Replacement s List 700024100 Revision C 03/2018 Daikin McQuay Large Capacity Fan Coil Direct Drive HCDB, HHDB 06-20 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com
Contents s List Revision History... 3 Nomenclature Serial... 4 Model... 4-7 Coils Section Sizes 06, 08... 8 Sizes 12, 16, 20... 9 Unit Assembly PSC Units... 10 ECM, VSP Units Diagrams... 11 Size 06, 08, 12 Components... 12 Size 16, 20 Components... 13 Drain Pan & Drip Tray... 14 Control Box... 15 Field Installed Accessories... 16-18 Critical s List... CPL1 Fan Coil, HCDB, HHDB 06-20 Design 1 Rev. C 03/18 RPL 7000241 /Page 2
s List Revision History Rev. Date New A 02/13 New 09/15 All Pages- Update to Daikin Format. Delete sheet metal & add footnote #1 to contact Daikin. Update diagrams and drain pans part numbers. Page 5- Change Codes- C32 Add ECM. Pages 12, 15, 18 & 21- Add ECM motor & diagrams. Pages 22-24 Updated field installed accessories. CPL1- Change to Daikin Format. Add ECM motor. B 03/16 Page 22- Add Control Box page. Add EVO Control Boards p/ns 910161413 & 910160028, Transformer p/n 910116204, and Toggle Switch p/n 106616101. CPL1- Rev Change only. C 03/18 Combined HCDB & HHDB Unit Assy into Sizes 06-12 & 16-20. Pages 10, 12,13 Change 3-spd sw p/n 038255700 to Kit p/n 107112101. Add capacitor cap p/n 04015720. Numerous changes to the blower housings & wheels. Page 16- Add TStat, BACnet p/n 250803500. Page 17- Change heating coil p/n 065532400 to 910210499. CPL1- Update revision. Daikin Applied, 13600 Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN 55440 (763) 553-5330 Fan Coil, HCDB, HHDB 06-20 Design 1 Rev. C 03/18 RPL 7000241 /Page 3
Nomenclature Serial AUB U 12 03 35105 Plant Identification AUB = Auburn SLP= San Luis Potosi U= Unit Serial (build sequence) Week of Manufacture Year of Manufacture 11= 2011 12= 2012 etc. Model HC DB 1 06 A A G M Y YY C3122YS YY00YYY YY W1122YS Y 000 Code 01 02 03 04 05 06 07 08 09 10 11-16 17-21 22 23-27 28 29 YY R PSC S 3 Y D Y RD H BYY Y Y Y YY YY MBR Y YYYY Code 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 YYYY YYYY YY Y YYYYY Y YYY YY P I M1 YYY 00 YYY FS YY A Code 49 50 51-52 53 54-57 58 59-61 62 63 64 65 66-67 68 69 70 71 72 Code 01: Unit Type/Cabinet Type HC= Large Cap Horizontal Cabinet Fan Coil HH= Large Cap Horizontal Hideaway Fan Coil Code 02: Product Identifier Digit 1: Drive Type D= Direct Digit 2: Unit Configuration B= Blow Thru Code 03: Design Series 1= Design 1 Code 04: Unit Size 06= 600 CFM 08= 800 CFM 12= 1200 CFM 16= 1600 CFM 20= 2000 CFM Code 05: Voltage A= 115/60/1 C= 208/60/1 G= 230/60/1 J= 265-277/60/1 Coil Options Code 06: Coils- Fin Type A= Aluminum Code 07: Coils- Casing Material G= Galvanized Code 08: Coils- Air Vent M= Manual Code 09: Coils- Coating Code 10: Always YY Continued on the next page. Fan Coil, HCDB, HHDB 06-20 Design 1 Rev. C 03/18 RPL 7000241 /Page 4
