QO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories

Similar documents
QO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers

Qwik-Gard Circuit Breakers With Ground Fault Circuit Interrupter 2P Common Trip. Discount Schedule DE2A

Selection Information Molded Case Circuit Breakers

1.5 INCH W X 2.91 INCH D X 3 INCH H

For the most up-to-date information

THERMAL-MAGNETIC/MAGNETIC ONLY MOLDED CASE CIRCUIT BREAKERS

EDB-EPD, EGB-EPD and EJB-EPD (Equipment Protection Device) Circuit Breakers for Ground Fault Protection in NF Panelboards

Class 0734, 0500 / Refer to Catalogs: 0734CT0201, 0500CT9702. PowerPact G-Frame 3P 100 A Thermal-Magnetic Circuit Breaker (600Y/347 Vac)

THERMAL-MAGNETIC/MAGNETIC ONLY MOLDED CASE CIRCUIT BREAKERS

THERMAL-MAGNETIC/MAGNETIC ONLY MOLDED CASE CIRCUIT BREAKERS

Selection Information Molded Case Circuit Breakers

28.1. NEMA Contactors and Starters. Contents. Contactors Non-Reversing and Reversing. Freedom Series. Product Description

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A

Taxonomies, Classifications, and Categories THERMAL MAGNETIC, COMMON TRIP, EQUIPMENT PROTECTOR

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

NEMA Contactors & Starters A200

6 L-frame 600 A, Thermal-magnetic (600 Vac)

Selection Information 7-2. Motor Circuit Protectors Automatic Switches Vdc Circuit Breakers 7-35

A200 NEMA Contactors and Starters A200

PD-Series Ground Fault Circuit Protection

June 2005 CN35 Electrically Held Vol. 2, Ref. No. [0494]

F-Series General Specifications

PB-Series. GFCI/ELCI & Panel Seal

209 Series. Magnetic Circuit Protectors

4.2. Definite Purpose Contactors and Starters. Contents A, Two-, Three- and Four-Pole C25. Contactors

SECTION PANELBOARDS

D I D /240 I. D x /240 I D / x x /24 I. D x /120

F-Series. Circuit Breaker

F-Series. Circuit Breaker

209/219/229/249/279 Series Magnetic Circuit Protectors

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Selection Guide. Control Circuit and Load Protection

For the most up-to-date information

Control Circuit Protection

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Selection Information 7-2. QO and QOU Miniature Circuit Breakers Multi 9 TM Miniature Circuit Breakers 7-16

Bulletin 1489 Circuit Breakers. Selection Guide

Motor Control. Contactors C 25 D N A 2 15 A A CATALOG SELECTION. Definite Purpose Contactors Catalog Numbering System. Contactors

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1

I-Line Circuit Breaker Panelboards Catalog 2110CT9701R02/ Class 2110

Tmax Molded Case Circuit Breakers

25.4. Molded Case Circuit Breakers. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents

.1 NM ontactors and Starters Product Overview starters and contactors feature a compact, space-saving design, using state-of-the-art technology and th

NEMA Contactors and Starters

AP/UP, AP/MIL Series Magnetic Circuit Protectors

1492-CB 1492-GH 1492-GS

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59.

Thermal-Magnetic For Mining Applications Class 600

Load Centers and Circuit Breakers

PowerPact B. Molded case circuit breakers and switches from A

NQOD Circuit Breaker Panelboards

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw

Bussmann series IEC cylindrical fuses

Circuit Breaker Accessories BREQS125 BRHDK125

High Speed Fuses. Section Contents Page

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

Open, NEMA Type 1, 3R, 4/4X and 12. Auxiliary Contacts

A. Submit manufacturer's literature and technical data before starting work.

5.11. Metering Products. Contents Description Systems for Residential and Commercial

Contactors & Starters. Definite Purpose. Definite Purpose Contactors & Starters C-1. Contents

F-Frame. January 2001 Vol. 1, Ref. No. [0586] Discount Symbol... CB-2. For more information contact Cutler-Hammer at:

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

Product Line Overview. The Most Logically Designed Contact Assembly

Phone: Fax: Web: -

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

Disconnect Switch and Circuit Breaker Mechanism Specifications Bulletin Number 1494

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB

GE 8000-Line Motor Control Centers Mains, Feeders, Incoming Lines C-1

The UL listed heart of the LynTec Lighting Control and Sound Sequencing Panels

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers

Single Pole Circuit Protectors 67 Multi-Pole Circuit Protectors 68 Printed Circuit Board Mounting 70 Configurations 72 Operating Characteristics 73

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

Series L9 UL-489 Miniature Circuit Breakers

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

1489-M Circuit Breakers

Tmax Molded Case Circuit Breakers

2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.

