INSTRUCTION, HALDEX PUMP LVS KIT P/N

Similar documents
INSTRUCTION, LVTS KIT, GPTLR KIT P/N

INSTRUCTION, GPT LOW VOLTAGE THERMAL SWITCH (LVTS) INSTALLATION KIT P/N

INSTRUCTION, TRAIL CHARGER KIT P/N

INSTRUCTIONS, ME2 BACKUP BAR KIT

INSTRUCTIONS, C2 TORSION SPRING REPLACEMENT

INSTRUCTION, BMR STREET-SIDE CONTROL

INSTRUCTION, GPT HAND PUMP KIT (BUCHER PUMP) INSTALLATION

INSTRUCTION, BMR AUXILIARY CONTROL

INSTRUCTION, GPT HAND PUMP KIT INSTALLATION GPT KIT P/N

INSTRUCTIONS (DROP PIN KIT FOR REPLACEMENT CABLE)

INSTRUCTION PLASTIC BATTERY BOX & CHARGER KIT

INSTRUCTIONS, FLASHING LIGHT INSTALLATION KIT

INSTRUCTION, TE-33 DUAL STEP KIT

INSTRUCTION, GPTLR POWER DOWN HAND PUMP KIT

M APRIL 2012 INSTALLATION MANUAL DMD-22 & DMD-33

INSTRUCTION, GPT HOSE RETROFIT KIT

INSTRUCTIONS, NISSAN TITAN TRUCK INSTALLATION KIT (C2 PICKUP LIFTGATES)

INSTRUCTION, CURRENT GPT HOSE RETROFIT KIT

INSTRUCTIONS, (FORD) SUPER DUTY INSTALLATION KIT (C2 PICKUP LIFTGATES)

INSTRUCTIONS, RA ROLLER REPLACEMENT

INSTRUCTIONS, (FORD) SUPER DUTY INSTALLATION KIT (C2 PICKUP LIFTGATES)

M REV. F AUGUST 2014 INSTALLATION MANUAL

INSTALLATION MANUAL DMD-22 & DMD-33

INSTRUCTION, DODGE TRUCKS INSTALLATION KIT (C2 LIFTGATES)

INSTALLATION MANUAL RA-35 & RA-45 M REV. D SEPTEMBER 2017

INSTRUCTIONS, RAM DUAL REAR WHEEL TRUCKS INSTALLATION KIT (C2 LIFTGATES)

TE-20 & INSTALLATION MANUAL M REV. F SEPTEMBER 2015

INSTRUCTIONS, SLEEVED CABLE KITS BMRA (INCLUDES BMRA-CS) KIT P/N

RCM-1250 C RCM-1250 C AB RCM-1600 RCM-1600 C AB

INSTALLATION MANUAL M REV. G AUGUST 2016

Instruction Sheet Kit Number:

VISOR AUDIO KIT P/N , APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Verify accessory fitment at Polaris.com.

REAR ROOF SPEAKER KIT

Accessory Harness & Bracket Kit

Ref Qty Part Description Part Number -1- Kit ( ) Contents:

M REV. B AUGUST 2010 INSTALLATION MANUAL GPTWR-3

P/N Rev 01 04/14-1- NOTE: If you are ordering hinges for your rear doors, order and/or

INSTALLATION & OWNER S MANUAL

Z-Gate Universal Shifter

M JULY 2017 GPTLR Liftgate www. maxonlift.com PRODUCTS, TUK-A-WAY GPTLR Maintenance Manual PRODUCT DOCUMENTATION PARTS PORTAL TUK-A-WAY GPTLR

M SEPTEMBER 2017

M REV B SEPTEMBER 2017

INSTALLATION MANUAL TE-33, TE-33L & TEWR-33 M REV. K DECEMBER 2016

M REV. D APRIL 2008 INSTALLATION MANUAL GPTLR-25, GPTLR-33, GPTLR-44, & GPTLR-55

850 TETHER SWITCH KIT

M REV. B FEBRUARY 2016

Technical Support (707)

DOOR KIT P/N , APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Verify accessory fitment at Polaris.com.

