Port size. 4(A), 2(B) port SV /2(P A/B) 4/2 3/5(A/B E) b

SV F. Series SV SV SZ SYJ. Series EX500 Decentralized Serial Wiring. How to Order Valve Manifold Assembly. How to Order Solenoid Valves

5 Port Solenoid Valve Series SV

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000

Gateway System Serial Transmission System

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications

Base Mounted Plug-in/Plug Lead: Single Unit

VQ1000. How to Order Manifold. Kit type

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating

3 Port Solenoid Valve

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring

4/5 Port Solenoid Valve

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot

Terminal Block Box (Spring Type) SY3000/5000/7000 Series

3 Port Solenoid Valve

New Concept Connector Type Manifold

Fieldbus System (Output device for driving 5 port solenoid valves)

4 Port Solenoid Valve Cassette Type Manifold Rubber Seal

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection

4/5 Port Solenoid Valve

5 Port Solenoid Valve

5 Port Solenoid Valve

Single Valve/Sub-plate Type IP67 Compliant 90-SV Series

Plug Lead Unit: Flip Type

5 Port Solenoid Valve

5 Port Solenoid Valve

How to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer

How to Order Manifold. Kit type L8 B4 B6 B8 LM

Series SYJ300/500/700

Series SV1000/2000/3000/4000

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I

Power Consumption. 4/5 Port Solenoid Valve. Series SYJ3000/5000/7000. With Power Saving Circuit

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications

5 Port Solenoid Valve

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

Example. U side. Stations SY5000

5 Port Solenoid Valve

3 Port Air Operated Valve. SYJA300 Series. How to Order. Nil Without sub-plate. Type of actuation. Normally closed Normally open

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A)

Series VQ Port Solenoid Valve

Fieldbus System (Gateway Decentralized Type)

How to Order Manifold. Control unit Refer to pages to Kit/Electrical entry/cable length. kit (D-sub connector) U0 U1 U2

Series VQZ1000/2000/3000 Single Unit

5 Port Solenoid Valve

CAT.E-155 A. Base Mounted Type. Series VQ Port Metal Seal/Rubber Seal Solenoid Valve

Gateway Type Serial Transmission System

5 Port Solenoid Valve

3 Port Solenoid Valve

Series PCW. PC Wiring System

Pilot Operated 2 Port Solenoid Valve for Dry Air

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

Series SY3000/5000 Base Mounted Manifold Stacking Type/DIN Rail Mounted Connector Box 24V. D side D. Blanking plate assembly SX A

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

0.35 W (Without light)

4/5 Port Air Operated Valve. SYJA3000 Series. How to Order. (Manifold use only) Type of actuation. 2 position single. 3 position closed center

Coolant Valve. Air Operated/External Pilot Solenoid

5 Port Solenoid Valve

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure

Series SYJ3000/5000/7000

3, 5 port pilot operated valve Pneumatic valve / master valve. Discrete valve. Manifold

Series SY3000/5000 How to Order Manifold

3 Port Solenoid Valve

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Series VP3145/3165/3185

4 Port Solenoid Valve

4 Port Solenoid Valve

Specifications. Fluid Ambient and fluid temperature ( C)

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

How to Order Manifold. Option Symbol

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

5 Port Solenoid Valve Plug Lead Type

Compact Vacuum Ejector

Space Saving Vacuum Ejector / Vacuum Pump System

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

3 Port Solenoid Valve Direct Operated Poppet Type

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

3 Port 3 Position Valve

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

How to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa

Transcription:

ir Cylinders rive System Full Stroke Time and Speed at the nd 000 Solenoid Valve pplicable related components Silencer Tubing Speed controller S0F -0-0 pplicable bore size: ø0, ø6, ø0, ø00 Total stroke time (s) 0.0 0. 0. 0.6 0..0...6..0 M ø0 00 0% 70% 0% 00 0% 00 00 70% 0% 0% 0% 0 Stroke (mm) M ø6 00 S0F -0-0 00 00 00 Stroke (mm) 00 N -C T07 M ø0 0 00 S000-0 00 00 00 Stroke (mm) 0 M ø00 00 S000-0 00 00 00 Stroke (mm) Solenoid valve Silencer Tubing pplicable related components Speed controller 00 00 00 00 600 700 00 900 000 00 00 Speed at the end (mm/s) 0 For details regarding different conditions, make determinations after using the SMC Model Selection rogram - neumatic Cylinder rive Systems. How to ead the Graph These graphs show the total stroke time and speed at the end when a cylinder drive system is composedof the ideal components. The graphs above indicate the total stroke time and speed at the end with respect to various load ratios and strokes for each cylinder bore size. Common Conditions Inlet pressure 0. Ma iping length 000: m, 000/000: m, 000: m Cylinder direction Vertical upward Speed controller Meter-out, irectly connected to cylinder, Needle fully open Load ratio {(Load weight x 9.) Theoretical output} x 00% --6

Valve Manifold Common Specifications For details about certified products conforming to international standards, visit us at www.smcworld.com. Cassette base manifold Changing the number of stations can be easily done by lever operation. Flow Characteristics Model S-6 S-6,, (,, ) C C0 ort size, (, ) C6 C C [dm /(s bar)] 0.9. Manifold Specifications pplicable series Manifold type (: SU)/, (: XH) type Valve stations (maximum) Max. number of solenoids (), /() port ort size (), () port Note) The value is for manifold base with stations and individually operated position type. 000 000 Stacking type cassette base manifold Common SU, XH stations 0 stations points 6 points C, N9 C0, N C, C, C6 C, C6, C N, N, N7 N, N7, N9 Flow characteristics / ( /) / / (/ ) b 0. 0. Cv 0. 0.0 C [dm /(s bar)] 0.9.7 b 0. 0. Cv 0. 0.6 Tie-rod base manifold pins connector allows up to 6 stations with double solenoids. Manifold Specifications pplicable series Manifold type (: SU)/, (: XH) type Valve stations (maximum) Max. number of solenoids (), /() port ort size (), () port Flow Characteristics 000 C, N9 C, C, C6 N, N, N7 000 000 Tie-rod base manifold Common SU, XH 0 stations points C0, N C, C6, C N, N7, N9 C, N C6, C, C0 N7, N9, N ort size Flow characteristics Model,,, /( /) / /(/ ) S-0 S-0 S-0 S-0 (,, ) C C0 C C (, ) C6 C C0 C C [dm /(s bar)] 0.9.. 6. b 0.6 0.0 0. 0.9 Cv 0. 0.6 0.9. C [dm /(s bar)]... 7.0 b 0. 0. 0. 0. Note) The value is for manifold base with stations and individually operated position type. 000 C, N, 0 C, C0, C N9, N, 0, 0 Cv 0. 0. 0.9.6 nclosure of Manifold Variations (Common for cassette base and tie-rod base) X00 ecentralized serial wiring X0 Serial wiring with input/output onit X0 edicated output serial wiring For circular connector -sub connector Flat ribbon cable nclosure of a gateway unit and input manifold is I6. -- nclosure (ased on IC9) I67 I67 usttight (I0) I67 usttight (I0) usttight (I0)

Valve Manifold Common Specifications Solenoid Valve Specifications Made to Order Specifications (For details, refer to page --0.) JIS Symbol position single solenoid () position double solenoid () () () () () () () () () position closed center () () () () () position exhaust center position pressure center position dual port valve: N.C./N.C. SOL.a position dual port valve: N.O./N.O. SOL.a () () () () () () () () position dual port valve: N.C./N.O. () () SOL.a () () () () () () () SOL.b () SOL.b () SOL.b () () () () () () Fluid Internal pilot Operating pressure range (Ma) xternal pilot Operating pressure range (Ma) Type of actuation position single position double position position single position dual port valve position double position Operating pressure range position single, double position position dual port valve or less or less Note) ased on dynamic performance test, JIS 7-9. (Coil temperature: 0 C, at rated voltage) ir 0. to 0.7 0. to 0.7 0. to 0.7 00 ka to 0.7 0. to 0.7 mbient and fluid temperature ( C) 0 to 0 (No freezing. efer to page -7-.) Max. operating position single, double frequency position dual port valve (Hz) position Manual override ilot exhaust method Lubrication Mounting orientation Non-locking push type ush-turn locking slotted type Not required Unrestricted Internal pilot Common exhaust type for main and pilot valve xternal pilot ilot valve individual exhaust Impact/Vibration resistance (ms ) nclosure Coil rated voltage llowable voltage fluctuation ower consumption Surge voltage suppressor Indiator light 0/0 I67 (ased on IC9) VC, VC ±0% of rated voltage 0.6 (With indicator light: 0.6) Zener diode L Note) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resisitance: No malfunction occured in a one-sweep test between and 000 Hz. Test was perfomed at both energized and deenergized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) esponse Time Weight Type of actuation Single solenoid ouble solenoid 000 position position dual port Single solenoid ouble solenoid 000 position position dual port Single solenoid 000 ouble solenoid position Single solenoid 000 ouble solenoid position Note) Weight of solenoid valve only. esponse time (ms) (at the pressure of 0. Ma) 000 or less 0 or less or less 000 or less 7 or less 9 or less 000 or less 6 or less or less 000 0 or less 0 or less or less Weight (g) 66 7 7 7 7 7 7 99 0 0 6 90 --

ecentralized Serial Wiring I67 compliant X00 Tie-rod base Cassette base pplicable series Cassette base manifold 000/000 Tie-rod base manifold 000/000/000/000 Number of output points: 6 points X00 gateway unit communication specifications emote I/O, evicenet, OFIUS- --7

X00 ecentralized Serial Wiring For details about certified products conforming to international standards, visit us at www.smcworld.com. Tie-rod base S Cassette base 000 000 000 000 W 0S W How to Order S W 6S W 0 Mounting Nil 0 6 0 U U irect mounting IN rail mounting (With IN rail) IN rail mounting (Without IN rail) For stations When a longer IN rail is desired than the specified stations. (Specify a For 6 stations longer rail than the standard length.) In the case of 0, only IN rail fittings are attached. Valve stations Symbol 0 0 0 6 Stations stations stations stations 6 stations 000 000 W W 0 Note ouble wiring specifications nclosure I67 specifications SI unit () Specified layout (up to 6 solenoids possible.) For emote I/O For evicenet/ For rofius- Without SI unit () Note ) ouble wiring specifications: Single, double, position and position solenoid valves can be used on all manifold stations. Use of a single solenoid will result in an unused control signal. If this is not desired, order with a specified layout. Note ) Specified layout: Indicate wiring specifications on the manifold specification sheet. (Note that double, position and position valves cannot be used where single solenoid wiring has been specified.) U IN rail length specified Nil Standard length For stations (Specify a longer rail than the standard 6 For 6 stations length.), port location U side ( to 0 stations) side ( to 0 stations) oth sides ( to 6 stations) SU/XH block assembly specifications Nil S S Internal pilot Internal pilot/uilt-in silencer xternal pilot xternal pilot/uilt-in silencer Note) When the built-in silencer type is used, keep the exhaust port from coming in direct contact with water or other liquids., port size (metric) Symbol, port C C C6 C C6 C C6 fitting for ø. fitting for ø fitting for ø6 fitting for ø fitting for ø6 fitting for ø fitting for ø6 C fitting for ø In the case of mixed C0 fitting for ø0 specifications (M), indicate separately on the manifold C fitting for ø specification sheet. C0 fitting for ø0 ort sizes of X, port for external pilot C 0 fitting for ø c / specifications (, S) are 0 c/ ø (metric), ø/" (inch) 0F G / for 000/000 and ø6 (metric) and ø/" (inch) 0F G / for 000/000. M, ports mixed --0, port pplicable series fitting for ø fitting for ø0 fitting ø fitting ø c / G / 000 000 000 000, port size (inch) Symbol N N N7 N N7 N9 N7 N9 N N9 N 0N 0N 0T 0T M, port fitting for ø/" fitting for ø/" fitting for ø/" fitting for ø/" fitting for ø/" fitting for ø/6" fitting for ø/" fitting for ø/6" fitting for ø/" fitting for ø/6" fitting for ø/" NT / NT / NTF / NTF /, ports mixed, port pplicable series fitting for ø/6" fitting for ø/" fitting for ø/" fitting for ø/" NT / NTF / 000 000 000 000

side X00 ecentralized Serial Wiring How to Order Valve Manifold ssembly Ordering example (000) Manifold S-W6SW-06-C6 ( set) ouble solenoid 00-FU ( sets) Single solenoid 00-FU ( sets) U side W COM S-W6SW-06-C6 set (Manifold part no.) 00-FU sets (Single solenoid part no.) 00-FU sets (ouble solenoid part no.) Stations How to Order Solenoid Valves 00 F Note) Note) vailable with manifold block for station additions. efer to pages --9 and --9. 000 000 000 000 Manual override Nil: Non-locking push type : ush-turn locking slotted type Type of actuation position single solenoid position double solenoid position closed center position exhaust center position pressure center position dual port valve: N.C./N.C. position dual port valve: N.O./N.O. position dual port valve: N.C./N.O. C position dual port valves are applicable to 000 and 000 only. ilot type Nil Internal pilot xternal pilot xternal pilot specifications is not available for position dual port valves. ack pressure check valve Nil None K uilt-in uilt-in back pressure check valve type is applicable to series 000 only. ack pressure check valve is not available for position closed center and position pressure ated voltage VC Light/Surge voltage suppressor U With light/surge voltage suppressor With surge voltage suppressor efer to recautions on page --9. --

