ONSITE WASTEWATER TREATMENT SYSTEM Property Transfer Certification Instructions and Inspection Report

Similar documents
OSCAR- LOWeFLOW Treatment System Homeowner s Manual. January 2016

WSB clean: Installation Manual

Electric Service Conversion Overhead-to-Underground Xcel Energy Electric Connections. Minnesota North Dakota South Dakota

Commercial Fats, Oils & Grease Stephen Sealey

ORDINANCE NO BE ORDAINED BY THE CITY COUNCIL OF THE CITY OF TALLADEGA, ALABAMA, AS FOLLOWS:

GREASE INTERCEPTOR REQUIREMENTS

CITY OF NEWTON Septage and Grease Trap Waste Disposal Program TABLE OF CONTENTS

PRESSURE DISTRIBUTION COMPONENT MANUAL FOR PRIVATE ONSITE WASTEWATER TREATMENT SYSTEMS (VERSION 2.0) January 30, 2001

JEFFERSON COUNTY ENVIRONMENTAL SERVICES DEPARTMENT GREASE CONTROL PROGRAM FOOD SERVICE FACILITY GREASE CONTROL PROGRAM PERMIT APPLICATION

Grease Inspection Program

Excerpt from Chapter 3 of the City Code that address Fats, Oils and Grease (FOG) control program that was adopted by the City Council on May 9, 2016.

National Association of Wastewater Transporters (NAWT) Onsite Treatment Tank Pumping & Cleaning Code of Practice

Washtenaw County DESIGN PROCEDURES AND ENGINEERING STANDARDS FOR PRESSURE DISTRIBUTION NETWORKS

1BGrease Traps and. Frequently Asked Questions About Grease:

Septic Tanks. Effluent Screen Cleaning. Effluent Screens. Surveying Abbreviations. Installation Keys. Septic Tanks, Holding Tanks & Pump Tanks

Main Toll Free Range Road 73, Parkland County, Alberta T0E 0S0

Hampton Roads Planning District Commission

ARKANSAS DEPARTMENT OF ENVIRONMENTAL QUALITY STATE INDUSTRIAL PERMIT INSPECTION FORM. Permit No.: 4369-WR-1 Inspection Date: September 7,2006

CITY OF DALLAS WATER DEPARTMENT LIQUID WASTE PROGRAM APPLICATION FOR LIQUID WASTE TRANSPORTATION PERMIT

Operation and Maintenance

Sequencing Batch Reactor. Maintenance Manual. Only modules bearing the NSF logo and designated PS1-XX are certified to NSF/ANSI Standards 40 and 245

GREASE INTERCEPTOR REQUIREMENTS Lakeway Municipal Utility District

City of Greenfield WWTP

CHAPTER 20.1 WASTEWATER HAULING. Section Definitions. For the purposes of this article, the following definitions shall apply:

Florida Community Services Corporation of Walton County d/b/a Regional Utilities (Regional) FOG Control Policy

One City Plaza, Suite B P.O. BOX 1287 Cabot, Arkansas Phone Revised: April 2, 2019

AMENDED CULVERT POLICY WITH MAIL BOX POLICY

SUBJECT: THIS IS THE ANNUAL GREASE DAMAGE PREVENTION PERMIT.

CROW WING COUNTY HIGHWAY DEPARTMENT APPLICATION FOR PERMIT TO CONSTRUCT DRIVEWAY ACCESS TO ROADS UNDER COUNTY JURISDICTION CONSTRUCTION INFORMATION

Application for Interconnection and Net Metering Revision: 1 Revised: November 7, 2017

Sequencing Batch Reactor. Reference Manual. Only modules bearing the NSF logo and designated PS1-XX are certified to NSF/ANSI Standards 40 and 245

City of Derby Water Pollution Control Authority Fats, Oils, and Grease Pretreatment Regulations Adopted March 15, 2017

Public Utilities HILLSBOROUGH COUNTY GREASE HAULER PERMIT APPLICATION

ST. TAMMANY PARISH COUNCIL ORDINANCE

Fats, Oil, and Grease (FOG) Best Management Practices (BMP) For Food Service Facilities Information, Pollution Prevention, and Compliance Information

Thank you for your application for product renewal dated February 28, 2017, for the Fuji Clean USA CEN Model Series Treatment Systems.

