Field Variable Area Flowmeters BFP Global Purgemaster

Similar documents
SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices. Orifice plate with annular chambers. 4/358 Siemens FI

Model Connections Max. Flow Range (H 2 O) 10A A3220 Horizontal ¼ NPT 100 l/h. 10A3225/55 Vertical ¼ NPT 100 l/h. Vertical 1 NPT Vertical 1 G

Variable Area Flowmeters VA Master TM Indicating Flowrator Meters 10A4500

Variable Area Flowmeters Ori-Flowrator TM Meters

VACUUM PRESSURE PUMPS INSTALLATION CAUTIONS AND INFORMATION READ AND FOLLOW CAREFULLY!

Orifice flowmeter F O N4

Variable Area Flowmeters Armored Purgemeter

Heavy Duty Actuators CONTROLS. Pneumatic Actuators for Quarter-Turn Valves and Dampers Torques to 1,600,000 in. lbs. Double Acting and Spring Return

DATE: May 19, 2000 Service Instruction No. 1443E (Supersedes Service Instruction No. 1443D) Engineering Aspects are FAA Approved

7. Are you upgrading a complete engine from a TCM/ Bendix to a Slick system? If yes, purchase a complete Slick Ignition Upgrade Kit.

SERVICE INSTRUCTION. 652 Oliver Street Williamsport, PA U.S.A. Tel Fax

SERVICE INSTRUCTION. All Certified Lycoming direct drive engines. TIME OF COMPLIANCE: At owner s discretion.

ROTARY SHAFT / OIL SEALS GASKETS LINER RINGS REPAIR KITS BONDED SEALS O RINGS. Automotive Seals VW BARNWELL THE SEAL OF APPROVAL

LYCOMING CYLINDER PRICING

SITRANS P measuring instruments for pressure

CFR Series. Power Inductors OUTLINE FEATURES APPLICATIONS SPECIFICATIONS MITSUMI

MOONEY INTERNATIONAL CORPORATION The Symbol of Performancet MOONEY SPECIAL LETTER Date:

INSTRUCTION MANUAL. includes Parts List FLOW PRODUCTS 10A6100 DESIGN LEVEL B PURGEMASTER FLOWMETERS PN25104

INSTRUMENT PANEL CLUSTERS


Technical Datasheet. Differential Pressure Gauge Diaphragm DG Range. Performance characteristics. Product applications. How can we help you?


THD. Series. Heavy Duty Actuators. Pneumatic Actuators for Quarter-Turn Valves and Dampers CONTROLS. Torques to 1,600,000 In-lbs

Limit Switches and Safety

APPENDIX A Instruction Set. Op Code. T states Flags Main Effects. Instructions

Stars or starlets? Competitor overview switching devices. Only for internal use. sirius IN COMPARISON

MAC VALVES, INC. Rev. T

SSR SSR SSR SSR

SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices Metering pipe with orifice plate and annular chambers 4/369

TECHNICAL INFORMATION LOW FLOW METER. (ethylene propylene rubber) optional. Valve trim (seat and stem) is 316 stainless.

INSTRUCTION MANUAL. VARIABLE AREA FLOWMETERS 10A2235 Rev.5 RATOSIGHT FLOW RATE INDICATORS

King Instrument Company opened its doors in 1983 with one major goal:

Type 520C 85 C Long Life, Inverter Grade, Aluminum High Ripple, Long Life Screw Terminal Type

3RG4 BERO Inductive Proximity Switches

SELECT 3-BURNER PROPANE BARBECUE Assembly Manual

Direct solenoid and solenoid pilot operated valves

Vacuum Automation 2.1. The future depends on good product choices

ABB Automation. Variable Area Dial Flow Indicator Series 10A2227. Series 10A2227 Variable Area Dial Flow Indicator

The Product Range. Technical Data

DATE: February 13, 2019 Service Instruction No. 1037V (Supersedes Service Instruction No. 1037U) Engineering Aspects are FAA Approved

Type 550C 105 C High Ripple, Inverter Grade, Aluminum Ultra-Ripple, Long Life Screw Terminal Type

Process connection. Further designs. Order code. to EN

SIRIUS 3RU2 Thermal Overload Relays

Order No. of the options EMC filter Class A

Direct solenoid and solenoid pilot operated valves

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101

Protection Equipment. 5/2 Introduction

CAT. No. KS-570E. SCS Single Action Push Type. SCD Double Action Type. super. cylinder FUJIKURA RUBBER LTD.

