A Universal material with outstanding stress retention and resistance to hot water and steam

Similar documents
A Universal Material for Safe and Reliable Sealing

High adaptability and tightness even at low

A High tech Fibre Material ideal for strong alkali media and steam

High adaptability and tightness even at low surface loads

KLINGERSIL C High stress capability due to metal mesh reinforcement. C-4438 KLINGERSIL

A Universal Material for Safe and Reliable Sealing. The global leader in static sealing

KLINGERSILC-4430plus

Right on top A new era in gasket technology

For quite some years the sealing industry in general has been unable to offer an adequate substitute

KLINGERSIL Optimum flange security

KLINGER soft-chem. Benefits: Key features: Certificates and approvals: Properties: Industries:

SIGRAFLEX SELECT. High-Integrity Gasket Made from Natural Graphite with Inner Eyelet. Expanded Graphite. Broad Base. Best Solutions.

Broad Base. Best Solutions.

AFM 34 does not contain any physiologically harmful substances or colour pigments.

Broad Base. Best Solutions.

novatec PREMIUM XP The new generation of fibre-reinforced graphite gaskets.

novapress 850 Extreme adaptability. High fault tolerance. Maximum sealing performance.

novapress Elastomer-bonded fibre gaskets.

acc. to DIN 3535, part 6 FA VP 401 Gaskets with higher thermal resistance

SIGRAFLEX UNIVERSAL. Gasket Sealing Sheet made from Impregnated Graphite with Tanged 316L Stainless Steel Reinforcement. Quality first solutions

Prvi korak pri izbiri tesnil

AFM 37 AFM 37 Technical Data Sheet 337 (previously TDS 270) Material AFM 37 Properties AFM 37 Application Surfaces AFM 37 Approvals DIN- DVGW

novaflon PTFE gaskets for industrial applications.

Expanded Graphite SIGRAFLEX UNIVERSALPRO

novaflon PTFE gaskets for industrial applications.

GASKETS. From compound asbestos free and PTFE sheets, our sealing solutions. INDEX OF GASKETS

Expanded Graphite. TALuft SIGRAFLEX HOCHDRUCKPRO

Pipeline Accessories. Flange Isolation Gaskets 4 pipes

procesna oprema KLINGER tesnila za visoke temperature High Temperature

AFM 38 AFM 38 Technical Data Sheet 338 (previously TDS 278) Material AFM 38 Properties AFM 38 Application Surfaces AFM 38

PSI FLANGE ISOLATION KITS

Garlock Fiber Gasketing BLUE-GARD, IFG, Style 9850, Style 9900

Kovinska tesnila KLINGER

Rubber-steel gaskets. Gasket profiles WG2 WG2P WL-HT KNG. Rubber-steel gaskets

COMPRESSED SHEET GASKET MATERIAL AVAILABLE MATERIALS

KLINGER BALLOSTAR KHE

KLINGER BALLOSTAR KHE 2-piece ball valves DN (1/2" 8")

Garlock Butterfly Valves Technical Catalog Trusted throughout the chemical, petrochemical & many other industries

Installation and Operating Instructions DDM-DS11 DDM-DS11-MS1 DDM-DS11-MS2

Combi-Seal Flange Isolation Gaskets 4 pipes

(EN ) 1) & Gasket Characterization. Reducing Fugitive Emissions. Manfred Schaaf

Provides the perfect seal, protects flanges, valves and pipelines against corrosion whilst improving safety and reducing the risk of fire.

Sealon Adhesive PTFE Gasket Tape. Technical Data Sheet

Fo ge Steel Floating Ball Valves

MIL- DTL D TY 2 - Compressed Sheet with Aramid Fibers/SBR Binder

NOVUS 34. Novus 34 Pressure/Temperature Limits DATA/SPECIFICATION SHEET. Manufacturers and distributors of sealing and jointing materials.

From laboratory into practice

Triple offset butterfly valve meets the stringent requirements of TA-Luft and ISO Advanced environmental protection the ZETRIX way!

