ELE-CMS-E-2007 Electrical Project Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS

Similar documents
ELE-CMOS-E-2004 Electrical Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS

ELE-MPT-E-2009 Senior Maintenance & Protection Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS

ELE-MOS-E-2006 Electrical Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS

ELE-CMS-E-2001 Electrical Manager PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS

78-EL-CS-E-1994 Senior Electrical Engineer. PERSONAL DATA Nationality : Egyptian

ELE-OS-E-2002 Start-up Shift Operation Engineer & Permit Coordinator PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS

ELE-CMOS-E-2001 Manager of Electrical Construction Dept. PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS

ELE-CDGPS-E-1980 Senior Electrical Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS

ELE-PT-E-2005 Electrical Testing & Protection Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS

ELE-PT-E-2003 Senior Electrical Protection & Commissioning Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS

ELE-CMOS-E-1987 Electrical Construction & Maintenance Manager PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS

Approximately 13 years experience in H.V and L.V projects, 9 years in Egypt and two years in Emirates and two year in SAUDI ARABIA

Holds a B. Sc. in Communication Engineering and has about 21 years experience in testing and protection of several substations.

: Nubaria Module III - Egypt (2x250MW GE gas turbines frame 9 FA)

ICX-CMOS-S-2004 Senior I&C Technician PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS

ELE-COS-E-1986 Electrical Lead Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS

B. Sc., Mechanical power science Engineering, May 1987, Monofia University. - Construction Safety Health 30 hours Administration Training by (OSHA).

ASEC scope of work and services can be classified as

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

In any of the 5 star hotels. The exact venue will be informed once finalized.

CURRICULUM VITAE. Having an experience and knowledge in Testing, Commissioning and Maintenance of power plant, substation and process plant.

MEC-CM-E-2001 Lead Mechanical Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS

ELE-MPT-E-2007 Protection, Testing & Commissioning Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

School of Electrical and Information Engineering. ELEC High Voltage. University of Sydney. Dr Keith Mitchell. Engineering

Modular Standardized Electrical and Control Solutions for Fast Track Projects

NEPAL ELECTRICITY AUTHORITY (A Government of Nepal Undertaking)

ELECTRICAL EQUIPMENT : TRANSFORMERS, INVERTERS, RECTIFIERS, UNINTERRUPTABLE POWER SYSTEMS, GENERATORS. UAE, Sharjah, Copthorne Hotel Sharjah

INESING srl. MOBILE SUBSTATIONS Energy Solution. Energy Innovation. INESING srl Energy Innovation

RAPTOR DEFAULT TEST TEMPLATES

MESG 12 / 17.5 / 24 / 36 KV

CHAPTER 4 PROTECTION REQUIREMENTS

Power Products Division. Power Services Service underpins everything we do

93 MWe natural gas fired Combined Cycle Power Plant

University of Houston Master Construction Specifications Insert Project Name

MX431 Generator Automatic Voltage Regulator Operation Manual

KONČAR Group. Research and Development

Aswan high dam - Distributed control system AUTOMATION

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Switchgear and Distribution Systems for Engineers and Technicians

EE042: Practical Power System Protection for Engineers & Technicians

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)

PRACTICAL TROUBLESHOOTING OF ELECTRICAL EQUIPMENT & CONTROL SYSTEMS

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

ICX-CMOS-E-2000 Lead I&C System Engineer(Comm./ GT Controller) PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS

ABB Switzerland Ltd High Voltage Products PTHG-V / Marta Lacorte Business Development LAM High Current Systems. Generator Circuit- Breaker Systems

BHARAT HEAVY ELECTRICALS LIMITED, JHANSI

This tender addendum and clarification forms part of the Request for Proposal and Contract documents, and modifies them as follows:

ADVISE DESIGN IMPLEMENT FOR ELECTROTECHNICAL EXCELLENCE

Air-insulated switchgear UniGear type ZS1

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

Vacuum Generator Circuit Breaker - A trend-setting power plant technology

Package Price for Grid Connected 3.3 MW Synchronized Electricity: Please Call For Details Price

1x New Siemens SGT MW 50 / 60Hz (DF) Gas Turbine Mobile Generator Set

Course Semester Subject Code Subject Name B.E EEE(M) V UAEE507 MARINE ELECTRICAL TECHNOLOGY UNIT-I

Static frequency converter couples US paper mill s 25-Hz and 60-Hz electricity grids

NEXT STEP B) SAFETY :

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

Date Issued: 10 August 2009 Status: ISSUED Review Date: 10 August 2011 Ref: NS5.3 DISTRIBUTED GENERATION TECHNICAL REQUIREMENTS TABLE OF CONTENTS

Operation and maintenance of 11kV, 33kV and 220 kv Substation.

