YFC. Limit switch. Ex d. 24 operating head types

Similar documents
GRD Electronic earthing system. Ex d. Polyester coating RAL7035. LED indicators

PY, SPY; FSQC, FP; EPC; AP

Junction boxes for control, monitoring and control panel Ex tb

Ex d. S.1 series. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Wide selection of models - IP66 / 67. SSC series

CCAI, CCAIF, CCAIF..H

M-0. M-0... series control, monitoring and signalling devices. Ex e

RLFE. Mounting bracket. Ex de. - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22

EWE. Ex de. Cooling fins

EWE. Cooling fins. Ex de

EJB. Ex d. Stainless steel bolts. - Zone 1, 2, 21, 22 - Group IIB+H2 - Aluminium junction boxes - Choice of 30 sizes - IP 66 / 67.

P, I, A. Command and control stations Ex e

SLEE. - Suitable for high (+55 C) and low (-50 C) temperatures - Elevated degree of protection IP67 - IIB + H2 marking (hydrogen) - Zones 1, 2, 21, 22

FHL. Ex d. Body in aluminium

EJB. Ex d. Stainless steel bolts. - Zone 1, 2, 21, 22 - Group IIB+H2 - Aluminium junction boxes - Choice of 30 sizes - IP 66 / 67.

Limit Switch - Prewired Type Metal Body

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

EXEL-L. Detail of the internal side. Transparent polycarbonate

Limit Switches - Limit Type (PS21L) Metal Body IP66

EVE. Silicon gasket. Ex de

Position Switches Series 8074/2

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Single foot switches PX and PA series

Limit Switches - Limit Type Plastic Body IP65

EXENC-L. - Zone 2, Zone Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components

Limit Switches - Limit Type (PS31L) Plastic Body IP65

Limit Switches - Limit Type Plastic Body IP65

Position Switches Series 8070/2

Position Switches Series 8060/2

Flameproof Enclosures

SFS-UFS Single Foot Switches

Limit Switches - Limit Type (PS42L) Plastic Body IP65

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

Safety switches with separate actuator

Explosion proof electric motor For Fuel dispensing application. Main characteristic

A good connection. International approvals.

Single foot switches - PX and PA series

LK Position Switches TECHNICAL DATASHEET.

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

FL series position switches

Position switches FC series

Switches in conformity with ATEX directive

Switches in conformity with ATEX directive

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals

AVN. - Zone 2, 21, 22 - Lower maintenance costs - Easy to install - Suited to ambient temperatures of up to +55 C. Ex n. Stainless steel clips

Limit Switches - Safety Type Plastic Body IP65 and Metal Body IP66

Control Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations

Safety switches with separate actuator

Solenoid coil for control in potentially explosive areas Type BZ

Unused flameproof threads for cable glands have to be closed with certified plugs.

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx)

Single foot switches PX and PA series

Safety switches for hinged doors

Control and Terminal Box Type A21-**-*****

The Ex-Cell-I series is made for instrumentation with easy access central locking system and hinged cover.

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

New products Ex Equipment 2015

Compact Limit Switches

I Ex-safety switches I

Position switches FD series

Safety switches for hinges

LR-LX-LK-LW Safety Switches with separate actuator

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Safety switches for hinged doors

INSTALLATION AND SERVICE INSTRUCTIONS FOR 2000 SERIES FLAMEPROOF XENON AND FLUORESCENT BEACONS

EX-D ENCLOSURES AND DISTRIBUTIONS

LS Series Limit Switches. Short Form Catalogue AC1300 ABB

Solenoid System. The coil is also in conformity with 94/9/EC ATEX for electrical apparatus of group II, category 3 (Ex na II 3 GD T4 or T5).

International approvals.

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)

Position switches FR series

EX-REPAIR AND MAINTENANCE RECEPTACLES

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Ex e, ia Junction boxes TNCN. Features

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

Terminal Boxes in Stainless Steel SLS**.T

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

CTB. Ex e. Captive screws B.67. Detail of TIG welding of walls. Earth stud with cable anti-rotation bracket

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C...

