MODEL MX75 3 OVAL GEAR FLOWMETER

Similar documents
MODEL MX12 1/2 OVAL GEAR FLOWMETER

MX06 - MX100 OVAL GEAR FLOWMETER SERIES

OVAL GEAR FLOWMETER ELECTRONIC MODEL 019 / ¾

OVAL GEAR FLOWMETER ELECTRONIC MODEL 006/009 (¼ )

MX06 - MX100 OVAL GEAR FLOWMETER SERIES APPROVED FOR USE IN HAZARDOUS AREAS

OVAL GEAR FLOWMETER MECHANICAL MODEL 075 (3 )

OVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ )

OVAL GEAR FLOWMETER ELECTRONIC MODEL 025 / 1. Type CR for Corrosive Applications

OVAL GEAR FLOWMETER ELECTRONIC MODEL 025 / 1

Operating Instructions for Oval Wheel Flowmeter. Model: DOC

Positive Displacement Flowmeters GM020 series instruction manual

POSITIVE DISPLACEMENT FLOWMETERS

OVAL GEAR FLOWMETER ELECTRONIC MODEL 006/009 (¼ )

POSITIVE DISPLACEMENT FLOWMETERS

OVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ )

Positive Displacement Flowmeters GM020 series instruction manual

Positive Displacement Flowmeters GM007 series instruction manual

POSITIVE DISPLACEMENT FLOWMETER

MX-SERIES OVAL GEAR FLOW METERS

INSTRUCTION MANUAL MN7 series

The experts in fluid technology

The experts in fluid technology

IM012E (ELECTRONIC) POSITIVE DISPLACEMENT FLOWMETER INSTRUCTION MANUAL

The experts in fluid handling

The experts in fluid technology

FPD1000-HP SERIES HIGH PRESSURE Positive Displacement Flowmeters

FPD1001 thru FPD1003, FPD1102 and FPD1103, FPD1201 thru FPD1203 (includes -R Option) Positive Displacement Flowmeters

Positive Displacement Flowmeters GM50 series instruction manual

Positive Displacement Flowmeters GM515 series instruction manual

Installation & Operation Manual

FPD1001B thru FPD1003B, FPD1102B and FPD1103B, FPD1201B thru FPD1203B SERIES LOW FLOW Positive Displacement Flowmeters

POSITIVE DISPLACEMENT FLOW METERS

POSITIVE DISPLACEMENT FLOW METERS

macnaught flow measurement

macnaught flow measurement

Positive displacement flowmeters GM001 series instruction manual

Positive displacement flowmeter for continuous flow measurement

macnaught flow measurement

HG 20F-012E-01 OIL CONTROL GUN

Macnaught Fuel & Oil Flow Meters

Type 2712 (8630) Continuous TopControl System. General data Compatibility Materials of wetted parts Body Rotor Shaft Seal

AHFP-im-issue INSTRUCTION MANUAL HIGH FLOW DIESEL PUMP AHFP70LPM (70LPM) AHFP100LPM (100LPM) AHFP150LPM (150LPM) AHFP70LPM AHFP100LPM AHFP150LPM

OMP Positive Displacement Flowmeters

AMB100L-im-issue INSTRUCTION MANUAL 240V DIESEL MINI BOWSER AMB100L AMB100L

Positive displacement flowmeter

1 in., 1.5 in., and 2 in. electronic high flow meter

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

ADTFM-im -issue INSTRUCTION MANUAL DIGITAL DIESEL METER ADTFM

OM SERIES OVAL GEAR METERS. OM SERIES Oval Gear Meters

OMP POSITIVE DISPLACEMENT FLOWMETERS

Oil Control Handle with Mechanical Meter. Introduction. General Information. Important Information 3575-A 3575-B 3575-C 3575-D

RUN ACCUM. TOTAL STOP BAT LOW HIGH

Positive displacement batch controller

Insertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT

OM004, OM006 & OM008 Oval Gear Meter

Technical Data. Series Oval Flowmeter. Model 9400

M4 Troubleshooting 42

INSTRUCTION MANUAL ELECTRIC DIESEL PUMP KIT

BI-DIRECTIONAL INSERTION FLOW TRANSDUCER

AHFP85L-im -issue INSTRUCTION MANUAL 12V HIGH FLOW DIESEL PUMP KIT AHFP85L-12A

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Operating Instructions for Oval Wheel Flowmeter. Model: DOE

