HS1E Series Full Size Solenoid Locking Switches

HS1B R - R. Door Interlock Switches. HS1B Series. HS1B Series Full Size Interlock Switch. Part Number. HS1B features: Part Number Key.

HS2B N B - R. Door Interlock Switches. HS2B Series. Full Size Interlock Switch. Part Number. HS2B features: Part Number Key.

HS1B Series Full Size Interlock Switch. GS-ET-15 BG standard in Germany. Part Number Key

HS1E Series Full Size Interlock Switch with Locking Solenoid

HS1C Series Full Size Interlock Switch with Locking Solenoid. GS-ET-15 BG standard in Germany. HS1C Series Functionality

Door Interlock Switches

HS6B Series Subminiature Interlock Switch

Safety Products. Safety Products. HS5E Series. HS5E Series Miniature Solenoid Locking Switch

HS5E Series Miniature Solenoid Locking Switches

Door Interlock Switches

HS6E - L 4 4 B 01 - G

HS6B Series Sub-Miniature Interlock Switch. Direct Opening

Solenoid Locking Safety Switches

HS1C Interlock Switches with Solenoid

HS1L Interlock Switches with Solenoid

HS6E Subminiature Interlock Switches with Solenoid. Double Installation. Part Number. Cable Length (+) ( ) A2 A1

Solenoid Locking Safety Switches

HS1E-K Interlock Switches with Solenoid (3-circuit)

HS5D Miniature Interlock Switches

HS1C-P Interlock Plug Unit with Door Lock

HS1L Interlock Switches with Solenoid

HS1L Interlock Switches with Solenoid

HS5D Miniature Interlock Switches

Door Interlock Switches

HS1E Interlock Swithes with Solenoid

Section. Safety Products Selection Guide...B-2

HS5E Miniature Interlock Switches with Solenoid

Door Interlock Switches

Interlock Switches. Safety. Selection Guide HS6B Subminiature HS5D Miniature HS2B Full Size...

Head Removal Detection Function for Safer Performance

Standard Interlock Safety Switches

Standard Interlock Safety Switches

SG-B1 SERIES / SG-A1 SERIES

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

HS5E Miniature Interlock Switches with Solenoid

HS5E Miniature Interlock Switches with Solenoid

HS6E Subminiture Interlock Switches with Solenoid

HS6B HS6E. Angled connection. cable. Compact with three poles of contacts. (HS6B) Small interlock switch with five poles and solenoid.

ct O en n Tr ve Solenoid Indicator (1) TÜV rating AC V, 3A 3 Mounting Examples

NO NO NO. Standard Interlock Safety Switches HS6B. HS5E-K Key Locking Safety Interlock Switches

HS6B Subminiature Interlock Switches

Safety device new products line up. Introducing a safety door switch with solenoid interlock that is among the world s thinnest*

Interlock Switches Interlock Plugs

Hinged Safety Door Switch

2 Specifications and Ratings. Applicable Standards. Operating Condition. Thermal Current Ith 10A Contact Ratings. Operating Speed

Safety Limit Switch

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

Miniature Switches & Pilot Devices

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Door Handle Gate System

Think Automation and beyond... IDEC Safety Interlock Switches

Manual Reset Limit Switch

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

D4DL. Guard Lock Safety-door Switch. Model Number Structure

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

Door Handle Gate System

Safety-door Switch. Ordering Information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Signaling Lights LD6A. LD6A LED SignaLight Towers Assembled Products. Unique Striped Design Improves Visibility

Enabling Switches. Safety. Selection Guide

XW Series E-Stops. Safety. Selection Guide ø22mm XW E-Stops

Oiltight Switches & Pilot Devices

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

D4BL. Guard Lock Safety-door Switch. Die-cast aluminum body Key holding force of 700 N. Model Number Structure. Model Number Legend Switch D4BL - K

Safety Control HR1S-AC. Safety Relay HR1S-AC

Cable length. 3: 3 m. 4: Adjustable mounting (vertical) 4: 3NC (slow action) 5: 5 m. (Slow-action) Horizontal 1 m D4GS-N1R D4GS-N2R D4GS-N3R D4GS-N4R

D4DL. Ordering Information. Compact Guard-locking Interlock Safety Door Switch. Model Number Legend Switches D4DL- -

