V400D VERIS Verabar (Double Rod) Installation and Maintenance Manual

Similar documents
V200D VERIS Verabar (Double Rod) Installation and Maintenance Manual

V500 and V510 VERIS Verabar Installation and Maintenance Manual

V150 VERIS Verabar Installation and Maintenance Manual

CV Control Valves Installation and Operation Manual

PT-516 Pumping Trap Installation and Maintenance

Armstrong Steam Filters (ASF)

Digital-Flo TM Boiler Water/Water Plate & Frame Heat Exchanger

Orifice Flange Union Assembly and Orifice Run Installation and Operation Manual

Rosemount 485 Annubar Threaded Flo-Tap Assembly

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

User Guide IM/TORBAR-EN Rev. D. Averaging pitot tubes

Model Specifications V400S V400D Sensor Code Sensor Diameter 7/16 (11mm) 7/8 (22mm) 1-3/8 (35mm) 7/8 (22mm) 1-3/8 (35mm) Accuracy

Rosemount 585 Annubar Flanged Flo-Tap Assembly

V550 Spring Lock Flanged Connection with Packing Gland

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

Regular Models. V150 Spring Lock Threaded Components

DeZURIK 2 20" BOS BUTTERFLY VALVES

Rosemount 285 Annubar Pak-Lok Assembly

V200S. ±1% of flow rate; up to +/-0.5% if calibrated ANSI Class* 600# 150# 150# 600# 600# Drive Rods Single Double (150mm-1050mm)

DeZURIK KUL KNIFE GATE VALVES

DeZURIK 2-24 (50-600mm) KGC ES or HD KNIFE GATE VALVES

DeZURIK KGC-MD KNIFE GATE VALVES

DeZURIK 2-24 (50-600mm) KGN-RSB BI-DIRECTIONAL CAST STAINLESS STEEL KNIFE GATE VALVES

300 Series INSTRUCTION MANUAL. Compressed Air Filters Models 302 (grade) through 317 (grade)

TITAN 13 x 2½ BRAKES DUO-SERVO AND FREE BACKING

PREMIER, MARINE, & STANDARD

Scale Feeder Manifold Water Filtration System Instruction Manual

DeZURIK 24 and Larger BHP High Performance Butterfly Valves WITH (FB) FYRE-BLOCK SEAT

Dual/Triple Manifold Water Filtration Systems Instruction Manual

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

ActuLink ABS Module - ABS-MOD-400

INSTALLATION INSTRUCTIONS

APCO CSV-1600 SURGE CHECK VALVE

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

Installation, Operation, and Maintenance Manual

Rosemount 485 Annubar Pak-Lok Assembly

Watts Series CSM-91. Grooved/Flanged Flow Measurement/Balancing Valves. Installation and Operating Instructions. Table of Contents. 1.

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

TBM Series 3-Way Ball Valve

Colt Series C400, C500

INTRODUCTION INSTALLATION

Annubar Flowmeter Series

DeZURIK KSV CL150 & CL300 BONNETLESS KNIFE GATE VALVES

HR-20P Pneumatically Controlled Pressure Regulator

DeZURIK 24" THRU 36" RESILIENT BUTTERFLY VALVES

CAST STEEL FLANGED GATE, GLOBE, & CHECK VALVES

DODGE CUMMINS MK-2 Micro-Kleen System

Dual Port Manifold Water Filtration Systems Instruction Manual

TITAN FLOW CONTROL, INC.

MEX (55) QRO (442) Web Controls

Rosemount 485 Annubar Flanged Assembly

Nor East. Instructions Safety Messages. Inspection. Parts. DeZURIK Service. Type 05 Pneumatic Actuator Used With Globe Valves

APCO CVS-250/250A SWING CHECK VALVES

APCO CVS-6000 CONVERTIBLE SWING CHECK VALVES

Operator's Manual. Models (¾") (1") (1½ ) (2 ) (3") (4") (6") (8")

6701 KNIFE GATE VALVES

Flange Spreader Parts and Operating Manual

MetroPrime 22MPC Self-Priming Centrifugal Pump

Installation Service Repair Kits Maintenance RP/IS-774/774DCDA/774X/774XDCDA

AVK SERIES 41 SWING CHECK VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR SWING CHECK VALVES 3" - 12"

