Page : 1 of 16. FIELD OF TESTING : Calibration and Measurement CALIBRATION & MEASUREMENT CAPABILITY EXPRESSED AS AN UNCERTAINITY *

Similar documents
CERTIFICATE OF ACCREDITATION

Calitron Calibration Laboratory, U1: 207, Kohinoor Arcade, Tilak Chowk, Nigdi, Pune, Maharashtra

Alcalab Private Limited, 3rd Floor, Ashiana Trade Centre, Adityapur, Jamshedpur, Jharkhand. Discipline Mechanical Calibration Issue Date

Cal-Tech Calibration Services Pvt. Ltd., Flat No.8, Avadhut Heights, Anand Nagar, Sinhgad Road, Pune, Maharashtra

Schedule. 300 mm to 600 mm 600 mm to 1000 mm inch to 12 inch

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Hi-Tech Calibration, 307, 3rd Floor, Govinda Complex, Char Rasta, Vapi, Gujarat. Discipline Mechanical Calibration Issue Date

Discipline Mechanical Calibration Issue Date Certificate Number C-0752 Valid Until Last Amended on - Page 1 of 6

Welcome to Garber C O R P O R AT E O V E R V I E W

Certificate of Accreditation

Discipline Mechanical Calibration Issue Date Certificate Number C-0393 Valid Until Last Amended on - Page 1 of 6

Accurate Labs, 311, 312 Govinda Complex, GIDC Char Rasta, Vapi, Valsad, Gujarat. Discipline Mechanical Calibration Issue Date

Certificate of Accreditation

Discipline Mechanical Calibration Issue Date Certificate Number C-0208 Valid Until Last Amended on

Certificate of Accreditation

QA Tech (A Division of GMP Technical Solutions Pvt. Ltd.), L-73, Verna Industrial Estate, Verna Salcette, Goa

Certificate of Accreditation

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017. Data Weighing Systems 255 Mittel Drive Wood Dale, IL Steven A. Thomas CALIBRATION

Accurate Measurements, Plot No.103, D Block, Meethapur Ext., Badarpur, New Delhi. Discipline Mechanical Calibration Issue Date

Q-Tech Engineering Services, S-134, C/o, Precision Engineering Works, MIDC, Bhosari, Pune, Maharashtra

A.A. Calibration Pvt. Ltd., 13-C/18, Vasundhara Haat, Vasundhara, Ghaziabad, Uttar Pradesh. Discipline Mechanical Calibration Issue Date

Caliber Gauges & Instruments Laboratory, S. No. 14/1, Dattadigamber Soc. B, Warje Jakat Naka, Pune, Maharashtra

Discipline Mechanical Calibration Issue Date Certificate Number C-0751 Valid Until Last Amended on

Height Master Page 345. Check Master Page 349. Calibration Tools Page 354

Institute for Design of Electrical Measuring Instruments, Swatantryaveer Tatya Tope Marg, Chunabhatti, Sion, Mumbai, Maharashtra

ICL Calibration And Testing Services, SCO - 37, Ground Floor, Sector-12, Panchkula, Haryana. Discipline Mechanical Calibration Issue Date

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Scope of Accreditation For Global Instrumentation Services, LLC 523 N. Sam Houston Parkway E, Suite 230 Houston, TX Gavin Lewis

CALIBRATION SYSTEM CERTIFICATE

Rev /07/2015 CATALOGUE - CALIBRATION SERVICES 1

Central Mechanical Engineering Research Institute, Mahatma Gandhi Avenue, Durgapur, West Bengal

Schedule. 200 C to 400 C. 400 C to 660 C C to 800 C C to 1300 C C to 1200 C. 0 C to 1700 C. 0 C to 1700 C.

CERTIFICATE OF ACCREDITATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Accredited Laboratory

TEST AND CALIBRATION SERVICES Ensuring quality and reliability.

