INSTALLATION INSTRUCTIONS

Similar documents
Emco Logo on Scuff INSTALLATION INSTRUCTIONS

Stay-put scuff guard helps to protect the dispensers from scratches and the breakaway during a drive-off event

New Amendment to Executive Orders VR-203-N & VR-204-N

INSTALLATION INSTRUCTIONS. Double Wall, Drain Valve, BSPT. Torque Wrench w/ 100 to 150 ft-lbs. Setting

Executive Orders VR-203-F and VR-204-F VST Phase II EVR System. Exhibit 5 Liquid Removal Test Procedure

Executive Order VR-205-B VST Phase II EVR System with Hirt Thermal Oxidizer. Exhibit 2 System Specifications

ENVIRO-LOC Low Permeation Premium Conventional Curb Pump Hose assemblies are available for purchase from VST Model V58EC.

State of California AIR RESOURCES BOARD EXECUTIVE ORDER VR-204-U. Relating to Certification of Vapor Recovery Systems

Exhibit 5. Vapor to Liquid Volume Ratio (Executive Orders VR-201-F and VR-202-F) (Healy Model 900 EVR Nozzle)

State of California AIR RESOURCES BOARD EXECUTIVE ORDER VR-209-A

4. No person shall install a coaxial Phase I vapor recovery system unless the system was certified by CARB after January 1, 1994.

RULE 448 GASOLINE TRANSFER INTO STATIONARY STORAGE CONTAINERS Adopted (Amended , , , , , ) INDEX

RULE 449 TRANSFER OF GASOLINE INTO VEHICLE FUEL TANKS

State of California AIR RESOURCES BOARD EXECUTIVE ORDER VR-203-F

Glenn K. Walker. Product Bulletin. VST Balance Nozzle Clip Removal and CARB Advisory

Healy VP Troubleshooting Guide

EVR Hose Configuration

The purpose of this rule is to limit emissions of gasoline vapors from the transfer of gasoline into motor vehicle fuel tanks.

Important Information: Aboveground Gasoline Storage Tanks Upcoming Standing Loss Control & Phase I/II EVR Requirements

The purpose of this rule is to limit emissions of gasoline vapors from the transfer of gasoline into motor vehicle fuel tanks.

Air Quality Requirements for Gasoline Dispensing

The VST Enviro-Loc Vapor Recovery System

Executive Order VR-205-B VST Phase II EVR System with Hirt Thermal Oxidizer

TRANSFER OF GASOLINE FROM STATIONARY UNDERGROUND STORAGE TANKS INTO VEHICLE FUEL TANKS (Effect. 03/01/06: Rev. 03/26/08)

REGULATION II PROHIBITIONS. 1.1 Purpose To limit the emission of gasoline vapor into the atmosphere during the filling of motor vehicle fuel tanks.

State of California AIR RESOURCES BOARD EXECUTIVE ORDER VR-302-B

Vapor Recovery Assist System

VST EVR Total Balance System Solution

Enhanced Vapor Recovery and In-Station Diagnostics. Presented by: Matthew Schuessler, N Cal Territory Mgr 1

M-1115S Series Fuel Pump

IMPORTANT INFORMATION

700 Series Hanging Hardware

Operation, Installation, Maintenance and Repair Guide. HighFlo (HF) Control Handle. SERVICE BULLETIN SB 3097 Rev. A 6/14

Franklin Fueling Systems

Imperial County Air Pollution Control District Rule 415

M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual

STP-MLD Installation and Owner s Manual

APPENDIX B. DYNAMIC PRESSURE PERFORMANCE TEST (taken from BAAQMD test procedure ST-27)

AVRN Vacuum Assist Nozzle

RELIANCE G6200 MECHANICAL FLEET DISPENSER

Update on Enhanced Vapor Recovery (EVR) and In-Station Diagnostics (ISD) at Gasoline Dispensing Facilities

State of California AIR RESOURCES BOARD EXECUTIVE ORDER NVR-1-C. Relating to Certification of Non-Vapor Recovery Hoses

Defender Series. Overfill Prevention Valve. Automatic Shutoff for USTs. Installation, Operation and Maintenance Series

