HD Insert Series. Application Specification Apr 30 th, 2017 Rev. A. Table of contents

Similar documents
HDD Insert Series. Application Specification Apr 30 th, 2017 Rev. A. Table of contents

Commercial MATE-N-LOK* Pin and Socket Contacts

Power Double Lock Connector System

3.18-mm [.125-in.] POWERBAND* Contacts

Coaxial Snap-Lock Connectors

HB IP65 Hood and Housing Series

JUL 14 Rev B

Application Specification Pin&3Pin Miniature waterproof connector 28July2016 REV: C

Standard Timer Connectors

POWER TRIPLE LOCK* Connector System

FASTON* 110 Series. Receptacle With F Crimp Insulation Support Barrel. Wire Barrel. Insulation Support Barrel. Figure 1

AMPSEAL 16* Connector System 24 JUN 13 Rev C

FAKRA-Comliant SMB 50-Ohm Inline Connectors 27 JUN 11 Rev E

PLASTI-GRIP* Terminals and Splices

FAKRA Automated In-Line Connector System

FASTON* High Temperature Tab Terminals

Series 110 MK III, Series 187 MK II and MK III, Series 250 MK II, MK III, and RAST 5 & 7

AMPLIMITE* HDP- 20 and Economy

8-Position Cat5E EMT Shielded Slim-Line Modular Plug

FAKRA-Compliant SMB Gen-4 Connector System

Position Cat6 Shielded. Modular Plug Connectors. Application Specification

Economy Power (EP) 2.5 Contacts; Plug and Receptacle Housings; and Vertical and Right-Angle Headers

Application Specification

APPLICATION SPECIFICATION

Universal MATE-N-LOK* Connectors

Product Specifications (for connectors) and (for headers), provides product performance requirements and test result information.

VAL-U-LOK* Series Headers, Connectors, and TPA Accessories

HK-003,HC SERIES HK-003 HCSERIES. Modular Heavy-current connector WAIN 12-01

Plug (male) Jack (female) Interface dimensions conformable to the standards: min. max. min. max. A B C D E H I

Han K 3/0, K 3/2 / Han HC Modular. Contents Technical characteristics Han K 3/0, Han K 3/ Inserts Han K 3/0, Han K 3/

Component Specification

MMC RTX series EN3716

Application Specification.062 Diameter Pin and Socket Contacts and Housings 21 MAR 11 Rev E

EPIC. Connector Accessories CONNECTOR ACCESSORIES. Glands, Seal Rings & Adapters Glands 412 EPIC SM & SP Glands, EPIC CM-M Glands

TIDALFLUX 2300 F Quick Start

Application Specification Circular Plastic Connector (CPC) Series 45 System 05 AUG 14 Rev D

Han-Power Energy Bus Components

Installation Manual. Installation Manual. AXITEC, LLC 160 Greentree Drive, Suite 101 Dover, Delaware

Crimpmate Range pitch 5.00

11DIA SQUIB CONNECTOR COMPACT TYPE

Fused Disconnect Terminal Blocks for Miniature Fuses with CAGE CLAMP connection, Series

RoHS 2011/65/EU ISO 9001 ISO BS OHSAS 18001:2007 GREEN ELECTRONICS CCF. Connectors

Product Manual. Installation Instructions for CHSM-230M Series Solar Module

General characteristics and technical data Series MCS

HVP deg 1pos Plug&Header Connector Assy APPLICATION SPECIFICATION

ASSEMBLY INSTRUCTIONS ZONE MODULE 2 1 THERMOSTAT DESCRIPTION POWER SUPPLY AIRZONE CONTROLLER

FISCHER FREEDOM TM SERIES

General notes. Operating conditions

Underground Bus Bar Distribution System 03 SEP 13 Rev B

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc.

