ISTEC MAGNETIC METERS MEASURE ANY CONDUCTIVE LIQUIDS OR SLURRIES (EVEN ABRASIVE OR CORROSIVE) WITH THE NEW MICROPROCESSOR-BASED MAGNETIC METER -- A QUALITY PRODUCT - SIMPLE - RELIABLE - AT AN AFFORDABLE PRICE. VISCOSITY, DENSITY AND PRESSURE DO NOT EFFECT THE ACCURACY AND PERFORMANCE. THESE METERS CAN BE INSTALLED HORIZONTALLY OR VERTICALLY, EVEN NEXT TO ELBOWS. THE IDEAL CHOICE FOR A NON-RESTRICTIVE FLOWMETER ADVANCED ENGINEERING DEPENDABILITY HIGH ACCURACY WIDE FLOW RANGE LOW PRICE - GREAT VALUE ANOTHER FINE PRODUCT WITH THE ISTEC TRADEMARK Our Magnetic Meter Line Includes: Series 6000 Flowmeters Series 6100 Flowmeters Series 6200 Flowmeters Series 6300 Flowmeters Series 6400 Flowmeters Series 6910 Converters Series 6920 Converters Series 6930 Converters
TECHNICAL SPECIFICATIONS Electromagnetic Flowmeter 6000 Series Description Ideal for measurement of liquids with electrical conductivity and characterized by high accuracy (± ¼%) over a user selectable flow range, simple installation, long service life and ease of maintenance. The meter s accuracy is unaffected by the liquid s physical characteristics (density, temperature, viscosity, ph, etc.) The 6000 Series Electromagnetic Meters Feature: 1/8", ¼", 3/8", ½", and ¾" sizes for flows from 0.1 gpm to 50 gpm The standard pressure is compatible for 225 PSIG services at ambient temperatures or less Designed for liquid temperatures up to 300 F 316 Stainless Steel male NPT threaded ends. NPT Hastelloy or tri-clamp ends optional PTFE liner in stainless steel flow tube Electrode material choices including: 316 stainless steel (standard), Hastelloy B, Hastelloy C, Titanium, Tantalum and Platinum Polished 304 stainless steel coil housing offers excellent water resistance, even when immersed Remote converter installation Converter/ Readout The 6000 Series meters may be coupled with either the 6910 (standard,) 6911, 6920, 6930 or 6931 converter in a remote configuration to power the meter s coils and process created voltage, converting voltage into flow data. The 6930 series is a full featured unit incorporating multiple alarms and multiple output signal choices. The lower cost 6920 is a multi-feature unit including the most customerdesired features, including display, alarm and output choices. Both the 6930 series and 6920 converters incorporate a programmable keypad and on-unit LCD
Display. The economical 6910 series converter offers a single choice output with local or remote reading and with or without display. Calibration and Measurement The 6000 meters are Group B1, ISO 11631 devices. Every meter is wet calibrated by either a traceable device or primary standard. The maximum accuracy error is given by the following choices: ±.25% when flows are in the user-set 10:1 range of 3 ft/sec to 36 ft/sec ±.50% outside the 10:1 range, for flows between 1 ½ ft/sec and 36 ft/sec Typical Applications Pacing additive chemicals, most acids, strong bases, pharmaceuticals, food and beverage, or most other conductive liquids. 6000 Series Operating Characteristics and Dimensions Pipe Size (A below) Characteristic/Dimension 1/8" 1/4" 3/8" 1/2" 3/4" Maximum Flow [Qmax] (gpm) at Vmax 36 ft/s 1.4 5.5 12.5 22 50 Standard Weight (lbs) 4.2 4.2 4.2 4.2 4.2 Standard Length 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" Standard Width 3 3/8" 3 3/8" 3 3/8" 3 3/8" 3 3/8" Standard Height 4 ¾" 4 ¾" 4 ¾" 4 ¾" 4 ¾" Connecting NPT Thread Size (NPT) ¼" 3/8" ½" ¾" 1 Overall Dimensions
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. TECHNICAL SPECIFICATIONS Electromagnetic Flowmeter 6100 Series 6100-Series Electromagnetic Flowmeter Description Ideal for measurement of liquids with electrical conductivity and characterized by high accuracy (± ¼%) over a user selectable flow range, simple installation, long service life and ease of maintenance. The meter s accuracy is unaffected by the liquid s physical characteristics (density, temperature, viscosity, ph, etc.) The 6100 Meter features: 1 ½" to 12" sizes for flows from 8 gpm to 12,700 gpm. Standard pressure compatible with ANSI 150 Ratings. Designed for either rated pressures up to 300 PSI (at ambient temperatures) or liquid temperatures up to 356 F. 4-20 ma Output. Choice of Converters, including 6910 (standard). The 