Technical Information. A U R O R A Konrad G. Schulz GmbH & Co. KG Tel.: /

Similar documents
Elektr. Thermostat HCC, 12/24V (Heating and Cooling Controller)

Instruction Manual. Sewage lifting station compli 300

Starting up hydraulic systems

Instruction Manual. Automatic Fuel Oil De-aerator Flow-Control. Flow-Control 3/K-1 # Flow-Control 3/K-2 # 70019

Inhalt. Granule jet blasting device PG 5 8. Owner s Manual. Translation of the original instructions

INSTRUCTION MANUAL MAGNA RAIL

Rotary feed-through DDF-S/-KS

Replacing safety battery terminal (SBK)

Industrial flue gas probes. Instruction manual

Operating Instructions for Elevator Buffers type LP

Volkswagen Golf > VW Rabbit GTI 2006-> (A5)

RA / Internal Gear Pump Model GP2, Series 2X Fixed Displacement. Typical application:

Pneumatic Axial Fan Type Tech. Doc. No. 802

Trouble Shooting Guide EWA, 3-phase (D2422)

original operating manual Operating manual Translation of the Item-No.: ,

AR27.00-P-0100AC Check oil level in automatic transmission and correct if necessary TRANSMISSION 722.6

ALWAYS follow all Webasto installation and repair instructions and observe all warnings.

Pressure chlorine changeover unit C 7520

RA / Internal Gear Pump Model GP3, Series 3X Fixed Displacement. Typical application:

OPERATING INSTRUCTIONS Thread unscrewing unit Z 5410, Z5420, Z5430

Active Controlled Cooling System

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

A/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES

ALWAYS follow all Webasto installation and repair instructions and observe all warning instructions.

OPERATING MANUAL LA-BO. Applicator

! C A U T I O N! Damages on the machine possible.

EasySelect-Cup Manual Powder Gun

Wiring diagrams on page 29 are for reference only. For detailed vehicle wiring refer to Navistar documents.

ALWAYS follow all Webasto installation and repair instructions and observe all warnings.

HPD Hydraulic Post Driver

ALWAYS follow all Webasto installation and repair instructions and observe all warnings.

ALWAYS follow all Webasto installation and repair instructions and observe all warnings.

EASY!Force trigger gun, rotary knob, spray lance, PowerControl spray lance Service Manual

1 Engine and peripherals

Pump drives. Operator s manual C

RADIATOR CLEANING OF RADIATOR

Operating Instruction Manual of Energy Management System EBL 208, Art.-No Seite 1 / 7

RADEX -N Composite Operating/Assembly instructions

DIAGNOSIS AND TESTING

T Series (N6052T) Solar Battery Hybrid System. Installation Manual Version 1.1

CRS-D Powder Coating Booth with Reverse Jet Cleaning System

MANN+HUMMEL ENTARON XD. Installation and Maintenance Manual. Version 0709

Operating instructions Rotary actuators M135 M140 M150 M180. June 2012 / / EN

Axial Piston Fixed Pump A17FNO Series 10

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

DIAGNOSIS MADE EASY PART OF COOLING SYSTEM TROUBLE SHOOTING

BoWex FLE-PA. BoWex FLE-PAC. KTR-N Sheet: Edition: EN 1 of BoWex FLE-PA / FLE-PAC Operating/Assembly instructions

PURE SINE WAVE DC TO AC POWER INVERTER

GRUNDFOS INSTRUCTIONS MTC. Installation and operating instructions

TA-05/C. Instruction and Operation Manual. valid for art.-no.: F-TA-05/C-ISO. (start at modification No. 1601)

200-SERIES EXTRACTION

Swing Piston Compressors and Vacuum Pumps

INSTRUCTION MANUAL ANGLE GRINDER PT W

EPS/ELA-Series User Manual EPS/ELA 250W

Remedy: Use a PC, check the accuracy of the signal, check external temperature sensor, check the wiring, check the connectors.

