MARCH COYOTE 9.5 x 19 (292 mm x 509 mm) Terminal Dome Closure Kits

Similar documents
COYOTE 9.5" x 19" (292 mm x 509 mm) Dome Closure

COYOTE 9.5" x 19" (292 mm x 509 mm) Cross-Connect Dome Closure

COYOTE Terminal Dome Closure 6.5" x 22"

JANUARY 2015 NOMENCLATURE. TOOLS REQUIRED 3/8" & 7/16" Can wrench or socket 1/4 Nut driver or screwdriver Snips Fiber optic cable opening tools

COYOTE Dome Closure 6.5" x 22" Kits. COYOTE Dome Closure 6.5" x 22" for Buffer Tube Applications. Includes: (2) Grommets, (1) Buffer

Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application.

COYOTE Dome Cross-Connect Closure 6-1/2" x 22"

COYOTE Dome Closure 9.5" x 28" with Transition Tray for High Density Splice Applications

COYOTE 28" GLC (Ground Level Closure) Complete Assembly Installation

COYOTE LCC (Low Count Closure)

COYOTE STP (Service Termination Point)

COYOTE STP (Service Termination Point)

COYOTE CLOSURE ADOBE SERIES FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (152.4 mm x mm mm x 558.

OFE-CLS-Type Outside Plant (OSP) Fiber Optic Closures Instructions

Section 1 COYOTE Closure Series

COYOTE Splice Case. Value conscious and benefit-packed: The COYOTE Splice. 2-2 (440)

COYOTE Splice Case. Value conscious and benefit-packed: The COYOTE Splice 2-2

Section 1 COYOTE Closure Series

Closure End Plates and Accessories

Section 1 COYOTE Closure Series

PLP Compression Dead-end & Jumper Terminal for ACSR & ACSS Conductors

COYOTE Closure. Origin of the Species. Key Features: PATENTED 1-14

INSTALLATION INSTRUCTIONS

Section 3 FIBERLIGN Closure Series

CS Fiber Optic Splice Case. Instruction

Features: Use the selection chart below to choose the Splice Case and splice tray organizer which meet the requirements for your application.

Mini-OTE 400. Mini-OTE 400. Content 1 General 1.1 General product information 1.2 Cable types 1.3 Symbols in this guide.

Environmental Distribution Center (EDC-06P-NH)

SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks

INSTALLATION INSTRUCTIONS

Fiber Splice Panel Rack Mount User Manual

COYOTE. Retrofit Closure. Refinement of the Breed. COYOTE Retrofit Closure. The ideal Closure for replacement or expansion 1-29

3000SC Fiber Optic Splice Closure

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

OFS 400A FIBER OPTIC INTERCONNECT Instruction Sheet UNIT (FOIU) Comcode INSTALLATION

3M Fiber Dome Closure FDC 10

Fiber optic splice closure

SJOF-BS604A Fiber Optic Splice Closure User Manual Rev.0

FOSC-400D5 INSTALLATION INSTRUCTION. Fibre Optic Splice Closure with integrated organiser system

Section 1 COYOTE Closure Series

OPTICAL FIBER CLOSURE

Pretium Wall-Mountable Housing (PWH-02P/-04P/- 06P/-12P and FZB-02P-JB)

Opti-Guard Splice Enclosure

Installation Instructions

8400 Series Fiber Distribution System

JBM-100-STB NEMA 4X-rated connection kit Installation Instructions

WRSS Wraparound Repair Sleeve Installation Instructions

FOSC-400A4 INSTALLATION INSTRUCTION

FIST-GSS2 FIST-GSS3. Fist Generic Splicing Shelf. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

SPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions

Installation Instructions INDY SHIFTER Fits: Mustang Fastback & Convertible with MT-82 Transmission Catalog #

3 Turbo Downpipe Installation Audi A3 / Volkswagen GTI / Volkswagen Jetta 2.0L FSI/TSI Turbo CD100013

Section 10 ARMADILLO Stainless Series

1 GENERAL INFORMATION

THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION.

