VMH. delta-elektrogas.com. Safety shut off valves for gas with hydraulic actuator DN65 DN EE

Similar documents
VMH. www. delta-elektrogas.com. Safety shut off valves for gas with hydraulic actuator DN65 DN200 EE

VML. elektrogas.com. Safety solenoid valves for gas Slow opening and fast closing type DN10 DN80 EE

PCS. Proof of closure switch for safety gas valves. delta-elektrogas.com EE

VF VFH. elektrogas.com. Butterfly valves DN40 DN150 EE155-11/11

Valves. Rapid opening and closing solenoid valves VMR (E1110 rev /11/2012)

VM-R VM-R/OT ELEKTROGAS

SERIES 2000 GAS SAFETY SHUT OFF VALVE

VE4000 & VE5000 SERIES

Valves. Slow opening and rapid closing solenoid valves VM-L (E1111 rev /11/2012)

Black Teknigas. Powerseat Eco Gas Safety Shut-Off Valve. Technical, Installation and Maintenance Details. WattsIndustries.co.uk

VMK Oil burners fuel unit with 2 stages operation

Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

Volumeter TRZ 03-K PRODUCT INFORMATION. Reliable Measurements of Gas

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

VE Series. Class "A" Gas Valves. Product handbook APPLICATION CONTENTS. General. Technical. Installation and operation. Various

Mounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

Type 6213 EV, 6281 EV

B21 Series BASOTROL Gas Valve

Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

SELF-CLEANING FILTER

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

VR400/VR800 series UNIVERSAL GAS VALVES CLASS A SERVO REGULATED COMBINATION VALVES APPLICATION. Contents PRODUCT HANDBOOK. General

STAINLESS STEEL ATEX 2/2 SOLENOID VALVE SPU220-X NF

Solenoid Valve DF-SB-series

STAINLESS STEEL ARES PNEUMATIC ANGLE-SEAT VALVE

Mounting and Operating Instructions EB 5868/5869 EN

KE-M02 configuration Configuratie documentatie documentation KE-M02

VALVES ISO 5599/1, SERIES IPV-ISV

Type 5411, Operating Instructions. Bedienungsanleitung Manuel d utilisation

With regards to safety it is not necessary to check for correct operation.

RMG Meßtechnik GmbH. Publication No E

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves

OPD min max a c max d c. code [ISO 228 G] [mm] [l/min] [barg] [barg] [barg] code [Volts/Hz]

Manually operated safety shut-off valve HSAV HSAV/5

Volumeter. RMG Meßtechnik GmbH. Publication No E

Boiler room components 0459EN February 2018 Manual reset safety pressure switch

Angle seat valve with piston actuator VZXA-...-K

Easytork Solenoid Valve IOM

MULTI-FLUID SOLENOID VALVES 1/8 AND 1/4

Operating Instructions. Valves Atkomatic Series ATEX and Series ATEX Series Series

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Solenoid Valve DF-SA-series

Combi valves PN 16 with flanged connections

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

BALL VALVE - 10 SERIES Electric actuator - El-O-Matic

Electro- Hydraulic Actuator Gas Valves GH-5000

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Ex m Solenoid Operator Type 0519

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

ABV21i and ABV40i Air Actuated Boiler Blowdown Valves

Installation and Operating Instructions DDM-DS11 DDM-DS11-MS1 DDM-DS11-MS2

Metal tube variable area flowmeter for gases, liquids and steam

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3 Edition Product brochure GB AGA

Features PNEUMAT IC VALVES. Pneumatic valves Vip - Pneumatic coaxial valve GENERAL FEATURES CONTROL MEDIA OPERATING MEDIA

BCV30 DN20 - Blowdown Control Valve Installation and Maintenance Instructions

BRONZE ZEUS PNEUMATIC ANGLE-SEAT VALVE

Single-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5

Quarter turn actuator DAPS..R..-F..