6911, 6930 and 6931 Converters are also available for use with this meter. Choice of Grounding Rings, including 316 SS Grounding Rings (Standard). Hastelloy Grounding rings are also optional with this meter. A PTFE liner in Stainless Steel flow tube. Electrode material choices, including 316 stainless steel (standard), Hastelloy B, Hastelloy C, titanium, tantalum and platinum. Epoxy, double coated coil housing for excellent water resistance, even when immersed. Converter installation options. Reduced dimensions allowing for use with flanges of ANSI 150 and ANSI 300 to 6". Priced below flanged designs. Converter/ The 6100 Series is coupled with a 6910 Converter with a single choice output unit,
Readout Installation Requirements Calibration and Measurement available for either local or remote reading. The 6911 converter is also available, with a display. The 6920 and 6930-Series Converters are also available with this meter. These converters are full-featured, incorporating alarms, multiple output signal choices, password protected external keypad and on-unit Liquid Crystal Display. The 6100 Series has no flanges and is installed between pipe flanges and tightened with all-thread rods or long bolts. The 6100 Series is a Group B1, ISO 11631 device. Every meter is wet calibrated by either a traceable device or a primary standard. The maximum accuracy error is given by the following choices: ±.25% when flows are in the user-set 10:1 range of 3ft/sec to 36 ft/sec ±.50%, outside the 10:1 range. For flows between 1 ½ ft/sec and 36 ft/sec Typical Applications Raw water, waste water, low concentration slurries, abrasive liquids, pulp & paper, food beverage or most other conductive liquids. Meter Operating Characteristics and Dimensions Pipe Size (D Below) Characteristic/Dimension 1 1/2" 2" 3" 4" 6" 8" 10" 12" Maximum Flow [Qmax](gpm) at Vmax 36ft/s 90 350 800 1,400 3,175 5,300 8,800 12,700 Standard Weight (for ANSI 150) (lbs.) 4.7 6.6 14.3 16.5 24.3 26 48 66 Standard Length (for ANSI 150) [A Below] 3.94" 3.94" 5.91" 5.91" 7.09" 7.87" 9.84" 11.81" Standard Width (for ANSI 150) [B Below] 3.5" 4.1" 5.4" 6.2" 8.4" 11.2" 12.8" 14.8" Local Converter Mount [C Below] 1.4" 1.4" 1.4" 1.8" 1.8" 3.3" 3.3" 3.3"
Overall Dimensions 6100 Configured for Remote Converter 6100 with Local 6910 Converter 6100 with Local 6920/6931 Converter Horizontal Mounting Vertical Mounting SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
TECHNICAL SPECIFICATIONS Electromagnetic Flowmeter 6200 Series 6200-Series Electromagnetic Flowmeter Configured for remote reading Description Cost-effective, high accuracy (± ¼%) measurement, over a user-selected flow range, of conductive liquids compatible with the unit s polypropylene liner. The Electromagnetic Flowmeter is characterized by simplified installation, long service life and ease of maintenance. The meter s accuracy is unaffected by the liquid s physical characteristics (density, temperature, viscosity, ph, etc.) The 6200 Series Electromagnetic Flowmeters Feature: 1 ½", 2", 3", 4", and 6" sizes for flows from 8 gpm to 3200 gpm Standard pressure compatible with ANSI 150 ratings Polypropylene (PP) liner in stainless steel flow tube Standard third electrode for liquid grounding Electrode material choices including 316 stainless steel (standard), Hastelloy B, Hastelloy C, titanium, tantalum and platinum Epoxy, double-coated coil housing for excellent water resistance, even when immersed Converter installation options: 6910 (standard), 6911, 6920, 6930 and 6931 4 20 ma output Reduced dimensions allowing for use with ANSI 150 flanges Full forward and reverse flow capability