Limit Switches with Positive Opening Mechanism

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

HS7A-DMC Non-contact Interlock Switches

D4JL/D4JL-SK40 CSM_D4JL_D4JL-SK40_DS_E_10_2

22mm XW E-Stops. UL File #E68961 CCC No Specifications

D4BS CSM_D4BS_DS_E_8_4

HL (AZH) Limit Switches

HL (AZH) LIMIT SWITCHES

D4D-N. Safety Limit Switch. Small, Economical Switch Featuring a Positive Opening Mechanism and CE Marking. H Contacts opened by positive opening

Switches & Pilot Devices

Safety-door Switch D4NS. Model Number Structure. Model Number Legend

Safety switches with separate actuator

D4B-N. uce. Safety Limit Switch. Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications

LR-LX-LK-LW Safety Switches with separate actuator

XA Series Emergency Stop Switches (w/removable Contact Block)

RU Series Universal Relays

LJASeries. Limit Switches with Positive Opening Mechanism

D4DS. Safety-Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. H Conforms to EN (TÜV) standards.

D4NH. Safety-door Hinge Switch. Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment

D4GS-N CSM_D4GS-N_DS_E_7_2

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

D4BL. Guard Lock Safety-door Switch

D4SL. Safety Interlock Switches. Compact 6-Contact Guard Lock Safety-Door Switch NEW! Specifications. Standards and EC Directives

DL (AZD1) Mini Limit Switches

PRODUCT SPECIFICATION. Stack Lights. Series.

ø8 A8 Series Miniature Control Units

Safety Limit Switch

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

22mm XW E-Stops. IEC , EN , JIS C , UL508, UL991, NFPA79, CSA C22.2 No. 14, GB

ø12 A2 Series Miniature Control Units

ED SERIES SAFETY LIMIT SWITCH

Transcription:

HSE Series HSE Series Full Size Locking Switches Overview X Series E-Stops HSE features: Basic unit and solenoid unit in one housing Plastic Housing: Light weight Ease of Wiring: All the terminal screws are M3.5 Available with a red or green indicator Choose from 4 circuit confi gurations When mounting the actuator on a movable door, and the switch on a machine body, the door can be mechanically locked when closed Greater Safety: The door is unlocked by a solenoid lock-release signal from a PLC or other source after the machine has stopped In the event of power failure or for machine maintenance, the door can be unlocked using a special tool Flexible Installation: The actuator can be accessed from two directions HSE Series Functionality Conduit Port Use IP67 conduit or gland. EN088 EN60947-5- IEC60947-5- GS-ET-5 BG standard in Germany Certificate No. 00050030545656 Direct Opening Action Double Insulation Contact Mechanism LED Indicator (green or red) Terminal Block (M3.5) Enabling Switches Straight Actuator (Zinc Diecast) Angle Adjustable Actuator (for hinged doors) Right-angle Actuator Terminal Block for Pilot Light (M3.5) Two Actuator Entry Slots AS-Interface Safety at Work Barriers 384 www.idec.com

HSE Series Part Numbers Actuator Retention Force 500N (when locked) Lock Mechanism Spring Lock Contact Configuration circuit: NC + NC circuit: NO/NO circuit: NC + NC circuit: NO circuit: NC + NC circuit: NO + NC circuit: NC + NC circuit: NC. Key wrench for TORX screws (HS9Z-T) is supplied with the interlock switch.. Specify color code in place of k in the part number. G: green, R: red 3. Actuator is not supplied with the interlock switch, and must be ordered separately. 4. TORX is a registered trademark of Camcar Textron. 3 4 5 6 Indicator 7 the. 8 3 4 5 6 Indicator 7 8 the. 3 4 5 + 6 Indicator 7 the. 8 3 4 5 + 6 Indicator 7 the. 8 Conduit Port Size Actuator Keys & Accessories Item Part Number Description Item Part Number Description HS9Z-A HS9Z-A Straight Actuator (ly for sliding doors) Right-angle Actuator (ly for rotating doors) HS9Z-T HS9Z-P HS9Z-A3 Adjustable ActuatorHS9Z-KEY G/ G/ G/ G/ Indicator Key Wrench (included with switch) Conduit Opening Plug Replacement Manual Unlocking Key Model Manual Unlock Key Part Number HSE-40R With HSE-44R-k With HSE-40KR With With HSE-44KR-k HSE-40R With HSE-44R-k With HSE-40KR With With HSE-44KR-k HSE-40R With HSE-44R-k With HSE-40KR With With HSE-44KR-k HSE-340R With HSE-344R-k With HSE-340KR With With HSE-344KR-k Overview X Series E-Stops Enabling Switches Barriers AS-Interface Safety at Work USA: 800-6-IDEC Canada: 888-37-IDEC 385