15 mm Pilot Valve. More technical specifications are reported in the following pages. 1

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

Limit switches Osiswitch Classic For hoisting and materials handling applications, type XCR Complete switches with 1 cable entry

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

Position switches FR series

Comepi Limit Switches

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

Linear Luminaire with LED Series EXLUX 6402/2

Safety rope switches with reset for emergency stop

Compact Sheet-Steel Light Fittings Series 6114/1

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

Metal limit switches are made of zinc alloy and have a degree of protection of IP67 and NEMA Type 4, 4X.

Compact plastic limit switches with positive opening mechanism

High Flow Valve Actuation Range. NAMUR Valves G1/4" & G1/2" Piped Valves G1/4" & G1/2" Banjo Valves G1/8" & G1/4"

Unicode 2 Series Pre-Drilled Control Stations Increased Safety Polyamide, Fiberglass Reinforced Polyester, 316L Stainless Steel, Aluminum

HTSB system System overview

Floodlight LED Series 6525

LED Linear Luminaire Series EXLUX 6402

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Attachments. Explosion-proof actuators. For opening and closing multileaf dampers installed in potentially explosive atmospheres (ATEX) 09/2017 DE/en

Linear luminaire with LED Series EXLUX 6002

Transcription:

Ex d YFC Limit switch 24 operating head types - Group IIC - Zone 1, 2, 21, 22 - Aluminium alloy - Easy installation, wiring and maintenance - Durable and safe over time Fastening system Earth screw RAL735 polyester coating Cable entry Stainless steel screws A.1 ED.218

YFC Series Limit switch Ex d YFC Series explosion-proof limit switches feature an actuator linked mechanically to the contacts. The series includes both position switches and switches for safety applications. They are available in ten basic versions, depending on the type of actuator used, or sixty versions, if snap-action or are considered. Thanks to the combination of various types of actuators, bodies and contacts, YFC limit switches are ideal for a wide range of applications and for seamless system operation. Being corrosion- and vibration-resistant, their mechanical and electrical components are able to withstand the extreme mechanical and thermal stresses they are continuously subjected to. Designed for installation in potentially explosive atmospheres, in the presence of combustible gases (hydrogen and acetylene), vapour, mist and powders, zones 1 and 21, 2 and 22, they are also used in watertight industrial and civil applications. Cortem Group applies a tamper-evident holographic security label to its products, complete with a unique authentication numeric code, to combat the illegal sale of imitations and counterfeits, as well as guarantee the authenticity of its products. Failure to observe international standards creates serious risks for the environment and, above all, for the personnel who work with the systems on a daily basis. Sectors of application: Petroleum refineries Chemical and petrochemical facilities Onshore facilities Offshore facilities Petroleum loading/ unloading pontoons Agribusiness facilities Fuel storage facilities 1% produced by Cortem EMPTY ENCLOSURE CERTIFICATION DATA Classification: Group II Category 2GD Installation: EN 679.14 zone 1 - zone 2 (Gas) zone 21 - zone 22 (Dust) Marking: II 2 GD Ex d IIC T6 Ex d td A21 T85 C IP66/67 Certificate: ATEX SIRA 7 ATEX 1316 IEC Ex IECEx SIR 7.14 For all IEC Ex and TR CU certification data, download the certificate from TR CU B.224 www.cortemgroup.com Standard: Temperature class: Ambient Temp.: Degree of protection: CENELEC EN 679-: 26, EN 679-1: 24, EN 61241-: 26, EN 61241-1: 24 and European Directive 214/34/EU. IEC 679-: 24, IEC 679-1: 23, IEC 61241-: 24, IEC 61241-1: 24 RoHS Directive 22/95/EC. 85 C (T6) -2 C +55 C IP66/67 A QR reader is required to access the information contained in the QRCode. Centre the QR code in the frame of your Smartphone camera. Your Smartphone will open the corresponding address. ATEX Certificate IECEx Certificate Use and maintenance instructions ED.218 A.2

