Operating instructions Mechatronic flow sensor SBY /00 03/2011

Similar documents
Operating instructions Flow monitors SI / / 2010

Operating instructions Flow monitors SI6600 SI6700 SI /02 01/2011

Installation Instructions Electronic pressure sensor. PX3111 PX322x PX323x PX3244 PX3422 PX911x PX913x

Operating instructions Flow monitors SI5002 SI5003 SI / / 2012

Operating instructions Flow monitors SI6000 SI6100 SI /00 06/2011

Operating instructions Flow monitors SI5000 SI / / 2007

Operating instructions Binary level sensor LMT /00 06/2011

Operating instructions Binary level sensor. LI214x /00 04/2016

Operating instructions Flow monitor SI / / 2014

Operating instructions Flow monitor SI / / 2013

Differential Pressure Sensors

Pressure Sensors. for liquid and gaseous media

Pressure sensor for liquid and gaseous media QBE620-P...

Operating instructions Electronic level sensor LK7 / LK /07 04/2006

Differential Pressure Sensors

BODAS Pressure sensor PR3 series 10

Pressure transmitters for heavy duty applications Type MBS 3250

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

Positive displacement batch controller

FUEL FLOW METER AIC / 920 VERITAS

HBLT-Wire LEVEL SENSOR For analogue measurements of NH3 and HFC in refrigeration systems

Pressure Transmitter

Overview of types. Technical data

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends

QB4 PRESSURE CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS

OBE (On-Board Electronics) Type Direct Operated Linear Servo Valves (Size: 01 & 03) LSVG-01-EH-*-**-**-10, LSVG-03EH-*-**-**-10/1006

Pressure transmitters for heavy duty applications MBS 3200 and 3250

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

8000 Series Liquid Flow Meter

ELECTRONIC CONTROLLER

Schmidt Mess- und Regeltechnik

Installation and Operating Instructions DDM-DS11 DDM-DS11-MS1 DDM-DS11-MS2

8000 Series Liquid Flow Meters

OPERATION & MAINTENANCE INSTRUCTIONS

FUEL FLOW METER AIC / 908 VERITAS

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

kvs theor.: Theoretical kvs value for pressure drop calculation Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

Modulating control valves with magnetic actuator PN 16

Types K510 / K520 / K130 / K610 / K620 / K522 (Angle 90 ) Measuring ranges from -60 C to +200 C.

Electric Fuel Pump FPM

VSO - MI thermally compensated proportional valve

Solenoid Pilot Operated Proportional Directional Control Valve

VSO Thermally Compensated Proportional Valve

Paddle-wheel flow controller for On/Off control

Battery Charger JCB- SCH20LI.2

Miniature Proportional Valve Thermally Compensated Proportional Valve. Physical Properties

High temperature pressure transmitters for heavy-duty applications MBS 2200 and MBS 2250

SUBMERSIBLE DIRTY WATER PUMP

PSF50 Paddle flow switch

Catalog. Accessories Separ-Filter. Catalog: Accessories Separ-Filter Page 1 of 13

250W PUDDLE PUMP WITH AUTO SENSOR MODEL NO: PSP105

By Karmjit Sidhu, VP, Business Development American Sensor Technologies

VP23 3-way proportional pressure control valve Directly-controlled seat valve with µp-driven pressure control G 1/4... G 3/4

Compact Proportional Solenoid Valve

Differential pressure sensor

Electric Flanged PN16 Cast Iron Ball Valve

Ordering designation: G(Type) - (Stroke) - (Eye bolt) - (Cable length) - (Options) Legend:

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time

D e s c r i p t i o n

Positive displacement flowmeter

XMLR160M2P05 Pressure sensors XMLR 160bar - G 1/4-24VDC - 2xPNP - M12

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050

Car Battery Charger Instructions for Use

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Installation, Operating & Maintenance Instructions. Norbro J-Switch FM 00707

SUBMERSIBLE WATER PUMP

OVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ )

OVAL GEAR FLOWMETER ELECTRONIC MODEL 019 / ¾

SET UP INSTRUCTIONS FIRE ANT GRINDER V1.4

Pressure transmitter for general industrial purposes Type MBS 3000 and MBS 3050

Features. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in)

XMLRM01G1P25 Pressure sensors XMLR -1 bar - G 1/4-24VDC ma - PNP - M12

,

SUBMERSIBLE PUMP HSE RANGE

Miniature Proportional Valve. Non-Thermally Compensated Proportional Valve

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

Process Inline Filter PLF1

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

Proportional Flow-Control Cartridges, Size 5

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

SBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual

JUMO MIDAS S06. OEM-Pressure Transmitter Low Pressure. Applications. Brief description. Customer benefits. Special features

Pneutronics. Miniature Proportional Valves. Catalog PND-MPV-001/US January 2007

Overview of types. Characterised control valves, 3-way, with internal thread For closed cold and warm water systems

DIGITAL RCD(ELCB) TESTER

Transformer Protection

RAY TYPE 1 PRODUCT MANUAL

HBSO1 Oil switch. Instruction manual. For detecting oil in refrigeration systems WE INCREASE UPTIME AND EFFICIENCY IN THE REFRIGERATION INDUSTRY

OPERATION & MAINTENANCE INSTRUCTIONS

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

JUMO MIDAS S05 Pressure transmitter Type

HARMSCO Hurricane Swing Bolt Water Filters Models: HUR 1X170FL, HUR 3X170FL HUR 5X170FL, & HUR 8X170FL