HH10/HH10RV Hydraulic Breaker

FF 20 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS

Type 3320, Service Manual. Serviceanleitung Service Manuel

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

Supplementary instructions. Air cooling - FIBERTRAC 31. Active air cooling system for radiation-based sensors. Document ID: 50339

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1969 CHEVROLET CAMARO/ FIREBIRD NOTE: INSTRUCTIONS DEPICT CAMARO

Battery Charger. Series EASY Charger. User s manual

Operating Instructions Bedienungsanleitung Mode d emploi EWB EWB

Type 2000, 2002, 2012

Original operating manual

MANUAL CONTROL / SEMIAUTO TEMPERATURE CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM

VENTILATION SYSTEM SECTION VTL CONTENTS VENTILATION, HEATER & AIR CONDITIONER VTL-1 FUNCTION DIAGNOSIS... 3 PRECAUTION... 6 PREPARATION...

Product catalogue 2010

Eurovacuum Installations and Operating manual EV Series Vacuum pumps Models

Type 5411, Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type 6213 EV, 6281 EV

AIRTRONIC / AIRTRONIC M Troubleshooting and Repair Instructions

VENTILATION SYSTEM SECTION VTL CONTENTS VENTILATION, HEATER & AIR CONDITIONER VTL-1 PRECAUTION... 3 PREPARATION... 5 SYSTEM DESCRIPTION...

GL1200T Cut & Seal. (GL1200 Seal only)

SCdefault. 900 Installation instructions

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Car Battery Charger Instructions for Use

Antifreeze Type SYC1025 (Long life coolant) Mixing ratio (water:antifreeze) Cooling fan module Type Electric Capacity

Water heater unit. Thermo Top C Auxiliary Heating. for auxiliary heater C. Mazda 6 with standard Webasto Pre-heater. Diesel. 3 Pre-heater Z equipment

Vane pump, direct operated

Application cup for OptiFlex 2 GM03 manual powder gun

VENTILATION SYSTEM SECTION VTL CONTENTS VENTILATION, HEATER & AIR CONDITIONER VTL-1 SYSTEM DESCRIPTION... 3 PRECAUTION... 6 PREPARATION...

Operating Instruction. Junction Box 80 A/125 A. Part-Number BAL a-EN Original document page 1 of 20

e ALWAYS follow all Webasto installation and repair instructions and observe all warnings.

X.. Series Helical and Bevel-Helical Gear Units

Technical Documentation Radial Pump with Canned Motor Y-1638-MM

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

TPAK Series COOLANT PUMP

basic quattro No /

Swiveling gripper finger GFS 16-40

Rexroth Hydraulics. Fixed displacement vane pumps Types PVV and PVQ RE /11.97

Power consuption motor (motion) Power consuption standby (end position) Position feedback Auxiliary switch Contact load Switching point

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

Ordering designation: G(Type) - (Stroke) - (Eye bolt) - (Cable length) - (Options) Legend:

Operating / Assembly Instructions Type A and CS Coupling

Technical Documentation Radial Pump with Canned Motor MY-3-MM

User Manual Rittal PMC UPS 6kVA

Transcription:

1/8 Heater Mini Content: 1 Safety advises 2 Device description 3 Function description 4 Operation 5 Installation 6 Technical data 7 Maintenance 8 Spare parts 9 Optional accessories 10 Fault diagnosis A U R O R A Konrad G. Schulz GmbH & Co. KG Tel.: 0 62 84 / 92 02-0 info@aurora-eos.com www.aurora-eos.com The information on this document and the copyrights are ownership of AURORA Konrad G. Schulz GmbH & Co. KG, Joachim Schulz str.4, D-69427 Mudau. Transmission or duplication of this document or the utilization of the contents is not allowed without the agreement of AURORA Konrad G. Schulz GmbH & Co. KG otherwise it is explicit allowed. Violation will be prosecuted. All rights of patents, industrial designs and trademarks are reserved. Please pay attention to ISO 16016. We reserve the right to make technical modifications author: 15.04.1999 KH checked: 25.03.15 CK released: 25.03.15 i.a.ck date/name date/name date/name a) 7726 14.05.01 KH e) 11717 11.07.06 KH i) 20613 11.11.13 KH b) 8639 19.03.03 KH f) 12014 24.10.06 KH j) 21985 10.03.15 KH c) 9708 28.06.04 KH g) 16415 05.10.10 KH d) 11440 18.04.06 KH h) 19358 08.11.12 KH

