AGELKOM CAP04V-9 Plasma and Oxy Fuel Torch height control for sheet metal cutting machines Height Sensor & Controller

Similar documents
AGELKOM CAP04 Plasma and Oxy Fuel Torch height control for sheet metal cutting machines Height Sensor & Controller

AGELKOM CAP04 Plasma and Oxy Fuel Torch height control for sheet metal cutting machines Height Sensor & Controller

TRAC-3 TENSION READOUT AND CONTROL

User's Manual O

17429X.00 SERIES MODELS:

MPT SERIES OPERATING MANUAL. Caution: To Operate this controller safely, use the Safe Operating Area Design Tool Online at

APPLICATION AND SWITCH ORDERING GUIDE

LNII Series Motor and Drives

Controlled Ferroresonant Ballast (CFB) Generation #3. Manual

Fig.306F (DN50-150) Pressure Independent Control Valve (PICV)

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (0-10VDC Input Version)

BLDC SPEED CONTROL INSTRUCTION MANUAL Low voltage Brushless DC control

BLDC SPEED CONTROL INSTRUCTION MANUAL Line voltage Brushless DC control

Ultrasonic Sensor U-B

EG1065X. Compatible with Barber Colman* Dyn1-1065X series * Use for reference purpose only and not a genuine Barber Colman product.

715B CONTROL SERIES. Instruction Manual Line Voltage DC Brushless Motor Control CONTROLS. Phone (317) Fax (317)

DMX-A2-DRV Integrated Advanced Step Motor Driver

DENISON HYDRAULICS Jupiter 500 Driver Card Series S

HASTINGS INSTRUMENTS. AVG and AVC MODULE

ESC2301. Universal Electronic Governor Controller Operation Manual

700B CONTROL SERIES. Instruction Manual Low Voltage DC Brushless Control CONTROLS. Phone (317) Fax (317)

Installation Instructions for LED Timing Light

Models: User s Manual. Pulse-Width Modulated, Adjustable Speed Drives for DC Brush Motors

ADVR-12. Hybrid Universal Analog Digital Voltage Regulator Operation Manual

LTX RF LEVEL SENSOR. Instruction Manual

G213V STEP MOTOR DRIVE REV 7: March 25, 2011

FT-1005 Air Volume/Velocity Transducer. Operation & Maintenance Manual. Engineered for accuracy, applicability, durability and simplicity

AVR Hybrid Universal Analog Digital Voltage Regulator Operation Manual

DO NOT INSTALL, REMOVE, OR REWIRE THIS EQUIPMENT WITH POWER APPLIED.

1260 Infinity II Degasser User Manual. 5 Maintenance

Hoffman Controls. Installation & Operating Instructions. General. Installation. Determining Damper Shaft Rotation. Stop Pin Installation

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

DPS Telecom Your Partners in Network Alarm Management

EG3000. Generator Electronic Governor Controller Operation Manual

Spray Height Controller

Automatic Sliding Door Retrofit Drive Assembly. Installation Manual DoorControlsUSA.com

STANDARD AND GROUND SWITCHED APPLICATIONS

Damper Actuator Installation

EG1069X. Generator Electronic Governor Controller Operation Manual

Installation & Operation Manual

Features Block Diagram Specifications Typical Wiring Diagram Connection and Adjustment Locations...3 4

65E CONTROL SERIES CONTROLS. Instruction Manual. For DC Input Variable Speed Controls. P.0. Box W. 106th Street Zionsville, Indiana 46077

CN0055 & CN0055B DC to DC NEGATIVE RESISTANCE SPEED CONTROL

B-PC20 Power Close Module

INSTRUCTION MANUAL MODEL PS VDC POWER SUPPLY

Product Guide: Series III Pump Control Board Set (RoHS)

Electronic Proportional (EP) Control for Medium Duty Piston Pumps

Ultrasonic Two-Wire Point Level Control

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

INSTRUCTION MANUAL. A battery protector for vehicles with equipment that Is operated with the engine not running. MODEL# INPUT: 12 Volts D.C.

SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator.

Kelly HSR Series Motor Controller with Regen User s Manual V 3.3. Kelly HSR Opto-Isolated Series Motor Controller with Regen.