Fiber Connector Shelf (CCS)

FIST-GSS2. Fist Generic Splicing Shelf MK2. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

Installation Instructions

Chengdu Qianhong Communication Co., Ltd. Fiber Optic Splice Closure. GJS03-M8AX-JX-144D-Mechnical Sealing Way.

One- Touch Installation Instructions

3M Closure System 2-Type Cover (505)

LIGHT DUTY ROLL UP DOOR

INSTALLATION INSTRUCTIONS FOR DSP9600/9100 WHEEL BALANCER

Slack Span Dead-end GENERAL RECOMMENDATIONS NOMENCLATURE (440)

2015+ S550 MUSTANG Battery Relocation Kit WR-BTRYRELOKIT-LH WR-BTRYRELOKIT-RH

PMKG-JS POLYMATRIX SPLICE CONNECTION KIT INSTALLATION INSTRUCTIONS

FIST-GMS2. FIST Generic Mixed Shelf MK2. Contents. 1 Introduction. 5 Termination of the pigtails. 2 General. 6 Splicing + fiber storage

UNSIGNED HARDCOPY NOT CONTROLLED

PONTIAC FIREBIRD

PMKG-J2LP PolyMatrix Powered Splice Kit Installation Instructions

YOURx-Aerial Terminal Installation Manual

C A Heating Cable Gland Kit Installation Instructions

JBS-100-STB Single Entry Power Connection with Junction Box Installation Instructions

Exhaust System Installation Turbo Downpipe Audi MKII TT-RS 2.5T CD100028

FOSC-100 B/H FOSC-100 B2/H

12-Inch Hybrid Fiber Access Terminal Installation Instructions

FIBER CONNECTOR SAFETY WARNINGS

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits

Instructions for Use - Opt-X 1000i Enclosure

THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION.

FL2000 Termination/Splice Panels User Manual

UNPACK AND IDENTIFY THE FOLLOWING PARTS.

Cold Shrink QS T Trifurcating Transition Splice Kit

LPE C5 Battery Relocation Kit

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination

OFS LSS1U-864/ Instruction Sheet Fiber Optic Comcode: Splice Shelf Installation

PART NUMBER POLE DIAMETER RANGE CARTON QTY " to 5" " to 6 3 4" " to 7 3 4" " to 8 3 4" 10

COOPER POWER SERIES. 200 A Fused Loadbreak Elbow Connector Replacement Fuse Installation Instructions. Fusing Equipment MN132021EN

SAFETY THIS PRODUCT IS FOR OFFROAD USE ONLY. ALL LIABILITY FOR INSTALLATION AND USE RESTS WITH THE OWNER.

Do not have any open flame or heat sources close to the installation

INSTALLATION & OWNER S MANUAL

1989 Jeep Cherokee. STEERING COLUMN' '1989 STEERING Jeep Steering Columns STEERING COLUMN STEERING Jeep Steering Columns

FIST-GPS2-J. 19 2HU Splicing, Patching and Storage shelf. 5 Fiber routing. 1 Introduction. Contents. 2 General. 6 Storage. 3 Installation of the shelf

Universal Splice Tray Installation Instructions

Installation Instructions COMPETITION/PLUS SHIFTER Ford Mustang MT82 6-Speed Manual Transmission Catalog#

Section 7 - Troubleshooting Guide

American Standard ProAx Triaxial Camera Connectors Installation Instructions

Kit No Please read these instructions completely before proceeding with installation. Air Spring Kit Parts List. Bracket Attaching Hardware

69-74 VW Beetle IRS Rear Kit Part No

PILLOWS DECK-MOUNT BATH FAUCET WITH FLUME SPOUT

Transcription:

MARCH 2012 COYOTE 9.5 x 19 (292 mm x 509 mm) Terminal Dome Closure Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application. 1 2 4 5 3 6 7 8 NOMENCLATURE 1. Dome Cover (1) 2. Organizer Assembly with Hardened Adapter End Plate (1) 3. LITE-GRIP Short Splice Tray (1) 4. Dome Collar (1) 5. Dome Gasket (1) 9 10 11 12 13 14 15 6. Long Strength Member Bracket (2) 7. Short Strength Member Bracket (2) 8. Large Strength Member Adapter Kit (1) 9. Transition Tube Kit (1) 10. Grommet (4) 11. Hose Clamp (4) 16 12. Silicone Lubricant (4 five gram packets) 13. Storage Bracket Retainer Clips (4) 14. Nut (11) 15. Lock Washer (11) 16. Pigtail Kit (1-2 depending on closure kit) COYOTE 9.5 x 19 (292 mm x 509 mm) Terminal Dome Closure Kits Catalog Number Description COYTD919B0-000 COYOTE 9.5 x 19 Terminal Dome Closure with 0 Hardened Adapters Buffer Tube Applications COYTD919B2-000 COYOTE 9.5 x 19 Terminal Dome Closure with 2 Hardened Adapters Buffer Tube Applications COYTD919B4-000 COYOTE 9.5 x 19 Terminal Dome Closure with 4 Hardened Adapters Buffer Tube Applications COYTD919B6-000 COYOTE 9.5 x 19 Terminal Dome Closure with 6 Hardened Adapters Buffer Tube Applications COYTD919B8-000 COYOTE 9.5 x 19 Terminal Dome Closure with 8 Hardened Adapters Buffer Tube Applications COYTD919R0-000 COYOTE 9.5 x 19 Terminal Dome Closure with 0 Hardened Adapters Ribbon Applications COYTD919R2-000 COYOTE 9.5 x 19 Terminal Dome Closure with 2 Hardened Adapters Ribbon Applications COYTD919R4-000 COYOTE 9.5 x 19 Terminal Dome Closure with 4 Hardened Adapters Ribbon Applications COYTD919R6-000 COYOTE 9.5 x 19 Terminal Dome Closure with 6 Hardened Adapters Ribbon Applications COYTD919R8-000 COYOTE 9.5 x 19 Terminal Dome Closure with 8 Hardened Adapters Ribbon Applications Accessory Kits 80808456 COYOTE Dome End Plate Fixture 8003715 Hardened Adapter Kit with Installation Tool 8003724 Plug Kit with Installation Tool 80807972 Adapter Installation Tool Mounting Brackets 8003940 Aerial Mounting Bracket (Dome Mount) 8003941 Aerial Mounting Bracket (End Plate Mount) 8003940 Aerial Hanger Bracket Kit (For Strand) 8003869 Aerial Hanger Bracket Kit (For ADSS) 8003942 Pole/Wall Mounting Bracket 8004000 Hand Hole Dome Mounting Bracket 2012 Preformed Line Products Company. All rights reserved. 1

COYOTE Grommet Chart For use in COYOTE GLC, Aerial, LCC, Dome, In-Line RUNT, Taut & Terminal Closures PLP Catalog Number Cable Range Inches (mm) Description Splitting Location 8003691.42 -.60 (11-15 mm) 1-entry grommet 8003692.60 -.85 (15-22 mm) 1-entry grommet 8003693.85-1.0 (22-25 mm) 1-entry grommet 8003694 1.0-1.25 (25-32 mm) 1-entry grommet 8003663.42 -.60 (11-15 mm) 2-entry grommet 8003664.30 -.43 (8-11mm) 4-entry grommet 8003989 Flat Drop Only 4-entry grommet 8003665.125 -.25 (3-6 mm) 6-entry grommet 8003676.42 -.60 (11-15 mm).125 -.25 (3-6 mm) 7-entry grommet 8003677.125 -.25 (3-6 mm) 8-entry grommet NOTE: Grommet Kit contains (1) Grommet, (1) Cable Measure Tape, (2) Silicone Lubricant Packs, (1) Set of Plugs & (1) Glove Splice Tray/Closure Capacities for COYOTE 9.5 x 19 (292 mm x 509 mm) Terminal Dome Closure Splice Tray Catalog Number Splice Type Low Profile LITE-GRIP (24 ct) Standard (12 ct) 80806033 Deep Profile LITE-GRIP (40 ct) Deep Profile LITE-GRIP (144 ct) Trays per Closure Closure Splice Capacity Buffer Tube Ribbon Buffer Tube Ribbon 80809958 Single Fusion 11 6 264 144 Single Fusion or Mechanical 8 4 96 48 80808945 Single Fusion 5 3 200 120 LGSTR144 Mass Fusion/ Ribbon N/A 3 N/A 432 2

