Level Probe multicap DC 16

Similar documents
Level Probes multicap T DC 12 TE multicap T DC 11/16/21/26 TEN/TES

Level Probes multicap DC 11/16/21/26 EN multicap DC 11/16/21/26 ES

Level Probes multicap T DC 12 TA multicap T DC 11/16/21/26 TAN/TAS

Level Limit Switch liquiphant FTL 365 / FTL 366

Level Limit Switch liquiphant FTL 360 / FTL 361

Level Limit Switch soliphant II FTM 30 (D/S), FTM 31 (D/S), FTM 32 (D/S)

Soliphant II FTM30(D/S)/31(D/S)/32(D/S)

Vibration Limit Switch liquiphant M FTL 51 C

Level Limit Switch soliphant FTM 930/931/932/ Z

Rod probe 11375Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids

Level limit switch Series RF 3000 Selection list

Soliphant T FTM260. Technical Information. Level limit switch Cost-effective vibration limit switch for fine-grained solids

Thermowell for temperature sensors omnigrad M TW 13

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Metal tube variable area flowmeter for gases, liquids and steam

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC500. 5/282 Siemens FI Overview.

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Continuous level measurement Capacitance transmitters

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

RTD Temperature Sensor omnigrad T -TR 470

Operating Instructions. VEGASWING 61, 63 with oscillator SW E60N (EX)

MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC

OPTISWITCH 4000/5000. Vibration level switches for liquids

Indumax P CLS50. Technical Information. Highly resistant, inductive conductivity sensor for standard, hazardous and high-temperature applications

Liquicap M FTI51, FTI52

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57

Level Measurement Continuous level measurement - Capacitance transmitters

Ultrasonic Measurement prosonic FDU 80 86

Function. Orifice (mm) NBR (Perbunan) 0 EPDM 1 FKM (Viton) 2 FFKM (Kalrez) / O-ring FKM 4

SITRANS F M. Flow sensor MAG 1100 F 3/59

CAPACITIVE LEVEL SWITCHES. Capacitive switch catalogue HYC-CSC01 Elect. Iss. 01

Level Measurement. Point level measurement Capacitance switches. Pointek CLS300 Standard. 5/42 Siemens FI Overview.

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam

OPTISWITCH 6500 C Technical Datasheet

Solicap M FTI55, FTI56

Thermowell for temperature sensors omnigrad M TW 11

Flow Measurement SITRANS F M

Plastic tube variable area flowmeter for liquids and gases

Point level measurement Capacitance switches

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

SITRANS F M flow sensors 711/A and 711/911E

Electromagnetic Flow Monitor magphant

p Additional dimensions see section dimensions.

FS10. Vertically-Mounted Magnetic Float Level Sensor. Level Measurement and Monitoring. reliable and robust, heavy-duty technology

2/2-way-Globe Valve with stainless steel design for media up to +180ºC, DN 13-50

Magnetic Float Switches horizontal 1003-h

Level Measurement Point level measurement - RF Capacitance switches

Overview. Specifications. Applications

Conductivity Measurement CLM 280

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator

Solenoid Valve Island Type 3965

X=ATEX BUTTERFLY VALVES + SA & NA ACTUATOR

BUTTERFLY VALVES + NA ELECTRIC ACTUATOR

2/2-way Angle-Seat Valve for medium up to +180 C, threaded port connection, DN 15-65

Micro Motion F-Series Coriolis Flow and Density Meters

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

STAINLESS STEEL ARES PNEUMATIC ANGLE-SEAT VALVE

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Safety Relief Valves Commanche Techmatic Controls

VALVE WITH UV ACTUATOR

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug

Flow Measurement SITRANS F C. Flow sensor MASS 2100 DI 3 to DI 40. 4/180 Siemens FI

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Cleanfit W CPA450. Technical Information. Retractable assembly for 12 mm sensors for DO/pH/ORP measurement

Level switches Series LC40 Float level switch for liquids

7829 Visconic industrial viscosity transmitter on line real time viscosity measurement

TORRIX Magnetostrictive level sensor

Differential pressure gauge with diaphragm

RHM30. Coriolis Mass Flow Meter for Plant and Loading Flows. Features. Applications. Benefits

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

SITRANS T measuring instruments for temperature

For single and double operated actuators. Exhaust air recirculation (3/2 way function)