HSE Series AS-Interface Safety at Work Barriers Enabling Switches X Series E-Stops Overview Specifications Conforming to Standards EN088, IEC60947-5-, EN60947-5-(TUV), ISO49, GS-ET-9 (BG), UL508, CSA C. No. 4 (c-ul) Applicable Use IEC6004-, EN6004- Operating Temperature 0 to +40 C (no freezing) Storage Temperature 40 to +80 C Operating Humidity 40-85% RH (no condensation) Altitude,000m maximum Rated Insulation Voltage (Ui) 300V (between LED or solenoid and ground: 60V) Impulse Withstand Voltage (Uimp) 4 kv (between LED or solenoid and ground:.5 kv) Insulation Resistance (measured with 500V DC megger) Electric Shock Protection Pollution Degree Degree of Protection Between live and dead metal parts: 00 MΩ minimum Between live metal part and ground: 00 MΩ minimum Between live metal parts: 00 MΩ minimum Between terminals of the same pole: 00 MΩ minimum Class II (according to IEC640) 3 (IEC60947-5-) IP67 (IEC6059) Vibration Operating Extremes 0 to 55 Hz, minimum (amplitude 0.35 mm) Resistance Damage Limits 50 m/sec (approx. 5G) Shock Resistance,000 m/sec (approx. 00G) Actuator Tensile Strength when Locked,500N minimum (per GS-ET-9) Actuator Operating Speed m/sec maximum Positive Opening Travel mm minimum Positive Opening Force 0N minimum Thermal Current (Ith) circuit: 0A, Auxiliary circuit: 3A Rated Operating Current (Ie) Operating Voltage (Ue) 30V 5V 50V Auxiliary AC DC AC DC Resistive load (AC) Inductive load (AC5) Resistive load (DC) Inductive load (DC3) Resistive load (AC) Inductive load (AC5) Resistive load (DC) Inductive load (DC3) 0A 0A Contact Gap circuit:.7 mm min., Auxiliary circuit:. mm min. Operating Frequency 900 operations/hour max. Mechanical Life,000,000 operations min. (at full rated load) 900 ops/hr (AC-/50V, 6A) Electrical Life 00,000 operations (rated load) Conditional Short-circuit Current 00A (per IEC60947-5-) Recommended Short Protection 50V, 0A fuse (Type D0 based on IEC6069-, 6069-) Unit Indicator Weight Operating Voltage Current Coil Resistance Pickup Voltage DropOut Voltage Allowable Voltage Insulation Class Operating Voltage Current Light Source Lens Color 4V DC 9mA 0Ω (at 0ºC) 0.5V maximum (at 0ºC).4 minimum (at 0ºC) 6.4V max (continuous) Class F 4V DC 0 ma LED lamp Red or Green ( mm dia. Lens) Approx. 500g 6A 3A 3A 0A 5A 0.9A 3A 0.9A 6A 3A 3A 3A Part Number Key HSE - 4 4 K R - R Indicator Color: R (Red) G (Green) Manual Unlock Key K (with actuator) 0 (without actuator) Indicator Rated Voltage 4 (4V DC) Blank (without indicator) Code Auxiliary Blank: NC + NC NO/NO : NC + NC NO : NC + NC NC + NC 3: NC + NC NC 386 www.idec.com