SLUG CONTROL PLAN. Section A - Spills from Water-Using Process Areas

REGULATIONS CONCERNING TRAILER PARKS COBB PUBLIC HEALTH

DRIVEWAY STANDARDS EXHIBIT A. The following definition shall replace the definition of driveway in Section 62:

ABCD BFDC BEDA AB CDEFCC

Sewerage Services.

BECKLEY. General: Page 1

RESOLUTION TOWNSHIP OF SUMPTER SEWER, WATER, RUBBISH RATES, CAPITAL BENEFIT CHARGES

Recirculating Media Filters OWNER'S MANUAL

SaniTEE Wastewater Screens Installation & Service Manual FOR USE WITH SNT416, SNT418, SNT818, SNT 838, SNT1618, and SNT1638

Installation Instructions

REQUEST FOR PROPOSALS FIRE HYDRANT MAINTENANCE SERVICES

Bhagawati International Limited

RESIDENTIAL NEW CONSTRUCTION PACKET CITY OF VERO BEACH UTILITIES. Important Notice to Builders/Contractors/Developers From Electrical Engineering

Flood Dosed System Worksheet

Regulation of Commercial Waste Originators, Pumpers, Transporters, Processors, and Disposal Facilities

MASTER FEE SCHEDULE. $50 initial minimum charge plus $20 per hour if minimum is exceeded COMMERCIAL RATES. Once per week collection

PUMP TYPES. Pump Sizing. Dose to Gravity. Pumping to Gravity Distribution. Systems that need a Lift. Distribution Box and Tiered Trenches.

RIDESMART VAN START PROGRAM & EMERGENCY ASSISTANCE PROGRAM FOR EXISTING VANPOOLS ELIGIBILITY AND APPLICATION FORM

Sewerage Service Regulation, Fees and Charges Bylaw

Bidwell Porter WWTP. General Information County: Gallia Counties Served: Gallia. Type of System: Public: X Private: Year Established: 1999

STANDARD DRAWING INDEX

BNR Series Wastewater Treatment Systems Washington State Installation & Owners Manual

One City Plaza, Suite B P.O. BOX 1287 Cabot, Arkansas Phone Revised: May 06, 2016

CHAPTER 7 HEALTH & SANITATION ARTICLE 3 - REFUSE - GENERAL PROVISIONS. Section Equipment for hauling refuse and yard waste - secured loads.

3. Application Fees, Certificate Of Insurance & Performance Bond

DEPARTMENT OF THE ARMY HEADQUARTERS, UNITED STATES ARMY AVIATION CENTER AND FORT RUCKER FORT RUCKER, ALABAMA

MASTER FEE SCHEDULE. SECTION 1: Refuse/Garbage and Recycling Fees (C of O Sec )

Pressure Distribution. Western Canada Onsite Wastewater Management Association

EXHIBIT A EAST VALLEY WATER DISTRICT SCHEDULE OF WATER AND WASTEWATER RATES AND CHARGES

When is Septage Really Septage? GLAD TO SEE YOU MADE THE MOVE!

Keycodes Inspection Agency PO Box 391 Bethlehem, Pennsylvania

Table of Contents. Introduction. Off-loading/ Unpacking Instructions. Installation Instructions. OPS (Operations/Control Center) Installation

NOTE: ALL PRINTED EQUIPMENT OPERATING PROCEDURES ARE CONSIDERED UNCONTROLLED UNLESS STAMPED IN RED: CONTROLLED DOCUMENT.

Western Virginia Water Authority Schedule of Monthly Water Rates Botetourt County Customers

BNR Series Wastewater Treatment Systems Installation & Owners Manual

Western Virginia Water Authority Schedule of Monthly Water Rates Roanoke City and Roanoke County Customers

DRIVEWAY/APPROACH PERMIT APPLICATION Applicant Type: Architect/Engineer Contractor Owner

CHAPTER 50: GARBAGE GENERAL PROVISIONS

BUSINESS LICENCE APPLICATION FOOD TRUCK

RESOLUTION NO. Date Passed: November 14, 2016 ESTABLISHING CITY OF ROCHELLE WATER RATES, EFFECTIVE JULY 1, 2017

AMERICAN RECIRCULATING SAND FILTER SYSTEMS

FORT RUCKER Environmental Management System

Western Virginia Water Authority Schedule of Monthly Water Rates Franklin County Customers