Ex d YFC Series Limit switch MECHANICAL FEATURES Body: Gaskets: Certification label: Screws: Earth screw: Coating: Entry points: Mounting positions: Consistency (measured following a million operations): Minimum control speed: Low copper content aluminium alloy, complete with wall fastening lugs Acid, hydrocarbon and high temperature resistant silicone positioned between the body and the cover Adhesive affixed to external surface Stainless steel Internal and external stainless steel Polyester RAL 735 (Light grey) One entry point ISO M2x All positions.5 mm (at the point of closure).6 m/s slow action.1 m/s snap action : The STANDARD of the aluminium alloy used by Cortem has passed the tests required by standards EN668-2-3 (hot-humid cycles) and EN668-2-11 (salt fog test) ELECTRICAL FEATURES Rated voltage: max. 5 Vac, 25 Vdc Rated frequency: max. 5/6 Hz Rated current: 24 Vac - 5/6 Hz: 1 A 12 Vac - 5/6 Hz: 6 A 23 Vac - 5/6 Hz: 3.1 24 Vac - 5/6 Hz: 3.1 A 4 Vac - 5/6 Hz: 1.8 A 24 Vdc: 2.8 A 125 Vdc:.55 A 25 Vdc:.27 A Connecting cable cross-section:.75... 2.5 mm 2 ACCESSORIES UPON REQUEST / SPECIAL REQUESTS Cable gland A.3 ED.218

YFC Series Limit switch Ex d DIMENSIONAL DRAWING Dimensions in mm Range of operating heads: - plain plunger - roller plunger - roller lever, fixed or adjustable Limit switch body: - aluminium - RAL735 coating - fasten with two M5 screws M5 external earth screw Contacts bracket Contact block: - contacts configuration 1N.O.+1N.C., 2N.O., 2N.C. - positive opening operation - slow or snap action - the two contacts are electrically separated Example of an electrical connection with internal contacts. An NAV2SIB cable gland is used. Limit switch cover ED.218 A.4

Ex d YFC Series Limit switch TERMINOLOGY Positive opening operation A control switch, with one or more break-contact elements, has a positive opening operation when the switch actuator (C) ensures the full opening of the contacts. For the part of travel that separates the contacts, there must be a positive zone with no resilient elements (e.g.: springs) between the moving contacts and the point where the actuator force is applied. The positive opening operation does not deal with N.O. contacts. Control switches with positive opening operation may be provided with snap-action or slow-action contact elements. To use several contacts on the same control switch with positive opening operation, they must be electrically separated from each other; if not, only one contact may be used. Snap action Snap action contacts are characterised by a release position that is distinct from the operating position. The opening (or closure) of snap-action contacts is independent of the switch actuator speed and contributes to regular electric performance, even for slow switch actuator speeds. Slow action have a release position that is the same as the operating position. The switch actuator speed directly conditions the travel speed of contacts. Minimum actuation force / torque The minimum amount of force/torque that is to be applied to the switch actuator to produce a change in contact position. Minimum force/torque to achieve positive opening operation The minimum amount of force/torque that is to be applied to the switch actuator to ensure positive opening operation of the N.C. contact. Po Free position Position of the switch actuator when no external force is exerted on it. Pa Operating position Position of the switch actuator, under the effect of force F1, when the contacts leave their initial free position. Pp Positive opening position Position of the switch actuator from which positive opening operation is ensured. L Max. travel position Maximum acceptable travel position of the switch actuator under the effect of a force F1. Measurements in mm Travel for snap action contacts Travel for non-overlapping Measurements in degrees Pr Release position Position of the switch actuator when the contacts return to their initial free position. C1 Pre-travel Distance between the free position Po and the operating position Pa. Cp Positive opening travel Minimum travel of the switch actuator, from the free position Po, to ensure positive opening operation of the N.C. contacts. C2 Max. travel Distance between the operating position Pa and the max. travel position L. CL Max. travel Distance between the free position Po and the max. travel position L. A.5 For : C3 = C1-1 = pre-travel of contacts C1-2 = pre-travel of contacts C3 Differential travel (C1-C4) Travel difference between Pa and Pr. C4 Release travel Distance between Pr and Po. ED.218

