ENERGY CONSERVATION IN AUTOMATIC FLUID FLOW CONTROL USING VARIABLE FREQUENCY DRIVE

Similar documents
Introduction to Variable Speed Drives. Pekik Argo Dahono Electrical Energy Conversion Research Laboratory. Institute of Technology Bandung

VARIABLE FREQUENCY DRIVE AND ITS INDUSTRIAL APPLICATIONS

Welcome to basics of drives training module, looking at process control and various control methods. To view the presenter notes as text, please

Up gradation of Overhead Crane using VFD

POWER QUALITY IMPROVEMENT BASED UPQC FOR WIND POWER GENERATION

International Journal of Advance Research in Engineering, Science & Technology

Código de rotor bloqueado Rotor bloqueado, Letra de código. Rotor bloqueado, Letra de código

STACKER/RECLAIMER LONG TRAVEL DRIVE OPERATION WITH VFD - A PERFORMANCE STUDY

International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering. (An ISO 3297: 2007 Certified Organization)

It s What s Inside that Counts

AAFAME Presentation. Shermco Industries Inc. Drives and Automation Application, Sales and Service Manager, Irving Texas.

STUDY ON MAXIMUM POWER EXTRACTION CONTROL FOR PMSG BASED WIND ENERGY CONVERSION SYSTEM

Steve Schouten. Donna Densmore

Reduction of Harmonic Distortion and Power Factor Improvement of BLDC Motor using Boost Converter

Best Practice Variable Speed Pump Systems

Hybrid Motor Technology to Achieve Efficiency Levels Beyond NEMA Premium

Rotor Side Speed Control Methods Using MATLAB/Simulink for Wound Induction Motor

Modeling and Simulation of Five Phase Inverter Fed Im Drive and Three Phase Inverter Fed Im Drive

Effect of prime mover speed on power factor of Grid Connected low capacity Induction Generator (GCIG)

Abstract- A system designed for use as an integrated starter- alternator unit in an automobile is presented in this paper. The

Table of Contents. Foreword...xiii. Chapter One Introduction, Objectives of the Guide...1

Soft Start for 3-Phase-Induction Motor

Real And Reactive Power Saving In Three Phase Induction Machine Using Star-Delta Switching Schemes

Hardware Design of Brushless DC Motor System Based on DSP28335

ECE1750, Spring Motor Drives and Other

Variable Speed Drives Controlling Centrifugal Pumps Energy Savings

ASHRAE - Variable Speed Drives. By Dan Watkins, LEED BD+C Bornquist, Inc.

A Novel Technique for Energy & Cost Effective Drives for AC & DC Motors

ISSN: X Tikrit Journal of Engineering Sciences available online at:

Asynchronous Generators with Dynamic Slip Control

Low Speed Control Enhancement for 3-phase AC Induction Machine by Using Voltage/ Frequency Technique

CONTROL AND PERFORMANCE OF A DOUBLY-FED INDUCTION MACHINE FOR WIND TURBINE SYSTEMS

9. Examples of hydro energy conversion

International Journal of Advance Research in Engineering, Science & Technology

Technical Explanation for Inverters

EXPERIMENTAL VERIFICATION OF INDUCED VOLTAGE SELF- EXCITATION OF A SWITCHED RELUCTANCE GENERATOR

Variable Speed Drives in Electrical Energy Management. Course Content

SPEED CONTROL OF THREE PHASE INDUCTION MACHINE USING MATLAB Maheshwari Prasad 1, Himmat singh 2, Hariom Sharma 3 1

Modelling and Simulation of DFIG based wind energy system

DUAL BRIDGE RECTIFIER FOR PMSG VARIABLE SPEED WIND ENERGY CONVERSION SYSTEMS

Circuit Diagram For Speed Control Of Slip Ring Induction Motor

Variable Frequency Drives

Design and Control of Lab-Scale Variable Speed Wind Turbine Simulator using DFIG. Seung-Ho Song, Ji-Hoon Im, Hyeong-Jin Choi, Tae-Hyeong Kim

DYNAMIC BEHAVIOUR OF SINGLE-PHASE INDUCTION GENERATORS DURING DISCONNECTION AND RECONNECTION TO THE GRID

Principles of iers (intelligent

Using energy storage for modeling a stand-alone wind turbine system

Speed Control of 3-Phase Squirrel Cage Induction Motor by 3-Phase AC Voltage Controller Using SPWM Technique