END PLATE PREPARATION CABLE PREPARATION Step #1 Remove end plate from organizer. Step #4 Measure cable to determine diameter and hole location to use in grommet. Step #2 Remove the end plate caps from each cable port and break out all cable port tabs. Step #5 If using cut cable, insert cable through grommet. If your application requires express/balloon/ring cut cables, see Step 7 for grommet slitting procedure. Diameter range PLP Tip: Scoring edges of tabs with knife makes them break out easier. End plate with all cable port tabs removed. Step #6 Install plug in unused port. Installing Figure 8 Style Cables and Cables with Tracer Wires - Remove tracer wire or ground wire from the portion of the cable that will be positioned in the grommet and insert cable into grommet. Cable with Tracer Wire Step #3 Determine which cable ports will be used. Not NOTE: If buffer tubes are routed in bottom storage brackets, use cable ports 2 & 3. If ribbon cables are being used or buffer tubes are routed in side storage brackets, use cable ports 1 & 4. 4 1 3 2 Correct Not Correct Installation Correct Installation Figure 8 Style Cable Not Correct Not Correct Installation Correct Installation 3

Step #7 Grommet Slitting If slitting is required, lay grommet on a stable flat surface. Position utility knife with the cutting edge against the top surface and cut through grommet. Consult grommet chart on page 2 for slitting locations of all grommets. Step #9 Prepare loose tube/buffer tube or unitube/ ribbon cable(s) for mid sheath applications (Express/Balloon/Ring Cut). 77 (2.0 m) Buffer (Loose) Tube Cable OFFICE/C.O. PLP Tip: Use a pen to sketch slitting lines on top surface of grommet prior to cutting. Not Correct Slit Slit Buffer Tube (After Cut) A X Ribbon Cable Slit Slit OFFICE/C.O. Not Correct Slitting Angle Correct Slitting Angle 77 (2.0 m) Step #8 Prepare loose tube/buffer tube or unitube/ ribbon cable(s) for cut applications. Ribbon (After Cut) X A Min. of 77 (2.0 m) Minimum Sheath Opening for Cut Cable Applications 77 Min. 2.0 m Min. PLP Tip: Leave about 8 (203 mm) of strength member to trim later. NOTE: When expressing ribbons in the transition tray of the closure at this measurement, the maximum number of ribbons that can be expressed is 24 ribbons (288 fibers). For Applications Where Fiber is Dedicated to the Splice Point Sheath Opening 77 (2.0 m) Min. Fiber/Buffer Tube Cut Location A (see image above) PLP Tip: Leave about 8 (203 mm) of strength member to trim later. 4

Step #10 B X Prepare loose tube/buffer tube or unitube/ ribbon cable(s) for mid sheath applications (Express/Balloon/Ring Cut). Buffer Tube (After Cut) 154 (3.9 m) Buffer (Loose) Tube Cable OFFICE/C.O. Step #11 Prepare loose tube/buffer tube cable(s) for expressed fiber (buffer tube window cut) Expressed Fiber (After Cut) X C Buffer Tube Opening Location for Window Cut 112 (2.8 m) OFFICE/C.O. X C Buffer Tube (After Cut) Buffer Tube Opening Location for Window Cut B X Ribbon (After Cut) OFFICE/C.O. 154 (3.9 m) Ribbon Cable For Applications Where Fiber is Expressed through the Buffer Tube. Sheath Opening 112 (2.8 m) Min. Buffer Tube Window C (see image above) Cut Locations PLP Tip: Leave about 8 (203 mm) of strength member to trim later. Ribbon (After Cut) X Step #12 Prepare Central/Buffer Tube(s) for Unitube/Ribbon Cable Applications NOTE: When expressing ribbons in the transition tray of the closure at this measurement, the maximum number of ribbons that can be expressed is 12 ribbons (144 fibers). Cable in Entry Ports 1 and 4 4.5 (11.3 cm) For Applications Where Fiber is NOT Dedicated to the Splice Point Sheath Opening 154 (3.9 m) Min. Fiber/Buffer Tube Cut Location B (see image above) PLP Tip: Leave about 8 (203 mm) of strength member to trim later. Step #13 If the cable contains Kevlar, braid roughly 3 (7.2 cm) of the Kevlar. 3 (7.2 cm) Kevlar is a registered trademark of DuPont. 5

