US-S/FFL. Ultrasonic energy meters. Function. Flexible design. Connection. Mounting. High reliability

Similar documents
WSTH/WPTH. Woltmann type combined energy meter. Measuring distance. Function. Connection. High reliability. Mounting.

WSTH/WPTH. Woltmann type combined energy meter. Woltmann flow meters for large nominal flows combined with calculator and temperature sensors.

SonoMeter 30 Energy Meters

RAY COMPACT ENERGY METER MECHANICAL

SonoMeter 30 Energy Meters

Supercal 539 Universal compact heat meter

RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from DN 15mm qp 0,6m3/h up to DN 40mm qp 10m3/h

Supercal 539. Compact thermal energy meter

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

SensoStar C. Installation and Operating Instructions Heat Meter Calculator Heat/Cooling Meter Calculator Cooling Meter Calculator

CORONA E ELECTRONIC METER MULTI-JET

CORONA ER ELECTRONIC METER MULTI-JET

Hello, I am the new Zelsius C5 heat meter. The new generation of ultrasonic heat and cooling meters for precise energy consumption measurement.

WZMC-402 Ultrasonic Apartment Energy Meters

Superstatic 749. Fluidic Oscillation Compact Heat Meter

Compact Static Heat Meter of High-Tech Composite

Fluidic Oscillation Compact Heat Meter

Fluidic Oscillation Compact Heat Meter of High-Tech Composite

IFX-M4-03 IFX-M4-03_D_E_2017_05_REV.0

HYDRUS ULTRASONIC METER

HYDRUS ULTRASONIC METER

Superstatic 440. Static Heat Meter, Static Cooling Meter. Application

Measuring capsule heat meter G54 / G55

Metering systems 0578EN January 2014 Thermal energy meters, ultrasounds type for use in a boiler room GE552-1 series

Superstatic 440. Static Heat- and Cooling Meter. Application

Datasheet PDCSY-MW-U. Technical Overview. Features. Product warranty and total quality commitment.

WESAN WPV E ELECTRONIC METER WOLTMAN

Heat Meter Integrator

EW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS

Screw-type and measuring capsule heat meter with IrDA interface and an interface for retrofitting external modules or with integrated communication.

WESAN WP 222. Bulk Water Meter Woltman

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

Heating and Cooling Catalog

ULTRASONIC HEAT METER

tprime TM Series 280T

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

SHARKY FS 473 ULTRASONIC FLOW SENSOR

aquaconcept Product features Customer benefits

Data sheet MULTICAL 6L2. Data loggers Info loggers Data backup in case of power failure MID-2004/22/EC EN 1434

MULTICAL 6M2. Data sheet

TOPAS PMW-basic. Customer benefits. Product features

Installation & Maintenance Instructions MULTICAL 403. Supplied by. .com. Call us on +44 (0)

EW130 Series Multijet Water Meters DN15 40 FOR COLD AND WARM POTABLE WATER APPLICATIONS

ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2

Residential. Ultrasonic Cooling Meter ULTRACOLD T350 (2WR6...) A customer tailored cooling meter designed for residential needs and easy billing

M-bus impeller type heat and heat/refrigeration meters

STUF-280W. Features: Ultrasonic Water Meter, DN15~DN40. Ultrasonic Water Meter DN50~DN600

Datasheet. Multical 402. (Heating & Cooling) Supplied by. .com. Call us on +44 (0)

ULTRASONIC METER FOR HEATING AND COOLING SKU-03

SonoSensor 30 Ultrasonic flow sensor

F 90 Heat Meter Warmly recommended to cool-headed economisers

Design and application

REQUIRED TOOLS 3 mm screw driver Wrench Crosstip screwdriver

WESAN WP WOLTMAN METER

zelsius Installation and operating manual All that counts. EnergyMetering

DC Energy Measurement for EV Charging Stations

HYDROMETER. Operating Instructions Edition 03/ Revision 05. Ultrasonic flowmeter type SHARKY 475 [ ] A5E HYDRO.PS.022.Q5.

LDX-U20 is a microprocessor controlled DC-UPS rated 20 A usable in 12 V or 24 V systems.

2- and 3-port valves with flanged connections, PN 16

Heating Cost Allocation Valve with local acquisition of the flow temperature

2- and 3-port valves with flanged connections, PN 16

CE DECLARATION OF CONFORMITY

Thermo-hygrometer-anemometer VT 210

GEMÜ 539 esydrive Motorized globe valve

zelsius Installation and operating manual All that counts EnergyMetering

Carbon Dioxide (CO2) + Humidity (rh) + Temperature (T) transmitter with Display for room mounting. Features

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

MJÖLNER 200 Microhmmeter

MULTICAL 602. & ULTRAFLOW 14 Cooling. Cooling meter with unlimited communication

HMM Series Mechanical Heat Meters

Thermo-hygrometer-anemometer VT 210

a q u a c o n c e p t Applications Features Benefits

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter

LIFT INVERTER SERIES L1000V DE ES FR IT 1000V L1000V L1000V L1000V L1000V

mass flowmeter for compressed air

DPI 620 Genii. Advanced Modular Calibrator and HART / Foundation Fieldbus Communicator. GE Measurement & Control

