Flexible Arm Stand F 360. User Manual

Similar documents
PRIMA DNT User Manual

XPERT SL 45 Slit Lamp. Instruction Manual

Prima OPH User Manual

Original Operating Manual

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

Pressure relief valve

Operating instructions ErgoPack 600 E

OPERATING INSTRUCTIONS

Installation instructions BasicRelay CR / / 2012

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM

Part Number Mini Linear Lift Assembly Installation & Operator s Instruction Manual

User s Manual Power Supply IM E. 5th Edition

The information in this instruction manual is subject to modifications without prior notice and is the exclusive property of Zorzini.

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

Exchange of rollers from the XTS-Mover

HST-BL-2830MS & HST-BL-2830MS-USA

Angle seat valve with piston actuator VZXA-...-K

Catalyser Introduction. 3. Hazard Information. 2. Area of Application. 3.1 Symbology

HST -LS Interlocking device (Translation of Original Manual)

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve

Assembly instructions PRORUNNER mk1 2

Turbocharger / A100-L Original assembly instructions English

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

MOTORIZED FOLDING CAMPER WINCH

Single and Double Head Powered Screed. Screed King. User Manual. SCR-UM EN-04 (December 2018)

Prime Attachments & Custom Fab Brush Mower Owners/Operators Manual

KeContact P20. User manual

BEFORE YOU BEGIN LIST OF COMPONENTS. Isopropyl SWITCH SCOTCH-BRITE PAD ALCOHOL PREP PAD SWITCH HARNESS REVOLVER PCM COVER STICKER

Installation Guide VHM Wall Mount Kit for Philips MX600/700/800 and MP60/70 IntelliVue

User s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation

User s Manual Power Supply. IM E 3rd Edition. Yokogawa Electric Corporation

MANUAL. Single charger

Operating Instructions

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Nokia Mobile Holder CR-123 & Easy Mount HH-22 User Guide

Owners Manual Öhlins road & track front fork FG 43 Including:

Instructions for Fitting, Operating and Maintenance Canopy Door RE / (St.: )

Turbocharger / TPS-H Original assembly instructions English

Hard Seat Fluid Pressure Regulator

Operating Instruction for Downlights

Swing Arm Magnifying Lamp

Original operating manual

Mod: KLD6-12/35XLAS-N

Assembly and Maintenance Manual Type ASNU

Water Level Meter + Temperature

Installation Guide. Philips MP20/30/40/50 IntelliVue VHM Wall Mount Kit

Operating Instructions

Big & Tall Chair Assembly Instructions

Operating Instructions

INSTRUCTION MANUAL. A PEX S1 DAMPER Height Adjustable Coilover Damper Kit PRODUCT CODE - 268AM020

COBRA Indoor base with gas pressure spring and 45 tilt function user manual

Installation Guide VHM Arm Kit for Philips Heartstart MRx and Heartstart XL+

PET UNIT DOSE TABLE INSTALLATION MANUAL FN: Rev A 1/18

Assembly and Maintenance Manual Type AS

Mounting and Operating Instructions EB 8048 EN. Type and Type Pneumatic Control Valves Type 3249 Aseptic Angle Valve

57-1. Front door. Tools. Special tools and equipment. T Socket 3320/2 Bit insert for Socket T Assembly tool

Spare Parts List Return line filter RF

Big & Tall Chair Assembly Instructions

BK BK J93 MA BK MA BK MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

RO Automatic trailer coupling. Repair instructions. 5KPVM02000 Towing Hitch Automatic Rockinger RO244A

Linear Actuator. Installation Manual. warranty installation parts list. Linear Actuator Installation Manual Page 1

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

User manual Pipe notcher Type: AL 1-2E

Declaration of Conformity as per Directive 97/23/EC

Mounting and Operating Instructions EB 8097 EN. Type and Type Pneumatic Control Valves

MODEL NO & UP SAFETY INSTRUCTIONS. Keep this Operator s Manual in the plastic tube behind the operator seat.

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Original Operating Manual

Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS

0-800 psi Carbide Seat Fluid Pressure Regulator

Soft Seat Fluid Pressure Regulator

0-500 PSI Soft Seat Fluid Pressure Regulator

VHM-P (Non-Locking) Variable Height Arm with VESA Mounting Plate for 75 x 75mm or 100 x 100mm applications

USER MANUAL. WINN CUT Edger. Read the instructions carefully and understand them before using WinnCut.

Re.Formance Line INSTRUCTION MANUAL 1703

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use!

Instructions for INSTALLATION -- OPERATION -- MAINTENANCE of the SELAS AIR/GAS BLENDER VALVE. (for PROPANE/AIR, BUTANE/AIR AND OTHER BLENDS)

IMPORTANT READ ME FIRST

RSV16 Retro-Fit Cartridge Acorn Controls SV16 Valve Cartridge

3875 Cypress Drive Petaluma, CA Fax

Installation instructions

Model 2310 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

Heavy Duty Steel Motorcycle Carrier. Instructions for Part # MCC-600

VARIFUEL MAINTENANCE AND REPAIR INSTRUCTIONS

MANUAL FLUID EXTRACTOR

Instruction manual. RP800 - HYDRAULIC actuator, load 150Kg. RP815 - LINAK actuator, load 150Kg

Operating Instructions K Always on the safe side.

