LifeStar Ambulance Inverter

Similar documents
CUL INVERTER/CHARGER OWNER'S MANUAL

BRAVO Inverter/Battery Charger. Table of Contents

VLT SERIES. True Sine Wave AC Power Inverter. Owner s Manual. Owner s Manual D Rev.B

IQC IQC IQC

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

Battery Equalizer. Table of Contents Introduction. 2. Specifications.. 3. Theory of Operation Typical Applications... 5

Go Power! Manual. GP-SW1500 Inverter. Table of Contents. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4

GSL Electronics Modified Sine Wave Power Inverters

Pure Sine Wave Inverter GP-HS1500. Owner s Manual

Pure Sine Wave Inverter Charger

Section 1 Introduction... 1

WF-5110R True Sine Wave Inverter

WF-5110R True Sine Wave Inverter

DC TO AC POWER INVERTER

PureSine 150/300 Pure Sine Wave Inverter User s Manual

IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase.

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

Table of Contents 文管中心 發行章

Power InverterTM Watt. Continuous. User's Manual. WAGAN Corp. Limited Warranty Registration Form. Item no

DC to AC Power Inverters

DC to AC Power Inverters

User Manual 1KVA-5KVA INVERTER / CHARGER

User Manual 5KVA/5KW INVERTER / CHARGER. Version: 1.3

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual

This file was converted to PDF format. If you are interested in a Microsoft PowerPoint formatted file send a request to:

User manual. Solar Hybrid 1-5KVA. Uninterruptible Power Supply / Charger

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

User s Manual. Automatic Switch-Mode Battery Charger

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

SCC-MPPT Solar Charge Controller

V 2.0 DC TO AC POWER INVERTER PWRINV500012W PWRINV500024W PWRINV500036W PWRINV500048W. Instruction Manual

AC CONVERTER / BATTERY CHARGER

Solar Hybrid Inverter SP Efecto Series

SCC-MPPT Solar Charge Controller

S150,S300 Series Pure Sine Wave Inverter User s Manual

User Manual 1KVA-5KVA INVERTER / CHARGER

MPPT Controller PVTS Series User Manual. User Manual. 800W-4000W Hybrid solar inverter. Version: 1.4

MIL-24/2600Q MIL-24/3200DQ

Pure Sine Wave Inverter User Manual

ADI-125/750 ADI-125/1500 ADI-125/2500

1KVA/ 2KVA/ 3KVA/ 4KVA/ 5KVA MS, LV MPPT INVERTER / CHARGER. User Manual. Version: 2.3

User Manual 1KVA-5KVA (PF1) INVERTER / CHARGER. Version: 1.0

WF-5100 Series True Sine Wave Inverters

The Power of Reliability INSTRUCTION MANUAL

Solar Charge Controller

User Manual SOLARMAX 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

SCC-MPPT Solar Charge Controller

Solar Hybrid Inverter SP Efecto Series

User Manual 4KVA/ 5KVA INVERTER / CHARGER. With MPPT Controller

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

BZ Products Inc. U.S.A.

OWNERS MANUAL JANUARY 2007 ISO

User Manual 1KVA-5KVA INVERTER / CHARGER. Version: 2.1

USER MANUAL FOR 2000 WATTS POWER INVERTER USER S MANUAL--Read before operating this equipment

Solar inverter with MPPT AX II - M series: 4 / 5 kva, AX II - P series: 3 kva. With integrated star point grounding* according to VDE AR-E 2510-

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER

O W N E R ' S M A N U A L

User Manual 1.5KVA-3KVA INVERTER / CHARGER. Version: 1.1

OWNERS MANUAL JANUARY 2007 ISO

POWER INVERTER 700 WATT / 1800 WATT PEAK

SBC V In-Car Charger Dual Input (Solar MPPT & DC)

SOLAR INVERTER/CHARGER SOLAR INVERTER/CHARGER MPPT 2KVA- 3KVA. Appliances. Airconditioning Fridge. Washing machine

Solar Hybrid Inverter SP Brilliant Series

Installation and Operation Guide. Tundra HD 2500 Power Inverter. for the. Webasto BlueCool Truck System