Handheld Micro Ohmmeters RMO-H series

Horizontal Distribution Units - HDU Multi-port

COUNTIS E22 Three-phase energy meter Direct - 80 A

PROVA 1011 Solar System Analyzer

Heat / Chill Meter PolluCom M Installation and Operating Instructions. PolluCom M. Installation and Operating Instructions. M H 1210 INT, Page 1

ebro has expanded its wide range of loggers in the food sector even further: ebro Data Logger Family EBI 20

Evaluation Certificate

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter

HUMIDITY / TEMPERATURE TRANSMITTER

Modulating control valves with magnetic actuator PN 16

SITRANS FUE950 *085R9430* Energy calculator type SITRANS FUE950. Operating Manual Edition 09/ Revision 03

Handheld Micro Ohmmeters RMO-H series

Technical Data. BiRotor Plus Positive Displacement Meter

JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor.

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

Paddle-wheel flow controller with optical principle for On/Off control

Paddle-wheel flow controller for On/Off control

Modulating Control Valve PN 16 with Magnetic Actuator

9142-B-P-156/AF. User s Guide. Field Metrology Well. Distribution is limited to DoD and U.S. DoD contractors only.

TOPAS PMW-basic Hot water meter

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

2-port seat valves PN16 with flanged connection

Compressed air counter DN

Solenoid Operator 0516 / 1216

Transcription:

Revision 2017-08-15 Ultrasonic energy meters Flanged ultrasonic energy meters, intended for heating or cooling. Size DN25 DN100 Nominal flow 3.5 60 m³/h For horizontal or vertical mounting No data loss when changing battery No moving parts enable flow measurement at low pressure drops Available with M-Bus, pulse output or M-Bus and 2 pulse inputs Function The menu system, available in the display, makes it possible to read a large number of parameters, such as heat and cold consumption, total energy spent on heating and cooling, temperatures along with current energy consumption. Installation is normally in the return pipe. Connection The energy meter comes equipped with two PT500 temperature sensors. The resistors for the sensors are composed of platinum and maintain a standard of DIN IEC 60751. Flexible design Due to the multiple combination options offered by its components, the meters can easily be adapted to suit a large number of individual requirements. Models with M-Bus, pulse output or M-Bus + pulse input are available. Energy meters with M-Bus have a default address of 0, which is not a valid primary communication address. This primary address can be changed by searching for secondary addresses (i.e. the ID number of the meter). Mounting Both temperature sensors have a cable length of 3 m. The calculator can be wall mounted or DIN-rail mounted. High reliability The meter offers reliable and accurate performance over long periods of measurement. The calculator features a high accuracy of measurement, in addition to a long life and robust design. The calculator utilizes EEPROM memory, meaning loss of data does not occur if the battery is changed. E-Mail: info@regin.se 1

Installation example, heating Temp. sensor 1 Forward flow (hot water) Heat source User Return flow (cool water) Temp. sensor 2 Flow meter Min. 2 DN Installation example, cooling Temp. sensor 1 Forward flow (cold water) Cooling source User Return flow (warm water) Temp. sensor 2 Flow meter Min. 2 DN E-Mail: info@regin.se 2

Revision 2017-08-15 Technical data, calculator Power supply 3.6 V lithium battery Temperature range 1...150 C Temperature difference limits 3...100 K (heating), -3...-50 K (cooling) Temperature resolution 0.01 C Ambient temperature 5...55 C Storage temperature -20 +60 C Ambient humidity < 93 % RH Protection class IP54 (heating), IP65 (cooling) Calculation of heat from K ΔΘ > 0.05 K Calculation of cooling from K ΔΘ < -0.05 K Dual purpose heat/cooling meter ΔΘHC < -0.5 K Measurement frequency at q p Cycle 30 s Data storage EEPROM, daily storage of values Interfaces M-Bus, pulse output or M-Bus with 2 pulse inputs Reading dates Annual billing date selectable, 24 monthly values Display LCD, 8 digits + additional symbols Display units MWh, kwh, GJ, m 3, m 3 /h, l/h, kw, MW, C Mechanical class Class M1 (MID: 31.03.2004 annex I) EMC Class E1 (MID: 31.03.2004 annex I) Environmental class A (EN 1434) Technical data, temperature sensor Cable length Sensor element Diameter, sensor Installation Temperature sensor requirements, heat meter Temperature sensor requirements, cooling meter 3 m PT500; separately approved type as per EN60751, unshielded 6 mm Direct or indirect in a temperature sensor pocket per EN1434 EU (MID) identification on the temperature sensors National German approval as a temperature sensor for cooling meters. Requirements in other countries may be different. Technical data, flow meter Connection Flanged according to EN 1092-3 Pressure rating Media Mounting position Mounting position, cooling Point of installation Temperature range Temperature range, heating PN25 Water Horizontal or vertical Transducers (black housing) to the side of or under the measuring tube Return flow Temperature range, cooling 5 50 C Recommended minimum system pressure 5 130 C (National approvals may differ.) 10 130 C (20 130 C for short versions) 1 bar (to avoid cavitation problems) Models Nominal Nominal Maximum Minimum Flow at 0.1 bar pressure Low flow Pressure drop Article diameter flow, q p flow, q s flow, q i drop threshold at q p 25-3.5 DN25 3.5 m 3 /h 7 m 3 /h 35 l/h 4.4 m 3 /h 14 l/h 60 mbar 25-6.0 DN25 6 m 3 /h 12 m 3 /h 60 l/h 4.4 m 3 /h 24 l/h 180 mbar 40-10 DN40 10 m 3 /h 20 m 3 /h 100 l/h 8.9 m 3 /h 40 l/h 130 mbar 50-15 DN50 15 m 3 /h 30 m 3 /h 150 l/h 13.3 m 3 /h 60 l/h 110 mbar 65-25 DN65 25 m 3 /h 50 m 3 /h 250 l/h 30 m 3 /h 100 l/h 105 mbar 80-40 DN80 40 m 3 /h 80 m 3 /h 400 l/h 36 m 3 /h 160 l/h 160 mbar 100-60 DN100 60 m 3 /h 120 m 3 /h 600 l/h 50.6 m 3 /h 240 l/h 115 mbar E-Mail: info@regin.se 3