Micro MATE N LOK* Connectors

Unimate Range Pitch 5.08

K CHAPTER FREEDOM TM SERIES EASY MATING EASY CLEANING EASY INTEGRATION FISCHER KEY FEATURES

Ø1,5mm System Rev G EC: EGA

2M Series Contacts and Tools

ENERGY. TECWATER EMV-FC S1BC4N8-F 0,6/1 kv. Screened Cable for Water Application

Powermate Range pitch 7.00 Powermate Range pitch 7.00

Operating Instructions (Translation)

Assembly Instruction. EL OCHITO BLUE CONTACTS SuperSpeed USB TYPE I: PIN /SKT CABLE:

HL (AZH) LIMIT SWITCHES

94 Series - Socket overview for 55 series relays

Coupling ring, screw thread provides secure cable coupling. Shielded Cat 5e coupler maintains screening. Retaining Nut

A-M COPPER TUBE CRIMPING LUGS. for copper conductors. A-M series lugs are manufactured

NTRAK Alternate Wiring and Connectors - Quick Reference - Doug Stuard, NVNTRAK

web:

T2 Terminator Tooling Specification Sheet Part No

HANDLING OF ASSEMBLY... 1 RRH END OF ASSEMBLY... 1 BASE STATION END OF ASSEMBLY... 7 POWER CODING REVISION HISTORY... 11

PRODUCT INFORMATION. ÖLFLEX HEAT 180 SiF

Emotron FDU and VFX 2.0

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 High voltage contacts Quick and easy assembling Protection class IP68 acc.

General characteristics

CERTAIN 2005 MODEL YEAR FIVE HUNDRED, MONTEGO AND CERTAIN 2005 AND 2006 MODEL YEAR FREESTYLE VEHICLES DOOR LATCH WATER PROTECTION

(K),(M),(P)489TB/G Up to 42 kv

TEBS: Details for Installation / Storage / Maintenance

Engineered installation products Solutions for control panel applications

PRODUCT INFORMATION H07V-K

INSTALLATION MANUAL

Installation Manual AXITEC SOLAR MODULES

PCB plug-in connectors

LANCER FOG LAMP KIT MZ380479EX (for RHD) INSTALLATION AND HANDLING INSTRUCTIONS

Installing and Removing Power Supplies

Directory chapter 08. InduCom Robust and EMI protected D-Sub interfaces

2.5mm Pitch Connector for Full Lock and Discrete Wire Connection

06. har-mik INTERFACE CONNECTORS

GMT Fuse Panel Installation Guide

... A Vital Part of Connection World CMPTER. Cable Connectors PCB Connectors Assembly Instructions Mounting Holes MCX CONNECTORS

DIVISION 16 - ELECTRICAL SECTION 16xx0 MANUFACTURED WIRING SYSTEM ACCESS FLOOR

INSTALLATION MANUAL CRYSTALLINE SOLAR MODULES

D-subminiature Backshells - Two-Piece D*H Series

#GL18006-L2 Honda Gold Wing 1800 & F6B models - All Years Lower Cowl LED Driving Lights INSTALLATION INSTRUCTIONS

HL (AZH) Limit Switches

(K),(M)430TB/G Up to 36 kv

ELECTRICAL CONNECTORS B.1

PRODUCT SPECIFICATION STANDARD TIMER CONNECTOR, RAST 5mm, 2-12 POSITIONS

onlinecomponents.com

MULTICONTACT. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates

Series BHT. Specifications. B HT 6 pole + PE. B HT 10 pole + PE. B HT 16 pole + PE. B HT 24 pole + PE. Page

Female socket block, Screw connection, No. of poles: 12, Width: mm, Colour: Green

2.5mm Pitch Connector for Full Lock and Discrete Wire Connection

Put the battery pack in place. The lowest cable from the battery pack goes to the Predator Divecan. The middle cable will go to the inhale lung.

Transcription:

HD Insert Series Table of contents 1. INTRODUCTION... 2 2. SUPPORTING DOCUMENTS... 2 2.1. Customer drawings... 2 2.2. Product specification... 2 2.3. Application Specification... 2 2.4. Standards... 2 3. DESCRPTION... 3 4. REQUIREMENTS... 4 4.1. Wire selection and preparation... 4 4.1.1. Stripping length L... 4 4.1.2. Insulation diameter... 4 4.2. Assemble wires to inserts... 5 4.2.1. Inserts of crimp termination... 5 4.3. Cable length inside the housing... 8 5. ASSEMBLY... 9 5.1. Contact inserts... 9 5.2. Grounding... 11 5.3. Marking... 12 5.4. Polarization function... 12 6. STORAGE... 13 6.1. Chemical exposure... 13 6.2. Storage condition... 13 This specification is a controlled document 1 of 13