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual

StartSentry. UCS-80Kj and UCS-80KjC. Ultra Capacitor. Table of Contents

The Traveler Series: Wanderer

User Manual 3KW/5KW INVERTER / CHARGER. Version: 1.0

1250W 12VDC PowerVerter Ambulance/EMS Inverter/Charger with 2 Hospital Grade Outlets

Installation Instructions & Users Manual

Special Specification 6058 Battery Back-Up System for Signal Cabinets

SP6. Automatic Battery Charger. Model

PUMP PLUS 2000 PLC MODEL #: PP AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

BBC-3140 USER MANUAL DC-DC CHARGER / BATTERY EQUALIZER / VOLTAGE REDUCER

Duo Battery Charge Controller

XP600/1100/2000 INSTALLATION AND OPERATION MANUAL

User Manual 1.5KVA-3KVA INVERTER / CHARGER

1200+ WITH LVD (LOW VOLTAGE DISCONNECT) USER GUIDE

Idle Free Systems, Inc. Reference Guide System Component Information

THE DLS SERIES BATTERY CHARGING POWER CONVERSION

according to VDE AR-E Manual V 3.1

HPP1 MK5 Owner s Manual

Freedom Owner's Manual. Xantrex Freedom 458 Series Inverter/Charger

SBC / 2140 / Stage Battery Charger User Manual

Power Distribution System User s Manual. Model: PDS-100

INSTRUCTION MANUAL CAUTION

DURABLE DEPENDABLE PROVEN. IOTA Engineering tel:

General safety and installation information.

Compact Sine Inverter

HPP1 MK6-15A/20A R00 Owners Manual

Pure Sine Wave Power Inverter SSW A SSW A SSW A SSW A SSW A

OWNER S MANUAL POWER INVERTER

7 Stage Automatic Smart Battery Charger (FOR CHARGING 12V / 24V AGM, GEL,SLA AND WET BATTERIES) USER MANUAL

BC12M248 7 Stage Automatic Smart Battery Charger, Desulfator & Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL

STEP-BY-STEP INSTALLATION GUIDE

DC TO AC POWER INVERTER PWRIC150012W INSTRUCTION MANUAL

CALTRAP INSTALLATION AND OPERATIONS MANUAL

AeroVironment Universal Solar Pump Controllers

Transcription:

LifeStar Ambulance Inverter Model 20-1050CUL-DC 20-1000TUL-DC LifeStar - 1 -

Table of Contents Table of Contents... 2 Section 1 : General Installation Diagram... 3 Section 2 : Introduction... 4 Section 3. Functionality... 4 Inverter... 4 Battery Charger... 5 DC Power Output... 5 Section 4: Specifications... 6 Section 5: Installing the 20-1050CUL-DC... 7 Unpacking the Inverter... 7 Installing the Inverter... 7 Inverter Lamp Description... 8 Section 6: Installing the Inverter and Charger Remote Status Display Panels... 9 Section 7: Operating the 20-1050CUL-DC Inverter/Charger... 10 Section 8: Troubleshooting the 20-1050CUL-DC... 11 LifeStar - 2 -