RHM04. Compact Coriolis Flow Sensor With Enhanced Performance. Features. Applications. Benefits

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

BRONZE ZEUS PNEUMATIC ANGLE-SEAT VALVE

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator

Pressure transmitter JUMO dtrans p02

SENSOFIT RET 5000 Technical Datasheet

Flow switches Series AD/VH

Accessories Cable glands

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

OPTISWITCH 6500 C Technical Datasheet

Process pressure. Overview 168 VEGABAR series VEGABAR series Accessory 184. Process pressure VEGABAR

Cleanfit H CPA475. Technical Information. Retractable assembly for ph, ORP measurement under sterile conditions

Solenoid Valves Type 3963

NIVOSWITCH R-400/R-500

Limit Switch Type 4747

RHM015. Ultimate Performance Coriolis Mass Flow Meter for Critical Ultra Low Flow Applications. Features. Applications. Benefits

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

RHM40. Coriolis Mass Flow Meter for Demanding Applications. Features. Applications. Benefits

BUTTERFLY VALVES + UM ELECTRIC ACTUATOR

RTD Temperature Sensor omnigrad M TR 15

Magnetic float switch For vertical installation Model FLS

Transcription:

Technical Information TI 096F/00/en Operating Instructions 017186-1000 Level Probe multicap DC 16 Partially insulated rod probes Applications The Multicap DC 16 probe is primarily designed for limit detection in liquids. The wide selection of corrosion-resistant materials used ensures that it can also withstand extremely corrosive products. The tried-and tested, rugged construction is gas-tight for pressures from vacuum to 100 bar (1450 psi) gauge. Seal and materials enable it to be used with operating temperatures in the vessel of 80 C up to +200 C ( 110 F to +390 F). Your benefits Optimum adaptation to your application thanks to a wide range of process connections and practical variations = reliable function at a cost-effective price Protection against condensation in the nozzle = reliable function even with condensation Active build-up compensation for limit detection = constant and accurate switchpoint even with heavy build-up on the probe, no cleaning or recalibration required

Measuring System The measuring system consists of: Multicap DC 16 probe EC... electronic insert in the probe housing Nivotester FTC (Z) level limit detector or Silometer FMC (Z) level transmitter. For limit detection in liquids with heavy build-up or for detecting interface layers, the measuring system consists of: Multicap DC 16 probe with active build-up compensation EC 16 Z electronic insert FTC 520/521 Z or FTC 470/471 Z level limit switch. The limit input of the Silometers FMC 671 Z can also be connected. Measuring system and application EC... EC... Silometer FMC... Nivotester FTC... Level limit detection L00-DC16xxxx-14-05-xx-xx-001 Continuous level measurement L00-DC16xxxx-14-05-xx-xx-002 Three examples for the use to Multicap DC 16 probes: 1) Probe with a combination of screening and active build-up compensation for separation layer detection 2) Probe with screening against condensation in the ounting pipe in the tank roof 3) Probe with active build-up compensation for reliable limit detection despite extreme build-up 1 2 3 L00-DC16xxxx-14-05-xx-xx-003 2 Endress+Hauser

Separate mounting of the electronic insert with an excessively high ambient temperature for the probe head housing > 80 C EC... HTC... Nivotester FTC... L00-DC16xxxx-14-05-xx-xx-004 Certified applications Please note all specifications in the certificates and appropriate regulations as well as the instructions given in this Technical Information. Operating Principle The probe and vessel wall or counter electrode form a capacitor with a defined low capacitance when the probe is in air. As soon as material covers the probe a parallel circuit is formed consisting of a much larger capacitance and the resistance of the material the impedance. In the case of limit detection with ially insulated probes, this means that for materials with conductivities greater than a given, very low threshold, any change in dielectric constant, and thus of conductivity, has no effect on the switchpoint. On the other hand, this means that it is not possible to use ially insulated probes for continuous level measurement in electrically conducting materials. Screening on the probe prevents effects caused by build-up of material or condensation in the vicinity of the process connection. Probes with active build-up compensation for limit switching cancel out effects of build-up on the probe. Partial Probe rod in air L00-DC16xxxx-05-05-xx-en-001 Simplified circuit diagram showing capacitance measurement with ly insulated probes R C A in medium C Endress+Hauser 3