IP80-Series FLOW SENSOR INSTRUCTIONS IP81 IP :2008 ISO CERTIFIED COMPANY IP80-SERIES FLOW SENSOR INSTRUCTIONS

IP800-Series FLOW SENSOR INSTRUCTIONS IP810 IP :2008 ISO CERTIFIED COMPANY IP80-SERIES FLOW SENSOR INSTRUCTIONS

INSERTION flow sensor for continuous flow measurement

I N S T R U C T I O N M A N U A L

IP800-Series FLOW SENSOR INSTRUCTIONS IP810 IP :2008 ISO CERTIFIED COMPANY IP800-SERIES FLOW SENSOR INSTRUCTIONS

TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual

INSTALLATION AND OPERATION

Before first operating the equipment read the whole of these instructions. Safety may be impaired if they are not followed.

I N S T R U C T I O N M A N U A L

BI-DIRECTIONAL INSERTION METER

OVAL GEAR Medium capacity positive displacement Mechanical flowmeters. Model: ½ (15m m)

1100 Series Piston Type Differential Pressure Gauges

TX80-Series FLOW SENSOR INSTRUCTIONS TX81 TX :2008 ISO CERTIFIED COMPANY TX80-SERIES FLOW SENSOR INSTRUCTIONS

OVAL GEAR. Large Capacity Positive Displacement Mechanical Flowmeters. Models: 3 (D-750), 3 (D-1000), 4 (D-1500) & 4" (D-2500)

OVAL GEAR. Medium capacity positive displacement Pulse flowmeters I N S T R U C T I O N M A N U A L

PSF50 Paddle flow switch

SAE J1939 CAN compatible sensors for hydraulic system monitoring of flow, pressure and temperature on pumps, valves and hydrostatic transmissions

Constant Running Hydraulic Pump Installation Guide. Document Number: Date: March 2006

INSERTION flowmeter with paddle wheel, ELEMENT design

Sanitary Turbine Flow Meter - TA3 Installation, Operating & Maintenance Manual

Liquid Turbine Flowmeter

1/4 Die Grinder. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

OVAL GEAR Medium capacity positive displacement flowmeters

OVAL GEAR Medium capacity positive displacement flowmeter

MidFlow _ 135. Sliding Vane Meters DN (1-2 ) Model PT / Fuel Oil Flowmeters135. Product Bulletin

OVAL GEAR. Medium Capacity Positive Displacement Mechanical Flowmeters. Models: 1 (D-150), 1½ (D-250), 2 (D-450) & 2" (D-580)

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

SIGNET 7002 Vortex Flow Sensor ENGLISH

TX 115/215 Hot-tap Insertion Turbine Instructions

Rotary Drive. Installation instructions. M81135: Type 1 Rotary Drive 12 V M81136: Type 2 Rotary Drive 12 V M81137: Type 2 Rotary Drive 24 V

Insertion magnetic inductive flowmeter

Pressure Transmitters

High Accuracy Mechanical Fuel meter FM-100

FLOWX3 F3.20 High Pressure Paddlewheel Flow Sensor MAIN FEATURES APPLICATIONS OPERATING PRINCIPLE

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

FTB 372 Series Axial Turbine Flow Meter

80 Litre Suction Oil Drainer With Inspection Chamber

Operating Manual Model- P282 Digiflow Controller

Transcription:

Installation & Maintenance Instructions MODEL MX75 3 OVAL GEAR FLOWMETER Supplied by.com Call us on +44 (0)118 916 9420 Email info@247able.com

MXL-INST75 Rev 1 06/2013 MODEL MX75 3 OVAL GEAR FLOWMETER INSTRUCTION MANUAL To the Owner Please read and retain this instruction manual to assist you in the operation and maintenance of this product. This manual contains connection and operating instructions for the MX series Flowmeters with Pulse outputs. Macnaught offer a comprehensive set web based support materials to compliment this instruction manual. Access the website by scanning the QR code below. Models with a Liquid Crystal Display have an additional LCD instruction manual supplied. If you need further assistance, contact your local representative or distributor for advice. This Flow Meter has incorporated the oval rotor principal into its design. This is proven to be a reliable and highly accurate method of measuring flow. Exceptional repeatability and high accuracy over a wide range of fluid viscosities and flow rates are features of the oval rotor design. With a low pressure drop and high pressure rating oval rotor flow meters are suitable for both gravity and (in-line) pump applications. WWW.MACNAUGHT.COM.AU Page 1 of 20