Nomenclature Continued Primary Coil Code 11 to 16: Primary Coil C 3 12 2 Y S Connection Type S= Sweat Piping Package Connection Location 1= Left Hand 2= Right Hand Fins-per-inch 12= 12 FPI Rows 3= 3 Row 6= 6 Row Coil Type C= Chilled Water Only W= CW/HW 2- Pipe Preheat Coil Code 17 to 21: Preheat Coil YY 00 Y Y Y Connection Type Piping Package Connection Location Fins-per-inch 00= None Coil Type Y Code 22: Always YY Reheat Coil Code 23 to 27: Secondary Reheat Coil W1 12 2 Y S Connection Type S= Sweat Piping Package Connection Location 1= Left Hand 2= Right Hand Fins-per-inch 12= 12 FPI Coil Type W1= 1-Row Water (CW) W2= 2-Row Water (CW) S1= 1-Row Steam (CW) S2= 2-Row Steam (CW) Y (CW/HW) Code 28: Electric Heat Power Supply Code 29: Electric Heat Wattage 000= None Code 30: Always YY Code 31: Drain Pan A= Galvanized, LH Conn. (HH only) B= Galvanized, RH Conn. (HH only) C= Galvanized, LH Conn. w/drip Pan (HH only) D= Galvanized, RH Conn. w/drip Pan (HH only) E= Galvanized, LH Conn. w/drip Pan & Pipe Ext. (HC only) F= Galvanized, RH Conn. w/drip Pan & Pipe Ext. (HC only) G= Galvanized, LH Conn. w/secondary Drain Pan (HC only) H= Galvanized, RH Conn. w/secondary Drain Pan (HC only) J= Galvanized, LH Conn. w/pipe Ext. (HC only) K= Galvanized, RH Conn. w/pipe Ext. (HC only) L= SS, LH Conn. (HH only) M= SS, RH Conn. (HH only) N= SS, LH Conn. w/drip Pan (HH only) P= SS, RH Conn. w/drip Pan (HH only) Q= SS, LH Conn. w/drip Pan & Pipe Ext. (HC only) R= SS, RH Conn. w/drip Pan & Pipe Ext. (HC only) S= SS, LH Conn. w/secondary Drain Pan (HC only) T= SS, RH Conn. w/secondary Drain Pan (HC only) U= SS, LH Conn. w/pipe Ext. (HC only) V= SS, RH Conn. w/pipe Ext. (HC only) Code 32: Blower Motor PSC= PSC Motor ECM= ECM Motor VSP= VSP Motor YY Code 33: Discharge Conditions S= Standard Static Code 34: Motor Speed 3= 3 Speed Code 35: Motor Location Code 36: Motor Horsepower A= 1/4 HP (Qty= 1) B= 1/4 HP (Qty= 2) C= 1/3 HP (Qty= 1) D= 1/3 HP (Qty= 2) G= 3/4 HP H= 1.0 HP Code 37: RPM Selection Code 38: Return Air- Inlet 1st Digit- Plenum & R/A Location R= Rear (No Plenum) 2nd Digit- Type D= Duct Collar (No Plenum) Continued on the next page. Fan Coil, HCDB, HHDB 06-20 Design 1 Rev. C 03/18 RPL 7000241 /Page 5
Nomenclature Continued Code 39: Motor Connection H= Hard Wired Code 40: Starter- Disconnect- Controller Y Y Y Other Control Suppliers Control Type Disconnect- Starter B= 2 x 4 Junction Box (all wires routed to J-box) Y= No Controls- no wiring Code 41: Network communication Card Code 42: Programmability Code 43: Changeover Type Code 44: Switch System Y Code 45: Setpoint Adjustment Y Code 46: Fan Speed Control Digit 1: Speed Adjustment Type M= Manual Digit 2: Available Fan Speeds B= Off/Low/Med/High Digit 3: Mounting Location R= Remote Code 47: Future Use Only Code 48: Primary Coil Valve Y Y Y Y Actuator Input Control Type Unpowered Position Code 49: Preheat Coil Valve Y Y Y Y Actuator Input Control Type Unpowered Position Preheat Coil Valve Type Code 50: Reheat Coil Valve Y Y Y Y Actuator Input Control Type Unpowered Position Reheat Coil Valve Type Code 51: Future Use Only Code 52: Low Temperature Protection Code 53: Condensate Overflow Protection F= Float Switch Only (for field installation) Code 54: Discharge Air Thermistor Code 55: Smoke Input Code 56: Occupied/Vacant Control Input Code 57: Filter Status Primary Coil Valve Type Continued on the next page. Fan Coil, HCDB, HHDB 06-20 Design 1 Rev. C 03/18 RPL 7000241 /Page 6