2/8 1 Safety advises Please consider the following advice for your own safety. Please have maintenance work and repairs exclusively carried out by authorised personnel. Do not grip into the unit and do not put objects inside. Maintenance work is to be carried out only when the blower-motor is not running. In order to avoid injuries, the motor is to be separated from the current circuit. Attention! Danger of burning! Please do not get into contact with the heat exchanger and its connections. Cooling tubes and cooling hoses can be hot and stand under pressure. Be careful by touching them. This also applies for 2-speed versions to the resistor when working at the opened unit and the construction part has not completely cooled down. Attention: cables may not affect the resistor! At maintenance work and repairs wear necessary protective clothing. Advice for installation and maintenance work: Please pay attention to the rules for the prevention of accidents. 2 Device description The heater versions differences are the nominal voltage, the air outlets and the heat exchanger connections. This technical information is valid for the following versions: AURORA-part nominal Air outlets Heat exchanger connection- voltage 151-301/302-0000 12V/24V 2 air grids 120x60 mm 12 straight connection 151-301-0001 12V 2 air grids 120x60 mm 12 straight connection 151-301/302-0002 12V/24V 2 air grids 120x60 mm 12 90 connection 151-301/302-0003 12V/24V 2 air grids 120x60 mm 12 90 connection 151-301/302-0004 12V/24V without air grids 12 straight connection 151-301/302-0005 12V/24V without air grids 12 straight connection 151-301/302-0006 12V/24V without air grids 12 90 connection 151-301/302-0007 12V/24V 2 air grids 120x60 mm 12 90 connection 151-301/302-0008 12V/24V 2 air grids 120x60 mm 15 straight connection 151-302-0009 24V 2 air grids 120x60 mm 12 straight connection 151-302-0010 24V 2 air grids 120x60 mm 15 straight connection 151-301/302-0011 12V/24V 2 air grids 120x60 mm 12 straight connection 151-301-0012 12V air outlet box with 2 oval 12 straight connection sockets 151-301-0013 12V angular air outlet hood 12 straight connection 151-301-0014 12V air outlet hood with socket 12 straight connection 70 mm 151-301-0015 12V air outlet hood with socket 12 straight connection 70 mm 151-301/302-0016 12V/24V air outlet box with flap and 1 socket 70 mm 12 straight connection