CE Measuring Instruments Directive: This product conforms to the requirements of the Measuring Instruments Directive 2004/22/EC through product standards OIML R75, EN 1434, EN 60751, EN 14154 and PTB-Richtlinie K 7.1. Low Voltage Directive (LVD) standards: This product conforms to the requirements of the European Low Voltage Directive (LVD) 2006/95/EC through product standards EN 61140, VDE 0140-1, EN 60529 and DIN 40050. EMC emissions & immunity standards: This product conforms to the requirements of the EMC Directive 2004/108/EC through product standards EN 13757-2, EN 13757-3 and DIN 12900-1. RoHS: This product conforms to the Directive 2011/65/EU of the European Parliament and of the Council. Ordering code selection table Options - - Flow (DN) (length) (flange) 3.5 m 3 /h (DN25) (260 mm) (PN25 flange with 4 bolt holes) 25-3.5 6.0 m 3 /h (DN25) (260 mm) (PN25 flange with 4 bolt holes) 25-6.0 10 m 3 /h (DN40) (300 mm) (PN25 flange with 4 bolt holes) 40-10 15 m 3 /h (DN50) (270 mm) (PN25 flange with 4 bolt holes) 50-15 25 m 3 /h (DN65) (300 mm) (PN25 flange with 8 bolt holes) 65-25 40 m 3 /h (DN80) (300 mm) (PN25 flange with 8 bolt holes) 80-40 60 m 3 /h (DN100) (360 mm) (PN25 flange with 8 bolt holes) 100-60 Type of measurement and installation point Heating, installation of flow meter in return pipe (MID approval) -HR Cooling 1, installation of flow meter in return pipe -CR Heating and cooling in combination 2, installation of flow meter in return pipe -HCR Communication interface M-Bus -M M-Bus with 2 pulse inputs 3 Pulse output for energy -PO 1 National German approval. 2 MID approval for heating, not for cooling 3 The standard setting for the pulse counters is 1 l/pulse. Please contact Regin if other values (10 l/pulse or 100 l/pulse) are needed. If any further requirements or options are needed, please contact Regin. Example 1: Desired application: Meter with 10 m 3 /h. Heating, installation in return pipe. M-Bus. Resulting item ordering number: 40-10-HR-M Possible accessories needed: Sensor pockets (2 pcs): TH-85-½ -MPI Example 2: Desired application: Meter with 60 m 3 /h. Cooling, horizontal installation in return pipe. M-Bus + pulse input. Resulting item ordering number: 100-60-CR-MPI Possible accessories needed: Sensor pockets (2 pcs): TH-120-½ E-Mail: info@regin.se 4

Revision 2017-08-15 Accessories Temperature sensor pocket for installation of universal temperature sensor with 6 mm sheath diameter Article Connection A Compatible with Installation length TH-85-1/2 G½ q p 3.5 10 m 3 /h 85 mm TH-120-1/2 G½ q p 15 100 m 3 /h 120 mm Optical interface and read-out software Article OPTO-CABLE-USB OPTO-TOOL Description Optocoupler with USB interface Software device monitor Pressure drop curves 1 q p 3.5/6 10 15 25 40 60 Pressure drop [bar] 0.1 0.01 1 10 100 Flow [m 3 /h] E-Mail: info@regin.se 5

Dimensions Calculator 123.7 45.8 198 Flow meter q p (m 3 /h) PN bar DN a b øc ød øe No. of holes f g h 3.5 25 25 260 51 115 85 14 4 68 18 96 6.0 25 25 260 51 115 85 14 4 68 18 96 10 25 40 300 48 150 110 18 4 88 18 93 15 25 50 270 46 165 125 18 4 102 20 91 25 25 65 300 52 185 145 18 8 122 22 97 40 25 80 300 56 200 160 18 8 138 24 101 60 25 100 360 68 235 190 22 8 158 24 113 Measurements in mm unless otherwise specified. E-Mail: info@regin.se 6