VQ400M SERIES CLASS A COMBINATION VALVES INSTRUCTION SHEET APPLICATION

Series 810: 2 Way Angle Body Valves: 1/4 to 3 NPT

2-position electric actuators with Ball valves VBZ ½...11/4

Angle seat valve with piston actuator VZXA-...-K

ONE STAGE GAS BURNERS RDBS SERIES

Valve monitoring system VDK 200 A S02

MBC-300-SE MBC-700-SE MBC-1200-SE MBC-300-N MBC-700-N

p max (see table of performances) Q max (see table of performances) bar Maximum flow l/min see par

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

HYDRONIC LIFT SOLUTION FOR A3 AMENDMENT

Solenoid valves VZWP, servo-controlled

LOW PRESSURE BALANCED VALVE DIAPHRAGM BALANCED

Diaphragm Vacuum Pumps and Compressors

USERS MA UAL Bellow sealed valve Fig.229, 230, 234, 235 Edition: 1/2008

TECHNICAL CATALOGUE BLOCK CHECK AND FOOT VALVES

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Installation & Operation Manual

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

MBC-300-SE MBC-700-SE MBC-1200-SE MBC-300-N MBC-700-N

Shut-off valves SVA-DH, SVA-DL

Old documentation - Only for your information! Product is not available any more!

WARNING Warnings are indicated when mishandling this product might result in death or serious injury to the user.

High Flow Valve Actuation Range. NAMUR Valves G1/4" & G1/2" Piped Valves G1/4" & G1/2" Banjo Valves G1/8" & G1/4"

TECHNICAL CATALOGUE EUROPA CHECK AND FOOT VALVES

BALL VALVE WITH ADA PNEUMATIC ACTUATOR

SITRANS P measuring instruments for pressure

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

TECHNICAL DATA 1-1/2 (dn40)

BUTTERFLY VALVE 27 SERIES Pneumatic actuator - El-O-Matic

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue , Released December 13, 2017

BUTTERFLY VALVE 17 SERIES Gearbox

STAINLESS STEEL ATEX 2/2 SOLENOID VALVE SPU225-X NF

Transcription:

VMH Safety shut off valves for gas with hydraulic actuator DN65 DN300 delta-elektrogas.com EE175-0117

VMH Contents Description.. 3 Features.. 3 Functioning and application. 4 Special versions and optionals 5 Technical specifications 5 Gas flow chart (pressure drop) 7 Standards and approvals. 9 Ordering information. 10 Installation, adjustment and servicing... 11 Elektrogas is a brand name of ELETTROMECCANICA DELTA S.p.A. Via Trieste, 132-31030 Arcade (TV) - Italy Tel +39 0422 874068 Fax +39 0422 874048 www.delta-elektrogas.com info@delta-elektrogas.com Connexion Developments Ltd, Unit 3 Rainbow Court, Armstrong Way, Yate, Bristol, BS37 5NG, England ELETTROMECCANICA DELTA Sales@solenoid-valves.com S.p.A. reserves the right to update or make any technical changes without prior notice. Copyright 2017. All rights reserved. Tel: +44 (0) 1454 334 990 Fax: +44 (0) 1454 326 390 2-16

