INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR ABTECH PCS Cntrl Statin Purpse f Instructins Wrking in hazardus areas, the safety f persnnel and plant depends n cmplying with all relevant safety regulatins. Installatin and maintenance persnnel wrking n installed prduct have a particular respnsibility t ensure any applicable standards and regulatins are cmplied with. These instructins give a brief summary f the mst imprtant safety measures. It shuld be read in cnjunctin with the prduct certificate and any applicable natinal and lcal regulatins. Safety Instructins The PCS cntrl statin shuld be used nly fr its intended purpse. PCS cntrl statins are nt suitable fr Zne 0 hazardus areas! N alteratins t the apparatus is permitted. The PCS cntrl statin shuld nt be used if damaged Any damage may invalidate the Ex prtectin. Observe the fllwing during installatin and peratin: Any relevant Natinal safety regulatins; Lcal safety regulatins: Internatinal installatin regulatins(e.g. IEC 60079-14); The fllwing installatin instructins cntained in this manual Any values r instructin printed n the apparatus label. The PCS cntrl statins are designed, manufactured and tested in accrdance with ISO 9001. The PCS cntrl statins cmplies the fllwing standards: IEC60079-0:2004 EN60079-0:2006 IEC60079-1:2003 EN60079-1:2004 IEC60079-7:2001 EN60079-7:2003 IEC61241-0:2004 EN61241-0:2006 IEC 61241-0:2004 EN61241-0:2006 Applicable Scpe The functin f the apparatus is based n the perfrmance and use f built-in cmpnents. The permissible Ex cmpnents can be used as fllwing: CZ0201 Series Explsin-prf switch mdule. This mdule can be used in the PCS cntrl statin when installed in a circuit where rated wrking vltage is AC250V (+28%) r belw t cntrl electrmagnetic starter, cntactr, relay and ther electric circuits. CZ0202 Series Explsin-prf signal lamp. Lamp mdules can be used in the PCS cntrl statin where wrking vltage is AC24-240V r DC24-36V. The crrect mdule shuld be chsen fr the applicable wrking vltage. CZ0205 Series Explsin-prf ammeter mdule. The ammeter mdule can be used t measure r display the current in an ac circuit. Technical Data Cding: Cntrl statin with ammeter nly: II 2GD Ex e IIC T6/Ex td A21 IP66 T80ºC -40 C Tamb 40 C Cntrl statin(except with ammeter nly): II 2GD Ex de IIC T6/Ex td A21 IP66 T80ºC -40 C Tamb 40 C Certificate n.: DNV 12 ATEX 13746 Degree f prtectin: IP66 Ambient temperature: -40 C Tamb 40 C Material f enclsure: Plyamide Tightening trque fr cver screws: 2.0Nm Internal earthing: Terminal 2x 2.5mm² (tightening trque: 1.1Nm) 1/5
Main technical data f built-in Ex cmpnents: CZ0201 Series Explsin-prf switch mdule G ll 2G Ex de llc Test certificate: IECEx CQM 08.0005U DNV-2008-0SL-ATEX-21657U Degree f prtectin : IP20 Rated vltage: 250V; Rated current: 16A max. Rated insulatin vltage: 690V Rated withstand vltage: 6KV (U imp ) Cnventinal clsed heating current: -55ºC Ta 40 C - I the 16A; -55ºC Ta 60ºC - I the - 10A Breaking capacity: Rated vltage 250V 250V 110V 24V Utilisatin categry: AC12 AC15 DC13 DC13 Rated current: 16A 10A 0.5A 1A Cntact type: 1N0+1NC, 2NC, 2N0 Mechanical life: 10 6 times (3600/h) Cnnectin type: Terminal 2 x 2.5mm²(With spring washer). Terminal material 304 stainless Cnnecting lead: 2 x 2.5mm² (tightening trque: 1.1Nm) CZ0202 Series Explsin-prf signal lamp mdule G ll 2G Ex de llc Test certificate: IECEx CQM 08.0006U DNV-2008-0SL-ATEX-21658U Degree f prtectin : IP20 Rated insulatin