Autocal Solutions Pvt. Ltd., Plot No. BG-74, Gala No. 1 & 2, Jai Tulja Bhavani Indl. Premises, Telco Road, MIDC Bhosari, Pune, Maharashtra

Certificate of Accreditation

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF FORCE METROLOGY:- CALIBRATION OF UNIAXIAL TESTING MACHINES

Page 1 of 5. United Testing Systems, Inc S. Acacia Avenue Fullerton, CA William Warner, Quality Manager

Certificate of Accreditation

Price List. Calibration Fee

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005


Small Tool Instruments and Data Management

Shawal CGC Calibration Profile

TRI-STATE INSTRUMENT SVC, INC

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Re: Extension for ISO/IEC 17025: 2005 accreditation Certificates #ACT-1997, ACT , ACT & AT

Metrology Laboratory, CMTI, Central Manufacturing Technology Institute, Tumkur Road, Bangalore, Karnataka Accreditation Standard ISO/IEC 17025: 2005

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Certificate of Accreditation

SCOPE OF ACCREDITATION TO ISO/IEC & KS Q ISO/IEC

Shriram Institute For Industrial Research, 14-15, Sadarmangala Industrial Area, Whitefield Road, Bangalore, Karnataka

0280 / 0281 Vernier depth gauges

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TORQUE METROLOGY (Torque Generating Device Calibration)

Small Tool Instruments and Data Management

Certificate of Accreditation

Certificate of Accreditation

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Ref:CL/Mech./ Cal /BID-01(13-14) Date: 10 July 2013

Hellenic Accreditation System. Annex F2/17 to the Certificate No SCOPE of ACCREDITATION

CALIBRATION PRICE LIST

PROMPT ENGINEERING P.O. BOX BARWA VILLAGE, WAKRA, BUILDING NO. 6 SHOP NO. 19 AND 20 DOHA QATAR

Calibration Schedule and Tolerances

TORQUE BARS TORQUE WRENCHES PRE-TORQUE WRENCHES DIGITAL TORQUE WRENCHES. 1/4 dr. torque tools. Torque bars, 9x12mm. 3/8 dr.

Check Points. for Measuring Instruments

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

CHAPTER 4 VARIABLE COMPRESSION RATIO ENGINE WITH DATA ACQUISITION SYSTEM

Measuring. Affordable. Effective. Instruments

YOUR MITUTOYO PROMOTION


Certificate of Accreditation

ISO 376 INTERNATIONAL STANDARD. Metallic materials Calibration of force-proving instruments used for the verification of uniaxial testing machines

Standard Calibration Certificate

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Standard Calibration Certificate

ASTM E74-13a Explained

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

L éditorial. Robert Renaud

SPECIFICATION SHEET Pulse tool / Impact Wrench Testing System MODEL : IWT-101

Standard Scales SERIES 182 Made of Low-Expansion Glass. Working Standard Scales SERIES 182 E-32

... CALIBRATION SERVICES PRICELIST. M&B Calibr. Accredited calibration company. No according to ČSN EN ISO/IEC

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. SCHAP LABORATORY SERVICES, LLC Taft Road, Unit 5 Spring Lake, MI Erik Johnson Phone:

REQUEST FOR QUOTATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Verifying the accuracy of involute gear measuring machines R.C. Frazer and J. Hu Design Unit, Stephenson Building, University ofnewcastle upon Tyne,

What is the secret to our success?

The FMM force tester can be controlled using L1 software for limit, cycling, hold and coefficient of friction testing.

New. Swiss Promo. Shop Proof Technology. TESA-HITE Magna 400 and TESA-Cal. Validity : All prices with VAT excluded

Small Tool Instruments and Data Management

System 8. Digital Torque Tester. Our most accurate digital torque tester with Fail Safe Engineering! Page 48 Sturtevant Richmont

JJG Translated English of Chinese Standard: JJG Wayne Zheng et. al

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Morehouse Instrument Company

0268 Gear tooth calipers

Transcription:

Metrix Precision Pte Ltd Certificate No. : LA-2014-0581-C No. 23 Tagore Lane #02-03/04 Tagore 23 Warehouse Issue No. : 2 Singapore 787601 Date : 29 July 2016 FIELD OF TESTING : Calibration and Measurement Page : 1 of 16 CAPABILITY EXPRESSED AS A. Dimensional Metrology 1. Geometrical Measurement i. Flatness measurement In-house calibration Optical Parallel (Dia 12 mm) MP-DIM-01(T) 0.3 m Dial Test Indicator (Up to 100 mm) 3.0 m (101 to 500 mm) 3.0 m (Up to 1000 mm) 3.0 m ii. Parallelism & Straightness In-house calibration measurement Section MP-DIM-01(T) Dial Test Indicator (Up to 100 mm ) 3.0 m (101 to 1000mm) 3.0 m Mu-Checker System (Up to 100 mm) 0.4 m (101 to 1000 mm) 0.4 m