Step #14 Align sheath opening with end of slot of the strength member bracket as shown. Step #16 Install cap on strength member bracket. Short Strength Member Bracket Long Strength Member Bracket Step #17 Position strength member under cap of strength member bracket. Step #15 Trim strength member(s) flush with end of the strength member bracket(s). Step #18 If the cable contains Kevlar, wrap the braided Kevlar around the stud of the cap as shown. 6 Kevlar is a registered trademark of DuPont.

Step #19 Tighten nut of cap to secure strength member and braid under the cap. Installing Strength Member Adapter for Large Cable Strength Members Step #21 For large cable strength members, assemble the adapter to the long strength member bracket as shown. Open Cap Adapter Long Strength Member Bracket Nut Step #20 Secure cable to strength member bracket with hose clamp. Step #22 Secure large cable strength member(s) to adapter with small hose clamp. Short Strength Member Bracket Small Hose Clamp Step #23 If the cable contains Kevlar, wrap the braided Kevlar around the stud of the cap as shown. Long Strength Member Bracket Step #24 Tighten nut of cap to secure under the cap. Nut 7

Step #25 Secure cable sheath with hose clamp. Step #29 Lubricate the outer surface of the grommets. Hose Clamp Attaching Shielded Cable to Strength Member Bracket Lubricate sealing surface of grommet with silicone lubricant provided. Step #26 For shielded cable applications, PLP recommends using a 3M 4460-D/FO Fiber Optic Shield Connector (PN: 80803989). Install shield connector on cable and insert stud of shield connector through slot of strength member bracket. Step #30 Position grommets in end plate slots. NOTE: Visually inspect to confirm buffer tubes are not pinched or distorted as shield connector is secured to bracket. Follow standard company practices when applying shield connector to cable. Step #27 Secure shield connector to strength member bracket with nut and secure cable strength member under cap of the strength member bracket. Do not align grommet slit with end plate seam. Step #31 Position slot of strength member bracket leg over stud and pull back cable. NOTE: Visually inspect to confirm buffer tubes are not pinched or distorted as shield connector is secured to bracket. Step #28 Secure shielded cable to strength member bracket with hose clamp. NOTE: Visually inspect to confirm buffer tubes are not pinched or distorted as hose clamp is secured to bracket. 8

Step #32 Install strength member bracket on stud. Install lock washer and nut against the bracket, but do not tighten fully, so the bracket can slide as the grommet is inserted. Step #35 Complete end plate assembly. Lock Washer & Nut Step #33 Install grommets with plugs in any unused cable port. Step #36 Re-install end plate onto organizer assembly and secure with bolt. Make sure there is a plug installed in each grommet hole. Step #34 Install cable caps and secure with hex bolts. Fully tighten nut against the strength member bracket. NOTE: Tighten bolts by hand evenly until cable cap is fully seated (DO NOT USE POWER TOOLS TO TIGHTEN BOLTS). When using a can wrench or nut driver, the installed torque is 35 to 40 in. lbs. NOTE: TIGHTEN ALL CABLE CAPS. IMPORTANT: tighten the STRENGTH MEMBER after the caps are tightened. 9