RBD Series. Installation and Maintenance Manual. An Altra Industrial Motion Company

Continental Hydraulics Installation Manual CEM-AA-A

730 CONTROL SERIES. Instruction Manual CONTROLS. Low Voltage DC Brushless Control. Phone (317) Fax (317)

G203V / G213V MANUAL STEP MOTOR DRIVE

ACCU-CAST POWER FLOAT INSTALLATION INSTRUCTIONS

Tension Control System MCS-166, MCS-203, MCS-204

USER MANUAL MODELS NRG02-D240AC-4Q NRG02-D240AC-4Q-PCM NRG05-D240AC-4Q NRG05-D240AC-4Q-PCM NRG10-115AC-4Q NRG10-115AC-4Q-PCM

ADVANCED PID TROUBLESHOOTING

EGG 101L INTRODUCTION TO ENGINEERING EXPERIENCE

TROUBLESHOOTING GUIDE FOR HEAT PUMP BOOSTERS MODELS: HPB11, HPB15, & HPB22

KL-8070D. Fully Digital Stepping Driver. Table of Contents 1. Introduction, Features and Applications...1 Introduction...1 Features...

CNC Router Parts CNC Router Parts 2.2 kw Plug and Play Spindle / VFD System CRP800 Retrofit Guide

MDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

CV - 6SL INSTRUCTION MANUAL 6000W POWER SUPPLY

DC3E Non-Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC M/N DC3N-12D AI M/N DC3N-12D-4X-010-AI

Technical Information and Diagnostic Guide RestStar Use this guide with 5700XE RestStar Unit. Western Star 5700XE.

WDC CONTROL SERIES. Instruction Manual. Variable Speed DC Control

220v Inverter Board Testing. Evaluation

Induction Power Supplies

Overview of operation modes

PALLET MASTER (PMD) OPERATING INSTRUCTIONS

5001TCP SPEED CONTROLLER

Troubleshooting Bosch Proportional Valves

I N C O R P O R A T E D

Thermal Mass Flow Meter (Analog)

ATP-2040 Electric Damper Actuator/Transmitter

TECHNICAL DATASHEET#TD1516AX 3 AMP SOLENOID DRIVER

STEPPER-BLOCKplus. Manual. Version: 2.0 As of: 06/2002 Author: Edmund Burger &RPSDFW6WHSSHU'ULYHU IRU3KDVH6WHSSLQJ0RWRUV. Main. Status-LED.

APEM SERIES - POTENTIOMETER JOYSTICKS TWO STANDARD MOUNTING OPTIONS LOW CURRENT DRAIN IP65 ABOVE PANEL.

CRECOMZR054B00 CRECOMZR055B00. VERTICAL AND HORIZONTAL ECONOMI$ER2 ACCESSORY MEDIUM ROOFTOP UNITS 15 to 27 1/2 TONS WARNING TABLE OF CONTENTS

Wiring diagrams on page 29 are for reference only. For detailed vehicle wiring refer to Navistar documents.

Versatile and Powerful

Installation and Operating Manual

CP-9301 CP Application. Features. Applicable Literature. Electronic Actuator Drives General Instructions

ESD5500E Series Speed Control Unit

AIRBAG SYSTEM (DIAGNOSTICS)

MI0559A OXY-BEVEL OPERATIONS MANUAL: Oxy-fuel contouring beveling head with manual tilt function.

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

400W Solar Charger Maximum Power Point Tracker

5001TCP SPEED CONTROLLER

DC Variable Speed Drive Panel

TELEDYNE. PB 4213 June JUDSON TECHNOLOGIES A Teledyne Technologies Company TELEDYNE JUDSON TECHNOLOGIES TC8 TEMPERATURE CONTROLLERS

Incremental encoders Solid shaft with clamping or synchro flange pulses per revolution programmable

CONTROL FEATURES AVAILABLE OPTIONS

ZG-JSL, ZG-JSLA Jackshaft Retrofit Linkage For AF, NF, LF, NMX and AMX Series Actuators

Cover. L5v2 Plug-In Conversion Module(PCM) Diagnostic Trouble Codes

Electronic Proportional (EP) Control for Heavy Duty Series 2 Piston Pumps Model 33

Explanation 1 Input External Switch 2 Input Hipot Safety Switch

Transcription:

AGELKOM CAP04V-9 Plasma and Oxy Fuel Torch height control for sheet metal cutting machines Height Sensor & Controller 9 PIN D-SUB INTERFACE CAP 04 CAPACITIVE HEIGHT CONTROLLER IN POSITION CABLE FAULT Description: RING The metal sensor ring is connected to the CAP04 via a 90 cm long 75 ohms low capacitance coaxial cable. There is a 2 size for Sensor Ring. The Plasma Ring ID is 34 mm and OD is 47 mm. Sensing height of the ring should be between 1,5 to 9 mm above the plate. The Fuel Ring ID is 50 mm and OD is 69 mm. Sensing height of the oxy ring should be between 7 to 35 mm above the plate The ring must be insulated from all conductive parts of the cutting torch. BNC ELECTRONICS: The connection of supply and outputs to the CAP04V-9 is via 9 core screened cable with D-SUB 9 pin connector. The supply is nominal 24VDC and the consumption current is less than 150mA. Do not use same power supply with motors. The all outputs are at normally low, 15V level during in active and drive up to 15mA.. These outputs can directly drive LED or Opto Coupler. Due to current limiting, there is no need voltage divider for 12 and 5 volts input range of your breakout board if inputs are opto coupler isolated. Touch output can be adjusted internal trimpot as a minimum height. It allows NULLING the height, if such feature required. Voltage Control inputs are floating, with opto- coupler isolated. Inputs can be driven 0-10V analogue output, however due to electrical noisy environment input has threshold level about 2-3V and range is 3-10V. It is also possible with external potentiometer (1K linear) as a voltage divider for adjusting the height manually. GROUNDING: The diecast box must be grounded. Usually the sensor is bolted to the housing of torch lifter and must be connected via thick wire 10mm² to System Ground to have a sufficient ground connection. Use STAR type grounding. Interface cable shield should be connected at system side. See the page Agelkom CAP04-V-9P Manual 1

Common Point for Adjustment Black bead 9 PIN D-SUB for COIL adj. GAP ADJUSTM ENT CCW Turn - off the LED COIL Adjust 1 volt at Orange bead Narrow Wide 6. Reconnect the drive system. Height / Voltage Adjust 10V (white bead) at 10V Control Input HEAD BNC IN POS CABLE : 1. Apply 10V DC to Height Control inputs. Adjust Height/Voltage trimpot until 10V reading at WHITE bead. Manually adjust the torch lifter, so the ring is about 50 mm above the plate. 2. Disable the drive system (e.g. electrically or mechanically disconnect motor). 3. Activate CAP04 and monitor up and down output. At this point (GREEN) LED must be on, if not internal coil adjustment needed. (Refer Internal Coil Adjustment Section). 4. Decrease the distance between sensing ring and plate and verify that (AMBER) LED is ON. 5. Disconnect BNC connector and verify that CABLE (RED) LED is ON. The correctly adjusted sensor should activate outputs within +/- 0.05 mm at 1.5 mm above the plate and up to +/- 0.2 mm at 35 mm. with two sensor. Internal Coil Adjustment: (if it is necessary) It is operating point adjustment. It is not sensitivity adjustment. 1. Do not apply Height Control Voltage. This is for maximum height. 2. In Home position of your Z axis LED must be ON, if not: Remove the front panel. Use plastic screw driver. Gently adjust of the internal coil of CAP04 sensor and observe down output is activated in your HOME position (or sufficiently high above the plate.) If LED is activated instead of readjust the core of the coil. 3. Start slowly to decrease the distance between sensing ring and the plate to the cutting height of say 3mm and verify that LED is ON. If not, readjust the coil. 4. If you need to change the cable between the unit to sensor ring, internal coil should be re-adjusted. You must use 90 cm long sensor cable and the type is RG59 Important: Do not turn more then ¼ tour CW or CCW and do not apply force to the CORE of the internal coil. The CORE is easily broken. Window Adjustment: There is small amount of GAP (window) between and. Also GAP could be adjusted with internal trimpot. Turning CW of trimpot makes gap wider. Increased cutting height will result in a wider the GAP. Agelkom CAP04-V-9P Manual 2