Installation Instructions and Service Manual

Caution. Do not operate your Micro Rain traveler without a serious overview of this manual. Keep children and unauthorized people away from traveler

SUNTURA SOLAR TRACKER

Dual Flow Manifold Systems Instruction Manual

StormPro BA Series Sump Pump

LEXION SINGLE FUNCTION HYDRAULIC VALVE KIT

HAYWARD FLOW CONTROL TBH SERIES TRUE UNION BALL VALVE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

DeZURIK VPB V-PORT BALL VALVES

Harley Davidson FL Touring Current Xtreme

Model 66/660* Actuator for Trailer Brakes 6,600 lbs Capacity Drum Brake Ready or Disc Brake Ready US Patent No. 6,375,211

INSTALLATION, INSTRUCTION AND SERVICE MANUAL

Installation Instructions and Service Manual

Slimline Duals Installation Instructions Harley-Davidson Touring Models 2009-Current

INSTALLATION INSTRUCTION & OWNER S MANUAL

FK75 / FK95 Quick Installation Guide

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser

EZ-IN Series Turbine Flowmeter

METERING VALVE 2" STEM GUIDED

GA Industries, LLC 9025 Marshall Road Cranberry Township, PA USA Telephone (724) Fax (724)

ALULIFT Portable Aluminium Gantry Crane Operation & Maintenance Instructions

DODGE CUMMINS Arctic-Heat Grid Relocation Kit

EWS FLUID END PARTS LIST

Richmond Conveyor. Hydraulic Ultimate Manual. January 2013

Flow Control. Before installation or maintenance, these instructions must be fully read and understood.

Installation Instructions GOOSENECK MOUNTING KIT Chevrolet/GMC 1500/2500/3500 All except 4-door Crew-Cab

OWNER S GUIDE 8A DURALIFT II 13,200 LB. CAPACITY. Link Mfg. Ltd th St. N.E. Sioux Center, IA USA

Venturi Flow Meter Installation and Operation Manual

Series 957, 957N, 957Z, 957RPDA, 957NRPDA, 957ZRPDA

AVK SERIES 41 SWING CHECK VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR SWING CHECK VALVES 3" - 12"

DeZURIK AFR3 Filter Regulator Used on Pneumatic Cylinder Actuators

Watts Series CSM-61. Flow Measurement/Balancing Valves Sizes: 1 1 4", 1 1 2", 2", 2 1 2", and 3" (32, 40, 50, 65 and 80mm) Installation Instructions

4000SS. For other repair kits and service parts, send for Ames Repair Parts Price List, PL-A-RP-BPD.

Val-Matic 1-4 Combination Air Valve (Single Housing Type)

FIGURE 310A & 311A 3-PIECE BALL VALVE

Installation & Operating Instructions for Zone Valve Boxes & Ball Valves

Grinnell Grooved Fire Protection Products Grooved Fittings

Liquid Turbine Flowmeter

Installation Instructions

CLIF MOCK TM. Model 5030 Orifice Fitting. User Manual. Manual No , Rev. B

Spring-Engaged/Hydraulically-Released BD Caliper Brake. (i) MTY (81) QRO (442) MEX (55)

Transcription:

V400D VERIS Verabar (Double Rod) Installation and Maintenance Manual 168-EN Please read and save these instructions

Contents General Safety Information...3 Product Information...3 Section 1: Scope...3 Purpose of this Manual... 3 Section 2: Receiving and Inspecting Receiving and Inspecting the Verabar... 3 Section 3: Safety Precautions...3 Safety Messages and Application Requirements... 3 Section 4: Installation Preparations... 3-5 Location... 3 Orientation... 4 Horizontal Piping... 4 Vertical Piping... 5 DP Transmitter/Local Indicator Location... 5 Installation Drawings and Bill of Materials... 5 Section 5: Installation Procedure... 6-9 Preparing the Pipe... 6 Fitting Welding...6-7 Packing Body... 7 Sensor Insertion...7-8 Insert Instrument Vales or Manifold... 9 Valves... 9 Manifold... 9 Pipe Pressurization... 9 Section 6: Proper Installation... 10 Section 7: Periodic Maintenance... 10 Limited Warranty and Remedy... 11 2 Designs, materials, weights and performance ratings are approximate and subject to change without notice.