PERIL - European Research Project on Characterization of Gaskets for Bolted Flange Connections. H. Kockelmann

SOLID CONSTRUCTION PTFE STEP FACE GASKETS FOR IMPROVED SEALING PERFORMANCE IN MONDI PIPING

Shaft-Hub-Connections

GYLON EPIX The next level in PTFE gasketing

HIGH PERFORMANCE SEALING

Peter Meyer Ball valves Cryogenic

CYLINDRICAL ROLLER BEARING CATALOG TIMKEN SMALL BORE METRIC SEALS CATALOG

Heating oven with mechanical control

TYPE APPROVAL CERTIFICATE

! CAUTION! Damages on the machine possible.

R677. Diaphragm Valve, Plastic

Guarantee for O-rings? Factors influencing their service life.

BUTTERFLY VALVE WITH WELDED ENDS INSTALLATION AND MAINTENANCE MANUAL

Diaphragm valve, Plastic

LCMass Series Mass Flow Sensor

ARI-FABA -ANSI LongLife Stop valve with bellows seal

R690. Diaphragm Valve, Plastic

PSI RUBBER STEEL FLANGE GASKETS

Installation, Operation, and Maintenance Manual

2-port ball valves with flanged connection, PN25

DryLin R Linear Plain Bearings, Fast and Quiet

Heating oven with natural convection

Installation, Operation, and Maintenance Manual

>> KX SAFEFLEX. + higher Cv/Kv Value + low break away torque. Triple-Offset Metal Seated Butterfly Valve. + self centering

TEADIT PLANTS. Teadit International (Kufstein / Austria) Teadit North America (Houston / USA) Teadit Ind. e Com. (Rio de Janeiro / Brazil)

Assembly and operating Instructions RA 60 / FA 60

Expanded and structured

Sizing criteria for cylinders and servocylinders

OG HIGH PERFORMANCE TRIPLE OFFSET BUTTERFLY VALVES SHUT-OFF AND MODULATING SERVICE - SAFE AND ECONOMIC

Diaphragm Valve, Plastic

DryLin R Linear Plain Bearings, Fast and Quiet

Sealing surface pressure and bolt force

Insulating joint IK. Insulating joint IK. RMA Kehl GmbH & Co. KG Oststrasse 17 D Kehl / Germany

DryLin R Linear Plain Bearings, Fast and Quiet

DryLin R Linear Plain Bearings, Fast and Quiet

Type Pressure Transmitter with display. Pressure Transmitter. Technical data. DN15-50 Body material. Stainless steel 316L Actuator material

Operating Guide SBFV (PN16/25) ENGLISH Steel butterfly valve SBFV Page 2. Danfoss VI.IX.A1.02 1

Diaphragm Valve, Metal

ERHARD is a company of. ERHARD ECLI butterfly valve

2-way and 3-way globe valves

GUIDELINES FOR HINGED AND BOLTED MANWAY ASSEMBLY

ARI-ZETRIX Process valve (gear-operated / actuated)

SPIRAL WOUND GASKETS (SWG)

SETTING THE STANDARDS TO BE LEAK FREE

Process Filtration From Pure to Sterile

BS EN ISO 9001 FM Worcester Controls 5 Series BS 5351 Approved Flanged Ball Valves

Fully Welded Ball Valves

Assembly and operating Instructions. Bypass Flow Meter DST

Diaphragm Valve, Metal

2/2-way Angle Seat Valve, manually operated, for media up to +180 C

Diaphragm Valve, Metal

Process Filtration From Pure to Sterile

Transcription:

A Universal material with outstanding stress retention and resistance to hot water and steam (AGA CERTIFIED TO AS4623-8 CLASS III, PRESSURE 2 MPA) KLINGERSIL C-44 Optimum combination of synthetic fibres bonded with NBR. Resistant to water and steam at higher temperatures as well as to oils, gases, salt solutions, fuels, alcohols, moderate organic and inorganic acids, hydrocarbons, lubricants and refrigerants. www.klinger.com.au

