WATER LEVEL INDICATOR. Model CPR. Roctest Limited, All rights reserved.

Similar documents
TAPE EXTENSOMETER Model CONVEX-D. Roctest Limited, All rights reserved.

VIBRATING WIRE FILL EXTENSOMETER. Model ERI. Roctest Limited, All rights reserved.

INSTRUCTION MANUAL ANCHOR LOAD CELL. Model ANCLO

VIBRATING WIRE SURFACE STRAIN GAUGE. Model SM-5B. Roctest Limited, All rights reserved.

POINT LOAD TESTER. Model PIL-7. Roctest Limited, All rights reserved.

FIBERGLASS RODS BOREHOLE EXTENSOMETER WITH GROUTABLE ANCHORS AND VW SENSORS Model BOREX-E. Roctest Limited, All rights reserved.

Solinst Water Level Meter Model 101

VIBRATING WIRE DISPLACEMENT TRANSDUCERS. JM Series. Roctest Limited, All rights reserved.

VW Embedment Jointmeter

CONTACT WATERRA. WS-2 REELCASE WATER LEVEL TAPE

SENSOPTIC FIBER-OPTIC DISPLACEMENT TRANSDUCER. Model FOD. Roctest Limited, All rights reserved.

Marin Control Digital

RETRIEVABLE BOREHOLE EXTENSOMETER. Model BOF-EX. Roctest Limited, All rights reserved.

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

WARNING. This product uses High Brightness LEDs. Direct viewing of the SMD LEDs at close range should be avoided. Keep product away from children.

HTR-202 INSTRUCTION MANUAL. Portable Digital Height Rod. Befour, Inc. 102 Progress Drive Saukville, WI 53080

RTD Assembly TH15. Compact Instructions. KA195R/24/ae/

PowerWorx DSX Series GMT Fuse Panel User Manual

(450 m-925 m) ET/MDPE Tape Water Level Meter (with optional electric rewind)

Fiberglass Rod Extensometer

Introduction. What is Powercore? Powercore Welding Rod is an " Electro-fusion System" used for joining all types of thermoplastic parts together.

Manufacturing & Service: Bierer & Associates Inc. Patent No. 6,885,180. ST Series Service Tester Phase Identifier Operating Instructions ST500PGN

Hydraulic Immediate Need Power Pack

T-REX T-REX INCREMENTAL EXTENSOMETER SETTLEMENT GAUGES

Instruction Manual Model 4422 Monument Crackmeter

ABSOLUTE EQUIPMENT PTY LTD

ABSOLUTE EQUIPMENT PTY LTD

Holiday Detector. Model EPT/AC-30 High Voltage Coating Test Instrument Brief Description

TABLES & CONVERSIONS. Linear Conversions. Mass Conversions. Area Conversions. Mass per Area Conversions. Area per Volume Conversions

MF205, MF205-4, MF210, MF210-4, MF220 & MF220-4 Compact

AFT mid drive kit Trouble shooting guide For 24v to 48V Kelly Controller KBS 48101L-L 100 A peak

MPT-250B SPECIFICATIONS AND OPERATING INSTRUCTIONS

Installation Guide The RSi brief overview:

For additional information, please visit our website at SENSOR SPECIFICATIONS

Fiber Splice Panel Rack Mount User Manual

MOTION-ACTIVATED WALL LANTERN

TABLE OF CONTENTS GENERAL INFORMATION

3M Cold Shrink QT-III Silicone Rubber Termination

Model Ton Hand Carry Axle Jack P/N: CJ67D0250-1

6.0 SPECIFICATIONS CONTENTS. Calibration. According to factory procedureeeeeeeeeeeeeee Accuracy*

FLP-2492/KLP-4492 Impeller Flowmeter

No Infrared Refrigerant Leak Detector

RS-110 Rainfall Sensor Installation Guide

Rosemount 402 and 402VP

Installation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet.

SERVICE MANUAL. STARTER Portable Meter ST300 ST300C ST300D ST400D. Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ (973)

Instruction Manual Part No

Heavy Duty Sprayer Owners Manual Model MS-O

Vibrating Wire Crackmeter User Manual

PowerWorx Power Distribution Products Select Series Circuit Breaker for ±24 or ±48 Vdc User Manual

CGD8800X CGD8800X220 Combustible Gas Detector

COMPACT - TRAINING MANUAL

SBP2 Pendant Pushbutton Stations Installation Instructions

(K),(M)430TB/G Up to 36 kv

Instruction Manual Model 4450

8,1,8,1,2,7,2,7,6,3,6,3,4,5,4,5

Tracer VM with User Interface

Cold Shrink - Silicone Rubber QTII(X)4S-32H Series Cable Termination Instructions

Tension your belts at the speed of light!