Description The VMH type valve is a safety shut off valve for gas with hydraulic actuator. It is suitable for air or gas blocking and releasing controls, required in the main pipe of gas power burners, atmospheric gas boilers, industrial kilns and others gas consuming appliances. See Tab. 2 for maximum operative pressure for every model. Features The valves are made of aluminum alloy with a range for connections from DN 65 up to DN 300. Pipe connections meet group 2. Suitable for use with air and non-aggressive gases included in the 1 st, 2 nd and 3 rd families (EN 437). Special versions for aggressive gases. The valve is open only when energized: if, for any reason, power supply goes down, the valve closes immediately (intrinsic safe). Qualified for continuous service (100% ED). Size DN65-80 is equipped with flow rate adjustment. An incorporated fine mesh filter protects the valve seat and disc as well as downstream components and prevents dirty contamination. Provided with G1/4 pressure gauge on two sides in both inlet and outlet chamber to connect manometers, pressure switches, leakage tester or other gas equipments. The actuator is provided with ISO 4400 plug for easy cabling. The protection class is IP65 (EN 60529). The actuator is provided with a led to visualize when it is energized. All components are designed to withstand any mechanical, chemical and thermal condition occurring during typical service. Effective impregnation and surface treatments have been used to improve mechanical sturdiness, sealing and resistance to corrosion of the components. Valves are 100% tested and fully warranted. WARNING This control must be installed in compliance with the rules in force. 3-16

Functioning and application The VMH type valve is a safety shutting device using auxiliary power supply. When it is de-energized, the spring pushes on the seal disc, keeping the gas passage closed. In this condition the inlet chamber is filled with pressurized gas that forces on the disc, improving the seal. When the actuator is powered, the relief valve closes, the pumps starts and the pressurized oil pushes the piston. The disc opens against the combined force of spring and gas pressure. When the disc reaches the end stop, the pump is turned off and only the relief valve is consuming power. If the power supply is shut off, the relief valve opens and the disc closes rapidly, interrupting the gas flow. Fig. 1 shows a sketch of a VMH valve. Fig. 1 This kind of valve is normally installed as safety and regulating device in gas trains, for industrial applications and gas firing systems. Fig. 2 shows an example of installation, in combination with other Elektrogas devices. Ball valve Gas Filter FG Hydraulic valve VMH with PCS Valve leak tester Hydraulic valve VMH Pressure regulator Pressure gauge Pressure switch PSG Solenoid valve VMR-VML Gas network Consumer Fig. 2 WARNING Location and mode of installation must be in compliance with local rules in force. 4-16

Special versions and optionals A switch can be installed as a closed position indicator (see PCS datasheet ). Whole range can be provided with Ex-proof execution for use in Zone 2, according to 94/9/EC Directive (ATEX). The whole range can be supplied in special version suitable for aggressive gases (i.e. biogas, COG). This version is free of nonferrous metals and equipped with special seals. Technical specifications Tab. 1 Connections Flanged PN16 ISO 7005 from DN65 to DN300 Voltage rating (-15%/+10%) Power consumption Ambient temperature 230 VAC or 110 VAC 50/60 Hz 20VA (START 110 W) Only for DN 250 300: 25VA (START 115W) -15 C / +60 C Max. operating pressure see Tab. 2 Flow capacity see Tab. 2 Opening time see Tab. 2 Filter 600 µm, metal mesh Protection class IP65 (EN 60529) Cable gland Materials in contact with gas Plug ISO 4400 with cable gland PG9 Aluminium alloy Brass Stainless steel Plated steel Anaerobic adhesive Nitrile rubber (NBR) Fluoro elastomer (FPM) Polytetrafluoroethylene (PTFE) 5-16

Fig. 3 Tab. 2 Model Conn. Pmax [bar] Opening time * 1 [sec] Flow Kvs [m³/h] Max cycles per hour * 2 Overall dimensions [mm] A B C D Int h Weight [Kg] VMH7 * DN 65 1,6 10..15 83,0 60 200 305 350 536 145 4x18 14 VMH8 * DN 80 1,6 10..15 92,0 60 200 305 350 536 160 8x18 14 VMH9 * DN 100 1,3 15..25 152,0 40 250 350 366 571 180 8x18 18 VMH93 * DN 125 0,5 25..40 250,0 30 310 460 461 671 210 8x18 34 VMH93U DN 125 1,3 25..40 250,0 20 310 460 461 671 210 8x18 34 VMH95 * DN 150 0,5 25..40 315,0 30 310 460 461 671 240 8x23 36 VMH95U DN 150 1,3 25..40 315,0 20 310 460 461 671 240 8x23 36 VMH98 * DN 200 0,2 35..50 476,0 20 370 546 494 730 295 12x23 52 VMH98U DN 200 1,3 35..50 476,0 15 370 546 494 730 295 12x23 52 VMH910U DN 250 1,3 40..60 660,0 15 405 600 560 852 355 12x28 59 VMH912U DN 300 0,6 45..75 970,0 15 460 700 596 923 410 12x28 106 * model with CE 0063CO1798 certificate * 1 opening time depends on ambient temperature, real voltage and inlet pressure * 2 VMH valves are not suitable for very high number of cycles, as used in pulse firing. 6-16