STP-MLD+ Installation and Owner s Manual. Manual # Revision Date Changes from previous revision

San Joaquin Valley Air Pollution Control District Vapor Recovery Requirements for Permitted Agricultural Gasoline Storage and Dispensing Operations

FUEL DISPENSING SYSTEMS SE-47. Component Details. 120V AC - 18 GPM Metered Tank-top Pump, Remote Dispensing System

A1100 GUARDIAN OVERFILL PREVENTION SYSTEM

FUEL DISPENSING SYSTEMS SE-37. Component Details. 120V AC - 20 GPM Metered Tank-top Dispensing System

INSTALLATION INSTRUCTIONS FOR THE TRUCK MOUNTED VIPER ADDITIVE INJECTION SYSTEM GTP-8776C

Executive Order G F

VST continues our engineered solutions market approach with two new product selections.

Polypropylene Piston Drum Pumps

General information about underground storage tank (UST) fueling systems in every day language.

M-3025CB-AV Fuel Pump

Conventional Fueling 11A 11B. 1A Automatic Nozzle

Firehawk Second Stage Regulator Fire Service

MR 5-30 or MR 5-30N Series Fuel Meter Owner s Manual

Cylinder and Valve: AirHawk II Air Mask

Installation, Operation & Maintenance Manual for Flo-Max II Coupler Model FM126

STP-MLD. Installation and Owner s Manual

State of New Jersey. Department of Environmental Protection Air Quality Permitting

MECHANICAL FUEL METER. FM-100 and FM-200 Series Owner s Manual

Vapor Tight Overfill Prevention Valves

Installation, Operation & Maintenance Manual for Flo-Max II Coupler Model FM126

Installation & Operation Manual. IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE.

AIR CLEANER GENERAL REMOVAL. 1CAUTION Do not run engine without filter element in place. Debris could be drawn into the engine causing damage.

Second Stage Regulator - 1/4 Turn

Panther HP Oil Pump Series

and 1/4 TURN SECOND STAGE REGULATOR TAL 502 (L) Rev. 0 MSA 2005 Prnt. Spec (I) Mat Doc

Stainless Steel Rotary Drum Pump

SID SERVICE INFORMATION DIRECTIVE Compliance Will Enhance Safety, Maintenance or Economy of Operation TELEDYNE CONTINENTAL AIRCRAFT ENGINE

INSTALLATION & MAINTENANCE MANUAL

MODEL 11A REGULATOR

PT Optimum Series Illustrated Parts Manual

Firehawk Responder Second Stage Regulator

Installation, Operation & Maintenance Manual for Flo-Max Couplers Model FM

Overfill Prevention Valve

E. Augusta, Spokane, WA (509) E. Augusta, Spokane, WA (509)

SERVOMEX 335A2014 PURGE ASSY Operator Manual

MR 5-30 Aviation Fuel Meter Owner s Manual

Cast Iron Rotary Drum Pump

Operating Instructions & Parts Manual. Supa-Lite Lever Grease Gun. Model 48UJ77

FUEL DISPENSING SYSTEMS SE-27. Component Details. 12V DC - 15 GPM Metered Tank-top Dispensing System

Binks FRX20 FLUID SECTION

Oil Control Handle with Mechanical Meter. Introduction. General Information. Important Information 3575-A 3575-B 3575-C 3575-D

M-1115S Series Fuel Pump

GILBARCO ENCORE 300 & 500 SERIES DISPENSER RETROFIT with VDC control valves for HEALY SYSTEMS, INC. MODEL VP1000 VAPOR RECOVERY ASSIST SYSTEM OUTLINE

Thank you for purchasing a Nelson RainTrain2.

Items # and #

ENTIRE FUELING PROCESS IN & OUT IN 5 MINUTES*!