CLOGGING INDICATORS SUMMING-UP DESCRIPTION

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview

Combined pump and gripper Medium

GA 24 Heavy-duty variable area flowmeter

Brooks GT1000 Series. Industrial Glass Tube Variable Area Flowmeters. GT1000 Series. Data Sheet DS-VA-GT1000-eng January, 2008

Basic Hydraulic Features. Basic Mechanical Features

Genuine Metaris Gear Product Technical Catalog. Pumps & Components - MH Series Bearing & Bushing Style

GH General Horizontal, Close Coupled and Frame Mounted Pumps

TM ETRS-TM35FIN-ETRS89 WTG

General. Principles. 3-Trapped Key Switches. 11-Cat. No. Index. Logic. Power. Safety Switches Trapped Key Switches Overview

REV: 000. Super Seca Flash Cure Units

Multiplication Tables of Various Bases

Industrial Controls. 8WN Signaling Columns.

G3 UNIVERSAL GRIP CONFIGURATION GUIDE

Specifications 54 Series Valve

Grade boundaries June 2018 exams. GCSE Reformed (subjects which use the 9 to 1 grade scale)

PISTON STYLE GAUGE. Mid-West Instrument

Partnership that you can trust. LV Switchgear Motor Control Products.

KDM ARMORED FLOW METER & SWITCH

SIRIUS Configuration

Air-oil Systems. Air-oil Systems

part of the EVOX RIFA GROUP

Direct solenoid and solenoid pilot operated valves

Table 1d - FSA for All Returns, Females Tax Year

P-920, Revision 32 Page 2 of 13

The T5220 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

Direct solenoid and solenoid pilot operated valves

Position and Safety Switches

Glass Tube Flowmeter Model GT1000

Direct solenoid and solenoid pilot operated valves

2. COMPACT CYLINDERS series STRONG (RS, RQ)

RCM. Direct Reading Flowmeter. for Liquids or Gases

Air Cylinders. Fine Quality. Precision Engineered. Advanced Design. Excellent Prices S T C. Tel:

S: With magnet. Bore x stroke (basic type) Cushion P: pneumatic adjustable

Guide blocks for ISO/VDMA cylinders

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Item Code Description Quantity 3NA LV HRC FUSE LINK S00 80A 690AC 250DC 30 3NA3832 LV HRC FUSE LINK GL/GG S00 125A 500VAC 250VDC 0

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Milroyal C. PD 3661 Effective 6/2009. MilRoyal C

SPARE CONNECTORS 2008

ACTUATED THERMOMETERS

Direct solenoid and solenoid pilot operated valves

ELITE 2-BURNER PROPANE BARBECUE Assembly Manual

Microbore Hose, Assemblies & accessories

Protection Equipment

EN. 850 Filtrate Pumps. Technical Specification Pages

IEC Power Control SIRIUS. Motor Starter Protectors. Revised 04/20/15. Section Overview... 1/2-1/3. Motor Starter Protectors

Type E-10, E-11 Hazardous Area Explosion-proof Transmitters

DREXELBROOK. Universal IV CM Model 2-Wire, 4-20 ma, Water Cut Monitor. Applications. Durability. Eliminate Routine Maintenance.

Ar-Mite TM Low Flow Armored Flowmeter

Coriolis Flow Solutions for a Global Marketplace

AN RPM to TACH Counts Conversion. 1 Preface. 2 Audience. 3 Overview. 4 References

Transcription:

Data Sheet IT Field Variable Area Flowmeters BFP Global Purgemaster 10A6100 n High Strength Stainless Steel Body - Rigid construction to maintain tube alignment and resistance to pipe strain. n "Snap-in" Tube Construction - Minimizes the downtime needed to clean the meter tube or to change the meter range. n Optimum Variety - Available in 1-1/2, 3, 5, and 10 inch scale lengths and end fitting materials of stainless steel and KYNAR n Internal Back check - Restricts back flow and draining of process fluid when metering tube is removed. (Not available with outlet control valve.) n Control Valve - The optional control valve provides a smooth fine degree of adjustment. n n Versatile Flow Controller - The optional Differential Pressure Regulator is designed to give reliable flow control regardless of changes in upstream pressure. Adjustable Alarms - Single (min. or max.) or Dual (min. & max) alarm sensors are adjustable over the entire meter range. PurgemasterTM Series 10A6100