Energy Savings Variable Frequency Drives and Cooling Tower Fan Motors

AC Adjustable Speed Drives (ASD s)

Combined Input Voltage and Slip Power Control of low power Wind-Driven WoundRotor Induction Generators

Increasing the Battery Life of the PMSG Wind Turbine by Improving Performance of the Hybrid Energy Storage System

Mathematical Modeling and Simulation of Switched Reluctance Motor

PERFORMANCE AND ENHANCEMENT OF Z-SOURCE INVERTER FED BLDC MOTOR USING SLIDING MODE OBSERVER

Performance Analysis of Brushless DC Motor Using Intelligent Controllers and Minimization of Torque Ripples

DESIGN AND ANALYSIS OF CONVERTER FED BRUSHLESS DC (BLDC) MOTOR

Performance Analysis of Bidirectional DC-DC Converter for Electric Vehicle Application

Wind Power Plants with VSC Based STATCOM in PSCAD/EMTDC Environment

Key words: Consumption of Electrical Energy, Slip Ring Induction Motor, Mine Haulers, Rheostatic, Static Control.

G Prasad 1, Venkateswara Reddy M 2, Dr. P V N Prasad 3, Dr. G Tulasi Ram Das 4

A Comparative Performance Analysis DCR and DAR Squirrel Cage 3-Phase Induction Motor

Induction Generator: Excitation & Voltage Regulation

% of Design Input Power (kw)

Control Scheme for Grid Connected WECS Using SEIG

Implementation of FC-TCR for Reactive Power Control

Advance Electronic Load Controller for Micro Hydro Power Plant

A New Control Algorithm for Doubly Fed Induction Motor with Inverters Supplied by a PV and Battery Operating in Constant Torque Region

Design of Control Secheme and Performance Improvement for Multilevel Dc Link Inverter Fed PMBLDC Motor Drive

FAULT ANALYSIS FOR VOLTAGE SOURCE INVERTER DRIVEN INDUCTION MOTOR DRIVE

EE6351 ELECTRIC DRIVES AND CONTROL UNIT-1 INTRODUTION

Comparative Analysis of Integrating WECS with PMSG and DFIG Models connected to Power Grid Pertaining to Different Faults

One-Cycle Average Torque Control of Brushless DC Machine Drive Systems

For motors controlled

Power Flow Management and Control of Hybrid Wind / PV/ Fuel Cell and Battery Power System using Intelligent Control

A Transient Free Novel Control Technique for Reactive Power Compensation using Thyristor Switched Capacitor

Planning and Commissioning Guideline for NORD IE4 Motors with NORD Frequency Inverters

A Dual Stator Winding-Mixed Pole Brushless Synchronous Generator (Design, Performance Analysis & Modeling)

APPLICATION OF VARIABLE FREQUENCY TRANSFORMER (VFT) FOR INTEGRATION OF WIND ENERGY SYSTEM

SPEED AND TORQUE CONTROL OF AN INDUCTION MOTOR WITH ANN BASED DTC

Exercise 6. Three-Phase AC Power Control EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Introduction to three-phase ac power control

Modeling and Simulation of BLDC Motor using MATLAB/SIMULINK Environment

Technical Guide No. 7. Dimensioning of a Drive system

Motors and Variable Speed Drives for Pumps and Fans. Reid Hart, PE

Laboratory Tests, Modeling and the Study of a Small Doubly-Fed Induction Generator (DFIG) in Autonomous and Grid-Connected Scenarios

A Study of the Two Wheeler Retarder Type Dynamometer System

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES UNIT OBJECTIVES 3/21/2012

INVESTIGATION AND PERFORMANCE ANALYSIS OF MULTI INPUT CONVERTER FOR THREE PHASE NON CONVENTIONAL ENERGY SOURCES FOR A THREE PHASE INDUCTION MOTOR

ANFIS CONTROL OF ENERGY CONTROL CENTER FOR DISTRIBUTED WIND AND SOLAR GENERATORS USING MULTI-AGENT SYSTEM

Prepared By: Ahmad Firdaus Bin Ahmad Zaidi

Supercapacitor Based Power Conditioning System for Power Quality Improvement in Industries