Probe Selection Here are just a few notes on the various designs for the ially insulated Multicap DC 16 probe 1. Probe for limit detection in conductive liquids 1. for high viscosity liquids for bulk solids 2. Probe with ground tube for non-conductive liquids for use in agitator vessels 2. 3. Probe with screening for long nozzles for condensation on the roof of the vessel for build-up on the vessel wall 3. 4. Probe with active build-up compensation for limit detection with heavy (conductive) build-up on the probe. The active build-up compensation of the 4. Multicap DC 16 probe is always gas-tight due to the self-adjusting tapered gasket. A wide range of corrosion-resistant materials ensures that they can be used with aggressive products. 5. 5. Probe with gas-tight gland for liquefied gas tanks (required in Germany) to prevent condensation forming in the probe on extreme temperature variations. L00-DC16xxxx-03-05-xx-xx-000 See also temperature graphs overleaf. 6. Probe with temperature spacer for an extended range of operating temperatures in the vessel. See also temperature graphs overleaf. 7. Probe without electronic insert for high temperatures in the probe housing: Use electronic insert in separate housing. See also temperature graphs overleaf. 8. Probe with protective cover (accessory) to prevent condensation forming in the aluminium standard housing. 6. 7. 8. Further variations outside the product tank L00-DC16xxxx-03-05-xx-xx-001 4 Endress+Hauser

Electronic Insert Separate or integrated? Information is provided by the graphs on the right. The horizontal axis is the operating temperature T B in the vessel. The vertical axis is the ambient temperature T U of the probe housing (in C). A 80 T U 40 0 80 40 0 40 80 120 160 200 40 T B Do the temperatures lie in the grey area of graph A? The electronic insert may be mounted in the housing of any probe. Do the temperatures lie in the grey areas of graph B? The electronic insert may be mounted in the housing of a probe with a temperature spacer or gas-tight gland; or it may be mounted in a separate housing. B C 80 T U 40 0 80 40 0 40 80 120 160 200 40 120 80 T U T B Do the temperatures lie in the grey areas of graph C? The electronic insert should be mounted in a separate housing. 40 0 80 40 40 0 40 80 120 160 200 T B Do the temperatures lie in the grey area of graph D? Use a probe with a temperature spacer or a gas-tight gland and mount the electronic insert in a separate housing. D 160 120 80 40 T U 0 80 40 0 40 80 120 160 200 40 T B x C = (x 1.8 + 32) F L00-DC21xxxx-05-05-xx-xx-001 Application range of the various types as a function of operating and ambient temperature Endress+Hauser 5

Dimensions in mm (100 mm = 3.94 in / 1 in = 25.4 mm) 60 AF approx. 135 approx. 160 G 1 ½ A or 1 ½ - 11½NPT ø16 ø12 25 active probe rod ø16 ø12 left: Multicap DC 16 with threaded boss right: Multicap DC 16 with flange L00-DC16xxxx-06-05-xx-en-001 approx. 30 (approx. 40) 15 (25) 60 AF approx. 135 approx. 15 ø8 approx. 160 ø8 max. ø43 ø38 spacer every 1000 mm active probe rod max. ø43 ø38 spacer every 1000 mm left: Multicap DC 16 with threaded boss G 1 ½ A and ground tube (Dimensions in brackets for the threaded boss with 1 ½ -11 ½ NPT) right: Multicap DC 16 with flange and ground tube L00-DC16xxxx-06-05-xx-en-002 60 AF approx. 135 approx. 160 G 1 ½ A or 1 ½ - 11 ½ NPT ø16 ø12 25 100 min. 50 150 active probe rod ø16 ø12 100 min. 50 150 active probe rod left: Multicap DC 16 with threaded boss and active build-up compensation right: Multicap DC 16 with flange and active build-up compensation L00-DC16xxxx-06-05-xx-en-003 6 Endress+Hauser