Step #37 Buffer Tube Applications Route and store buffer tubes in storage brackets. If routing in side storage brackets, see Step #38 for installation of retainer clips. Step #39 Route buffer tube(s) to splice tray(s) and secure. Unitube/Ribbon Applications Step #40 Route and secure central tube of unitube cables to transition tray. Step #38 To install retainer clip, position the bottom slot of the retainer clip onto the bottom of the bracket. Tilt retainer clip forward until the top of the bracket snaps into the top slot of the retainer clip. Before Step #41 Route feeder fibers or ribbons within transition tray. After 10

Step #42 Install organizer clips in transition tray and route expressed fibers or ribbons under clips. Step #45 Route transport tube(s) to splice tray(s) and secure. Organizer Clip Pigtail Assembly Installations Step #43 Insert fibers or ribbons to be routed to splice tray(s) into transport tube(s) and secure tubes to transition tray. Step #46 Measure and mark pigtail. Remove the pigtail jacket and Kevlar beyond this mark. Minimum of 25 (64 cm) from connector edge Step #44 Install cover on transition tray. Step #47 Install pigtails into LITE-GRIP Sleeve. Cover Kevlar is a registered trademark of DuPont. 11

Step #48 Install LITE-GRIP Sleeve with pigtails into splice tray. Step #52 Secure splice tray(s) with hold down strap. Before After Splice Tray Management Step #49 Route incoming fibers in splice tray. Pigtail Routing Step #53 Route pigtails to end plate as shown. Step #50 Route outgoing pigtail fibers in splice tray. Step #54 Install pigtail connectors into adapters. Step #51 Splice incoming fibers to outgoing pigtail fibers per your accepted company practices. 12

Dome Preparation & Installation Step #57 Make sure to align the notches of the gasket as shown below. Step #55 Lubricate all surfaces around gasket with silicone lubricant to assure easy assembly and closure re-entry. Lubricate all inner surfaces of the gasket. Align notch of gasket with this seam. Align notch of gasket with this seam. Lubricate all outer surfaces of the gasket. Seam Notch in gasket Step #56 Slide the gasket onto the end plate and press into groove. Make sure to orientate the gasket so that the wide inner flange area of the gasket is seated in the groove of the end plate in the section shown below. Make sure gasket is seated in groove of end plate. Step #58 Re-tighten all cable cap bolts (Step #34) to ensure that the cable caps are fully seated. When using a can wrench or nut driver, the installed torque is 35 to 40 in. lbs. Step #59 Position dome over end plate. Wide Inner Flange Place the wide inner flange of the gasket in this section of the end plate. 13

Step #60a Install dome collar. Step #62 Install drop cable connectors into adapters. Notch Arrow NOTE: Make sure arrow of connector is aligned with notch of adapter when installing connector. Step #60b Make sure lip of dome is captured underneath the collar before securing the latch. Lip of Dome Step #61 Lock collar by twisting the latch fastener clockwise 90 degrees. CAUTION: Do not fasten latch until collar is completely installed in the correct position or damage to latch may occur. Latch Fastener 14

Flash Test Procedure Step #63 Remove cap from air valve of end plate. Step #65a Spray all sealing surfaces of the dome end plate with soapy water to determine if there are any leaks. Step #64 Pressurize closure up to a max of 10psi. Step #65b For Terminal Dome Closures, make sure to spray and check for leaks around the O-Rings of the hardened adapters. O-Ring of Hardened Connector 15

Step #66 Release the pressure in the closure using the bump on the top of the air valve cap. Troubleshooting End Plate Leaks Leak ocurring at the corner of the cable port due to the cap of the cable port not being fully tightened. Bump of Air Valve Cap Leak occurring at the corner of the cable port To resolve, remove collar, remove End Plate/Organizer Assembly from the Dome, and tighten bolts on end cap where leak occurred. Reassemble and flash test to confirm that the leak has stopped. Leak ocurring at the cable entry of the grommet due to the cable not being within the stated cable diameter range of the grommet. Leak occurring at the cable entry of the grommet To resolve, remove collar, and remove End Plate/ Organizer Assembly from the Dome. Remove end cap where leak occurred, remove grommet, remeasure cable with measure tape provided and select proper grommet. Reassemble the components and flash test the closure to confirm that the leak has stopped. 16

Optional Hardware for Mounting Step #67 9.5 (292 mm) Dome Aerial Mounting Bracket End Plate Mount for ADSS Applications. The COYOTE 9.5 Dome Aerial Mounting Bracket Kit (Cat. No. 8003941) can be used to suspend the COYOTE 9.5 x 19 (292 mm x 509 mm) or 9.5 x 28 (292 mm x 749) Dome Closure from ADSS cable. To install the aerial mounting bracket, first secure the gusset bracket to the hanger bracket before attaching both to the studs of dome end plate. Next, attach the dome bracket to the mounting tabs of the dome. Lastly, attach a hanger strap bracket to the dome bracket and one to the back side of the hanger bracket before mounting the dome closure to the dead-end using the ADSS clamps of the hanger strap brackets. Hanger Bracket Gusset Bracket Hanger Strap Dome Mounting Tab Dome Bracket Step #68 9.5 (292 mm) Dome Aerial Mounting Bracket Dome Mount Applications. The COYOTE 9.5 Dome Mount Aerial Bracket Kit (Cat. No. 8003940) can be used to suspend the COYOTE 9.5 x 19 (292 mm x 509 mm) or 9.5 x 28 (292 mm x 749) Dome Closure from messenger wire. To install the dome mount aerial brackets, position the brackets in the banding channels of the dome and insert banding (plastic or metal) through the slots of the brackets. Tighten the banding until the brackets are secure before mounting the closure to the messenger wire with the bug nuts of the brackets. Bug Nut Dome Aerial Hanger Bracket Strap Dome Mount Aerial Brackets Banding Channels Step #69 9.5 (292 mm) Dome Aerial Mounting Bracket for ADSS Applications. The COYOTE 9.5 Dome Mount Aerial Bracket Kit for ADSS (Cat. No. 8003869) can be used to suspend the COYOTE 9.5 x 19 (292 mm x 509 mm) or 9.5 x 28 (292 mm x 749) Dome Closure from ADSS cable. To install the Dome Mount Aerial Brackets, position the brackets in the banding channels of the dome and insert banding (plastic or metal) through the slots of the brackets. Tighten the banding until the brackets are secure before mounting the closure to the dead-end with the ADSS clamp. ADSS Clamp Dome Aerial Hanger Bracket Dome Mount Strap Aerial Brackets Banding Channels 17

Step #70 9.5 x 28 (292 mm x 749 mm) Dome Pole Mounting Bracket. The COYOTE 9.5 Dome Pole Mounting Bracket Kit (Cat. No. 8003942) can be used to secure the COYOTE 9.5 x 19 (292 mm x 509 mm) or 9.5 x 28 (292 mm x 749 mm) Dome Closure to wood, concrete, or steel poles. To install the pole mounting bracket, first secure the gusset bracket to the hanger bracket before attaching both to the studs of dome end plate. Step #72 Attach the dome pole mounting plate to the pole with either 5/8 (M16) through bolts, 1/4 (6.35 mm) lag screws, or metal banding. Hanger Bracket Gusset Bracket Step #71 Bolt Hole Tabs Attach the hanger bracket to the pole mounting plate with the gusset side facing the same side as the bolt hole tabs of the pole mounting bracket. Gusset Bracket Hanger Bracket Pole Mounting Plate 18

19

safety considerations This application procedure is not intended to supersede any company construction or safety standards. This procedure is offered only to illustrate safe application for the individual. Failure to follow these procedures may result in personal injury or death. Do not modify this product under any circumstances. This product is intended for use by trained technicians only. This product should not be used by anyone who is not familiar with, and not trained to use it. When working in the area of energized lines, extra care should be taken to prevent accidental electrical contact. For proper performance and personal safety, be sure to select the proper size PREFORMED TM product before application. Preformed products are precision devices. To insure proper performance, they should be stored in cartons under cover and handled carefully. P.O. Box 91129, Cleveland, Ohio 44101 440.461.5200 www.preformed.com e-mail: inquiries@preformed.com SP3107-1 20