General Safety Information Instructions and procedures listed in this manual may require special precautions to ensure the safety of the individuals performing the operations. Review the entire manual, taking note of safety messages prior to performing any operations listed in the manual. Product Information The VERIS Verabar averaging pitot flow sensor provides unsurpassed accuracy and reliability. With its solid, one-piece construction and bullet shape the VERIS Verabar makes flow measurement reliable and precise. The unique sensor shape reduces drag and flow induced vibration. The location of the low-pressure ports eliminates the potential for clogging and improves signal stability. The V400D model can be inserted and removed from service under pressure. It features double drive rods and flanged mounting components. Section 1 Scope These instructions provide a description of procedures for installing the V400D (Double Rod) Verabar flow sensor. Procedures are given for all industrial flow measurement applications including liquid, steam and gas for both horizontal and vertical piping configurations. Section 2 Receiving Inspection The following tasks should be performed as part of the receiving inspection procedure: Check items received against the packing list. Check sensor nameplate for proper model number, serial number and tag number. Verify the actual pipe diameter matches the ID stated on the sensor nameplate. Check the bullet shaped sensor tube for any signs of damage. Damage to the sensor tube may result in erroneous flow readings. Check the round cover tube for any damage, especially axial gouges or scratches. Damage to the cover tube may prevent the packing from sealing properly. Section 3 Safety Precautions The following process should be conducted prior to installing the Verabar flow sensor: Check the maximum operating conditions on the flow sensor nameplate. Verify that the maximum operating conditions of the application do not exceed the parameters stated on the nameplate. If any pressure, temperature or flow limits will be exceeded, contact the factory before proceeding. Section 4 Installation Preparations 4.1 Location For the most accurate flow measurement, a minimum straight run of pipe is required. Table 1 shows the minimum straight run requirements. If longer straight runs are available, position the Verabar such that the ratio of upstream straight run to downstream straight run is approximately 4 to 1. If straight run lengths are less than the values stated in Table 1, contact Armstrong s VERIS Flow Measurement Group directly. Straightening vanes should be positioned such that the end closest to the Verabar is half way between the Verabar and the closest upstream configuration. For elbow installations, mount the Verabar in the same plane as the closest upstream elbow. Designs, materials, weights and performance ratings are approximate and subject to change without notice. 3

Table 1. Straight Run Requirements 4.2 Orientation Verify the proper sensor orientation by checking for an -H (horizontal piping) or a -V (vertical piping) in the model number on the Verabar name plate. Verify that the flow arrow stamped on the instrument head is pointing downstream in the direction of flow. 4.2.1 Horizontal Piping For air or gas installations, mount the Verabar in the upper 160 of the pipe to allow any condensate to drain into the pipe (Figure 1). For liquid or steam installations, mount the Verabar in the lower 160 of the pipe. This allows any entrained air to bleed back into the pipe for liquid applications and allows condensate to collect in the instrument piping for steam applications. 4 Designs, materials, weights and performance ratings are approximate and subject to change without notice.

160 AIR AND GAS LIQUID AND STEAM 160 Figure 1. Verabar Orientation in Horizontal Pipe 4.2.2 Vertical Piping The Verabar may be mounted in any location around the circumference of the pipe for vertical piping applications. 4.3 DP Transmitter/Local Indicator Location When choosing a Verabar location, consider the DP transmitter/local indicator location: The transmitter must be mounted below the Verabar for liquid and steam applications. The transmitter must be mounted above the Verabar for air and gas applications. 4.4 Installation Drawings and Bill of Materials Additional information is available in the Installation Drawings and Bill of Materials VB-7061. (Contact factory for access information). It contains standard and alternate transmitter locations and a complete bill of materials based on the fluid type and sensor orientation on the pipe. 4.5 Piping Support For sensors that extend more than 36 (915mm) beyond the pipe wall or for sensors mounted in thin-walled pipes, external support of the Verabar is recommended. This will reduce stresses on the pipe wall. Designs, materials, weights and performance ratings are approximate and subject to change without notice. 5