Touch (Down Limit) Adjustment: After all adjustment was finished, you can start to adjust Down Limit potentiometer, adjust this multiturn trimmer potentiometer (turn CCW) until LED is OFF Afterwards, close the sensor ring until it touches the plate or insert paper between sensor ring and plate (cutting material). Turn CW until LED is ON APPLICATION: During plasma cutting, sensor ring and plasma torch are in the same height. This will allow to use output as a collision detection means. If any fault occurs, the output activate automatically. During thick plate cutting, dross may touch the sensor ring and the torch head lifted. To avoid this situation correct your cutting parameters for less dross. CAP04 can be used with voltage controlled Height Control System. The two systems are OR ed. Height / Voltage Adjust 10V (white bead) at 10V Control Input Common Point to Black bead 9 PIN D-SUB 10V (white bead) Test Point CON NECTOR for COIL adj. GAP CCW Turn - off the LED Narrow Wide PWM Disable Jumper IN POS CABLE COIL 1 volt at Orange bead NOT Turn more than1mm HEAD BNC Height Voltage Adustment as follows: 67mm approx. Apply these input 10VDC and adjust trimmer potentiometer until to read at WHITE BEAD about 10V. Reduce control voltage about 3 volts and measure 13.67V at same test point. Between 0 to 3Volts, controlling is disabled for the noise margin. If no voltage applied, the same voltage appear about 13.67V. This is the Maximum Height Level Please do not change until it is necessary. Agelkom CAP04-V-9P Manual 3

Simplified typical connection of CAP04-V shown below. POWER +24VDC POWER 0V - CABLE SHIELD POWER SPLY / SYSTEM GROUND AGELKOM CAPACITIVE CAP04 V-9pin PIN NUMBER 3 6 5 2 1 9 8 7 STANDARD CABLE COLORS RED + 24v GREEN YELLOW BROWN WHITE IN POSITION GREY HEIGHT V - PURPLE HEIGHT V + BLUE 0V Breakout Board I/O board Analog Out 0-10VDC User defined PC Port# and pin# To PC, Port 2, pin # Torch Down input To PC, Port 2, pin # Torch Up input To PC, Port 2, pin # User Defined input To PC Port 2, pin # Probe input To PC Port 2, pin # Spindle Output To PC Port Ground 9 Pin D-Sub Female Connector 9 Pin Terminal Board Connection + 24V From CAP04V-9 Mach 3 Configuration Test: Unplug the Cap04 and press the buttons and observe that your inputs respond correctly. IN POSITION 0V Of Supply and common GND of,inputs. REMOTE HEIGHT V + REMOTE HEIGHT V - Technical Specifications: Supply: Nominal 24VDC 100mA, Max: 30VDC Min: 18VDC Current: Less than 100mA Protection: Against supply reverse voltage. All Outputs: Normally high at 15V, 15mA with current limiter resistor. Can be drive opto-coupler directly Sensor Cable: 90cm Length, Type RG59 Agelkom CAP04-V-9P Manual 4

Internal Coil Adjustment: Mount CAP04 and Sensor Head with Sensor Ring to your machine. Keep Sensor Ring to Working Plate distance at maximum (at least 10cm). Important: Do not turn fully CW or CCW and do not apply force to the CORE of the internal coil. The CORE is easily broken. Use plastic screw driver. Adjustment range is narrow, within 1mm mowing is sufficient to adjustment Correct Adjustment Point Voltage Fully CCW CW Coil 1 HEIGHT CONTROL KNOB TURN FULLY CCW 4 ADJUST INNER COIL TO MINUMUM VOLTAGE 1-3 volts 3 CONNECT DVM + TO TEST POINT HOOK With Orange Bead GAP COIL HEAD 2 CONNECT DVM to HOOK with Black Bead or (-) of your Supply Smoothly close some metal plate (say 20cm x 20cm) to sensor ring and observe that voltage increase (never decrease) come to closer. Agelkom CAP04-V-9P Manual 5

Correct Adjustment Point Wrong Adjustment Point Sensig Height Fully CCW Down Led is ON CW Coil Up Led is ON MOUNTING Dimensions are in mm. Case Size 116*65*31 Two mounting holes are shown in red GROUNDING Machine Chassis To System & Power Supply Box Use STAR type Ground Connection Use thick wire (10mm²) Agelkom CAP04-V-9P Manual 6

Mounting Details 67mm approx. 47 mm dia. 69 mm dia. Agelkom CAP04-V-9P Manual 7