TXH TOTAL EXHAUST HOOD. Installation and Operations Manual

Similar documents
EXT DUCTLESS FUME HOOD

EXT HEPA/CARBON FUME HOOD

FUME HOOD. Installation and Operations Manual

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

CLEAN AIR WORKSTATION REVERSE FLOW. Installation and Operations Manual

VCM LAMINAR FLOW HOOD VERTICAL

Further information: Berriman Associates Model 850P.2 Owners Manual

Model G14SD Vapor Management System

After installing the HEPA filters the discharge air should be monitored to ensure proper filtering efficiency. HEPA Filters

MODEL 950C-NP-UV Installation and Owners Manual

Operations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD

Series 301. Horizontal Laminar Flow Clean Bench. C l e a n B e n c h e s. s o l u t i o n s. Series 301 Horizontal Laminar Flow Clean Bench

A. Each cabinet must be constructed and installed in accordance with EN12469:2000.

INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS. Part Number: P DM

Miracle State Of The Art Air Filtration System!

User s Manual and Operating Instructions

Complete Whole House Air Cleaning System Photronic Base Media Air Cleaner OWNERS GUIDE

SPH General Manual 400 Series

MODEL MC1500 Installation and Operation Manual Important:

FAN POWERED HEPA FILTER UNIT

ADVANCED SAFETY ENGINEERING FOR EFFECTIVE HANDLING OF HAZARDOUS PARTICULATE DRUGS AND POWDERS IN A CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET

PUREAIR AIR PURIFICATION SYSTEM PHOTOCATALYTIC OXIDATION (PCO) TECHNOLOGY

Cincinnati, OH USA

PHOENIX MINI-GUARDIAN

Instruction Manual. Fudge Puppy Display Case


HEPA AIR FILTRATION SYSTEM

Integrated Heating System

BioMAX. Koch Filter Corporation. A Complete Line of HEPA Filters for Hospital, Commercial and Industrial Applications

Junior Sandblaster. Model #51 WARNING! FOR YOUR SAFETY PLEASE READ INSTRUCTIONS BEFORE OPERATING TOOL & WEAR EYE PROTECTION

AUTO-PUMP 120 VAC AIR COMPRESSOR SYSTEM INSTRUCTION MANUAL. 170 Cherry Avenue West Sayville, NY

READ AND SAVE THESE INSTRUCTIONS. Air Boss MP600M Vertical Air Flow Mist Precipitator Industrial Applications. TRION

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

MODEL FA1 Mini Air Filtration System. Operations Manual

INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT & DIRECT DRIVE XB, HV, HVA, ADD, DDS, DDP

PHOENIX GUARDIAN H. E. P. A. SYSTEM

LABGARD FEATURES

SECTION HVAC AIR CLEANING DEVICES

D-Series Blowers and Exhausters

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL

QPET, QPETXU Battery Chargers

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

INSTALLATION, MAINTENANCE & OPERATION GUIDE. MODEL Sanuvair S300 WHOLE HOUSE HEPA/UV AIR PURIFIER. ITEM # Sanuvair S V EN

Dispenser & Warmer RIC-1909 RIC-1909EXP

FADE Series Wall Axial Fans

Installation & Service Manual for Portable Fume Collector. Model PFC-800

NUTONE RANGE HOOD NTM SERIES

Air Curtain. Installation, Operating and Maintenance Instructions

Nilfisk-CFM SS Vapor Vacuum Instructions for Use and Spare Parts Manual

Maintenance Instructions

OBAE, OBAEXU, ON BOARD Battery Chargers

VLF-797 CLEAN BENCH INSTALLATION AND SERVICE MANUAL Volt Model Volt Model

SAFETY INSTRUCTIONS Before installation and operation, read these instructions carefully and use this product only in the manner described by the manu

User s Manual D-Series Blowers and Exhausters

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com BVX-100. Fume Extraction System _B

MODEL MA4210 Installation and Operation Manual Important:

TABLE OF CONTENTS SPECIFICATIONS 3 INSTALLATION 4. Direct Mount 4. Ducted Installations 5. Installing Plenum 5. Machine Mount Stand 5.