Instructions for Completing Oncor s Interconnection Application For Solar PV Projects

Western Virginia Water Authority Schedule of Monthly Water Rates Franklin County Customers

Fats, Rags, Oils, and Grease Program. Bedford Regional Water Authority

AT Series Owners Instruction Manual Installation Manual, Operating Manual, Design Drawings and Specifications, Service Policy, Limited Warranty

Permitting and Tracking Waste Haulers

Pressure Distribution Design

(a) Administrator means Clearwater's Public Works Administrator or his or her designee.

Mobile Food Unit / Pushcart Application

PORTER TOWNSHIP CASS COUNTY, MICHIGAN PUBLIC WORKS SECTION PART 60 SEPTAGE RECEIVING ORDINANCE ORDINANCE #

JAMES ISLAND PUBLIC SERVICE DISTRICT WASTEWATER COLLECTION SYSTEM FATS, OILS & GREASE PROGRAM

CITY OF ESCONDIDO Planning Division 201 North Broadway Escondido, CA (760) Fax: (760)

Appendix A Technical Specifications Class I, II, III, IV Sewage Pumping Lift Station Wet Well Cleaning and Hauling

Fats, Oils & Grease Ordinance and Program. Presented by Lance McAvoy Deputy Director of Operations

BUILDING PERMIT FEES

City Hall 539 Phoenix Street South Haven, Michigan Telephone (269) Fax (269)

Kentucky On-Site Septic Tank Servicing Regulations

The attached pre-qualification application should be submitted with your bid, in a separate sealed envelope.

Table of Contents. Item Page #

Orenco Automatic Distributing Valve Assemblies

Eligible Renewable Generation (ERG) Application INSTRUCTIONS

WEST BRANDYWINE TOWNSHIP 198 Lafayette Road West Brandywine, PA Fax FEE: $75.00 (Up to 200 S.F.)

Transcription:

ONSITE WASTEWATER TREATMENT SYSTEM Property Transfer Certification Instructions and Inspection Report These instructions are for homeowners and inspectors completing the onsite wastewater treatment system (OWTS) inspection report for a property transfer certificate. The first page of the report must be completed and signed by the homeowner or the person acting as the homeowner s agent. IMPORTANT: Not all systems require an inspection. Visit www.septicsmart.org or call Boulder County Public Health (BCPH) at 303-441-1564 to determine if an inspection is required for the OWTS. The process for issuing a property transfer certificate takes approximately 10 business days from the time the report is submitted to BCPH; the report should be submitted to BCPH at least 2 weeks prior to the closing of the sale. OWNER INFORMATION SECTION The box at the top of the first page of the report MUST be filled out completely. The inspection must be less than 365 days old. SECTION I. GENERAL INFORMATION This section MUST be completed and SIGNED by the homeowner or the homeowner s agent 1. Determine the age of the OWTS through existing permit(s). List the years for each component including septic tank(s), absorption bed(s) and other (pump tanks, ATU, etc.). 2. Mark Yes or No if the property served by the OWTS has a water softener, garbage disposal, or grease trap. 3. Mark Yes or No if the property is residential, commercial, has a water-flow meter, or is a home business (include type). 4. This is a PASS/FAIL criterion. List all structures on the property that have bedrooms and/or plumbing including studios, garages, barns, offices, or other outbuildings with plumbing. List the current number of bedrooms in the main home and other structures that have bedrooms, the number of bedrooms listed on the OWTS permit, and the number of bedrooms listed in the Boulder County Assessor s records. Also include if the home is currently unoccupied; if so, for how long. OWTS records can be found at www.septicsmart.org Assessor s records can be found at www.bouldercounty.org/assessor Note: If the current number of bedrooms in the home or number of bedrooms listed in the assessor s records is GREATER than the number of bedrooms noted on the OWTS permit, it will result in a FAIL, and BCPH will not accept the inspection report until the discrepancy is resolved. Call BCPH if assistance is needed. 5. Note if a sewage backup has ever occurred inside the home. 6. List any known repairs made to the OWTS, even if they were done without a permit. 7. Note if a service contract is in place for system components, such as an aerobic tank, chlorinator, or effluent filter; include the name of the servicing company and provide a copy of the service contract with the inspection report. 8. List the date of the last septic tank pumping, previous to the current inspection, and the frequency with which the septic tank is pumped (e.g. once per year, every two years, etc.). Note the name of the pumping company and attach available receipts (required per State Regulation 43). 9. Note if the water to the property is supplied by a well. 10. Note if a water sample test was taken for potability and if the water sample passed or failed. Property Transfer Renewals will no longer be accepted. Expired Property Transfer Certificates cannot be accepted. If the original inspection report is less than 365 days old it may be used to apply for a Property Transfer Certificate. The fee is $50.