JAE Series. Magnetic Circuit Protectors. Introduction Poles Configurations Operating Characteristics Delay Curves Decision Tables

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta

G-Series. Circuit Breaker.

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

Horizontal Circuit Switchers

Definite Purpose Control. Product Focus

NEHB Circuit Breaker Panelboards. For 480Y /277V. ac Systems

RY2L Series Miniature Magnetic Latching Relays. E Release Time. 60N (0 6G); Maximum frequency 55Hz

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD

UL 489/CSA C22.2 No. 5 Listed C60 Circuit Breakers 1.22 [31.1] 1.77 [45.1] 4.86 [123.4] Clearance 1.77 [45]

NQOD Circuit Breaker Panelboards

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

NEMA Contactors and Starters

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame

Specifications. S&C Omni-Rupter Switches Outdoor Distribution (14.4 kv and 25 kv) Conditions of Sale

TeSys GV2 - GV3 Manual Starters and Protectors

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.

Transcription:

QO and Miniature ircuit reakers QO ircuit reaker ccessories lass 1130 / Refer to atalog 0730T9801 IRUIT RKRS ccessories for Use with QO and QO Miniature ircuit reakers Handle ttachments escription at. No. onverts any two adjacent 120/240 Vac 1P QO circuit breakers to independent trip 2P QO1HT Handle Tie: onverts any two adjacent 120/240 Vac 1P side-by-side QOT circuit breakers to independent trip 2P QOTHT Handle tie and lock-off for three 1P QO, QO circuit breakers QO3HT Handle lamp: lamp for holding QO 1P handle in ON or OFF position QO1LO lamp for holding QO or Q1 1P, 2P or 3P circuit breaker handles in ON or OFF position HLO1 For padlocking 1P QO circuit breaker in ON or OFF position Loose attachment QOHPL Fixed attachment QO1P Handle Padlock ttachment: for For padlocking 1P side-by-side QOT circuit breaker in ON or OFF position QOTHP Padlocking in ON or OFF position For padlocking 2P and 3P QO-FI, QO-P, and QO-P in either ON or OFF position, fixed attachment. FI2P For 2P and 3P QO and Q1 standard circuit breakers which require padlocking in either ON or OFF position. Loose attachment QO1HPL Fixed attachment QO1PL For padlocking 1P QO circuit breaker in OFF position only, fixed attachment. QO1PF Handle Padlock ttachment: for For padlocking 2P and 3P QO circuit breakers in OFF position only, fixed attachment. QO2PF Padlocking in OFF position For padlocking 1P QO-FI, QO-FI, QO-FI, and QO-P circuit breakers in OFF position only, fixed attachment. QOFI1PF For padlocking 2P and 3P QO-FI, QO-P, and QO-P circuit breakers in OFF position only, fixed attachment. QOFI2PF Sub-Feed Lugs 60 2P plug-on 2 spaces required (6 2 l/u) QO60SL 125 2P plug-on 2 spaces required (12 2/0 l/u) QO2125SL 225 2P plug-on 4 spaces required (4 300 l/u) QO2225SLa 125 3P plug-on 3 spaces required (12 2/0 l/u) QO3125SL Mechanical Interlock ttachment For interlocking the handles of two 2P or one 2P and one 1P QO and Q1 circuit breakers mounted side-by-side so that only one circuit breaker can be ON at a time (Not ) QO2TI With Retaining Kit: QO2TI mechanical interlock attachment with retaining kits for securing two adjacent back-fed circuit breakers in dual power supply applications. an be used with (2) 2Ps or (1) 2P and (1) 1P QO circuit breakers in QO816L100 load centers. QO2TIM a Not suitable for use in 3Ø panels. Use only in 1Ø panel rated 150 or greater. 3 QO1P QO1PL QO1HT QO1LO QO1PF HLO1 QO2TI QO1HPL QOTHP QO2PF QOFI2PF QOHPL Factory-Installed ccessories ccessory Shunt Trip escription Factory-Installed ccessories for Use with QO and QO Miniature ircuit reakers Factory-installed electrical accessories take up an additional pole space on QO, QO-FI, QO-P, QO-SWN and circuit breakers. ll electrical accessories shown below are rated for 50/60 Hz. ccessories are not available for QO-VH (2P 150 and 3P 110 150 ) circuit breakers or QO, molded case switches. QO circuit breakers will accept only one accessory per circuit breaker. Undervoltage trip is not available on miniature circuit breakers. Factoryinstalled accessories are not available for QO-FI or QO-FI rc Fault ircuit reakers or on QO2150, QO2175, or QO2200 circuit breakers. Rated Voltage oil at. No. urden Suffix Trips the circuit breaker from a remote location by means of a trip / 12 60 V -1042 24 168 V coil energized from a separate circuit. 120 Vac shunt trip will 120 72 V operate at 55% or more of rated voltage. ll other shunt trips will operate at 75% or more of rated voltage. pplication For use with momentary or maintained push button. Not available on QO-FI, QO-P, QO-FI, QOFI. Shunt trip terminals accept (2) 14 12 W u. 208 240 228 V 288 V -1021 dder ccessory uxiliary Switches larm Switches escription Monitors circuit breaker contact status and provides a remote signal indicating the circuit breaker contacts are OPN or LOS. pplication uxiliary switch terminals accept (2) 14 12 W u leads. Used with control circuits and is actuated only when the circuit breaker has tripped. Standard construction includes a normallyopen contact. pplication larm switch terminals accept (2) 14 12 W u leads. ontact omb. 1 1 Max. Voltage 120 120 Max. Load 5 5 at. No. Suffix -1200-1201 1 120 5-2100 dder 3-12 06/12

