DLTC. lighting controls. transfer circuit for use with low-voltage down-lighting. features

Similar documents
Lumencia. LLMPS SERIES Micro Power Systems. Multi-Unit Residential Lighting. Job Name: Type:

RELIABILITY THROUGH TECHNOLOGY

INTRODUCING THE NEW MINI INVERTERS BY READY-LITE

CODE MANDATED INTERIOR EMERGENCY LIGHTING:

STL. Series. Emergency Lighting Inverter 3kW to 160kW Central System

systems Systems Emergency Lighting Inverter 120 or 277V 60 Hz Power

BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination

GLX. Series. 1kW to 16kW Central System

BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination

UV16 vandal resistant, wet/damp location emergency lighting

BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST

Model #: APS V DC or 120V AC input; 120V AC output (hardwired) Auto Transfer Switching option for battery backup / UPS operation

ILLUMINATOR LV. Emergency Lighting Inverter System 175VA through 750VA. Illuminator Series LV Single Phase

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP038A0712

FLUORESCENT EMERGENCY BALLAST Lumens. When using this lighting device safety precautions should be followed at all times

3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

LUMENTON. including poured concrete. Suitable for installation within 4 feet of ground. Product specifications subject to change without notice.

General Purpose Buck - Boost Wiring Diagrams... 86

LiteMinder. LM Series Inverter Pure Sine Wave Modular Inverter Technology. Fast Transfer System 1.0 to 18.75KVA LED Compatible

A R C H I T E C T U R A L WA L L L U M I N A I R E S E R I E S

A R C H I T E C T U R A L LO W L E V E L F LO O D L I G H T S E R I E S

OUTPUT CONNECTIONS Bring the wires of the light fixture through the other open knockout and connect them to the power supply output wires.

Model #: RV1012ULHW. 12V DC or 120V AC input; 120V AC output (hardwired)

BAL3000 BAL3000. Fluorescent Emergency Ballast Lumens. Specification Sheet. Emergency Ballast 1/19/2012. Project: Catalog#: Approved by:

Installation And Operation Instructions For FHSCP-UNV Series Emergency LED Drivers Models: FHSCP-UNV-5WL, 7.8WL, 10.7WL, 13.

UL AND CODE COMPLIANCE

Planning Low Voltage Layouts

1250W 12VDC PowerVerter Ambulance/EMS Inverter/Charger with 2 Hospital Grade Outlets

3000W PowerVerter RV Inverter/Charger with Hardwire Input/Output

KT-EMRG-1400-SL /B. 3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

CEPS Series UL924 Emergency Lighting Inverters

Model #: APS3636VR. 36V DC or 120V AC input; 120V AC output (hardwired)

Micro Lighting Inverter

New dimming drivers are compatible with most wall dimmers for % light control. For non-dimming

IMPORTANT SAFEGUARDS

Low Voltage Lighting Power Supplies

131 1 x 4. Lensed Static Troffer, Grid Mount FEATURES & SPECIFICATIONS ORDERING INFORMATION

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

Industrial & Harsh Environment - Battery Units

Low profile frame is just 0.5" thick CONFIGURATIONS

Nova UAC (NV-UAC-M) Modified Sine Wave 650W 800W 1000W

Emergency Lighting Phantom PM Series...4, M Series...6 RSQ Series...7 RD Series...8, 9 TBR Series...10, 11 MG Series...

EON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 10KW 33KW Systems

3000W PowerVerter RV Inverter/Charger with Hardwire Input/Output

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

750W PowerVerter RV Inverter/Charger with Hardwire Input/Output

131 1 x 4. Lensed Static Troffer, Grid Mount FEATURES & SPECIFICATIONS ORDERING INFORMATION

NT-300 Series Single Circuit Track System & Accessories

NMF 2 SERIES Non-Metallic Enclosed and Gasketed Fluorescent Lighting for Wet and Damp Locations

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

Uninterruptible Power Supplies

PowerVerter 750W RV Inverter/Charger with Hardwire Input/Output

exit signs solid state lighting emergency lighting wayfinding signage ballasts & controls central systems

Apollo 8. lamping. patient bed pair example. 8" wide recessed patient bed light with exam function available in 2', 3' & 4' lengths.

Self-Testing Industrial Series

3 Uninterruptible Power Systems

FV Series Nonmetallic Fluorescent Luminaires For Hazardous and Adverse Locations

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

EON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 40KW 55KW Systems

2 Uninterruptible Power Systems

621 Recessed LED Downlights - 2

style with efficiency

LIGHT COLUMN PEDESTRIAN

LIGHTPLANE 1 RECESSED - LP1R

The Tracking Magnet Surface High-tech LED lighting system for interior architecture

Avenue A. Grid Mount. Drywall Flange. lens. Narrow aperture high performance T5/T5HO asymmetric wall wash.

