NIT for Tender No. GCO 8644P13

Similar documents
DETAILS OF THE EXPRESSION OF INTEREST(EOI) NO.: PL.G03.EOI

DETAILED NOTICE INVITING TENDER WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED. (A Govt of West Bengal Enterprise)

TENDER FOR DG SET. Tender for DG SET. POCKET-14, SECTOR-8, PHASE-1, DWARKA, NEW DELHI Website: TENDER DOCUMENTS FOR

OIL INDIA LIMITED Fax (A Govt. of India Enterprise) Udyan Vihar, Narengi, Guwahati, Assam

Supply, Installation and Commissioning of 1 No 50 Watt LED. based SPV SLS at Nadia District Library, Krishna Nagar, Nadia.

Section II -Technical Specification

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

NLC INDIA LIMITED (formerly Neyveli Lignite Corporation Limited) ('NAVARATNA'-Government of India Enterprise) MATERIALS MANAGEMENT COMPLEX

Supply of 63 kva DIESEL GENERATOR SET WITH AMF

INDIAN MARITIME UNIVERSITY KOLKATA CAMPUS

File No. EL/EE/NAD/Tech/1-13/2018/822 Dated: 29/08/2018 OFFICE OF THE EXECUTIVE ENGINEER NORTH ANDAMAN DIVISION ELECTRICITY DEPARTMENT DIGLIPUR

TECHNICAL BID T 3627

FOLDER-II दर अ स च (एसओआर) SCHEDULE OF RATES [PRICED SOR] (FINANCIAL / PRICE BID)

Section VI: List of Requirements (REVISED)

Rate (Rs.) in figure. Rate (Rs.) in words. VAT (%) Amount (Rs.) & all other taxes.

No. TE/F-814/16/WO- 145/ Dt

Technical Specifications

Dakshin Gujarat Vij Company Limited

Annexure- II (Price Bid) SCHEDULE B LIST OF ELECTRICAL ITEMS TO BE SUPPLIED

TENDER. Enq. No. IIITMK/ 0648/18 Date: 07/09/18 Due on:17/09/20183pm

REGIONAL MANAGER (VADODARA REGION)

TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH

I N D I A N S T A T I S T I C A L I N S T I T U T E

Blank Price bid (Bill of Quantity) for Part B contract

4.1 Type of the valve and materials of construction of body and trim shall be as specified in valve Data sheet.

Inviting Tenders for Supply, Installation, Testing and Commissioning of 500 KVA DG Set for Temperature Controlled Warehouse at Medchal, Hyderabad.

Hkkjrh; izca/k lalfkku dksf"kddksm

Regional Office: Vijayapura Plot No6, Trimurthy Nagar Managuli Bypass Road, Vijayapura Diesel Generator Required on Rental Basis

RAJIV GANDHI UNIVERSITY OF KNOWLEDGE TECHNOLOGIES BASAR Nirmal District, Telangana Ref: RGUKT-B/Proc/Elec,Maint/Q08/2018, dated

Tender Enquiry No: BCL / PUR / ARC / AC&DC Motors/ CW / 2019 Dated: Due on:

NOTICE INVITING TENDER

GUWAHATI MUNICIPAL CORPORATION WATER WORKS :: PANBAZAR GUWAHATI

Tender No:- MTL/PUR/213/Elect/ (K)/9. 2 NEW Moulded case Circuit Breaker with O/L & S/C No 02

01. Name of work : Hiring of A/C luxury cars and passenger Vans (As and when required) 02. Tender No. : BHE/M&S/TPT/ AC LUXURY CARS/11-12

NOTICE INVITING QUOTATIONS

Tender Schedule for Electrical Works at Varagani Branch. Sl. No. Particulars Quantity Unit Rate Amount

PART A: FINANCIAL BID

INDIAN INSTITUTE OF TECHNOLOGY, KANPUR DEPARTMENT OF ELECTRICAL ENGINEERING

BID SPECIFICATIONS 2018 TERMINAL BUILDING STANDBY GENERATOR PROJECT

Application is to be sent to the undersigned in two sealed covers on or before 21st July 2018 by 1500 hrs. as under:

SAVE ENERGY FOR BENEFIT OF SELF AND NATION

TECHNICAL SPECIFICATION FOR 11 KV CAPACITOR BANK

SUBSIDY SCHEME FOR GRID CONNCTED SOLAR ROOFTOP POJECT IN ASSAM UNDER THE 14 MW RESCO AND CAPEX MODEL

TENDER DOCUMENTS SUPPLY OF ELECTRICAL EQUIPMENT FOR BHADRAK MUNICIPALITY FOR THE YEAR LAST DATE OF RECEIVED OF TENDER DOCUMENTS :

NOTICE INVITING TENDER

INVITATION FOR QUOTATION. TEQIP-III/2018/gcej/Shopping/50

INVITATION FOR QUOTATION. TEQIP-III/2018/uceo/Shopping/48

SECTION 1 SCOPE, SPECIFIC TECHNICAL REQUIREMENT AND QUANTITIES

REQUEST FOR QUOTATION

BOXING FEDERATION OF INDIA

TENDER DOCUMENT BHARAT HEAVY ELECTRICALS LIMITED, HEEP, RANIPUR, HARIDWAR

Supply of Batteries

(A Government Company) CENTRAL WORK SHOP KOTHAGUDEM

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

: Material Description Quantity UOM

BaartaIya iva&aana isaxaa EvaM AnausaMDaana samstaana paunao

BHARAT HEAVY ELECTRICALS LIMITED, JHANSI

Formerly known as The Calcutta Tramways Co.(1978) Ltd. (Government of West Bengal Undertaking )

017: 1998 CEB STANDARD RING MAIN UNIT CEYLON ELECTRICITY BOARD SRI LANKA

Section V DC Nickel Cadmium Alkaline BATTERY

BHARAT HEAVY ELECTRICALS LIMITED Industrial Valves Plant Goindwal (AMRITSAR) Enquiry Date:

CORRIGENDUM/ ADDENDUM 09 ADDITIONAL REQUIREMENT OF ELEVATOR.

OIL INDIA LIMITED DULIAJAN

University of Peradeniya INVITATION FOR BIDS

Open Tender Enquiry OUTSOURCING OF PHOTOCOPY WORK AT SCOOTERS INDIA LIMITED SINGLE BID SYSTEM. SCOOTERS INDIA LIMITED Page 1

EOL tvo'. Eo11)E cyj

PART B: FINANCIAL BID

S P E C I F I C A T I O N

Town of South Windsor, Connecticut. Police Department

MOTHER DAIRY A UNIT OF GUJARAT CO-OPERATIVE MILK MARKETING FEDERATION LIMITED PURCHASE ENQUIRY

SPECIFICATIONS FOR MOTOR OPERATED VALVES

2017 Commercial & Industrial Program K-12 Schools Program Rebate Application

DIESEL GENERATOR NO.9 OVER HAUL SERVICE AND MAINTENACE LOCATION: TATA CHEMICLAS MAGADI POWER STATION (LAKE MAGADI)

SECTION V, 3-PHASE, 630 AMPS MCCB & ENCLOSURE

Amount (Rs) 1.5 sq. mm ISI marked, FR

TECHNICAL SPECIFICATION FOR SUPPLY OF LT DISTRIBUTION KIOSK FOR 250/315 KVA & 63/100 KVA RATING DISTRIBUTION TRANSFORMERS AGAINST TN-2077

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008

ELECTRIC MOTOR DRIVEN, SKID MOUNTED CHEMICAL DOZING PUMP. The motor shall be 3 phase, squirrel cage, AC Induction motor.

to UPS outgoing DB. c With 2 nos. 6 Sq.mm + 1 no. 2.5 Sq.mm. PVC insulated copper wire from UPS outgoing DB to CDB / Main panel to LDB /