Dimensions for Probes with Screening 60 AF approx. 102 approx. 120 G 1 ½ A or 1 ½ - 11 ½ NPT max. ø43 ø16 ø12 25 screening L3 active probe rod max. ø43 ø16 ø12 screening L3 active probe rod left: Multicap DC 16 with threaded boss and screening right: Multicap DC 16 with flange and screening L00-DC16xxxx-06-05-xx-en-004 60 AF approx. 102 approx. 120 L3 + approx. 8 mm G 1 ½ A or 1 ½ - 11 ½ NPT ø8 max. ø43 ø38 25 screening L3 spacer every 1000 mm active probe rod L3 + approx. 8 mm ø8 max. ø43 spacer every 1000 mm ø38 screening L3 active probe rod left: Multicap DC 16 with threaded boss, screening and ground tube right: Multicap DC 16 with flange, screening and ground tube L00-DC16xxxx-06-05-xx-en-005 G 1 ½ A or 1 ½ - 11 ½ NPT max. ø43 ø16 ø12 60 AF 25 screening 100 L3 min. 50 150 active probe rod approx. 102 max. ø43 ø16 ø12 screening min. 50 100 L3 150 active probe rod approx. 120 left: Multicap DC 16 with threaded boss, screening and active build-up-compensation right: Multicap DC 16 with flange, screening and active build-up-compensation L00-DC16xxxx-06-05-xx-en-006 Endress+Hauser 7

Dimensions of Other Process Connections and Parts L L approx. 159 approx. 160 left: Multicap DC 16 with sanitary thread DN 50 (DIN 11851) right: Multicap DC 16 with 2" Triclamp coupling L00-DC16xxxx-06-05-xx-en-007 60 AF approx. 183 (approx. 148) approx. 210 (approx. 168) G 1½ A or 1½ - 11½ NPT 25 left: Multicap DC 16 with threaded boss and gas-tight gland right: Multicap DC 16 with flange and gas-tight gland L00-DC16xxxx-06-05-xx-en-008 60 AF approx. 200 (approx. 165) approx. 225 (approx. 183) G 1½ A or 1½ - 11½ NPT 25 left: Multicap DC 16 with threaded boss and temperature spacer right: Multicap DC 16 with flange and temperature spacer L00-DC16xxxx-06-05-xx-en-009 (Dimensions for the DC 16 with screening are shown in brackets) 8 Endress+Hauser

6 5 4 3 2 1 Multicap DC 16 Transport, Unpacking To avoid damage to the probe, remove the packaging on-site just before mounting. The uninsulated section of probes with active build-up compensation is covered with plastic webbing. This protection should be removed prior to mounting. Compare the code on the nameplate of the probe with the product designation on Page 13 to ensure that the correct probe has been delivered. Check the probe length. The probes can be shortened easily by sawing. Minimum lengths for the probe rod and are given in the project information. Installation Probe with parallel thread G 1 ½ A: Use the elastomer/fibre seal provided or any other chemically resistant seal which can withstand temperatures up to 300 C (570 F). Probe with tapered thread 1 ½ - 11 ½ NPT: If required, wrap suitable sealing material around the thread. Probe with flange connection: Use a sealing material suitable for the application. If the flange is PTFE-clad, then this is generally a suitable seal up to the permitted operating pressure. Make sure that the probe is not damaged when sliding the probe through the threaded sleeve or nozzle with counter-flange. When tightening, turn the probe with threaded boss at the hex nut only; not at the housing! For probes with the G 1 ½ A thread and seal: a torque of 300 Nm is sufficient to seal tight against a pressure in the vessel of up to 50 bar (725 psi). a torque of 530 Nm is sufficient to seal tight against a pressure in the vessel of up to 100 bar (1450 psi). Maximum admissible torque: 600 Nm A polypropylene threaded boss with rubber seal may only be tightened using a max. torque of 7 Nm (1 Nm = 0.74 ft lbs). Rotating the Housing 1 1 1 2 3 4 5 6 + EC 16 Z 6 2a 2b 2c L00-DC21xxx-11-05-xx-xx-001 1) The housing can be rotated after the 3 nuts have been loosened 2) Tighten electronic insert (a) with the central slotted nut (b) leaving space (c) for the connecting cable The housing can be rotated if the cable gland is pointing in the wrong direction after mounting. To loosen: Unscrew the housing cover Unscrew the central nut (slotted nut) in the electronic housing Remove the electronic insert from the housing Slightly loosen the 3 nuts (7 AF), see Figur. Endress+Hauser 9