1. INTRODUCTION This specification contains the regulations for assembly of HD contact inserts and the handling of these inserts. 2. SUPPORTING DOCUMENTS 2.1. Customer drawings Please refer to the customer drawings of HD insert series. 2.2. Product specification The product specifications of the used articles are to be taken into account. The product specification describes the technical data as e.g. regulations, approvals, temperature range and rated voltage. For further reference refer Product spec. 108-137042. 2.3. Application Specification Connectors shall be assembled as below mentioned application specifications to ensure correct connector assembly. 2.4. Standards EN 61984: Connectors - Safety requirements and tests IEC 60664-1: Insulation coordination for equipment within low-voltage systems (Part 1) IEC 60999-1: Electrical copper conductors- Safety requirements for the clamping units for conductors This specification is a controlled document 2 of 13

3. DESCRPTION This application specification describes the HD male insert and the female insert. The listed terms are used in the specification as below shown HD-040. Pin crimp contact, need order separately Male insert Grounding terminal Fixing screw Female insert Socket crimp contact, need order separately HD-040 for reference This specification is a controlled document 3 of 13

4. REQUIREMENTS 4.1. Wire selection and preparation 4.1.1. Stripping length L Use proper tooling to strip the wire. Figure 1 When stripping the wire, care must be taken to avoid scraping, nicking, or cutting the conductor. Care must also be used when handling the wire during stripping to prevent cracking or breaking the conductor and insulation. Depending upon the cross section of the wire or cable, the stripping length has to be selected from the table below. See Table 1. Table 1 Contact Insert Max. Wire cross section Strip Length For Reference Current [mm 2 ] AWG L [mm] HD 2.5 mm² 14 6 10A 4.1.2. Insulation diameter Any wire that is used for the Electrical purpose is covered with insulating polymer. This insulation on the wires depends upon the wire size and type of application where it is being used. The insulation diameter for various wire sizes is as shown in table 2 only for reference. This specification is a controlled document 4 of 13

Table 2 Max. Wire cross section Insulation Diameter [mm 2 ] AWG in (mm) 2.5 mm² 14 3.8 MAX. The Insulation diameter over the wire specified in the table 2 is for the insulation concentric, with equal thickness layer over the conducting wire. 4.2. Assemble wires to inserts 4.2.1. Inserts of crimp termination a. Assemble stripped wires to contacts (Crimp) Crimping tool Crimping tool is available as below Figure 2 &3: Wire range: 26AWG ~ 12AWG ( 0.14 mm 2 ~ 4.0 mm 2 ) Type: RPC-M23-T-B (For DD contact) Order number: T3100000022-000 Figure 2 This specification is a controlled document 5 of 13

Wire range: 26AWG ~ 12AWG ( 0.14 mm 2 ~ 4.0 mm 2 ) Type: CRIMPBOX-0.5/4 (For MM contact, 1.0/1.5/2.5 mm 2 ) Order number: T3100000001-000 Figure 3 Crimp Insert the cable - stripped according to Table 1 - into the wire barrel of the contact. The wire strands must be visible in the reference hole of the contact. Afterwards, crimp the contact in the crimp area, using the correct tool for this type of contact. During the termination process make sure that the contact in the contact zone is not damaged or deformed. When using manual crimp tools the following points must be followed: 1). Equip manual crimp tool with the correct locator or positioning ferrule. 2). When using different manual crimping tools the pliers have to be adjusted by plug gauge to fit the crimp area. 3). Fully insert contacts into the locator. 4). Clamp the wire with help of crimp tool. Note that to press the crimp tool till the stopper is reached a positive crimp. This specification is a controlled document 6 of 13

Crimp DD contact as below : Figure 4 For more detailed information, please refer to related contacts application specifications. b. Insert crimped terminals into inserts The crimped terminals are plugged into the insert by gently pushing it into the required position until the contact is locked by the inserts, a click should be heard normally. This specification is a controlled document 7 of 13