Crane Forks. Introduction. Important Notes. Key Benefits. User Guide

US Patent 0540, 400 Other Patents Pending. Read this manual completely before assembling and riding our PET PRO-FLEX 500. Always wear a Helmet!

Drive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions

(Refer to qualified personnel)

User Manual and Parts List. P/n:

VARIFUEL MAINTENANCE AND REPAIR INSTRUCTIONS

DYNAFLUID 2000 STEAM & WATER MIXING VALVE INSTALLATION & OPERATING MANUAL

Fiber Optic Illuminator. Model 21AC Model 21DC

Double piston rotary drive DRQD-6/... / b [ ] (en) Operating instructions

Katalysator Nr /

Installation, Maintenance and Warranty Flat Plate Battery

SAFETY. Read and understand all safety precautions and instructions before installing this product.

Transcription:

User Manual To ensure proper use of this instrument as well as to avoid injury while operating instrument, understanding this manual completely before use is highly recommended.

Flexible Arm Stand User Manual For purchasing a Labomed - an excellent choice! With outstanding features of sturdy design and absolutely maintenance-free performance. It is easily adaptable for all your requirements ensuring vibration-free observation due to its solid and flexible design. You may use it for different requirements like manufacturing tasks, testing, quality control and other industrial applications. We have placed great emphasis on simple, intuitive operation. However, please take the time to read the user manual and the notes on operating safety to learn about all the features and capabilities to use them to your best advantage. Should you have any questions, please consult your local Labomed representative. We are glad to be at your service!

TABLE OF CONTENTS 1. Important Notes and Brief Description 1 2. Safety Instructions 2-3 3. Direction for Use 4 4. Maintenance, Cleaning, Accessories and Repair 5 5. Overview of Labomed 6 1. Table Clamp...6 2. Rotatable Arm...6 3. Flexible Arm...6 4. Fastening Lever for Height Adjustment...6 5. Horizontal Arm...6 6. Connection to the Focusing Arm...6 7. Power Supply...6 6. Assembly and Use 7-8 Table Clamp Instructions for Safe Assembly...7 Assembling the Table Clamp...7 Adjusting the Table Clamp...7 Flexible Arm Stand and Focusing Arm Load Capacity...8 Assembly...8 Working Height Adjustment...8 7. Spring Tension Adjustment 9 Tool Requirement...9 Factory Settings...9 Adjusting the Spring Force...9 8. Dimensions 10

1 IMPORTANT NOTES AND BRIEF DESCRIPTION This user manual provides important instructions for operational safety, maintenance and accessories. Adhere to local regulations related to accident prevention and environmental protection. Electrically operated accessories are compliant to EC Declaration of Conformity. The Labomed Flexible Arm Stand serves as a flexible holder for the Labomed stereomicroscopes 6z and 6i UMS (Universal Mounting System) models. The flexible arm stand must be placed on a solid vibration free substrate. The flexible arm stand can be used in clean rooms without any problems. 1

2 SAFETY INSTRUCTIONS Symbols used in this operating manual This symbol indicates especially important information that is mandatory to read and observe. Failure to comply can cause the following: Hazards to personnel Instrument malfunctions and damage This symbol indicates especially important information that is mandatory to read and observe. Failure to comply can cause the following: Hazards to personnel Instrument malfunctions and damage This symbol indicates additional information or explanations that are intended to provide clarity. Non-intended use Using the flexible arm stand in any way other than that described in the user manual may result in personal injury or damage to property. Doing so can impair the functions of the protective measures provided. The instruments and accessories described in this user manual have been tested for safety and potential hazards. The responsible Labomed affiliate must be consulted whenever the flexible arm stand is modified or used in conjunction with non-labomed components that are outside of the scope of this manual! Unauthorized alterations or non compliant use shall void all rights to any warranty claims. 2

SAFETY INSTRUCTIONS (continued) For use of the original packaging recommended for shipping or transporting individual modules. In order to prevent damage follow instructions according to this user manual. For disposal must comply with locally applicable laws and regulations. If the flexible arm stand is used with non-labomed products: The manufacturer of the complete system or the person putting it on the market is responsible for adhering to applicable safety regulations, laws and guidelines. Use of Stereomicroscope helps in improving the viewing task, but it may also cause stress on eyes and posture holding muscles depending upon using chairs. To overcome this, appropriate measures related to work layout, training and working time duration must be taken. Kindly follow notes on safety during use by reffering microscope manual. 3

3 DIRECTIONS FOR USE Use of this flexible arm stand is used only by persons qualified to do so. Always ensure availability of this manual at work place. Carry out regular audits to ensure that trained and authorized users are following required safety procedures. For new users, explain thoroughly the meanings of the warning signs and messages. Allocate responsibilities for commissioning, operation and maintenance. compliance with this. Inform your Labomed representative immediately of any product defect that could potentially cause injury or harm. The use of accessories or cables other than those specified, with the exception of those sold by the manufacturer as replacement parts for the immunity of the equipment or system is not recommended. If this instrument is modified, appropriate inspection and testing must be conducted to ensure continued safe use of this instrument. Only original Labomed replacement parts may be used in servicing the product. Modifications to this instrument are not allowed. Any modification to this unit must be authorized by Labomed or serious injury to the operator may occur. 4

4 MAINTENANCE, CLEANING, ACCESSORIES AND REPAIR The flexible arm stand is absolutely maintenance-free. For Maintenance and repair, only OEM spare parts may be used. Remove coarse debris with a moistened disposable cloth. Dirt can be removed using petroleum ether or alcohol. Acetone, Xylene or nitro-containing thinners must not be used. Use only Labomed recommended accessories with this flexible arm stand. Use only original Labomed spare parts. Before any repair, the power must be shut off and the power cables disconnected. 5

5 OVERVIEW OF LABOMED FLEXIBLE ARM STAND F 360 7 6 5 4 3 2 6 1. Table clamp Tabletop thickness up to 100 mm Min. space required on table: 100 105 mm 2. Rotatable arm Can be rotated 360 Fixed at 15 angle to facilitate freedom of movement of specimen. 3. Flexible arm Can be rotated 360 Weight balance: 1.5 7 kg (factory setting 2.7 kg) 470 mm height adjustment Smooth guide adjustment 4. Fastening lever for height adjustment 5. Horizontal Arm 6. Connection to the focusing arm Allows connection of focusing arms with standard pin diameter of of 16 mm. 7. Power Supply Output - 24 Volts Input - 100-240 V Universal Power Supply 6

6 Table clamp ASSEMBLY AND USE Instructions for safe assembly The table clamp is designed for tabletops with a thickness of up to 100 mm. Before installation, ensure that the selected tabletop is strong enough to carry the weight. Otherwise the microscope may not function properly or user may get injured and damage to microscope specimen may happen. Assembling the Table Clamp 1. Push the table clamp over the tabletop completely. 2. Tighten the two clamping screws shown as (a) referring Fig. 1. 3. Insert the flexible arm into the table clamp. 4. Tighten the clamping knob shown as (c) referring Fig. 2. a b Fig. 1 Adjusting the Table Clamp Table clamp has 6 holes (4 are covered with a hole plug) to adjust according to table thickness. If the table clamp does not fit the thickness of the tabletop, you can adjust it by unscrewing the two screws shown as (b) and move the loose part of the clamp as required and refix the hole plug referring Fig. 1. c Fig. 2 7

ASSEMBLY AND USE (continued) Flexible Arm Stand and Focusing Arm Load capacity d This flexible arm stand is designed for a load capacity of ranging 1.5 7 kg to keep the stereomicroscope in balance without tightening the fastening lever. You can lock the working height if necessary by tightening the fastening lever. e f Assembly 1. Unscrew clamping knob (e) on the horizontal arm. 2. Loosen the knob (d) of UMS and tilt the connecting pin (f) in 90 as shown as Fig. 3. 3. Push in the connecting pin (f) completely and clamp the knob (e) as shown in Fig. 4. g Fig. 3 Working Height Adjustment 1. Move the flexible arm to the desired height according to the object under inspection. 2. Tighten the fastening lever (h) if necessary to protect the stereomicroscope from unwanted height adjustment as shown in Fig. 5. Fig. 4 h Fig. 5 8

7 SPRING TENSION ADJUSTMENT Tool Requirement 13 millimeter socket wrench (not included in the delivery package) a Factory settings The spring force for the flexible arm is factory set to approx. 2.7 kg and can be adjust by turning screw clockwise reffering Fig. 8. Fig. 6 Adjusting the spring force 1. Remove the socket screw (a) above the cover by using allen wrench 2.5mm as shown in Fig. 6. 2. Remove the cover. 3. Unscrew the fastening lever shown as (b) in Fig. 7. 4. Change the spring force using the screw in the interior as shown in Fig.8. b Fig. 7 Fig. 8 9

DIMENSIONS FlexibleArm Stand F 360 860 300 400 160 max. 100 145 58 102 105 860 10

www.laboamerica.com Our policy is one of continuous development. Labo America, Inc., reserves the right to change design and specifications without prior notice. Labo America Inc. 920 Auburn Court Fremont, CA94538 U.S.A. Telephone: 510 445 1257 Fax: 510 445 1317 sales@laboamerica.com CE LABOMED and are registered trademarks of Labo America. Inc. With a policy of continuous development, Labo America, Inc. reserves the right to change design and specifications without prior notice. 2010 Labo America, Inc.