PURGEMASTER The Purgemaster Purge Meters are low capacity variable area flowmeters for both liquid and gas with an excellent selection of material and scale lengths in a single product family design. They provide optimum flexibility with minimum component proliferation. The meter features a corrosion resistant, high strength stainless steel body, quick, easy snap-in tube construction and a safety tested operator protection shield. The Purgemaster is ideal for such applications as the purging of control lines and instrument enclosures. Their use is easily extended into fluid sampling, liquid specific gravity, and level measurement and similar services. Engineering Specifications Performance: Repeatability: 0.5% of full scale reading. Accuracy: Scale Length 1-1/2 (38 ) 3 (75 m) 5 (127 ) Rangeability: 10 to 1 or greater Operational Limits: ACCURACY STATEMENT ±Percent of Full Scale Standard Accuracy 10% 10% 2%* 10 (250 ) 2% *Except tube number FP-1/8-038-G-6 and FP-1/8-041-G-6 which have ±5% standard accuracy and ±2% optional accuracy. Ambient Temperature Limits: 32 F to 140 F (0ºC to 60 C) Minimum Temperature: 32 F (0 C) Optional Accuracy Minimum Pressure: Full vacuum. If vacuum conditions require a control valve, it should be in the outlet fitting. Maximum Process Temperature and Pressure: Temperature and pressure are interdependent but the listed combination limits must not be exceeded. 4% 4% 1%* 1% End Fitting Mat l 316 316 KYNAR Materials of Construction: Meter Type Adaptor Mat l Tube*: Borosilicate glass Floats*: Refer to Capacity Tables (Table I, II, III, & IV) End Fittings*: 316 stainless steel and KYNAR Tube Adaptor*: 316 stainless steel or KYNAR with stainless end fittings, KYNAR with Kynar end fittings Tube Adaptor Spring*: 316 stainless steel with stainless steel end fittings, Hastelloy "C" with KYNAR end fittings. Float Stop*: 1-1/2 and 3 inch meters 316 stainless steel with stainless steel end fittings, Hastelloy "C" with KYNAR end fittings; 5 and 10 inch meter - Teflon. Tube Rest Gasket: Teflon O-Ring*: Viton when stainless or KYNAR end fittings are specified. Optional: Butyl Rubber, Ethylene Propylene Rubber and Kalrez. Valve Stem*: Stainless steel with stainless fittings; KYNAR tip over stainless steel (non-process wetted) with KYNAR fittings. Internal Back check*: Teflon Body: 304 stainless steel Shield: Acrylic 316 KYNAR KYNAR *Process wetted parts Max. Maximum Fluid Pressure PSIG (kpa) Fluid Operating Temperature ºF(ºC) Temp. ºF(ºC) 250 (120) 200 (93) 150 (65) <100ºF (38ºC) 250 (1724) 250 (1724) 200 (1380) 150ºF 200ºF 250ºF (65ºC) (93ºC) (120ºC) 250 (1724) 225 (1550) 150 (1034) 250 (1724) 200 (1380) 250 (1724) 2