Gas flow chart (Pressure drop) Fig. 4 Formula of conversion from air to other gases V = k GAS V AIR Gas type Specific gravity ρ [Kg/m³] k = Air 1,25 1,00 Natural gas 0,80 1,25 125. ρ GAS Tab. 3 Town gas 0,57 1,48 LPG 2,08 0,77 15 C, 1013 mbar, dry 7-16

When the flow read on the diagram is referred to operating pressure instead of standard conditions, the pressure drop p read on the diagram must be multiplied for the factor: (1+ relative pressure in bar) Example: In the VMH8 - DN80 valve with an air flow of 200 Nm 3 /h there is a pressure drop p = 6,0 mbar. If we consider that 200 m 3 /h is the flow at 1500 mbar of inlet pressure, then the pressure drop to be consider is: p = 6,0x(1+1,5) = 15,0 mbar Usually pressure drop and flow rate for the valves are read from the gas flow diagram. However, the valves can also be chosen in accordance with the characteristic Kvs value as shown in table 2. The selection of the valve requires the calculation of the Kv under the operating conditions. Considering only subcritical pressure drops: p 1 p < 2 Kv can be calculated with the formula: ( t + 273) V ρ Kv = 514 p p 2 where V Kv = flow rate [Nm 3 /h] = flow factor [m 3 /h] ρ = density [Kg/m 3 ] p1 p2 p t = absolute inlet pressure [bar] = absolute outlet pressure [bar] = differential pressure p1-p2 [bar] = media temperature [ C] To the Kv value calculated from operating conditions we add an allowance of 20%, to obtain the minimum Kvs value which the valve should have: Kvs > 1,2 Kv Valve must be selected considering the following: - Pressure drops p 0,1p1 are recommended and p > p1/2 are always unadvisable - Flow velocities w 15 m/s are recommended and w > 50 m/s are always unadvisable. 8-16

Standards and approvals The valves are designed and manufactured according to European Directive on Gas appliances 2009/142/EC and the certification has been issued by the notified body: Kiwa Nederland B.V. Wilmersdorf, 50 7300 AC Apeldoorn Reg-n CE 0063CO1798 (*) The products with operating pressure superior 0.5 bar comply with the Pressure Equipment Directive 2014/68/UE (ex 97/23/CE) and the certification has been issued by the notified body: CSI Spa 20030 Senago MI I Reg-n CE 0497 (PED/0497/2638/13) The following standards/technical specifications have been fulfilled: - Electromagnetic Compatibility (2014/30/UE) - Low Voltage Directive (2014/35/UE) - Rohs II (2011/65/UE) - Atex (2014/34/UE) when shown upon the product. Quality Management System is certified according to UNI EN ISO 9001 and the monitoring is carried out by the notified body: Kiwa Cermet Italia Spa Reg.-n 11989-A (*) not applicable to all models, see Tab. 2 9-16