Section 1 : General Installation Diagram Interior Mounted Display Exterior Mounted Display LifeStar 12 VOLT DC POWER INVERTER BATTERY CHARGER/CONDITIONER AC OUTPUT INV/CHG AUTOMATIC TRANSFER SWITCH 12 0 V A C 6 0H z POWER INVERTER CHARGE INDICATOR AC ON/ ON Fault Fault Maint. Charge Standby Experience Power... Experience Vanner. ON AC ON/ OF F F L OOD 55A ON ON DC POWER High Charge ON GEL 15A OFF OF F Shore Power Input Ignition Interlock Switch Vehicle Ignition Switch, or equal +12V Remote Switch SCALE: NONE REA/ECO NO.: XXXX THIS DRAWING AND ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF VANNER INC. AND MAY NOT BE COPIED, REPRODUCED OR DIVULGED TO UNAUTHORIZED PERSONS WITHOUT THE EXPRESS WRITTEN CONSENT OF VANNER INC. IT IS PROVIDED SOLELY FOR THE CONVENIENCE OF THE USER AND SHALL BE RETURNED UPON REQUEST. REVISIONS REV DESCRIPTION DATE ECO Interior Mounted DC Service Lamp, ETC Ground Remote ON/OFF Switch ON OFF TOL. UNLESS OTHERWISE NOTED.x ±.025.xx ±.015.xxx ±.005 DRN\DATE CHK\DATE MEO XXX 7-22-08 XX/XX/XX INCORPORATED HILLIARD, OHIO USA TITLE: 20-1050CUL-DC Wiring Diagram DRAWING/ SHEET REV PART NO. OF 1 1 A INVERTER BATTERY LOW OVER TEMP OVER LOAD BULK / ABSORPTION READY/MAINT OFF/RESET CHARGER 1 2 3 1 2 3 4 5 REMOTE STEADY=INVERTER ON BLINK=STANDBY/LOAD DEMAND E 10 4 DESIGNED IN ACCORDANCE WITH POWER INV ERT ER G SA F EDE RA L S PE CIF IC AT ION EM ERGE NCY/ LAND VEHI CLE K KK - A- 1822F 5 8 6 LI S T E D 6 8 U 8 R 1 - LOAD DEMAND 2 - BATTERY TYPE 3 - CHARGE RATE 4 - IGNITION 1. IGNITION 5 - REMOTE SW 2. REMOTE SW 3. +12v DC POWER ON 12v OFF Fuse 150A LifeStar - 3 -

Section 2 : Introduction Thank you for purchasing a Vanner DC Power Inverter for your emergency vehicle. We are confident you will be satisfied with its performance. Vanner products are designed and manufactured by skilled professionals using the highest standards in workmanship, guaranteeing excellent performance and reliability for your emergency vehicle. With minimum maintenance and care, you can expect years of trouble-free service from your Vanner product. The 20-1050CUL-DC is a 12 VDC to 120 VAC inverter with a built-in battery charger/conditioner, transfer relay and KKK Spec 12V Portable Equipment Charging Circuit. This unit is equipped with an AC line cord for connecting AC input power (shore/utility power) and a receptacle with a Ground Fault Circuit Interrupter (GFCI) for AC output. This enables you to plug AC loads directly into the inverter. The DC cables have quick connectors to facilitate installation and pre-wiring of emergency vehicles. The 12V Portable Equipment Charging Circuit has a spring clamp for ease of installation. The transfer relay is powered by +12Vdc, the unit must be connected to the DC source for the transfer relay to work. The 20-1000TUL-DC is a 12 VDC to 120 VAC inverter with transfer relay and KKK Spec 12V Portable Equipment Charging Circuit. This unit is equipped with an AC line cord for connecting AC input power (shore/utility power) and a receptacle with a Ground Fault Circuit Interrupter (GFCI) for AC output. This enables you to plug AC loads directly into the inverter. The DC cables have quick connectors to facilitate installation and pre-wiring of emergency vehicles. The 12V Portable Equipment Charging Circuit has a spring clamp for ease of installation. The transfer relay is powered by 120VAC, the transfer relay will engage without the unit being connected to the DC source. This manual is written around the 20-1050CUL-DC, all sections of this manual that refer to the Charger section of the unit does not apply to the 20-1000TUL-DC. Section 3. Functionality WARNING : Battery input cables must be connected to the battery with proper polarity to avoid damaging the inverter. NOTE : If the battery is fully charged at the time AC input is applied, the unit will go directly into Ready/ Maintenance mode. Inverter The 20-1050CUL-DC converts battery power to 1050 Watts of 120 VAC modified sine wave power to operate vital emergency vehicle equipment. The unit is easily connected to the positive and negative posts of a battery system with appropriate fusing, and when turned on, produces 120 VAC True RMS voltage. The inverter also has an energy-saving feature called Load Demand. With this feature, the inverter output is pulsed, significantly reducing the current draw from the battery until a demand is made on its output. Continuous output of 120 VAC resumes when a load greater than 5 Watts is applied. The load demand feature can be disabled with the Setup Switch on the front panel. A built-in transfer relay switches the AC output receptacle from the inverter to the AC input when the unit senses AC input from the shore/utility power. LifeStar - 4 -

