Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

Similar documents
Deliveryprogramme. Overloadrelay,6-9A,1N/O+1N/C. Articleno CatalogNo. XTOM009AC1. Settingrange. Auxiliarycontacts. Short-circuitprotection

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Contactelement,1N/C,frontmount,6.contact,screwconnection. Product range RMQ-Titan (drilling dimensions 22.5 mm)

Deliveryprogramme. Overloadrelay,24-40A,1N/O+1N/C. Articleno CatalogNo. XTOB040DC1. Auxiliarycontacts. Short-circuitprotection

Application Mini Contactors for Motors and Resistive Loads

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC mm

Application Mini Contactors for Motors and Resistive Loads

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

Miniaturecircuitbreaker(MCB),6A,1Np,C-Char,AC. Application Switchgear for industrial and advanced commercial applications.

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

Overloadrelay,10-16A,1N/O+1N/C. Articleno

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Product range RMQ-Titan (drilling dimensions 22.5 mm) Description Cage Clamp is a registered trademark of Wago Kontakttechnik GmbH/ Minden, Germany

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Product range RMQ-Titan (drilling dimensions 22.5 mm) Description Cage Clamp is a registered trademark of Wago Kontakttechnik GmbH/ Minden, Germany

Subrange SmartWire-DT electronic motor starters. Basic function Reversing starters (complete devices)

Flexible. Intelligent. Trendsetting.

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

PKZ and PKE motor-protective circuit-breakers

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

CA Z-EN Overload relays, CT-operated overload relays

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

MS General Information Extended Product Type: MS

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Technical Information

Protection Equipment

Electronic overload relay EF65, EF96 and EF146

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

Catalog Number 1NO-1NC 5 XTPAXSA11 5 XTPAXSAC

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

XT IEC Power Control Manual Motor Protectors

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

MS25, MST25, MS20, MST20

Electronic overload relays EF205 and EF370

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

AF40... AF96 3-pole contactors Technical data

3 - Protection components Motor circuit-breakers

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

D509E. Manual Motor - Starters

Control Circuit Protection

Industrial Switchgear New Products Catalogue Pole Switching with the DILMP Contactors

Thermal overload relay TF140DU and TF140DU-V1000

Thermal overload relay TF65 and TF96

Series KTU7 UL489 Molded Case Circuit Breakers

Technical data for manual motor starters Type MS325

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Protection components

Bulletin 193-T1 Bimetallic Overload Relays

BETA Switching Switches and Light Indicators

1489-M Circuit Breakers

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

Series KTU7 UL489 Molded Case Circuit Breakers

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Features 1 Phase HP/Volts 1/6 HP AT 230 V 3 Phase HP/Volts 1/2 HP AT 200/230 V, 1-1/2 HP AT 460/575 V

06/001. Overload Relays, Motor-Protective Relays Overview. Overload / Motor-Protective Relays. Moeller HPL /2002

Miniature Circuit Breakers

Manual Motor Starters. Meta-MEC

Thermal Overload Relays

Protection Equipment. 5/2 Introduction

and other modular devices for low voltage installation

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Series L9 UL489 Miniature Circuit Breakers

Manual motor starter MS132

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

Manual motor starter magnetic only MO325

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

IP20 degree of protection; IP40 degree of protection after installation in a distribution box

Selection Guide Motor Control Device Solutions

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF series contactors (9 2650)

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

A302DN.40/.63A Thermal Current Motor Starter

Circuit Breakers BZM. Product Information. Circuit Breaker BZM1 16 to 125 A. Circuit Breaker BZM2 125 to 250A. BZM1 & BZM2 Accessories

max pole for t=15 ms

Manual motor starter MS132

SIRIUS 3RU2 Thermal Overload Relays

Electrical sector solutions E Line family. Industry leading design in a compact package

Manual motor starter MS132

Industrial Contactors CTX 3 3P 185A - 800A

Reduced Voltage Motor Starters

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

IEC Contactors & Starters XT IEC Power Control

Transcription:

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A Partno. PKZM01-4 Articleno. 278482 CatalogNo. XTPB004BC1 Deliveryprogramme Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation Basic function Motor protection Notes Also suitable for motors with efficiency class IE3. IE3-ready devices are identified by the logo on their packaging. Contact sequence Max.motorrating AC-3 220 V 230 V 240 V 380 V 400 V 415 V P kw 0.75 P kw 1.5 440 V P kw 1.5 Settingrange Overload releases I r A 2.5-4 Short-circuit releases max. I rm A 62 Connection technique Screw terminals Notes Accessory Page 3 Standard auxiliary contact 072896 5 Trip-indicating auxiliary contact 072898 6 Shunt release, undervoltage release 073187 phase failure sensitivity to IEC/EN 60947-4-1, VDE 0660 part 102. Can be snap-fitted to IEC/EN 60715 DIN-rail with 7.5 or 15 mm height Technicaldata General Standards IEC/EN 60947, VDE 0660 Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature C Storage ϑ C -40 - +80 Open C - 25-55 Enclosed C - 25-40 02/13/2015 278482 - HPL-ED2014 V9.0 EN 1 / 7

