Technical Data. Dimensions

Similar documents
SERIES 54 Inductive Proximity Sensor

SERIES 54 PROXIMITY SENSORS

Ex m Solenoid Operator Type 0519

INSTRUCTION MANUAL (ATEX / IECEx)

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

OPERATING INSTRUCTIONS

INSTRUCTION MANUAL (ATEX / IECEx)

Segurança. Segurança. PSB Heating System Cold applied connection technology. Compulsório. Compulsório. Operation Manual and Installation Instructions

Solenoid coil for control in potentially explosive areas Type BZ

Type Z & Ex pz purge and pressurization system

Operating Instructions

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX

Sensor boxes SRBE Key features and product range overview

Segurança. Segurança. MSB/HSB Heating System. Compulsório. Compulsório. Operation Manual/Installation Instructions. Cold applied connection technology

EStrong-series Emergency Stop

Control and Terminal Box Type A21-**-*****

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

XXV18B1PAL2 Ultrasonic sensor - M18 metal - Sn 50mm - PNP NO - cable 2m

Segurança. Segurança. PSB Heating System Heat shrink technology. Compulsório. Compulsório. Operation Manual/Installation Instructions

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Magnetic Field Sensor for pneumatic cylinders BIM-UNT-AP6X-0.3-PSG3S/3GD

Solenoid coils VACF Type codes

Capanivo Series CN 4000

Assembly. Trunk IN + - S U, I U, I. Spur 1

Operating Instructions

XT130B1NAL2 capacitive sensor - XT1 - cylindrical M30 - brass - Sn 10 mm - cable 2 m

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

ZB0050 / ZB0051 ZB0070 / ZB0071

XMLR160M2P05 Pressure sensors XMLR 160bar - G 1/4-24VDC - 2xPNP - M12

Accessories for pneumatic stroke and rotary actuators CLASSIC and ELEMENT process valves

Holtumsweg 13, D Weeze, Tel /9134-0, Fax /1444

Instruction Manual. Ex-Time 40 / 50

YFC. Limit switch. Ex d. 24 operating head types

Solenoid Valves Type 3963

Surface thermocouple Model TC50

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

3/2 and 4/2 directional seat valves with solenoid actuation

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13

HIGH VOLTAGE TEF 1060 HV ENCLOSURE WITH A-BLOCK SOLUTIONS USER MANUAL

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

Solenoid Operator 0516 / 1216

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

ILED Dorado. User Manual

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

PTB 14 ATEX 2023 X, EPS 16 ATEX 1046 X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

VALIADIS S.A. HELLENIC MOTORS

Control Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations

International approvals.

Thermocouple Without thermowell Model TC10-H

Safety Standards. Model Number:

A good connection. International approvals.

Cable resistance thermometer Model TR40

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Resistance thermometer Without thermowell Model TR10-H

11mm Slot Label S1 = 162, S2 = 170, S3 = 250, S4 = 305, S5 = 330, S6 = 410, S7 = 490, S8 = 570, S9 = 650. Maximum Power Dissipation (Watts) T** T**

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Product Overview. Rotary Encoders for Potentially Explosive Atmospheres (ATEX)

Terminal Boxes in Stainless Steel SLS**.T

XMLRM01G1P25 Pressure sensors XMLR -1 bar - G 1/4-24VDC ma - PNP - M12

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

Fieldbus Segment Protector F2-SP-IC* Features. Assembly. Function. Connection. Zone 2 Div. 2

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series

LIMIT SWITCH Hawkeye - HX Magnetic Solid State Proximity Sensors Installation, Maintenance and Operating Instructions (HX )

Emergency Luminaire with LED Series EXLUX 6409/1

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

Operating Instructions for Float Flow Meter / Monitor. Model: SWK

Measuring insert for process resistance thermometer

Emergency lighting units EM converterled

Thermocouple For additional thermowell Model TC10-B

Emergency lighting units EM converterled. EM converterled BASIC 50 V BASIC series

Compact temperature switch Model TCS

Operating instructions Solenoid interlock EX-AZM About this document. Content

Operating Instructions for Paddle Flow Monitor. Model: PSR-..., PSE-...

XMLR400M1N26 Pressure sensors XMLR 400bar - 1/4" 18 NPT - 24VDC ma - NPN - M12

Compact Sheet-Steel Light Fittings Series 6114/1

XMLR400M1N75 Pressure sensors XMLR 400bar - G 1/4-24VDC V - NPN - M12

Operating instructions Safety sensor EX-CSS About this document. Content. 7 Disassembly and disposal 7.1 Disassembly Disposal...

Control Buttons / Switches for Panel Mounting Series 8003

9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Linear Luminaire with LED Series EXLUX 6402/2

Dimensions shown apply to both Stainless Steel and Mild Steel S1, SF*1 = 162, S2, SF*2, S2L, SF*2L = 170, S3, SF*3 = 250,

HTSB system System overview

Emergency lighting units EM converterled. EM converterled BASIC 200 V BASIC series

Pneumatic control unit for decentralized automation of ELEMENT process valves

Emergency lighting units EM converterled

PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22.

LED Linear Luminaire Series EXLUX 6402

M-0. M-0... series control, monitoring and signalling devices. Ex e

97300 NAMUR 3/2 & 5/2 way spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, NAMUR Interface

Sense7-series Non-contact coded safety switch

EX-REPAIR AND MAINTENANCE RECEPTACLES

Transcription:

Model Number Features 40 mm flush 4-wire DC ATEX-approval for zone 2 and zone 22 S Technical Data specifications Switching element function PNP NO/NC Rated operating distance s n 40 mm Installation flush Output polarity DC Assured operating distance s a 0... 32.4 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.23 Reduction factor r 304 0.85 Nominal ratings Operating voltage U B 10... 60 V DC Switching frequency f 0... 80 Hz Hysteresis H typ. 3 % Reverse polarity protection Voltage drop U d 3 V Operating current I L 0... 200 ma Off-state current I r 0... 0.5 ma No-load supply current I 0 20 ma Time delay before availability t v 300 ms reverse polarity protected Operating voltage indicator LED, green Switching state indicator LED, yellow Functional safety related parameters MTTF d 630 a Mission Time (T M ) 20 a Diagnostic Coverage (DC) 0 % Ambient conditions Ambient temperature -25... 70 C (-13... 158 F) Mechanical specifications Connection type screw terminals Core cross-section up to 2.5 mm 2 Housing material Sensing face Housing base Degree of protection IP68 information Use in the hazardous area see instruction manuals Category 3G; 3D Compliance with standards and directives Standard conformity Standards EN 60947-5-2:2007 IEC 60947-5-2:2007 Approvals and certificates UL approval culus Listed, Purpose CSA approval ccsaus Listed, Purpose CCC approval Certified by China Compulsory Certification (CCC) Dimensions LEDs ø 9.5 40 M20 x 1.5 11 7 ø 5.3 80 65 65 LEDs 1

Electrical Connection 1 4 2 3 L+ L- Installation Hint These sensors are especially designed for embeddable mounting in conveyor floors. Due to its precise location in metal base plates the sensor is afforded a high degree of mechanical protection. No clearance is required between the sensor and the base plate, avoiding the need for protective guarding to prevent possible foot injury. The large sensing range ensures positive detection, and thus provides consistent control and monitoring of the conveyor. 2

ATEX 3G (na) Device category 3G (na) Certificate of Compliance for use in hazardous areas with gas, vapour and mist PF 15CERT3754 X II 3G Ex na IIC T6 Gc The Ex-related marking can also be printed on the enclosed label. Standards EN 60079-0:2012+A11:2013, EN 60079-15:2010 Ignition protection category "n" Use is restricted to the following stated conditions The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be observed! Laws and/or regulations and standards governing the use or intended usage goal must be observed. If the Ex-related marking is printed only on the supplied label, then this must be attached in the immediate vicinity of the sensor. The sticking surface for the label must be clean and free from grease. The attached label must be legible and indelible, including in the event of possible chemical corrosion. After opening the housing, you should check that the seal is in the correct position and is clean and intact before closing the housing again. Repairs to these apparatus are not possible. After opening the housing, you should check that the seal is in the correct position and is clean and intact before closing the housing again. The maximum permissible load current must be restricted to the values given in the following list. High load currents and load short-circuits are not permitted. Maximum operating voltage U Bmax The maximum permissible operating voltage UB max is restricted to the values in the following list. Tolerances are not permissible. Maximum permissible ambient temperature T Umax dependant of the load current I L and the max. operating voltage U Bmax. Information can be taken from the following list. 44 C (111.2 F) 45 C (113 F) 51 C (123.8 F) 55 C (131 F) 56 C (132.8 F) at U Bmax =30 V, I L =25 ma 57 C (134.6 F) Protection from mechanical danger The sensor must not be exposed to ANY FORM of mechanical danger. Protection from UV light The sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas. Protection against transients Ensure transient protection is provided and that the maximum value of the transient protection (140% of 85 V) is not exceeded. When used in group IIC non-permissible electrostatic charges should be avoided on the plastic housing parts. Avoid electrostatic charges that can cause electrostatic discharge when installing or operating the device. Information on electrostatic hazards can be found in the technical specification IEC/TS 60079-32-1. If cable glands are required for the installation then the following points must be observed: The cable glands must be certified in accordance with the application. The temperature range of the cable glands must be selected according to the application. The degree of protection must not be reduced by the cable glands. Seal the housing. Use a seal that meets the requirements of the application. Material selection accessories When selecting accessories, ensure that the material allows the temperature of the enclosure to rise to up to 70 C. The plug connector must not be withdrawn under voltage. The proximity switch is identified as follows: "WARNING - DO NOT SEPARATE WHEN ENERGIZED". With the plug connector disconnected, soiling of the internal area must be prevented.(i.e. the area that is inaccessible when the connector is inserted) 3

ATEX 3D Note Device category 3D This instruction is only valid for products according to EN 50281-1-1, valid until 30-September-2008 Note the ex-marking on the sensor or on the enclosed adhesive label for use in hazardous areas with non-conducting combustible dust II 3D IP67 T 96 C (204.8 F) X Standards EN 50281-1-1 Protection via housing Use is restricted to the following stated conditions The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be adhered to! Laws and/or regulations and standards governing the use or intended usage goal must be observed. Repairs to these apparatus are not possible. The maximum permissible load current must be restricted to the values given in the following list. High load currents and load short-circuits are not permitted. Maximum operating voltage U Bmax The maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are not permitted. Maximum heating (Temperature rise) dependant of the load current I L and the max. operating voltage U Bmax. Information can be taken from the following list. The maximum surface temperature at maximum ambient temperature is given in the Ex identification of the apparatus. 26 K 25 K 22 K 22 K 19 K 15 K 13 K Protection from mechanical danger The sensor must not be mechanically damaged. Connections for external wire Sliding contact discharges must be avoided. s must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. Terminal connection: Minimum conductor cross-section: 0.5 mm 2, maximum conductor cross-section: 2.5 mm 2. The ends of the conductor must be provided with cable sleeves. The cable entry must be such, that no tension load or twist is applied to the cable The protection category must be in accordance with EN 60529 and as stated in the data sheet. The cable entry must be designed so that there are no sharp edges to damage the cable and impair the level of protection of the sensor. The cable entry must be in accordance with the relevant European standard for industrial cable and lead entries.. In addition, in the case of flexible leads, the points of entry of the cable must be rounded off over an angle of at least 75, with a radius (R), which is at least one quarter of the maximum permissible cable diameter for the entry, but not greater than 3 mm. The plug connector must not be disconnected under voltage. The proximity switch is marked as follows: "DO NOT DISCON- NECT UNDER VOLTAGE!" When the plug connector is disconnected the ingress of dirt into the inner areas (i.e. the areas, which are not accessible in the plugged-in condition) must be prevented. 4

ATEX 3D (tc) Device category 3D Certificate of Compliance for use in hazardous areas with combustible dust PF 15CERT3774 X II 3D Ex tc IIIC T80 C Dc The Ex-related marking can also be printed on the enclosed label. Standards EN 60079-0:2012+A11:2013, EN 60079-31:2014 Protection by enclosure "tc" Some of the information in this instruction manual is more specific than the information provided in the datasheet. The corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.pepperlfuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet. Laws and/or regulations and standards governing the use or intended usage goal must be observed. If the Ex-relevant identification is printed exclusively on the adhesive label provided, this label must be affixed in the immediate vicinity of the sensor! The background surface to which the adhesivelabel is to be applied must be clean and free from grease! The applied label must be durable and remain legible, with due consideration of the possibility of chemical corrosion! After opening the housing, you should check that the seal is in the correct position and is clean and intact before closing the housing again. Repairs to these apparatus are not possible. After opening the housing, you should check that the seal is in the correct position and is clean and intact before closing the housing again. The maximum permissible load current must be restricted to the values given in the following list. High load currents and load short-circuits are not permitted. Maximum operating voltage U Bmax The maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are not permitted. Maximum permissible ambient temperature T Umax dependant of the load current I L and the max. operating voltage U Bmax. Information can be taken from the following list. 44 C (111.2 F) 45 C (113 F) 51 C (123.8 F) 55 C (131 F) 56 C (132.8 F) Protection from mechanical danger The sensor must not be exposed to ANY FORM of mechanical danger. Protection from UV light The sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas. Sliding contact discharges must be avoided. Avoid electrostatic charges that can cause electrostatic discharge when installing or operating the device. Information on electrostatic hazards can be found in the technical specification IEC/TS 60079-32-1. Do not attach the nameplate provided in areas where electrostatic charge can build up. Connections for external wire Terminal connection: Minimum conductor cross-section: 0.5 mm 2, maximum conductor cross-section: 2.5 mm 2. The ends of the conductor must be provided with cable sleeves. If cable glands are required for the installation then the following points must be observed: The cable glands must be certified in accordance with the application. The temperature range of the cable glands must be selected according to the application. The degree of protection must not be reduced by the cable glands. Seal the housing. Use a seal that meets the requirements of the application. The plug connector must not be withdrawn under voltage. The proximity switch is identified as follows: "WARNING - DO NOT SEPARATE WHEN ENERGIZED". With the plug connector disconnected, soiling of the internal area must be prevented.(i.e. the area that is inaccessible when the connector is inserted) 5