CHAPTER 4 MODELING OF PERMANENT MAGNET SYNCHRONOUS GENERATOR BASED WIND ENERGY CONVERSION SYSTEM

International Journal of Advance Research in Engineering, Science & Technology. Comparative Analysis of DTC & FOC of Induction Motor

Modelling and Simulation Analysis of the Brushless DC Motor by using MATLAB

IMPROVING MOTOR SYSTEM EFFICIENCY WITH HIGH EFFICIENCY BELT DRIVE SYSTEMS

Modelling and Analysis of Thyristor Controlled Series Capacitor using Matlab/Simulink

Lab Electrical Power Engineering I

Analysis of Torque and Speed Controller for Five Phase Switched Reluctance Motor

ELECTRONIC SOFT STARTERS. S Gibson

GREE Photovoltaic DC Inverter Centrifugal Chiller

Dynamic Behaviour of Asynchronous Generator In Stand-Alone Mode Under Load Perturbation Using MATLAB/SIMULINK

Starting of Induction Motors

Transcription:

ENERGY CONSERVATION IN AUTOMATIC FLUID FLOW CONTROL USING VARIABLE FREQUENCY DRIVE Mr. Pinkle J. Bhatt 1, Prof. Aditi R. Hajari 2 1 PG Student, Electrical Engineering Department, SCET, Surat,( India) 2 Associate Professor, Electrical Engineering Department SCET, Surat, (India) ABSTRACT The Pumping systems account for nearly 20% of the world s electrical energy demand and range from 25-50% of the energy usage in certain industrial plant operations Pumping systems consume a significant portion of the electricity. Actual energy savings will vary greatly depending on how the discharge pressure of the constant speed pump is controlled and how it is operated after the VFD is installed. In the present work, the flow of pump has been controlled by two different methods, simulation work has been carried out and comparative statement is given. In this paper MATLAB simulink is use to show the performance of energy conservation in automatic fluid flow control using VFD. Keywords: Energy Conservation, Pulse Width Modulation, Matlab, Variable Frequency Drive, Variable Voltage Variable Frequency Drive I. INTRODUCTION Pumps are used widely in industry to provide cooling and lubrication services, to transfer fluids for processing, and to provide the motive force in hydraulic systems. Pumping systems account for nearly 20% of the world s electrical energy demand and range from 25-50% of the energy usage in certain industrial plant operations [1]. With raising energy costs, process plants are increasing their focus on the amount of energy consumed by rotating equipment. An improperly sized or poorly performing pump consumes unnecessary money. The performance curves for a pump are shown in figure1, which are some important characteristics used for the design,modification, selection and performance assessment..figure.1 Basic criteria for selecting a pump are Head-Flow requirement and pump size. Pump efficiency varies with flow rate and head and it is highest at one point only, which is called best efficiency point. A pump is selected on the basis that pump curve and system head flow curve should be matched and pump is operated on the desired operating point. 53 P a g e

Figure 1 Pump Performance Characteristics An over-sized pump is derated by the various methods such as: Throttling Variable speed drive Impeller trimming Bypass control. Suppose consider a system having a system curve as shown in figure 2 by line SC1. The pump curve is line PC1 which intersect system curve at operating point A, where the flow rate is 700m3/hr and head is 40 meter. But,the actual requirement of flow is 400m3/hr. Hence the flow rate can be reduced by closing the throttle valve which inserts the artificial resistance to the system and system curve is lifted over the first one. The new operating point becomes B at which desired flow rate 400m3/hr is achieved but at higher head. Hence, pump has to overcome additional head (BC) and for that pump consumes more electrical power. Thus by throttling valve operation to control flow rate is not efficient method. The another best option is to reduce the speed form N1 to N2 hence pump curve is shifted below and intersect original system curve at point C, which is the best efficiency point (BEP) for the pump where desired flow and head are achieved and also the overall efficiency figure 2 Flow control methods II. BENEFITS OF VFD 54 P a g e