Specifications Gateway (GW) unit Model X00-G-X pplicable LC/Communication protocol ockwell utomation, Inc. LC 7.6 Kbit/sec,. Kbit/sec Communication speed 0. Kbit/sec ated voltage ower supply voltage range Current consumption No. of input/output points No. of input/output branches ranch cable ranch cable length Communication connector ower connector mbient operating temperature/humidity nclosure pplicable standard Weight (g) X00-GN evicenet elease.0 Kbit/sec, 0 Kbit/sec 00 Kbit/sec VC X00-G OFIUS- 9.6/9./9.7/7./00 kbit/sec.//6/ Mbit/sec Input and control unit power supply: VC ±0% Solenoid valve power supply: VC +0%/ % (ower drop warning at approx. 0 V) Communication cables and connectors are sold separately. efer to options on page --7. 00 m or less Maximum 6 inputs/6 outputs branches (6 inputs/6 outputs per branch) core heavy duty cable m or less (total extension 0 m or less) M connector ( pins, Socket) M connector ( pins, lug) + to + C/ to % H (No condensation) I6 UL, CS, C 70 How to Order X00 G N Communication protocol N evicenet OFIUS- emote I/O (IO) pplicable GW unit evicenet Nil OFIUS- -X emote I/O (IO) imensions US UN SOL COM GTWY UNIT X00 SIS 6 7 X00-G-X VOLTG VC/00 m TY INUT/OUTUT 6/6 I CO I6 SIL NO. M IN JN VC COM COM COM C COM.6.6 6 0 6 60 7.9. --

C C C C C US TY C US TY C US TY (N) C C C C C C TY C US C C X00 ecentralized Serial Wiring How to Order Input Manifold Stations station How to Order Input lock Input unit X00 I X00 I manifold Input Unit Specifications Input unit specifications Connector type T M M connector M connector M, M mixed Current source type input block (N input block) Connection block or Current sink type input block (NN input block) Communication connector M connector ( pins, plug) Number of connection blocks Maximum blocks lock supply voltage VC lock supply current 0.6 maximum Current consumption 00 m or less (at rated voltage) Operates at Typ. (ower supply cut) Short circuit protection GW unit reset by turning power OFF and back ON. nclosure I6 Weight (g) Note) 00 (Input block + nd lock) Note) Since the IN rail weight is not included, confirm the IN rail length to be used on page --, and add the weight separately which is found in the IN rail dimension table on page --97. stations pplicable GW unit evicenet Nil OFIUS- -X emote I/O (IO) How to Order Input Unit Manifold [Ordering example] lock type 6 Input lock Specifications Sensor applicable Sensor connector Number of inputs ated voltage Indication Insulation Sensor supply current nclosure Weight (g) M connector, N specifications M connector, NN specifications M connector, N specifications M connector, NN specifications points integrated type, M connector, N specifications points integrated type, M connector, NN specifications pplicable GW unit evicenet Nil OFIUS- -X emote I/O (IO) Current source type (N output) or Current sink type (NN output) M connector ( pins) or, M connector ( pins) inputs/ inputs (M only) VC Green L None Maximum 0 m/sensor I6 [For M: 0] [For M: 0] [ points integrated type, for M: ] When ordering an input unit manifold, enter the Input manifold part no. + Input block part no. together. The Input unit, nd block and IN rail are included in the input manifold. efer to the indications below. lock part no. entry Unit side nd block side xample ) M input block only Unit side X00-I VOLTG VC/60 m INUT 6 I CO I6 SILNo. M IN JN TY US X00-I (N) VOLTG VC/0 m I CO I6 SILNo. M IN JN TY US Input manifold X00-I- ( set) X00-I (N) VOLTG VC/0 m I CO I6 SILNo. M IN JN TY US Input block X00-I ( sets) X00-I- set X00-I sets nd block side xample ) M input block only Unit side X00-I VOLTG VC/60 m INUT 6 I CO I6 TY SILNo. M IN JN X00-I (N) VOLTG I CO TY US I6 VC/60 m M IN JN X00-I (N) VOLTG I CO TY US I6 VC/60 m M IN JN X00-I (N) VOLTG I CO TY US I6 VC/60 m M IN JN Input manifold X00-I-T ( set) X00-I (N) VOLTG I CO TY US I6 VC/60 m M IN JN Input block X00-I ( sets) X00-I-T set X00-I sets nd block side Unit side X00-I VOLTG VC/60 m INUT 6 I CO I6 SILNo. M IN JN Unit side X00-I VOLTG VC/60 m INUT 6 I CO I6 SIL No. M IN JN C US TY TY US X00-I (N) VC/60 m/i6 X00-I (N) VC/60 m/i6 M IN JN M IN JN M IN JN X00-I (N) VOLTG VC/0 m I CO I6 SILNo. M IN JN X00-I (N) VC/60 m/i6 X00-I X00-I X00-I X00-I X00-I (N) (N) (N) (N) M IN JN M IN JN M IN JN M IN JN M IN JN TY US VC/60 m/i6 VC/60 m/i6 VC/60 m/i6 VC/60 m/i6 C US C US C US C US TY TY TY TY X00-I (N) VC/60 m/i6 C US TY Input manifold X00-I- ( set) X00-I (N) VC/60 m/i6 C US TY M IN JN M IN JN VC/60 m/i6 TY C US Input block X00-I ( sets) X00-I- set X00-I sets nd block side Input manifold X00-I-6 ( set) Input block X00-I ( set) Input block X00-I ( sets) X00-I-6 set X00-I set X00-I sets nd block side xample ) M and M mixed Unit side X00-I VOLTG VC/60 m INUT 6 I CO I6 TY SILNo. M IN JN C US X00-I (N) VC/60 m/i6 TY C US M IN JN X00-I (N) VC/60 m/i6 TY C US M IN JN X00-I (N) VC/60 m/i6 TY C US M IN JN X00-I (N) VOLTG I CO TY US I6 VC/60 m M IN JN Input manifold X00-I-M6 ( set) Input block X00-I ( sets) X00-I (N) VOLTG I CO TY US I6 VC/60 m M IN JN Input block X00-I ( sets) X00-I-M6 set X00-I sets X00-I sets nd block side Note) Since the point integrated type input block is equivalent to the length of four stations on an M input block, pay attention to the number of stations on an input manifold. When an input block layout becomes complicated, indicate on the input unit manifold specification sheet. --

Input Unit Manifold xploded View w a q e r a t y Component arts No. escription art no. For standard For IO Note q w e r Input unit Input block (M connector) Input block (M connector) input block (M connector) X00-I X00-I X00-I X00-I X00-I-X X00-I -X X00-I -X X00-I -X N specifications :, NN specifications : N specifications :, NN specifications : N specifications :, NN specifications : 6 t y nd block IN rail X00- VZ000--- : Length (efer to page --97.) How to add input block stations () Loosen the screws a ( places) that hold the end block. () Separate the blocks at the locations where stations are to be added. () ttach the additional blocks to the IN rail, and connect the blocks so that they fit together securely. () While holding the blocks together so that there are no gaps between them, secure them to the IN rail by tightening the screws a. Note: e sure to tighten the round head combination screw with the prescribed tightening torque. (0.6 N m) --

VOLTG INUT I CO SIL NO. VC/60 m 6 I6 M IN JN X00-I (N) VOLTG VC/60 m I CO I6 C US M IN JN X00-I (N) VOLTG VC/60 m I CO I6 M IN JN C US C US M IN JN M IN JN X00-I (N) VOLTG VC/60 m I CO I6 M IN JN C US M IN JN X00-I (N) VOLTG VC/60 m I CO I6 M IN JN C US M IN JN C US M IN JN X00-I (N) VOLTG VC/60 m I CO I6 M IN JN C US M IN JN X00-I (N) VOLTG VC/60 m I CO I6 M IN JN C US M IN JN C US M IN JN X00-I (N) VOLTG VC/60 m I CO I6 M IN JN X00-I (N) VOLTG VC/60 m I CO I6 M IN JN X00 ecentralized Serial Wiring Input Unit Manifold imensions Input block (M) only 7 (itch) = IN rail. 9 L L (ail mounting pitch:.) L (L). X00-I VOLTG VC/60 m INUT 6 I CO I6 SIL NO. C TY US X00-I (N) VC/60 m/i6 TY X00-I (N) VC/60 m/i6 TY X00-I (N) VC/60 m/i6 TY X00-I (N) VC/60 m/i6 TY X00-I (N) VC/60 m/i6 TY X00-I (N) VC/60 m/i6 TY X00-I (N) VC/60 m/i6 TY X00-I (N) VC/60 m/i6 TY (7.) 9.7. M IN JN (mm) Stations ail length L Mounting pitch L Manifold length L L 9 7. 7 0. 00 6. 9.. 0. 7. 6 60. 0 7 7 6. 6.. 7. Input block (M) only 7 (itch) = 0 IN rail 60. L L (ail mounting pitch:.) L (L). X00-I C TY US TY C TY US C TY US C TY US C TY US C TY US C TY US C TY US (7.). 6.9 (mm) Stations ail length L Mounting pitch L Manifold length L L 0. 00. 0 7.. 7 6... 7 6 6 0. 00 7. 0. 7.. --

For valve specifications, refer to page --. How to Order SI Unit X00 S00 Specifications pplicable GW unit evicenet Nil OFIUS- -X emote I/O (IO) Connection block Communication connector Solenoid valve (Single, ouble) elay output module ( output, outputs) M connector ( pins, lug, Socket) Option Connection block stations ouble solenoid valve elay output module ( points): Maximum stations Single solenoid valve elay output module ( point): Maximum 6 stations lock supply voltage VC lock supply current 0.6 maximum Current consumption 00 m or less (at rated voltage) nclosure Note) I6 Weight (g) Note) single SI unit of X00 has an enclosure compliant with I6. The I67 protection can be achieved when it is mounted on a manifold. () Terminal plug () () Communication connector (6) Waterproof cap (6) Waterproof cap (6) Waterproof cap () ower cable with connector () Cable with M connector --6

X00 ecentralized Serial Wiring Option () Communication connector (For IO type GW unit) X00 C000 M ø. () Communication connector cable (For evicenet type GW unit) X00 C 00 N Cable length (l) 00 00 000 mm 000 mm M ø.9 ø.9 0.7. ø7 l pplicable cable size ø6 (ø to ø6) 0 Socket connector pin arrangement Terminal no. Core wire colors :IN ed: V+ lack: V White: CN H lue: CN L Connections () Cable with M connector X00 C 00 SSS Cable length (l) 00 00 00 00 00 00 mm 00 mm 000 mm 000 mm 000 mm Connector specifications SSS S Socket side: Straight, lug side: Straight Socket side: ngle, lug side: ngle M l ø6 ø6 M. ø6 M. ø.9 M.. l Terminal no. Core wire colors Terminal no. Core wire colors White White rown rown 7 Green 7 7 Green 7 Yellow Yellow Gray Gray 6 6 6 ink 6 6 6 6 ink 6 7 7 lue 7 7 lue Shield Shield Socket connector lug connector Socket connector lug connector pin arrangement Connections pin arrangement pin arrangement Connections pin arrangement Straight connector type ngle connector type --7

Option () ower cable with connector X00 00 S Cable length (l) 00 00 000 mm 000 mm Connector specifications S Straight ngle M M ø6. ø6 ø.9 l 0 0. l 0 0 Socket connector pin arrangement Socket connector pin arrangement Terminal no. Core wire colors Terminal no. Core wire colors rown: 0 V (Solenoid valve power supply) White: VC +0%/ % (Solenoid valve power supply) lue: 0 V (Input and control power supply) lack: VC ±0% (Input and control power supply) Gray: rown: 0 V (Solenoid valve power supply) White: VC +0%/ % (Solenoid valve power supply) lue: 0 V (Input and control power supply) lack: VC ±0% (Input and control power supply) Gray: Connections Straight connector type Connections ngle connector type () Terminal plug This is used where an input manifold (input unit/input block) is not being used. (If a terminal plug is not used, the GW unit is COM L will not light up. ) X00 C000 S (6) Waterproof cap Use this on ports that are not being used for a GW unit or input block. Use of this waterproof cap maintains the integrity of the I6 enclosure. (Included with each input block.) Note) Tighten the waterproof cap with the prescribed tightening torque. (For M: 0.0 N m, For M: 0. N m) X00 W 7 6 lug connector pin arrangement ø6 M.7 Connector type S T TS M connector (For socket) M connector (For plug) M connector (For socket) Waterproof cap --