Mounting position Direction of incoming supply as required Degree of protection Device IP20 Terminations IP00 Protection against direct contact Finger and back-of-hand proof Mechanical shock resistance half-sinusoidal shock 10 ms to IEC 60068-2-27 g 25 Altitude m 2000 Terminal capacity screw terminals mm 2 Solid 2 mm 1 x (1-6) 2 x (1-6) Flexible with ferrule to DIN 46228 2 mm 1 x (1-6) 2 x (1-6) Solid or stranded AWG 18-10 Specified tightening torque for terminal screws Main cable Nm 1.7 Control circuit cables Nm 1 Mainconductingpaths Rated impulse withstand voltage U imp V AC 6000 Overvoltage category/pollution degree III/3 Rated operational voltage U e V AC 690 Rated uninterrupted current = rated operational current I u = I e A 16 or current setting of the overcurrent release Rated frequency f Hz 40-60 Rated frequency Hz 40-60 Current heat loss (3 pole at operating temperature) W 6 Lifespan, mechanical Operations x 10 6 0.05 Lifespan, electrical (AC-3 at 400 V) Operations x 10 6 0.05 Maximum operating frequency Ops./h Max. operating frequency Ops/h 25 Short-circuit rating DC Short-circuit rating ka 60 Short-circuit rating 60 Motor switching capacity ka rms AC-3 (up to 690 V) A 16 DC-5 (up to 250 V) A 16 (3 contacts in series) Tripblocks Temperature compensation to IEC/EN 60947, VDE 0660 C - 5 40 Operating range C - 25 55 Temperature compensation residual error for T > 40 C 0.25 %/K Setting range of overload releases x I u 0.6-1 Short-circuit release fixed x I u 15 Fixed short-circuit release Basic device 15.5 x I u Short-circuit release tolerance ± 20% Phase-failure sensitivity IEC/EN 60947-1-1, VDE 0660 Part 102 DatafordesignverificationaccordingtoIEC/EN61439 Technical data for design verification Rated operational current for specified heat dissipation I n A 4 Equipment heat dissipation, current-dependent P vid W 5.33 Heat dissipation capacity P diss W 0 02/13/2015 278482 - HPL-ED2014 V9.0 EN 2 / 7

IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements. 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. TechnicaldataETIM5.0 Low-voltage industrial components (EG000017) / Motor protective circuit-breaker (EC000074) Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kv) / Circuit breaker motor protection (ecl@ss8-27-37-04-01 [AGZ529012]) Setting range overload protector A 2.5-4 Adjustment range undelayed short-circuit release A 62-62 Phase failure sensitive Yes Switch off technique Thermomagnetic Rated operating voltage V 690-690 Rated permanent current Iu A 4 Rated operation power at AC-3, 230 V kw 0.75 Rated operation power at AC-3, 400 V kw 1.5 Connection type main current circuit Screw connection Device construction Built-in device fixed built-in technique With integrated auxiliary switch No With integrated under voltage release No Number of poles 3 Rated short-circuit breaking capacity lcu at 400 V, AC ka 50 Degree of protection (IP) IP20 Approvals Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E36332 UL Category Control No. NLRV CSA File No. 165628 CSA Class No. 3211-05 North America Certification UL listed, CSA certified Specially designed for North America No 02/13/2015 278482 - HPL-ED2014 V9.0 EN 3 / 7

Suitable for Branch circuit: Manual type E if used with terminal, or suitable for group installations Characteristics Motor-protective circuit-breaker tripping characteristic (high-capacity) compact starter, PKZM0- T (not for PKM0- ), PKZM01 02/13/2015 278482 - HPL-ED2014 V9.0 EN 4 / 7

02/13/2015 278482 - HPL-ED2014 V9.0 EN 5 / 7

Let-through characteristics 02/13/2015 278482 - HPL-ED2014 V9.0 EN 6 / 7

Dimensions Additionalproductinformation(links) IL03407010Z(AWA1210-2138)Motor-protectivecircuit-breaker IL03407010Z (AWA1210-2138) Motor-protective circuit-breaker Motor starters and "Special Purpose Ratings" for the North American market Busbar Component Adapters for modern Industrial control panels ftp://ftp.moeller.net/documentation/awa_instructions/il03407010z2014_02.pdf http://www.moeller.net/binary/ver_techpapers/ver953en.pdf http://www.moeller.net/binary/ver_techpapers/ver960en.pdf 02/13/2015 Eaton Industries GmbH http://www.eaton.eu 12/2014 by Eaton Industries GmbH 278482 - HPL-ED2014 V9.0 EN 7 / 7