Nomenclature Continued Code 58: Fan Status Code 59-61: Future Use Only YY Code 62: Cabinet Gauge SG= Standard Gauge Y Code 63: Cabinet Coating Type P= Premium Code 64: Cabinet Color C= Cupola White I= Antique Ivory Code 65: Cabinet Plenum Insulation YY= No Plenum M1= 1" Matte-Face Fiberglass C1= 1" Closed Cell Insulation Code 66-67: Future Use Only YY Code 70: Discharge Air- Outlet Digit 1: D/A Location F= Front Digit 2: Type A= Double Deflection Adjustable Grille D= Duct Collar S= Stamped Louver P= Open Code 71: Mixing- Fresh Air Damper Digit 1: Fresh Air Opening Location Digit 2: Damper Actuator Type Code 72: Filter A= 2" Throwaway Filter L= 2" MERV 8 Filter Code 73-74: Always YYYY Code 75: Agency Listing Code 76: Packaging Code 77: Warranty Code 78: Product Style/Quick Ship Code 68: Future Use Only 00= None Code 69: Future Use Only YY Fan Coil, HCDB, HHDB 06-20 Design 1 Rev. C 03/18 RPL 7000241 /Page 7
Coil Section Sizes 06, 08 600 Reheat Coil 500 Primary Coil Manual Air Valves Unit Size N/S Air Valve ALL 107264801 N/S= Not Shown on Diagram. Size 06 500 Primary Coil, 3 Row 048946110 Primary Coil, 6 Row 048948510 600 Reheat Coil, 1 Row 065531010 Reheat Coil, 2 Row 065531610 Size 08 500 Primary Coil, 3 Row 048946310 Primary Coil, 6 Row 048948710 600 Reheat Coil, 1 Row 065531110 Reheat Coil, 2 Row 065531710 Fan Coil, HCDB, HHDB 06-20 Design 1 Rev. C 03/18 RPL 7000241 /Page 8
Coil Section Sizes 12, 16, 20 Size 12 500 Primary Coil, 3 Row 048946510 Primary Coil, 6 Row 048948910 600 Reheat Coil, 1 Row 065531210 Reheat Coil, 2 Row 066531810 Size 16 500 Primary Coil, 3 Row 048946710 Primary Coil, 6 Row 048949110 600 Reheat Coil, 1 Row 065531310 Reheat Coil, 2 Row 065531910 Size 20 500 Primary Coil, 3 Row 048946910 Primary Coil, 6 Row 048949310 600 Reheat Coil, 1 Row 065531410 Reheat Coil, 2 Row 065532010 Fan Coil, HCDB, HHDB 06-20 Design 1 Rev. C 03/18 RPL 7000241 /Page 9
Unit Assembly PSC Units Cabinet/Chassis Components 72 68 66 See Fan Deck Detail 86 Fan Deck Detail Unit Sizes 66 Blower Housing Assy, PSC only 06, 08, 16 263012107 1 Blower Housing Assy, PSC only 12, 20 263012108 1 68 Wheel- Blower 06, 08, 16 802000037 1 Wheel- Blower 12, 20 018089000 1 72 Cutoff Plate 06, 08, 16 016156700 1 Cutoff Plate 12, 20 016156600 1 N/S Capacitor- 115V 06 910120040 1 Capacitor- 115V 08 910120042 1 Capacitor- 115V 12 910120044 1 Capacitor- 115V 16 910120042 2 Capacitor- 115V 20 910120044 1 Capacitor, 265V 06 910120041 1 Capacitor, 265V 08, 12 910120042 1 Capacitor, 265V 16, 20 910120042 2 N/S Cap, Capacitor 06, 08, 12 040157200 1 Cap, Capacitor 16, 20 040157200 2 N/S Bracket, Capacitor 06, 08, 12 049269701 1 Bracket, Capacitor 16, 20 049269701 2 86 Motor, 1/4 HP, 115/60/1 06, 08, 12 910101201 1 Motor, 1/4 HP, 265/60/1 06, 08, 12 049545900 1 Motor, 1/3 HP, 115/60/1 16, 20 910104181 2 Motor, 1/3 HP, 265/60/1 16, 20 049546000 2 N/S Wall Mtd, 3 Spd Fan Switch Kit ALL 107112101 1 N/S Junction Box, 4 X 4 x 1.5 ALL 802007362 1 N/S Junction Box, Cover ALL 000127300 1 N/S Cabinet/Chassis Components 1 1 1 N/S= Not Shown on Diagram. 1 Please contact Daikin with unit model and serial number for part numbers or cabinet/chassis components. Qty. Fan Coil, HCDB, HHDB 06-20 Design 1 Rev. C 03/18 RPL 7000241 /Page 10