YFC Series Limit switch Ex d Sample order code YFC - E21 Z11 Limit switch with stainless steel lateral plain plunger and snap-action contact (1N.O. + 1N.C.) OPERATING HEAD TYPE CONTACT TYPE CODE SELECTION TABLE OPERATING HEAD E21 Stainless steel lateral plain plunger E22 Stainless steel lateral plunger with Ø12 vertical roller E23 Stainless steel lateral plunger with Ø12 horizontal roller Compliance / (positive opening operation N.C. contacts) EN 541 EN 541 EN 541 Max. control speed [m/s].5.5.5 Minimum actuation force [N] or torque [Nm] 3 / 5 3 / 5 3 / 5 CONTACT TYPE Z11 Snap-action contacts YFC-E21Z11 YFC-E22Z11 YFC-E23Z11 2. 3.2 4.8 6. mm 3.7 5.9 8.8 1.2 mm 3.7 5.9 8.8 1.2 mm X11 Y11 W2 (2N.C.) YFC-E21X11 YFC-E22X11 YFC-E23X11 2.3 3.9 3.2 6. mm 4.6 7.5 6. 1.2 mm 4.6 7.5 YFC-E21Y11 YFC-E22Y11 YFC-E23Y11 2.2 3.6 5.2 6. mm 4.3 6.6 9.5 1.2 mm YFC-E21W2 YFC-E22W2 YFC-E23W2 2.2 3.8 6. mm 4.3 7.2 4.3 6. 1.2 mm 4.3 7.2 6.6 9.5 1.2 mm 1.2 mm 1.2 mm W2 YFC-E21W2 YFC-E22W2 YFC-E23W2 2.1 6. mm 4.1 1.2 mm 4.1 1.2 mm Z2 YFC-E21Z2 YFC-E22Z2 YFC-E23Z2 2. 3.1 4.7 6. mm 3.7 5.7 8.6 1.2 mm 3.7 5.7 8.6 1.2 mm DIMENSIONS (mm) ED.218 A.6

Ex d YFC Series Limit switch CODE SELECTION TABLE OPERATING HEAD E3.. One way lever Ø22 E31: nylon roller E32: stainless steel roller E33: steel bearing E4.. Lever with Ø22 roller E41: nylon roller E42: stainless steel roller E43: steel bearing E44 Lever with Ø5 rubber roller Compliance / (positive opening operation N.C. contacts) EN 541 EN 541 EN 541 Max. control speed [m/s] Minimum actuation force [N] or torque [Nm] 12 / 4.15 /.3.15 /.3 CONTACT TYPE Z11 Snap-action contacts YFC-E3.Z11 YFC-E4.Z11 YFC-E4.Z11 3.1 6.3 1.8 15.5 mm 2 49 2 49 X11 YFC-E3.X11 YFC-E4.X11 YFC-E4.X11 4.5 9. 15.5 mm 22 38 22 38 6.1 Y11 YFC-E3.Y11 YFC-E4.Y11 YFC-E4.Y11 7.2 11.7 15.5 mm 37 53 37 53 4. W2 (2N.C.) YFC-E3.W2 YFC-E4.W2 YFC-E4.W2 4. 9.5 15.5 mm 37 37 W2 YFC-E3.W2 YFC-E22W2 YFC-E4.W2 3.6 15.5 mm 2 2 Z2 YFC-E3.Z2 YFC-E4.Z2 YFC-E4.Z2 3.1 6.1 1.6 15.5 mm 2 32 48 2 32 48 DIMENSIONS (mm) A.7 ED.218