HSE Series Application Examples and Diagrams HSE-4 ( : NC-NC, Auxiliary : NO/NO) Switch/Door Status Door Diagram Status Status Status 3 Status 4 Unlocked Manually Machine ready to operate Machine cannot be started Machine cannot be started Machine cannot be started Machine cannot be started de-energized de-energized energized de-energized de-energized the the the the the 3-4: Closed 3-4: Open 3-4: Open 3-4: Closed 3-4: Open Aux. -: Open -: Closed -: Closed -: Closed -: Closed 5-6: OFF 5-6: ON 5-6: ON 5-6: OFF 5-6: OFF HSE-4 ( : NC-NC, Auxiliary : NO) Status Status Status 3 Status 4 Unlocked Manually Switch/Door Machine ready to operate Machine cannot be started Machine cannot be started Machine cannot be started Machine cannot be started Status de-energized energized energized de-energized de-energized Door Diagram the the the (Note) the the 3-4: Closed 3-4: Open 3-4: Open 3-4: Open 3-4: Open Aux. -: Open -: Open -: Closed -: Closed -: Open 5-6: OFF 5-6: ON 5-6: ON 5-6: OFF 5-6: OFF. : used to enable the machine to start only when the main circuit is closed.. Auxiliary : used to indicate whether the machine circuit or door is open or closed. 3. Terminals 7 and 8 are used for the LED indicator, and are isolated from solenoid and door status. Overview X Series E-Stops Enabling Switches Barriers AS-Interface Safety at Work USA: 800-6-IDEC Canada: 888-37-IDEC 387

HSE Series Application Examples and Diagrams, continued Overview HSE-4 ( : NC+NC, Auxiliary : NC+NC) Switch/Door Status Status Status Status 3 Status 4 Unlocked Manually Machine ready to operate Machine cannot be started Machine cannot be started Machine cannot be started Machine cannot be started de-energized energized energized de-energized de-energized Door X Series E-Stops Diagram Enabling Switches the the the the the 3-4: Closed 3-4: Open 3-4: Open 3-4: Open 3-4: Open Aux. -: Closed -: Open -: Open -: Open -: Open 5-6: OFF 5-6: ON 5-6: ON 5-6: OFF 5-6: OFF HSE-34 ( : NC+NC, Auxiliary : NC) Status Status Status 3 Status 4 Unlocked Manually Switch/Door Machine ready to operate Machine cannot be started Machine cannot be started Machine cannot be started Machine cannot be started Status de-energized energized energized de-energized de-energized Door Barriers Diagram (Note) AS-Interface Safety at Work the the the the the 3-4: Closed 3-4: Open 3-4: Open 3-4: Open 3-4: Open Aux. -: Closed -: Closed -: Open -: Open -: Closed 5-6: OFF 5-6: ON 5-6: ON 5-6: OFF 5-6: OFF. : used to enable the machine to start only when the main circuit is closed.. Auxiliary : used to indicate whether the machine circuit or door is open or closed. 3. Terminals 7 and 8 are used for the LED indicator, and are isolated from solenoid or door status. 388 www.idec.com

HSE Series Dimensions (mm) HSE with indicator - using 500N operating force Horizontal Mounting Straight Actuator HS9Z-A 0 6.5 ± 8.5 ± 54.3 (RP) 45.4 39. 68.8 (RP) 49.5 -M6 Actuator Mounting Holes RP: Actuator Mounting Reference Position Slot Plug (supplied) (Note) 0 40 35 5.5 4 4 4 57.5 04 88 33 3. 6 89 Note: Plug the unused atuator entry slot using the slot plug supplied with the interlock switch. 3.5 6.3 9 Actuator Cover HS9Z-A Actuator 5 45 63 Vertical Mounting Right-angle Actuator HS9Z-A 89 3-M5 Screw Mounting Hole Layout.0 7.5 ± 46.5 (RP) 6 3.5 9.5 ± 6 (RP) Actuator Cover HS9Z-A Actuator Overview X Series E-Stops Enabling Switches Barriers AS-Interface Safety at Work USA: 800-6-IDEC Canada: 888-37-IDEC 389

HSE Series Accessories Overview Straight Actuator (mainly for sliding doors) HS9Z-A -M6 Screws R3. 40 9 9.3 49.3 9. 43 Actuator Mounting Holes 7.4 Actuator Cover (red) X Series E-Stops 4. Right-angle Actuator (mainly for hinged doors) HS9Z-A 0.5 7.4 -M6 Screws 4.5 40 9. 43 *After installing the actuator, remove the actuator cover. Actuator Mounting Holes R3. 90 Actuator Cover (red) 4. Adjustable Actuator Enabling Switches The actuator angle is adjustable (0 to 0 ) for hinged doors. The minimum radius of the door opening can be as small as 00mm. For HS/HS Series (HS9Z-A3) (Note) Actuator Stop Film (attached) 8 9. 44 58 7 Barriers 58 5 0 R3. Angle Adjustment Screw (M3 hexagon socket head screw) Door hinge -M6 Screws Actuator Mounting Holes 30 AS-Interface Safety at Work 33 max. () 0 All dimensions in mm. 390 www.idec.com

HSE Series Accessories, continued Actuator Angle Adjustment Using the screw (M3 hex socket head screw), the actuator angle can be adjusted (refer to the dimensional drawing). Adjustable angle: (0 ) to 0 The larger the adjusted angle of the actuator, the smaller the applicable radius of the door opening. of Hinged Door When using the interlock switch for a hinged door, refer to the minimum radius of doors shown below. For the doors with small minimum radius, use angle adjustable actuators (HS9ZA3 or HS9Z-A3S). Note: Because deviation or dislocation of hinged door may occur in actual applications, make sure of the correct operation before installation. HS9Z-A Actuator When the door hinge is on the extension line of the interlock switch surface: 30 mm When the door hinge is on the extension line of the actuator mounting surface: 40 mm 30 mm 400 mm HS9Z-A Actuator After installing the actuator, open the door. Then adjust the actuator so that its edge can be inserted properly into the entry slot of the safety switch. Recommended tightening torque: 0.8 N-m (approx. 8.0 kgf-cm) After adjusting the actuator angle, apply loctite or the like to the adjustment screw so as to prevent its loosening. When using the HS9Z-A3 Angle Adjustable (vertical) Actuator When the door hinge is on the extension line of the interlock switch surface: 50 mm When the door hinge is on the extension line of the actuator mounting surface: 80 mm HS9Z-A3/A3S Actuator Overview X Series E-Stops Enabling Switches Barriers AS-Interface Safety at Work USA: 800-6-IDEC Canada: 888-37-IDEC 39

Precautions Safety Precautions In order to avoid electric shock or a fi re, turn the power off before installation, removal, wire connection, maintenance, or inspection of the switch. If relays are used in the circuit between the safety switch and the load, consider degrees of the danger and use safety relays, since welded or sticking contacts of standard relays may invalidate the functions of the safety switch. Regardless of door types, do not use the safety switch as a door stop. Install a mechanical door stop at the end of the door to protect the safety switch against excessive force. Do not apply excessive shock to the switch when opening or closing the door. A shock to the door exceeding,000 m/sec (approx. 00G) may cause the contacts of the switch to chatter, and a malfunction of the switch may occur. For connection of wires, unscrew the cover. Unnecessary loosening of other screws may cause a malfunction of the switch. For Rotating Head Directions The heads of the HS5E/HS5B can be rotated in 90 increments after removing the 4 screws on the corners of the head. Prevent entry of foreign objects into the switch during removal of the head. Tighten these screws with torque designated in the instruction sheet. Improper torque may cause errors. Factory Setting Head can be rotated. of Hinged Doors When using the interlock switch on hinged doors, refer to the minimum radius of doors shown below. When using on doors with small minimum radius, use the angle adjustable actuator (HS9Z-A55). Wire Connection The HSB has 3 conduit ports, which are closed as a part of the molded switch housing. Make an opening for wire connection by breaking one of the conduit-port knockouts on the switch housing using a screwdriver. When breaking the conduit port, take care not to damage the contact block or other parts inside the switch. Operation Precautions - for all series HS5E/HS5B Precautions Do not place a PLC in the circuit between the safety switch and the load. The safety security can be endangered in the event of a malfunction of the PLC. Do not disassemble or modify the switch. It may cause a breakdown or an accident. Prevent foreign objects such as dust and liquids from entering the switch while connecting conduit or wiring. If the operating atmosphere is contaminated, use a protective cover to prevent the entry of foreign objects into the switch through the actuator entry slots. Entry of a considerable amount of foreign objects into the switch may affect the mechanism of the switch and cause a breakdown. Do not store the switches in a dusty, humid, or organic-gas atmosphere. Note: Because deviation or dislocation of hinged doors may occur in actual applications, make sure of the correct operation before installation. When using the HS9Z-A5 Actuator When the door hinge is on the extension line of the interlock switch surface: 70 mm 90 mm When door hinge is on the extension line of the actuator mounting surface: 30 mm HSB Precautions 60 mm Cracks or burrs on the conduit entry may deteriorate the housing protection against water. When changing to another conduit port, close the unused opening with an optional plug (Part No. HS9Z-P). Overview X Series E-Stops Enabling Switches Barriers AS-Interface Safety at Work USA: 800-6-IDEC Canada: 888-37-IDEC 397