Figure 5 4.3. Cable length inside the housing For the optimal cable lay inside the housing it is necessary to make sure that the striped length is fit to used cable type; is fit to permitted bending radius of the cable and make sure that the contact insert is fit to the type of hood. For recommended cable lengths (cable entry: TOP, SIDE), please refer to the Table 3. In accordance with the application it is proposed the cable length is selective to shorten (e.g., shorter cable near the cable gland longer cable at the turned off side). Top entry cable Side entry cable Figure 6 This specification is a controlled document 8 of 13

Table 3 Insert size HD-007 HD-008 Hood Size H3A Type of hood Top entry cable Cable length (mm) Side entry cable H3A 35 35 For reference only H3APR 35 35 For reference only HD-015 H10A H10A 40 47 For reference only HD-025 HD-040 HD-064 H16A H16B H24B H16A 40 55 For reference only H16A(High structure) 50 47 For reference only HBPR(Central locking) 96 110 For reference only HBPR(Opposite angle locking) 111 125 For reference only HB 76 90 For reference only HB(High structure) 86 100 For reference only HBPR(Central locking) 113 123 For reference only HBPR(Opposite angle locking) 128 138 For reference only HB 93 103 For reference only HB(High structure) 103 113 For reference only Note 5. ASSEMBLY Assembling the contact inserts for both Male & Female connector has to be carried out with proper tools. 5.1. Contact inserts The contact inserts are screwed into a corresponding hood or housing by fixing screws M3. The torque is 0.5Nm for reference. Note: * The distance for safe contact of the contact inserts is max. 21mm. As shown Figure 7. Fixing screw(torque 0.5Nm) 19.5* Figure 7 This specification is a controlled document 9 of 13

Information for panel cut-out: Application Specification 114-137042 Information concerning the panel cut-out for assembly of the contact inserts without housings can be taken from the customer drawings. Panel cut-out as below shown. No panel cut-out dimension for HD-007/HD-008 For HD-007/HD-008, assemble with H3A hood and housing directly. No panel requirement. Panel cut-out dimension for HD-015/ HD-025/ HD-040/ HD-064 Panel cut-out dimension for HD-050/ HD-080/ HD-128 This specification is a controlled document 10 of 13

Table 4 Insert Type. Dimension (mm) A B C D E F G HD-015 43.5 16 32 49.5 10 3 - HD-025 60 16 32 66 10 3 - HD-050(2x 25) 60 16 56 66 10 3 24 HD-040 68.5 27 36 77.5 18 7.75 - HD-064 95 27 36 104 18 7.75 - HD-080(2x 40) 68.5 27 71 77.5 18 7.75 35 HD-128(2x 64) 95 27 71 104 18 7.75 35 5.2. Grounding Fixed to the contact inserts are grounding contacts, on which with the grounding screw (M4). The cable can be locked on the earth potential. The grounding contact in an assembly is the only part that will be having press contact with corresponding grounding contact on the other assembly near the interfacing portion of the housings. Grounding contact male Screw M4 Grounding contact female Screw M4 Figure 8 This specification is a controlled document 11 of 13

This clamping point is suitable for connection of a cable with a nominal cross section of up to 4 mm². It is recommended to use cables with insulated barrels. The stripped end of the cable has to be put under the clip tab. Earthing is to be executed according to IEC 61984. Tighten torque 1.2Nm. 5.3. Marking The connector type, rating and the number of position etc. refer to the corresponding HD insert customer drawings. 5.4. Polarization function The process of assembling the male and female inserts without any mismatch and difficulty calls for polarization. This is done with the help of ribs or slots and which are present on both the male insert as well as the female insert. As shown in Figure 9. Ribs Slots Figure 9 This specification is a controlled document 12 of 13

6. STORAGE 6.1. Chemical exposure Do not store the connectors near any chemical listed below as they may cause corrosion stress the connector contacts: Alkalies, Ammonia, Citrates, Phosphates, Citrates, Sulfur, Amines, Carbonates, Nitrites, Sulfides, Nitrites, Tart rates. 6.2. Storage condition The connectors should be stored in the air ventilation, no corrosive gas, no rain and no snow in the warehouse. Relative humidity: less than 85% RH. The connectors should remain in the shipping containers until ready for use to prevent deformation to the contacts. The connectors should be used on a first in, first out basis to avoid storage contamination that could adversely affect electrical functions. --------------------------------------------------------END------------------------------------------------------------ This specification is a controlled document 13 of 13