QO and Miniature ircuit reakers Miniature ircuit reakers lass 720 / Refer to atalog 0730T9801 Low mpere Miniature ircuit reakers unit mount miniature circuit breakers (cable-in/cable-out) are ideal for OM applications. They have the Square circuit breaker s unique Visi-Trip feature and can be IN rail-mounted or surface- or flush-mounted using mounting feet. Low mpere eneral Specifications ommon to ll Low mpere ircuit reakers For convenient flush mount, surface mount or IN mount S/UL Listed 48 Vdc (5 k IR) (symmetrical rail 35 x 7.5 IN/N 50 022) S/UL Listed as HR Type: 10 70 Single handle with internal common trip High magnetic trip circuit breakers (-HM) are recommended Terminal lug wire size (1) 14 2 W u or l for applications where high initial inrush may occur and for Reversible line and load lugs individual dimmer applications. Field-installable quick connectors IRUIT RKRS 3 Low mpere Miniature ircuit reakers mpere 1P 120/240 Vac 2P 120/240 Vac 2P 240 Vac 3P 240 Vac at. No. at. No. at. No.a at. No. 10 k IR 10 110 210 310 15 115 215 215H 315 20 120 220 220H 320 25 125 225 225H 325 30 130 230 230H 330 35 135 235 335 40 140 240 340 45 145 245 345 50 150 250 350 60 160 260 360 70 170 270 370 22 k IR 15 115VH 215VH 315VH 20 120VH 220VH 320VH 25 125VH 225VH 325VH 30 130VH 230VH 330VH 35 135VH 235VH 40 140VH 240VH 45 145VH 245VH 50 150VH 250VH 60 160VH 260VH a -H interrupting rating is 10 k at 240 Vac. -HM Miniature ircuit reakers (10 k IR) mpere 1P 120/240 Vac 2P 120/240 Vac 2P 240 Vac 3P 240 Vac at. No. at. No. at. No. at. No. 15 115HM 20 120HM High mpere High mpere ircuit reakers eneral Specifications ommon to ll High mpere ircuit reakers Flush mount, surface mount, and IN rail mount. S/UL Listed as HR type, 80 125. Internal common trip. Non-automatic switches have the same physical packaging Non-reversible line and load lugs. as miniature circuit breakers, but provide no overcurrent or Terminal lug wire size (1) 12 2/0 W u or l. short circuit protection. They are UL Listed per UL1087 and UL Listed 60 Vdc per pole (5 k IR). (Note: except switches) are S certified. High mpere Miniature ircuit reakers (10 k IR) mpere 1P 120/240 Vac 2P 120/240 Vac 2P 240 Vac 3P 240 Vac at. No. at. No. at. No. at. No. 80 180 280 380 90 190 290 390 100 1100 2100 3100 125 2125 Non-utomatic Switches mpere 1P 120 Vac 2P 120/240 Vac 2P 240 Vac 3P 240 Vac at. No. at. No. at. No. at. No. 60 200 300 100 2000 3000 125 20001 30001 Interrupting s................................... Page 3-3 ccessories................................. Page 3-12, 3-15 imensions......................................... Page 3-54 3-14 06/12