SECTION II. SYSTEM TYPE Sections II-IV must be completed and signed by the inspector. 1. List the type (e.g. concrete, plastic), manufacturer, and capacity of the septic tank or write in unknown. 2. List the capacity of the lift station (i.e. pump tank) if applicable, or write N/A. 3. List the type of secondary tank utilized if applicable, or write N/A. 4. List the capacity of the secondary lift station if applicable, or write N/A. 5. Mark the type of soil treatment unit utilized (i.e. absorption bed, trenches, chambers, drip irrigation, ET, etc.). List the soil treatment area in square feet. 6. If there is a vault ONLY, list the type, manufacturer, and capacity. Check if the warning device is a Pass (i.e. is present and functioning) or Fail. Note the location of the warning device. Check if pumping receipts Pass (i.e. are available and will show that the tank is pumped frequently, permitting all wastewater to go into the vault and pumped out before filling to capacity) or Fail. 7. List any additional components employed with the OWTS. 8. Note if any greywater discharge is observed and where it is noted. If surface greywater discharge is observed, mark Fail. SECTION III. EVALUATION PROCEDURES The NAWT (National Association of Wastewater Technicians) inspector must walk through the home to verify the current number of bedrooms. Inspectors must use the following definition for a legal bedroom: A room with a closet, a window, and private access such that access to other rooms does not have to be gained by going through the bedroom. Basement bedroom windows must meet this egress code: a minimum clear width of 20", a minimum clear height of 24", with a total net clear opening of 5 sq. ft. for grade-level windows and 5.7 sq. ft. for all others. Sill height must be not more than 44" above the finished floor. The number of bedrooms currently in the house must not exceed the number of bedrooms listed on the Boulder County Public Health OWTS permit for the property. Go to www.septicsmart.org, click on Check Septic Records, and confirm the number of bedrooms approved by the OWTS permit. 1. Note the number of current bedrooms counted (according to the legal definition above) and if that number doesn t exceed number on OWTS (i.e. Pass) or does exceed the number on the OWTS permit (i.e. Fail). Note any structures, other than the main house, on the property that have plumbing (YES/NO). If YES, all structures must be verified as connected to the OWTS and approved to be connected from BCPH permit records. If they are not, the report is a failing inspection and must be noted as Unacceptable with comments on inspection results of OWTS-Item #16. 2. Note if the septic tank was located, accessed, and opened. 3. Note if the tank cover is secured. 4. Note if the tank seal was checked for integrity. 5. Note if any indications of previous failure, such as past repairs to the tank, were made. 6. Note if the tank lid integrity was inspected and if the sludge and scum layer in the tank was measured. 7. If applicable, note if the effluent filter was inspected. 8. Note if there a diverter valve utilized for a two-bed system (YES/NO). 9. If a diverter valve is installed note if it is operational (PASS/FAIL). 10. Note if an operation test was run, how many gallons of water were added to the tank, and if water flowed back into the tank. A maximum of 100 gallons of water should be added per bed during an operation test. If there is a two-bed or multiple-bed system with a diverter valve, an operation test must be conducted on all absorption beds and noted on the inspection report. 11. Note if the primary septic tank was pumped and how many gallons were pumped out. The septic tank must be pumped in order to conduct a complete inspection of the tank interior. If the septic tank is not pumped, the inspection report will be considered a failed inspection. 12. Note if the condition of the septic tank and the inlet and outlet tees were inspected, and comment on the condition.