Precautions HSE Precautions Overview Wire Connection Make an opening for wire connection by breaking one of the conduit-port knockouts on the switch housing using a screwdriver. Before breaking the knockout, temporarily remove the connector-fi xing lock nut from the switch.. This unlocking method is intended for an escape from a machine when a person is locked in. For access to the unlocking entry, an access hole should be opened on the mounting panel. When opening the hole, apply proper protection against water or other foreign objects.. Caution: After the unlocking operation, put the screw back into the unlocking entry for safety. When breaking the knockout, take care not to damage the contact block or other parts inside the switch. Cracks or burrs on the conduit entry may deteriorate the housing protection. X Series E-Stops When changing to the other conduit port, close the unused opening with an optional plug (accessory). Plug Type No. HS9Z-P Screwdriver Unlock Normal Position Unlock Manual Unlocking Position Manual Unlocking Remove the screw located on the unlocking entry at the side of the switch using the key wrench included with the switch. Then insert a small screwdriver into the switch to push the lever inside of the switch toward the indicator until the actuator is unlocked (refer to the diagram on the right). Insert a small screwdriver into the elliptical hole on the back of the switch, then push the lever inside of the switch toward the indicator until the actuator is unlocked (refer to the diagram on the right). M5 3.5 6 89 Enabling Switches Regardless of door type, do not use the safety switch as a locking device. Install a locking device independently, for example, using a metal latch (also applicable to HSE). The safety switch cover can be only removed with the special key wrench supplied with the switch or with the optional screwdriver (also applicable to HSB and HSE). HSC Precautions Barriers AS-Interface Safety at Work Remove the screw located on the unlocking entry at the side of the switch using the key wrench included with the switch. Then insert a small screwdriver into the switch to push the lever inside of the switch toward the indicator until the actuator is unlocked (refer to the diagram on the right). Caution: After the unlocking operation, put the screw back into the unlocking entry for safety. Screwdriver 398 www.idec.com

Precautions Operation Precautions Applicable Crimping Terminals Applicable Connectors (As shown below) (Refer to the Crimping Terminal or shown in the drawing below.) HSC Terminals No. to 6: Use solid or stranded wires only (crimping terminals not applicable). Terminals No. 7 and 8: Crimping Terminal Ground Terminal: Crimping Terminal HSB Ground Terminal: Crimping Terminal Other Terminals: Crimping Terminal HSB, HS5B, and HSE Crimping Terminal 3.6 min. 3.5 max. ø3.6 min. 6.9 max. Crimping Terminal Use an insulation tube on the crimping terminal. Wire Approx. 4mm Insulation Tube 3.5 min. 3.8 max. ø4. min. 7.6 max. Crimping Terminal Crimping Terminal Installation Examples (see the diagrams below) Mounting on Sliding Doors Door HS9Z-A Actuator Door Stop Mounting on Hinged Doors HS9Z-A Actuator Latch HS9Z-A Actuator Use connectors which maintain the IP67 protection. Applicable Connector Dimensions Flex Conduit: VF03 (Japan Flex) www.nipolex.co.jp Steel Connector (G/): ALC-03 (PF3.5): RBC-03PG3.5 9 mm max. G/ Recommended Screw Tightening Torque HSC: 5.0±0.5 N-m (approx. 50±5 kgf-cm) (4 or 6 pcs of M5 hex socket head cap screws) HSB: 5.0±0.5 N-m (approx. 50±5 kgf-cm) ( or 4 pcs. of M5 hex socket head cap screws) HSB: 5.0±0.5 N-m (approx. 50±5 kgf-cm) ( pcs of M5 hex socket head cap screws) HS5B: 4.0±0.4 N-m (approx. 40±4 kgf-cm) ( pcs of M4 hex socket head cap screws) HSE: 5.0±0.5 N-m (approx. 50±5 kgf-cm) (4 or 6 pcs of M5 hex socket head cap screws) Actuator (HS9Z-A/A) 5.0±0.5 N-m (approx. 50±5 kgf cm) ( pcs. of M6 hex socket head cap screws) Actuator (HS9Z-A5/A5).0±0. N-m (approx. 0± kgf cm) ( pcs of M4 hex socket head cap screws).0±0. N-m (approx. 0± kgf cm) ( pcs of M4 Phillips screws) The screws are supplied by the user. Applicable Wire Size 30 mm max. HSC: 0.5 to 0.75 mm (Terminals No.,, 5 to 8).0 to.5 mm (Terminals No.3, 4, and grounding terminal) HS5B: 0.5 to.5 mm HSE: 0.5 to.5 mm Overview X Series E-Stops Enabling Switches Barriers AS-Interface Safety at Work USA: 800-6-IDEC Canada: 888-37-IDEC 399