Pankaj Khali, ABB India Limited Representing :ABB Switzerland limited, September 2016 Generator Circuit-Breakers. Technical Seminar: PLN

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Circuit Breaker Prepared By :

Question Set(2017) Switch Gear & protection(5 th SEm) 9. Explain the construction and operating principle with proper diagram:

COMPACT SUBSTATION GUIDE

Service and Rehabilitation Electrical Power Systems

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

MCset kv Medium voltage equipment

TECHNICAL SPECIFICATIONS OF PCC PANEL

2 Unit Petrol Engine Spare parts kits for 4 WD Nissan Patrol

Surabaya Seminar Ferdinand Sibarani, Surabaya, 30 th October Power Quality

SECTION V SWITCHBOARD I 4 Engine/Gen Control Cubicles II 1 Synchronizing System III 1 Ground Detection Network IV 1 600V Feeder Section V 2

Legal Name of the Customer (or, if an individual, individual's name): Name: Contact Person: Mailing Address: Physical Address: City: State: Zip Code:

Electrical Systems - Course 135 COMPOSITE ELECTRICAL PROTECTIVE SCHEMES: PART II

Package Price for Grid Connected 6.0 MW Synchronized Electricity: Please Call For Details Price

Basics of Medium Voltage Motor Control Starter Power Components & Starter Types

34 th Hands-On Relay School

production program 1

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

EMPAC Metal enclosed capacitor bank for wind applications

2006 IEEE PES General Meeting June 2006, Montreal, Canada Paper 06GM0613. Fault Current Limiters - Report on the Activities of Cigre WG A3.

Custom Medium and LV Switchgear 5-38kV Switchgear Power Systems

Chapter 6 Generator-Voltage System

Extracting Valuable Information from HV Circuit Breaker Testing. Charles Sweetser - OMICRON MIPSYCON 2014

MOBILE SUBSTATION GUIDE

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements

Gas Insulated Metal-clad Switchgear, HMGS!

Advanced Protective Relay Training

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

ICX-CMOS-E-2004 Senior I&C Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS

Annex A-4 DIESEL UNITS INDEX TO SYSTEM/COMPONENT CAUSE CODES BALANCE OF PLANT GENERATOR DIESEL ENGINE

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Double earth fault in a PSP during back to back launching sequence

T5S4P3 Synchronous Condensers Application. Mr. Marco Schenone Mr. Sandro Tuscano Mr. Alessandro Oldrati

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

Time Delay Technique for Pinpointing PD Noise on Combined Cycle Systems Troy Coleman, Plant Technical Services

Technical data sheets

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

Title Electrical Technical Maintenance Coding System. Reference Number PMP 01 (RIC Standard: EP SP)

Transcription:

103313-ELE-CMS-E-2007 Electrical Project Engineer Holds a B. Sc. in Electrical Power & Machines Engineering and has about 10 years hands-on experience working in construction, commissioning and maintenance. PERSONAL DATA Nationality : Egyptian Birth Date : 09/11/1985 Gender : Male Marital Status : Married Residence : Currently KSA EDUCATION : B. Sc. in Electrical Power & Machines Engineering, Tanta University, 2007 LANGUAGES Arabic English : Native Language : Very Good COMPUTER SKILLS : Windows, MS Office, Internet TRAINING COURSES AND CERTIFICATIONS : On-shore training at GE for ex2100e generator control maintenance. : On-shore training for Siemens protection relays. : On-shore training for Schneider MV switchgear (mc set), LV load center and MCC. : On-shore training for transformer protection relay. : Off-shore training at Ansaldo Caldaie Company for heat recovery steam generators (HRSG maintenance). : Off-shore training at Ansaldo Energia Company for steam turbine generator & condenser maintenance). : Training in Delta Electrical Networks in Tanta (summer 2005). : Training in Tanta Oil Co. (summer 2006). : Basic course of the Operation of Steam Power Stations (El-Kureimat I 2x650MW Steam Power Plant). : Basic course of Operation of Combined Cycle Power Plant (El-Kureimat Training Center). : Training course (LCI, SEE) through GE Company in El-Kureimat Training Center. www.egyptrol.com Page 1 of 7 Updated: Sep. 2017