Section 5 Installation Procedure 5.1 Assemble The Verabar Your Verabar is shipped loosely assembled and is not properly tightened for proper pressure retention. Follow all assembly steps to ensure a safe installation (see Figure 2). 5.2 Insert Instrument Vales or Manifold 5.2.1 Valves If the Verabar does not have a valve head, install instrument valves using proper thread sealant. Be sure instrument shut-off valves are installed and shut prior to re-pressurizing the pipe. 5.2.2 Manifold If the Verabar has a direct or integral manifold, be sure the high and low pressure block valves are shut off prior to re-pressurizing the pipe. Sensor Plate Sensor Bushing Instrument Head Drive Nut Packing Bolts Jam Nut Threaded Drive Rod Stop Nut Packing Gland Threaded Bushing Access Nipple Cover Tube Sensor Studs & Nuts Gasket Gasket Studs & Nuts Access Valve Mounting Flange Hot Tap Drilling Mechanism (Not Supplied) Figure 2. Verabar Model V400D (Double Rod) Access Nipple Tip of Sensor Flush with End of Access Nipple Flange Face Figure 3. Access Nipple Packing Gland Cover Tube 6 Designs, materials, weights and performance ratings are approximate and subject to change without notice.

5.3 Retract Sensor and Tighten Packing Retract the Verabar such that the tip of the sensor is flush with the end of the access nipple (Figure 3). Tighten the three packing bolts on the packing gland. 5.4 Weld Mounting Flange to Pipe Mark the location where the Verabar is to be mounted. Position the mounting flange over the center of the mark. Using the appropriate weld gap (1/16 [1.5mm] typical), tack weld the mounting flange into position. Note the flange orientation per Figure 4. The bolt holes on the flange should straddle the centerline of the pipe (2-holing pattern). Finish welding the mounting flange to the pipe per applicable codes. 4-Hole Bolt Pattern Pipe Wall Bolt holes on flange to straddle the centerline of the pipe (2 holing pattern) 8-Hole Bolt Pattern Pipe Wall Bolt holes on flange to straddle the centerline of the pipe (2 holing pattern) Figure 4. Flange Orientation 5.5 Install Access Valve Bolt the access valve to the mounting flange using the gasket, studs and nuts provided. Verify that the access valve is properly tightened to the mounting flange, because beyond this point it will not be serviceable without depressurizing the line. 5.5.1 Horizontal Pipes Orient the valve such that the valve stem is parallel with the centerline of the pipe (Figure 5). 5.5.2 Vertical Pipes Orient the valve such that the valve stem is perpendicular with the centerline of the pipe (Figure 5). Gap (1/16 [1.55mm] Typical) Tack weld Protect threads Complete weld Access Valve Stem Parallel to Center Line Access Valve Stem 90 to Center Line 90 Horizontal Orientation Vertical Orientation Figure 5. Access Valve Designs, materials, weights and performance ratings are approximate and subject to change without notice. 7

5.6 Drill Hole in Pipe With the access valve in the full open position, install an appropriate Hot Tap Drilling Machine (Figure 6) and drill a hole in the pipe (hole sizes per chart below). Follow the instructions given by the Hot Tap Drilling Machine. Sensor Size V400D-10 V400D-15 Hole Diameter 1 [25mm] 1 ½ [38mm] After the hole is completely drilled, retract the Hot Tap Drilling Machine. Shut off the access valve prior to removal of the Hot Tap Drilling Machine. Figure 6. Hot Tap Drilling Machines 5.7 Mount Sensor Assembly to Access Valve Orient the sensor such that the arrow labeled FLOW on the instrument head is in the direction of the flow in the pipe within 3 (orientation per Figure 7). Bolt the access nipple to the access valve using the gasket, studs and nuts provided. 8 Designs, materials, weights and performance ratings are approximate and subject to change without notice.

5.8 Vent Access Valve to Verify No Leaks are Present With the instrument valves shut, slowly crack open the access valve and verify that there are no process fluid leaks. If leaks are present, shut off the access valve and tighten the leaky joint. 5.9 Grease Drive Rod High temperature grease has been applied to the threaded rod at the factory. Verify the threaded rod is adequately greased prior to inserting the sensor. If necessary, smear grease on the threaded drive rod. A high temperature grease should be used on all steam applications and for temperatures above 200 F. Grease should be applied prior to subsequent insertions and retractions. 5.10 Insert Verabar Sensor Assembly Warning: The flow rate must be decreased to the amount stated on the Verabar nameplate: the maximum insertion/withdrawn DP/flow limit. The Verabar should be oriented such that the arrow on the head is pointing in the direction of the flow. Completely open the access valve. Then, using either drive nut, insert the sensor. The tip of the sensor should completely bottom on the opposite end of the pipe. Continue to insert the sensor until firm resistance is met. This will occur when the sensor plate is approximately 2 [51mm] from the top of the packing gland. Thread the jam nuts toward the threaded bushings. The jam nuts should press tightly against the threaded bushings. This will lock the drive rods in place and maintain the sensor position in the pipe. Vertical Pipe Orientations Direction of Flow Direction of Flow Direction of Flow Direction of Flow Horizontal Pipe Orientations Figure 7. Orientation of Flow Arrow Designs, materials, weights and performance ratings are approximate and subject to change without notice. 9