Date : 29 July 2016 Page : 2 of 16 iii Angle measurement In-house calibration 0.18 Optical Comparator Protractor Up to 360 º Procedure MP-DIM-01(T) (Minute) 2. Limit Gauges (Lab) i. Plain Plug Gauges or Pin Gauges In-house calibration Up to 25 mm Section 0.7 m MP-DIM-10(T) V2R1 ii. Plain Ring Gauges Up to 50 mm 2.4 m 50 to 225 mm 5.0 m 3 Micrometer Gauges i. External Micrometer and In-house calibration Interchangeable micrometer Section (Analog & Digimatic) MP-DIM-02(T) Resolution (0.001 mm) 0 to 25 mm 1.0 m 26 to 50 mm 1.0 m 51 to 75 mm 1.0 m 76 to 100 mm 1.0 m 101 to 200mm 1.0 m 201 to 400mm 1.0 m 401 to 600mm 2.0 m 601 to 800 mm 3.0 m 801 to 1000mm 3.0 m

Date : 29 July 2016 Page : 3 of 16 CAPABILITY EXPRESSED AS ii. Internal Micrometer In-house calibration Section 5 to 30 mm MP-DIM-02(T) 1.0 m 25 to 50 mm 1.0 m 50 to 75 mm 1.0 m 75 to 100 mm 1.0 m iii Stick Micrometer In-house calibration (Analog and Digimatic) Section MP-DIM-02(T) 50 to 63 mm 2.0 m 13 to 100 mm 2.0 m 100 to 200 mm 2.0 m 200 to 300 mm 2.0 m iv Depth Micrometer In-house calibration Section 0 to 25 mm MP-DIM-02(T) 2.0 m 25 to 300 mm 2.0 m vi Micrometer Head In-house calibration 2.0 m 0 to 25 mm Section 2.0 m 0 to 50 mm MP-DIM-02(T) Holtest Micrometer up to 5 0.00012 inches

Date : 29 July 2016 Page : 4 of 16 4 Caliper i. Slider Caliper In-house calibration. 0 to 150 mm MP-DIM-03(T) 10.0 m 0 to 200 mm 10.0 m 0 to 300 mm 10.0 m 0 to 600 mm 10.0 m 0 to 1000 mm 10.0 m ii. iii. Depth Caliper In-house calibration. MP-DIM-03(T) 0 to 150 mm 10.0 m 0 to 200 mm 0 to 300 mm Caliper Gauges Internal, External and Thickness Type (Dial and Digimatic) 10.0 m 10.0 m 0 to 60 mm 10.0 m 60 to 70 mm 10.0 m 70 to 135 mm 10.0 m 5 Height Gauge Instrument In-house calibration. MP-DIM-04(T) i. Height Gauge (Resolution 0.001 mm) 0 to 300 mm 0 to 600mm 1.0 m 1.0 m

Date : 29 July 2016 Page : 5 of 16 6 Dial and Level Type Instrument In-house calibration. MP-DIM-05(T) i. Dial Gauges/ Indicator Dial Test Indicator Lever Probe Indicator Micro Indicator 0 to 5 mm 0 to 10 mm 0 to 30 mm 0 to 50 mm (Resolution 0.001 mm) (Graduation 0.001 & 0.01 mm) 0.5 m 0.7 m 0.8 m 1.2 m 7. Linear and Indicating Instrument (Lab) Linear Gauges Linear Transducer Digimatic Indicator Indicating Gauge 0 to 12 mm (Resolution 0.001mm) 0 to 30 mm (Resolution 0.0005mm) 0 to 50 mm (Resolution 0.001mm) 0.6 m 0.3 m 0.6 m

Date : 29 July 2016 Page : 6 of 16 8. End Standard i. End Standard length measurement (Extension Rods, Standard Rods) Using DTI System In-house calibration. MP-DIM-07(T) Up to 25 mm 2.0 m 25 to 50 mm 2.0 m 50 to 75 mm 2.0 m 75 to 100 mm 2.0 m 100 to 200mm 2.0 m 200 to 400 mm 2.0 m 400 to 600mm 3.0 m 600 to 800 mm 4.0 m 800 to 1000 mm 5.0 m ii Using Mu-checker System (Lab) Up to 25 mm In-house calibration 2.0 m 25 to 50 mm. 2.0 m 51 to 75 mm MP-DIM-07(T) 2.0 m 76 to 100 mm 2.0 m 101 to 200 mm 2.0 m 201 to 400 mm 2.0 m 401 to 600 mm 3.0 m 601 to 800 mm 4.0 m 801 to 1000 mm 5.0 m