S P E C I F I C A T I O N

NIT No.:-10/WEX/MCR/HYD. PRESS/2-303/ /Dt

Hancock County Public Schools 83 STATE ROUTE 3543 HAWESVILLE, KENTUCKY PHONE (270) FAX (270)

NETWORK ELECTRICAL TECHNOLOGY LLC

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

TECHNICAL SPECIFICATIONS FOR STEEL PLATES

GUIDE TO MAINTENANCE PRACTICES FOR DISTRIBUTION NETWORKS IN THE DISTRIBUTION SECTOR OF THE NAMIBIAN ELECTRICITY SUPPLY INDUSTRY

UNIVERSITY OF CALCUTTA Centre for Research in Nanoscience and Nanotechnology JD-2, Sector-III, Salt Lake City Kolkata

II) FOR THE ATHENS TRAMWAY RFP-311/17 Α.Σ FINANCIAL OFFER. FINAL Page 1

MOTHER DAIRY A UNIT OF GUJARAT CO-OPERATIVE MILK MARKETING FEDERATION LIMITED PURCHASE ENQUIRY

Tamilnadu Trade Promotion Organisation, Chennai-89

(LAST DATE OF SUBMISSION: ) QUOTATION FOR ANNUAL MAINTENANCE CONTRACT OF SERVERS, COMPUTERS, PRINTERS, NETWORKING AND LAN

Three (3) New Ford Fusion Sedans Bid No Notice to Bidders

FORMAT B (Annexure-III)

We msckolkata are one of the leading traders and Suppliers of high quality assortment of Electrical products, Spares and Allied products.

TENDER. 2017, THREE QUARTER (3/4) TON PICKUP TRUCK, 4x4

TENDER HALF TON PICKUP TRUCK, 4x4

INVITATION FOR QUOTATION. TEQIP-II/2015/GJ1G02/Shopping/M-EE-09

ATTACHMENT A - STATEMENT OF WORK INVITATION TO BID FOR CHILLER INSPECTION SERVICES ITB NO.: DMS-13/14-035

TECHNICAL BID T 3610

FLOAT CHARGER (40A) & BOOST CHARGER (35A) FOR NO BREAK POWER SUPPLY SYSTEM WITH REQUIREMENT FOR SCADA

Transcription:

NIT for Tender No. GCO 8644P13 Oil India Limited, a Government of India Enterprise intends for hiring the Electrical Maintenance services by a team comprising of 1 (one) Electrician (with valid electrician s license issued by State Electrical Licensing Board) & 1 (one) helper for a period of 1 (one) year under Pump Station No. 8, Oil India Limited, Sonapur, P.O. Haptiagach, Dist. Uttardinajpur (West Bengal). Interested bidder may purchase the Bid Documents against payment ` 500/- (Rupees Five hundred only), in the form of demand draft from schedule Bank payable to Oil India Limited, Guwahati, from (i) office of the Chief Manager (Contracts) Guwahati 781 171 or (ii) Dy. Chief Engineer (E&C), PS.8 Sonapur from 28.01.2013 to 27.02.2013 during office hours from 8.00 AM to 10.00 AM. The Bid Closing Date (BCD) is as under: If the bid is submitted at: i) Guwahati then BCD 04.03.2013 at 13.30 Hrs. ii) PS-8, Sonapur then BCD 28.02.2013 at 13.30 Hrs. Tender Reference is GCO8644P13. BID REJECTION CRITERIA (BRC) [1] Financial capability: Bidders must have Average Annual financial turnover as per Audited Annual Reports for the last three accounting years should be at least ` 92,400/- For Proof of Annual Turnover any of the following documents /photocopy must be furnished: A Certificate issued by a practicing Chartered / Cost Accountant Firm, with membership number certifying the Annual Turnover and nature of business. Audited Balance Sheet and Profit & Loss account. [2] Experience: Bidders must have; Experience of having successfully completed similar works during last 7 years ending last day of month previous to the one in which applications are invited should be either of the followings: 2.1 Three similar completed works each costing not less than ` 1,23,200/- Or 2.2 Two similar completed works each costing not less than ` 1,53,900/- Or 2.3 One similar completed works each costing not less than ` 2,46,300/- Similar works shall mean work of Electrical Maintenance/Service OR Earthing grid/earth pit Work OR Electrical wiring work OR Electrical Cable/Overhead line work in any Petroleum Industry / Hazardous area. The Bidder must possess valid Electrical Contractor s License from West Bengal Electrical Licensing Board OR have experience in Electrical Maintenance OR Service in any Petroleum Industry / Hazardous area.