M REV. A APRIL 2008 INSTALLATION MANUAL

PRODUCT DOCUMENTATION PARTS PORTAL RAILIFT & DMD MAXON

TCI FastGate Shifter Installation Instructions

REARVIEW MIRROR AND BACKUP CAMERA KIT

GENUINE PARTS INSTALLATION INSTRUCTIONS

INSTALLATION & OWNER S MANUAL

M REV. C AUGUST 2008

Cantilever Series Mounting Instructions Chevy Express (AD) present

Cantilever Series Mounting Instructions Ram Promaster Extended Body (AH) Present

3 WRX/STI TURBO INLET HOSE

GENUINE PARTS INSTALLATION INSTRUCTIONS

M REV. C AUGUST 2017

RANGER 900 POWER STEERING KIT

650 Series Cargo Van Lift Mounting Instructions Ford Transit (Standard Roof) 2015-Present

2-Fryer Battery Wiring Restraint Kit Fryer Battery Wiring Restraint Kit Fryer Battery Wiring Restraint Kit

FOR APPROVAL ONLY. Snowmobiles WARNING PARTS TO BE INSTALLED

INSTALLATION & OWNER S MANUAL

650 Series Cargo Van Lift Mounting Instructions Fullsize Ford 1992-Present

Service Bulletin DIS185SSI4F Air Compressor Multiple Component Update

INSTALLATION INSTRUCTIONS SEMI-HIDDEN WINCH MOUNT Part Number:70005 Application: Ford Super Duty

MODEL NO & UP MODEL NO & UP MODEL NO & UP MODEL NO & UP

INSTALLATION INSTRUCTIONS

E-Z POWER TONNO Installation Instructions Full Size Ford & GM Pick Up 6 1/2 Ft. Box

Installation Instructions Unimatic Shifter

Assembly Instructions

Service Procedure Note Note Note

REF QTY PART DESCRIPTION PART NUMBER

FOR APPROVAL ONLY. Snowmobiles WARNING PARTS TO BE INSTALLED

SINGLE ACCENT LIGHT KIT

AUDIO KIT P/N APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Verify accessory fitment at Polaris.com.

Part Name/Description Part Number Quantity Instruction Kit Metalfor Flow Sensor

M REV. L AUGUST 2012

OUT FRONT ELECTRIC HYDRAULIC (W/E-47H) FOR STRAIGHT TRIPEDGE PLOWS (PULL AWAY MOUNTINGS)

Cantilever Series Mounting Instructions Fullsize Sprinter Van (US) WB (AB) present

Wiring Assembly Instructions Section 5 P/N CASS P/N 1899AS RG316 P/N CASS P/N 1899AS RG316

M REV. A DECEMBER 2016

Retriever 360G/P. 5/92 revised 2/01 FORM NUMBER

Engineered to Ride, Built to last

VW/AUDI MK7 VEHICLES

RMK HANDLEBAR KIT P/N ; ; APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Verify accessory fitment at Polaris.com.

TOYOTA TUNDRA TVIP V4 Preparation

Installation Instructions Unimatic Shifter

This information covers procedures for replacing the sealant for the crankshaft cover on the Volvo D16F engine.

GENUINE PARTS INSTALLATION INSTRUCTIONS

JD TRIPLE EGRESS TRIPLE EGRESS SECTION

BD Transmission Cooler Dodge (68RFE, 518, 47RH, 47RE & 48RE) Ford (All) & Chevy (Allison) Transmissions

ELECTRIC START KIT KIT P/N

OPERATOR ADAPTER ABBSV

FOR APPROVAL ONLY. Snowmobiles WARNING PARTS TO BE INSTALLED

INSTALLATION INSTRUCTIONS RDO 2904 POWER DOOR OPERATORS FULL SIZE GMC VAN, REAR KIT # 01240

Replacing a Gun RTD. Instruction Sheet P/N B. 1. Introduction. Using this Instruction Sheet

CONNECTOR INFORMATION

Transcription:

LIFT CORPORATION Sht. 1 of 11 DSG# M-06-33 Rev. - Date: 12/17/07 INSTRUCTION, HALDEX PUMP LVS KIT P/N 267923-01 MALE BULLET LVS WIRE HARNESS P/N 267924-01 QTY. 1 LOW VOLTAGE SWITCH (LVS MODULE) P/N 906530-01 QTY. 1 SHRINK TUBING, 1/4 x 2 LG P/N 250673-01 QTY. 1 LVS INSTRUCTION DECAL P/N 265923-02 QTY. 1 SCREW, PAN HEAD, 1/4-20 X 3/4 LG P/N 900002-1 QTY. 2 LOCK NUT, NYLON 1/4-20 P/N 901000 QTY. 2 FLAT WASHER, 1/4 P/N 902013-09 QTY. 2