Date : 29 July 2016 Page : 7 of 16 9. Line Standard i Steel Rule In-house calibration Plastic Rule Procedure. MP-DIM-08(T) Length Accuracy 0.058 mm - Up to 200 mm 0.058 mm - Up to 400 mm 0.058 mm - Up to 600 mm 0.058 mm - Up to 800 mm 0.058 mm - Up to 1000 mm 0.058 mm ii Measuring Tape In-house calibration Measuring Tape MP-DIM-08(T) Hermatic Ullage Tape Tank Gauging Tape Hook Tape Surveyor Tape (Lab) - Up to 10 m 0.0004 m - Up to 30m 0.0006 m - Up to 50 m 0.0008 m - Up to 100m 0.0010 m iii Glass Scale (Including Stage Micrometer Scale, Microscope Glass Scale and other Related scale) In-house calibration. MP-DIM-08(T) Length Accuracy - Up to 200 mm 0.005 mm

Date : 29 July 2016 Page : 8 of 16 10 Parallel Screw Gauges In-house calibration Thread Plug Procedure - External and Internal Thread MP-DIM-15(T) Up to 80 mm V2R1 - Pitch Diameter 2 m - Major Diameter 2 m - Pitch Distance 5 m - Angle 0.15 minutes Thread Ring Up to 80 mm - Pitch Diameter - Minor Diameter 4 m 5 m 11 Cylinder Gauges including Bore In-house calibration (Lab) Gauges. - Length Accuracy MP-DIM-16(T) Up to 450 mm 1 m 12. Measurement if Die Crimping Tool In-house calibration Hand Crimp Tools 12 m MP-DIM-20(T) 13. Profile Projector & Toolmaker Microscope In-house calibration Up to 200 mm MP-DIM-14(T) V2R1 4 m

Date : 29 July 2016 Page : 9 of 16 14. Gauge Block ( Same Material) In-house calibration 0.1 to 10 mm MP-DIM-25(T) 1.0 m 10 to 25 mm 1.0 m 25 to 50 mm 1.0 m 50 to 75 mm 1.0 m 75 to 100 mm 1.0 m B. Mechanical Metrology 1. Torque Measuring Devices In-house calibration Setting Torque Tool MP-MEC-01(T) Dial Torque Tool Torque Wrench Torque Screw Diver Torque Gauge Digital Torque Gauge - 0.5 to 1.5 N.m 0.01 N.m - 1.5 to 6 N.m 0.05 N.m - 6 to 30 N.m 0.23 N.m - 30 to 60 N.m 0.22 N.m - 60 to 100 N.m 0.22 N.m - 100 to 300 N.m 2.4 N.m - 300 to 850 N.m 2.4 N.m - 850 to 1400 N.m 2.6 N.m - 1400 to 2000 N.m 5.0 N.m

Date : 29 July 2016 Page : 10 of 16 2. Balance and Weighing Scales In-house calibration MP-MEC-02(T) Electronic Balance Analytical Balance Weighing Scales - up to 0.500 g - Off center error 0.000063 g - up to 210 g - Hysterisis 0.00016 g - up to 1000 g - Repeatability 0.0067 g - up to 5000 g - Linearity 0.071 g - up to 15kg 0.000058 kg - up to 60kg 0.0058 kg - up to 300kg 0.029 kg 3. Force Measuring Devices In-house calibration. Section 3.0 MP-MEC-03(T) Push Pull Gauge Force Gauge Torque Meter Cable Tension Meter Load-cell / Load Indicator Load Gauge Spring Balance Tension Meter Pull Tester Push Tester

Date : 29 July 2016 Page : 11 of 16 MEASURED QUANTITIES/ RANGE/ INSTRUMENT TO BE CALIBRATED Tension Gauge Tensile Tester Shear Tester Force Indicator/ Gauge Dynamometer Belt Tension Gauge Strap Tension Gauge Wire Tension Meter - Up to 5 kgf 0.00058 kgf - Up to 10 kgf 0.0058 kgf - Up to 20 kgf 0.0058 kgf - Up to 50 kgf 0.0058 kgf - Up to 120 kgf 0.0058 kgf Load Cell - Up to 100 kn (Ref UTM) 0.57 kn Dial Tension Gauge In-house calibration Tension Gauge Spring Balance MP-MEC-03(T) Load Cell Cable Tension Meter Strain Gauge Pull Tester Tubular Balance Push Tester Force Gauge Load Gauge Gram Gauge Tensile Tester Shear Tester Force Indicator