Emergency Shear Valves

Installation, Operation & Maintenance Manual for Flo-Max Couplers Model FM

CM-3120 (115-volt, NPT, Gallon or Litre) CM-3220 (230-volt, NPT, Gallon) CM-3260 (230-volt, BSPT, Litre) Heavy Duty Cabinet Model Fuel Transfer System

TRANSFER OF ORGANIC COMPOUNDS INTO MOBILE TRANSPORT TANKS (Effect: 5/6/77: Rev. Effect. 7/26/00)

MR 5-30 or MR 5-30N Series Fuel Meter Owner s Manual

Operating Instructions & Parts Manual. Oil Control Gun. Models 48UJ82, 48UJ83, 48UJ84, 48UJ85 and 48UJ86

Product Owner s Manual. 8 GPM / 30 LPM, 12-volt Fuel Transfer Pump. Model G8P

Instructions for Installation, Operation Care and Maintenance

Model PRO 3500sc Electrostatic Air Spray Gun 65 kv, MANUAL GUN

PeroxiDraw Dispenser

Transcription:

A4005EVR Balance Vapor Recovery Nozzle RA4005EVR = Rebuilt XXX = Scuff Guard Color Permanent ID Information: Emco Logo on Boot Connector Emco Logo on Scuff Model No. on Spout Emco Wheaton Security Rivet Emco Logo on Lever Guard UL Logo Serial Number Plate INSTALLATION INSTRUCTIONS Service Tools Required: 2 Crows Foot Torque Wrench w/ 50 ft-lbs Setting 1 7/8 Crows Foot Pipe Wrench w/ Flat Jaws Gasoline Approved Container Petroleum Jelly or Other Suitable Lubricant CAUTION: 1. Always barricade work area to keep pedestrians and vehicles from accessing the dispenser. 2. Always use a gasoline approved container or test can when performing any type of preventive maintenance. 3. Before attempting to install, remove or service the A4005EVR nozzle, turn off and tag out power to the corresponding dispenser. 4. Before attempting to install, remove or service the A4005EVR nozzle, close the emergency impact valves located inside the base of the dispenser. Relieve the line pressure and standing fuel through the nozzle spout into a gasoline approved container by compressing the bellows and squeezing the lever. IMPORTANT: Failure to perform cautions 3 and 4 may result in a hazardous gasoline spill, damage to equipment, personal injury and/or death. 1

Pre-Inspection: Band Clamps Scuff Guard Boot Face Spout Automatic Shut-off Bellows Hold-open Latch Security Rivet Fuel Path O-rings Lever Guard Lever Serial Number Plate 1. Carefully unpack and remove the A4005EVR nozzle from the shipping container. Evaluate the following components for damage: scuff guard, lever guard, lever, hold open latch, serial number plate, security rivet, bellows, band clamps, boot face and spout. 2. Verify the automatic shutoff located at the end of the spout. The vent hole must be free and clear of all debris. 3. Verify the fuel path o-rings located at the hose end of the A4005EVR nozzle. Both o-rings must be properly secured inside the factory machined grooves. Pre-Functional Test: 4. Functional test the insertion interlock of the A4005EVR nozzle by compressing the bellows and then squeezing the lever. The A4005EVR nozzle will not function unless the insertion interlock is properly engaged. Pre-Installation: Fuel Path O-rings 5. Lightly lubricate both fuel path o-rings using petroleum jelly or other suitable lubricant. 2

Swivel Nut Vapor Path O-ring Hose Connector Vapor Path O-ring 6. Before attempting to install the A4005EVR nozzle onto the A4110EVR hose swivel or curb hose, verify the vapor path o-ring is properly secured onto the swivel nut or hose connector. The vapor path o-ring must be good working condition. Lightly lubricate the o-ring using petroleum jelly or other suitable lubricant. IMPORTANT: Do not use pipe thread sealant compound or Teflon tape when installing the A4005EVR nozzle. Failure to comply will void warranty. IMPORTANT: The A4110EVR hose swivel is only approved for use with the EMCO Wheaton Balance Phase II EVR System California Air Resources Board Executive Orders VR-207 and VR-208. Installation: IMPORTANT: If this is a new facility installation, the fueling point must be flushed into a gasoline approved container before installing the A4005EVR nozzle. Failure to perform this procedure could result in foreign material becoming lodged inside the nozzle's fuel path causing it not to shut off or a reduction in fuel flow. 7. Attach the A4005EVR nozzle onto the swivel nut or hose connector. Tighten by hand to avoid cross threading. Take caution to avoid pinching the vapor path o-ring. Apply torque here Apply torque here 8. Using a 2 crows foot and torque wrench, tighten the swivel nut to 50 ft-lbs of torque. Using a 1 7/8 crows foot and torque wrench, tighten the hose connector to 50 ft-lbs of torque. 3