X00 ecentralized Serial Wiring imensions: 000 for X00 ecentralized Serial Wiring U C6, N7 C, N9 C0, N Tie-rod base manifold: S-W0S W- Stations (S,, S) - (-) When, port outlets are indicated on the U side or side, the, ports on the opposite side are plugged. xternal pilot port positions and silencer discharge port positions are the same as, port outlet positions.. 6. fitting [(), /() port] pplicable tubing O..: ø ø/" IN rail holding screw (For IN rail mounting) U side 6.. (.) (itch) = 0. L L. -M fitting [(), () port] pplicable tubing O..: ø6, ø/" ø, ø/6" ø0, ø/" side (L) (.).6.6 C C..6 6 7.6 9. With xternal ilot Specifications 60. 76. fitting [X: xternal pilot port] pplicable tubing O..: ø6 ø/" X X fitting [: ilot XH port] pplicable tubing O..: ø6 ø/" C C SI unit... 6.9. 9.6 -ø. (For mounting) Light/Surge voltage suppressor Manual override (ress and turn for the locking type.) () port side: Orange () port side: Green L (ail mounting hole pitch:.) L (Station n) (Station ) W COM. 0. 6. 9. Silencer (ir discharge port) (uilt-in silencer specifications) With option 0.. / / 60.9. 9.7 0.7.7 6. 7 Individual SU spacer Individual XH spacer Interface regulator 000-M- Interface regulator 000-00- MX..7 (For IN rail mounting) (0) 9.9 7.9 L imension L n L L L L L 60. 0.. 97. 7.6 7. 0. 00 76. 7. 96.6. 6 7. 7.. 79 7 7 6. 7.6 7. 99.. 7.. 0 9 0. 00 7.6 6 0. 0. 99. 6 7. 9.6. 7 6. 0. 6. 0. 7 60.6.. 0. 00... 0.6 7 6. n: Stations 6 7.. --

Serial Wiring with Input/Output Unit I67 compliant X0 Tie-rod base pplicable series Tie-rod base manifold 000/000/000 Number of inputs/outputs: each --

X0 Serial Wiring with Input/Output Unit For details about certified products conforming to international standards, visit us at www.smcworld.com. Tie-rod base nclosure I67 specifications How to Order S W0S QW 0 000 000 000 SI unit QW 0 For evicenet Without SI unit Input blocks cannot be mounted without SI unit. When the IN rail is included without an SI unit, the IN rail length will accommodate an SI unit and one input block. Input block type Nil Without input block M: inputs M: inputs M: inputs ( pins) Note) Without SI unit, the symbol is nil. Input block stations Nil None station stations Note) Without SI unit, the symbol is nil. Input block common specifications Nil N +COM COM U Nil 0 0 Mounting irect mounting IN rail mounting (With IN rail) IN rail mounting (Without IN rail) For stations When a longer IN rail is desired than the specified stations. (Specify a longer For 0 stations rail than the standard length.) In the case of 0,only IN rail fittings are attached. Valve stations Symbol 0 6 0 0 Stations stations 6 stations stations 0 stations Note ouble wiring specifications () () Specified layout (up to solenoids possible.) Note ) ouble wiring specifications: Single, double, position and position solenoid valves can be used on all manifold stations. Use of a single solenoid will result in an unused control signal. If this is not desired, order with a specified layout. Note ) Specified layout: Indicate wiring specifications on the manifold specification sheet. (Note that double and position valves cannot be used where single solenoid wiring has been specified.), port location U U side ( to 0 stations) side ( to 0 stations) oth sides ( to 0 stations) SU/XH block assembly specifications Nil Internal pilot S Internal pilot/uilt-in silencer xternal pilot S xternal pilot/uilt-in silencer Note) When the built-in silencer type is used, keep the exhaust port from coming in direct contact with water or other liquids. --6, port size (metric) Symbol, port C fitting for ø. C fitting for ø C6 fitting for ø6 C fitting for ø C6 fitting for ø6 C fitting for ø C6 fitting for ø6 C fitting for ø C0, port pplicable series fitting for ø fitting for ø0 000 000, port size (inch) Symbol, port N fitting for ø/" N fitting for ø/" N7 fitting for ø/" N fitting for ø/" N7 fitting for ø/" N9 fitting for ø/6" N7 fitting for ø/" N9 fitting for ø/6" N fitting for ø/", port pplicable series fitting for ø/6" fitting for ø/" 000 000 000 000 fitting for ø fitting for ø/" fitting for ø0 M, ports mixed M, ports mixed In the case of mixed specifications (M), indicate separately on the manifold specification sheet. ort sizes of X, port for external pilot specifications (, S) are ø (metric), ø/" (inch) for 000/000 and ø6(metric) and ø/" (inch) for 000/000.

side X0 Serial Wiring with Input/Output Unit How to Order Valve Manifold ssembly Ordering example (000) Manifold S-W0SQWN-0-C6 ( set) U side Stations ouble solenoid 00-FU ( sets) Single solenoid 00-FU ( sets) Input block (M: inputs, station) S-W0SQWN-0-C6 set (manifold part no.) 00-FU sets (Single solenoid part no.) 00-FU sets (ouble solenoid part no.) How to Order Solenoid Valves 00 F Note) Note) vailable with manifold block for station additions. efer to page --9. 000 000 000 Manual override Nil: Non-locking push type : ush-turn locking slotted type Type of actuation position single solenoid position double solenoid position closed center position exhaust center position pressure center position dual port valve: N.C./N.C. position dual port valve: N.O./N.O. C position dual port valve: N.C./N.O. position dual port valves are applicable to 000 and 000 only. ilot type Nil Internal pilot xternal pilot xternal pilot specifications is not available for position dual port valves. ated voltage VC Light/Surge voltage suppressor U With light/surge voltage suppressor With surge voltage suppressor ack pressure check valve Nil None K uilt-in uilt-in back pressure check valve type is applicable to series 000 only. ack pressure check valve is not available for position closed center and position pressure center. efer to recautions on page --9. --7

X0 Serial Wiring with Input/Output Unit pplicable network: evicenet The serial transmission system reduces wiring work, while minimizing wiring and saving space. 000/000/000 evicenet compatible SI unit s a evicenet slave unit, it is capable of solenoid valve ON/OFF control up to a maximum of points. In addition, by connecting an input block a maximum of sensor signal inputs are possible. Input block This is an expansion block which connects to an SI unit to perform sensor input from auto switches, etc. Two or four sensor inputs can be accommodated by one input block, and the common can be matched to the sensor by an NN/N switch. Note) Input connectors are available in both M and M types. Note) COM is set at the shipment. lease contact SMC for alteration after shipment. etails in connector Input connector: M pins (socket) Cable side connector example: OMON Corporation: XSG input block (X0-I) No. escription Function SW+ N.C (SIGNL) SW SIGNL Sensor power supply + Open Sensor power supply Sensor input signal Sensor ground In the case of a input block (X0-I), this is the sensor input signal. Communication connector: M... pins (socket) xample of corresponding cable assemblies with connector: OMON Corporation: C-CN0F Karl Lumberg GmbH & Co. KG: KT-6 No. escription rain V+ V CN_H CN_L Function rain/shield Circuit power supply + Circuit power supply Signal H Signal L 0 0 0 0 US W / Indicator unit (L) descriptions and functions SI unit Input block Input connector: M pins (socket) Cable side connector example: Franz inder GmbH: 7, 76 series No. escription Function V Sensor power supply + 0V Sensor power supply IN Sensor input signal W(V) W MO/NT 6 STTINGS W 6 X0 escription W(V) W MO/NT escription W 0 to ower connector: M pins (plug) (boss configuration differs from communication connector) xample of corresponding cable assemblies with connector: Hans Turck FmbH & Co. KG: WKW. T- No. escription V 0V SWV SW0V Function Function For solenoid valve + V For solenoid valve 0 V For input block + V For input block 0 V Ground ON when solenoid valve power supply is turned ON ON when evicenet circuit power supply input is turned ON OFF: ower supply off, on line, or when checking duplication of MC_I Green blinking: Waiting for connection (On line) Green ON: Connection established (On line) ed blinking: Connection time out (Minor communication abnormality occurs) ed ON: MC_I duplication error, or USOFF error (Major communication abnormality occurs) Weight Function escription weight (g) ON when sensor power is turned ON SI unit ON when each sensor input goes ON Input block nd plate assembly 0 For parts composition, refer to page --90. X0 --

X0 Serial Wiring with Input/Output Unit imensions: 000 for X0 Serial Wiring with Input/Output Unit Tie-rod base manifold: S-W0S - Stations (With input blocks) U (S,, S) - C6, N7 C, N9 C0, N (-) When, port outlets are indicated on the U side or side, the, ports on the opposite side are plugged. xternal pilot port positions and silencer discharge port positions are the same as, port outlet positions. 7.6 6. fitting [(), /() port] pplicable tubing O..: ø ø/" IN rail holding screw (For IN rail mounting).....6 -ø. (For mounting) U side. 6.9 9.6 (itch).. = 0. (.) Ground terminal -M fitting -M [(), () port] pplicable tubing O..: ø6, ø/" ø, ø/6" ø0, ø/" Silencer (ir discharge port) (uilt-in silencer specifications) L (L) side L6 L7. IN rail holding screw (For IN rail mounting) SI unit Input block (.) 6. 6. Manual override ress and turn for the ( locking type. ) () port side: Orange () port side: Green L 6 L (ail mounting hole pitch:.) L T W US 6 6 7.7..7 66 6. With xternal ilot Specifications. 60. 76. fitting [X: xternal pilot port] pplicable tubing O..: ø6 nd plate assembly -M mounting hole X X With option W US 6 fitting [: ilot XH port] pplicable tubing O..: ø6 ø/" ø/" T 6 (Station n) (Station ) Light/Surge voltage suppressor (Station ) (Station n) 0.. / / 60.9. 9.7 0.7.7 6. 60 Individual SU spacer Individual XH spacer Interface regulator 000-M- Interface regulator 000-00- MX. L: IN ail Overall Length Valve stations (n) Input block Stations(n) 0 6 7.7 (For IN rail mounting) 60.. 0. 7. 60.. 0. 7. 0. 60.. 0. 7. 0... 0. 7. 0.. 6 9 7. 0.. 7 7 60.. 0.. 7 9 60.. 0. 7 9 0. L = L 0. L = 0. x n + 70. L = L + + x n L = (L L)/ L6 = 0. x n + 6 L7 = x n +. 9 60.. 0. 7. 0.. (0) n = Valve stations n = Input block stations 0. 0. 7. 0.. 0. 7. 0.. 7 7. 0.. 7 9 7. 0.. 7 9 60. 7. 0.. 7 9 60. 6.. 0.. 7 9 60. 6. 660. 6 0.. 7 9 60. 6. 660. 67 7. 7 9 60. 6. 660. 67 69 7 9 60. 6. 660. 67 69 7 9.9 7.9 9 7. 60. 6. 660. 67 69 7 7. (mm) 0. 60. 6. 6 67 69 7 7. 760. --

edicated Output Serial Wiring X0 Tie-rod base Cassette base pplicable series Cassette base manifold 000/000 Tie-rod base manifold 000/000/000/000 Number of outputs points: 6 points --