Precautions Overview Actuator Angle Adjustment Using the screw (M3 hex socket head screw), the actuator angle can be adjusted (refer to the dimensional drawing). Adjustable angle: (0 ) to 0 The larger the adjusted angle of the actuator, the smaller the applicable radius of the door opening. After installing the actuator, open the door. Then adjust the actuator so that its edge can be inserted properly into the entry slot of the safety switch. Recommended tightening torque: 0.8 N-m (approx. 8.0 kgf-cm) After adjusting the actuator angle, apply loctite or the like to the adjustment screw so as to prevent its loosening. X Series E-Stops of Hinged Door When using the interlock switch on hinged doors, refer to the minimum radius of doors shown below. When using on doors with small minimum radius, use the angle adjustable actuator (HS9Z-A55). Note: Because deviation or dislocation of hinged doors may occur in actual applications, make sure of the correct operation before installation. When using the HS9Z-A5 Actuator When the door hinge is on the extension line of the interlock switch surface: Horizontal Swing 50 mm Vertical Swing 70 mm 90 mm Enabling Switches 70 mm When door hinge is on the extension line of the actuator mounting surface: 30 mm 60 mm When using the HS9Z-A55 Angle Adjustable Actuator When door hinge is on the extension line of the interlock switch surface: 50 mm When door hinge is on the extension line of the actuator mounting surface: 70 mm 50 mm 70 mm Actuator Angle Adjustment for the HS9Z-A55 Using the angle adjustment screw, the actuator angle can be adjusted (see fi gures on page 370. Adjustable angle: 0 to 0 The larger the adjusted angle of the actuator, the smaller the applicable radius of the door opening. After installing the actuator, open the door. Then adjust the actuator so that its edge can be inserted properly into the actuator entry slot of the interlock switch. After adjusting the actuator angle, apply Loctite to the adjustment screw so that the screw will not loosen. Barriers AS-Interface Safety at Work Use a cable gland with a degree of protection IP67 G/, PG3.5, M0 9 max. When Using Flexible Conduits (Example) Flexible conduit example: VF-03 (Nihon Flex) 30 max. Applicable Cable Glands When Using Multi-core Cables (Example) all dimensions in mm Conduit Port Size Plastic Cable Gland Metal Cable Gland G/ RLC-03 (Nihon Flex) PG3.5 RBC-03PG3.5 (Nihon Flex) M0 RLC-03EC0 (Nihon Flex) Conduit Port Size Plastic Cable Gland Metal Cable Gland G/ SCS-0* (Seiwa Electric) PG3.5 ST3.5 (K-MECS) M0 ST-M0X.5 (K-MECS) ALS-6** (Nihon Flex) ABS-**PG3.5 (Nihon Flex) ALS-**EC0 (Nihon Flex) Different cable glands are used depending on the cable sheath outside diameter. When purchasing a cable gland, confirm that the cable gland is applicable to the cable sheath outside diameter. When using a /-4NPT cable gland, use the HS5B interlock switch with M0 conduit port (Part No.: HS5B-***BM) together with an adapter (Part No.: MA-M/NPT 0X.5 540-00, K-MECS) and a gasket (Part No.: GP M0, K-MECS). Install a gasket between the interlock switch and the adapter. Apply sealing tape between the cable gland and the adapter to make sure of IP67 protection for the enclosure. 400 www.idec.com