Post Functional Tests: 9. Carefully purge the trapped air from the fueling point. Begin dispensing by compressing the bellows and then squeezing the lever. Dispense one gallon of fuel into a gasoline approved container. 10. Functional test the automatic shutoff of the A4005EVR nozzle. Begin dispensing by compressing the bellows and then squeezing the lever. Place the hold-open latch in high clip position to secure the lever. Dispense one gallon of fuel into a gasoline approved container. At the same time, lower the spout tip into the standing fuel until the vent hole is completely submersed. The main valve of the A4005EVR nozzle will automatically close causing fuel flow to stop. IMPORTANT: Perform step 10 a minimum of three times to assure the insertion interlock, hold open latch and the automatic shutoff of the A4005EVR nozzle are operating properly. According to UL requirement 842, the fuel flow rate must be greater than 3 gallons per minute for the automatic shutoff to operate properly. A common cause of low flow rates are dirty or clogged dispenser filters. Post Inspection: 11. Before placing the A4005EVR nozzle onto the dispenser cradle, inspect all hanging hardware connections for potential fuel leaks. Make proper adjustments if necessary. PREVENTIVE MAINTENANCE 1. Weekly inspect the A4005EVR nozzle, evaluate the following components for damage: scuff guard, lever guard, lever, hold open latch, serial number plate, security rivet, bellows, band clamps, boot face and spout. Damage components must be replaced with factory authorized service kits. 4 Part Number 492775EVR 492776EVR 492834EVR 494150EVR 494748EVR 494750EVR A0557EVR-XXX Description Bellows & Boot Face Kit Boot Face Kit Spout Kit Latch Kit Fuel Path O-ring Kit Bellows Band Clamps Kit Scuff Guard Kit

IMPORTANT: Do not remove the serial number plate and security rivet from the A4005EVR nozzle. Failure to comply will void warranty. 2. Weekly inspect the automatic shutoff located at the end of the spout. The vent hole must be free and clear of all debris. 3. Weekly inspect all hanging hardware connections for potential fuel leaks. IMPORTANT: Should a drive-off or incidence of customer abuse occur, follow the initial inspection and function instructions found in the installation section. PERFORMANCE STANDARDS & SPECIFICATIONS This component was factory tested to, and met the following specifications: 1. Meets ARB Material Compatibility with Fuel Blends as per Section 3.8 of CP-201. 2. Meets ARB Capable of Refueling Any Vehicle Standards as per Section 4.7.1 of CP-201. 3. Meets ARB Spout Dimension Standards as per Section 4.7.3 of CP-201. 4. Meets ARB Nozzle and Dispenser Compatibility Standards as per Section 4.9 of CP-201. 5. Meets ARB Balance Nozzle Criteria Standards as per Section 5.1 of CP-201. 6. TP-201.2B Complies with the maximum allowable leak rate of 0.07 CFH @ 2.00 inches of water column pressure. 7. TP-201.2C Complies with the maximum allowable spillage factor of 0.24 pounds/ 1,000 gallons. 8. TP-201.2D Complies with the maximum allowable average of 3 post fuel drips. 9. TP-201.2E Complies with the maximum allowable average of 100mL liquid retention and 1mL liquid spit-back. 10. TP-201.2J Complies with the maximum allowable component pressure drop of 0.08 inches of water column @ 60 CFH. IMPORTANT: Leave these installation instructions with the station owner and/or operator. 5

IMPORTANT: Leave these installation instructions, product warranty registration card and the warranty tag with the station owner and/or operator. 6 Emco Wheaton Retail Corp. 2300 Industrial Park Dr. Wilson, NC 27893 252-243-0150 252-243-4759 (fax) p/n 569044 Rev. G, 03/13