To rotate: To tighten: The housing can now be rotated in any direction. When mounting the probe from the side, the cable entry should be facing downwards so that no moisture can enter. Securely tighten the 3 nuts in the housing so that the housing is tight against the hex nut. Insert the electronic insert and securely tighten the central nut so that it does not become loose. Ensure that the cable gland remains free. Connection Refer to the appropriate Technical Information concerning the electronic insert EC... used in the probe housing. In the case of the heavy duty housing, the connection diagram corresponds to that of the built-in electronic insert. If is important that no moisture enters the probe housing during storage of the probe, connection of the electronic insert and during operation. Always tighten the housing cover and cable gland securely. If the probe is installed in a plastic tank, connect the ground terminal of the probe to the counterelectrode using a short cable. Replacing components Mounting without electronic insert Exchange of electronic inserts After the defective electronic insert has been removed and the replacement properly installed, the instrument must be recalibrated and checked for correct function. If fully insulated multicap probes are mounted in explosion hazardous areas without the electronic insert, and there is a risk of dangerous electronic discharges, then the probe terminal in the housing must be short-circuited with the ground terminal. Technical Data Operating data Permitted operating pressures p e and temperatures T B. Temperature T B : x C = (x 1.8 + 32) F Pressure p e : 1 bar = 14.5 psi See the following graphs for the relationship between operating pressure and temperature: 100 p e bar 80 60 40 20 +20 bar up to 1 bar 50 0 50 100 150 200 T B C p e bar 50 40 30 20 10 +2 bar up to 1 bar 50 0 50 100 150 200 T B C L00-DC16xxxx-05-05-xx-en-002 Insulation PTFE or PFA Does not apply to: probes with active build-up compensation Monel Insulation PTFE or PFA Applies to probes with active build-up compensation L00-DC16xxxx-05-05-xx-en-003 10 Endress+Hauser

p e bar 20 10 +2 bar up to 1 bar 80 60 40 20 0 20 40 60 T B C p e bar 6 4 2 0 20 1 0 20 40 60 80 +0 bar up to 1 bar 100 T B C Insulation PE L00-DC16xxxx-05-05-xx-en-004 L00-DC16xxxx-05-05-xx-en-005 Probe with polypropylene threaded boss and rubber seal Capacitance values of the probe Ground capacitance: approx. 30 pf Other capacitance values Gas-tight gland: approx. 20 pf Temperature spacer: approx. 20 pf Active build-up compensation: approx. 10 pf Screening: approx. 3 pf/100 mm Probe is 250 mm from a conductive vessel wall Insulated probe rod: approx. 1.3 pf/100 mm Uninsulated probe rod: approx. 1.3 pf/100 mm Probe in ground tube Insulated probe rod: approx. 5.5 pf/100 mm Plain probe rod: approx. 5 pf/100 mm Lateral load bearing capacity of the probe see graphs on the right max. 30 Nm with active build-up compensation with screening max. 45 Nm max. 60 Nm with screening and active build-up compensation max. 70 Nm with ground tube max. 300 Nm with screening and ground tube max. 300 Nm 1 Nm = 0.74 ft lbs Lateral load bearing capacity for the probe at 20 C (70 F) and static load L00-DC16xxxx-03-05-xx-en-001 Probe lengths (100 mm = 3.94 in) Total length of probe: L max. 6000 mm Length of screening: L3 min. 100 mm, max. 4000 mm Length of active probe rod: max. 4000 mm Length of ial : min. 75 mm, max. probe rod length minus 50 mm Length of active build-up compensation: always 150 mm from where the probe rod leaves the process connection or screening Length tolerances up to 1 m: +0 mm, 5 mm up to 3 m: +0 mm, 10 mm up to 6 m: +0 mm, 20 mm Endress+Hauser 11