Unit Assembly ECM, VSP Units Diagrams Sizes 06, 08, 12 Cabinet/Chassis Components 365 370 ECM Motor Detail Drain Pan Drip Tray See Fan Deck Detail 68 72 66 WARNING LABEL NP Motor Fan Deck Detail ECM Motor Nameplate 400 Sizes 16, 20 Cabinet/Chassis Components 365 370 400 Name Plate Drain Pan Drip Tray See Fan Deck Detail Single Shaft ECM Motor Dual Shaft ECM Motor with Name Plate Fan Coil, HCDB, HHDB 06-20 Design 1 Rev. C 03/18 RPL 7000241 /Page 11
Unit Assembly ECM, VSP Units Sizes 06, 08, 12 Unit Sizes 66 Blower Housing Assy, until 3/16 06, 08 263012107 1 Blower Housing Assy, until 3/16 12 263012108 1 Blower Housing Assy, Containment, 3/14/16 to 3/30/16 06, 08 910181705 1 Blower Housing Assy, Containment, 3/14/16 to 3/30/16 12 910181704 1 Blower Housing Assy, LH, 12/16 to 9/17 06, 08 263012124 1 Blower Housing Assy, LH, 12/16 to 9/17 12 263012123 1 Blower Housing Assy, LH, 9/17 & later 06, 08 263012125 1 Blower Housing Assy, LH, 9/17 & later 12 263012127 1 Blower Housing Assy, RH, 11/16 to 9/17 06, 08 263012122 1 Blower Housing Assy, RH, 11/16 to 9/17 12 263012121 1 Blower Housing Assy, RH, 9/17 & later 06, 08 263012128 1 Blower Housing Assy, RH, 9/17 & later 12 263012126 1 68 Wheel- Blower 06, 08 802000037 1 Wheel- Blower 12 018089000 1 72 Cutoff Plate 06, 08 016156700 1 Cutoff Plate 12 016156600 1 N/S Wall Mtd, 3 Spd Fan Switch Kit 06, 08, 12 107112101 1 N/S Junction Box, 4 X 4 x 1.5 06, 08, 12 802007362 1 N/S Junction Box, Cover 06, 08, 12 000127300 1 365 Arm, Motor Mount 06, 08, 12 668405401 3 370 Band, Motor Mount 06, 08, 12 802009140 1 N/S ECM Motor Drip Tray 06, 08, 12 910121480 1 N/S Cabinet/Chassis Components 06, 08, 12 1 1 400 ECM Motor & Program 2 See ECM Motor Nameplate 1 N/S= Not Shown on Diagram. 1 Please contact Daikin with unit model and serial number for part numbers or cabinet/chassis components. 2 The P/N for the ECM Motor is found on the Nameplate label (See illustration above). You may also contact Daikin with the unit model and serial number to get the ECM Motor part number. Qty. Fan Coil, HCDB, HHDB 06-20 Design 1 Rev. C 03/18 RPL 7000241 /Page 12
Unit Assembly ECM, VSP Units Sizes 16, 20 Unit Sizes 66 Blower Housing Assy, until 3/16 16 263012107 2 Blower Housing Assy, until 3/16 20 263012108 2 Blower Housing Assy, Containment, 3/14/16 to 3/30/16 Blower Housing Assy, Containment, 3/14/16 to 3/30/16 Qty. 16 910181705 1 16 263012107 1 20 910181704 1 20 263012108 1 Blower Housing Assy, LH, 12/16 to 9/17 16 263012124 2 Blower Housing Assy, LH, 12/16 to 9/17 20 263012123 2 Blower Housing Assy, LH, 9/17 & later 16 263012125 2 Blower Housing Assy, LH, 9/17 & later 20 263012127 2 Blower Housing Assy, RH, 11/16 to 9/17 16 263012122 2 Blower Housing Assy, RH, 11/16 to 9/17 20 263012121 2 Blower Housing Assy, RH, 9/17 & later 16 263012128 2 Blower Housing Assy, RH, 9/17 & later 20 263012126 2 68 Wheel- Blower, until 3/16 16 802000037 2 Wheel- Blower, until 3/16 20 018089000 2 Wheel- Blower, Containment, CW, 3/14/16 to 3/30/16 802000037 1 16 Wheel- Blower, Containment, CCW, 3/14/16 to 3/30/16 910120940 1 Wheel- Blower, Containment, CW, 3/14/16 to 3/30/16 018089000 1 20 Wheel- Blower, Containment, CCW, 3/14/16 to 3/30/16 910120941 1 Wheel- Blower, 12/16/9/17 16, 20 802000037 2 72 Cutoff Plate 16 016156700 2 Cutoff Plate 20 016156600 2 N/S Wall Mtd, 3 Spd Fan Switch Kit 16, 20 107112101 1 N/S Junction Box, 4 X 4 x 1.5 16, 20 802007362 1 N/S Junction Box, Cover 16, 20 000127300 1 365 Arm, Motor Mount 16 668405401 6 370 Band, Motor Mount 16 802009140 2 N/S ECM Motor Drip Tray 16, 20 910121480 1 N/S Bracket, Motor Mount 20 910151473 1 N/S Cabinet/Chassis Components 16, 20 1 1 400 ECM Single Shaft Motor & Program (size 16) 2 See ECM Motor Nameplate 2 ECM Dual Shaft Motor & Program (size 20) 2 See ECM Motor Nameplate 2 N/S= Not Shown on Diagram. 