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits

Installation of Hydraulic Disc Brake System with the ActiBrake Actuator Sand Drive Fort Worth, Texas

Tracer VMA with AutoReg

ALUMAREEL. Electrical Cord Reel. Model EC6 100 Model EC Operational, Maintenance and Installation Manual

OPERATING INSTRUCTION MANUAL MS SERIES CONDUCTIVITY CELLS

TIF8800X. Combustible Gas Detector. an spx brand. Owner s Manual. 99 Washington Street Melrose, MA Phone Toll Free

Refinery Supply Company, Inc.

Geotech Interface Meter

Explosion proof RTD assembly T15

Deep-Water EL Tiltmeter

Water Level Meter + Temperature

innovations in battery charging

Appendix. Conversion Factors LENGTH

TM-1620 OPERATING INSTRUCTIONS AND OWNERS MANUAL

innovations in battery charging

Universal Splice Tray Installation Instructions

CP-1TT Remote System

Electric Trolling Motor

Hydraulic PTO Flow Device

Deep Cycle Battery Safety. First. Battery Handling, Maintenance & Test Procedures

FHC-1D user manual. Features

QS-III. 5513A, 5514A, 5515A and 5516A 15 kv Cold Shrink Inline Splice Kits. Data Sheet CAUTION. 1. Product Description. 2. Applications.

ELECTRIC ACTUATOR AND CONTROLLER FOR AKRON BUTTERFLY VALVES INSTALLATION INSTRUCTIONS

WATERFLUX 3070 Quick Start

WPS500X. 500 psi / 34.5 bar Automotive Pressure Transducer. User s Guide

STUDIO - TRAINING MANUAL

IMPORTANT SAFETY INSTRUCTIONS VP200ESK SAFETY INSTRUCTIONS 1

Sondex Settlement System

KEEP FOR FUTURE REFERENCE DC VACUUM BACK-UP SYSTEM READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT

Functional Description and Specifications. Intended Use. Packing List

Hand Held Pull Tester Instruction Manual Order No

Model 2053 Conductivity Meter Instruction Manual

Instruction Manual. Model VW Displacement Transducer

Instruction Manual. RZ Positive Displacement Flowmeters 2AU

Installation Instruction EPP /92

High Performance Vacuum Pump Model 15120A/15121A Operating Manual...

Installation Instructions Light Commercial & Irrigation Water Pressure Booster System

GL0098P Beta+ Septic Tanks Installation & Operation Guidelines

SERVICE THE GORMAN-RUPP COMPANY P.O. Box 1217 MANSFIELD, OH FX

(K),(M),(P)489TB/G Up to 42 kv

Relius UV-Cure Adhesive Coating Dispenser Manual

Transcription:

INSTRUCTION MANUAL WATER LEVEL INDICATOR Model Roctest Limited, 2006. All rights reserved. This product should be installed and operated only by qualified personnel. Its misuse is potentially dangerous. The Company makes no warranty as to the information furnished in this manual and assumes no liability for damages resulting from the installation or use of this product. The information herein is subject to change without notification. Tel.: 1.450.465.1113 1.877.ROCTEST (Canada, USA) 33.1.64.06.40.80 (France) 41.91.610.1800 (Switzerland) www.roctest-group.com E1003C-060314

TABLE OF CONTENTS 1 APPLICATIONS... 1 2 PRODUCT... 1 2.1 General description... 1 2.2 Operation principle... 2 3 READING PROCEDURE... 2 3.1 Generalities... 2 3.2 Taking measurements... 2 3.3 Quick verification of measurements... 3 3.4 Data recording sheet example... 3 4 MAINTENANCE... 3 4.1 Battery condition and replacement... 3 4.2 Cleaning... 3 4.3 Splicing procedure... 4 5 TROUBLESHOOTING... 5 5.1 Unstable reading... 5 5.2 No reading... 5 6 MISCELLANEOUS... 6 6.1 Tape elongation... 6 6.2 Environmental factors... 7 6.3 Conversion factors... 7 i