Priced well below flanged designs Converter/ Readout Installation Requirements Calibration and Measurement The 6200-Series meters may be coupled with 6910 (standard), 6911, 6920, 6930 or 6931 converter in either a local or remote version to power meter and process the created voltage, converting the voltage into flow data. The 6930-Series Converters are full-featured, incorporating multiple alarms, multiple output signal choices, programmable password-protected external keypad and on-unit LCD display. The 6920 Series are multi-featured, including the most user-desired features, including display, alarm and output choices. The lower cost 6910 Series is a single choice output unit. The 6200 Series have no flanges and are installed between the pipe flanges and tightened with all-thread rods or long bolts. The 6200 Series is a Group B1, ISO 11631 device. Every meter is wet calibrated by either a traceable device or a primary standard. The maximum accuracy error is given by the following choices: ±.25% when flows are in the user-set 10:1 range of 3 ft/sec to 36 ft/sec ±.50%, outside the 10:1 range, for flows between 1½ ft/sec and 36 ft/sec Typical Applications Raw water, waste water, low concentration slurries, mildly abrasive liquids, and many other conductive liquids compatible with the polypropylene liner. Electromagnetic Flowmeter Operating Characteristics and Dimensions Pipe Size (D below) Characteristic/Dimension 1 ½" 2" 3" 4" 6" Maximum Flow [Qmax] (gpm) at Vmax 36 ft/s 200 350 800 1400 3175 Standard Weight (for ANSI 150) (lbs.) 4.7 6.6 14.3 16.5 24.3 Standard Length (for ANSI 150) [A below] Standard Width (for ANSI 150) [B below] 3.9" 3.9" 5.9" 5.9" 7.1" 3.5" 4.1" 5.4" 6.2" 8.4" Converter Stand-off [C below] 1.4" 1.4" 1.4" 1.8" 1.8" Recommended Mating Flanges 2" X 1 1/2" Reducing 3" X 2" Reducing 4" X 3" Reducing 4" ANSI 150 6" ANSI 150 Overall Dimensions 6200 Configured for Remote Converter 6200 with Local 6910 Converter
6200 with Local 6920/6931 Converter Horizontal Mounting Vertical Mounting SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
TECHNICAL SPECIFICATIONS Electromagnetic Flowmeter 6300 Series 6200-Series Electromagnetic Flowmeter Configured for remote reading Description Ideal for measurement of liquids with electrical conductivity and characterized by high accuracy (± ¼%) over a user selected flow range, simple installation, long service life and ease of maintenance. Th meter s accuracy is unaffected by the liquid s physical characteristics (density, temperature, viscosity, ph, etc.) The 6300 Series Electromagnetic Flowmeters feature: 10", 12", 14", 16", 18", 20", 24", 30", 36" and 42" sizes for flows from 490 gpm to 155,000 gpm Standard pressure compatible with ANSI 150 ratings Designed for rated pressures up to 300 PSI (at ambient temperatures) or liquid temperatures up to 200 F Epoxy coated carbon steel or optional 304 stainless steel flanges to 16" diameter Hard rubber liner in stainless steel flow tube Electrode material choices including 316 stainless steel (standard), Hastelloy B, Hastelloy C, titanium, tantalum and platinum Epoxy, double coated coil housing offering excellent water resistance, even when immersed for short periods of operation Flexible converter installation 4 20 ma output Full bi-directional flow capacity Converter/ Readout The 6300 Series may be coupled with our 6910 (standard), 6911, 6920, 6930 or 6931 converters in either a local or a remote version. These converters power the meter coils and process created voltage, converting voltage into flow data. The 6930 Series converters are full featured units incorporating multiple alarms and output signal choices. The lower cost 6920 converter is a multi-feature unit including the most customer-desired features, including display, alarm and output choices. Both
the 6930 Series and 6920 converters incorporate a programmable external keypad and on-unit LCD Display. The economical 6910 Series converters offer a single choice of output with on-unit or remote programming and with or without display. Installation Requirements Calibration and Measurement When installed in an insulating pipe the two grounding rings provided should be inserted between the gasket surfaces and pipe flanges both upstream and downstream. The 6300 Series meters are Group B1, ISO 11631 devices. Every meter is wet calibrated by either a traceable device or primary standard. The maximum accuracy error is given by the following choices: ±.25% when flows are in the user-set 10:1 range of 3 ft/sec to 36 ft/sec ±.50% outside the 10:1 range, for flows between 1 ½ft/sec and 36 ft/sec Typical Applications Raw water, waste water, low concentration slurries, abrasive liquids, pulp & paper, food & beverage, or most other conductive liquids. Electromagnetic Flowmeter Operating Characteristics and Dimensions Pipe Size (C below) Characteristic/Dimension 