[3] For proof of experience, the following document must be submitted along with the bid: 3.1 In case of OIL contractor, copy of certificate of completion (COC)/Work Order showing gross value of job. It may be clearly noted that simply mentioning of OIL COC/WO no. will not be accepted. 3.2 Certificate issued by any other firms of repute within last three years experience from the date of opening the bid, showing: a) Gross Value of Job done; b) Nature of job done; and c) Time period covering the financial year(s) as per NIT. [4] SPECIAL TERMS & CONDITIONS: 4.1 SCOPE OF SERVICE The electrical maintenance service team deployed by the bidder shall be competent to carry out the following electrical maintenance work and shall execute the works as described below as per specific instructions of OIL. 4.1.1 Routine/ Preventive Maintenance 1-phase/ 3-Phase Induction motors including Shifting, Cleaning of different parts of the motor, Change of grease, Varnishing, Checking the tightness of the power and control cables in the Motor terminal box and its control panel, Bearings / lugs replacement (if required), Measurement of the IR value of the motors, Painting of the body of the motor Using necessary tools & tackles, cleaning of working area and other related activities and all other miscellaneous jobs including cleaning of working area as per 4.1.2 Routine/Preventive Maintenance of LT Air Ckt Breakers & its control & relay panel including Cleaning of busbar, Changing of breaker parts (Trip coil, closing coil, spring etc.), Tightening of all power and control cables, Insulation resistance test, Shifting necessary test kits & accessories to the site & other related activities that may be required for the maintenance of breaker as per 4.1.3 Field testing including shifting of the test kits, accessories & making necessary arrangement for Testing & barricading the testing area for Insulation Resistance test of LT cables & LT motors, Transformers, CTs, PTs etc, Cable fault locating, Cable Identifier test & other tests Required at site as per 4.1.4 Routine/Preventive Maintenance of 3-Phase, LT motorised Valve Actuators including, Disassembly and Reassembly of actuators including replacement of power & control cables (if required),tightening of power & control cables in the actuator & its feeder panel, Cable glanding (FLP Type), ferruling, lug fixing, termination etc., Replacement of power & control cards & Limit & Torque Switch assembly and all other miscellaneous jobs including cleaning of working area as per 4.1.5 Routine/Preventive Maintenance of 25 KVA DG Sets including General cleanliness, Tightening of power & control cables, self starter servicing, testing of protective relays and all other miscellaneous jobs including cleaning of working area as per instruction of OIL INDIA LTD. 4.1.6 Routine/Preventive Maintenance of LT feeder panels including Cleaning of the panel, Tightening of power & control cables, Disassembly and Reassembly of Modules, Fault Rectification /Replacement of SFU, Power Contactors, O/L Relay MCB/ELCB, Timer