index Installation Pre-installation checks. Page 3 Operating Principle. Page 3 Installation Procedure. Page 3 Maintenance Procedure Disassembly. Page 4 Reassembly. Page 4 Flowmeter Specifications Flowmeter Specifications. Page 5 Electrical Specifications. Page 5 Wiring Diagram - Standard Pulser. Page 6 Wiring Diagram - PCB sensor. Page 7 Wiring Diagram - Intrinsically Safe Switch Page 8... Wiring Diagram - High Temperature Switch. Page 9 Service Troubleshooting Guide. Page 10 Maintenance Resources. Page 10 Exploded Diagram. Page 11 Spare Parts Kits. Page 12 Wetted Parts. Page 13 General Pressure Drop Graphs. Page 14 Dimensional Diagrams. Page 15-16 Page 2 of 20

IMPORTANT INFORMATION INSTALLATION PROCEDURE FLUID COMPATABILITY Before use, confirm the fluid to be used is compatible with the meter. Refer to Industry fluid compatibility charts or consult your local representative for advice. STRAINER To prevent damage from dirt or foreign matter it is recommended that a Y or Basket type 60 mesh strainer be installed as close as possible to the inlet side of the meter. When a strainer is installed it should be regularly inspected and cleaned. Failure to keep the strainer clean will dramatically effect flow meter performance. Contact your local representative for advice. AIR PURGE / LINE PRESSURE To prevent damage caused by air purge slowly fill the meter with fluid. To reduce pressure build-up turn off the at the end of each day. REED SWITCH The reed switch can cause inaccurate rate counts when used with high speed counters. It is advised that a low speed counter is used or alternatively a denounce circuit be installed. OPERATING PRINCIPLE Fluid passing through the meter causes the rotors to turn, as shown below. One of the rotors (the active rotor) is fitted with magnets. The passing of the magnets are picked up by the sensing elements (Reed and Hall Effect sensors) located in the Pulser Circuit Board. The excitation of these switches provides a Raw Pulse Output which relates to the K-Factor. (e.g. KF 2.58 = 2.58 pulses per litre of fluid passed) This Pulse Output Signal can either be fed directly to an external receiving element (e.g. Data Logger or PLC) or alternatively to an LC Display which conditions the Pulse input signal to display volume of fluid passed. (e.g. Display 1 Litre per 2.58 pulses received) 1) It is recommended that when setting up pipe work for meter installations a bypass line be included in the design. This provides the facility for a meter to be removed for maintenance without interrupting production. (see figure above) 2) Use thread sealant on all pipe threads. 3) For pump applications ensure pipe work has the appropriate working pressure rating to match the pressure output of the pump. See Meter Specifications section for further details. 4) Install a wire mesh strainer, Y or basket type 40 mesh (400 micron), as close as possible to the inlet side of the meter. 5) Ensure that the meter is installed so that the flow of the liquid is in the direction of the arrows embossed on the meter body. 6) The meter can be installed in any orientation as long as the meter shafts are in a horizontal plane. (Refer to figures to the right for correct installation) The register assembly may be orientated to suit the individual. Note: Incorrect installation can cause premature wear of meter components. 7) Do not over tighten meter connections. Note: Incorrect installation can cause premature wear of meter components. 8) It is important that after initial installation you fill the line slowly, high speed air purge could cause damage to the rotors. 9) Test the system for leaks. 10) Check the strainer for swarf or foreign material, after the first 200 litres check periodically, particularly if the flow rate decreases. Page 3 of 20