LIFT CORPORATION Sht. 2 of 11 DSG# M-06-33 Rev. - Date: 12/17/07! WARNING To prevent personal injury and equipment damage, make sure power is disconnected at the battery while installing electrical parts. 1. Remove nut from positive (+) battery terminal connector. Disconnect the fused power cable (FIG. 2-1). Reinstall nut. POSITIVE (+) BATTERY FUSED POWER CABLE BOLT NUT DISCONNECTING FUSED POWER CABLE FIG. 2-1 2. Unlatch pump box cover (FIG. 2-2). Open the pump box cover to gain access to wiring connections (FIG. 2-2). LATCH (2 PLACES PUMP BOX COVER OPENING PUMP BOX COVER (SINGLE PUMP SHOWN) FIG. 2-2

LIFT CORPORATION Sht. 3 of 11 DSG# M-06-33 Rev. - Date: 12/17/07 3. Mark 2 holes on the outside of the pump box for each LVS module. (See FIG. 3-1 for single pump and FIG. 3-2 for dual pump.) Use a 17/64 bit to drill the 2 holes. 1-1/2 1-3/16 3-11/16 (MIN.) 3-3/4 (MAX.) MARKING THE MOUNTING HOLES FOR LVS #1 (SINGLE & DUAL PUMP, LH SIDE SHOWN) FIG. 3-1 1-3/16 1-1/2 3-11/16 (MIN.) 3-3/4 (MAX.) MARKING THE MOUNTING HOLES FOR LVS #2 (DUAL PUMP ONLY, RH SIDE SHOWN) FIG. 3-2

LIFT CORPORATION Sht. 4 of 11 DSG# M-06-33 Rev. - Date: 12/17/07 4. Attach LVS module (Kit item) to the inside wall of pump box. (See FIG. 4-1 for single pump and FIG. 4-2 for dual pump.) LVS #1 LOCK NUT SCREW FLAT WASHER LOCK NUT ATTACHING LVS #1 TO WALL OF PUMP BOX (SINGLE PUMP SHOWN) FIG. 4-1 LVS #1 LOCK NUT LVS #2 SCREW FLAT WASHER SCREW FLAT WASHER ATTACHING LVS #1 & LVS #2 TO WALLS OF PUMP BOX (DUAL PUMP SHOWN) FIG. 4-2

5. Connect LVS wiring harness (Kit item) to LVS module. (See FIG. 5-1 for single pump and FIG. 5-2 for dual pump.) LIFT CORPORATION Sht. 5 of 11 DSG# M-06-33 Rev. - Date: 12/17/07 NOTE: MAXON recommends using dielectric grease on all electrical connections. LVS HARNESS LATCH CATCH CONNECTORS CONNECTING LVS HARNESS TO LVS #1 (SINGLE PUMP SHOWN) FIG. 5-1 LVS HARNESS LVS HARNESS CATCH LVS #1 LATCH CONNECTORS LATCH LVS #2 CATCH CONNECTORS CONNECTING LVS HARNESSES TO LVS #1 & LVS #2 (DUAL PUMP SHOWN) FIG. 5-2

LIFT CORPORATION Sht. 6 of 11 DSG# M-06-33 Rev. - Date: 12/17/07! CAUTION Route electrical wires clear of the pump box cover and any sharp edges. Avoid making sharp bends in wiring. Connect wiring only as shown in the instructions that follow. 6. Cut the WHITE wire from the ring terminal connected to terminal D on the solenoid switch (FIG. 6-1). Next, strip 1/4 insulation from the white wire. Crimp the white wire to the male bullet terminal connected to the white wire on the LVS wire harness (FIG. 6-1). D WHITE WIRE (PUMP WIRE HARNESS) MALE BULLET WHITE WIRE FEMALE BULLET RED WIRE GREEN WIRE RING (CUT FROM WHITE PUMP WIRE) STARTER SOLENOID CONNECTING WHITE WIRE ON THE PUMP HARNESS TO WHITE WIRE ON LVS HARNESS (SINGLE PUMP SHOWN) FIG. 6-1