X0 edicated Output Serial Wiring For details about certified products conforming to international standards, visit us at www.smcworld.com. Tie-rod base Cassette base SI unit C F G H J J K Q U V 000 000 S 000 000 000 000 How to Order S 6S 0 Symbol Specifications 0 Without SI unit With general type SI unit ( X00) Mitsubishi lectric Corp.: MLSCNT/MINI-S ata Link System OMON Corp.: SUS Wire System SH Corp.: Satellite I/O Link System Matsushita lectric Works: MWNT-F System NK Corp.: Uni-wire System (6 output points) For the general purpose type, a transmission unit is require on the CU side. -- ockwell utomation: llen radley emote I/O (IO) System NK Corp.: Uni-wire H System SUNX Corp.: S-LINK System (6 output points) SUNX Corp.: S-LINK System ( output points) Fuji lectric Co.: T-LINK Mini System evicenet, Compous/ (OMON Corp.) OMON Corp.: Compous/S System (6 output points) OMON Corp.: Compous/S System ( output points) JMNT (JCN-) Mitsubishi lectric Corp.: CC-LINK System SI Unit art No. Valve stations Symbol Stations Note 0 stations () ouble wiring specifications 0 stations 0 stations () Specified layout 6 6 stations (up to 6 solenoids possible.) Since J and type SI units have outputs note that up to solenoids can be accommodated. This also includes the number of blanking plate assemblies. Note ) ouble wiring specifications: Single, double, position and position solenoid valves can be used on all manifold stations. Use of a single solenoid will result in an unused control signal. If this is not desired, order with a specified layout. Note ) Specified layout: Indicate wiring specifications on the manifold specification sheet. (Note that double and position valves cannot be used where single solenoid wiring has been specified.), port location 0S U 0 U U U side ( to 0 stations) side ( to 0 stations) oth sides ( to 6 stations) Mounting Nil 0 irect mounting IN rail mounting (With IN rail) IN rail mounting (Without IN rail) For stations When a longer IN rail is desired than the specified stations. (Specify a 6 For 6 stations longer rail than the standard length.) IN rail length specified Nil Standard length For stations (Specify a longer rail than the standard 6 For 6 stations length.) SU/XH block assembly specifications Nil S S Internal pilot Internal pilot/uilt-in silencer xternal pilot xternal pilot/uilt-in silencer Symbol Specifications With general type SI unit ( X00) For S - S X0-S00 Symbol H Specifications NK Corp.: Uni-wire H System Mitsubishi lectric Corp.: J SUNX Corp.: S-LINK System (6 output points) X0-SM MLSCNT/MINI-S ata Link System J SUNX Corp.: S-LINK System ( output points) C F OMON Corp.: SUS Wire System SH Corp.: Satellite I/O Link System Matsushita lectric Works: MWNT-F System NK Corp.: Uni-wire System (6 output points) X0-ST X0-SSH X0-S X0-SUW K Q Fuji lectric Co.: T-LINK Mini System evicenet, Compous/ (OMON Corp.) OMON Corp.: Compous/S System (6 output points) OMON Corp.: Compous/S System ( output points) G ockwell utomation: U JMNT (JCN-) X0-S llen radley emote I/O (IO) System V Mitsubishi lectric Corp.: CC-LINK System For terminal L descriptions for each SI unit and cable wiring, etc., refer to pages --6 to --. In the case of 0, only IN rail fittings are attached. For S - S X0-SUH X0-SSL X0-SSL X0-SFU X0-SN X0-SCS X0-SCS X0-SJN X0-SMJ

X0 edicated Output Serial Wiring How to Order Valve Manifold ssembly Ordering example (000) Manifold S-6S-06-C6 ( set) ouble solenoid 00-FU ( sets) Single solenoid 00-FU ( sets) U side Stations 00 000 000 000 000 Type of actuation position single solenoid position double solenoid position closed center position exhaust center position pressure center position dual port valve: N.C./N.C. position dual port valve: N.O./N.O. C position dual port valve: N.C./N.O. position dual port valves are applicable to 000 and 000 only. side ilot type Nil Internal pilot xternal pilot xternal pilot specifications is not available for position dual port valves. How to Order Solenoid Valves S-6S-06-C6 set (manifold part no.) 00-FU sets (Single solenoid part no.) 00-FU sets (ouble solenoid part no.) F ated voltage VC ack pressure check valve Note) vailable with manifold block for station additions. efer to pages --9 and --9. Manual override Nil: Non-locking push type : ush-turn locking slotted type Light/Surge voltage suppressor U With light/surge voltage suppressor With surge voltage suppressor Nil None K uilt-in uilt-in back pressure check valve type is applicable to 000 only. ack pressure check valve is not available for position closed center and position pressure center. efer to recautions on page --9. Note), port size (Metric) Symbol, port C fitting for ø. C fitting for ø C6 fitting for ø6 C fitting for ø C6 fitting for ø6 C fitting for ø C6 fitting for ø6 C fitting for ø C0 fitting for ø0 C fitting for ø C0 fitting for ø0 C fitting for ø 0 c / 0 c / 0F G / 0F G /, port pplicable series fitting for ø fitting for ø0 fitting for ø fitting for ø c / G / 000 000 000 000, port size (Inch) Symbol N N N7 N N7 N9 N7 N9 N N9 N 0N 0N 0T 0T M, port fitting for ø/" fitting for ø/" fitting for ø/" fitting for ø/" fitting for ø/" fitting for ø/6" fitting for ø/" fitting for ø/6" fitting for ø/" fitting for ø/6" fitting for ø/" NT / NT / NTF / NTF /, port pplicable series fitting for ø/6" fitting for ø/" fitting for ø/" fitting for ø/" NT / NTF /, ports mixed 000 000 000 000 M, ports mixed In the case of mixed specifications (M), indicate separately on the manifold specification sheet. ort sizes of X, port for external pilot specification (, S) are ø (metric), ø/" (inch) for 000/000 and ø6 (metric) and ø/" (inch) for 000/000. --

The serial transmission system reduces wiring work, while minimizing wiring and saving space. Maximum 6 stations (Specify a model with more than 9 stations by means of the manifold specification sheet.) Type X00 Type Mitsubishi lectric Corporation MLSCNT/MINI-S ata Link System STTION NO. U side Stations side Stations are counted from side as the st. maximum of 6 solenoids is possible (6 stations with single solenoids). Item Specifications xternal power supply VC + 0%/ %,,,, F, G, J, Current consumption 0. J, K,,, H, U, V (Internal unit) 0. C, Q Name of terminal block, L Note V 0 V S S SG L T UN/ UN T SS NO. escription ON during data reception links for normal data reception, ON for abnormal Connection to T unit LC manufacturer s I/O card enables serial transmission. X00-TM for Mitsubishi lectric Corporation X00-TT for OMON Corporation X00-TFU for Fuji lectric Co., Ltd. X00-T00 General purpose ach T unit has control points. No. of output points, 6 points L OW UN S OWUNS x 0 x V 0 V S S SG escription ON for power supply input ON for normal data traffic with master unit ON during data reception ON during data transmission ON for data reception error, OFF when normal MLSCNT/MINI-S ata Link System Master unit : J7T-S J7T-S SJ7T-S No. of output points, 6 points, No. of stations. occupied, stations SI manifold solenoid valve T unit O unit SI unit SI unit Master unit emote I/O unit emote I/O unit Cable wiring S S SG V 0 V S S SG V 0 V S S SG V 0 V S S SG V 0 V S S SG S S SG S S SG Ground either the reception side or the transmission side of the shielding wire shield. Ground either the reception side or the transmission side of the shielding wire shield. Type C OMON Corporation SUS Wire System Type SH Corporation Satellite I/O Link System Type Matsushita lectric Works, Ltd. MWNT-F System Name of terminal block, L L UN T/ UN T/ 6 I SW. V 0 V + - + - escription ON when transmission is normal and LC is in operation mode links when transmission is normal, ON when transmission is abnormal. L OW UN.ST HOL OW UN.ST HOL SS NO. TM. V 0 V L L SG L L V 0 V + - + - escription ON when power supply is ON ON when power is ON and slave unit operates normally ON for abnormal slave unit switch setting, abnormal communication, master unit LC stopped and defective slave unit ON for master unit control input L OW COMM. LM OW COMM. LM STSTION NO. TM. x 0 x OFF ON escription ON when power supply is ON links during data transmission/reception ON for unit abnormality, blinks for station no. setting error Note SUS Wire System Master unit : Type C00-M0 Type C00H-M0 No. of output points, 6 points Satellite I/O Link System JW-LM, JW-LMH Master unit : ZW-LM JW-LM, JW-LMH No. of output points, 6 points MWNT-F System Master unit : F70, F7 F70, F7 No. of output points, 6 points Master unit SI unit SI unit a) -wire type Wiring does not include signal ground line (SG). ZW-LM Master unit Slave unit 0 Slave unit 0 Slave unit 7 L L L L Master unit SI unit SI unit Cable wiring + + + V 0 V Type ground + + V 0 V Type ground L L SG SG SHIL SHIL Twisted pair wire with shield L L SG SG SHIL SHIL Type ground Type ground Type ground Type ground b) -wire type Wiring does not include signal ground line (SG). ZW-LM Master unit Slave unit 0 Slave unit 0 Slave unit 7 L L L L L L L L SG SG SG SG SHIL SHIL SHIL SHIL Twisted pair wire with shield Type ground Type ground Type ground Type ground + + + + V 0 V Type ground + + V 0 V Type ground --6

X0 edicated Output Serial Wiring Type F NK Corporation Uni-wire System Type G ockwell utomation, Inc. llen radley emote I/O (IO) System Type J, J SUNX Corporation S-LINK System Name of terminal block, L Note L OW SN OW V 0 V G G V 0 V V 0 V L L SHIL L L G 0 V V G 0 V V Uni-wire System Send unit : S-0 SN SS escription ON for power supply input (ON when normal, flickers when voltage drops) Transmission indication: links when normal, OFF or ON when abnormal No. of output points, 6 points ON OFF L OW COM O OW SN escription ON when power supply is ON ON when communication is normal links when communication is initialized OFF for abnormal communication ON for abnormal communication emote I/O (IO) System SS No. of output points, 6 points ON OFF L OW SN OW SN escription ON for power supply input Transmission indication: links when normal, links slowly when abnormal S-LINK System S-LINK controller: SL-CU I SW. No. of output points, 6 points (Type J) No. of output points, points (Type J) 6 Cable wiring Transmission line G ower supply ower supply V 0 V V 0 V ower supply V 0 V ower supply V 0 V V 0 V G G V 0 V V 0 V G G V 0 V Master unit LIN LIN SHIL SI unit L L SHIL L L V 0 V Type ground SI unit L L SHIL L L V 0 V Type ground Terminal resistor a) Type T branching multi-drop wiring (S-LINK System) lack White G Main transmission line 0 V V G0 V V rown lue Crimped connector SL-J b) Crossover wiring (Sensor Link System) G0V V G0V V Transmission line G The above is the example of using dedicated S-LINK flat ribbon cable SL-CMl00. Type K Fuji lectric Co., Ltd. T-LINK Mini System Type Q evicenet Type, OMON Corporation Compous/S STTION NO. W MO/NT STTINGS Name of terminal block, L L L OW LM OW LM TM. x 0 x ON OFF V 0V S S S S S escription ON for power supply input ON for abnormal transmission or processor side power supply cut L W MO/ NT 6 V 0 V V- CNL CNH V+ escription Green light ON for evicenet circuit power input OFF When this unit is off line or circuit power is OFF Green blinks When waiting for connection (On line) Green ON When connection is established (On line) ed blinks ed ON When connection time out occurs (recoverable communication abnormality) For MC I duplication error, or USOFF error (major communication abnormality) L W COMM W SS NO. COMM 6 S+ H L S- V 0 V escription ON when communication power is supplied, OFF when power is OFF ON for normal communication, OFF for abnormal communication or waiting ON for abnormal communication, OFF for normal communication or waiting Note T-LINK Mini System Master unit : FTM00 Converter : FC00-G0 epeater : FC00-C0 No. of output points, 6 points evicenet OMON Corporation: Compous/ System Master unit : Type C00HW-M-V Master unit : Type CSW-M No. of output points, 6 points Compous/S System Master unit : Type C00HW-SM-V Master unit : Type CQM-SM-V No. of output points, 6 points (Type S) No. of output points, points (Type S) V 0 V V CNL CNH V + V 0 V V CNL CNH V + S + H L S V 0 V S + H L S V 0 V Cable wiring Master unit Slave unit 0 Slave unit 0 Slave unit 7 S S S S S S S S S S S S Twisted pair wire with shield Type ground Type ground Type ground Type ground Connect the shielding wire to the S terminal. If the shielding wire is not connected to the S terminal, normal transmission will be impossible even for short distances. Furthermore, do not ground the shielding wire (S). V CNL CNH V + Master H L Connector with terminal resistor ranch crimped connectors --7

6 7 O N 7 7 7 Type H NK Corporation Uni-wire H System Type U JMNT (JCN-) Type V Mitsubishi lectric Corporation CC-LINK System Name of terminal block, L L OW SN OW SN ON OFF SS V 0V G G V 0V escription ON for power supply input (ON when normal, flickers when voltage drops) Transmission indication: links when normal, OFF or ON when abnormal L OW COMM LM OWCOMM LM V 0V SG V 0V ON I.SW 6 escription ON for SI unit power supply input On for normal communication ON for abnormal communication L W L UN S L. L. W S LUN T 6 9 6 9 6 STTION NO. 6 6 V 0V +V G G escription ON when communication power is supplied, OFF when power is OFF ON when normal data is being received ON when data is transmitted ON when data is received ON for transmission error/wrong setting, links when station or transmission speed setting changes during operation 9 6 x 0 x Note Uni-wire H System Send unit: S-H No. of output points, 6 points JMNT (JCN-) (eference) J7J9-S (Mitsubishi lectric Corporation) SJ7J9-S (Mitsubishi lectric Corporation) Type C00HW-JM (OMON Corporation) NJ-JCN- (Fuji lectric Co., Ltd.) NL-J (Fuji lectric Co., Ltd.) No. of output points, 6 points CC-Link System Master unit : J6T Master unit : SJ6T Master unit : J6QT Master unit : SJ6QT No. of output points, 6 points G a) -wire type Cable wiring Transmission line ower supply ower supply ower supply ower supply V 0 V V 0 V V 0 V V 0 V V 0 V G G V 0 V V 0 V G G V 0 V Master station SG b) -wire type Master station SG Slave unit (S unit) SG Twisted pair wire with shield Slave unit (S unit) SG Twisted pair wire with shield Slave unit (S unit) SG Slave unit (S unit) SG Slave unit (S unit) SG Slave unit (S unit) SG Terminal resistor Master unit SI unit SI unit G G G SL Twisted pair wire with shield Type ground Type ground Terminal resistor Type ground G --