XMLR400M1N26 Pressure sensors XMLR 400bar - 1/4" 18 NPT - 24VDC ma - NPN - M12

THE INSIDE STORY OF THE QPV OR MPV:

Proportional Pressure Reducing Valve PDM08130

SUBMERSIBLE WATER PUMP

XMLR400M1N75 Pressure sensors XMLR 400bar - G 1/4-24VDC V - NPN - M12

Positive displacement flowmeter for continuous flow measurement

SKF Grease injection system

Transcription:

Operating instructions Mechatronic flow sensor SBY357 UK 7060/00 03/011

Contents 1 Safety instructions... Functions and features...3 3 Installation...3 4 Electrical connection...4 5 Switch point setting...4 5.1 Definition of requested value...5 5. Adjustment to existing flow...5 6 Operation...6 7 Maintenance, repair and disposal...6 8 Scale drawing...7 9 Technical data...8 1 Safety instructions Please read the product description prior to set-up of the unit. Ensure that the product is suitable for your application without any restrictions. Improper or non-intended use may lead to malfunctions of the unit or to unwanted effects in your application. That is why installation, electrical connection, set-up, operation and maintenance of the unit must be carried out by qualified personnel authorised by the plant operator. Check the compatibility of the product materials (see technical data) with the media to be monitored in all applications. The device shall be supplied from an isolating transformer having a secondary Listed fuse rated either a) max 5 amps for voltages 0~0 V (0~8.3 Vpeak), or b) 100/Vp for voltages of 0~30 V (8.3~4.4 Vpeak). Flow Operated Switches shall be connected only by using any R/C (CYJV) cord, having suitable ratings.

Functions and features The unit monitors liquid media (water, glycol solutions, oils). It detects the volumetric flow quantity to the principle of differential pressure and switches the output: Output closed (LED = ON), if volumetric flow quantity switch point. Output open (LED = OFF), if volumetric flow quantity < switch point. The switch point is adjustable. 3 Installation Ensure that the system is free of pressure during installation. Ensure that no media can leak at the mounting location during installation. Install the unit according to the marked flow direction into a pipe RP 1½ and tighten firmly. UK IN Rp 1 Rp 1 OUT IN = inlet OUT = outlet 3

4 Electrical connection The unit must be connected by a qualified electrician. The national and international regulations for the installation of electrical equipment must be adhered to. Voltage supply to EN 50178, SELV, PELV. Disconnect power. Connect the unit as follows: 1 3 4 1 4 3 L+ L- For information about available sockets/connectors see: www.ifm.com Products Accessories 5 Switch point setting There are possibilities: Definition of requested value 5.1. Adjustment to existing flow 5.. 1 A B C D A: LED; B: setting screw; C: lock screw; D: setting scale Do not turn the setting screw beyond the maximum value of the setting range ( Technical data) to avoid faulty switching. 4

5.1 Definition of requested value Loosen the lock screw. Turn the setting screw until the requested value just becomes visible on the setting scale. Example in figure : requested value = 100 l/min. Tighten the lock screw. 5. Adjustment to existing flow Let the normal flow circulate in the installation. Loosen the lock screw. Set the switch point with the setting screw. -- If the LED lights before setting: turn the setting screw in the direction [+] until the LED goes out. Then turn in the opposite direction [-] until the LED lights. -- If the LED does not light before setting: turn the setting screw in the direction [-] until the LED lights. Tighten the lock screw. Correlation between number of the turns of the setting screw (SET) and switch point in l/min: One complete turn corresponds to approx. 18 l/min UK Q [l/min] 00 180 160 140 10 100 80 60 40 0 0 1 3 4 5 6 7 8 10 11 1 13 14 SET The diagram shows the typical course of the measurement curves for water at 0 C. 5

6 Operation After power on the unit is ready for operation. It detects the volumetric flow quantity and switches the output according to the setting. Function diagram Q A B t C 1 0 A = requested flow; B = switch point; C = switching output 7 Maintenance, repair and disposal In case of correct use no maintenance and repair measures are necessary. In case of strongly polluted media: mount a filter in front of the inlet (IN). Recommendation: use a 50-micron filter. Only the manufacturer is allowed to repair the unit. After use dispose of the unit in an environmentally friendly way in accordance with the applicable national regulations. 6

8 Scale drawing 56 11...17,5 UK Rp 1 Rp 1 0 0 11,5 137...146,5 dimensions are in millimeters 7

9 Technical data Setting range [l/min]...0...00 Flow range max. [l/min]...00 Operating voltage [V]... 4 DC (-15 % / +10 %) Current rating [ma]... 100 Protected against short circuits, reverse polarity and overload Voltage drop [V]...<.5 Current consumption [ma]...< 15 Hysteresis [l/min]...5...10 Repeatability [% of value of measuring range]...1 Accuracy [% of value of measuring range]...± 5 Response time [s]...< 0.01 Pressure loss (dp) / flow rate (Q) dp [bar] 0,8 0,7 0,6 0,5 0,4 0,3 0, 0,1 0 0 5 15 5 35 45 55 65 75 85 95 105 15 145 165 185 05 115 135 155 175 195 Q [l/min] Housing materials...brass chemically nickel-plated; aluminium anodised; PP Materials (wetted parts)... stainless steel (304S15); brass chemically nickel-plated; PP; O-ring: FPM (Viton) Protection... IP 67 III Switching cycles min.... 10 million Medium temperature [ C]... 0...85 Operating temperature [ C]... 0...60 Pressure resistance [bar]... 5 Further information at www.ifm.com 8