Flanged joint integrity The many and varied demands made on gaskets A coon perception is that the suitability and tightness of a gasket for any given application depends upon the maximum temperature and pressure conditions. This is not the case. Maximum temperature and pressure values alone can not define a material s suitability for an application. These limits are dependent upon a multiplicity of factors as shown in the picture below. It is always advisable to consider these factors when selecting a material for a given application. medium pressure temperature flange process control bolt installation A statement about the expected tightness of the flange connection is only possible if a qualified and defined installation of the gasket has been executed. In facilities, for which limited emission requirements acc. to TA-Luft are specified, the guideline VDI 229 for the evaluation of the technical tightness of flange connections has to be considered. Selecting gaskets with pt diagrams The KLINGER pt diagram provides guidelines for determining the suitability of a particular gasket material for a specific application based on the operating temperature and pressure only. Additional stresses such as fluctuating load may significantly affect the suitability of a gasket in the application and must be considered separately. Areas of Application 1 In area one, the gasket material is normally suitable subject to chemical compatibility. 2 In area two, the gasket materials may be suitable but a technical evaluation is recoended. 9 7 p bar p bar i i p bar i - - 3 In area three, do not install the 1 gasket without a technical evalua- tion. Always refer to the chemical resistance of the gasket to the fluid. 9 7-9 7 - - Material thickness 1 3 2 1 C Material thickness 2 3 2 - C 3 2 1 Material thickness 3 C As the maximum operating pressure and load bearing capability are both depending on the gasket thickness, KLINGER provides thickness related pt diagrams.

Flanged joint integrity / Tightness of flange connections KLINGER Hot and Cold Compression Test Method The KLINGER Hot Compression Test was developed by KLINGER as a method to test the load bearing capabilities of gasket materials under hot and cold conditions. In contrast to the BS 731 and DIN 2913 tests, the KLINGER Compression test maintains a constant gasket stress throughout the entire hot compression test. This subjects the gasket to more severe conditions. This test method is specified in DIN 29-2:14 in short-term test. The thickness decrease is measured at an ambient temperature of 23 C after applying the gasket load. This simulates assembly. s up to C are then applied and the additional thickness decrease is measured. This simulates the first start up phase. Thickness decrease % 2 1 1 Stress C The diagram shows the additional thickness decrease at temperature. Thickness decrease % High temperature tightness High temperature tightness is measured by means of the KLIN- GER Hot Compression test under defined constant gasket load and temperature with increasing internal pressures using nitrogen as test fluid. Gasket load 1 Gasket load 2 Gasket load 3 Leak mg/(sm) Leak mg/(sm) Leak mg/(sm) 1 C 1 C 1 C Stabilisation time for each reading is two hours and a new test specimen is used for every gasket load and temperature. The tightness is analysed with a massflow meter. The pressure is controlled by pressure controller. Gas pressure bar Gas pressure bar Gas pressure bar Leak mg/(sm) Leak mg/(sm) Leak mg/(sm)