1 Differential Pressure Regulator Body: 316 stainless steel Diaphragm: Viton (with stainless body); Buna-N (optional). Ball Valve: 316 stainless steel Springs: Type 316 stainless steel Max Pressure: 200 psig (1380kPa) at 100 F (38 C) Maximum Differential Pressure: 100 psi (690 kpa) Pipe Connection: 1/4" NPT internal threads Weight (Approximation) Purge Meter Only Scale Length 1-1/2 (38 ) 3 (75 ) 5 (127 ) 10 (250 ) Caution It is important that the process wetted parts materials are compatible with the process fluid. Meter damage, with potential resulting unsafe conditions, can occur if the wrong material is used. For example, VITON O-rings MUST NEVER BE USED FOR AMMONIA SERVICE Warning Operating the meter without the protection shield may result in operator bodily injury. Connections: 1/4 inch NPT. Inlet and outlet fittings are horizontal and face back. Mounting: In-line; wall or front of panel through mounting holes in back of the body; or rear of panel mounting. Scale Length: 1-1/2, 3, 5, and 10 inch. Scales (on tube): As indicated in capacity tables. (Optional metal scale for 5 and 10" rear panel mounting) Purge Meter with Regulator: Add 2-1/2 lb (1.15kg) to weights listed above. 0.45 0.45 0.65 0.80 Note 1: When combined with a 53R2110 Differential Pressure Regulator, the PURGEMASTER can control a flow of liquid or gas that is subject to varying line pressure. However, due to gas compressibility, the true value of mass flow rate of a gas can be measured only if the downstream pressure remains constant. lb 1.0 1.0 1.4 1.8 Kg Alarms Principle of operation The ring sensors with a bistable switching action picks up the relay in the amplifier when the ball float reaches the trigger level and remains in that position, even if the float continues to move towards the alarm zone, thus leaving the trigger level. The relay will drop out as soon as the float crosses the trigger level from the opposite direction, and moves back from the alarm zone into the normal operating range. The actual float position - above or below the trigger level - is precisely indicated. Explosion hazardous operation is feasible, since the ring sensor used is an intrinsically safe switch with intrinsically safe circuit. Due to the relatively short metering tube, type 10A6131 is suitable either as a minimum or a maximum alarm. Models 10A6132 or 10A6133 are recoended if both alarm operations are required. Design Features Sensor height 14, therefore only small coverage of the scale. Integrated clamp device directly to the meter body. No automatically adjustability during operation possible. Alarm Specifications Ring sensor RC-10-14-N for 1/8 inch meter tubes, RC-10-15-N for 1/4 inch meter tubes Bistable Switching Action FM Approved for Class I, Div 1, Groups A, B, C and D; Class II, Div 1, Groups E, F, and G Class III, Div 1 Power supply requirements: 5 to 25 V dc Load Current (current range): 0.01mA, ³.3 ma Repeatability: 0.01 Self Inductance: 100 µh Self Capacitance: 150 nf Ambient temp. limit: -14 F(-26 C) to 158 F(70 C) Cable: 6 1/2 feet (2m) standard (max. 9800 feet (3000 m) possible) Housing: Crastin, black Protective Class: NEMA 4X/IP67 Weight: 150 g (approximate) 3

Switching amplifier Type: Pepperl + Fuchs model (s) KFA 5 (6)-SR2- Ex.W Contact rating: max. 250 VA, max. 2A Supply Voltage: 120 Vac, 240 Vac, ±15%, 45-65 Hz Response Time: Energize approximately 20 ms, De-energized approximately 20 ms Output Type: Single Pole Double Throw (SPDT) Ambient temp. limits: -4 F (-20 C) to + 140 F (60 C) Maximum Wire Size: 2.5 2 (14 AWG) Approvals: IP20; Hazardous field circuit EExia IIC and FM Class I, Div. 1, Groups A to G. The KFA relay amplifiers must be installed in the nonhazardous area when connected to the RC-10 sensors. Housing Material: Makrolon Weight: 150 g. (5.2 oz.) Ordering Information: When ordering, please specify: Complete model number. Materials of construction (end fittings, regulator body). Maximum capacity and unit of flow. Mounting. Type of scale. Accessories. Operating conditions such as: Fluid measured Operating and maximum temperature Operating and maximum pressure Fluid density Fluid viscosity Typical Specifications The purge meter shall have 304 stainless steel body, (KYNAR ) (316 stainless steel) end fittings and (Buna-N) (Viton) O-rings.1 The metering tube shall be easily removable for range change or cleaning without removing the meter from the line or without the use of tools. Meter scale length shall be (1-1/2inches percent only), (3 inches) (5 inches) (10 inches) with (percent) () (direct reading) scale inked directly on the tube. Flow rate shall be (range and units) of (fluid) metered at (temperature and pressure). Maximum temperature and pressure shall be (specify). When integral control valve is required,2 Add: an integral (stainless steel) (KYNAR ) control valve shall be provided. When constant Differential Pressure Regulator is required, Add: A stainless steel constant Differential Pressure Regulator shall be provided to maintain a constant flow rate with varying line pressures. 1 2 Viton O-rings with stainless steel and KYNAR end fitting. Always required with Differential Pressure Regulator Caution Glass tubes are not recoended for either hot or strong alkalies; fluorine, or hydrofluoric acid. Meter tubes should be periodically inspected for signs of wear. Erosion, stress cracks or nicks provide early warning for tube replacement. With certain fluids, the glass may erode unevenly so that wear is not visibly noticeable. If wear is suspected, the tube should be replaced. 4