Process connection standards Parallel thread G 1 ½ A: DIN ISO 228/I, with sealing ring 48 x 55 conf. to DIN 7603 Tapered thread 1 ½ - 11 ½ NPT: ANSI B 1.20.1 DIN flanges: see flange table ANSI flanges: ANSI B 16.5 Sanitary thread: DIN 11851 Triclamp coupling: ISO 2852 Materials Most material specifications are given in the product structure on Page 13 Aluminium housing: cast aluminium AlSi 12, resistant to sea water, EP lacquered Aluminium housing, coated: in fluoropolymer Sealing between housing and process connection: EPDM Sealing for housing cover: O-ring in EPDM Temperature spacer: SS 304 H Gas-tight gland: SS 304 H Sealing ring for process connection G 1 ½ A: elastomer/fibre, non-asbestos, resistant to oils, solvents, steam, weak acids and alkalis up to 300 C and 100 bar (570 F and 1450 psi) Cable entrys: standard Pg in nickel-plated brass with NBR seal for cable diameter 7...10 mm; Protection IP55; ambient temperature up to 100 C (210 F) Water-tight Pg in polyamide with neoprene/cr seal for cable diameter 7...12 mm; Protection IP66; ambient temperature up to 80 C (180 F) See product structure for housing variations. Certificates EC-Type-examination certificate PTB 98 ATEX 2215 X 4 0 II 1/2 G, EEx ia IIC/B T6 XA 024F/00/a3 EC-Type-examination certificate PTB 98 ATEX 2215 X 4 0 II 1/2 G, EEx ia IIC/B T6 XA 080F/00/a3 DIBt test report to 19 WHG, overspill protection with continuous level measurement (for Germany) ZE 210F/00/de DIBt test report to 19 WHG, for overspill protection with level limit switch (for Germany) ZE 211F/00/de 12 Endress+Hauser

Product Structure Product structure Multicap DC 16 Design Basic weight DC 16 Partialy insulated rod probe 2,0 kg 10 Certificate A ATEX II 1/2 G EEx ia IIC T6 D For non-hazardous areas Overspill protection to WHG F ATEX II 1/2 G EEx ia IIC T6 Overspill protection to WHG H ATEX II 3 G EEx na II T6 Overspill protection to WHG R For non-hazardous areas Y Special version 1 ATEX II 1/2 G EEx ia IIB T6 2 ATEX II 1/2 G EEx ia IIB T6 Overspill protection to WHG 5 ATEX II 1/2 G EEx ia IIC* T6 Overspill protection to WHG 6 ATEX II 1/2 G EEx ia IIC* T6 7 ATEX II 3 G EEx na II* T6 *) With note: "Avoid electrostatic charge" 20 Electronic insert Additional weight A Electronic insert not selected - - B with EC 61 Z 3-wire insert 0,2 kg C with EC 11 Z 3-wire Tx 33 khz 0,2 kg D with EC 72 Z 3-wire Tx 1 MHz 0,2 kg E with EC 17 Z 2-wire PFM 0,2 kg F with EC 16 Z 2-wire PFM 0,2 kg G with EC 27 Z 2-wire PFM 0,2 kg H with EC 37 Z 2-wire PFM Tx 33 khz 0,2 kg I with EC 47 Z 2-wire PFM Tx 1 MHz 0,2 kg Y Special version 30 Process connection, material AE1 2" 150 lbs RF Flange ANSI B16.5 steel 1,6 kg AE2 2" 150 lbs RF Flange ANSI B16.5 316Ti 1,6 kg AE3 2" 150 lbs RF Flange ANSI B16.5 PTFE >316Ti 1,6 kg AE4 2" 150 lbs RF Flange ANSI B16.5 Alloy B >316Ti 1,8 kg AE5 2" 150 lbs RF Flange ANSI B16.5 Alloy C >316Ti 1,8 kg AE6 2" 150 lbs RF Flange ANSI B16.5 Monel >316Ti 1,8 kg AG2 2" 300 lbs RF Flange ANSI B16.5 316Ti 3,0 kg AL1 3" 150 lbs RF Flange ANSI B16.5 steel 3,2 kg A 3" 150 lbs RF Flange ANSI B16.5 316Ti 3,2 kg AL3 3" 150 lbs RF Flange ANSI B16.5 PTFE >316Ti 3,2 kg AN2 3" 300 lbs RF Flange ANSI B16.5 316Ti 5,6 kg AP1 4" 150 lbs RF Flange ANSI B16.5 steel 5,4 kg AP2 4" 150 lbs RF Flange ANSI B16.5 316Ti 5,4 kg AP3 4" 150 lbs RF Flange ANSI B16.5 PTFE >316Ti 5,4 kg AP4 4" 150 lbs RF Flange ANSI B16.5 Alloy B >316Ti 5,8 kg AP5 4" 150 lbs RF Flange ANSI B16.5 Alloy C >316Ti 5,8 kg AP6 4" 150 lbs RF Flange ANSI B16.5 Monel >316Ti 5,8 kg AR2 4" 300 lbs RF Flange ANSI B16.5 316Ti 7,3 kg AU2 6" 150 lbs RF Flange ANSI B16.5 316Ti AW2 6" 300 lbs RF Flange ANSI B16.5 316Ti BG1 DN 50 PN 25/40 B Flange DIN 2527 steel 3,0 kg BG2 DN 50 PN 25/40 B Flange DIN 2527 316Ti 3,0 kg BG3 DN 50 PN 25/40 Flange DIN 2527 PTFE >316Ti 3,0 kg BM1 DN 80 PN 10/16 B Flange DIN 2527 steel 4,5 kg BM2 DN 80 PN 10/16 B Flange DIN 2527 316Ti 4,5 kg BM3 DN 80 PN 10/16 Flange DIN 2527 PTFE >316Ti 4,5 kg BQ1 DN 100 PN 10/16 B Flange DIN 2527 steel 5,4 kg BQ2 DN 100 PN 10/16 B Flange DIN 2527 316Ti 5,4 kg BQ3 DN 100 PN 10/16 Flange DIN 2527 PTFE >316Ti 5,4 kg CG2 DN 50 PN 25/40 C Flange DIN 2527 316Ti 3,0 kg CG4 DN 50 PN 25/40 Flange DIN 2527 Alloy B >316Ti 3,2 kg CG5 DN 50 PN 25/40 Flange DIN 2527 Alloy C >316Ti 3,2 kg CG6 DN 50 PN 25/40 Flange DIN 2527 Monel >316Ti 3,2 kg CM2 DN 80 PN 10/16 C Flange DIN 2527 316Ti 4,5 kg Endress+Hauser 13