10" 12" 14" 16" 18" 20" 24" 30" 36" 42" Maximum Flow [Qmax] at Vmax 36 ft/sec 8800 12700 17300 22500 28500 35300 50800 79400 114000 155000 Coil Housing Width [A below] 14.0" 17.5" 18.7" 20.7" 24.2" 26.2" 32.6" 41.3" 43.9" 48.4" Coil Housing Height [B below] 16.1" 18.5" 20.9" 23.0" 24.6" 27.8" 32.6" 41.3" 43.9" 48.4" ANSI 150PSI Flanges Flange Diameter [D below] 15.6" 17.5" 19.9" 22.2" 24.2" 26.4" 30.7" 40.0" 43.9" 48.4" Length [E below 11.8" 11.8" 19.8" 15.7" 17.7" 19.7" 23.6" 31.5" 35.4" 39.4" Weight (pounds) 165 242 330 380 462 550 770 1100 1232 1430 Number of Bolts 12 12 12 16 16 20 20 28 32 36 ANSI 300 PSI Flanges Flange Diameter [D below] 16.7" 19.1" 21.9" 24.4" 26.4" 28.7" 33.3" NA NA NA Length [E below] 11.8" 13.8" 15.7" 21.7" 23.6" 23.6" 23.6" NA NA NA Weight (pounds) 241 344 480 564 702 850 1280 NA NA NA Number of Bolts 16 16 20 20 24 24 24 NA NA NA
Overall Dimensions 6300 Series Configure d for Remote Reading 6300 Series with Local 6910 Converter SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
TECHNICAL SPECIFICATIONS Electromagnetic Flowmeter 6400 Series 6400-Series with 6910 Converter Description Ideal for measurement of liquids with electrical conductivity and characterized by high accuracy (± 1/4%) over a user selectable range, simple installation, long service life and ease of maintenance. The meter s accuracy is unaffected by the liquid s physical characteristics (density, temperature, viscosity, ph, etc.) The 6400-Series Electromagnetic Flowmeter features: 1", 1 ½", 2", 3", 4", 6" and 8" sizes for flows from 5 GPM to 5300 GPM The standard pressure is compatible with ANSI 150ratings Designed for rated pressures up to 900 PSI (at ambient temperatures) or liquid temperatures up to 356 F Epoxy coated carbon steel or optional 304 stainless steel flanges PTFE liner in a stainless steel flow tube (8" standard with hard rubber liner) Electrode material choices: 316 stainless steel (standard), Hastelloy B, Hastelloy C, titanium, tantalum and platinum Double coated epoxy coil housing offers excellent water resistance, even when immersed Converter installation options: 6910(standard), 6911, 6920, 6930 and 6931 Converter/ Readout Installation Requirements The 6400-Series may be coupled with either the 6910(standard), 6911, 6920, 6930 or Readout 6931 converter in either a local or a remote version. The 6930 converter is full-feaured; Incorporating multiple alarms and output signal choices. The lower cost 6920 converter is a multi-feature unit including the most customer-desired features, including display, alarm and output choices. Both the 6920 and 6931 converters incorporate a programmable external keypad and on-unit LCD Display. The 6911 converter is very economical and offers the same features as the 6910 converter, but with a display. When installed in an insulating pipe, the meter should either be ordered with the optional third grounding electrode or two liquid grounding rings should be inserted
between the gasket surfaces and pipe flanges, both upstream and downstream. Calibration and Measurement The 6400 meters are Group B1, ISO 11631 devices. Every meter is wet calibrated by either a traceable device or a primary standard. The maximum accuracy error is given by the following choices: ±.25% when flows are in the user-set 10:1 range of 3ft/sec to 36 ft/sec ±.50%, outside of the 10:1 range, for flows between 1 ½ ft/sec and 36 ft/sec Typical Applications Raw water, waste water, low concentration slurries, abrasive liquids, pulp & paper, food & beverage or most other conductive liquids. 6400 Series - Operation Characteristics and Dimensions Pipe Size (C below) Characteristic Dimension 1" 1 1/2" 2" 3" 4" 6" 8" Maximum Flow [Qmax] (GPM) at Vmax36ft/s 90 200 350 800 1400 3175 5300 Standard Weight (for ANSI 150) (lbs.) 19.8 30.9 33.1 50.7 57.3 94.8 154.3 Standard Length (for ANSI 150) [A below] 7.9" 7.9" 7.9" 10.6" 10.6" 11.8" 11.8" Standard Width (for ANSI 150) [B below] 4.6" 6.5" 6.5" 8.8" 8.8" 12.3" 13.6" Number of Bolts (for ANSI 150) 4 4 4 4 8 8 8
Local Meter Version with 6920/6931 Converter Remote Meter Version Vertical Mounting Horizontal Mounting SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