MAINTENANCE PROCEDURE DISASSEMBLY Ensure that the fluid supply to the meter is disconnected, and the line pressure is released before disassembly, with the exception for repair or maintenance to the LC Display or PCB where there is no necessity to isolate the meter from flow. Refer to the exploded parts diagram on subsequent pages for item numbers. 1) Pulse Caps Models: Undo the conduit connector, remove pulse cap and remove the wires from the pulse terminal board 2) Standard LC Display: Mark the display orientation with a marking pen, unscrew the four large screws on top of the LC Display. Carefully separate the LC Display from the plastic housing and disconnect the wires from the pulse terminal block. (Refer to additional LCD instruction manual accompanying these instructions). Remove the mounting adaptor plate and gasket. 7) Insert the cap head screws and tighten in a diagonal sequence 1, 3, 2, 4, etc. Torque = 33 Nm 8) The replacement of cables and connectors are a reversal of the disassembly procedure, replace conduit fitting if required. When replacing the Standard LC Display confirm the orientation marks made on disassembly are aligned then screw the register into place. 9) Test the meter by turning the rotors with a finger or by applying very low air pressure (no more than a good breath) to one end of the meter, before returning the meter to the line. 3) Loosen the cap head screws that hold down the meter cap remove the screws, washers and lift off the cap. 4) Remove the o-ring from the o-ring groove in the meter cap. 5) Remove rotors. REASSEMBLY 1) Before reassembling check the condition of the rotors (replace if necessary). 2) Check that the smooth side of the rotors (not the plug side) is facing you when inserting the rotors, the smooth side of the rotor is the magnet side. There is no difference between rotor one or rotor two. 3) Replace the rotors onto the shafts at 90 degrees to each other (refer Fig) and check their operation by turning either of the rotors. If the rotors are not in mesh correctly or do not move freely, remove one of the rotors and replace correctly at 90 degrees to the other rotor. 4) Re-check the operation of the rotors 5) Replace the o-ring into groove in the meter cap, if the o-ring has grown or is damaged in any way replace it with a new part. 6) Replace the meter cap making sure that the locating pin in the body lines up with the hole in the meter cap. Page 4 of 20

FLOWMETER SPECIFICATIONS Flowmeter Metric US Flow Range Below 5 cp 60 to 600 LPM 17 to 170 GPM 5 to 1000 cp 20 to 733 LPM 5 to 194 GPM K-Factor (Sensor Pulses per Unit of Measure) 2.58 pulses/l 9.77 pulses/g Max Temperature (model MX75F and MX75S) -40 C - 120 C -40 F - 248 F (models MX75P) -40 C - 150 C -40 F - 302 F Maximum Operating Pressure 1 1200 kpa 175 psi Accuracy of Reading ±0.5% 1. Conforms to Directive 97/23/EC Cat 1 High Viscosity Applications Ensure the Flowmeter is fitted with High Viscosity Rotors is the fluid being metered is 1000 cp or above High Viscosity Rotors For Fluids above 1000 Centipoise (cp) *Note: High Viscosity Rotor option available for models MX75S ELECTRICAL SPECIFICATIONS The MX Flow meter series is supplied with either a Blind Pulser and Digital Display option. Please note the wiring diagrams in the following pages are for the Blind Pulser Output Modules and the PCB (Sensor Board), which is responsible for providing a Raw Pulse input to the LC display If the Flow meter is supplied with an LC Display fitted, please consult the appropriate Instruction Manual, as advised below, for all programming and wiring instructions. Output option: type D type E type F type G type H Display Type : PR PRA ER ERA ERB ERS (remote mount only) Display Part Number: MXD-DS MXD-ES MXD-ES MXD-GS MXD-HS ERS-RMP / ERS-RMA Instruction Sheet: DR013 DR014 MS574 MS392 MS476 MS351 Analogue Output (4-20mA) Analogue outputs are available as an auxiliary display signal by including either of the following LC displays with your flowmeter. These may be fitted to the meter or remote (wall mount) types. PRA ERA 12mm LC Display with analogue output module 17mm LC Display with analogue output module Page 5 of 20

WIRING DIAGRAM 1 Standard Pulser Output type A Pulser Specifications Output Signals Standard Pulse Meter 2x Digital (Square Wave) Current Maximum 500mA Reed Switch (Mechanical Sensor) Voltage Maximum 30V DC Contact Rating Maximum 1 10W Hall Effect IC (Electronic Sensor) Maximum Current Operating Voltage Transistor Type 7.5mA 4.5V to 24V DC Open-Collector NPN 1. Contact rating maximum is 10W. Neither current nor voltage maximums should be exceeded in achieving this. NPN Hall effect Red +VE White Signal Black -VE Reed switch N/O Green +VE Yellow -VE Page 6 of 20