INSTALLATION INSTRUCTIONS

we make clean air Air Filtration Solutions Industrial Commercial Residential quatroair.com AIR TECHNOLOGIES INC.

LAMINAR FLOW HORIZONTAL FLOW BENCH (LF) OPERATION & MAINTENANCE MANUAL

Biological Safety Cabinet

INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT DRIVE XBL FANS

PerfectPleat. PerfectPleat M8 ULTRA. PerfectPleat. Better Air is Our Business. 4" Extended Surface Pleated Filters. DuraFlex - AAF s Patented Media

Soldering/Desoldering. Convection Rework. Fume Extraction. Fluid Dispensing

ALUMAREEL. Electrical Cord Reel. Model EC6 100 Model EC Operational, Maintenance and Installation Manual

COMPACT GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

ADI-125/750 ADI-125/1500 ADI-125/2500

Source Capture Air Purification System

WELDING FUME EXHAUSTERS & ARMS

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

GE Monogram. Installation. Instructions. Professional Vent Hoods. 48" Models ZV881WSS, ZV891YSS ZV880WSS, ZV890YSS. 36" Models ZV671WSS, ZV681YSS

TH Series UL 900 Class 1, Factory Mutual Approved, Truly Separatorless Filter Modules

QSSE, QSSEX INDUSTRIAL Battery Chargers

THIS PRODUCT IS FOR PROFESSIONAL LABORATORY USE ONLY USER'S MANUAL. WELLS ENGINE UNIT 230 VOLT Product No. U905, U906, U907, U908

OBE, OBEXU, ON BOARD Battery Chargers

Quest DRY 150. Quest PowerHEPA 500. quest. Read and Save These Instructions. Quest PowerHEPA 500:

AIM LED LIGHT (wall mount)

LFDCX LAMINAR FLOW DIFFUSER WITH INTEGRATED HEPA FILTER

MODEL SCA Installation and Operation Manual Important:

TWIN HALOGEN SHOP LIGHT

Class II Biological Safety Cabinets The World's Most Energy Efficient, Quiet, and Compact Biosafety Cabinet

Automotive Air Conditioning Manifold Gauge Sets

FE-WS6 Downflow Ductless Workstation. Operator s Manual

HA/HAB Fiberglass Wall Mount Ventilators

R E A D T H I S F I RST SAW USER GUIDE MODEL SVC4

TRAILER WINCH MODELS ST315 AND ST712. General Safety (Continued) Description. Unpacking. General Safety Information.

Compressor Duty Motor - 1 HP. Model 40132

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

Requires Ductwork and Blower

Protector XStream Laboratory Hood is shown with SpillStopper Work Surface , Protector Acid Storage Cabinet and Protector

Bayside Model BU2050 Installation, Maintenance, and Operation Manual

BIOLOGICAL SAFETY CABINET

HP190SL Series Slimline Radon Fans

Product Data. FNCCAB & FILCCFNC High Efficiency Fan Coil Filtration. Sizes 014, 017, 021 & 024. FNCCAB Filter Cabinet. FILCCFNC Media Filter

Powerful & Intelligent Submersible Pumps

WS-Series. Operating Instructions. Pulse DC End Area Coils. Drilco Style WS-Series Coils 1. E s t a b l i s h e d WS-14 WS-12 WS-10 WS-8

INSTALLATION VARIABLE FREQUENCY DRIVE THREE PHASE ALX SERIES SPUN ALUMINUM EXHAUSTERS

Model Numbers: MAC-36-BDF, MAC-42-BDF, MAC-48-BDF CONSUMER: READ AND SAVE THESE INSTRUCTIONS

General. Technical Bulletin: ACCESSORY INFORMATION

Transcription:

TXH TOTAL EXHAUST HOOD Installation and Operations Manual

TXH TOTAL EXHAUST HOOD Installation and Operations Manual Revision: 25-Nov-16 Page 2 of 12