1-1/2 INCH SCALE METER Scales (On Tube) Standard: Percentage, for all capacities TABLE 1 1-1/2 SCALE LENGTH CAPACITIES (MAXIMUM FLOW RATES) Liquid @ 1.0 sp.gr. & v isc. 1 cps Air @ 1013 mbar Air @ 14.7 psia & 70ºF Metering Tube DP es (1mPas) & 0ºC Float1 Nomenclature of Water CC/MI N Code GPH Code SCC/MIN Code SCFH Code NCC/MIN Code 0.8*# 2AA 0.013*# 2BA 65*# 2CA 0.14*# 2DA 65# 2EA FP-1/16-08-P-1-½ 1.2 1.0*# 2FA 0.016*# 2GA 95*# 2HA 0.20*# 2JA 90*# 2KA FP-1/16-08-P-1-½ SA 1.3 4.0*# 2LA 0.065* # 2MA 180*# 2NA 0.38*# 2PA 170*# 2QA FP-1/16-08-P-1-½ 1.7 7.0# 2AB 0.11# 2BB 420# 2CB 0.90# 2DA 400# 2EA FP-1/16-30-P-1-½ 1.5 13.0 2FB 0.21 2GB 560 2HB 1.20 2JB 550 2KB FP-1/26-30-P-1-½ SA 1.7 22.0 2LB 0.34 2MB 900 2NB 1.90 2PB 850 2QB FP-1/16-30-P-1- ½ 2 38.0 2AC 0.60 2BC 2100 2CC 4.40 2DC 2000 2EC FP-1/8-21-P-1-½ 2 60.0 2FC 0.95 2GC 2600 2HC 5.50 2JC 2600 2KC FP-1/8-21-P-1-½ SA 3.5 120.0 2LC 1.90 2MG 4000 2NC 8.50 2PC 3800 2QC FP-1/8-21-P-1-½ 7.5 190.0 2AD 3 2BD 8000 2CD 17 2DD 8000 2ED FP-5/32-40-P-1-½ 14 450.0 2FD 7 2GD 15000 2HD 32 2FD 15000 2KD FP-5/32-40-P-1- ½ 50 850* 2AE 13.5* 2BE 28000* 2CE 60* 2DE 28000* 2EE FP-1/2-28-P-1-½ 100 1600* 2AF 25* 2BF 48000* 2CF 100* 2DF 45000* 2EF FP-1/4-41-P-1-½ 210 2200*## 2FF 34*## 2GF 7000*## 2HF 150##* 2JF 70000*## 2KF FP-1/4-41-P-1-½ CA 475 * # ## 1 Not available with 53RT 2110 regulator Specify low capacity valves for all stainless steel end fittings Specify standard capacity valves for KYNAR end fittings Key to float nomenclature; = black glass; = stainless steel; SA = sapphire; CA = carbolloy 5

3 Scale Meter Scales (On Tube) Standard: Percentage, for all capacities Optional: See Capacity Table II for available standard direct reading scales. Optional direct reading-other than shown on Table II. TABLE II 3 SCALE LENGTH CAPACITIES (MAXIMUM FLOW RATES) CC/MIN. 4.6 20 29 90 150 240 400 580 1250* 1800* Liquid @ 1.0 sp.gr. Code 3AA 3EA 3AB 3EB 3AC 3AD 3EC 3ED 3AE 3EE GPH 0.07 0.32 0.46 1.4 2.4 3.8 6.5 9.0 20* 29* Code 3CA 3GA 3CB 3GB 3CC 3CD 3GC 3GD 3CE 3GE Maximum Capacities Air @ 14.7 psia & 70ºF SCC/MIN. 380 900 1600 3200 7000 10500 13000 19000 40000* 56000* Code 3BA 3FA 3BB 3FB 3BC 3BD 3FC 3FD 3BE 3FE SCFH 0.8 1.9 3.4 7.0 15 22 27 40 85* 120* Code 3DA 3HA 3DB 3HB 3DC 3DD 3HC 3HD 3DE 3HE SCFM 2* Code 3XE 10 psig @ 70ºF SCFH 2.5 Code 3XA Pressure Drop Across Meter with Valve-Wide Open es kpa H 2O 1.4 0.35 2.2 0.55 2.5 0.62 5.0 1.2 8.3 2.1 18.0 4.5 25.0 6.2 55.0 13.7 222.0 54.7 425.0 105.7 Tube FP-1/8-08-P-3 FP-1/8-08-P-3 FP-1/8-20-P-3 FP-1/8-20-P-3 FP-1/4-15-P-3 FP-1/4-20-P-3 FP-1/4-15-P-3 FP-1/4-20-P-3 FP-1/4-41-G-3 FP-1/4-41-G-3 Float CA 1 * 1 2 These capacities are not available with flow regulator Key float nomenclature; = black glass; = stainless steel; SA = sapphire; CA = carbolloy Specify standard capacity valves for all capacities and all materials 6