The use of variable frequency drive control offers several advantages. The most significant benefit is its potential to reduce electrical energy consumption and demand from motor-driven processes. Figure 3 Comparison between power and flow for different fan control types Figure 3 above compares the relative power requirements of a fan at different flow rates, using three types of throttling control: outlet damper control, variable inlet vane control, and VFD control. Although VFDs save far more energy than throttling, the technology has not yet achieved widespread adoption. According to the Bonneville Power Administration, throttling continues as one of the most common and inefficient methods to control a fan or pump. Variable frequency drives also have the potential to reduce system maintenance and related costs. Control with a VFD affords the capability to soft start a motor, which means the motor, can be brought up to its running speed slowly rather than abruptly starting and stopping. Similarly, running the motor at lower speeds extends the lifetime of other equipment components, including shafts and bearings. In addition to enabling precise speed control of applications such as conveyors or winders, other parameters such as pressure, flow and even temperature may be accurately controlled. The efficiency of the electrical supply is increased and more of the electrical current drawn is used to drive the load. Hence the implementation of VFD improves the power factor of the system. In addition to this VFD provides good dynamic response. This can be achieved by rapid adjustment of speed, torque and power and hence gives better control in high speed applications. In some applications it is also possible to operate motors at higher speeds than their nominal speeds. The other advantage of VFD is that it is possible to interface VFDs to wider process control systems such as supervisory control, data acquisition (SCADA) systems and building management systems (BMS) Programmable Logic Controller (PLC).Hence VFD is able to compute intelligence and communication systems. III. VFDS OPERATION AND ENERGY SAVING PRINCIPLES 55 P a g e

A VFD can reduce energy consumption of a motor by as much as 60%. This is due to the fact that they control the speed of the motor by altering the frequency and therefore the power supplied to it. Even a small reduction in the rotational speed can give significant saving in the energy consumed by the motor. In order to do so we take a closer look to the so called affinity laws which are used in hydraulics to express relationships between the variables involved in the operation and performance of rotary machines such as pumps and fans. Most HVAC equipment is designed to perform during peak loads. These loads occur rarely during the operating year. To control flow during off-max load conditions, flow control devices such as dampers, valves, inlet guide vanes and bypass systems are used.these throttling devices are effective, but not energy efficient. Using variable frequency drives (VFD) varies the speed of fans and pumps, referred to as the affinity laws, allows the equipment to meet the partial load requirement and save energy. Affinity Laws are used in hydraulic and HVAC system to express the relation between several variables involved in pump and fan performance such as (such as, shaft speed, and power). They apply to pumps, fans, and hydraulic turbines. Flow is directly proportional to speed; Q2/Q1 = N2/N1 Torque required is proportional to speed squared; T2/T1 = (N2/N1)² Power is proportional to the cube of the shaft speed; P2/P1 = (N2/N1)³ IV. HOW DOES A VFD WORK? As we know, the induction motors are the workhorse of industry, which will rotate at a fixed speed that is determined by the frequency of the supply voltage. Alternating current applied to the stator windings produces a magnetic field that rotates at synchronous speed. This speed may be calculated by dividing line frequency by the number of magnetic pole pairs in the motor winding. A four-pole motor, for example, has two pole pairs, and therefore the magnetic field will rotate 60 Hz / 2 = 30 revolutions per second, or 1800 rpm. The rotor of an induction motor will attempt to follow this rotating magnetic field, and, under load, the rotor speed "slips" slightly behind the rotating field. This small slip speed generates an induced current, and the resulting magnetic field in the rotor produces torque. Since an induction motor rotates near synchronous speed, the most effective and energy-efficient way to change the motor speed is to change the frequency of the applied voltage. VFDs convert the fixed-frequency supply voltage to a continuously variable frequency, thereby allowing adjustable motor speed. A VFD converts 50 Hz power, for example, to a new frequency in two stages: the rectifier stage and the inverter stage. The conversion process incorporates three functions: 56 P a g e

Rectifier stage: A full-wave, solid-state rectifier convert three- phase 50 Hz power from a standard 208, 460, 575 or higher utility supply to either fixed or adjustable DC voltage. The system may include transformers if higher supply voltages are used. Inverter stage: Electronic switches - power transistors or thyristors - switch the rectified DC on and off, and produce a current or voltage waveform at the desired new frequency. The amount of distortion depends on the design of the inverter and filter. Control system: An electronic circuit receives feedback information from the driven motor and adjusts the output voltage or frequency to the selected values. Usually the output voltage is regulated to produce a constant ratio of voltage to frequency (V/Hz). Controllers may incorporate many complex control functions. Converting DC to variable frequency AC is accomplished using an inverter. Most currently available inverters use pulse width modulation (PWM) because the output current waveform closely approximates a sine wave Figure 4 VFD operated motor The advantages of VFD in addition to energy saving are: 1 Improved process control because VSDs can correct small variations in flow more quickly. 2 Improved system reliability because wear of pumps, bearings and seals is reduced. 3 Reduction of capital & maintenance cost because control valves, by-pass lines, and conventional starters are no longer needed. 4 Soft starter capability: VSDs allow the motor the motor to have a lower startup current. 57 P a g e