TXH TOTAL EXHAUST HOOD Installation and Operations Manual Revision: 25-Nov-16 Page 3 of 12 TABLE OF CONTENTS 1. SHIPPING AND UN-CRATING... 4 2. INSTALLATION... 4 3. PRE-FILTER... 6 4. PRE-FILTER MAINTENANCE... 7 5. HEPA FILTER... 7 6. ULPA FILTER... 7 7. CHANGING HEPA/ULPA FILTERS... 7 8. CHANGING THE FLUORESCENT LIGHT... 8 9. SPEED CONTROL... 8 10. EXHAUST SYSTEM SAFETY PRESSURE SWITCH... 8 11. MODEL NUMBER... 8 12. MOTOR/ELECTRICAL... 8 13. CHANGING SASH WINDOW CABLES... 8 14. TESTING & CERTIFICATION... 9 15. SPECIFICATIONS & DIMENSIONS... 10 16. AIRFLOW DIRECTION... 11 17. REPLACEMENT PARTS... 11 18. WARRANTY... 12

TXH TOTAL EXHAUST HOOD Installation and Operations Manual Revision: 25-Nov-16 Page 4 of 12 Thank you for purchasing our Total Exhaust Hood, with proper care and maintenance your hood will provide you with many years of trouble free performance. Please read instructions carefully before installing and operating your Total Exhaust Hood. WARNING: TO REDUCE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS PLEASE REVIEW THE FOLLOWING PRECAUTIONS. Do not expose your Total Exhaust Hood to rain or moisture. Always disconnect the Total Exhaust Hood from power supply when servicing, moving parts may cause serious injury. Always disconnect while grasping the plug, not the cord. Do not expose Total Exhaust Hood to gaseous or explosive vapors. Motors normally spark and may ignite fumes. Do not block airflow to top or back of unit, allow at least 5 above unit Do not modify the plug of your hood if it will not fit in your duplex outlet. Have a proper outlet installed by a qualified electrician. Use only specified replacement parts recommended by Design Filtration Microzone. Use this equipment only in the manner intended by Design Filtration Microzone. 1. SHIPPING AND UN-CRATING Your Total Exhaust Hood normally is shipped in two sections; smaller units may come fully assembled. Units should be stored in heated conditions of between 4 C (40 F) and 32 C (90 F) to avoid undue structural fatigue and damage. Each unit is factory tested for airflows and filter leaks prior to shipping. On occasion damage can occur during the transportation of your new Total Exhaust Hood. Carefully remove the crating from your hood and inspect for damage that may have been caused and report it immediately to your transportation company. All shipments are F.O.B. Design Filtration Inc. You must file a claim directly with the freight carrier. Design Filtration Inc. and its dealers are not responsible for shipping damages. 2. INSTALLATION Once in location it is recommended that your hood be re-tested for airflows and leaks by an independent testing organization with technicians trained in the evaluation and maintenance of HEPA filtered equipment. Always use safe lifting guidelines when installing your hood on a base frame or existing work bench. Do not use a lift truck when moving your Total Exhaust Hood. Leave your hood on the shipping skid until it is in its final installation location. Never lift from the centre of the hood. Allow hood to acclimatize to room temperature, before installation.

TXH TOTAL EXHAUST HOOD Installation and Operations Manual Revision: 25-Nov-16 Page 5 of 12 WARNING: ALLOW 24 HRS FOR HOOD TO ACCLIMATIZE BEFORE INSTALLATION, TO PREVENT DAMAGE TO HOOD. WARNING: ALWAYS LIFT FROM THE OUTSIDE EDGES OF HOOD TO PREVENT DAMAGE. DO NOT USE FORK LIFT ON CENTER OF HOOD. Your Total Exhaust Hood is shipped to you in four pieces. To start, locate the base frame as close to the final area as possible, allowing enough space for the head section and personnel to move freely around the front or back. Place the wood blocks supplied, angled across the corners of the work surface, as shown in Figure 2.1. Raise the head section keeping as straight as possible. Move head section over base, and gently lower on the wood pieces, avoiding damage to fingers. Lifting one end at a time remove wood spacers and lower to base section, aligning connection screws as shown. Figure 2.1