Off Pull-Up On WIRING DIAGRAM 2 PCB Output types D,E,F,G,H Reed Switch To maximise the life of the reed switch contacts, the pulse board comes equipped with a 1k8Ω current limiting resistor in series with the reed switch as standard. These resistors are user swappable should you require a different value for your system. NPN Open Collector Hall Effect Sensor The output for the hall effect sensor is NPN (current sinking, open collector). For correct operation, it is advisable to have a pull -up resistor installed. The hall effect sensor is equipped with a 1k8Ω pull-up resistor between signal and supply as standard. This in-built pull-up resistor can be bypassed by moving the jumper pin to the off position if required. A pull-up resistor of your choosing can be installed between signal and supply, provided the in-built pull-up resistor be bypassed first. Pulser Specifications Output Signals Standard Pulse Meter 2x Digital (Square Wave) Current Maximum 500mA Reed Switch (Mechanical Sensor) Voltage Maximum 30V DC Contact Rating Maximum 1 10W Hall Effect IC (Electronic Sensor) Maximum Current Operating Voltage Transistor Type 7.5mA 4.5V to 24V DC Open-Collector NPN 1. Contact rating maximum is 10W. Neither current nor voltage maximums should be exceeded in achieving this. Reed switch current limit Reed 1 Reed 2 + - Note: Local Display is connected to Reed 1 +Ve Hall effect built-in pull-up Reed 1 Hall Effect Reed 2 Signal Gnd + - Page 7 of 20

WIRING DIAGRAM 3 Intrinsically Safe (Ex ia) Output type B CAUTION: This sensor must be installed with an approved safety barrier. Pulser Specifications SENSOR TYPE Omni Polar Open-Collector NPN SPECIFICATIONS Construction Operating Voltage Maximum Current Temperature Range Stainless Steel Housing 5V to 30V DC 15mA -40-85oC -40-185oF Page 8 of 20

WIRING DIAGRAM 4 High Temperature Output type T Pulser Specifications SENSOR TYPE OMNI POLAR NPN SPECIFICATIONS Construction Operating Voltage Maximum Current Temperature Range Stainless Steel Housing 4.5 to 30V DC 18mA -40-150oC -40-302oF Page 9 of 20

TROUBLESHOOTING GUIDE Problem Cause Remedy Fluid will not flow through meter Reduced flow through meter Meter reading inaccurate Meter not giving a pulse signal LCD register not working a) Foreign matter blocking rotors b) Line strainer blocked c) Damaged rotors d) Meter connections over tightened e) Fluid is too viscous a) Strainer is partially blocked b) Fluid is too viscous a) Fluid flow rate is too high or too low b) Air in fluid c) Excess wear caused by incorrect installation a) Faulty hall effect sensor b) Faulty reed switch c) Magnets failed a) Battery not connected properly b) Battery flat c) Faulty wiring connections d) Faulty LC Display e) Faulty connection from LC Display a) Dismantle meter, clean rotors (strainer must be fitted in line) b) Clean strainer c) Replace rotors (Strainer must be fitted in line) d) Re-adjust connections e) See specifications for maximum viscosity a) Clean strainer b) See specifications for maximum viscosity a) See specifications for minimum and maximum flow rates b) Bleed air from system c) Check meter body and rotors. Replace as required. Refer to installation instructions a) Replace PCB Board b) Replace PCB Board c) Replace magnets a) Check battery connections b) Replace battery c) Check wiring for loose or faulty connections d) Replace LC Display e) Check wiring connections MAINTAINENCE VIDEOS Macnaught provides an comprehensive set of Maintenance Videos to assist the end user in all aspects of service and/or repair of the Flowmeter range. This web based resource can be accessed via the following URL http://www.macnaught.com.au/resources/ Or by scanning the QR code below. Page 10 of 20

EXPLODED DIAGRAM Parts Identification Item No. Part Description 1 Meter Body 2 Flanged Process Connection 3 Threaded Process Connection 4 Adaptor Bolts 5 Adaptor O-Rings 6 Meter Cap 0-Ring 7 Rotor Set 8 Meter Cap 9 Printed Circuit Board 10 PCB Mounting Screws 11 Meter Cap Screws 12 Pulser Cap Gasket 13 Pulser Cap 14 Pulser Cap Screws Page 11 of 20