Ordering Information VMH 8 - - Tab. 4 Valve type VMH Connections size and operative pressure 7 = DN65 1.6bar 8 = DN80 1.6bar 9 = DN100 1.3bar 93 = DN125 0.5bar 93U = DN125 1.3bar 95 = DN150 0.5bar 95U = DN150 1.3bar 98 = DN200 0.2bar 98U = DN200 1.3bar 910U = DN250 1.3bar 912U = DN300 0.6bar Supply voltage - = 230V 50/60Hz B = 110V 50/60Hz Special version J = version for bio gas K = version for coke gas Example: VMH93.BK : valve DN125, 110V suitable for bio and coke gas Optionals available: explosion-proof execution, PCS (closed position indicator switch), others on request. They must be ordered with their code. 10-16

Installation, adjustment and servicing To assure a proper and safe operation, as well as a long life of the valve, installation procedure and periodical servicing are very important topics and the following instructions should be always fulfilled. IMPORTANT: before proceeding with the installation, ensure that all the features of your system comply with the specifications of the valve (gas type, operating pressure, flow rate, ambient temperature, electrical voltage, etc.). CAUTION Shut off the gas supply at the main manual shut-off valve and disconnect electrical power to the valve before proceeding installation or servicing. Fig. 5 PIPING CONNECTION For an easier handling the actuator can be removed from the valve body (unscrew the hex head screws at the base of the actuator and pay attention to the O-ring between actuator and valve) - Check correspondence of flow direction with arrow printed on valve body. Pay attention: o o valve may be mounted in horizontal or vertical position; in case of vertical pipe, the flow direction should be from bottom to top in case of vertical pipe the actuator must be oriented with the plug upward. 11-16

- Check correct alignment of connecting pipes. - Ensure that installing area is protected from rain and water splashes or drops. - Remove the end caps and make sure no foreign body is entered into the valve during handling. - Position the gasket or sealing agent on the flanges and insert the bolts with washers. - Screw the nuts tightening them crosswise and using proper tools only. Avoid overtightening and mount tension free. - If the actuator has been removed, check the correct position of the O-ring and position the actuator on its connection flange (in case of vertical pipe the actuator must be oriented with the plug upward). - Fit all the screws with washers and then screw them crosswise using a proper tool. Avoid overtightening (max 10Nm). Tab. 5 Tab. 5 shows the maximum values of bending moment (Fmax) and screws driving torque (Cmax), according to Connections Fmax Cmax EN161. (Nm) t<10 s (Nm) DN65 1600 50 DN80 2400 50 DN100 5000 80 DN125 6000 160 DN150 DN200 DN250 7600 160 DN300 Fig. 6 12-16

ELECTRICAL CONNECTION (IEC 730-1) - Using a screwdriver remove the plug from the actuator. - Unscrew the gland-nut (G) and remove the washer (F) and grommet (E). - To remove the terminal block (A) from the plug housing (C), remove the gasket (B) and extract the screw (D) completely, then insert a flat screwdriver into the slot located on edge and pull it. Fig. 7 - Insert the cable in to the gland-nut, washer, grommet and then into the plug housing. - Connect power cables to the terminal block according to printed designation. - Pull back the cable and insert the terminal block into the housing. - Screw back the gland-nut, make sure that the grommet is locked on the cable. - Insert the screw and gasket into the housing and screw back the plug on the coil. It is recommended not to power the actuator before it is correctly install on the valve, because serious damage can result. The continuous service (100% ED) causes inevitable actuator heating, depending of working environment. This situation is absolutely normal and does not have to worry. To improve the actuator cooling, install the valve allowing free air circulation. In order to avoid injury, after a prolonged period of operation, avoid direct contact with the actuator. WARNING Make sure all gaskets are used properly. After mounting perform a leak test with the valve open (max. testing pressure: 1.5 Pmax) and a functional test (at normal working pressure). FLOW RATE ADJUSTMENT (Vmax only VMH 7-8 DN65 - DN80) Flow rate may be adjusted from 0 cubic meters/h to the maximum (only 2 ½-3 ). 1) Remove the cap on the bottom of the valve. 2) Using a 6 mm Allen wrench, set the flow regulation screw. Turn wrench clockwise to decrease or counter-clockwise to increase flow rate (factory setting is max. flow rate). Reducing the flow is easier when valve is not powered. 3) When adjustment is completed, screw back the cap. www.solenoid-valves.com 13-16