TXH TOTAL EXHAUST HOOD Installation and Operations Manual Revision: 25-Nov-16 Page 6 of 12 Lift rear plenum and align with pre-drilled holes, see Figure 2.2. Insert all of the screws before tightening them. Connect plastic tubing to fitting on transition. Supply fans will not run unless tubing is connected. Figure 2.2 3. PRE-FILTER Your Total Exhaust Hood is equipped with disposable pre-filters, which are manufactured from a bonded synthetic media set into a moisture resistant beverage board. Pleated pre-filters carry an efficiency rating of MERV 7 (Minimum Efficiency Reporting Value). The filters also provide an Average Atmospheric Dust Spot Efficiency of 25-30% to ASHRAE Test Standard 52.1.

TXH TOTAL EXHAUST HOOD Installation and Operations Manual Revision: 25-Nov-16 Page 7 of 12 4. PRE-FILTER MAINTENANCE Please check your pre-filters on a monthly basis and change as necessary. To change your pre-filter simply remove old pre-filters and replace with new pre-filters. No tools are required 5. HEPA FILTER Your Total Exhaust Hood features a 5.88 deep wood frame filter with a separator-less type media to provide excellent even airflows. The wet laid glass media is set into the frame with a urethane seal. Efficiency is 99.99% at 0.3-micron particle size and larger. HEPA filters cannot be cleaned and must be replaced when necessary, consult factory for replacement filters. 6. ULPA FILTER The optional ULPA filter is rated 99.9995% at 0.12-micron particle size and larger. Other features as per HEPA filter. ULPA filters cannot be cleaned and must be replaced when necessary. 7. CHANGING HEPA/ULPA FILTERS Before beginning to change your HEPA Filter, disconnect your hood from power source. Carefully remove front access panel to reveal interior compartment. Loosen threaded rods at front and rear of fan filter module. Unscrew and remove polypropylene front locating bar. Remove ¼ 20 nuts from rear clamping mechanism. Unplug fan power cords from electrical outlet. Carefully slide fan filter module from housing (this may require two people.) Remove aluminum foil tape and separate the filter from motor housing. See Figure 7.1. Carefully remove the new HEPA filter from crate. Using aluminum foil tape (do not use duct tape) complete at least 3 layers of tape joining the fan housing to the filter. Apply a thin layer of vacuum grease to gasket before reinstalling the filter. Carefully lift and place filter back Figure 7.1 into the hood making sure the HEPA filter is not damaged. When tightening threaded rods, do not over tighten as these are only used to hold filter housing in place. Once entire unit is re-assembled it must be tested and certified by a qualified certification company.

TXH TOTAL EXHAUST HOOD Installation and Operations Manual Revision: 25-Nov-16 Page 8 of 12 8. CHANGING THE FLUORESCENT LIGHT Carefully remove the screws on the lens cover, remove the bulb and install new bulb with same type and color as original supplied. Some new units have LED lighting. 9. SPEED CONTROL The speed control (SCR) controls the supply filtration only and is located in the top right-hand corner of the unit. It should only be adjusted by a qualified service technician. See Section 14 for full certification protocol. 10. EXHAUST SYSTEM SAFETY PRESSURE SWITCH This switch is located inside the head section and is connected to the exhaust collar via tubing. In the case of total or partial exhaust failure, this switch will turn off the supply fans and an alarm condition will sound. This can be silenced, but a red light will always be visible. This will ensure no possibly hazardous air will be blown out of the containment work zone. Supply fans will not run unless tubing is connected. Typical exhaust static pressure ranges from 0.65 to 0.8 at this point. 11. MODEL NUMBER The model number is located on the front panel in the lower right hand corner. The serial number and electrical information is also included on this label. Refer to these numbers when contacting the manufacturer. 12. MOTOR/ELECTRICAL The Total Exhaust Hood uses 115-volt, 124-watt energy efficient motorized impellers to provide excellent airflow distribution, quieter noise levels and low heat loads. Standard on your Total Exhaust Hood is a FT2 type CSA approved 3-prong electrical cord. Always unplug your hood when servicing. 13. CHANGING SASH WINDOW CABLES Should the event of a sash cable replacement be required lift the window as high as possible and support with two wooden studs cut to length. Remove the interior side panels (LHS and RHS), remove the old cable and support the weight with a temporary 2 high stand (this will compensate for stretching of the cable later). Attach new c dia. polypropylene rope, with a rating of at least 45lbs, to window end first. Thread through pulleys and secure around weight eyelet with cable as tight as possible. Always change both ropes at the same time. Consult factory for full rope specifications. Units manufactured after 2013 utilise coated stainless steel cables. Consult factory for replacement parts.