SPARE PARTS KITS Spare Kit options, for both Flowmeter and Display/Pulser modules, are available as replacement components. Pulser Kit / LC Display Module - Replacement PCB complete with M-Lock electronic housing. - LC Display module (Electronic housing not included) Rotor Kit - Rotor assembly (includes Meter Cap bolts and O-Ring) Seal Kit - O-Rings/Gaskets (includes Meter Cap Bolts) SPARE KITS - FLOW- METER MX75F MX75S MX75P ROTOR KIT Standard MXS75F-rotor MXS75S-rotor MXS75P-rotor High Viscosity MXS75S-HVrotor MXS75P-HVrotor High Temp MXS75P-HTrotor SEAL KIT MXS75F-seal MXS75S-seal MXS75P-seal SPARE KITS DISPLAY AND PULSER MODULE Output Type Description Pulser Kit Display Module only Display/Pulser complete Type A Standard Pulser MXD-AS Type B Intrinsically Safe MXD-BS Type C Flameproof MXD-CS Type D PR Digital Register MXS-PCB-PR MXS-DIS-PR MXD-DS Type E PRA Digital Register MXS-PCB-PR MXS-DIS-PRA MXD-ES Type F ER Digital Register MXS-PCB-ER MXS-DIS-ER MXD-FS Type G ERA Digital Register MXS-PCB-ER MXS-DIS-ERA MXD-GS Type H ERB Batch Controller MXS-PCB-ER MXS-DIS-ERB MXD-HS Type T High Temperature MXD-TS Page 12 of 20

WETTED PARTS WETTED PARTS MX75F MX75S MX75P METER BODY Alum Alum St.St METER CAP Alum Alum St.St ROTORS - Standard Alum Alum St.St High Viscosity Alum ROTOR SHAFTS St.St St.St St.St ROTOR BUSHES CA CA O-RINGS FKM K K K - FEP/PTFE Encapsulated St.St - Stainless Steel 316 /304 Alum - Aluminium AA610 CA - Carbon FKM - Viton Page 13 of 20

PRESSURE DROP v s VISCOSITY 100% 50% 50% 10% 100% 25% 5% Page 14 of 20

METER DIMENSIONS Page 15 of 20

AIR ELIMINATOR / STRAINER COMBINATION 3 Flange 3 Threaded Connection Page 16 of 20

NOTES Page 17 of 20

NOTES WEEE Directive - Waste Electrical and Electronic Equipment The WEEE Directive requires the recycling of waste electrical and electronic equipment in the European Union. Whilst the WEEE Directive does not apply to some of Macnaught s products, we support its policy and ask you to be aware of how to dispose of this product. The crossed out wheelie bin symbol illustrated and found on our products signifies that this product should not be disposed of in general waste or landfill. Please contact your local dealer national distributor or Macnaught Technical Services for information on product disposal. Page 18 of 20

EC Declaration of Conformity EC Declaration of Conformity In accordance with EN ISO 17050-2004 We: Of: Macnaught Pty Ltd 41-47 Henderson St Turrella NSW 2205 AUSTRALIA Declare that: Macnaught Flow Meters prefixed MX, F, CR, M or S in accordance with the following Directive; 2006/42/EC Machinery Directive (and its amending directives) have been designed and manufactured to the following specifications; EN ISO 12100:2010 Safety of Machinery Declare that: Macnaught Flow Meters prefixed MX, F, CR, M or S with flange nominal bores sizes 1 to 6 inclusive in accordance w with the following Directive; 97/23/EC Pressure Equipment Directive (and its amending directives) comply with the essential requirements of the Directive, classification Category 1 Group 1 Declare that: Macnaught Flow Meter accessories prefixed DR, ER or PR as fitted to the Flow Meters or remotely mounted in accor dance with the following Directive 2004/108/EC Electromagnetic Compatibility Directive (and its amending directives) have been designed and manufactured to the following specifications; EN61326-1:2006 Electromagnetic Compatibility Electrical equipment for measurement, control and laboratory use. I hereby declare that the equipment named above has been designed to comply with the relevant sections of the above referenced specifications. The product complies with all essential requirements of the Directives. This declaration is no longer valid if the unit is modified without our agreement. Name: Steven Gavin Position: Operations Director Date: 21/06/2013 Done at: Macnaught Pty Ltd 41-49 Henderson St Turrella NSW 2205, AUSTRALIA Issue 6 QA-CN5573 Issued by: Graham Wilson Page 19 of 20

Page 20 of 20