1 Please contact Daikin with unit model and serial number for part numbers or cabinet/chassis components. 2 The P/N for the ECM Motor is found on the Nameplate label (See illustration above). You may also contact Daikin with the unit model and serial number to get the ECM Motor part number. Fan Coil, HCDB, HHDB 06-20 Design 1 Rev. C 03/18 RPL 7000241 /Page 13
Unit Assembly Drain Pan & Drip Tray Model Drain Pan Unit Sizes 06 08 12 16 20 Drain Pan, LH HCDB 263012716 263012705 263012706 263012713 263012704 Drain Pan, RH HCDB 263012723 263012721 263012712 263012707 263012711 Drain Pan, SS, LH HHDB 263012734 263012720 263012719 263012722 263012725 Drain Pan, SS, RH HHDB 263012727 263012717 263012718 263012715 263012724 Drain Pan, LH HCDB 263012756 263012746 263012744 263012742 263012754 Drain Pan, RH HCDB 263012755 263012735 263012741 263012743 263012750 Drain Pan, SS, LH HHDB 263012757 263012751 263012737 263012736 263012745 Drain Pan, SS, RH HHDB 263012752 263012740 263012738 263012748 263012747 Secondary Drain Pan Model Unit Sizes 06 08, 12 16 20 Drain Pan, LH HCDB N/A 263005504 263005517 263005503 Drain Pan, RH HCDB 263005518 263005505 263005506 263005501 Drain Pan, SS, LH HCDB N/A 263005515 263005512 263005516 Drain Pan, SS, RH HCDB N/A 263005508 263005514 263005507 Drip Tray MODEL Drip Tray, LH HCDB 065853501 Drip Tray, RH HCDB 065853401 Drip Tray, SS, LH HCDB 910164189 Drip Tray, SS, RH HCDB 910164187 Drip Tray, LH HHDB 910164353 Drip Tray, RH HHDB 910164352 Fan Coil, HCDB, HHDB 06-20 Design 1 Rev. C 03/18 RPL 7000241 /Page 14
Control Box 218 216 230 295 Unit Sizes 06 08 12 16 20 216 Control Board, 4-Speed ECM Adjustible 910160028 1 1 1 1 1 218 Control Board, EVO Board, 2 Motors 910161413 1 1 230 Transformer, 115V 910116204 1 1 1 1 1 Transformer, 208/230V 910116202 1 1 1 1 1 Transformer, 265V 910116203 1 1 1 1 1 295 Switch, Toggle, 20A 106616101 1 1 1 1 1 Fan Coil, HCDB, HHDB 06-20 Design 1 Rev. C 03/18 RPL 7000241 /Page 15
Field Installed Accessories Unit Sizes Filters HCDB HHDB 12 Pack Individual 12 Pack Individual Filter, TA 06 106337201 060687107 107109512 065810404 Filter, TA 08 106337201 060687107 107109612 065810405 Filter, TA 12 106337201 060687107 107109712 065810406 Filter, TA 16 106337201 060687107 107109812 065810407 Filter, TA 20 106337301 000011800 107109912 065810408 Wall Thermostats 4" X 4" Adapter Plate For Wall Mtd. TStat 106510601 Digital, 24/115-277V, 2 Pos Valve, Staged Fan 107345336 Digital, 24/115-277V, 3 Speed, 2 Pos Valve, Valve Control or Fan Cycle 107345335 Digital, 2 or 4 Pipe, 24 Volt, 2 Pos Valve or 3 Wire Mod, 3 Speed Switch, ACO 107345301 Digital, 2 or 4 Pipe, 24V, 2 Pos or 3 Wire Mod Valve 107345245 Digital, 2 or 4 Pipe, 24V Proportional Valve 107014411 Remote Return