13. Note if a dosing, pump tank or advanced treatment unit (ATU) is utilized and whether the condition was checked. a. Check the condition of the tank and note comments b. Check if the pump (dosing or pump tank only) is elevated off of the tank bottom. c. Check if the pump (dosing or pump tank only) is working. If not, mark Fail. d. Note if a check valve or purge hole is present. e. Note if a high water alarm float is present. f. Check the alarm float. If alarm float doesn t work, mark Fail. g. Mark the type of alarm utilized. h. Inspect electrical components to ensure they are satisfactory. i. Note if the pump/atu tank was cleaned out. If not mark Fail j. For ATU, note if the motor is working or not, if not working, mark Fail k. For ATU, note if there is a current operation & maintenance agreement/contract in place. 14. Check if the treatment area was probed and if excessive moisture, odor, and/or effluent were present. a. Check to see if the area of the system is properly graded and not subject to serious erosion, such as channeling or gullying. No portion of the system may be uncovered or exposed. b. Mark Yes if the system is located in a corral; under a driveway, parking lot or other structure; or otherwise subject to compaction. If not mark No. c. Note if there is any indication of previous failure, such as excessive growth in one area, organic deposit, erosion, etc. d. Note if any visible seepage of effluent is present on absorption field. If so, mark Fail. e. Mark No if the area of the system is well-vegetated with grasses, weeds, and wild flowers, with only an occasional small shrub. If the area is heavily vegetated with shrubs and/or trees to the extent that it will allow root infiltration into the system, mark Yes. f. Note if the system area contains heavy saturation in the gravel or media area by probing or observing monitor ports. g. Note if effluent is being distributed evenly in the system area. h. Note Yes if snow cover is present to the extent that it would limit the inspector s ability to properly evaluate the system. i. Note if irrigation is present on the field such as water sprinklers. 15. Note the distance from any well to the closest edge of the system area, measured in linear feet. 16. Note inspection results as Acceptable or Unacceptable. Note if repairs to the OWTS are required, and explain the repairs required. All instances of failure and malfunction required to be documented with photographs. Attach repair photographs to inspection report. Note if an entire system replacement is required or if further exploratory work is required. SECTION IV. SKETCH OF THE SYSTEM. Make an accurate sketch of the entire system that shows a north arrow and the location of the dwelling or structure with two triangulated distance measurements to the septic tank lid(s) or GPS coordinates. Include sewer location to structure, septic tank(s), lift station, and soil treatment area. Include all pertinent setback locations, such as lakes, rivers, irrigation ditches, and water wells. Note: BCPH does NOT accept final drawings from existing permits.

Boulder County Public Health ONSITE WASTEWATER TREATMENT SYSTEM (OWTS) Property Transfer Inspection Report Name of Owner: Date of Inspection: Inspection Ordered By: Name of Inspector: Site Address: Inspector s Certification No: Owner s Phone: Inspector s Address: Property Legal Description: Inspector s Phone: Send Inspection Report To: Inspector s E-mail: Mailing or Email Address: Size of Property (i.e. # of acres): Type of Existing Building or Structure (if commercial, list all uses or tenants): I. GENERAL INFORMATION (TO BE COMPLETED AND SIGNED BY OWNER) 1. Age of OWTS: Tank(s) years Absorption Bed(s) years Other years 2. Water Softener Yes No Garbage Disposal Yes No Grease Trap Yes No 3. Residential Yes No Commercial Yes No Flow Meter Yes No In-Home Business Yes No Type: 4. BEDROOMS: Number counted in structures Number Listed on OWTS Permit PASS FAIL Number Listed in Assessor Record Is House Currently Unoccupied? Yes No How long? 5. Has a sewage backup ever occurred? Yes No 6. List any known repairs to system 7. Is there a service contract for system components? Yes No Company: 8. Date septic tank last pumped prior to this inspection: Frequency: Company: (Attach pumping receipt) 9. Water supply supplied by a well? Yes No 10. Potability test sample of well taken? Yes No Potability test results: PASS FAIL (NOTE: A pass or fail here does not indicate a pass/fail for the inspection) NOTE: Property Transfer Renewals will no longer be accepted. The above information is true to the best of my knowledge. Owner/Legal Agent: Date:

II. SYSTEM TYPE: Components of OWTS (complete as required) 1. Pretreatment (Septic Tank) Unit 1: Type Manufacturer Capacity (gal) 2. Pump Tank 1: Capacity (gal) 3. Pretreatment/Treatment Unit 2: Type Manufacturer Capacity (gal) 4. Pump Tank 2: Capacity (gal) 5. Soil Treatment Unit: Type: Area (Ft 2 ) 6. Vault (see instructions) Type Manufacturer Capacity (gal) Warning Device PASS FAIL Pumping Receipts (vault only) Yes No Location of warning device: 7. Additional Components: 8. Greywater Discharge (if separate from OWTS): None Surface Subsurface Tank III. EVALUATION PROCEDURES 1. Number of bedrooms counted in house: PASS FAIL Are there other structures with plumbing? YES NO (If YES, all structures must be verified as connected to the OWTS and approved to be connected from BCPH permit records. If they are not, the report is a failing inspection and must be noted as Unacceptable with comments on inspection results of OWTS-Item #16) Number of bedrooms doesn t exceed OWTS record: PASS FAIL 2. Locate, access, and open the septic tank cover: PASS FAIL 3. If at grade, is tank cover secure? PASS FAIL 4. Can surface water infiltrate into tank(s)? No/PASS Yes/FAIL 5. Any indicators of previous failure? Yes No 6. Inspect lid; measure sludge and scum level: Yes No 7. Inspect effluent screen (if applicable): 8. Is there a diverter valve installed (multi-bed system)? 9. If there is a diverter valve, is it operational? 10. Run an operation test (all beds if multiple-bed system): Yes Yes Yes/PASS No No No/FAIL a. Gallons added in the operation test : gallons b. Does water backflow into tank? No/PASS Yes/FAIL 11. Pump out primary treatment (septic) tank: Yes No/FAIL a. How many gallons? gallons 12. Inspect the condition of the septic tank: PASS FAIL a. Inspect condition of inlet and outlet baffles Yes No b. Comments (cracks, deterioration, infiltration, or damage): 13. Does the system contain a dosing or pump tank, ejector, or grinder pump or an Advance Treatment Unit (ATU)? Yes No a. If so, was the condition of the tank checked? Yes No Comments: b. Is the pump elevated off the bottom of the tank? Yes No NA c. Does the pump work? Yes/Pass No/Fail NA d. Is there a check valve or purge hole present? Yes No NA e. Is there a high water alarm? Yes No NA f. Does the alarm work? Yes/Pass No/Fail NA

g. Type of alarm: Audio Visual Both h. Do electrical connections appear satisfactory? Yes No i. Was the pump/atu tank cleaned? Yes/Pass No/Fail j. If an ATU, is the motor working? Yes/Pass No/Fail k. If an ATU, is there a current operation & maintenance agreement in place? Yes No 14. Was the soil treatment area probed to determine its location and to check for excessive moisture, odor, and/or effluent? Yes No a. Any area subject to serious erosion? Yes No b. Any area subject to compaction? Yes No c. Any indication of previous failure? Yes No d. Seepage visible on the surface of the field? PASS FAIL e. Is improper vegetation present? Yes No f. Heavy saturation in the distribution media? Yes No g. Even distribution of effluent in the field? Yes No h. Snow cover over the absorption area? Yes No i. Irrigation present on absorption area? Yes No 15. Distance between water well and soil treatment area: Feet 16. Inspection results of OWTS: Acceptable (no repairs required) Unacceptable (repairs required) Repairs required Photo Documentation required for of all instances of malfunctions/failures and of any repairs made Explain/define repairs needed or repairs made.: Complete system replacement required. Explain: Further exploratory work is required. Explain: IV. SKETCH OF SYSTEM Make an accurate sketch of the entire system that shows a north arrow, the location of the dwelling or structure(s) with two triangulated distance measurements to the septic tank lid(s) or GPS coordinates. Include sewer location to structure, septic tank(s), lift station, and soil treatment area. Include all pertinent setback locations, such as lakes, rivers, irrigation ditches, and water wells. Note: BCPH will NOT ACCEPT final drawings from existing OWTS permits. By signing this form, I hereby verify that I am a NAWT or NSF-certified inspector who personally conducted the inspection of this property. Certified Inspector Signature: Date: