents
Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH

DensFlow D. Superior with Solids. Flow measurement for densphase conveying. Operating Instructions

DIAMOND POINT VIBRATING PROBES

DRYRAPID. The versatile dry feed conveying system

Continuous level measuring system NB 3000 Selection list. Overview

NIVOCONT R VIBRATING ROD LEVEL SWITCHES

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

VersaFlow Vortex 100 Vortex Flow Meter Specifications

System Electropneumatic Converters (Proportional Valves) Electronic Process Controllers Signal Converters

SMARTWOOD SRL Via Caduti sul don, Villar San Costanzo (CN) Tel

DSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity

UFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater

Safety drying oven with expended temperature range

Continuous level measuring system NB 3000 Selection list

JesHopper. Supplier for The grain and feed milling industry The food industry The chemical/technical industry

Flow VA 500/ 520. Flow sensors for compressed air and gases incl. temperature measurement. Verbrauch.

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

MAIN FUNCTION FEATURES. . D = v t /2

Level measurement Guided microwave Product Information VEGAFLEX ma/hart. Level Switching Pressure

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

Soliswitch FTE20. Technical Information. Point level switch for granular solids

Safety drying ovens. Advantages: Areas of application: FDL series 115

Machine Specification

Soliswitch FTE30. Technical Information

Heating chamber with mechanical convection

CVR-625. Compact Vibrating Rod Instruction Manual

Vortex Flow Meter Model DVH

Safety drying ovens with expanded temperature range

Ultrablend UB 975. Dosing and Blending: Gravimetric Dosing Systems. Description. Rugged, modular construction

Magnetic Inductive Flow

Controller Specification Sheet

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam

MC-Balance product information

MPS AND MPS PR¼ 16 OUTPUT DEMAND CONTROLLER PENTAIR CLEAN AIR SYSTEMS. AVS Danmark ApS Skelvej Hedehusene

... PureLine PQ. Technical Specification. PureLine PQ (Disinfection) Models PQ PQ UV Chamber. Cabinet

Measuring Systems for Solids

Multivariable Vortex Flow Meter

Heating chamber with mechanical convection

Solenoid Valves Type 3963

Flow Measurement SITRANS F C

Data Sheet SCHISCHEK EXCOS-P. Pressure sensor 20 Pa Pa. Supplied by. .com. Call us on +44 (0)

Oxiperm 164 D for 30 to 2000 g/h

VARIO. VARIO Separation of fine dust particles. The VARIO series is particularly suitable for separation of fine dust.

MFKG Single-Shaft Continuous Mixer. Intensive mixing of fine materials

Oil & Gas Lubrication Systems

Standard Duty A.T.S.A. - Temp Desuperheater Model 24 / 34

Oxiperm 164 C for 150 to 2500 g/h

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

Multivariable Vortex Flow Meter

SITRANS FX300 4/289. System Overview. Overview

AERZEN BULK VEHICLE BLOWER

Level MONITORING. Continuous Level Measurement ILS

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

System description for cylinder lubrication and valve seat lubrication on large 4-stroke diesel engines

Heating chamber with mechanical convection

EAS822 (Contrac) Power Electronic Unit

Operating Instructions Type MPT 53

OPTISWIRL 4070 Technical Datasheet

Liquid feeding Dry feeding. Electronic sow feeding. House equipment. control technology. Environmental. Liquid manure treatment. Dry feeding...

DVH. Vortex Flowmeter. Measuring range: Nm³/h. Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Fax: 219/

Online data sheet S710 E S700 EXTRACTIVE GAS ANALYZERS

Flow meter Type Recordall (RCDL)

MAIN FUNCTION FEATURES. . D = v t /2

Orifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam

Schenck Process industrial air filters the smart dust collection solution

BULK SOLIDS FEEDING. Distributor of. Rotary Valve RV RVR RVR

OPTISWIRL 4070 Technical Datasheet

Obermann Grouting System Dosing - Grouting - Monitoring

BD SERIES BLENDERS Batch Weigh Blenders

INFASTAUB. Breathe The Difference: Pure Air. INFA-JETRON Silo filter / Dust collector

Heating chamber with mechanical convection

Differential pressure transmitter PASCAL Ci4 Delta P

Product Overview. Rotary Encoders for Potentially Explosive Atmospheres (ATEX)

VANTIX Series Optimized Technology

Air volume 24 m³/h (14.1 CFM) Rated power 13 W Size (14.1) 55 (32.4) 100 (58.9) Air volume (with exhaust filter installed)

UWT Lot. Table of contents. Continuous level measuring system SLS 3000 Technical information / Instruction manual. Page

mass flowmeter for compressed air

Dry Chemical Feed Systems

VERTICAL FORM FILL SEAL MACHINES

Continuous Level Measuring System. LevelMax. Instruction Manual

Viscosense 3. Viscosity Measurement & Control Systems. Product Bulletin TO BE REALLY SURE

SmartBob AO. BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE

WATERFLUX 3070 Quick Start

F-2600 SERIES INLINE VORTEX FLOW METER

Volumetric Chamber Metering

P U L S A R point 210

Turbidity and Suspended Solids Transmitter

RAPIDMIX 400CW. Length of Machine (19.5m) Length when erected Width of Machine 9-10 (3.00 m) Width Same

Dosing Pump Operational Manual

Injection oilers, micro pumps

CS 420RC. Solid De-icer Controller Configuration and Set-up Manual

Capanivo Series CN 4000

Servotronic Digital 615 Series

NCR ma/hart four-wire

INSTALLATION GUIDE Ultrasonic Sensors Series UX micro

For reliable dosing of all granular and free flowing materials.

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

YARWAY NARVIK MODEL 33/43 STANDARD DUTY QUE-TEMP DESUPERHEATER

ViscoSense 3D. Viscosity & Density Measurement Enabling Mass Flow Measurement. Product Bulletin TO BE REALLY 1 SURE

Transcription:

EN SolidFlow Product Information Monitoring of Solids SWR engineering Messtechnik GmbH

Using SolidFlow is a sensor especially developed for measuring the flow rate of solids conveyed in metallic ducts. It has successfully been tested for online-measuring of: all types of dust, powder and granulates grain size between nm and cm pneumatically conveyed materials or in free fall after mechanical conveying systems SolidFlow is wear-resistant and the commissioning is very easy. Function The sensor is working according to the latest microwave technology. It is exclusively used in metallic ducts. A measuring field is produced by special linking of the microwave together with the duct. The microwave energy is reflected by the solid particles and received by the sensor. These signals are evaluated in frequency and amplitude. The sensor works like a particle counter, which counts the quantity of the moving particles per time unit. Due to the selective frequency evaluation only moving particles are measured and deposits are ignored. The calibration of the sensor is made in the inserted condition, simply by pushing a button and entering of the reference quantity. f f0 Measuring System A complete measuring system consists of the following items: Socket for mounting the sensor inclusive dummy plug Sensor FMS with a connecting cable of meters Transmitter FME with totalizer C-Box for connecting sensor transmitter Sensor C-Box Transmitter The C-Box is not implicitely necessary, thus an adequate tool can be used by the customer. In case of a wrong connection the C-Box ensures the protection of the sensor. max. 000 m

Applications Practical Examples Proportioning System 500 kg/h The mixtures are created with a weighing hopper in a sandwich-like manner. There are problems with the dosage of the small quantities of the additional ingredients. For the weighing of the small quantities, the balance is not laid out, so that the proportioned quantities are not reproducible. Rotary value M Exhauster Balance By using SolidFlow the dosage of the additional ingredients becomes reproducible and a better balance of the used quantities is possible. different types of malt (0, mm Ø) Mixer DN50 Stainless Steel Secondary Fuel Output,5 t/h At a boiler types of dust are conveyed into the combustion chamber as secondary fuel. As no information is available about the distribution of the fuel quantity in the different feeding pipes, there is not always an optimal adjustment of the combustion possible. Compressed gas Fuel (-dust) approx.,5 t/h Granulation approx. µm Each feeding pipe is monitored by a SolidFlow and the supply of the fuel quantity in each individual feeding pipe is regulated. Thereby an exact uniform distribution of the fuel quantities is guaranteed, which is an essential condition for optimal combustion. Fluid-Gas (N) Pressure bin Combustion chamber DN50 Steel Pipe Primary Fuel Totalizing 0 t/h The material supply from the silo to the separator is subject to strong fluctuations. to the mill By using SolidFlow the progress of the mass flow is measurable and can be documented. If necessary, a regulation can take place. By the measurement of the coarse grain from the separator to the mill the meal quality can also be monitored in the future. 40 m DN50 Riser, Granulation approx. 5 0 µm for further Processing Lime hopper Classifier