vltage: 300V; Rated service vltage: AC24 ~ 240V DC24 ~ 36V Electrical life: 10 5 wrking hurs Ambient temperature: -55ºC Ta 60ºC Cnnectin type: Terminal 2 x 2.5mm²(With spring washer). Terminal material 304 stainless Cnnecting lead: 2 x 2.5mm² (tightening trque: 1.1Nm) CZ0205 Series Explsin-prf ammeter mdule G ll 2G Ex e ll Test certificate: IECEx CQM 08.0007U DNV-2008-0SL-ATEX-21659U Rated insulatin vltage: 690V Accuracy class: 1.5 Operatin type: Electrmagnetic Ambient temperature: -40ºC Ta 60ºC Cnnectin type: Terminal 2 x 2.5mm²(With spring washer). Terminal material 304 stainless Cnnecting lead: 2 x 2.5mm² (tightening trque: 1.2Nm) P /K /L Switch Operatrs G ll 2GD Ex e ll Ex td A21 Test certificate: IECEx CQM 08.0012U DNV-2008-0SL-ATEX-46028U Degree f prtectin: IP66 Ambient temperature: -40ºC Ta 55ºC Tightening trque: 5Nm (peratr retaining nut) Cable Glands: Certificatin level: G ll 2GD Ex e ll Ex td A21 (Atex certified) Degree f prtectin: IP66 Ambient temperature: -40ºC Ta 55ºC Tightening trque: M20 x 1.5p 3.0Nm; M25 x 1.5p 4.0Nm 2/5
PCS Cntrl Statin Dimensins PCS01-95 X 86 x 76 PCS02-135 x 86x 76 PCS03-175x86x 76 PCS05-175x 100 x 76 PCS06-215x 100 x 76 PCS01 PCS02 PCS03 PCS05 PCS06 PCS51 Type Operatr L (mm) Type Operatr L (mm) P1 Pushbuttn (rubber) 15.5 K4 K8 Selectr Switch (small) 30.5 P2 Duble Pushbuttn (Rubber) 15.5 S4 S8 Selectr Switch (large) 30.5 P3 Emergency Stp 41.2 L Signal Lamp Bezel 22.6 P4 Black Mushrm Head 41.2 P /B1 Illuminated Pushbuttn/Stpping Plug 17.5 Y0 Red Mushrm Head (key) 24.0 DW Ptentimeter Head 30.5 Y1 Pushbuttn (key) 28.0 EXM Ammeter Windw 12.0 L = Height f peratr head frm frnt face f cntrl statin (mm) 3/5
Operatin & Installatin ABTQ-103 rev 01 Transprt and strage in riginal packaging nly. Any natinal r lcal safety and/r installatin regulatins and gd engineering practice must be bserved when munting and perating this equipment. The user shall bserve the fllwing cnditins in rder t ensure the safe peratin f the PCS cntrl statin. The Abtech PCS cntrl statin is suitable fr use in hazardus areas, zne 1, 2 and 21, 22. The Abtech PCS cntrl statin shuld be used under the fllwing atmspheric/ambient cnditins: The pressure is 80kPa(0.8bar)-110kPa(1.1bar) The vlume rati f standard xygen cntent is 21% air; The Ambient relative humidity is less than: 95%; The PCS cntrl statin is designed fr use subjected t nrmal industrial levels f vibratin. It shuld nt be munted such that it is expsed t excessive levels f vibratin r shck. Cnductrs must be cnnected with due care, e.g. multi stranded cnductrs shuld be fitted with a ferrule Insulatin must be stripped back n mre than 1mm frm thrat f terminal; Damaged cnductrs r cnductrs with damaged insulatin shuld nt be used; All screws, used and unused, n the cnnectin terminals, must be fully tightened. This shuld be checked prir t cmmissining; The earth cnductr shuld be at least the same crss sectinal area as the live cnductrs; It is the users respnsibility t ensure the IP rating f the apparatus is maintained; Cautin: de-energize befre pening! Cable gland & stpping plug Only certified cable glands and stpping plugs shuld be used with this apparatus. If a cable gland r stpping plug with degree f prtectin lwer than IP66 is used, the IP rating f the apparatus will be reduced t that f the entry device. (Cable gland r stpping plug must have minimum IP rating: IP54) The installatin, peratin and maintenance instructins applicable t the cable