Tightness of flange connections / Application and Installation instructions Specific requirements on the tightness of flange connections With heightened awareness of safety and environmental issues, reducing leaks from flanged assemblies has become a major priority for industry. It is therefore important for companies who use gaskets to choose the correct material for the job and install and maintain it correctly to ensure optimum performance. In facilities, for which limited emission requirements acc. to TA- Luft or the compliance with tightness classes are required, often with increasing internal pressures high surface pressures have to be applied. For such operating conditions the plant operator has to verify, that the required flange connections are also suitable to bear these demands without mechanical overloading. Only gasket materials with a TA- Luft-certificate may be used. The required tightness and stress analysises acc. to EN 191-1 (or comparable) have to be carried out with specific gasket factors acc. to EN 13. The assembly of the gasket has to be executed solely by qualified assembly personnel (EN 191-4:13). Only the controlled tightening of the bolts assures that the assembly bolt load is within the required narrow tolerances. Tightness of flange connections in operating condition The flange connection will remain tight as long as the surface pressure on the gasket in service is higher than the required minimum surface pressure for a certain tightness class L. The higher the initial surface pressure of the gasket, the safer the required tightness in operating condition can be achieved. The maximum permissible surface pressure of the gasket in operating condition may not be exceeded. The sealing calculation program KLINGER expert contains important information regarding the performance of KLINGER sealing materials. Discontinuous operation If the gasket is to be subjected to non-static loading and stress fluctuations due to temperature and pressure cycling, it is advisable to select a gasket material which is less prone to embrittlement with increasing temperatures (e.g. KLINGER graphite laminate, KLINGER top-chem, KLINGER Quantum). In cyclic loading conditions we recoend a minimum surface stress of. In such cases the gasket thickness should be as thin as technically possible. For safety and functional reasons never re-use gaskets. The following guidelines are designed to ensure the optimum performance of a reliable flange connection. 1. Choosing the gasket There are many factors which must be taken into account when choosing a gasket material for a given application including temperature, pressure and chemical compatibility. Please refer to the information given in our brochure or, for advice to our software program KLINGER expert. If you have any questions regarding the suitability of a material for a given application please contact KLINGER Technical Department. 2. Media Resistance Attention has to be paid on the fact that the media resistance of the gasket material is also given under operating conditions. In general, higher compressed gaskets show a better resistance to media influences than less compressed gaskets. 3. Gasket thickness Gasket width A generally binding rule to determine the required gasket thickness doesn t exist. The gasket chosen should be as thin as technically possible. In most cases, at small and medium nominal diameters, a thickness of 2 is sufficient. To ensure optimum performance a minimum thickness/width ratio of 1/ is required (ideally 1/). 4. Flange connection Ensure all remains of old gasket materials are removed and the flanges are clean, in good condition and parallel.

Application and Installation instructions. Gasket compounds Ensure all gaskets are installed in a dry state, the use of gasket compounds is not recoended as this has a detrimental effect on the stability and load bearing characteristics of the material. In its uncompressed form the gasket can absorb liquid, and this may lead to failure of the gasket in service. To aid gasket removal KLINGER materials are furnished with a non sticking finish. In difficult installation conditions, separating agents such as dry sprays based on molybdenum sulphide or PTFE e.g. KLINGERflon spray, may be used, but only in minimal quantities. Make sure that the solvents and propellants are completely evaporated. 6. Gasket dimensions Ensure gasket dimensions are correct. The gasket should not intrude into the bore of the pipework and should be installed centrally. 7. Bolting Wire brush stud/bolts and nuts (if necessary) to remove any dirt on the threads. Ensure that the nuts can run freely down the thread before use. Apply lubricant to the bolt and to the nut threads as well as to the face of the nut to reduce friction when tightening. We recoend the use of a bolt lubricant which ensures a friction coefficient of about. to.14. 8. Joint assembly It is recoended that the bolts are tightened using a controlled method such as torque or tension, this will lead to greater accuracy and consistency than using conventional methods of tightening. If using a torque wrench, ensure that it is accurately calibrated. For torque settings please refer to the KLINGER expert or contact our Technical Department which will be happy to assist you. Carefully fit the gasket into position taking care not to damage the gasket surface. When torquing, tighten bolts in three stages to the required torque as follows: Finger tighten nuts. Carry out tightening, making at least three complete diagonal tightening sequences i.e. %, % and % of final torque value. Continue with one final pass torquing the bolts/ studs in a clockwise sequence. If certain tightness classes should be achieved in critical plants, the installation of the gasket has to be executed by qualified and competent assembly personnel (acc. to EN 191-4), without exception. 9. Tightness of the flange connection Basically the tightness depends on the applied surface pressure during installation, as well as on the remaining surface pressure in the operating condition. Gaskets installed with high seating stresses exhibit a longer service life than gaskets installed with lower compressive stresses.. Retightening Provided that the above guidelines are followed retightening of the gasket after joint assembly should not be necessary. If retightening is considered necessary, then this should only be performed at ambient temperature before or during the first start-up phase of the pipeline or plant. Retightening of compressed fibre gaskets at higher operating temperatures and longer operating times may lead to a failure of the gasket connection and possible blow out. 11. Low temperature area KLINGER gaskets are also applicable at low temperatures without any problems. The assurance of the required surface pressure in the complete temperature range, is the precondition for the tightness of the flange connection. 12. Re-use For safety and functional reasons never re-use gaskets. KLINGER expert the powerful sealing calculation. The powerful calculation program for the skilled personnel. KLINGER expert s data base con- tains standard flanges, bolt details and a comprehensive catalogue of media to help the user design joints, select materials and calculate installation values. Free download. App for Android and Apple also available.