Battery Charger The 20-1050CUL-DC Battery Charger's superior design incorporates a multi-stage charger. This design enables the unit to automatically charge batteries, maintaining the battery's integrity and reducing the likelihood of premature failure. * Bulk Absorption Charge Mode While in the Bulk Charge mode, the unit continuously charges at a constant current of 55 Amps (high setting) this is the factory setting, or 15.0 Amps (low setting) The unit will charge until battery voltage reaches 14.2 VDC for flooded battery setting, or 14.1 VDC for gel battery setting. The unit then supplies a fixed voltage for one hour. * Ready/Maintenance Mode The charger automatically enters the Ready/Maintenance mode, maintaining the battery s proper voltage of 13.2 VDC for flooded battery setting, or 13.6 VDC for gel battery setting. This Ready/Maintenance mode is designed to eliminate gassing (overcharging), helping to extend the life of the battery. A Setup Switch is located on the front panel for selecting the type of battery (Flooded Lead Acid or Gel Lead Acid), charger output current (High/Low), and Load Demand (On/Off). DC Power Output The 20-1050CUL-DC DC Power Output complies with KKK section 3.7.7.2 for PORTABLE EQUIPMENT CHARGING CIRCUIT. Which states A circuit shall be furnished for charging all portable battery powered devices, i.e. suction units, hand lights, portable radios, etc. This circuit shall prevent discharge of chassis batteries by only permitting the charging of portable devices when the vehicle is either running or the optional battery conditioner is connected to shore power. Circuit breaker protection shall be provided and shall have a minimum 10 amp capacity. An additional tagged, identified lead shall be furnished in both the cab and module for connection of additional (future) portable equipment that requires recharging. DC Power (battery power) is available while +12V Remote Switch Terminal is energized and while the 20-1050CUL-DC is in battery charger mode. DC output is protected by a 20A circuit breaker label DC Power LifeStar - 5 -

Section 4: Specifications Inverter 20-1050CUL-DC 20-1000TUL-DC Output at 120 VAC RMS (Continuous Power Rating) 1050 Watts Surge Capacity at 120 VAC (3 sec) 2100 Watts Input Voltage, VDC (Deep Cycle Battery Recommended) 12 VDC, Nominal 10.5 VDC min, 16.0 VDC max. AC Output Voltage 120 VAC ± 5% DC Current Draw (Battery) OFF 0.017 Amps Typical In Load Demand 0.09 Amps Typical Full ON at No AC Load 0.7 Amps Typical Full On with Load Approx. AC Load Watts 10 Frequency 60 Hz ± 0.2% Output Wave Form Modified Sine Wave Battery Charger Charging Capacity (note DC Source section below) 55 Amps (High) 15 Amps (Low) N/A Input Voltage 120 VAC ± 10% N/A Input Current 12.0 Amps N/A Bulk Voltage 14.2 VDC (flooded), 14.1 VDC (gel) N/A Float Voltage 13.2 VDC (flooded), 13.6 VDC (gel) N/A Output Current, GFCI Outlet Output Voltage Output Current AC Input Termination AC Output Termination Ambient Temperature Cooling Air Chassis Dimensions Weight Bypass Transfer DC Source Other Specifications 12 Amps Battery Voltage 20.0 Amps Max. (Current must be subtracted from Charging Capacity above) 3ft. Line Cord Duplex GFCI Receptacle -20 to +110 F, -29 to +43.4 C Fan Cooled Aluminum 11.57 W x 5.94 H x 11.04 D 22 LBS LifeStar - 6 -