TECHNICAL SPECIFICATIONS Electromagnetic Flowmeter 6910 Series Converters Remote 6911 Converter Description: The 6910-Series Converters are minimum feature, cost-effective converters that power the Electromagnetic Flowmeter and process created voltage, converting the voltage into flow data. Flow data is then either transmitted to another device (6910/6911) or displayed on the unit with Liquid Crystal Display (6911.) 6910-Series Converter Features: Compatible with all of our Electromagnetic Flowmeters Local Models for liquid temperatures up to 200 F. Remote converter for use with meter configurations up to 356 F Programmable choice of single output including totalization, scaleable 0 1 khz frequency, maximum or minimum flow alarm, empty pipe alarm, hardware failure alarm, automatic scale change or direct or reverse flow rate. 4 20 ma output RS485 interface for network connections Designed for use in ambient temperatures ranging from -4 F to 140 F Pressure die-cast aluminum case featuring IP65 protection Local or Remote mounting choices LCD Display available on 6911 models
6910 Series Dimensions SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
TECHNICAL SPECIFICATIONS Electromagnetic Flowmeter 6920 Series Converters Remote 6920 Converter Description: The 6920 Converter is a multi-feature, multiple output, user-programmable converter incorporating the most common user-preferred features and output. The 6920 Converter powers the Electromagnetic Flowmeter Sensor coils and processes created voltage, converting that voltage into flow data. Flow data can be transmitted to another device and/or displayed on the unit. Standard 6920 Converter Features: Compatible with all of our Electromagnetic Flowmeters Available for either local or remote reading Temperature range: -4 F to 140 F ambient Accuracy (Maximum): ± 0.50%, at a range of 10:1, for flows between 1 ½ ft/sec to 36 ft/sec Repeatability: ± 0.1% Die-cast aluminum IP67-rated case Display: Two line 16-Character display Keypad: Easy access 6-key front panel for programming and display control Data Display Flow rate: Engineering units or Percent or Full Scale Volume: total forward flow, total reverse and partial forward and reverse flows (partial totalizers can be used to determine net forward and reverse flows. Alarms, choice of one: Empty pipe, overflow, underflow, hardware problems Flow direction Programming Levels View only: no configuration or alarm changes Level 1(basic configuration): password protected configuration changes Level 2: password protected changes to all configuration parameters and alarms Outputs Flow rate: 4-20 ma output to a maximum load of 1000 ohms or Frequency
0-1250 Hz Volume: 24 VDC pulse output, user scaled to standard measurement Power Supply 90 to 264 volt, 45/66 Hz keyboard-selected or 16 to 28 VAC, 45-66 Hz, or 19-33 VDC Power consumption: 3 to 17 watts, depending on Electromagnetic Flowmeter size SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
TECHNICAL SPECIFICATIONS Electromagnetic Flowmeter 6930 Series Converters Remote 6931 Converter Description The 6930 Converters are full-featured, multiple-output, user-programmable converters that feature second-generation micro-electronics for lower power operation and enhanced capability. The 6930 Converters power the Electromagnetic Flowmeter coils and process created voltage, converting that voltage into flow data. Flow data can be transferred to another device and/or displayed on the unit. Standard features of the 6930 Converter include: Available for either local or remote reading Designed for use in ambient temperatures ranging from -4 F to 140 F Maximum accuracy error is given by the following: ± 0.25% when flows are in the user-set 10:1 range of 3 ft/sec to 36 ft/sec. ± 0.50%, outside the 10:1 range, for flows between 1 ½ ft/sec. And 36 ft/sec. Automatic flow range adjustment providing maximum accuracy through full available flow range Automatic empty pipe detection and totalizer cut-off Standard choice of one output alarm: minimum or maximum flow rate, empty pipe, reverse flow or overflow/automatic scale change alarm User set low flow cut-off from 0 to 25% of full scale value 4-20 ma output to a maximum load of 1000 ohms Configurable choice of 0-2.5 khz digital output Galvanically insulated outputs