gland r stpping plug must be adhered t. Ensure that the cable gland, apprpriate fr the cable diameter and type is used. Unused peratr hles and cable entry hles must be clsed with a certified blanking plug apprpriate fr the hle diameter in rder t ensure the required minimum prtectin categry. IMPORTANT: Cable glands and stpping plugs shuld be tightened accrding t the manufacturers instructins. Care shuld be taken nt t ver tighten f cable glands r blanking plugs as this may impair the ingress prtectin prperties f the device. Cmpnent Installatin Cntact Blck/Lamp Mdule The required cntact blck/lamp mdule (item 1) shuld be snapped nt the plastic rail mulded int the bdy (item 2) ensuring that it clicks int ne f the spacing slts. Plastic Mulded Earth Terminal Plastic earth terminal (item 3) can be fitted t either the tp r bttm f the enclsure (item 2) Metal Earth Plate Where metallic cable glands r stpping plugs are used they shuld be fitted t the metal earth plate (item 4) The metal earth plate is threaded t suit the apprpriate cable gland r stpping plug. Cmbining Enclsures It is permissible t jin tw enclsures tgether using the cnnecting blt (item 5) and lcknut (item 6). Crrespnding 25mm diameter hles shuld be drilled in the adjining faces f the enclsures t be cnnected and the seal (item 7) clamped between the tw enclsures. 4/5
Installatin f Operatr/Lamp Bezel The peratr/lamp bezel (item 8) shuld be fitted t the cver, ensuring that the tab n the peratr is aligned with the keyway in the cver hle. The lcknut (item 10) shuld be fitted t the rear f the peratr and tightened using the apprpriate scket spanner (item 9) t the recmmended trque f 5Nm. Ensure that the actuating pins f the peratr align with the plungers in the cntact blck r the lamp bezel aligns with the lamp mdule. Operatr Label The labels (item 11) fitted t the peratr heads may be changed by placing screwdriver r ther implement behind label and levering ff. New label is push int slts. Tag Labels Tag labels may be fitted t the tp f the enclsure as shwn. IP Cver Key perated pushbuttns may be supplied with an IP cver which shuld be replaced when the key is nt being used in rder t maintain the IP rating f the enclsure. Cmpnents and Spare Parts Only, peratrs, bezels, cntact blcks and lamp mdules supplied by Abtech shuld be fitted t the PCS cntrl statins. Similarly, nly spare parts supplied by Abtech shuld be used. Maintenance The cnditins f certificatin and any special cnditins fr safe use, nted in the certificate shuld be strictly adhered t, alng with the instructins laid dwn in this manual. The apparatus must be de-energised prir t remving the cver r replacing any parts. This wrk must be carried ut by a cmpetent persn. The fllwing shuld be checked during maintenance: Check fr cmpliance f the apparatus with respect t ambient temperatures. Check fr any damage t seals and gaskets. Check fr any damage t cntact blck/lamp mdule and peratr head/lamp bezel. Check cntact blck/lamp mdule is securely psitined in enclsure Check cntact blck/lamp mdule terminals fr tightness Check cnditin f cnductrs and wiring insulatin Check earth cnnectin Check cable glands/stpping plugs as per manufacturers recmmendatins. Clean exterir f enclsure with a damp clth t remve any build up f dust. Dispsal/Recycling Any lcal r natinal regulatins regarding the dispsal f this equipment shuld be adhered t. Fr further infrmatin please cntact Abtech technical department. 5/5