Renewable Energy Product & Parts Catalog

Avenue A. Grid Mount. Drywall Flange. lens. Narrow aperture high performance T5/T5HO asymmetric wall wash.

Installation & User Instructions

Project. Comments. Prepared by

3 Uninterruptible Power Systems

LP Dimming Panels. GRAFIK Systems

Centera LED Fully Luminous 2x2

SURE-LITES FBP140XLP Instruction Manual

Seem 6. Narrow 6 aperture slot fluorescent luminaire that integrates with the ceiling for a clean unobtrusive aesthetic.

Illuminator Series CR NEMA 3R

Spectron Industrial Series

MODEL NUMBER: APS2448UL

Lighting Systems Argus-7

OEM Emergency Portfolio. Product Guide. Emergency components for LED, fluorescent and auxiliary purpose

Fixed Head Emergency Lights

SPECIFICATION SHEET :FH6-DUAL-3000L. Project Type Model # Remarks

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE LMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

622 Recessed LED Wallwash - 4

621 Recessed LED Downlight - 6

220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount

EMEX. Central Battery Systems Emergency Lighting

Recessed. EvoKit LED Retrofit Kits Gen 3

610 Recessed LED OpticLites

Uninterruptible Power Systems

CFL-LED-KIT Compact FloodLight, LED 2.0 Upgrade Kit kl_cfl_ledkit_spec.pdf

technology mvjvi cwi vi Av jv cwiqbœ Rxeb

LIGHT COLUMN PEDESTRIAN TECH BRIEF

LEN Series 2x2 / 2x4 LED

Avenue B. Grid Mount (Regress Trim Shown) Flush Lens. Drywall Flange (Regress Trim Shown) Narrow 3" slot LED with frosted satin lens.

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Minimum operation time is 1,000 hours annually. Equipment is listed on the DLC QPL. Minimum operation time is 1,000 hours annually

3 Uninterruptible Power Systems

Transcription:

LT transfer circuit for use with low-voltage down-lighting Two channel device providing switching for up to 75 watts per channel ombines existing low-voltage lighting with a 12 volt emergency unit power pack, such as LightGuard's LPM (sold separately) Transfer function occurs independent of wall switch position uring utility power failure, LT allows the 12 volt emergency power unit to supply power directly to the lamps of the low voltage lighting fixture Housing and cover are constructed of 20 gauge galvanized steel Listed for insulated ceiling systems (I rated) amp Location listed ETL listed to UL 924 standards Input: 12 VA, 0.72 watts Output: 12 V, 2 channels at 75 watts maximum each amp Location: 32 F (0 ) to 122 F (50 ) Three years full 5.5 (13.97 cm) 1.3 (3.27 cm) Typical Single Lamp Wiring iagram Low Voltage Transfer Module observe proper polarity 2.73 (6.9 cm) Xfmr 1 A1 A1 A2 A2 XFMR 1 XFMR 2 LAMP O L1 L1 L2 L2 L- L+ EMERGEY POWER IPUT 12 V Emergency Unit Equipment supplied separately Lamp 1 LT LT = own-lighting Transfer ircuit Lighting Fixture Xfmr 1 indicates original wiring path Lamp 1 12V 75W max. 68

FLT fluorescent lighting transfer circuit that is generator or inverter compatible 120/277 VA, 60 Hz dual voltage input with all inputs fused to 3 amps Transfers generator or A systems power to A fluorescent lighting ballasts in the event of a utility power failure Transfer function occurs independent of wall switch position One FLT device is required per lighting fixture Suitable for use in sealed and gasketed luminaires Housing and cover constructed of 24 gauge galvanized steel Low-profile housing allows mounting in most low profile fluorescent fixtures with low-profile A ballast Wire end caps provided UL 924 listed, UL amp Location listing FPA 101, E, BOA, OSHA and IB illumination standards Input power requirements: 0.27 ma (120/277 VA), 1.48 watts amp Location: 32 F (0 ) to 131 F (55 ) Five years full 1.1 (2.79 cm) 1.17 (2.97 cm) Typical Wiring iagram (shown with utility power present) ormal Power ist. Panel Wall Switch Blue Auxiliary Power Transfer Unit Utility Power Orange Black White 277V 120V ontrol Module Transfer Switch Red Brown A Ballast Auxiliary Power Emer. Power ist. Panel White/Red Wht/Blk FLT FLT = Fluorescent Lighting Transfer ircuit 69