5 Scale Meter Scales (On Tube) Standard: Millimeter scales with standard air and water curves Optional: See Capacity Table III for available standard direct reading scales. Optional direct reading - Other than shown on Table III. Percent scale considered as non-standard direct reading. TABLE III 5 SCALE LENGTH CAPACITIES (MAXIMUM FLOW RATES) Maximum Capacities Liquid @ 1.0 sp. gr. Air @ 14.7 psia & 70ºF Tube CC/MIN. Code SCC/MIN. Code 0.65*# 5AJ 55*# 5BJ FP-1/8-038-G-6 1.06*# 5AK 78*# 5BK FP-1/8-041-G-6 2.05*# 5CK 128*# 5DK FP-1/8-041-G-6 3.3*# 5CJ 185*# 5DJ FP-1/8-038-G-6 4.7*# 5EK 250*# 5FK FP-1/8-041-G-6 6.0# 5AA 390# 5BA FP-1/8-08-G-5 10.8# 5CA 540# 5DA FP-1/8-08-G-5 14.0 5AB 720 5BB FP-1/8-12-G-5 22.5 5AC 1080 5BC FP-1/8-16-G-5 35.0 5EC 1450 5FC FP-1/8-16-G-5 43.0 5AD 1950 5BD FP-1/8-25-G-5 61 5CC 2150 5DC FP-1/8-16-G-5 82 5AL 2900 5BL FP-1/8-20-G-5 88 5AE 4100 5BE FP-1/4-10-G-5 110 5CD 3800 5DD FP-1/8-25-G-5 170 5AF 7400 5BF FP-1/4-16-G-5 225 5AM 9600 5BM FP-1/4-20-G-5 300 5AG 12600 5 FP-1/4-25-G-5 420 5CF 14500 5DF FP-1/4-16-G-5 SCFH 550 5CM 39 5DM FP-1/4-20-G-5 570 5AH 49 5BH FP-1/4-40-G-6 720 5EG 50 5FG FP-1/4-25-G-5 1060* 5CG 70* 5DG FP-1/4-25-G-5 1340* 5CH 96* 5DH FP-1/4-40-G-6 2000*## 5EH 135*## 5FH FP-1/4-40-G-6 Float SA SA SA CA CA Π inches of Water 1.2 1.2 1.3 1.6 1.7 1.3 1.5 1.5 1.9 2.2 2.5 3.4 4.0 3.3 4.8 6.7 12.0 18.0 33.0 50 56 71 113 189 385 * # Not available with 53RT 2110 regulator Specify low capacity valves for all stainless steel end fittings. Specify standard capacity valves for KYNAR end fittings. ## Specify high capacity valves for all stainless steel end fittings. Specify standard capacity valves for KYNAR end fittings. 7

10 Scale Meter Scales (On Tube) Standard: Millimeter scales with standard air and water curves Optional: See Capacity Table IV for available standard direct reading scales. Optional direct reading - Other than shown on Table IV. Percent scale considered as non-standard direct reading. TABLE IV 10 SCALE LENGTH CAPACITIES (MAXIMUM FLOW RATES) Maximum Capacities Liquid @ 1.0 sp. gr. Air @ 14.7 psia & 70ºF Tube Float CC/MIN. Code SCC/MIN. Code 6.0# 1AA 365# 1BA FP-1/8-077-G-10 10.4# 1CA 510# 1DA FP-1/8-077-G-10 SA SCFH 16.4 1AB 1.8 1BB FP-1/8-13.3-G-10 21.2 1EA 1.7 1FA FP-1/8-077-G-10 28.0 1CB 2.4 1DB FP-1/8-13.3-G-10 SA 44.0 1EB 3.7 1FB FP-1/8-13.3-G-10 48.5 1AC 4.6 1BC FP-1/8-32-G-10 73.0 1EC 6.0 1FC FP-1/8-32-G-10 SA 91.0 1AD 9.2 1BD FP-1/4-10-G-10 122 1CC 9.3 1DC FP-1/8-32-G-10 184 1GC 13.8 1HC FP-1/8-32-G-10 CA 224 1AE 20 1BE FP-1/4-19-G-10 365 1CD 25 1DD FP-1/4-10-G-10 CA 535 1EE 37.5 1FE FP-1/4-19-G-10 590 1AF 52.2 1BF FP-1/4-40-G-10 800* 1CE 53.5* 1DE FP-1/4-19-G-10 CA 1300* 1CF 92* 1DF FP-1/4-40-G-10 1880*## 1EF 132*## 1FF FP-1/4-40-G-10 CA Π inche s of water 1.5 1.8 1.9 2.2 2.3 3.0 3.4 4.8 2.6 7.9 9.0 11.5 18.4 49 63 75 225 465 * # Not available with 53RT 2110 regulator Specify low capacity valves for all stainless steel end fittings. Specify standard capacity valves for KYNAR end fittings. ## Specify high capacity valves for all stainless steel end fittings. Specify standard capacity valves for KYNAR end fittings. 8