: Training course (Transformer) through HITACHI Company in El-Kureimat Training Center. : Training course (MCC, Lighting, HRSG) through CMI & SKODA. : English certification from The American University in Cairo (AUC) up to Toefl I. CHRONOLOGICAL EXPERIENCE RECORD Dates : From Jun. 2016 till now Employer : SAUDI ELECTERICITY COMPANY (SEC) Project : DUBA GREEN ISCCPP PROJECT Job title : Electrical Project Engineer Job Description : SEC Representative, Responsible for supervising construction and commissioning of all Electrical works, assurance that all works have been done according to contract, Generation Engineering & Material Standard Specifications (GEMSS) and issue of punch list items. Design Review: - Review and Modified the Generator Protection System (Main & Back-up), Generator Excitation System, Excitation Transformer, Synchronizing System, 250 & 400MVA GSUT, 63MVA UAT Overall Protection, BSDG Control and Protection, VFD Transformers, ALSTOM GCB Control Panel, 250 & 400MVA - HYUNDAI GSUT Control Panel (OFAF cooling system), UAT Transformers Control Panels, AVR, Tariff Metering, Fault Recorder, Interface and interlock drawings, HSTS, ATS, Oil type power distribution transformers, Dry type transformers, 13.8KV MV SWGR (Protection & Control Ckt's), 4.16KV MV SWGR (Protection & Control Ckt's), 480V LV SWGR, ACB Feeders "Air Circuit breaker" Protection & control schematic drawings, MCC's (Motor feeders) schematic drawing review, MCC's (Non motor feeders), Dry type transformers, MV & LV Motors, IPB, SPB, NSPB, Battery chargers, UPS, Batteries, Lighting. Review the Testing & Commissioning Method Statements of: - Unit Stability Test, Protection & Control panels of Generator, Generator Excitation System, Synchronizing System, GSUT, UAT transformers (Main relays, Lockout relays, Interlock Ckt's, Metering Ckt's, Interface signals, Aux. Relays, MCB's, etc.), GSUT Transformers, UAT Transformers, AVR, Tariff Metering, Fault Recorder, Dry type transformers, Oil type distribution power transformers, GCB, 13.8KV SWGR, 4.16KV SWGR, 480v LV SWGR & MCC's, MV & LV Motors, LV Motors, IPB, SPB, NSPB, H.V & MV Cables, Battery chargers, UPS, Batteries, Metering Circuits. Review the installation method statement of: - Generator GSUT Transformers, UAT/ CAT Transformers, MV SWGRs, LV SWGRs, Control & Protection Panels, IPB, SPB and NSPB. Field Inspection of Construction work: - Installation of 400 & 250MVA GSUT, 63/40/40MVA UAT ONAF Type Transformers, 13.8KV MV SWGR, 4.16KV MV SWGR, 480V LV SWGR ACB & MCC's, Dry type transformers, Oil type www.egyptrol.com Page 2 of 7 Updated: Sep. 2017

transformer "power distribution transformers", IPB, SPB, NSPB, Battery chargers and UPS, VFD panels, Indoor lighting system. Testing & Commissioning Activities: - Schematic drawing check & update as per international standards, Contract Specifications and Site Requirements. - 280MVA Generator Test (Hipot, Stator Winding Resistance, IR Test for Stator, Rotor Winding Resistance, IR Test for Rotor). - Testing of Overall Protection Panel (GE Main Relay G60, T60). - Unit Stability Test. - Testing of 250MW (GE) Generator Protection (G60 - Differential, 100% Stator Earth Fault Low Frequency Injection Based, 95% Stator Earth Fault, Rotor Earth Fault Injection Based, Under Excitation, Over Excitation, Pole Slip, Under Voltage, Under/Over Frequency, Negative Phase Sequence, Thermal O/L, Reverse Power, Low Forward Power, Dead Machine, CBF, etc). - Testing and Commissioning of Auto & Manual Synchronizing System. - Testing and Commissioning of Generator Excitation Transformer. - Excitation Transformer O/C Relay. - Testing and Commissioning of Static Excitation System EX2100e (Function test for Bridges, OC Protection, O/P According to firing angle, Under/Over Excitation limiters, Over fluxing limiter, Stator Current limiters, Over/Under voltage limiters, etc). - Generator PTs Cubicle and CTs. - Generator Neutral Transformer. - Testing of GSUT Protection Panels (Main & Back-up) (GE Main Relays T60, C60, - Differential, Restricted Earth Fault, Over Current, Ground Fault, Over fluxing). - Testing of UAT Transformers Protection (GE Main Relays T60, C60, High Impedance MIB II - Main & Back-up). - Main protection relay test for MV&LV SWGRs. - Testing EDG Protection & Control Panels. - Testing and Commissioning of Tariff Metering Panel. - Testing and Commissioning of Fault Recorder Panel. - 400 & 250MVA OFAF Cooling Type 18/380KV GSU Transformer (HYUNDAI Manufacturer) - (Ratio, Winding Resistance, Vector group, Zero sequence impedance, Dissipation power factor, Winding insulation test, SFRA & DFRA, Dielectric oil test, mechanical protection function test, bushing CT, Magnetic balance, Excitation current test, LCP Function test, OLTC Function test. - 63/40/40 MVA Three winding ONAF Cooling UAT Transformers (ZTR Manufacturer) - (Ratio, Winding Resistance, Vector group, Zero sequence impedance, Dissipation power factor, Winding insulation test, FRA & DFRA, Dielectric oil test, mechanical protection function test, bushing CT, Magnetic balance, Excitation current test, LCP Function test, OLTC Function Test, Insulation Oil DGA, Sound level, etc). - GSUT, UAT/ AVR Function Test. - GCB - (ALSTOM Manufacturer) (Hipot Test, CTs, PTs, Insulation resistance, Contact resistance, Timing test, interlock check, GCB Monitoring relay GMS600, GCB Control panel function test). - IPB and SPB (Insulation resistance, Contact resistance, Hipot Test). www.egyptrol.com Page 3 of 7 Updated: Sep. 2017