1 APPLICATIONS The model water level indicator is used to measure the depth of water in boreholes, standpipes and wells. The model, a light and compact unit, offers an accurate and fast readout of the water depth. 2 PRODUCT 2.1 GENERAL DESCRIPTION The water level indicator consists in a probe connected to a graduated tape wrapped on a reel. A control panel is incorporated into the reel. It has the standard full complement of accessories. The indicator light and the buzzer provide a clear signal when the probe contacts water. The On-Off sensitivity switch ensures optimum battery life and allows the operator to compensate for variations in the conductivity of saline or contaminated water. The probe is specially designed for either static or water well draw-drown measurements. The brass electrode is recessed within a fluted tip to prevent the indicator from sounding prior to contact with the static or pumping water level. A convenient holder is mounted on the reel stand for probe storage. Two types of flat tape are available: - a black one: the EVAT model with permanent hot stamped graduations - a yellow one: the PCST model with an extruded transparent polyethylene jacket Figure 1: Model water level indicator Page 1

2.2 OPERATION PRINCIPLE The probe is lowered into the borehole. When the probe is in contact with water, a circuit is completed, causing the light to turn on and activating the buzzer on the control panel on the reel. The water level depth is then measured using the graduations on the tape. 3 READING PROCEDURE 3.1 GENERALITIES To prevent damage, do not submerge probe beyond the detection depth. Only the model with 11 mm diameter probe assembly ( 6) is submersible. Note: The readout unit on the reel may support light rain, but is not waterproof. Keep it out of rain or wet mud. For minimizing errors, be sure that the same procedure is used by all technicians. It is important to take the readings with the same reference, usually the top of the piezometer tube. To get an absolute reading of the water level, use an optical survey method to measure the tube collar elevation. When the tape inside the borehole is longer than 150m, it is sometime difficult to lower the probe until the water level because of the friction of the tape along the well walls. In order to ease the insertion, a ballast can be fixed to the probe body. Please contact the Roctest Group for more information. 3.2 TAKING MEASUREMENTS Before taking readings, proceed with the two following operations: - Check the charge of the battery. Please refer to the maintenance paragraph for more information. - Check the good functioning of the probe by putting it in contact in a glass of clear water. - Adjust the sensitivity of the probe using the On/Off switch on the control panel. Sensitivity is set properly if both the buzzer and light turn off immediately when the probe is removed from contact with water. Use a low sensitivity for saline or contaminated water or to reduce false triggering. Increase the sensitivity for less conductive water. Lower the probe into the borehole until the buzzer sounds. Keep lowering it by a few centimetres in order to check the continuity of the sound. This indicates that the probe is in free water and not only in condensation. Pull up the probe until the sound stops and move it slowly up and down to accurately Page 2

determine the water level. Fix the tape and take the readings using the graduations and the top of the piezometer tube. Be sure to turn off the unit after using the instrument to maximize battery life. 3.3 QUICK VERIFICATION OF MEASUREMENTS On site, several verifications can be done to prevent a bad measurement. - Compare readings to previous ones. Are they in the same range? Are they changing slowly or abruptly? Consider external factors that can affect the measurements like construction activities, rain, tide - In any case, it is advised to take several readings to confirm the measurement. Then, repeatability can be appreciated and dummy readings erased. 3.4 DATA RECORDING SHEET EXAMPLE Please refer to Appendix 1 at the end of the instruction manual. 4 MAINTENANCE 4.1 BATTERY CONDITION AND REPLACEMENT To test the battery condition, turn on the sensitivity button to the maximum clockwise position and push the black button labelled battery test on the control panel. If the battery level is correct, when the button is pushed, the buzzer sounds and the red indicator light on the panel turns on. If the readout battery has to be changed, remove the large slotted head screws located on the control panel. Slowly lift the control panel using caution not to pull any wiring located behind the panel. The battery holder is located on the back side of the control panel. Replace battery with a 9 volt alkaline battery. Be sure the battery connector is securely in place, and the battery is in its holder. Replace control panel. 4.2 CLEANING It is a good practice to dry probe and tape after each use. If it is necessary to clean the measuring tape, use a soft cloth and clean water. Rinse off any mud or sand before wiping the cable. The use of chemical cleaners or solvent is not recommended. Excessive cleaning or use of other cleaning methods may damage the plastic protection and the cable markings. Do not remove the plastic tip from the probe! Removing the probe tip destroys the waterproof integrity of the probe and will cause damage to the electrical connections. Repairs resulting from probe tip removal will not be covered under warranty. Page 3