30 Process connection, material CM4 DN 80 PN 10/16 Flange DIN 2527 Alloy B >316Ti 4,8 kg CM5 DN 80 PN 10/16 Flange DIN 2527 Alloy C >316Ti 4,8 kg CM6 DN 80 PN 10/16 Flange DIN 2527 Monel >316Ti 4,8 kg CQ2 DN 100 PN 10/16 C Flange DIN 2527 316Ti 5,4 kg CQ4 DN 100 PN 10/16 Flange DIN 2527 Alloy B >316Ti 5,8 kg CQ5 DN 100 PN 10/16 Flange DIN 2527 Alloy C >316Ti 5,8 kg CQ6 DN 100 PN 10/16 Flange DIN 2527 Monel >316Ti 5,8 kg FG2 DN 50 PN 40 F Flange DIN 2512 316Ti 3,0 kg FM2 DN 80 PN 16 F Flange DIN 2512 316Ti 4,5 kg FQ2 DN 100 PN 16 F Flange DIN 2512 316Ti 5,4 kg GN1 1 ½" NPT Thread ANSI steel - - GN2 1 ½" NPT Thread ANSI 316Ti - - GN4 1 ½" NPT Thread ANSI Alloy B - - GN5 1 ½" NPT Thread ANSI Alloy C - - GN6 1 ½" NPT Thread ANSI Monel - - GRB G 1 ½ A Thread ISO 228 PP - - GR1 G 1 ½ A Thread ISO 228 steel - - GR2 G 1 ½ A Thread ISO 228 316Ti - - GR4 G 1 ½ A Thread ISO 228 Alloy B - - GR5 G 1 ½ A Thread ISO 228 Alloy C - - GR6 G 1 ½ A Thread ISO 228 Monel - - KF1 20 K 50 A RF Flange JIS B2210 steel 2,6 kg KF2 20 K 50 A RF Flange JIS B2210 316Ti 2,6 kg KF4 20 K 50 A RF Flange JIS B2210 Alloy B >316Ti 2,8 kg KF5 20 K 50 A RF Flange JIS B2210 Alloy C >316Ti 2,8 kg KF6 20 K 50 A RF Flange JIS B2210 Monel >316Ti 2,8 kg ME2 DN 50 PN 40 DIN 11851 304 0,5 kg Hygienic connection NG2 DN 50 PN 40 N Flange DIN 2512 316Ti 3,0 kg NM2 DN 80 PN 16 N Flange DIN 2512 316Ti 4,5 kg NQ2 DN 100 PN 16 N Flange DIN 2512 316Ti 5,4 kg TE2 DN 40-51 (2") 304 0,5 kg Tri-Clamp connection YY9 Special version 40 Inactive length L3, material A Inactive section not selected - - C... mm (100 mm... 4000 mm) 316Ti 0,2 kg/100 mm D... mm (100 mm... 4000 mm) Alloy B 0,2 kg/100 mm E... mm (100 mm... 4000 mm) Alloy C 0,2 kg/100 mm F... mm (100 mm... 4000 mm) Monel 0,2 kg/100 mm Y Special version 50 Active guard build-up compensation 1 Active guard not selected - - 3 150 mm 316Ti 0,5 kg 4 150 mm Alloy B 0,6 kg 5 150 mm Alloy C 0,6 kg 6 150 mm Monel 0,6 kg 9 Special version 60 Probe length L, material A... mm (100 mm... 6000 mm) B... mm (100 mm... 6000 mm) C... mm (100 mm... 6000 mm) D... mm (100 mm... 6000 mm) E... mm (100 mm... 6000 mm) H... mm (100 mm... 6000 mm) with ground tube J... mm (100 mm... 6000 mm) with ground tube K... mm (100 mm... 6000 mm) with ground tube steel 316Ti Alloy B Alloy C Monel steel 304 316Ti Alloy B 0,1 kg/100 mm 0,1 kg/100 mm 0,1 kg/100 mm 0,1 kg/100 mm 0,1 kg/100 mm 0,3 kg/100 mm 0,3 kg/100 mm 0,3 kg/100 mm 14 Endress+Hauser