Gasket factors acc. to EN 13 Maximum permissible surface pressure under operating condition Q Smax acc. to EN 13 The maximum surface pressure in operating condition is the maximum permissible surface pressure the gasket can be loaded at the specified temperatures. To validate the test result of Q Smax, P QR values are provided. An evaluation of the tested gasket regarding unacceptable extrusion in the bore or damage of the gasket is also required. 2 1 1 1 1 23 C C The diagram shows these values for the various temperature ratings. C Q Smax 17 C C C C Creep relaxation factor P QR acc. to EN 13 This factor considers the relaxation influence on the gasket load between the tightening of the bolts and the long-term effect of the service temperature. P QR values for stiffness kn/, gasket thickness 2 Gasket stress P QR at Q Smax Q Smax () 23 C.96.96.99 C.89.93.94 17 C.8.92.91 C.82.91.9 C.79.86.88 C.66.79.86 Secant unloading modulus of the gasket and gasket thickness acc. to EN 13 Secant unloading modulus of the gasket () and gasket thickness () Gasket stress Ambient temperature C 17 C C C C 1 1 1 1 1 12 1768 1 4168 4668 119 13194 74 14966 14964 14279 14791 1.97 1.72 1.716 1.691 1.671 1.61 1.62 1. 1.89 1.77 1.67 1.8 1. 1436 179 272 326 3988 4984 643 6691 6634 727 9764 9764 1.94 1.762 1.736 1.712 1.69 1.671 1.643 1.6 1.1 1.81 1.64 1.48 1. 1983 227 3498 3724 3836 446 288 42 9 2 7772 9439 1.92 1.729 1.712 1.69 1.677 1.6 1.634 1.613 1.91 1.69 1.48 1.31 1.13 1989 3682 2746 396 728 7336 92 7341 84 7974 432 972 1.889 1.712 1.697 1.677 1.69 1.644 1.622 1. 1.78 1.7 1.34 1.18 1.497 2273 3298 241 7 7982 776 1276 11641 228 141 64 927 1.91 1.711 1.696 1.681 1.667 1.6 1.637 1.623 1.8 1.94 1.83 1.69 1.4 69 337 347 4934 741 6117 78 771 8684 9642 9271 9831 1.9 1.728 1.71 1.72 1.688 1.677 1.6 1.64 1.633 1.622 1.613 1.4 1.96