4.3 SPLICING PROCEDURE If the graduated tape is damaged or cut, a splicing kit is available (only for EVAT model). Please contact the Roctest Group for more information. The splicing kit consists of the following parts: - 1 small shrink tubing (10 cm x 3.2 mm), to be cut in two parts - 1 medium shrink tubing (10 cm x 6.4 mm) - 1 large shrink tubing (10 cm x 9.5 mm) - A length of soldering tin cored silver wire - 4 pieces of adhesive extruded sealer (2.5 cm) - A new probe with some tape length In order to repair the tape, follow the procedure described below. Step 1 Strip the extremity of both cables and cut to get one lead approximately 0.7 cm long and the other approximately 3 cm. Step 2 Step 3 Step 4 Tin the tip of each lead. Thread the larger shrink tubing on one of the extremities of the cable and the medium one on the other one. Thread the small shrink tubing on each lead. Step 5 Step 6 Lay the cables as shown on drawing above, and then solder each lead. Cover each solder joint with a small shrink tubing, and then heat with a heat gun as to get a result similar to the following drawing. Step 7 Step 8 Step 9 Cover the two wires with the medium shrink tubing and heat it to fix it. Fill the space around the joint with a length of adhesive extruded sealer. Cover with the long shrink tubing, and then heat with a heat gun as to get a result similar to the following drawing. Page 4

5 TROUBLESHOOTING Keeping the readout unit with its probe clean and dry as well as a secure storage decreases its chance to fail. 5.1 UNSTABLE READING - Check the battery of the readout unit. - Reduce the sensitivity of the probe. - Is water in the borehole generally quiet (no bubbling)? - Turn the readout off and clean the probe in clear water. - Check the good functioning of the probe into a glass of clear water. If trouble occurs, the readout unit may be suspected and the factory should be consulted. The probe may have been partially damaged also. 5.2 NO READING - Check the battery of the readout unit. - Increase the sensitivity of the probe. - Turn the readout off and clean the probe in clear water. - Check the good functioning of the probe into a glass of clear water. If trouble occurs, the readout unit may be suspected and the factory should be consulted. The probe may have been partially damaged also. - Check the integrity of the measuring tape. Sides of it enclose conductor wires. Cuts or shorts are located, the factory should be consulted. Page 5

6 MISCELLANEOUS 6.1 TAPE ELONGATION In most cases, it is not necessary to estimate the elongation of the measuring tape. However, for huge cable lengths, the calculation details are given below. The measuring tape is stretched due to the weight of the probe and the centralizer and to its own weight. Submitted to 4.0 kg, the elongation is 1 mm for 4.5m of PCST tape. To be able to estimate the elongation value, the useful weights are indicated in the following table. Model component Weight in kg PCST tape only (200 m) 3.940 Probe 0.065 Table 1: Weight of each component of model instrument Because the main cause of the elongation is the weight of the tape itself, it is necessary to distribute its weight all along it. Use the following relation to calculate the elongation of the tape: mt e = kl L + m p 2 where e = elongation of the tape in millimetres k = cable elongation in mm/(m.kg) L = length of the tape in meters m t = weight of the tape per length (kg/m) m p = weight of the probe in kilograms Example: (using PCST tape and data above) With L = 100 m, 0. 020 We get: e = 0. 056 100 100 + 0. 065 = 6.0 mm 2 Page 6

6.2 ENVIRONMENTAL FACTORS Since the purpose of a piezometer installation is to monitor site conditions, factors which may affect these conditions should always be observed and recorded. Seemingly minor effects may have a real influence on the behaviour of the structure being monitored and may give an early indication of potential problems. Some of these factors include, but are not limited to: blasting, rainfall, tidal levels, excavation and fill levels and sequences, traffic, temperature and barometric changes, changes in personnel, nearby construction activities, seasonal changes, etc. 6.3 CONVERSION FACTORS To Convert From To Multiply By LENGTH AREA VOLUME MASS FORCE PRESSURE AND STRESS TEMPERATURE Microns Millimetres Meters Square millimetres Square meters Cubic centimetres Cubic meters Litres Litres Kilograms Kilograms Kilograms Newtons Newtons Newtons Kilopascals Bars Inches head of water Inches head of Hg Pascal Kilopascals Kilopascals Kilopascals Inches Inches Feet Square inches Square feet Cubic inches Cubic feet U.S. gallon Can Br gallon Pounds Short tons Long tons Pounds-force Kilograms-force Kips Psi Psi Psi Psi Newton / square meter Atmospheres Bars Meters head of water Temp. in F = (1.8 x Temp. in C) + 32 Temp. in C = (Temp. in F 32) / 1.8 3.94E-05 0.0394 3.2808 0.0016 10.7643 0.06101 35.3357 0.26420 0.21997 2.20459 0.00110 0.00098 0.22482 0.10197 0.00023 0.14503 14.4928 0.03606 0.49116 1 0.00987 0.01 0.10197 at 4 C E6TabConv-990505 Table 2: Conversion factors Page 7

Appendix 1 Example of water level data sheet Page 8