60 Probe length L, material L... mm (100 mm... 6000 mm) with ground tube M... mm (100 mm... 6000 mm) with ground tube Y Special version 1 350 mm 2 500 mm 3 350 mm 4 500 mm Alloy C Monel steel steel 316Ti 316Ti 0,3 kg/100 mm 0,3 kg/100 mm 70 Partial 1... mm (100 mm... 4000 mm) PTFE insulated - - 2... mm (100 mm... 4000 mm) PE insulated - - 3... mm (100 mm... 4000 mm) PFA insulated - - 4 100 mm PTFE insulated (standard) - - 9 Special version 80 Option 1 Basic version - - 2 Temperature spacer 0,5 kg 3 Gas-tight probe seal 0,5 kg 9 Special version 90 Housing, Cable Entry C Aluminium E-Housing NPT ½" IP66 - - D Aluminium E-Housing G ½ A IP66 - - E Aluminium E-Housing M 20x1,5 IP66 - - F Aluminium E-Housing HNA 24x1,5 IP66 - - J 316Ti E-Housing HNA 24x1,5 IP66 0,7 kg L Polyester E-Housing NPT ½" IP66 - - M Polyester E-Housing G ½ A IP66 - - O Polyester E-Housing M 20x1,5 IP66 - - P Polyester E-Housing HNA 24x1,5 IP66 - - T Ctd. aluminium E-Housing NPT ½" IP66 - - U Ctd. aluminium E-Housing G ½ A IP66 - - V Ctd. aluminium E-Housing M 20x1,5 IP66 - - W Ctd. aluminium E-Housing HNA 24x1,5 IP66 - - 9 Special version DC 16 - Complete product designation! Note! Please state lengths for the probe when ordering. See also dimensioned drawings on Pages 6 to 8. Screening L3 Partial Total length of probe L from the sealing surface of the process connection Endress+Hauser 15

Accessories see Technical Information TI 229F: "Probe accessories" Slip-on sheet for increasing impedance range Protective cover for the probe housing Supplementary Documentation Technical Information (TI) Electronic Inserts EC 11 Z, EC 72 Z TI 270F/00/en Electronic Insert EC 16 Z TI 170F/00/en Electronic Insert EC 17 Z TI 268F/00/en Electronic Inserts EC 37 Z, EC 47 Z TI 271F/00/en Electronic Insert EC 61 Z TI 267F/00/en Probe accessories TI 229F/00/en Separate housing for electronic insert TI 228F/00/en Transmitters for limit detection and continuous level measurement on request Endress+Hauser GmbH+Co. Instruments International P.O. Box 2222 D-79574 Weil am Rhein Germany Tel. (07621) 975-02 Tx 773926 Fax (07621) 975 345 e-mail: info@ii.endress.com Internet: http://www.endress.com 11.01 TI 096F/00/en/04.03 017186-1000 SL/FM + SGML6.0 ProMoDo 017186-1000