Date : 29 July 2016 Page : 12 of 16 MEASURED QUANTITIES/ RANGE/ INSTRUMENT TO BE CALIBRATED - Up to 50 gf 0.23 gf - Up to 100 gf 0. 23 gf - Up to 250 gf 1.2 gf - Up to 1000 gf 2.3 gf - Up to 2000 gf 12 gf 4. Torque Meter Tester In-house calibration MP-MEC-04(T) Torque Checker Torque Analyser Torque Tester Digital Torque Meter Torque Transducer Torque Indicator - Up to 5 N.m 0.0059 N.m - Up to 10 N.m 0.0058 N.m 5. Torque Measuring Devices Torque Multiplier System MP-MEC-09(T) Torque Multiplier - Up to 1200 lbf ft 3.7 lbf ft - Up to 3200 lbf ft 8.5 lbf ft - Up to 5000 lbf ft 15 lbf ft

Date : 29 July 2016 Page : 13 of 16 MEASURED QUANTITIES/ RANGE/ INSTRUMENT TO BE CALIBRATED 6. Rubber Hardness Tester In-house calibration MP-MEC-05(T) Shore A,B, E & O Hand Durometer Pencil Durometer Digital Durometer Tire Hardness Gauge Pocket Durometer Dial Durometer Direct Force Verification - Up to 75 Div (855 gf) 12 mn 7. Hardness Machine In-house calibration In-direct verification method of hardness machine (C & B) Hardness Tester Impressor Tester Digital Hardness Tester Handheld Hardness Tester Analogue Tester Brinell Hardness Tester Portable Hardness Machine MP-MEC-06(T) HRC BLOCK - 20 to 30 0.39 HRC - 40 to 45 0.34 HRC - 60 to 65 0.33 HRC

Date : 29 July 2016 Page : 14 of 16 MEASURED QUANTITIES/ RANGE/ INSTRUMENT TO BE CALIBRATED HRB BLOCK - 50 to 60 1.0 HRB - 60 to 65 1.3 HRB - 80 to 90 1.5 HRB 8. Tachometer Non-Contact In-house calibration MP-MEC-07(T) Optical Tachometer Infrared Tachometer Laser Tachometer Mechanical Tachometer RPM Indicator Revolution Indicator Digital Tachometer Speed Indicator Speed Meter - 0 to 300 rpm 0.28 rpm - 300 to 600 rpm 0.28 rpm - 600 to 1200 rpm 0.29 rpm - 1200 to 2000 rpm 0.28 rpm - 2000 to 5000 rpm 0.28 rpm - 5000 to 10000 rpm 1.9 rpm - 10000 to 20000 rpm 1.9 rpm - 20000 to 50000 rpm 1.9 rpm - 50000 to 70000 rpm 16 rpm - 70000 to 90000 rpm 16 rpm

Date : 29 July 2016 Page : 15 of 16 MEASURED QUANTITIES/ RANGE/ INSTRUMENT TO BE CALIBRATED 9 Contact Tachometer (Lab/Site) In-house calibration MP-MEC-07(T) 250 to 500 rpm 0.15 rpm 500 to 1000 rpm 0.31 rpm 1000 to 2000 rpm 0.33 rpm 2000 to 5000 rpm 0.33 rpm 5000 to 9600 rpm 0.61 rpm 10 Pressure Measuring Devices, In-house calibration Hydraulic (Lab/Site) Pressure Gauge Oil Pressure Gauge Force Pressure Gauges Pressure Transmitters Pressure Recorders Pressure Indicators Vacuum Gauge Air Gauge Transducer Transmitters Recorders MP-MEC-11(T) V2R1 - -13.5 psi to 30 psi 0.015 psi - Up to 300 psi 0.062 psi - Up to 1000 psi 0.21 psi - Up to 5000 psi 1.0 psi - Up to 10000 psi 2.1 psi - Up to 15000 psi 3.1 psi CMC is expressed as an expanded uncertainty estimated at a level of confidence of approximately 95%.

Date : 29 July 2016 Page : 16 of 16 Approved signatories Mr M. Karunanithi Mr Surendren A/L R Palpanadan - All items - All items Note : This laboratory is accredited in accordance with the recognised International Standard ISO/IEC 17025:2005. A laboratory's fulfilment of the requirements of ISO/IEC 17025:2005 means the laboratory meets both the technical competence requirements and management system requirements that are necessary for it to consistently deliver technically valid calibration results. The management system requirements In ISO/IEC 17025:2005 (Section 4) are written in language relevant to laboratory operations and meet the principles of ISO 9001:2008 Quality Management Systems Requirements and are aligned with its pertinent requirements.