TXH TOTAL EXHAUST HOOD Installation and Operations Manual Revision: 25-Nov-16 Page 9 of 12 14. TESTING & CERTIFICATION a. Supply HEPA or ULPA Filter leak test Filter(s) should be leak tested prior to airflow balancing in accordance with IES-RP-CC-CC002.4. Please note some units are installed with optional PTFE filters and only particle counting can be performed. b. Supply air velocity Adjusting the airflow will affect the operation of your hood due to the critical balance required. Remove front snap cap located on the front panel to access the speed control. Use a flat headed screwdriver to adjust speed, turning clockwise to increase speed. After adjustment of the speed control, airflows should be checked to ensure it is within the specified range as outlined in chart and the plate on the front of the unit. Refer to IES standard IES-RP-CC-002.4. c. Hand intake volume Once the supply air velocity has been set, use a direct inflow measure device to measure the inflow volume. Ensure all closure panels are sealed prior to recording test results. Recorded intake airflow should be checked to ensure it is within the specified range as outlined in chart and the plate on the front of the unit. Exhaust fans may or may not need to be adjusted at this stage to obtain inward velocity of 100-110 fpm. (Some units may have reduced intake flows. Refer to NSFF.3.3.2 for direct inflow measurement methods.) d. Total exhaust volume To obtain the total exhaust volume, add the calculated supply volume to the recorded hand intake volume, plus allow for vented base cabinet. See Section 16 for airflow direction drawing. Consult factory for any other questions.

TXH TOTAL EXHAUST HOOD Installation and Operations Manual Revision: 25-Nov-16 Page 10 of 12 15. SPECIFICATIONS & DIMENSIONS TXH SERIES OF VERTICAL FULL EXHAUST WORKSTATIONS TECHNICAL INFORMATION NOV 2015 Model Number PHYSICAL DATA OVERALL UNIT DIMENSIONS WORK ZONE DIMENSIONS Width Depth Height Width Depth Height EXHAUST COLLAR SHIPPING WEIGHT IN (mm) IN (mm) IN (mm) IN (mm) IN (mm) IN (mm) IN (mm) LBS KG T XH - 4 52'' (1,321) 36.5'' (927) 93'' (2,362) 46.4'' (1,179) 31'' (787) 36'' (914) 10'' (254) n/a n/a T XH - 5 64'' (1,626) 36.5'' (927) 93'' (2,362) 58.4'' (1,483) 31'' (787) 36'' (914) 10'' (254) n/a n/a T XH - 6 76'' (1,930) 36.5'' (927) 93'' (2,362) 70.4'' (1,788) 31'' (787) 36'' (914) 10'' (254) n/a n/a T XH - 8 96'' (2,438) 36.5'' (927) 93'' (2,362) 90.4'' (2,296) 31'' (787) 36'' (914) 12'' (305) n/a n/a Model Number PERFORMANCE 10" HAND INTAKE BASE VENT DOWNFLOW * (Intake Velocity Range 100-110 fpm) (Downflow Velocity Range 55-65 fpm) CFM (M 3 /hr) CFM (M3/hr) CFM (M 3 /hr) CFM TOTAL AIR EXHAUST T XH - 4 322-354 (547-602) 40 68 425-502 (723-853) 787-896 (1338-1523) T XH - 5 405-446 (689-758) 50 85 535-632 (910-1074) 990-1128 (1683-1918) T XH - 6 489-538 (831-915) 60 102 645-762 (1097-1295) 1194-1360 (2030-2312) T XH - 8 628-690 (1068-1173) 80 136 828-979 (1408-1664) 1536-1749 (2611-2973) (M 3 /hr) * Downflow is measured at 6" below the diffuser plate ** Static pressure at exhaust collar approximately 0.70" w.g. Model Number SERVICE REQUIREMENTS ELECTRICAL WATER / GASSES REPLACEMENT PARTS (Duplex Outlets are Additional) & OTHER ACCESSORIES HEPA Filter Pleated Pre-filters Lamp T XH - 4 115 V 2.7 Amps 60 HZ consult factory 24" x 48" x 6" (2) - 12" x 24" x 2" (2) - 24", T 8 T ube T XH - 5 115 V 3.8 Amps 60 HZ consult factory 24" x 60" x 6" (2) - 12" x 24" x 2" (2) - 36", T 8 T ube T XH - 6 115 V 3.8 Amps 60 HZ consult factory 24" x 72" x 6" (3) - 12" x 24" x 2" (2) - 48", T 8 T ube T XH - 8 115 V 5.8 Amps 60 HZ consult factory (2) - 24" x 44" x 6" (4) - 12" x 24" x 2" (4) - 36", T 8 T ube