3/8 AURORA-part nominal Air outlets Heat exchanger connection- voltage 151-301-0017 12V air outlet box with flap and 1 12 straight connection socket 55 mm 151-301/302-0018 12V/24V air outlet box with flap and 1 12 straight connection socket 55 mm 151-301/302-0019 12V/24V air outlet box with flap and 1 12 straight connection socket 55 mm 151-301/302-0020 12V/24V air outlet box with flap and 2 12 straight connection 151-301/302-0021 12V/24V air outlet box with flap and 2 12 straight connection sockets 55/ 42 151-301/302-0022 12V/24V air outlet box with flap and 2 12 straight connection 151-301/302-0023 12V/24V air outlet box with flap and 2 12 90 connection sockets 55/ 42 151-301-0024 12V air outlet box with 1 socket 12 straight connection 42 mm and 1 oval socket 78x55x3 151-301-0025 12V air outlet box with flap and 1 12 straight connection socket 78x55x3mm 151-301-0026 12V air outlet box with flap and 1 12 straight connection socket 55 mm 151-301-0027 12V air outlet box with flap and 2 12 straight connection oval sockets 151-301-0028 12V air outlet box with flap and 1 12 straight connection 151-301/302-0029 12V/24V air outlet box with flap and 1 12 straight connection 151-301-0030 12V air outlet box with flap and 2 12 straight connection 151-301-0031 12V air outlet box with 1 socket 15 90 connection 55 mm 151-301-0032 12V 2 air grids 120x60 mm 12 straight connection 151-301-0033 12V 2 air grids 120x60 mm 12 90 connection 151-302-0034 24V 2 air grids 120x60 mm 12 straight connection 151-302-0035 24V 2 air grids 120x60 mm 12 straight connection 151-301/302-0036 12V/24V air outlet box with flap and 2 12 straight connection 151-301-0037 12V/24V air outlet box with 1 socket 12 straight connection 80 mm 151-302-0038 24V 2 air grids 120x60 mm 12 straight connection 151-301/302-0039 12V/24V 2 air grids 120x60 mm Ø12 90 connection 151-301-0040 12V air outlet hood with round 15 bent connection nozzle RD 85.0 151-302-0041 24V air outlet hood Ø70 15 straight connection 151-301/302-0042 12V/24V 2-speed with resistor 15 straight connection 151-301-0043 12V air outlet hood Ø70 15 bent connection 151-302-0044 24V air outlet hood Ø70 15 straight connection 151-301/302-0045 12V/24V 2-speed with resistor 15 straight connection 151-301-0046 12V 2-speed with resistor air outlet hood Ø70 180 rotated from the suction side 12 straight connection Note: Some versions are no longer available

4/8 The Mini heaters are developed for the heating of cabins. The heater can basically be operated with external or recirculating air. Therefore have the requirements set into the vehicle according to the operation situation. The heater is delivered by AURORA completely pre-mounted, the installation into the vehicle is carried out by the customer. The heat exchanger and the fan wheel with motor are integrated into the heater. housing: The housing is made from glass-fibre reinforcement polyamide PA6. Blower function: A direct current motor and a fan wheel, is used. For the 2-speed version a resistor is integrated. The different blower speeds are achieved using the pre-resistor. The fan unit is protected against overload by a micro-temperature-fuse MTS (110 C) connected to the resistor. Heat exchanger-system: A flat tube heat exchanger is used. The water connection diameter is 12 mm (or. 15 mm for 151-301/302-0008, 151-301-0031, 151-301-0040, 151-302-0041, 151-301/302-0042, 151-301-0043, 151-302-0044 and 151-301/302-0045). Examples of different Mini-versions

5/8 3 Function description The air is be sucked through the suction grid. The air flows through the heat exchanger and will be lead through the air outlet grille and/or the sockets into the interior room. The suction grid has the dimensions 113x113 mm. The air direction can be changed by rotating the air outlet grille by 90. 4 Operation A AURORA control panel (accessories) can be used. 5 Installation Please pay attention to the actual technical supplement to the general terms of sale and the safety instructions in contact & Info of www.aurora-eos.com. Please note: max. allowable pressure for flat tube heat exchangers: 2 bar abs. The Mini can be installed in variable positions. Please pay attention to the air suction grille in the installed position. The air suction grille shall not be disguised or closed. For fixing, screws M5 in corresponding lengths can be used in connection with screw anchors with an inner diameter of M5 (part number 497-900-0004, length 16 mm, to be set into drills from the outside). The screw length differes according to vehicle. According fixing drills are on the bottom or can be drilled at marked position on the housing. During setting the drills, please, make sure that inside components are not damaged. As an option fixing elements can be supplied by AURORA. After installation of the Mini the electrical, the water side connection and optional the air hose connections have to be set. Electrical connection for 2-speed versions: 12V: customer pre-fusing 3A necessary 24V: customer pre-fusing 2A necessary Attention: cables may not affect the resistor!