- Oil immersed Transformers test (Ratio, Winding Resistance, Vector group, Dissipation power factor, Winding insulation test, SFRA, Dielectric oil test, mechanical protection function test, bushing CT, Magnetic balance, Excitation current test, Sound level, etc.). - Bus Bar stability test. - ATS. - HSTS SIEMENS Manufacturer (High speed transfer Switch). - 125 & 220 VDC Battery Chargers function test (JEMA Manufacturer). - UPS & DC (JEMA Manufacturer) System function Test. - SWGR Arc protection relay test. - VCB & ACB Test (Siemens Manufacturer) (Closing & Opening time, Contact resistance, Insulation test, Function test). - Metering Ckt.s Calibration. - MV / LV SWGR (CT & PT) Test. - LV SWGR & MCC auxiliary relay test. - Metering Ckt.s (Tariff Metering, Digital Power meters, Analog ammeters & voltmeters). - CT test (Ratio, Saturation Curve Knee point, Resistance, Burden, polarity). - Bus Bar test (Stability, I/R, Contact resistance & Hipot test). - Battery (Charging & Discharging) Test. - Power & Control cables test. Dates : From Oct. 2012 till Jun. 2016 Employer : Middle Delta Electricity Production Company (MDEPC) Project : BANHA 750MW Combined Cycle Power Plant Job title : Electrical Construction & Commissioning Engineer Job Description : MDEPC Representative, responsible for supervising construction and commissioning of all Electrical works, assurance that all works have been done according to contract and technical Specification and issue of punch list items. Electrical works include: - Responsible for "Electrical drawings review and approval" according to the contract specification requirements. - Coordination and supervision of all Contractors Electrical Works and identify any deviation from the contract for the following Contractors. - Generator, main transformer and Unit Auxiliary Transformers. - Generator Circuit Breakers. - GIS 220KV switchyard Hyundai & Daewoo. - MV Switchgear (Schneider Electric (MCset 1, 2, 3) SF6/ 6.3KV). - Batteries and Battery chargers and Uninterruptible Power Supply (UPS). - Medium & Low voltage cable, Interior and Exterior Illumination, Low current. - Electrical distribution Panels. - MV & LV Motors. - 6.3KV / 400V Transformers. - Lighting Systems of all Office Buildings. - Lighting Systems of the Yard. - Grounding system. www.egyptrol.com Page 4 of 7 Updated: Sep. 2017