Model Number Designation PURGEMASTER Flowmeter 10A61 Process Connection 1/4" NPT... 3 Specials... Z Meter Tube, Scale Length 3" scale... 1 5" scale... 2 10" scale... 3 1-1/2"scale... 4 Valve Location (Note 1) Without Valve... A Outlet Valve, Std. Capacity... M Inlet Valve, Std. Capacity... N Outlet Valve, Low Capacity... C Inlet Valve, Low Capacity... D Outlet Valve, High Capacity... E Inlet Valve, High Capacity... F Design Level... B Tube Size 1/8"... 1 1/4"... 2 1/16" (Only w/ 1-1/2" and 5" length) (Requires low capacity valve)... 3 5/32" (Only w/1-1/2" length)... 4 Materials of Construction Fittings/O-Rings/Adaptors 316ss/Viton/... B *Kynar/Viton/Kynar (NPT only)... D 316ss/Buna/... E *Kynar/Buna/Kynar (NPT only)... G 316/Viton/Kynar... H 316/Buna/Kynar... J *316/EPR/... L Special... Z *Not available with Regulator Mounting (Meter & Regulator) In-Line (Pipe)... 1 Wall Mount... 2 Rear Panel Mount... 3 Front Panel Mount... 4 Regulator Piping No Regulator... X Stainless Steel... A 9

PURGEMASTER Flowmeter 10A61 A A E _ Alarm Option* (Includes Ring Sensor) (Not available with 1-1/2" size. 1/8 and 1/4" diameter tube only Not Required... 00 Minimum Alarm... 10 Maximum Alarm... 20 Minimum & Maximum Alarm (5 & 10" Tubes Only)... 30 Modified for Alarms without Sensor or Relay... 90 *Must use Metallic Floats,, Ca Connection Accessories Not Required... A ABB Logo Tag... A Language English... E Alarm Relay (Power Requirements) Not Required... X 110 Vac... 3 220 Vac... 4 External Metal Scale (Rear Panel Mount. 5 & 10" Only) Not Required... B Required... C Calibration Standard Accuracy (+10%, 1-1/2 & 3" scale +2%, 5 & 10" scale) Except 1/16-G5 Tubes, 1/8-038-G6 & 1/8-041-G6 are +5%)... 1 Calibrated Accuracy (+4%, 1-1/2 and 3" Scale)... 2 Calibrated Accuracy (+1%, 5 & 10" Scale Except 1/16-G5 tubes, 1/8-038-G6 & 1/8-041-G6 are +2%)... 3 Scales Not Required... X Direct Reading (Standard Scales listed in Spec Sheet)... B Direct Reading (Special Scales)... C Millimeter... D Percent... E Dt/Df... F Standard Ranges 2.5 scfh Air @ 10psig & 70 F (3" Only)... 3XA 2.0 scfm Air @ 14.7psia & 70 F (3" Only)... 3XE 240 cc/min Water (3" Only)... 3AD Other (Supply 3 Digit Code or leave blank for factory sizing)... XXX Notes: 1. Specials, low and high capacity valves are not available in KYNAR. 10