Free Fall Applications 00 kg/h The conveyed cement quantity is measured by a belt weigher. This measured value forms the reference input for the measuring of iron-ii-sulphate. This has to be made with a proportion of 0. 0. percentage. Iron-II-Sulphate hopper By using SolidFlow the actual value of the measured iron-ii-sulphate is measured and regulated by the velocity of the screw feeder. The result is a constant product quality. DN50 Sheet metal pipe Granulation 40 60 µm Polystyrene Proportioning System 400 kg/batch Small polystyrene pellets are supplemented as additional building material into the solid mixer. The quantity is determined by the measured volume of the bin. 4 Sliding valve M Pump Filter Solid Mixer 5 By using SolidFlow the measured quantity of polystyrene pellets can be measured directly. A complicated, intermittent volume regulation is not necessary any longer. By achieving the weight preselection the conveyance is stopped. The result is a substantially improved product quality as well as a substantially improved cost-benefitratio. Granulation 0,8 mmø Polystyrene hopper 4 Lime for plastering Bin 5 Mixer DN00 Steel Pipe (Proportioning line) 6 for sack filling 6 Sliding valve Granulates Proportioning System 400 kg/batch The existing proportioning weigher is too inaccurate and permitted only an intermittent operation of the system. M By using SolidFlow the monitoring of the conveyed quantities becomes transparent and the proportioning can be changed to a continous operation. Granulation 00 µm 4 Granulation hopper Proportioning weigher (no longer necessary) Mixing chamber 4 DN50 Steel Pipe 4

Mounting and Installation For the mounting of the sensor the fitting position will be determined according the inlet and outlet section. In case of duct diameters greater than Ø 00 mm one has to install or sensors per measuring unit, which are located 50 mm apart from each other and moved by 90 resp. 0 towards each other. With free fall applications (e. g. after screw feeders or rotary valves) a free fall height of at least 00 mm would be perfect. The sensor accommodation (socket) will be welded on at the fixed position. Subsequently drill a Ø 0 mm hole into the duct. Then you have to adapt the sensor to the wall thickness and with the help of the union nut fixed. Ready to measure! Hopper 5 x DN DN 8 x DN (min. m) 0 x DN (min. m) 8 x DN (min. m) x DN 8 x DN 0 x DN 8 x DN 00 A B A B Commissioning The commissioning of the measurement is made by the transmitter FME. This unit offers a comfortable, menu-guided input of the parameters, e. g. the measuring range, the requested physical unit or measuring signal absorption. A current or voltage output, 4 0 ma or 0 V, are available as exits and also an impulse output (Open- Collector). A totalizer enables an easy calibration. Furthermore this gives the possibility to check totally conveyed quantity. The menu language is free-selectable between German, English or French. 5

Sensor Messumformer Product Information Technical Data Sensor / Sensor accomodation Housing Stainless steel.457 7 Protection category Operating temperature front end of sensor optional sensor electronic Max. Working pressure Working frequency Transmitting power Weight IP 65, DustEx 0 or GasEx (option) -0 +80 C [-4 +76 F] -0 +00 C [-4 +9 F] +0 +60 C [+ +40 F] bar, optional 0 bar K-Band 4, 5 GHz, ±00 MHz Max. 5 mw. kg 78 Dimension Ø 60, Ø 0, L 7 mm 44 Accuracy Transmitter Supply voltage Power consumption ± 5 % in calibrated range 0/0 V, 50 Hz (optional 4 V DC) 0 W / 4 VA 7 90 0 64 4 98 86 4 6 Current consumption Max. A at 4 V Protection category IP 65 according to EN 60 59/0.9 Operating temperature -0 +45 C [+4 + F] 58 Enclosure dimensions 58 x 7 x 74 (W x H x D) Weight Interface Approx..5 kg RS 485 / RS C (ModBus) Cable glands x M6 (4.5-0 mm Ø) Screw terminals 0.-.5 mm [AWG 4-4 Current output signal Measurement value alarm relay output Data storage Pulse output 4 0 ma (0 0 ma), load < 500 Ω Relay with switching contact Max. 50 V AC, A Flash Open Collector - Max. 0 V, 0 ma C-Box Size 98 x 64 x 5 mm (W x H x D) certificated according to ATEX SWR engineering Messtechnik GmbH Gutedelstraße 7948 Schliengen (Germany) Fon +49 765 8 7 48-0 Fax +49 765 8 7 48-48 www.swr-engineering.com (All rights reserved.) 6 EN 0/0/8