Switch etc. and complete the job in all respect including cleaning of working area as per 4.1.7 Maintenance of Electrical Lighting System including New Installation, Shifting,Changing & Fault Rectification of FLP & non-flp 70W/125W/160W/250W/400W, HPMV/ HPSV/MLL/Metal Halide lights upto 9 metre height, Cleaning of glass covers of HPMV/ HPSV/MLL/Metal Halide lights along with its luminaries 9 metre height, Replacement & Fault Rectification of FLP control gear box accessories viz capacitor, Igniters, ballast etc., including cable glanding, ferruling & termination in the FLP junction boxes & its feeder panels and complete the job in all respect including cleaning of working area as per 4.1.8 Maintenance of Electrical Lighting System including New Installation, Changing & Fault Rectification of 20W/40W Fluorescent Tube Light fixture, choke, starter, holder etc., New Installation, Changing, Shifting & Fault Rectification of 9W/11W CFL Light fixture, choke, starter, holder etc, and complete the job in all respect including cleaning of working area as per 4.1.9 Maintenance of Electrical Wiring System including attending & Fault Rectification of lighting feeder panel/ distribution board/switch board including changing of SFU,MCB/ELCB, terminal block, switch board, switch(5/15a),socket(5/15a) burnt wire, loose connections, sealing of spare holes & attending small defects etc., New Installation /Shifting of Switch Socket Board (normal & industrial type), Switch Board, Distribution Board/Box from existing location to a new location including making of hole in the wall & Connecting the same with PVC insulated wire including proper dressing from the power source and complete the job in all respect including cleaning of working area as per 4.1.10 Replacement/ rectification of HPMV/ HPSV/ metal halide lamp/ Street Light Pole (height upto 10m) or glass lamp cover of fixture, holder, condenser, choke/ ballast, igniters junction box etc, and complete the job in all respect including cleaning of working area as per 4.1.11 Maintenance of Earth Pit such as Cleaning of earthpit and surrounding area, Removing rust, replacement/ tightening of nut-bolts, Earth resistance test of earth pits (half yearly) Necessary treatment of the earthpit to improve the value of earthpit, Writing of measured earth resistances, and complete the job in all respect including cleaning of working area as per 4.1.12 Replacement of 240V AC ceiling fan/ Exhaust fan/ Wall fan (Air circulator) with regulator including Fault Rectification of capacitor, switch, regulator, wiring, tightening of supporting nut bolts/ rod etc, Shifting of ceiling fan/ exhaust fan(normal & heavy duty), Room heater, Storage Water Geysers from one location to another & reinstall after repairing and complete the job in all respect including cleaning of working area as per instruction of OIL INDIA LTD. 4.1.13 Termination of PVC insulated armoured power /control cables (upto 1100v grade) including shifting of cables from store to work, Glanding (FLP/Normal), Ferruling, Lug fixing & Termination of cables and complete the job in all respect including cleaning of working area as per 4.1.14 Attending emergency lighting & miscellaneous electrical job if required in field area during operation exigencies as per direction of OIL.

4.1.15 General cleaning/upkeepment of electrical equipments,using necessary materials & tackles, cleaning of working area and other related activities and any other job that may be required as per 4.1.16 Maintenance Support for Window / Split / air conditioners, refrigerator, water-cooler, room heaters/heat convectors. 4.2 IMPORTANT NOTE 4.2.1 All persons deployed by the bidder shall be given only weekly off-days. Bidder to note that during such weekly off-days no reliever is required to be deployed. 4.2.2 In case of any absence due to leave, sickness etc [excluding weekly-off day] the bidder shall arrange for a suitable replacement having the same competency level. In case of bidder's inability to provide the replacement personnel, OIL shall deduct amount on Pro- Rata basis from the bidder. For the basis of calculation the amount deductable per day shall be as under: - Electrician = 56% of PSE - Electrical Helper = 44% of PSE c) The unit price quoted by Bidder should be in the unit/format as specified in the tender document. The quoted unit rate should be inclusive of Service Tax, PF, ESI, Bonus, cost of PPE, transportation, accommodation etc.

[4] Evaluation of Bids: The Bids will be evaluated as per the Bid Evaluation Criteria (BEC) as stated herein under: BID EVALUATION CRITERIA (BEC) 4.1 Bids conforming to the terms and conditions stipulated in the bid document and considered responsive and subject to qualifying the Bid Rejection Criteria will be considered for further evaluation. 4.2 To ascertain the inter-se-ranking, the comparison of the responsive bids will be made on the basis of total amount quoted for the items of SOQ of the tender. 4.3 Any discount/rebates offered shall not be considered for evaluation of bids. However, if the lowest bidder happens to be the final acceptable bidder for award of contract and if they have offered any discount/rebate the contract shall be awarded after taking into consideration such discount/rebate after negotiation or otherwise.