DIMENSIONS NOM Sca le Length 1-1/2 38 3 76 5 127 10 254 A 4-3/4 5-15/16 10-3/8 14-13/16 121 151 264 376 3-23/32 4-15/16 9-3/8 13-13/16 B 94 125 238 351 1-15/32 2-11/16 7-1/8 11-9/16 C 37 68 181 294 3-23/32 8-5/32 12-19/32 D 94 207 320 Note: 1. 2. 3. 4. 5. 6. 7. Dimensions are in inches, unless otherwise specified. Dimensions in parentheses ( ) are in millimeters. All dimensions subject to manufacturing tolerance of ± 1/8 inch (3) unless otherwise specified. Dimensions guaranteed only if this print is certified. To panel mount meter, white background must be removed to gain access to holes in backplate. Use #8 flat head screws. This drawing is third angle projection as shown. Connections are available in 1/4 NPT. NOM Sca le Length 3 76 5 127 10 254 A 6-15/16 10-3/8 14-13/16 151 264 376 B 4-15/16 9-3/8 13-13/16 125 238 351 2-11/16 7-1/8 11-9/16 C 58 181 294 D 3-23/32 8-5/32 12-19/32 94 207 320 Note: 1. 2. 3. 4. 5. 6. 7. Dimensions are in inches, unless otherwise specified. Dimensions in parentheses ( ) are in millimeters. All dimensions subject to manufacturing tolerance of ± 1/8 inch (3) unless otherwise specified. Dimensions guaranteed only if this print is certified. To panel mount meter, white background must be removed to gain access to holes in backplate. Use #8 flat head screws. This drawing is third angle projection as shown. Connections are available in 1/4 NPT. 11

FIGURE 3 WALL MOUNT PURGEMASTER WITH REGULATOR Dwg. No: OD-10-2713 NOM Sca le Length 1-1/ 2 38 3 76 5 127 10 254 7-1/2 8-7/8 13-5/16 17-3/4 A 190 225 338 451 Notes: 1. Dimensons are in inches, unless otherwise specified. 2. Dimensions in parentheses ( ) are in millimeters. 3. All dimensions subject to manufacturing tolerance of + 1/8 inch (3), unless otherwise specified. 4. Dimensions guaranteed only if this print is certified. 5. For outline dimensions of meter, see dwg. no. C-OD-10-2711 & OD-10-2750. 6. Connections are available in 1/4 NPT. FIGURE 4 REAR PANEL MOUNT PURGEMASTER WITH REGULATOR NOM Scale Length A B 1-1/2 38 5-7/8 149 5-7/8±1/4 149±6 3 76 5-7/8 149 5-7/8±1/4 149±6 5 127 10-1/4 260 4-21/32±1/4 118±6 10 254 14-11/16 373 4-21/32±1/4 188±6 Notes: 1. Dimensons are in inches, unless otherwise specified. 2. Dimensions in parentheses ( ) are in millimeters. 3. All dimensions subject to manufacturing tolerance of + 1/8 inch (3), unless otherwise specified. 4. Dimensions guaranteed only if this print is certified. 5. For outline dimensions of meter and panel cut-out, see dwg. no. OD-10-2715. 6. Panel hardware for max 5/16 panel. 7. Connections are available in 1/4 NPT Dwg. No: OD-10-2716 12

FIGURE 5 REAR PANEL MOUNTING OF PURGEMASTER N om Sca le A B C Length 1-1/ 2 38 4-31/32 126 3-23/32 94 4-27/32 123 3 76 6-3/16 157 4-15/16 125 6-1/16 154 5 127 10-5/8 270 9-3/8 238 10-1/2 267 10 254 15-1/16 383 13-13/16 351 14-15/16 379 FIGURE 6 ALARM RING SENSOR 5-3/32 6-5/16 10-3/4 15-3/16 D 129 160 273 386 Notes: 1. Dimensons are in inches, unless otherwise spec ified. 2. Dimensions in parentheses ( ) are in millimeters. 3. All dimensions subject to manufacturing tolerance of + 1/8 inch (3), unless otherwise specified. 4. Dimensions guaranteed only if this print is certified. 5. Dotted line indicates rear of panel clearance requirements. 6. Panel hardware for max 5/16 panel. 7. This drawing is third angle projection as shown. 8. Connections are available in 1/4 NPT. Diameter A () 1/8 10 1/4" 15 FIGURE 7 ALARM, SWITCHING AMPLIFIER 13

NOTES ABB has Sales & Customer Support expertise in over 100 countries worldwide www.abb.com The Companys policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. Printed in USA (10.20.03) ABB 2003 BFP INDUSTRIAL VALLE PERDIDO 61 VALLE DE ARAGON 3ª S ECATEPEC EDO MEX MEXICO Tel: +(55) 5120 0045 Fax: +(55) 5121 4422 ABB Ltd Howard Road, S t. Neots Cambridgeshire PE19 8EU UK Tel: +44 (0)1480 475321 Fax: +44 (0)1480 217948 14