Generators: - 324X017/018 (305 MVA HDROGEN COOLED) testing. Excitation: - EX2100e testing. LCI: - LCI 2100 (Load Commutated Inverter). GIS 220KV (Hyundai & Daewoo) SF6 C.B: - AC & DC loop test and continuity. - VT TEST: megger & turns ratio & dc resistance. - CT TEST (megger & turns ratio & dc resistance & polarity & saturation curve). - 220KV SF6 circuit breaker filling with Sf6 gas and testing (contact resistance & on/off time). - Bus bar stability & sensitivity. - Breaker failure test & auto-reclosure test & pole discrepancy test. - High voltage test for GIs. - Check interlocking. Power transformer (2 x 300 MVA) (220/15.75KV): - Function test for control cabinet. - Megger test. - Tan delta test. - Current transformer test. - Turns ratio. - Dc winding resistance. - Mechanical protection test and dielectric oil test etc.). 6.3KV MV SWITCHGEAR (SCHNEIDER SF6 C.B MC SET 1, 2, 3) 7.2KV, 40KA S.C: - Perform function of operation test and alarms and signal indication are appearing correctly. - Perform functional interlock test (electrical & mechanical). - 3-verfiy trip, close and anti-pumping function in test, local and remote position. - Sepam protective relay test (O.C (50/51) I, I, E/F (50N/51N), over voltage (59), under voltage (27), etc. with secondary injection test. - Primary injection test. - Dc contact resistance. - Megger & hipot test. Dc system: Batteries and Battery chargers and Uninterruptible Power Supply (UPS): - Battery filling and charging and discharging test. - Check battery charger mode of operation (floating, equalizing & boost). - Test all alarms for battery charger & ups and DCS signals. - Test inverter modes of operation (inverter, bypass & manual bypass). Dates : From Dec. 2009 till Oct. 2012 Employer : Upper Egypt Electricity Production Company (UEEPC) Project : El-Kureimat II & III Power Station Job title : Electrical Maintenance Engineer www.egyptrol.com Page 5 of 7 Updated: Sep. 2017

Job Description : Responsible for maintenance and troubleshooting of all electrical equipments during normal Operation as well as during minor and major overhauls. Preventive maintenance program for all types of electrical equipments according to manufacture manuals. Electrical works include: - GE & SIEMENS Generators maintenance and its excitation, LCI. - Power Transformers Maintenance (16.5/220KV & 15.75/220KV, 180/240/300 MVA). - Unit Auxiliary Transformer (16.5/6.3KV, 19.2/32 MVA). - Low voltage transformer dry type (6.3/0.4KV). - MV switchgear maintenance (ABB breakers, natus breakers, Schneider breakers). - MV & Low voltage motors (6.3KV & 0.4KV). - MCC (motor control center). - GIS 220KV (One and half circuit breaker). - Battery & battery charger. - Local control panel. - SEE & SFC. - UPS. Dates : From Jun. 2008 till Dec. 2009 Employer : Upper Egypt Electricity Production Company (UEEPC) Project : El-Kureimat II & III Power Station Job title : Electrical Construction & Commissioning Engineer Job Description : UEEPC Representative, responsible for supervising construction and commissioning of all Electrical works, assurance that all works have been done according to contract and technical Specification and issue of punch list items. As Electrical Construction Engineer: - UPPEC Representative, responsible for following construction of all electrical works in the site and putting the remarks. - Responsible for "Electrical drawings review and approval" according to the contract specification requirements. - Installing Electrical Panels. - Installing MV Switchgear (ABB & Siemens /SF6 & Vacuum C.B 6.3KV). - Installing MV & LV Motors. - Installing LV (6.3KV / 400V) Transformers. - Installing Battery Charger (125VDC/Benning). - Installing Batteries. - Installing SFC System (Static Frequency Converter) & SEE System (Static Excitation Equipment). As Electrical Commissioning Engineer: - Transformer tests (function test, megger test, turns ratio, Dc resistance, hipot test, mechanical protection test and dielectric oil test etc.). - Generator circuit breaker (ABB HEC100M Switzerland & 16.5KV- 10KA). - (Close, trip) ON/OFF Time & DC resistance by circuit breaker analyzer. - C.B (220KV (GIS) & 6.3KV & 400 V) (ON/OFF Time & DC resistance by circuit breaker analyzer tester, megger test, hipot test www.egyptrol.com Page 6 of 7 Updated: Sep. 2017

and function test). - Bus bar test (megger & hipot). - Generator (300MVA) tests (stator insulation test, rotor insulation test, DC resistance of field winding). - Function test for all panels. - Motor tests (heat run test, phase rotation, megger and DC resistance test.etc.). - Test all cables (megger & hipot test). - Loop check and continuity test. Dates : From Dec. 2007 till May 2008 Employer : Detac Company for trade and construction Project : Eastern Company at 6th of October Field of experience : Familiar with GE electrical equipments generators and its accessories excitation ex21000e, LCI and its software. MV switchgear, power transformers, GIS switchyard one and half circuit breaker. Protection relays (G60, C60, T60, SEPAM (S40, S42, B, 21, M87), SIEMENS RELAY SIPROTIC 4 (7UT612, 7SJ, 7SA522 and etc.)). Experience with main generator, transformer, switchgear, mcc, dc system, ups and relays. Ability to translate technical specifications. Problem solving and troubleshooting. Electrical testing knowledge. www.egyptrol.com Page 7 of 7 Updated: Sep. 2017