6/8 Connection sceme resistor: View on plug please see drawing of the according version. The warm air hoses are pushed over the heaters sockets (option). It is essential to use appropriate hose clips for connecting the warm water hoses to the heat exchanger with a tightening torque of approx. 3-3,5 Nm (if using AURORA-clips). Check the system on leaks. Check also the function of the fan unit and the air direction by switching on the blower (airflow at the outlet nozzles or socket). 6 Technical data Technical data for standard modells151-301/302-0000: V water = 1000l/h test voltage. 13 V / 26 V V air [m³/h] Q 80 [kw] P el [W] L P [db(a)] ± 0,5 114 2,1 29 64 The technical data of the other versions are assimilable. 2-speed version: 12V: Test result from 16.10.2006: Test voltage 13V: [current + speed tolerance ±10%] at 23 C±5K, free blowing speed 1 ca. 1,4A current consumption speed ca. 3665 1/min speed 2 ca. 1,8A current consumption speed ca. 4470 1/min Measurement under laboratory conditions

7/8 24V: Test result from 16.10.2006: Prüfspannung 26V: [current + speed tolerance ±10%] at 23 C±5K, free blowing speed 1 ca. 0,7A current consumption speed ca. 3665 1/min speed 2 ca. 0,9A current consumption speed ca. 4470 1/min Measurement under laboratory conditions Housing and air outlet hood orair outlet box made of polyamide PA6 GF35. Frame and air grille are also made of polyamide PA6 GF35. This granulate is certified to UL-HB concering burning behaviour: Further information about burning behaviour of this material: See material specification 971-820-0002. EMC: Depending on version the motor has type approval regarding ECE R10 or the complete Heater is type approved according directive 72/245/ECC. 7 Maintenance CAUTION Please pay attention to the safety advises (chapter 1) during all maintenance work. Maintenance work is only carried out by wellinformed and authorised personnel. The following checks should be carried out every month by the operator: - Check of the fixing, leak control and laying of the hoses and fittings. The hose fixings are to be tightened if necessary. - Check electric connection pipes and plug connections on correct state and firm position. Cooling water circuit: When refilling the cooling water quality has to be considered. When using AURORA water valves the warranty expires when defects occur due to contamination in the water circuit. (see TI 971-190-0003 anticorrosion/antifreeze solution. Please order in the case of need) The air suction grid has to be checked on contamination and cleaned if necessary in regularly intervals. 8 Spare parts We can deliver the heat exchanger, the motor, the fan wheel, the resistor, the cable set or the air grid as spare parts. For versions with hood the hood is also spare part. For the 2-speed version a resistor is spare part. Please see spare parts list of the heaters. More information about spare parts please see spare parts list of the respective heater. 9 Optional accessories As well as the control panel and the water valve a comprehensive range of accessories have been especially developed for the Mini. Details upon request.

8/8 10 Fault diagnosis Fault Cause Remedy No air flow Fuse defective or loose Check the seating of the fuse? If necessary insert correctly. Renew defective fuses. Interruption of line Test lines on loose contacts or breaks Blower motor defective replace motor Mini will not operate at all speeds (2- speed versions) No or insufficient heating power Water escaping from the unit switch for blower defective Micro-temperature fusing (MTF) has been triggered Switch for blower defective Connecting plug has become loose Resistor defective Water supply temperature to low Water valve will not open fully change operation element Exchange resistor and check the blower motor for the cause of functional faults change operation element Check plug connection of unit for proper seating. If not assemble it correctly Check connection on switch Exchange resistor Wait until the motor is warm Check & renew water valve if necessary incl. actuation operation, check flow direction Check heat exchanger and clean it if necessary Heat exchanger fins contaminated Water lines kinked or squashed Eliminate fault by installing correctly Hose connection has come Check hose seatings and tighten hose loose clamps Water hose damaged Install and connect new hose Heat exchanger damaged Install and connect original replacement part. Warning! Follow safety instructions! coolant system pressure too high reduce absolute coolant pressure max. allowable pressure: 2 bar