Section 5: Installing the 20-1050CUL-DC Unpacking the Inverter Inspect the shipping container and equipment for loose or damaged parts. If any damage is found, immediately notify the freight carrier. Installing the Inverter 1. Verify the inverter ON OFF/Reset switch is in the OFF position (The button should NOT be pushed in.) Make sure power to the vehicle wiring harness is disconnected. 2. Select a location for the unit. An ideal installation location has the following characteristics: Close to the battery (not in the same enclosure) Protected from the weather Well ventilated Air enters by the fan at the rear of the unit, and exits through the sides of the unit. For maximum unit performance, avoid recirculating the same hot air through the unit. 3. Route DC input cables. Route the negative and positive DC input cables from the inverter (through the quick connector) to the battery. If required, protect cables where they contact hard, sharp edges. DC Cable Length Size (AWG) Maximum Distance (FT) 2 AWG 12ft 1/0 20ft 4. Install inline fuse. Install an inline fuse in the red, positive DC input cable between the battery and inverter, within 18 in. of the battery or DC wiring bus system. Vanner recommends using Bussmann ANN-150 Fuse and #4164 Fuse Holder (Vanner P/N: 014838 Fuse and 03637 Holder) or Feraz-Shawmut CNN-150 Fuse and #4164 Fuse Holder. 5. Connect bonding lug. Use an 8AWG or larger copper conductor to connect the chassis bonding lug to the vehicle chassis. 6. Connect the inverter to the battery. Connect the black, negative DC input cable from the quick connector to the battery negative (-) terminal. This battery negative terminal is usually where the battery negative connects to the engine block or frame. Connect the red, positive DC input cable from the quick connector to the in/line fuse near the battery positive (+) terminal. This battery terminal is usually connected to the DC electrical system at the battery side of the Battery Disconnect Switch. 7. Connect DC Power Source terminal to DC loads Connect the output from the DC Power terminal on the front panel of the Inverter to equipment locations on the vehicle, 20Adc max. Max wire size is 12AWG, use the supplied Vanner screwdriver for this terminal. LifeStar - 7 -

8. Select Load Demand option. Select Load Demand option if desired, using the proper switch position on the front panel Setup Switch. With Load demand ON, the inverter conserves battery energy and operates only when a load greater than 5 Watts is applied. (Factory setting is OFF). 9. Select battery type. The charger is capable of charging both gel and flooded lead acid batteries. Select the battery type using the Setup Switch on the front panel. (Factory setting is Flooded). 10. Select the charging rate. (20-1050CUL-DC only) In the high position, the output capability is 55 Amps. In the low position, it is 15 Amps. Vanner recommends the high position for all installations. The low charge rate can be used if there are NO additional DC loads on the vehicle. (Factory setting is 55A) 11. Connect the AC loads. Connect the AC loads to the inverter GFCI receptacle. Any time AC power is applied to the AC input (shore/utility power), it will pass through this GFCI receptacle. 12. Verify installation. Verify all connections are tight and secure. Inverter Lamp Description Inverter Light Action Description Steady Green Light Inverter in On and Operating. Single Blink Green Light Inverter circuit is in Stand-by, Shore power is On and supplying AC power to the AC loads. The Inverter will turn On and supply the load if shore power is lost. Double Blink Green Light Inverter circuit is in load Demand. Shore power is Off. The inverter is waiting for a load greater than 5 watts. Battery Low Light Action Description Solid Red Inverter is On and the battery is almost too low to operate the inverter. Blinking Red The inverter is Off. The battery voltage dropped below 10.5 volts DC and the inverter shut itself Off. The inverter On/Off switch must be cycled to reset the unit. Overtemp Light Action Description Solid Red The unit is Off. The unit has turned itself Off because it is too hot. This can be caused by operating an AC load which is too large for the inverter, or lack of ventilation. When the unit cools the inverter will start operating again. Overload Light Action Description Blinking Red The inverter is On but overloaded. Reduce the AC load quickly or the inverter will shut off due to the overload condition. Solid Red The inverter is Off. An overload has occurred and the inverter has shut off to protect itself. Reduce the AC load, the inverter On/Off switch must be cycled to reset the unit. Charger Bulk Absorption Light Action Description Charger Ready/Maint. Blinking Yellow Light Action Solid Green The charger is operating. The batteries were low and in need of a charge. The charger is in the process of charging the batteries to the bulk voltage. The charging current is limited based on the position of the Charger High/Low switch. Description The charger is operating. The batteries are near full charge and the charger is in the maintenance mode. In this stage, the charger is holding the batteries at the float voltage. The charging current is limited based on the position of the Charger High/Low switch. LifeStar - 8 -