YFC Series Limit switch Ex d CODE SELECTION TABLE OPERATING HEAD E5.. One way lever Ø22 E51: nylon roller E52: stainless steel roller E53: steel bearing E61 Nylon actuator with a stainless steel spring E62 Stainless steel spring actuator Compliance / (positive opening operation N.C. contacts) EN 541 EN 541 EN 541 Max. control speed [m/s] Minimum actuation force [N] or torque [Nm].15 /.3.15 / -.15 / - CONTACT TYPE Z11 Snap-action contacts YFC-E5.Z11 YFC-E61Z11 YFC-E62Z11 2 49 2 2 X11 YFC-E5.X11 YFC-E61X11 YFC-E62X11 22 38 22 22 Y11 YFC-E5.Y11 YFC-E61Y11 YFC-E62Y11 37 53 37 37 W2 (2N.C.) YFC-E3.W2 YFC-E61W2 YFC-E62W2 37 W2 2 YFC-E5.W2 YFC-E61W2 YFC-E62W2 2 2 Z2 YFC-E5.Z2 YFC-E61Z2 YFC-E62Z2 2 32 48 2 32 2 32 DIMENSIONS (mm) ED.218 A.8

Ex d YFC Series Limit switch CODE SELECTION TABLE OPERATING HEAD E7.. Adjustable rod lever E71: stainless steel rod Ø3 E72: nylon rod Ø6 E73: fibreglass rod Ø3 E75: metal rod 3x3 E91 Multi-directional stainless steel spring actuator E99 Pull action with ring Compliance / (positive opening operation N.C. contacts) EN 541 EN 541 EN 541 Max. control speed [m/s] 1.5 Minimum actuation force [N] or torque [Nm].15 /.3.18 / - 25 / - CONTACT TYPE Z11 Snap-action contacts YFC-E7.Z11 YFC-E91Z11 YFC-E99Z11 2 49 9 32 3.2 4.4 5. mm X11 YFC-E7.X11 YFC-E91X11 YFC-E99X11 22 38 12 19 32 2.5 3.2 5. mm Y11 YFC-E7.Y11 YFC-E91Y11 YFC-E99Y11 37 53 2.1 3.4 5. mm 2.1 3.4 5. mm W2 (2N.C.) YFC-E7.W2 YFC-E91W2 YFC-E99W2 37 11 32 3.4 5. W2 2 YFC-E7.W2 YFC-E91W2 YFC-E99W2 1 32 3.6 5. Z2 YFC-E7.Z2 YFC-E91Z2 2 32 48 9 2 32 DIMENSIONS (mm) A.9 ED.218

YFC Series Limit switch Ex d CODE SELECTION TABLE OPERATING HEAD E11 Stainless steel plain plunger E12 Stainless steel ball plunger E13 Stainless steel roller plunger Ø12 Compliance / (positive opening operation N.C. contacts) EN 541 EN 541 EN 541 Max. control speed [m/s].5.5.5 Minimum actuation force or torque 3 / 45 3 / 45 22 / 4 CONTACT TYPE Z11 Snap-action contacts YFC-E11Z11 YFC-E12Z11 YFC-E13Z11 1.8 3. 4.6 6. mm 1.8 3. 4.6 6. mm 3.1 5.3 8.2 mm X11 YFC-E11X11 YFC-E61X11 YFC-E13X11 2.1 3.7 3. 6. mm 2.1 3.7 3. 6. mm 4. 6.9 5.4 mm Y11 YFC-E11Y11 YFC-E61Y11 YFC-E13Y11 2. 3.4 5. 6. mm 2. 3.4 5. 6. mm 3.7 6. 8.9 mm W2 (2N.C.) YFC-E11W2 YFC-E61W2 YFC-E13W2 2. 3.6 6. mm 2. 3.6 6. mm 3.7 6.6 mm W2 1.9 YFC-E11W2 YFC-E61W2 YFC-E13W2 6. mm 1.9 6. mm 3.5 mm Z2 YFC-E11Z2 YFC-E61Z2 YFC-E13Z2 1.8 2.9 4.5 6. mm 1.8 2.9 4.5 6. mm 3.1 5.1 8. mm DIMENSIONS (mm) ED.218 A.1