Gasket factors acc. to EN 13 Minimum surface pressure Q min(l) acc. to EN13 (Installation) The minimum surface pressure during installation is the minimum required surface pressure, which has to be applied on the gasket surface during assembly at room temperature. This is to assure that the gasket can adjust to the roughness of the flange surfaces, that internal leakage paths can be tightened and that the required tightness class L for the specified internal pressure will be achieved. Minimum surface pressure Q Smin(L) acc. to EN13 (Operating condition) The minimum surface pressure in service is the minimum required surface pressure, which has to be applied on the gasket surface under operating conditions, i.e. after unloading during service, in order to keep the required tightness class L for the specified internal pressure. 1E+ Minimum stress to seal for tightness class L p = bar Q min(l) at assembly/ Q Smin(L) after off-loading bar Loading curve 1E-1 Unloading curve L Q min(l) Q Smin(L) Qmin Q mg/ Q A = Q A = Q A = Q A = Q A = Smin 1E-2 s x m - -1-2 -3-4 - -6 19 32 46 64 91 16 11 Q A = Stress on the gasket during installation before unloading 1E-7 6 16 1E+1 Minimum stress to seal for tightness class L p = bar Q min(l) at assembly/ Q Smin(L) after off-loading bar Loading curve 1E+ Unloading curve L Q min(l) Q Smin(L) Qmin QSmin mg/ Q A = Q A = Q A = Q A = Q A = 1E-1 s x m - -1-2 -3-4 - 11 18 29 41 4 71 18 Q A = Stress on the gasket during installation before unloading 1E-6 27 9 2 17 Leakage mg/m x s Leakage mg/m x s 1E-3 1E-4 1E- 1E-6 1E-2 1E-3 1E-4 1E- Gasket stress Gasket stress

Technical values Resistant to water and steam at higher temperatures as well as to oils, gases, salt solutions, fuels, alcohols, moderate organic and inorganic acids, hydrocarbons, lubricants and refrigerants. Basis Optimum combination of synthetic fibres bonded with NBR. Typical values for thickness 2. Compressibility ASTM F 36 J Recovery ASTM F 36 J Stress relaxation DIN 2913 Stress relaxation BS 731 KLINGER cold/hot compression, 16 h/17 C, 16 h/ C, 16 h/ C thickness decrease at 23 C thickness decrease at C % 9 % 39 3 31 % 8 % 11 Tightness DIN 29-2 mg/s x m. Dimensions Specific leakrate λ VDI 24 mbar x l/s x m 2.13E- of the standard sheets Sizes: Thickness increase after fluid iersion ASTM F 146 oil IRM 93: h/1 C fuel B: h/23 C % % 3 x, Density g/cm 3 1.8 2, x. Average surface resistance ρ Thicknesses: O Ω 4.1xE13 Average specific volume resistance ρ., 1., 1., D Ω cm 4.xE12 2., 3. ; Average dielectric strength E d kv/ 21.3 Tolerances: Thickness acc. DIN 291-1, length ±, width ±. Average power factor Average dielectric coefficient Thermal conductivity Hz Hz λ tan δ εr W/mK.3 6.7.38 ASME-Code sealing factors Leakage DIN 29 Other thicknesses, sizes and for gasket thickness 1. tightness class.1 mg/s x m y tolerances on request. m 1.1 Surfaces for gasket thickness 2. tightness class.1 mg/s x m y m 1.6 KLINGERSIL gasket materials are for gasket thickness 3. tightness class.1 mg/s x m y generally furnished with surfaces of m 2.2 low adhesion. On request, graphite facings and other surface finishes on one or Classification acc. to BS 731:6 Grade AX both sides are also available. Function and durability The performance and service life of KLINGER gaskets depend in large measure on proper storage and fitting, factors beyond the manufacturer s control. We can, however, vouch for the excellent quality of our products. With this in mind, please also observe our installation instructions. Tests and approvals BAM-tested DIN-DVGW DIN-DVGW W 27 DVGW VP 1 Elastomer-Guideline WRAS approval German Lloyd TA-Luft (Clean air) Fire-Safe acc. to DIN EN ISO 497 Fire-Safe acc. to ISO 19921 AS/NZS Potable Water AGA 4623-8 Class III,2 - Gas Certified according to DIN EN ISO 91:8 Subject to technical alterations. Status: June 17 Klinger Limited Australia 38 McDowell Street,Welshpool,WA66 Phone 1 798 279 in Australia Phone +61 ()8 921 1 Fax +61 ()8 9 9286 e-mail: sales@klinger.com.au http://www.klinger.com.au