Fig. 8 WARNING Adjustments below 40% of capacity are unadvisable because they may cause turbulence. PCS (closed position indicator switch) mounting All VMH valve can be equipped with PCSHP (closed position indicator switch for VMH actuator). This item has to be purchased separately. Its mounting is very easy: - with a 5mm Allen wrench remove the 1/8 plug on the side of the actuator and iintroduce the rod of PCS inside 1/8" hole and screw the switch with O-ring. - Tighten using open-ended spanner WAF15. Avoiding overtightening. - For an easier handling the actuator can be removed from the valve body (unscrew the hex head screws at the base of the actuator and pay attention to the O-ring between actuator and valve) - Electrical connection and switching point adjustment in accordance with PCS instruction sheet. Fig. 9 14-16

To maintain a good performance of the system, almost once a year, an external inspection of the valve is recommended. Due to seals aging, to ensure safe operation, we recommend valve replacement after 10 years from the date of manufacture stamped on the product. EXTERNAL INSPECTION - Turn off all power before servicing any part of the system. - Check the conditions of the plug. If gasket is deteriorated, replace it with a new one. - Check the electrical connections are clean, dry and correctly tightened. - Check the conditions of pipe connections: cover them with a soap solution and check for leakages. - Check the proper operation of the valve: power the actuator and verify that valve opens, then, turn off power and check the closing function. - Power the actuator, when valve is open, the pump stops (noise reduction). In normal condition the pump doesn t restart more than 3 times in 20 minutes. If the pumps restarts more frequently, it is necessary to replace the actuator. INTERNAL INSPECTION Make this inspection when the valve does not work properly only. To make an internal inspection of the valve, do the following: - Shut ball valve upstream the system and make sure no pressure is inside the valve. - Using an Allen key, remove the screws (1) on the counter flange (2), in cross way. The gas in the valve will come out during this step. Pay attention to the spring inside the valve: they push the counterflange. - Check the main O-ring(3). If it s necessary, replace it with an identical one. - Blow the assembly of counter flange spring disc (2) with compressed air. Check the spring is corrosion free. Don t try to disassemble it: this operation can be very dangerous. - Check the conditions of the sealing gasket. If gasket is deteriorated, replace it with a new one. - Clean the sealing lip with a clean cloth. Do not use tools, because a lip damage could result. - Remove the filter (4) and blow it with compressed air. - Reassemble the valve following the inverse sequence. When the reassembly is finished, verify the correct sealing between the counter flange and the valve body: - Open ball valve to restore pressure into the valve. Fig. 10 - Apply a soap solution between the counter flange and the valve body and check for leakages. 15-16

ACTUATOR REPLACEMENT Before starting with actuator replacement, make sure it is the cause of failure. To replace the actuator do the following: - Make sure an identical spare part is available. - Switch off power supply and remove the plug (8). - Remove the connecting screws at the base of the actuator (6) and remove the damaged actuator. Pay attention to the O-ring between actuator and valve (5). - Reassemble the new one with inverse sequence. If necessary, replace the plug also. WARNING To prevent product damage and dangerous situations, read the Installation and Service Instructions carefully. Turn off all power before servicing any part of the system. Perform leak and functional tests after mounting. Use all gaskets properly (void warranty). All wiring must be in compliance with local and national codes. Make sure all works are performed by qualified technicians only and in compliance with local and national codes. Connexion Developments Ltd Solenoid Valves (UK) Ltd Unit 3, Rainbow Court Armstrong Way, Yate Bristol, BS37 5NG England T: +44 (0) 1454 334 990 F: +44 (0) 1454 326 390 E: sales@solenoid-valves.com www: solenoid-valve.world 16-16