entaurus Linebacker 100 or 250 watt interruptible power supply for emergency lighting applications 120 or 277 VA, 60 Hz dual voltage input and output Maintenance-free, sealed lead calcium batteries, minimum 90 minutes of emergency operation, 91% nominal lumen output from luminaire Square wave output, completely solid-state inverter, low-voltage disconnect, brownout protection is 75% of nominal line voltage, overload, and short circuit protection ormally on and/or normally off loads, variable rate, fully automatic, temperature compensated charger Operates incandescent, fluorescent, and LE lighting loads and is compatible with dimming ballasts EMA 1 enclosure, heavy duty steel cabinet with with multiple conduit entries Surface, recess, and ceiling grid mounting options UL 924 listed, meets FPA 101, E, BOA, OSHA and state and local codes, optional self-diagnostics Input Power Requirements 100 Watt Models: 0.198 A (120 VA), 0.080 A (277 VA) 250 Watt Models: 0.570 A (120 VA), 0.268 A (277 VA) 68 F (20 ) to 86 F (30 ) Surface Model - 100 W A knockout Recessed Model 20.5 (52.07 cm) LB LB = entaurus Linebacker AESSORIES (Ordered Separately) LBRT = Remote Test Switch 10.5 (26.67 cm) 0.625 (1.58 cm) B knockout 4.25 (10.79 cm) 5.5 (13.97 cm) OUTPUT WATTAGE 100 = 100 Watts 250 = 250 Watts* *Available in surface mount only. 9.5 (24.13 cm) Surface Model - 250 W A 18.5 (46.99 cm) T-slot mounting holes (4 sides) 6.0 (15.24 cm) (4 sides) MOUTIG OFIGURATIO T = eiling Installation S = Surface Wall Mount R = Recessed Wall Mount B eiling Model 4.25 (10.79 cm) 0.625 (1.58 cm) 7.0 (17.78 cm) (both ends) 5.75 (14.6 cm) OPTIOS OT = Self-iagnostics T1= 120V 15 Minute Time elay T2= 277V 15 Minute Time elay SP = Special Paint (consult factory) Model 100 W 250 W A 18.625 18.625 B 9.625 10.125 25.375 (64.45 cm) 23.75 (60.32 cm) 4.375 8.25 14.5 13.0 0.75 (1.9 cm) 6.75 (17.14 cm) 70

entaurus Linebacker 300 to 600 watt fast transfer power supply for emergency lighting applications 120 or 277 VA, 60 Hz dual voltage input and output Maintenance-free, sealed lead calcium batteries, minimum 90 minutes of emergency operation, pulse width modulated design (PWM), 98% throughput efficiency Input circuit breaker, solid state PWM inverter with sine wave output, output fusing standard, output circuit breakers optional Low-voltage disconnect, fully automatic, temperature compensated, solid-state charging system Operates incandescent, electronic ballast loads, HI, and LE lighting loads as well as critical loads requiring conditioned emergency power EMA 1 enclosure, durable powder coat finish with multiple conduit entries UL 924 listed, meets FPA 101, E, BOA, OSHA and state and local codes 68 F (20 ) to 85 F (30 ) 300 W, 400 W 600 W 16.0 (40.64 cm) 23.0 (58.42 cm) LB 22.0 (55.88 cm) LB = entaurus Linebacker OUTPUT WATTAGE 300 = 330 VA / 300 Watts 400 = 660 VA / 400 Watts 600 = 660 VA / 600 Watts VOLTAGE OFIG. 120 = 120V 277 = 277V 22.0 (55.88 cm) FATORY ISTALLE OPTIOAL IRUIT BREAKER OUTPUT IRUIT BREAKERS 1 = OB1 2 = OB2 OUTPUT IRUIT BREAKER VOLTAGE* A = 120 VA R = 277 VA * Output circuit breaker voltage must match the system input voltage. OUTPUT IRUIT BREAKER RATIG 10 = 10 Amps 15 = 15 Amps 20 = 20 Amps 71

ightwatch Power Supply system for low-voltage normal and emergency power Provides continuous low-voltage normal power and emergency power to support 12 VA ightwatch luminaires Maintenance-free, sealed lead calcium battery Electronics consists of three sections to include a fully automatic battery charging system, output transformer and a power failure sensing control circuit that automatically routes battery power to ightwatch luminaires in the event of a power failure onstructed of 18 gauge die-formed steel and has an easily removable front cover Top and side conveniently located to route output circuits or to hardwire the input power esigned for wall mounting and is provided with keyhole slots on the back for ease of installation Provided with two pre-wired, three foot cord and plug sets ETL listed to UL 924 standards Input: 120 VA, 60 Hz, 1.9 A ormal Output: 12 VA, 60 Hz, 150 VA/150 W Emergency Output: 12 V, 150 W via two 75 W circuits 65 F (19 ) to 85 F (30 ) Front View 17.5 Side View (44.45 cm) 5.0 (12.7 cm) 10.8 (27.43 cm) 0.5 (1.27 cm) (both sides) Back View 16.0 (40.64 cm) Top View Keyhole Openings for Mounting 0.5 WPS1 WPS1= ightwatch Power System 72