Verabar is now properly installed (Figure 8) Instrument Head Sensor Plate Sensor Bushing Cover Tube Drive Nut Packing Bolts Packing Gland Jam Nut Threaded Drive Rod Threaded Bushing Access Nipple Access Valve Stop Nut Mounting Flange Sensor Figure 8. Installed V400D (Double Rod) Section 6 Periodic Maintenance The assembly should be periodically checked. Verify that no leaks are present. The jam nuts and packing bolts should be tight. Section 7 Sensor Removal Procedure Shut off instrument valves Reduce flow rate below the maximum insertion/withdrawn DP/flow limit stated on the Verabar nameplate. Loosen jam nuts. Using either drive nut, retract the sensor until the stop nuts and jam nuts are pressing against the threaded bushings. Completely shut off the access valve. Slowly crack open one of the Verabar instrument valves and bleed off any remaining pressure contained in the access nipple. The sensor assembly can now be removed. 10 Designs, materials, weights and performance ratings are approximate and subject to change without notice.

VERIS, Inc. Limited Warranty and Remedy VERIS, Inc. ( VERIS ) warrants to the original user of those products supplied by it and used in the service and in the manner for which they are intended shall be free from defects in material and workmanship for a period of five (5) years from the date of installation, but not longer than 63 months from the date of shipment from the VERIS factory, unless a Special Warranty Period applies, as noted below. This warranty does not extend to any product that has been subject to misuse, neglect or alteration after shipment from the VERIS factory. Except as may be expressly provided in a written agreement between VERIS and the user, which is signed by both parties, VERIS DOES NOT MAKE ANY OTHER REPRESENTATIONS OR WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. The sole and exclusive remedy with respect to the above limited warranty or with respect to any other claim relating to the products or to defects or any condition or use of the products supplied by VERIS, however caused, and whether such claim is based upon warranty, contract, negligence, strict liability, or any other basis or theory, is limited to VERIS repair or replacement of the part or product, or, at VERIS option, to repayment of the purchase price. In addition to replacing any part of parts found to VERIS satisfaction to be defective, VERIS will pay the cost of shipment of both the defective part to the VERIS plant and the replacement part to the original user. As a condition of enforcing any rights or remedies relating to VERIS products, notice of any warranty or other claim relating to the products must be given in writing to VERIS: (i) within 30 days of last day of the applicable warranty period, or (ii) within 30 days of the date of the manifestation of the condition or occurrence giving rise to the claim, whichever is earlier. IN NO EVENT SHALL VERIS BE LIABLE FOR SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING, BUT NOT LIMITED TO, LOSS OF USE OR PROFITS OR INTERRUPTION OF BUSINESS. The Limited Warranty and Remedy terms herein apply notwithstanding any contrary terms in any purchase order or form submitted or issued by any user, purchaser, or third party and all such contrary terms shall be deemed rejected by VERIS. Special Warranty Periods are as follows: Electronic components, including without limitation, differential pressure transmitters, multivariable transmitters, flow computers, rate or totalizer displays: one (1) year from the date of installation, but not longer than 15 months from the date of shipment from the VERIS factory. Designs, materials, weights and performance ratings are approximate and subject to change without notice. 11

V400D VERIS Verabar (Double Rod) Installation and Maintenance Manual Designs, materials, weights and performance ratings are approximate and subject to change without notice. Armstrong International - VERIS Flow Measurement Group 5820 Glacier Way, Frederick, CO 80205 - USA Phone: 303-652-8550 Fax: 303-652-8552 armstronginternational.com 168-EN Printed in U.S.A. - 3/4/16 2016 Armstrong International, Inc.