X0 edicated Output Serial Wiring imensions: 000 for X0 edicated Output Serial Wiring Tie-rod base manifold: S-0S - Stations (S,, S) - U C6, N7 C, N9 C0, N (-) When, port outlets are indicated on the U side or side, the, ports on the opposite side are plugged. xternal pilot port positions and silencer discharge port positions are the same as, port outlet positions. 7.6 6...6 fitting [(), /() port] pplicable tubing O..: ø ø/" U side IN rail holding screw (For IN rail mounting) (itch).. = 0. (.) fitting [(), () port] pplicable tubing O..: ø6, ø/" ø, ø/6" ø0, ø/" L. L (.) side (L) With xternal ilot Specifications 60. 76. fitting [X: xternal pilot port] pplicable tubing O..: ø6 ø/" X fitting [: ilot XH port] pplicable tubing O..: ø6 ø/" X.... 6.9 9.6. 6 M Terminal screw 6. -ø. (For mounting) Light/Surge voltage suppressor.7 6. Manual override ress and turn for the ( locking type. ) () port side: Orange () port side: Green L (ail mounting hole pitch:.) L (Station n) (Station ) 77.. Silencer (ir discharge port) (uilt-in silencer specifications) With option 0.. / Individual SU spacer Individual XH spacer / Interface regulator 000-M- 60.9. 9.7 0.7 Interface regulator 000-00- MX..7 (For IN rail mounting) (0) 9.9 7.9 L imension L n L L L L L. 7. 7. 97 9 7.. 7.. 6. 6.. 6 60. 0 0. 79 7. 7 6. 99. 9 7... 0 9. 6. 0. 0 7.. 7 6 60. 0 06.. 7 6. 0 0. 00 7 7... 67.. 7.. 6. n: Stations 6 60. 0 0.. Note) The width of type (Matsushita lectric Works, Ltd.) and type G (ockwell utomation, Inc.) SI units are. mm greater. For details, please contact SMC. --

Circular Connector I67 compliant Tie-rod base Cassette base pplicable series Cassette base manifold 000/000 Tie-rod base manifold 000/000/000/000 Number of connectors: 6 pins --

For details about certified products conforming to international standards, visit us at www.smcworld.com. Circular Connector Tie-rod base S Cassette base --6 000 000 000 000 000 000 W S W 6C 0 Valve stations Type 6: 000 Symbol 0 09 0 Stations stations 9 stations stations nclosure I67 specifications Note ouble wiring specifications () Specified layout () (up to solenoids possible.) stations Type 6: 000 Symbol Stations Note 0 stations 0 0 U How to Order ouble wiring specifications () stations stations Specified layout () 0 stations (up to solenoids possible.) Note ) ouble wiring specifications: Single, double, position and position solenoid valves can be used at all of the manifold stations. Use of a single solenoid will result in an unused control signal. If this is not desired, order with a specified layout. Note ) Specified layout: Indicate wiring specifications on the manifold specification sheet. (Note that double, and position valves cannot be used where single solenoid wiring has been specified.), port location U side ( to 0 stations) side ( to 0 stations) oth sides ( to 0 stations) SU/XH block assembly specifications Nil S S Symbol 0 0 Stations stations stations 0 stations 0 stations Valve stations Note () ouble wiring specifications () Specified layout (Up to solenoids possible.) 0C Internal pilot Internal pilot/uilt-in silencer xternal pilot xternal pilot/uilt-in silencer 0 U U Note) When the built-in silencer type is used, keep the exhaust port from coming in direct contact with water or other liquids. Note ) ouble wiring specifications: Single, double, position and position solenoid valves can be used at all of the manifold stations. Use of a single solenoid will result in an unused control signal. If this is not desired, order with a specified layout. Note ) Specified layout: Indicate wiring specifications on the manifold specification sheet. (Note that double, and position valves cannot be used where single solenoid wiring has been specified.) Mounting Nil 0 0 irect mounting IN rail mounting (With IN rail) IN rail mounting (Without IN rail) For stations When a longer IN rail is desired than the specified stations. (Specify a longer rail than the For 0 stations standard length.) In the case of 0, only IN rail fittings are attached. IN rail length specified Nil Standard length For stations (Specify a longer rail than the standard length.) 0 Note) For 0 stations Note) ble to specify the length for stations up to stations for 000, which is available with station at the maximum., port size (Metric) Symbol Specifications, port pplicable series C fitting for ø. C fitting for ø fitting for ø C6 fitting for ø6 000 C fitting for ø C6 fitting for ø6 fitting for ø0 C fitting for ø 000 C6 fitting for ø6 C fitting for ø fitting for ø C0 fitting for ø0 000 C fitting for ø C0 fitting for ø0 fitting for ø C fitting for ø 0 c / 000 c / 0 c / 0F G / 0F G / G / M, ports mixed, port size (Inch) Symbol Specifications, port pplicable series N fitting for ø/" N fitting for ø/" 000 fitting for ø/6" N7 fitting for ø/" N fitting for ø/" N7 fitting for ø/" 000 fitting for ø/" N9 fitting for ø/6" N7 fitting for ø/" N9 fitting for ø/6" 000 fitting for ø/" N fitting for ø/" N9 fitting for ø/6" N fitting for ø/" fitting for ø/" 0N NT / NT / 000 0N NT / 0T NTF / NTF / 0T NTF / M, ports mixed In the case of mixed specifications (M), indicate separately on the manifold specification sheet. ort sizes of X, port for external pilot specification (, S) are ø(metric), ø/"(inch) for 000/000 and ø6 (metric) and ø/"(inch) for 000/000.

side Circular Connector How to Order Valve Manifold ssembly Ordering example (000) Manifold S-W6C-06-C6 ( set) ouble solenoid 00-FU ( sets) U side Stations Single solenoid 00-FU ( sets) S-W6C-06-C6 set (manifold part no.) 00-FU sets (Single solenoid part no.) 00-FU sets (ouble solenoid part no.) How to Order Solenoid Valves 00 F Note) Note) vailable with manifold block for station additions. efer to pages --9 and --9. 000 000 000 000 Manual override Nil: Non-locking push type : ush-turn locking slotted type Type of actuation position single solenoid position double solenoid position closed center position exhaust center position pressure center position dual port valve: N.C./N.C. position dual port valve: N.O./N.O. C position dual port valve: N.C./N.O. position dual port valves are applicable to 000 and 000 only. Nil ilot type Internal pilot xternal pilot xternal pilot specifications is not available for position dual port valves. ack pressure check valve Nil None K uilt-in uilt-in back pressure check valve type is applicable to series 000 only. ack pressure check valve is not available for position closed center and position pressure center. ated voltage 6 VC VC Light/Surge voltage suppressor U With light/surge voltage suppressor With surge voltage suppressor efer to recautions on page --9. --7

Manifold lectrical Wiring 0C/6C Circular Connector Type (6 pins) @6 @ Common Common! q!!6 w! @!7 e! @ @! r! @ @6!9 t!0 @ @0 y o i u Light/Surge voltage suppressor Light/Surge voltage suppressor Light/Surge voltage suppressor Light/Surge voltage suppressor @ @ @ @ r e w q SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. Station Station Station Station This circuit has double wiring specifications for up to stations. Since the usable number of solenoids differs depending on the manifold type, refer to the table below. In the case of single solenoids, connect to SOL.. Furthermore, when wiring is specified on a manifold specification sheet, connections are made without skipping any connectors, and connections are made without skipping any connectors, and signals for single and, for double are in order, etc. Stations are counted from side (connector side) as the st. Since solenoid valves do not have polarity, either the +COM or COM can be used. Usable No. of Solenoids Model Tie-rod base type 0 Cassette base type 6 000 to 000 000 000 Max. no. of solenoids --

9 7 6 Circular Connector imensions: 000 for Circular Connector U Stations Tie-rod base manifold: S-W0C- (S,, S) - C6, N7 C, N9 C0, N (-) When, port outlets are indicated on the U side or side, the, ports on the opposite side are plugged. xternal pilot port positions and silencer discharge port positions are the same as, port outlet positions. With xternal ilot Specifications..6. (itch) = 0.. 6. 7.6 6. fitting [(), /() port] pplicable tubing O..: ø ø/" U side IN rail holding screw (For IN rail mounting) (.) L L. fitting [(), () port] pplicable tubing O..: ø6, ø/" ø, ø/6" ø0, ø/" (.) (L) side 60. 76. fitting [X: xternal pilot port] pplicable tubing O..: ø6 ø/" X fitting [: ilot XH port] pplicable tubing O..: ø6 ø/" X......9 6 7 6.9 9.6 9.6 6 9 0 0 -ø. (For mounting) Manual override ress and turn for the ( locking type. ) () port side: Orange () port side: Green L (ail mounting hole pitch:.) L 0. Silencer (ir discharge port) (uilt-in silencer specifications). Notch (To align connector position) With option (Station n) (Station ) Light/Surge voltage suppressor (Cable assembly) Min. bending radius 0 mm 0.. / / 60.9. 9.7 0.7.7 6..7 (For IN rail mounting) (0) () (When circular connector is mounted) Individual SU spacer Individual XH spacer Interface regulator 000-M- Interface regulator 000-00- 9.9 7.9 MX. L imension L n L L L L L 7 6. 7.. 97 9 7. 6. 7... 7. 09.. 6 60. 0 9.. 79 7. 7 0. 7. 99. 9 7. 70.. 0 9. 9. 6 0. 0.. 6 60. 0... 7. 6. 0 9 7. 7.... 9.. 7.. 7 6. 6 60. 0. 7. 7. 0. 0. 00 7. 7. 9. 96... n: Stations 0 7. 6.. 66 --6

9 7 6 imensions: 000 for Circular Connector U Stations Tie-rod base manifold: S-W0C- (S,, S) - (itch) = 0, C, N9, 0, C0, N, C, (-) When, port outlets are indicated on the U side or side, the, ports on the opposite side are plugged. xternal pilot port positions and silencer discharge port positions are the same as, port outlet positions. 6. With xternal ilot Specifications 0. fitting [(), /() port] pplicable tubing O..: ø ø/" fitting [(), () port] pplicable tubing O..: ø, ø/6" ø0, ø/" ø U side -ø6. (For mounting) / L L (.) c / [(), () port] c /, / [(), () port] 7..7 (L). side 7.. / X fitting [X: xternal pilot port] pplicable tubing O..: ø6 ø/" Notch (To align connector position) fitting [: ilot XH port] pplicable tubing O..: ø6 ø/" X IN rail holding screw (For IN rail mounting) 6.7.. [For c /, /]. 7 9. 6. 7. 9.6 Manual override ress and turn for the ( locking type. ) () port side: Orange () port side: Green L (ail mounting hole pitch:.) L.7.9. Silencer (ir discharge port) (uilt-in silencer specifications) 6 7 6 9 0 0. With option /.6 / (Station n) (Station ) Light/Surge voltage suppressor 0.. Individual SU spacer 6. 07... 6..7 6. (For IN rail mounting) (0) (Cable assembly) Min. bending radius 0 mm (.) (When circular connector is mounted) Interface regulator 000-M- 0.9 7.9 Individual XH spacer Interface regulator 000-00- MX.0 L imension L n L L L L L 9 7. 6. 7. 09 0. 00 6.. 0.. 7 60. 0. 6. 7.. 0 7 0. 00. 9. 06.. 9 60. 0 0. 77 0. 7.. 0 0. 00 7. 6. 0. 6. 9 60. 0 6. 7 7. 7 0. 7. 97 9 7. 7.. 6. 9. 7 7... 69 7 6. 6. 9 9 9 7. 70.. 7 n: Stations 0 6 6. 9. --6

-sub Connector Tie-rod base Cassette base pplicable series Cassette base manifold 000/000 Tie-rod base manifold 000/000/000/000 Number of connectors: pins MIL-C-0 Conforming to JIS-X-0 --6