LIFT CORPORATION Sht. 7 of 11 DSG# M-06-33 Rev. - Date: 12/17/07 CAUTION To prevent damage to metal case starter solenoid, hold bottom terminal nut securely when loosening and tightening top terminal nut. Do not over-tighten the terminal nuts. For the 5/16 load terminals, torque nuts 35-40 lbs.-in. Torque the nuts on #10-32 control terminals 15-20 lbs.-in. 7. Connect LVS wire harness to starter solenoid as shown in FIG. 7-1. HEX NUT & FLAT WASHER (REMOVE/REINSTALL IN 3 PLACES) B D GREEN WIRE (PUMP WIRE HARNESS) RED WIRE GREEN WIRE RING WITH WHITE WIRE STUB (REMOVE & DISCARD) C GROUND (-) (GROUND WIRE) A CONNECTING LVS RED, GREEN & BLACK WIRES TO STARTER SOLENOID (SINGLE PUMP SHOWN) FIG. 7-1

LIFT CORPORATION Sht. 8 of 11 DSG# M-06-33 Rev. - Date: 12/17/07 NOTE: To install LVS #2 in a dual pump system, do steps 8 and 9. For a single pump system skip these steps and continue with step 10. 8. Cut the WHITE wire from the ring terminal connected to terminal D on the PUMP #2 starter solenoid (FIG. 8-1). Next, strip 1/4 insulation from the white wire. Crimp the white wire to the male bullet terminal connected to the white wire on the LVS wire harness (FIG. 8-1). D RED WIRE GREEN WIRE RING (CUT WHITE WIRE ON STARTER SOLENOID) STARTER SOLENOID WHITE WIRE (PUMP WIRE HARNESS CUT FROM D ) WHITE WIRE FEMALE BULLET MALE BULLET CONNECTING WHITE WIRE ON THE PUMP HARNESS TO WHITE WIRE ON LVS HARNESS (DUAL PUMP SHOWN) FIG. 8-1

LIFT CORPORATION Sht. 9 of 11 DSG# M-06-33 Rev. - Date: 12/17/07 CAUTION To prevent damage to metal case starter solenoid, hold bottom terminal nut securely when loosening and tightening top terminal nut. Do not over-tighten the terminal nuts. For the 5/16 load terminals, torque nuts 35-40 lbs.-in. Torque the nuts on #10-32 control terminals 15-20 lbs.-in. 9. Connect LVS wire harness to starter solenoid as shown in FIG. 9-1. HEX NUT & FLAT WASHER (REMOVE/REINSTALL IN 3 PLACES) B D RED WIRE GREEN WIRE RING WITH WHITE WIRE STUB (REMOVE & DISCARD) C GROUND (-) A (GROUND WIRE) CONNECTING LVS RED, GREEN & BLACK WIRES TO STARTER SOLENOID (DUAL PUMP SHOWN) FIG. 9-1

LIFT CORPORATION Sht. 10 of 11 DSG# M-06-33 Rev. - Date: 12/17/07 CAUTION For cover gasket to seal correctly, each LVS decal must be attached clear of the gasket sealing surface. NOTE: LVS instruction decals must be attached to the inside of the pump box cover & must be readable with cover open. 10. Attach each LVS instruction decal (FIG. 10-1) to the inside of the pump box cover (See FIG. 10-2 for single pump and FIG. 10-3 for dual pump). LVS INSTRUCTION DECAL LVS INSTRUCTION DECAL FIG. 10-1 PUMP BOX COVER DECAL ATTACHED TO PUMP BOX COVER (SINGLE PUMP SHOWN) FIG. 10-2 LVS INSTRUCTION DECAL PUMP BOX COVER DECAL ATTACHED TO PUMP BOX COVER (DUAL PUMP SHOWN) FIG. 10-3

LIFT CORPORATION Sht. 11 of 11 DSG# M-06-33 Rev. - Date: 12/17/07 11. Remove nut from positive (+) battery terminal connector. Reconnect the fused power cable to positive (+) battery terminal connector (FIG. 11-1). Reinstall and tighten nut. NUT POSITIVE (+) BATTERY FUSED POWER CABLE BOLT RECONNECTING FUSED POWER CABLE FIG. 11-1 12. Use the LVS instruction decal (FIG. 11-2) to ensure LVS & Liftgate function correctly. 13. Close pump box cover when installation and LVS check are completed. LVS INSTRUCTION DECAL FIG. 11-2