TXH TOTAL EXHAUST HOOD Installation and Operations Manual Revision: 25-Nov-16 Page 11 of 12 16. AIRFLOW DIRECTION When the Total Exhaust Hood is operating, the fans draw lab air into the hood from the top, through the pre-filter and the HEPA/ULPA filter, and then push the cleaned air down to the work surface. Figure 15.1 shows the direction of airflow in the hood. 17. REPLACEMENT PARTS Figure 15.1 Part Pre-filters nominal 12 x 24 x 2 EBM 220 motor Motor capacitor Speed Control TXH-4 HEPA Filter Bead pleat TXH-5 HEPA Filter Bead pleat TXH-6 HEPA Filter Bead pleat TXH-8 HEPA Filter Bead pleat, (quantity 2) TXH-4 ULPA Filter Bead pleat TXH-5 ULPA Filter Bead pleat TXH-6 ULPA Filter Bead pleat TXH-8 ULPA Filter Bead pleat, (quantity 2) For rope replacement consult factory For all plumbing components consult factory for full listings Order Number 10PR0100 17MI0006 17MC0006 (8mf) 17SW0057 10HE0373 10HE0383 10HE0392 10HE0373 10HE0377 Please consult factory for part Please consult factory for part 10HE0377

TXH TOTAL EXHAUST HOOD Installation and Operations Manual Revision: 25-Nov-16 Page 12 of 12 18. WARRANTY Design Filtration Microzone warrants the equipment to be free of defects in materials and workmanship from the date of invoice. The Total Exhaust Hood shall be warranted against defects for a period of three years. Any units or parts found to be defective during this period will be replaced or repaired at our discretion. The buyer agrees to assume all transportation charges prepaid for return of unit to factory for repair. Design Filtration Microzone will not accept charges for removal or re-installation. Design Filtration Microzone will not accept any returned items without prior written consent. Design Filtration Microzone is not responsible for repair or replacement by misuse or abuse by incorrect operating procedures of its equipment. Pre-filters and carbon filters carry no warranty against loading. UV and Fluorescent lights carry no warranty. Any modifications or changes made to equipment by customer without written consent of Design Filtration Microzone will void the warranty. Model number and serial number located on your Total Exhaust Hood must be provided to verify invoice date. Failure to provide will void warranty. FOR FURTHER INFORMATION, PLEASE CONTACT US DIRECTLY. Design Filtration Microzone Inc., 86 Harry Douglas Drive, Ottawa, ON. K2S 2C7 T: 1-888-636-8609 (Canada & USA), T: 1-613-831-8318, F: 1-613-831-8321 info@dfmzgroup.com