For details about certified products conforming to international standards, visit us at www.smcworld.com. Tie-rod base Cassette base Valve stations 000 Symbol 0 09 0 000 Symbol 0 0 Stations stations 9 stations stations stations Stations stations stations 0 stations 0 stations --66 000 000 -sub Connector 000 000 000 000 S 0F How to Order Valve stations Symbol 0 0 Stations stations stations 0 stations 0 stations S 6F 0 U Note () ouble wiring specifications Specified layout () (Up to solenoids possible.) Note () ouble wiring specifications () Specified layout (Up to solenoids possible.) Connector entry direction Upward Lateral ilot type Note () ouble wiring specifications () Specified layout (Up to solenoids possible.) Note ) ouble wiring specifications: Single, double, position and position solenoid valves can be used at all of the manifold stations. Use of a single solenoid will result in an unused control signal in an unused control signal. If this is not desired, order with a specified layout. Note ) Specified layout: Indicate wiring specifications on the manifold specification sheet. (Note that double, and position valves cannot be used where single solenoid wiring has been specified.), port location U Nil S S, port size (metric) Symbol, port C fitting for ø. C fitting for ø C6 fitting for ø6 C fitting for ø C6 fitting for ø6 C fitting for ø C6 fitting for ø6 C fitting for ø C0 fitting for ø0 C fitting for ø C0 fitting for ø0 C fitting for ø 0 c / 0 c / 0F G / 0F G / M 0 U U side ( to 0 stations) side ( to 0 stations) oth sides ( to 0 stations) Internal pilot Internal pilot/uilt-in silencer xternal pilot xternal pilot/uilt-in silencer, port pplicable series fitting for ø fitting for ø0 fitting for ø fitting for ø c / G /, ports mixed 000 000 000 000 Note ) ouble wiring specifications: Single, double, position and position solenoid valves can be used at all of the manifold stations. Use of a single solenoid will result in an unused control signal in an unused control signal. If this is not desired, order with a specified layout. Note ) Specified layout: Indicate wiring specifications on the manifold specification sheet. (Note that double, and position valves cannot be used where single solenoid wiring has been specified.) Mounting IN rail length specified Nil Standard length For stations (Specify a longer rail than the standard 0 Note) For 0 stations length.) Note) ble to specify the length for stations up to stations for 000, which is available with stations at the maximum. Nil 0 0 irect mounting IN rail mounting (With IN rail) IN rail mounting (Without IN rail) For stations For 0 stations, port size (inch) Symbol, port N fitting for ø/" N fitting for ø/" N7 fitting for ø/" N fitting for ø/" N7 fitting for ø/" N9 fitting for ø/6" N7 fitting for ø/" N9 fitting for ø/6" N fitting for ø/" N9 fitting for ø/6" N fitting for ø/" 0N NT / 0N NT / 0T NTF / 0T NTF / M, port pplicable series fitting for ø/6" fitting for ø/" fitting for ø/" fitting for ø/" NT / NTF / When a longer IN rail is desired than the specified stations. (Specify a longer rail than the standard In case of 0, only IN rail fittings are attached., ports mixed In the case of mixed specifications (M), indicate separately on the manifold specification sheet. ort sizes of X, port for external pilot specifications (, S) are ø (metric), ø/" (inch) for 000/000 and ø6 (metric) and ø/" (inch) for 000/000. 000 000 000 000

side -sub Connector How to Order Valve Manifold ssembly Ordering example (000) Manifold S-6F-06-C6 ( set) ouble solenoid 00-FU ( sets) Single solenoid 00-FU ( sets) U side S-6F-06-C6 set (manifold part no.) 00-FU sets (Single solenoid part no.) 00-FU sets (ouble solenoid part no.) Stations How to Order Solenoid Valves 00 F Note) Note) vailable with manifold block for station additions. efer to pages --9 and --9. 000 000 000 000 Manual override Nil: Non-locking push type : ush-turn locking slotted type Type of actuation position single solenoid position double solenoid position closed center position exhaust center position pressure center position dual port valve: N.C./N.C. position dual port valve: N.O./N.O. C position dual port valve: N.C./N.O. position dual port valves are applicable to 000 and 000 only. ilot type Nil Internal pilot xternal pilot xternal pilot specifications is not available for position dual port valves. ated voltage 6 VC VC Light/Surge voltage suppressor U With light/surge voltage suppressor With surge voltage suppressor ack pressure check valve Nil None K uilt-in uilt-in back pressure check valve type is applicable to series 000 only. ack pressure check valve is not available for position closed center and position pressure center. efer to recautions on page --9. --67

Manifold lectrical Wiring 0F/6F -sub Connector Type ( pins) Light/Surge voltage suppressor Light/Surge voltage suppressor Common Common SOL. Station SOL. Light/Surge voltage suppressor SOL. SOL. Station Light/Surge voltage suppressor SOL. Station SOL. This circuit has double wiring specifications for up to stations. Since the usable number of solenoids differs depending on the manifold type, refer to the table below. In the case of single solenoids, connect to SOL.. Furthermore, when wiring is specified on the manifold specification sheet, connections are made without skipping any connectors, and signals for single and, for double are in order, etc. Stations are counted from side (connector side) as the st. Since solenoid valves do not have polarity, either the +COM or COM can be used. Usable No. of Solenoids Model Tie-rod base type 0 Cassette base type 6 000 to 000 000 000 Max. no. of solenoids --6

-sub Connector imensions: 000 for -sub Connector U Stations Tie-rod base manifold: S-0F (S,, S) - - C6, N7 C, N9 C0, N (-) When, port outlets are indicated on the U side or side, the, ports on the opposite side are plugged. xternal pilot port positions and silencer discharge port positions are the same as, port outlet positions. With xternal ilot Specifications. (itch) = 0....6. 6. fitting [(), /() port] pplicable tubing O..: ø ø/" U side IN rail holding screw (For IN rail mounting) (.) L L (Lateral connector entry) fitting [(), () port] pplicable tubing O..: ø6,ø/" ø, ø/6" ø0, ø/" (.). (L) 7.6 side 60. 76. quivalent to applicable -sub connector fitting [X: xternal pilot port] pplicable tubing O..: ø6 ø/" X { } JIS-X-0 MIL-C-0 fitting [: ilot XH port] pplicable tubing O..: ø6 ø/" X 7.9... 6.9 9.6...9 -ø. (For mounting) Light/Surge voltage suppressor Manual override ress and turn for the ( locking type. ) () port side: Orange () port side: Green L (ail mounting hole pitch:.) L (Station n) (Station ) 0. -M.6 --0 UNC [(), () with inch size ports] Connector case elease lever (oth sides) Silencer (ir discharge port) (uilt-in silencer specifications) With option 0.. / / 60.9 (For IN rail mounting). 9.7 0.7 (6).7 6. (.9) 66. Individual SU spacer.7 (0) MX. 9.9 7.9 Individual XH spacer Interface regulator 000-M- Interface regulator 000-00- L imension L n L L L L L 60. 0. 97 7 6... 7. 9 7. 6 0.... 6. 0 9 79 7 60. 0. 99.. 7. 0 9 9 7. 6. 9. 0. 0. 6. 6 7. 06.. 60. 0 7 0 0. 7 7.. 9 7. 6.. 0. 6. 6 7. 09. 7 60. 0 9.. 0.. 7 0 9 0. 00 70.. n: Stations 0. 9 9 66 --7

Flat ibbon Cable Connector Tie-rod base Cassette base pplicable series Cassette base manifold 000/000 Tie-rod base manifold 000/000/000/000 Number of connectors: 6, 0, 0 pins With strain relief Conforming to MIL-C-0 --7

For details about certified products conforming to international standards, visit us at www.smcworld.com. Flat ibbon Cable Connector Connector type G H Tie-rod base 000 000 000 000 Cassette base Flat ribbon cable connector: 6 pins Flat ribbon cable connector: 0 pins Flat ribbon cable connector: 0 pins S 0 000 000 Valve stations 000 : Flat ribbon cable 6 pins 0 09 0 stations 9 stations stations How to Order S 6 0 U () ouble wiring specifications Specified layout () (Up to solenoids possible.) Connector entry direction Upward Lateral, port location U Nil S S 0 U U side ( to 0 stations) side ( to 0 stations) oth sides ( to 0 stations) ilot type H: Flat ribbon cable 0 pins 0 0 0 stations stations stations ouble wiring () specifications Specified layout () (Up to solenoids possible.) stations 0 G: Flat ribbon cable 0 pins 0 stations () ouble wiring specifications 09 0 9 stations stations stations () Specified layout (Up to solenoids possible.) stations Valve stations : Flat ribbon cable 6 pins H: Flat ribbon cable 0 pins 0 0 stations stations stations () ouble wiring specifications () Specified layout 0 0 0 stations stations stations () ouble wiring specifications () Specified layout 0 (Ip to solenoids possible.) (Up to solenoids possible.) 0 stations 0 stations G: Flat ribbon cable 0 pins 0 stations () ouble wiring 09 9 stations specifications 0 stations () Specified layout stations (Up to solenoids possible.) Internal pilot Internal pilot/uilt-in silencer xternal pilot xternal pilot/uilt-in silencer 000 IN rail length specified Nil Standard length For stations (Specify a longer rail than the 0 Note) For 0 stations standard length.) Note) ble to specify the length for stations up to stations for 000, which is available with stations at the maximum. : Flat ribbon cable 6 pins H: Flat ribbon cable 0 pins 0 stations () 0 stations () ouble wiring ouble wiring 0 stations stations specifications Specified layout () 0 0 stations stations specifications Specified layout () 0 (Up to solenoids possible.) (Up to solenoids possible.) 0 stations 0 stations G: Flat ribbon cable 0 pins 0 stations () ouble wiring 09 9 stations specifications 0 stations () Specified layout stations (Up to solenoids possible.) Mounting Nil irect mounting IN rail mounting (With IN rail) 0 IN rail mounting (Without IN rail) For When a longer stations IN rail is desired than the specified stations. (Specify For 0 0 a longer rail than stations the standard In case of 0, only IN rail fittings are attached. --76 Note ) ouble wiring specifications: Single, double and position solenoid valves can be used on all manifold stations. Use of a single solenoid will result in an unused control signal. If this is not desired, order with a specified layout. Note ) Specified layout: Indicate wiring specifications on a manifold specification sheet.

Flat ibbon Cable Connector How to Order Valve Manifold ssembly Ordering example (000) Manifold S-6-06-C6 ( set) ouble solenoid 00-FU ( sets) Single solenoid 00-FU ( sets) U side Stations Type of actuation 00 F 000 000 000 000 side position single solenoid position double solenoid position closed center position exhaust center position pressure center position dual port valve: N.C./N.C. position dual port valve: N.O./N.O. position dual port valve: N.C./N.O. C position dual port valves are applicable to 000 and 000 only. ilot type Nil Internal pilot xternal pilot xternal pilot specifications is not available for position dual port valves. How to Order Solenoid Valves S-6-06-C6 set (manifold part no.) 00-FU sets (Single solenoid part no.) 00-FU sets (ouble solenoid part no.) ated voltage 6 VC VC ack pressure check valve Note) vailable with manifold block for station additions. efer to pages --9 and --9. Manual override Nil: Non-locking push type : ush-turn locking slotted type Light/Surge voltage suppressor U Note) With light/surge voltage suppressor With surge voltage suppressor Nil None K uilt-in uilt-in back pressure check valve type is applicable to series 000 only. ack pressure check valve is not available for position closed center and position pressure center. efer to recautions on page --9., port size (Metric), port size (Inch) Symbol C, port fitting for ø., port pplicable series Symbol N, port C fitting for ø 000 N fitting for ø C6 fitting for ø6 N7 C fitting for ø N C6 fitting for ø6 000 N7 fitting for ø0 C fitting for ø N9 C6 fitting for ø6 N7 C fitting for ø 000 N9 fitting for ø C0 fitting for ø0 N C fitting for ø N9 C0 fitting for ø0 N fitting for ø C fitting for ø 0N 0 c / 000 0N c / 0 c / 0T 0F G / 0T NTF / G / 0F G / M M, ports mixed fitting for ø/" fitting for ø/" fitting for ø/" fitting for ø/" fitting for ø/" fitting for ø/6" fitting for ø/" fitting for ø/6" fitting for ø/" fitting for ø/6" fitting for ø/" NT / NT / NTF /, port pplicable series fitting for ø/6" fitting for ø/" fitting for ø/" fitting for ø/" NT / NTF /, ports mixed 000 000 000 000 In the case of mixed specifications (M), indicate separately on the manifold specification sheet. ort sizes of X, port for external pilot specification (, S) are ø (metric), ø/" (inch) for 000/000 and ø6(metric) and ø/" (inch) for 000/000. --77