V. SIMULATION & SIMULATION RESULTS Figure 5 Simulation Model of Direct mode of supply to 5 hp Induction motor and measurement of Energy. Figure 6 Rotor current response without VFD Figure 7 Stator current response without VFD 58 P a g e

Figure 8 Rotor Speed Waveform without VFD Figure 9 Torque Waveform without VFD Figure 10 Simulation Model of Indirect mode of supply to Induction motor and measurement of Energy. 59 P a g e

Figure 11 Rotor current response with VFD Figure 12 Stator current response with VFD Figure 13 Rotor Speed Waveform with VFD Figure 14 Torque Waveform with VFD 60 P a g e

Table 1 Comparison Between with & without VFD in pumping system Figure 15 Energy Saving Band With & without VFD From the above comparison table 1 we can clearly see that approximately 30% of energy saving is done after installation of VFD in pumping system. 61 P a g e

From the figure 15 we can see that the saving of energy with and without VFD with the use of energy saving band. The energy saving band gives the clearly idea that how much electrical energy is save after installation of VFD. VI. CONCLUSION As by control the flow of pump with throttling (direct mode), net head increases and to overcome this extra head motor draw extra power. VFD offers a very good response to pumping system. Reduces the flow with VFD, motor consume very less power. So significant amount of power can be saved with the help of Variable Frequency Drive. VFD also serves as Soft Starter, during starting motor draws 6 times more current than rated current. While starting with VFD, motor draws very less current and also provide a smooth stopping of motor. So the losses occur in motor can be eliminated. Thus we can conclude that Variable frequency drives (VFD s) are often recommended as a way to save pumping energy and it will help for conservation of electrical energy for our future generation. REFERENCES [1] Joseph R.Pottebaum, "Optimal Characteristics of a Variable-Frequency Centrifugal Pump Motor Drive IEEE transactions on industry applications, vol. ia-20, no. 1, January 1984 [2] Xiaodong Liang, Obinna Ilochonwu, Rotimi Adedun " Dynamic Response of Variable Frequency Drives in Electrical Submersible Pump Systems IEEE Industrial & Commercial Power Systems Technical Conference (I&CPS), IEEE/IAS 48th 2012. [3] Slobodan A. Mircevski, Zvonimir.A. Kostic, Z. Lj. Andonov Energy Saving With Pump's Ac Adjustable Speed Drives IEEE Electrotechnical Conference, MELECON 98., 9th Mediterranean (Volume:2 ) 1998. [4] Walter V. Jones Motor Selection For Centrifugal Pump Applications Made Easy Annual IEEE Pulp and Paper Industry Technical Conference (PPIC), Conference Record of 2011. [5] Mr.Priyank Dave, Mr.Kashyap Mokariya, Mr.Vijay Patel Energy Conservation In Centrifugal Pump With Variable Frequency Drive Including SCADA, PLC and HMI. International Journal of Innovative Research in Science (IJIRSET), Engineering and Technology Vol. 2, Issue 5, May 2013. [6] Herbert W.Weiss, Adjustable Speed AC Drive Systems for Pump and Compressor Applications IEEE Transactions on Industry applications, vol. Ia-10, no. 1, january 1974 [7] Dennis A.Jarc, Dennis P.Connors, Variable Frequency Drives and Power Factor IEEE Transactions On Industry Applications, Vol. Ia-21, No. 4, May/June 1985 [8] Frank A. Dewinter, Brian J.Kedrosky The Application of a 3500-hp Variable Frequency Drive for Pipeline Pump Control IEEE Transactions On Industry Applications, Vol. 25, No. 6, November december 1989 [9] Peter W.Hammond,"A Universal Controller for Parallel Pumps with Variable Frequency Drives" IEEE Transactions On Industry Applications, Vol. Ia-20, No. 1, January 1984 [10] Neetha John, Mohandas R, Suja C Rajappan. Energy Saving Mechanism Using Variable Frequency Drives International Journal of Emerging Technology and Advanced Engineering Volume 3, Issue 3, March 2013 62 P a g e