Section 6: Installing the Inverter and Charger Remote Status Display Panels Ø 0.110 (#35 Drill Bit) Hole (2 PLCS) Ø 1.875 (1 7/8) Hole CHARGE INDICATOR 3.015 Fault 2.22 POWER INVERTER AC ON/ Maint. Charge AC ON/ High Charge Fault 1.11 ON Standby Fault 2.360 Remote Mounting Pattern Both the Inverter and Charger Remote Status Display Panels contain a red and green LED indicator, On the charger status panel, a SOLID green light indicates the presence of shore power or that the battery is being maintained at its current level. A FLASHING green light indicates the presence of shore power and the charger is in high charge mode. On the inverter status panel, the SOLID green indicator light signifies the unit is ON, a FLASHING light indicates the unit is in the Standby mode. For both the remotes the red Fault LED indicator shows problems such as over temperature, output overload, or low battery. The panels have a gasket seal which will keep the electronics safe from weather and water spray. Each panel is equipped with a RJ45 connector for easy installation and replacement. The following installation procedure applies to both the inverter and charger panels: Step 1: Select a location for the panel. Identify the desired location for the inverter and/or charger panels. Step 2: Route cable. Carefully route the modular cable from the front of the LifeStar to the remote location. This cable does not need to be shielded but it should be routed away from the AC cables. Step 3: Secure panel to surface. Remove the protective liner from the gasket and mount the panel using the provided #8 screws through the two holes in the panel. LifeStar - 9 -

Section 7: Operating the 20-1050CUL-DC Inverter/Charger Use the following instructions to operate the 20-1050CUL-DC Inverter. Step 1: Install the 20-1050CUL-DC Unit. Completely install the inverter and charger using the instructions provided in Section 2 of this manual. Step 2: Start the vehicle. Step 3: Turn switches on. Turn on the Module Disconnect Switch and the Inverter Remote Switch. Step 4: Verify Power. Apply an AC load, such as a shop light or drill. Verify operation. Step 5: Apply shore power Turn vehicle off, apply shore power to the 20-1050CUL-DC/Ambulance shore line connection. After shore power has been connected one of the Chargers LED s will light or flash. Push the ON-OFF/RESET Inverter Switch to the ON position. The inverter lamp will flash, indicating that the inverter is standing by. Step 6: Observe Transfer Switch. Remove the shore line connection from the emergency vehicle. The unit will automatically switch to Inverter mode and operate the AC load using battery power. When shore power is restored, the unit examines the AC input for five seconds and then switches the loads back to run directly from AC shore power. LifeStar - 10 -

Section 8: Troubleshooting the 20-1050CUL-DC The following are the most common questions heard by Vanner service professionals. If your situation does not apply to the following categories, please contact your local Vanner Inc Distributor. Vanner Inc Customer Service: 1-800-AC-POWER All of the LED s on the front panel blink one at a time, in sequence. It is normal for this to occur if the inverter switch is On when the DC input is connected to the unit. If the DC is already connected and the LED s blink in sequence then the DC input is dipping in voltage. Check for poor connections in the DC wiring, bad battery, or a heavy DC load. ON lamp flashes or does not light steadily after pushing in the ON-OFF/RESET Inverter Switch. Lamp flashes when utility power is present. Lamp flashes in Load Demand Waiting mode. Check/Reset GFCI on the receptacle. Check battery connections if utility power is OFF Check DC fuses if utility power is OFF ON lamp fully illuminates. AC load does not run. Check and reset circuit breaker. Check and reset GFCI Verify AC load and cord is in proper condition. BATTERY LOW lamp illuminates when AC load is applied. Check battery connections. Check battery condition. Recharge battery if voltage is less than 10.5 VDC. Check the vehicle's alternator charging system for proper operation. OVERTEMP lamp illuminates. Something has caused the unit to overheat. Check for obstruction of air flow to the cooling fan or from ventilation holes. Verify AC load is within unit's rated capacity. OVERLOAD lamp illuminates with AC load applied. Verify AC load is within unit's rated surge and continuous capacity. DC fuse blows when connecting DC input cables. Check for reverse polarity: red cable to battery positive (+), black cable to battery negative (-). The unit may be damaged and require repair service. Low battery lamp glows dimly when inverter is off. This is normal. LifeStar - 11 -

Vanner Incorporated 4282 Reynolds Drive Hilliard, Ohio 43026 1-800-AC POWER (1-800-227-6937) Tel: 614-771-2718 Fax: 614-771-4904 www.vanner.com e-mail: pwrsales@vanner.com Part Number Feb 19, 2009 D914588-C Printed in U.S.A. LifeStar - 12 -