Manifold lectrical Wiring 0/6 Flat ibbon Cable Type (6 pins) 0G/6G Flat ibbon Cable Type (0 pins) Light/Surge voltage suppressor Light/Surge voltage suppressor Light/Surge voltage suppressor Light/Surge voltage suppressor 6 Common Common SOL. SOL. SOL. SOL. Station Station SOL. Station SOL. SOL. Station SOL. Triangle mark Light/Surge voltage suppressor Light/Surge voltage suppressor Light/Surge voltage suppressor Light/Surge voltage suppressor 0 9 7 6 Common Common SOL. SOL. SOL. SOL. SOL. SOL. Station 9 Station Station SOL. Station SOL. Triangle mark This circuit has double wiring specifications for up to stations. Since the usable number of solenoids differs depending on the manifold type, refer to the table below. In the case of single solenoids, connect to SOL.. Furthermore, when wiring is specified on a manifold specification sheet, connections are made without skipping any connectors, and connections are made without skipping any connectors, and signals for single and, for double are in order, etc. Stations are counted from side (connector side) as the st one. Since terminal numbers are not indicated on the flat cable, use the triangle mark as a reference for wiring. Since solenoid valves do not have polarity, either the +COM or COM can be used. Usable No. of Solenoids Model Max. no. of solenoids 000 Tie-rod base type 0 to 000 Cassette base type 6 000 000 This circuit has double wiring specifications for up to 9 stations. Since the usable number of solenoids differs depending on the manifold type, refer to the table below. In the case of single solenoids, connect to SOL.. Furthermore, when wiring is specified on a manifold specification sheet, connections are made without skipping any connectors, and connections are made without skipping any connectors, and signals for single and, for double are in order, etc. Stations are counted from side (connector side) as the st one. Since terminal numbers are not indicated on the flat cable, use the triangle mark as a reference for wiring. Since solenoid valves do not have polarity, either the +COM or COM can be used. Usable No. of Solenoids Model Max. no. of solenoids 000 Tie-rod base type 0 to 000 000 Cassette base type 6 000 0H/6H Flat ibbon Cable Type (0 pins) 0 9 Common Common Light/Surge voltage suppressor 7 SOL. SOL. Station Light/Surge voltage suppressor Light/Surge voltage suppressor Light/Surge voltage suppressor SOL. SOL. Station SOL. Station SOL. Triangle mark This circuit has double wiring specifications for up to stations. Since the usable number of solenoids differs depending on the manifold type, refer to the table below. In the case of single solenoids, connect to SOL.. Furthermore, when wiring is specified on a manifold specification sheet, connections are made without skipping any connectors, connections are made without skipping any connectors, and signals for single and, for double are in order, etc. Stations are counted from side (connector side) as the st one. Since terminal numbers are not indicated on the flat cable, use the triangle mark as a reference for wiring. Since solenoid valves do not have polarity, either the +COM or COM can be used. Usable No. of Solenoids Model Max. no. of solenoids 000 Tie-rod base type 0 to 000 000 Cassette base type 6 000 --7

Flat ibbon Cable Connector imensions: 000 for Flat ibbon Cable Tie-rod manifold: S-0 G - Stations (S,, S) - C, N9 (-) H U C6, N7 C0, N When, port outlets are indicated on the U side or side, the, ports on the opposite side are plugged. xternal pilot port positions and silencer discharge port positions are the same as, port outlet positions. With xternal ilot Specifications. (itch) = 0... 6...6 7.6 60. 76. X X fitting [(), /() port] pplicable tubing O..: ø ø/" fitting [(), () port] pplicable tubing O..: ø6,ø/" ø, ø/6" ø0, ø/" fitting fitting [X: xternal pilot port] [: ilot XH port] pplicable tubing O..: ø6 pplicable tubing O..: ø6 ø/" ø/" U side IN rail holding screw (For IN rail mounting) (.) L L (.). (L) side pplicable connector: 6 pins MIL type (Conforming to MIL-C-0)... 6.9 9.6. 9.9..9 Triangle mark position -ø. (For mounting) Manual override ress and turn for the ( locking type. ) () port side: Orange () port side: Green L (ail mounting hole pitch:.) L 0. (Lateral connector entry) Connector case elease lever (oth sides) Silencer (ir discharge port) (uilt-in silencer specifications) (Station n) (Station ) Light/Surge voltage suppressor (.9) pplicable connector: 0 pins MIL type (Conforming to MIL-C-0) pplicable connector: 0 pins MIL type (Conforming to MIL-C-0).7 6..7 (For IN rail mounting) (0) (.9) 79.7 0G (0 pins) Triangle mark position 0H (0 pins) Triangle mark position efer to page --7 (compliant for -sub connector) for dimensions with interface regulator and individual SU/XH spacer. L imension L n L L L L L 60. 0. 97 7 6... 7. 9 7. 6... 6. 0 9 79 7 60. 0.. 99.. 7. 0 9 9 7. 6. 9. 0. 0. 6 6 7. 06.. 60. 0 7 0 0. 7 7... 9 7. 6... 0. 6. 6 7. 09 7 60. 0 9. 9 0.. 7 0 9 0. 00 70... n: Stations 0. 9 9. 66 --

Type 0: Tie-rod ase Manifold xploded View U side a! Caution Mounting Screw Tightening Torques w!0 q M: 0. N m M: 0.6 N m M:. N m M:.9 N m Unless otherwise indicated, tighten mounting screws to the torques shown above.!!!! e!6!7 Note) Included only with the IN rail mounting style (with IN rail). Included only with the IN rail mounting style. 000, 000 IN rail holding screw tightening torque:. N m side!7 Note) Included only with the IN rail mounting style. 000, 000 IN rail holding screw tightening torque:. N m X0 (Type 0S W) e SU/XH block assembly Circular connector (Type 0C) t y u -sub connector (Type 0F) i Note) t, y, u and i are not included in the SU/XH block assembly. Included only with the IN rail mounting style. (Tightening torque of IN rail holding screw: 0. N m) X00 (Type 0S W) r X0 (Type 0S ) For flat ribbon cable connector (Type 0 ) o r is not included in the SU/XH block assembly. o is not included in the SU/XH block assembly. Note) i and!7 are for 000. Mounting orientation onto IN rail gets reversed. --90

q Manifold lock ssembly art No. 000 000 000 000 Wiring specifications Single ouble Single ouble Single ouble Single ouble Manifold block ass y part no. 000-0-- 000-0-- 000-0-- 000-0-- 000-0-- 000-0-- 000-0-- 000-0-- w SU/XH end block assembly e SU/XH block assembly 000 000 000 000 Note C: With fitting for ø. N: fitting for ø/" C: With fitting for ø N: fitting for ø/" C6: With fitting for ø6 N7: fitting for ø/" (Tie-rod for station additions! and gaskets!0,!, and! are included.) C: With fitting for ø N: fitting for ø/" C6: With fitting for ø6 N7: fitting for ø/" C: With fitting for ø N9: fitting for ø/6" (Tie-rod for station additions! and gaskets!0,!, and! are included.) C6: With fitting for ø6 N7: fitting for ø/" C: With fitting for ø N9: fitting for ø/6" C0: With fitting for ø0 N: fitting for ø/" (Tie-rod for station additions! and gaskets!0,!, and! are included.) C: With fitting for ø N9: fitting for ø/6" C0: With fitting for ø0 N: fitting for ø/" C: With fitting for ø 0: c / 0N: NT / 0: c / 0N: NT / 0F: G/ 0T: NTF/ 0F: G/ 0T: NTF / (Tie-rod for station additions! and gaskets!0,!, and! are included.) 000 U 000 0 6 Connector entry direction (-sub, flat types only) Upward Lateral SU/XH block assembly specifications For X00 (SI unit) For X0 (SI unit) For circular connector -sub connector For flat ribbon cable connector (6 pins) For Flat ribbon cable connector (0 pins) For Flat ribbon cable connector (0 pins) For X0 (dedicated output serial) Since X00 and X0 type SI units are not included, order them separately. Nil S S ilot type Internal pilot Internal pilot/uilt-in silencer xternal pilot xternal pilot/uilt-in silencer Mounting Nil 0 irect mounting IN rail mounting, port size C fitting for ø N9 fitting for ø/6" C0 fitting for ø0 N fitting for ø/" C fitting for ø N fitting for ø/" 0 c / 0F G / 0N NT / 0T NTF / 00 lug 000 000 000 000 000 ll series 00 (lug) is not available for S, and S types. No. r t y u i o!0!!!!!!6!7 escription X00 SI unit X0 SI unit X0 input block X0 end plate assembly X0 clamp assembly X0 SI unit Gasket Connector gasket Manifold block gasket Tie-rod Tie-rod for station addition ound head combination screw (Valve mounting screw) IN rail Clamp assembly 000 000-7- 000-6- 000-- 000--- 000--- 000-- (M x ) 000--- 000-69 art no. 000 000 efer to page --6. X0-SN X0-I X0-I X0-I X0-000-7 efer to page --. 000-7-6 000-6- 000-- VZ000--- 000-- 000-- (M x 0) 000--- 000-69 7000-7- 000-6- 000-6- 000--- 000-- 000-- (M x ) VZ000--- 000-69 000 9000-- 000-6- 000-6- VZ000--- 000-- 000-- (M x 0) VZ000--- 000-69 Note) Two pieces of! and! (tie-rod) are required for 000, and three pieces are required for 000, 000 and 000. Two pieces of! (valve mounting screw) are required for 000, 000 and 000, and three pieces are required for 000. Note For evicenet M, inputs M, inputs M, inputs ( pins) With mounting screws (M x 0, pcs.) : Manifold stations efer to IN rail dimension tables on page --97. --9

Type 0: Tie-rod ase Manifold How to increase manifold bases (Type 0) () Loosen the U side screws a, and remove the SU/XH end block assembly w. () Screw in the tie-rods for station addition. (Screw them in until there is no gap between the tie-rods.) Tie-rod for station addition () Connect the manifold assembly q and supply/exhaust end block assembly w to be added, and tighten the screws a. Caution Tightening torques a 000, 000 0.6 N m 000. N m 000.9 N m Note) When eliminating manifold stations, the appropriate tie-rods! for the desired change should be ordered separately. (When equipped with a IN rail, be sure to tighten the IN rail holding screws after tightening the tension bolts.) Caution Fitting ssembly eplacement y replacing manifold fitting assemblies, it is possible to change the size of the, ports and, ports. To replace them, remove the clip with a flat head screwdriver, etc., and pull out the fitting assembly. Mount the new fitting assembly by inserting it and then replacing the clip to its fully inserted position. Fitting ssembly art No., ort, ort ort size fitting for ø. fitting for ø fitting for ø6 fitting for ø fitting for ø0 fitting for ø fitting for ø/" fitting for ø/" fitting for ø/" fitting for ø/6" fitting for ø/" / threaded type port block assembly / threaded type port block assembly fitting for ø fitting for ø0 fitting for ø fitting for ø/6" fitting for ø/" / threaded type port block assembly 000 VVQ000-0-C VVQ000-0-C VVQ000-0-C6 VVQ000-0-N VVQ000-0-N VVQ000-0-N7 VVQ000--C VVQ000--N9 000 VVQ000--C VVQ000--C6 VVQ000--C VVQ000--N VVQ000--N7 VVQ000--N9 VVQ000--C0 VVQ000--N 000 VVQ000--C6 VVQ000--C VVQ000--C0 VVQ000--N7 VVQ000--N9 VVQ000--N VVQ000-0-C VVQ000-0-N 000 VVQ000-0-C VVQ000-0-C0 VVQ000-0-C VVQ000-0-N9 VVQ000-0-N 9000--0 9000--0 VVQ000-0-C VVQ000-0-N 9000--0 --9

/, / thread type port block assembly For, port 9000 0 0 For, port 9000 0 Thread type Nil F N T c G NT NTF Note ) e careful to avoid damage or contamination of O-rings, as this can cause air leakage. Note ) When removing a fitting assembly from a valve, after removing the clip, attach tubing or a plug (KQ- ) to the fitting, and pull it out while holding the tubing (or plug). If it is pulled out while holding the release button of the fitting assembly (resin part), the release button may be damaged. However, 0 and 0 port block assemblies should be pulled out as they are. Note ) e sure to shut off the power and air supplies before disassembly. Furthermore, since air may remain inside the actuator, piping and manifold, confirm that the air is completely exhausted before performing any work. Clip O-ring Fitting assembly How to order tie-rod type 0 solenoid valves with manifold block [ 000 to 000] Type with manifold block is used when adding stations, etc. 00 F 000 000 000 000 Type of actuation position single solenoid position double solenoid position closed center position exhaust center position pressure center position dual port valve: N.C./N.C. position dual port valve: N.O./N.O. C position dual port valve: N.C./N.O. position dual port valves are applicable to 000 and 000 only. ilot type Nil Internal pilot xternal pilot xternal pilot specifications is not available for position dual port valves. ack pressure check valve Nil None K uilt-in uilt-in back pressure check valve type is applicable to series 000 only. ack pressure check valve is not available for position closed center and position pressure center. efer to recautions on page --9. ated voltage 6 VC VC Manual override Nil: Non-locking push type Light/Surge voltage suppressor U Note that serial wiring (X00, X0 and X0) are only available with VC. Manifold wiring specifications Nil S ouble wiring Single wiring Manifold block type For Tie-rod base type 0 with T manifold block Note) Tie-rod type 0 includes tie-rods for station additions. With light/surge voltage suppressor With surge voltage suppressor, port size efer to, port size table on pages --0, 6,, and 76. : ush-turn locking slotted type xample (000) 00-FU-T-C6 --9