Air Sensor- 60" Lead (used with 107014411) 107345501 Thermostat Kit 039398000 Thermostat Range Stop 107345320 TStat, 2 Pipe, No Speed Switch, 2 Pos Valve, Heat/Cool, MCO 107345303 TStat, 2 or 4 Pipe, 3 Speed Switch, 2 Pos Valve, Heat/Cool, MCO 107345302 TStat, 2 or 4 Pipe, 3 Speed Switch, 2 Pos Valve, Heat/Cool, ACO 107345304 TStat, 2 or 4 Pipe, No Speed Switch, 2 Pos Valve, Heat/Cool, ACO 107345305 T-Stat, Fan Coil BACnet 250803500 Fan Coil, HCDB, HHDB 06-20 Design 1 Rev. C 03/18 RPL 7000241 /Page 16
Field Installed Accessories Continued Miscellaneous Components Hanging Rails 107111302 Condensate Overflow Switch (Dry Contact) Kit 910118322 Perimeter Gasket, 60 Feet 106319601 Transformer, 75VA, 115/24V 106343701 Transformer, 25VA, 265V 107112301 Vibration Isolator Kit- contains R-I-S Isolators (4) 106319704 Heating Coil Kit Unit Sizes Kit P/N Coil only P/N Gasket P/N (Qty= 2) 1-Row Heating Coil Assy 06 065532400 065531010 021539902 1-Row Heating Coil Assy 08 065532500 065531110 021539902 1-Row Heating Coil Assy 12 065532600 065531210 021539902 1-Row Heating Coil Assy 16 065532700 065531310 021539902 1-Row Heating Coil Assy 20 065532800 065531410 021539902 2-Row Heating Coil Assy 06 065533000 065531610 021539902 2-Row Heating Coil Assy 08 065533100 065531710 021539902 2-Row Heating Coil Assy 12 065533200 065531810 021539902 2-Row Heating Coil Assy 16 065533300 065531910 021539902 2-Row Heating Coil Assy 20 065533400 065532010 021539902 Fan Coil, HCDB, HHDB 06-20 Design 1 Rev. C 03/18 RPL 7000241 /Page 17
Double Deflection Grille- HCDB Field Installed Accessories Continued Grilles and Duct Collars- HCDB Unit Sizes Double Deflection Grille 06 107108900 Double Deflection Grille 08 107107400 Double Deflection Grille 12 107107700 Double Deflection Grille 16 107108000 Double Deflection Grille 20 107108300 Stamped Grille- HCDB Stamped Grille Kit 06 107108700 Stamped Grille Kit 08 107107200 Stamped Grille Kit 12 107107500 Stamped Grille Kit 16 107107800 Stamped Grille Kit 20 107108100 Duct Collar- HCDB Duct Collar, 3/4" 06 107108800 Duct Collar, 3/4" 08 107107300 Duct Collar, 3/4" 12 107107600 Duct Collar, 3/4" 16 107107900 Duct Collar, 3/4" 20 107108200 Fan Coil, HCDB, HHDB 06-20 Design 1 Rev. C 03/18 RPL 7000241 /Page 18
Critical Daikin Applied OEM s Are What Your HVAC Unit Needs! Daikin Large Capacity Fan Coil Direct Drive McQuay Large Capacity Fan Coil Direct Drive HCDB, HHDB 06, 08, 12, 16, 20 Design 1 Critical Components Unit Sizes Voltage Fan Motor Motor, 1/4HP 06, 08, 16 115/60/1 910101201 Motor, 1/4HP 06, 08, 16 265/60/1 049545900 Motor, 1/3HP 12, 20 115/60/1 910104181 Motor, 1/3HP 12, 20 265/60/1 049546000 ECM & Program ALL ALL See motor nameplate Fan Housing and Wheel Fan Housing Assy, LH 06, 08, 16 N/A 263012125 Fan Housing Assy, RH 06, 08, 16 N/A 263012128 Fan Housing Assy, LH 12, 20 N/A 263012127 Fan Housing Assy, RH 12, 20 N/A 263012126 Wheel, Blower, CW 06, 08,16 N/A 802000037 Wheel, Blower, CW 12, 20 N/A 018089000 Wheel, Blower, CCW 16 N/A 910120940 Wheel, Blower, CCW 20 N/A 910120941 Call Your Local Daikin Applied s Distributor For All Your s Needs. To Locate A Distributor, Go To www.daikinapplied.com or Call 1-800-37PARTS 7000241 Rev. C 03/2018 CPL Page 1 of 1