Manifold Option (Common for Type 6 and 0) elay output module y adding a relay output module to a series manifold, devices up to 0 VC, (large type solenoid valves, etc.) can be controlled together with valves. How to Order 000 60 elay output module Light window 000 000 000 000 elay Output Module Specifications Item No. of output points Output type No. of output point output outputs ated voltage VC 6 VC output [connector with lead wire (M)] pins connector (M) plug.. Output.. Output Contact type ( a contact) Note that serial wiring manifolds (X00, X0 and X0) are available with VC only. elay output module side pin arrangement Specifications pins connector (M) plug. Output. Output. Output. Output outputs [connector with lead wire (M)] Contact type ( a contact) elay output module side pin arrangement Load voltage Load current Indicator light nclosure Current consumption olarity weight (g) 0 VC Orange 0 VC 0 VC 0 VC 0. side: Orange side: Green ased on I67 (IC9) 0 m or less Non-polar Y type connector Used to branch a two output relay output module to two separate systems. How to Order X00 CY00 S elay output module and Y type connector wiring example Solenoid Y type connector elay output module ( outputs) Output Solenoid Output --9

Manifold Option lanking plate assembly Used in situations where valves will be added in the future. 000 000 000 000 lanking plate assembly part no. 000-67- 000-67- 000-67- 000-67- SU/XH block disk [SU block disk] Caution Mounting screw tightening torques M: 0. N m M: 0.6 N m M:. N m y placing a SU block disk in a manifold valve s pressure supply passage, two different high and low pressures can be supplied to one manifold. [XH block disk] y installing an XH block disk in a manifold valve s exhaust passage, the valve s exhaust can be separated so that it will not affect other valves. It can also be used on a manifold with mixed positive pressure and vacuum. (Two pieces are required to block XH on both sides. However, 000 and 000 type 0 manifolds require only one piece.) Label for block disk These labels are attached to manifolds in which SU and XH block disks have been installed, in order to identify the installed locations. (Three sheets each included.) 000 7 Label for SU block disk Silencer with fitting This silencer can be quickly mounted on the manifold s (exhaust) port. 000 (For ø) 000 (For ø0) 000 000 (For ø) Label for XH block disk Model N0-KM N00-KM0 N00-KM0 N00-KM ffective area mm 6 m 0 mm mm Label for SU/XH block disk When a block disk is concurrently ordered by specifying on the manifold specification sheet, etc., a label will be stuck on the position where block disk is mounted. SMC C ø6 ø ø ø 6. 70 70 C 0. 97 9 lug (White) These are inserted in unused cylinder ports and, ports. Cassette base type 6 Tie-rod base type 0 d 000 000 000 000 Manifold Model 0 6 0 6 0 0 SU block disk 000-9- 000-77- 000-9- 000-9- 000-9- 9000-7- XH block disk 000-9- 000-77- 000-9- 000-9- 000-9- 9000-7- pplicable fitting size d ø ø6 ø ø0 ø ø/" ø/" ø/" ø/6" ø/" L Model KQ-0 KQ-06 KQ-0 KQ-0 KQ- KQ-0 KQ-0 KQ-07 KQ-09 KQ- 6 0. 6 6 0. L 9.. 9 ø6 ø ø0 ø ø ø ø6 ø. ø0 ø. --9

Manifold Option Circular connector/cable assembly (6 pins) XT00 MC6 Lead Wire Length art no. XT00-MC6-0 XT00-MC6-00 XT00-MC6-00 L dimension. m m m -sub connector/cable assembly ( pins) XT00 S Lead Wire Length art no. XT00-S-0 XT00-S-00 XT00-S-00 L dimension. m m m (60) L When a commercially available connector is required, use a pin female connector conforming to MIL-C0. 6 L 7.0 0 lug terminal no. (arrangement as seen from lead wire side)! q!!6 w! @!7 e! @ @! r! @ @6!9 t!0 @ @0 y o i u Circular Connector Cable ssembly Terminal No. Terminal no. Lead wire color q lack w rown e ed r Orange t Yellow y ink u lue i urple o Gray!0 White! White! Yellow! Orange! Yellow! ink!6 lue!7 urple! Gray!9 Orange @0 ed @ rown @ ink @ Gray @ lack @ White ot marking None None None None None None None White lack lack ed ed ed lack lack White None None lack White White ed ed White None Note) Terminal no.@6 is connected to @ inside the connector. Terminal no. Socket side -M.6 x 0. -sub Connector Cable ssembly Terminal No. Terminal no. Lead wire color q lack w rown e ed r Orange t Yellow y ink u lue i urple o Gray!0 White! White! Yellow! Orange! Yellow! ink!6 lue!7 urple! Gray!9 Orange @0 ed @ rown @ ink @ Gray @ lack @ White ot marking None None None None None None None White lack lack ed ed ed lack lack White None None lack White White ed ed White None Circular Connector, -sub Connector Cable ssembly lectric Characteristics Item Characteristics Conductor resistance W/km, 0 C 6 or less Withstand voltage VC, min. 000 Insulation resistance, M/km, 0 C or less Note) The minimum inside bending radius for each cable is 0 mm. " ø0 Multi-core vinyl cable 0. mm x C --96

Manifold Option Flat ribbon cable/cable assembly XT00 FC 000/000 and X00 input unit IN rail dimensions and weights VZ000 Cable length L. m m m Connector width (W) 0 pins XT00-FC0- XT00-FC0- XT00-FC0-7. 0 pins XT00-FC0- XT00-FC0- XT00-FC0-0 6 pins XT00-FC6- XT00-FC6- XT00-FC6-7. For other commercial connectors, use a type with strain relief conforming to MIL-C-0. W 6 6 ed s for, enter the number from the IN rail dimensions table. L (7.). No. L dimension Weight (g) 0 9 7.6 No. 0 L dimension Weight (g) 0. 0. 9.9.. ail mounting hole pitch...6.. 60. 6.9 6.6 7 9. 60..9.. () () 6 7. 6 9.6 7.. 7 0..9 9.6. 9 0. 7.9 9. 60. Terminal no. (.6) L No. L dimension 0 60. 7. 9 0. 6 7. 9 60. Connector manufacturers example Hirose lectric Co., Ltd. Sumitomo M Limited Fujitsu Limited Japan viation lectronics Industry, Ltd. J.S.T. Mfg. Co., Ltd. Weight (g) No. L dimension Weight (g) No. L dimension Weight (g) 6. 0 7. 0 9 07.6 6.9. 7. 60. 09.9 67. 9 9.6 6. 69. 0. 9.9 6.. 7.6 9. 6 6.6 7.9. 96. 660..9 76. 6 9.6 6 67. 7. 7 60. 00.9 7 6.. 0.6 7 0. 69.6.9 9. 0. 9 70. 7.9 No. 0 7 6 7 9 L dimension 7 7. 7 760. 7 7. 79 0.. Weight (g) 0...6 6.9 9...6.9. 0. No. 60 6 6 6 6 6 66 67 6 69 L dimension 60. 7. 9 90. 9 9. 9 960. Weight (g).6.9 7. 9. 6.6 6.9 66. 6. 70.6 7.9 No. 70 7 L dimension 97 9. Weight (g) 7. 77. 000 and 000 IN rail dimensions and weights VZ000 s for, enter the number from the IN rail dimensions table. L. () () ail mounting hole pitch. (0) No. 0 6 7 9 0 6 7 9 0 L dimension 9 0.. 60. 7. 9 0.. 60. 7. 9 0.. Weight (g)... 7. 0.6. 6.9 0.. 6. 9.6 6.7 6.9 69. 7. 7. 7.6.7.9 No. 6 7 9 0 6 7 9 0 L dimension 60. 7. 9 0.. 60. 7. 9 0.. 60. 7. 9 60. Weight (g) 9. 9. 97. 00.7 0.9 07 0.. 6. 9.7. 6 9....6.... No. 6 7 9 0 6 7 9 60 6 6 L dimension 6 6. 6 660. 67 6. 69 70. 7 7. 7 760. 77 7. 79 0.. 60. 7 Weight (g) 7.6 60. 6.9 67. 70. 7. 76.6 79..9 6. 9. 9. 9.6 9.7 0.9 0. 0... 7.7 0.9 No. 6 6 6 66 67 6 69 70 7 L dimension. 9 90. 9 9. 9 960. 97 9. Weight (g) 7. 0.. 6.7 9. 6. 9. --97

Manifold Option Interface regulator How to order interface regulator 000 000/000/000 0 00 0 000 00 pplicable valve 0 For single, double For position egulating port 0 06 M Option port port ( controlled type, port regulation) port ( controlled type, port regulation) With pressure gauge [For odd number station] With pressure gauge [For even number station] Without pressure gauge Note) In the case of 000 with a pressure gauge when mounting on the manifold, use caution that the part numbers are different between the odd no. stations and the even no. stations to avoid pressure gauges from interfering from each others. Note) Use caution that the part numbers will be differed depending on the one for single/double and position due to the different length of solenoid valves. lso, when at least the one for position is included in the same manifold, use all the ones for position. 000 000 000 00 M Option egulating port port port ( controlled type, port regulation) port ( controlled type, port regulation) With pressure gauge Without pressure gauge 000- -0 000- -06 000- -M 000- -00 000- -M 000- -00 (For mounting odd number stations) (For mounting even number stations) 000- -M 000- -00 000- -M ccessory JIS Symbol () () () () () () () () () () () () 000 000 000 000 Caution ound head combination screw 000--9 (M x 9.) 000--7 (M x ) 000-- (M x 7) 000-- (M x 69.) Gasket 000-7- 000-7-6 7000-7- 9000-- () port regulation () port regulation ( controlled type, port regulation) () port regulation ( controlled type, port regulation) Mounting Screw Tightening Torques M: 0. N m M: 0.6 N m M:. N m --9

Manifold Option Individual SU spacer assembly Individual XH spacer assembly SU port XH port How to order individual SU/XH spacer assembly 000 000/000/000 000 C6 000 ccessory 000 000 000 000 ound head combination screw 000--9 (M x 9.) 000--6 (M x 6) 000-- (M x ) 000-- (M x 60) ort size C C C6 N N N7 Spacer type Individual SU spacer 9 Individual XH spacer Gasket 000-7- 000-- 7000-- 9000-- fitting for ø. fitting for ø fitting for ø6 fitting for ø/" fitting for ø/" fitting for ø/" 000 000 000 000 000 000 Thread type Note) Nil F N T ort size / / c G NT NTF Note) 000/000/000 port size --99

000/000/000/000 Single Valve/Sub-plate Type I67 Compliant Type of actuation position single solenoid () position double solenoid () () () ()() () () ()() position closed center () () () ()() position exhaust center () () () ()() position pressure center () () ilot type Internal pilot xternal pilot ated voltage How to Order 00 W U 000 000 000 000 Nil xternal pilot specifications is not available for position dual port valves. 6 VC VC M waterproof connector Symbol Cable length (mm) W 00 W 00 W 000 W 000 W7 000 Light/Surge voltage suppressor U Manual override Nil Thread type Nil F N T c G NT NTF ort size Symbol ort size pplicable series Nil Without sub-plate 0 / 000 0 / 000 000 0 / 000 000 0 / 000 Non-locking push type ush-turn locking slotted type With light/surge voltage suppressor With surge voltage suppressor () ()() C position dual port valve: N.C./N.C. SOL.a () position dual port valve: N.O./N.O. SOL.a () position dual port valve: N.C./N.O. SOL.a () () () () SOL.b () SOL.b () SOL.b () () () () () () () 000 and 000 are not available with dual port valve. --00

Single Valve/Sub-plate Type I67 Compliant Solenoid Valve Specifications Fluid Internal pilot position single operating position dual port valve pressure range position double (Ma) position xternal pilot Operating pressure range operating pressure range position single, double (Ma) position mbient and fluid temperature ( C) Max. operating position single, double frequency position dual port valve (Hz) position Manual override Internal pilot ilot exhaust method xternal pilot Lubrication Mounting orientation Impact/Vibration resistance (ms ) nclosure lectrical entry Coil rated voltage llowable voltage fluctuation ower consumption (W) Surge voltage suppressor Indicator light esponse Time Type of actuation position single position double position position dual port valve Note) ased on dynamic performance test, JIS 7-9. (Coil temperature: 0 C, at rated voltage) ir 0. to 0.7 0. to 0.7 0. to 0.7 00 ka to 0.7 0. to 0.7 0 to 0 (No freezing. efer to page -7-.) Non-locking push type ush-turn locking slotted type Common exhaust type for main and pilot valve ilot valve individual exhaust Not required Unrestricted 0/0 (. to 000 Hz) I67 (ased on IC9) M waterproof connector VC, VC ±0% of rated voltage 0.6 (With indicator light: 0.6) Zener diode L Note) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between. and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) esponse time (ms) (at the pressure of 0. Ma) 000 or less 0 or less or less or less 000 or less 7 or less 9 or less or less 000 or less 6 or less or less 000 0 or less 0 or less or less M Waterproof Connector Wiring Specifications Single solenoid ouble solenoid pins connector (M) plug pins connector (M) plug (COM) (COM) Solenoid Solenoid Solenoid Circuit diagram Solenoid valve side pin wiring diagram Circuit diagram Solenoid valve side pin wiring diagram Note) Solenoid valves have no polarity. --0