imensions and Shipping Weights Miniature and Molded ase ircuit reakers IRUIT RKRS Figure 1 Figure 6 Figure 4 Figure 2 Figure 7 Figure 5 Figure 8 Figure 3, QYU Low mpere QO, QO QO-FI, QO-PL QO-P F QO,, Multi 9 ircuit reakers ircuit reaker atalogue No. Prefix QO, QO QO-VH 150 QO-VH 110 150 QO-PL QO-FI QO-P Low mpere High mpere Multi 9 60 a b c d e f No. Poles Fig. No. imensionsinches F 1 1 0.75 3.00a 2.31 2.91 2.25... 0.59 2 2 1.50 3.00a 2.31 2.91 2.25... 1.34 3 3 2.25 3.00a 2.31 2.91 2.25... 2.09 2 2 3.0 5.72 2.53 4.90 3.78... 2.85 3 3 4.50 5.72 2.53 4.90 3.78... 4.35 1 4 0.75 4.12b 2.31 2.91 2.25... 0.59 2 5 1.50 4.12b 2.31 2.91 2.25... 1.34 3 5 2.25 4.12b 2.31 2.91 2.25... 2.09 1 6 0.75 4.05c 2.38 2.98 2.25 5.00p 0.62 2 7 1.50 4.05c 2.38 2.98 2.25 5.00p 1.37 3 8 2.25 4.05d 2.38 2.98 2.25 5.00f 2.12 1 9 0.75 4.45 2.37 2.96 2.25 6.78... 2 10 1.50 4.45 2.37 2.96 2.25 6.78... 3 11 2.25 4.45 2.37 2.96 2.25 6.78... 1 13 0.71 3.19 1.73 2.76 1.77 2 14 1.42 3.19 1.73 2.76 1.77 3 15 2.13 3.19 1.73 2.76 1.77 4 16 2.84 3.19 1.73 2.76 1.77 35 70 is 3.12 in; 80 100 2-pole and 70 100 3-pole are 3.50 in. QO-PL is 4.55 in. 80 100 1-pole and 80 125 2-pole are 4.45 in. 70 100 4.45 in. 80 100 1-pole and 80 125 2-pole are 6.78 in. 70 100 is 6.78 in. 3 Figure 9 Figure 10 Figure 11 Figure 10 Figure 13 Figure 14 Figure 11 Figure 15 Figure 12 Figure 16 High mpere F 60 Q, Q, Q, QJ, Q4, F, FI, KI, L, LH ircuit reakers ircuit reaker atalogue No. No. Prefix Poles Fig. imensionsinches No. F H Q, Q, 2 22 6.47 3.00 3.02 3.93 g 4.25...... Q, QJ 3 23 6.47 4.50 3.02 3.93 g 4.25 1.50 0.75 1 21 6.00 1.50 3.16 4.13 0.44 5.13 1.50... FL, FHL 2 22 6.00 3.00 3.16 4.13 0.44 5.13...... 3 23 6.00 4.50 3.16 4.13 0.44 5.13 1.50 0.75 FIL, KIL 2 & 3 23 8.00 4.50 3.66 4.75 0.44 7.13 1.50 0.75 Q4L, LL, LHL 2 & 3 23 11.00 6.00 4.06 5.84 0.88 9.25 2.00 1.00 g imensions are 1.59 in at ON end and 0.63 in at OFF end. Shipping Weightsh Frame Size pprox. Shipping Weight (Lbs.) Frame Size pprox. Shipping Weight (Lbs.) Figure 17 Figure 18 Figure 19 Figure 20 FL, FHL 1P 2 KIL 9 FL, FHL 2P 3 LL, LHL 15 FL, FHL 3P 5 LIL LXIL 25 FIL 8 Q4L 15 Q, Q, Q, QJ 4 h ll weights are for 3P circuit breakers unless otherwise noted. Figure 21 F Figure 22 /L F Figure 23 HH /L F Figure 24 F 3-54 06/12

Miniature ircuit reakers and Switches pplication Information Table 1: Selection ata Tripping Mechanisms atalog Number One-Pole Two-Pole Three-Pole 120/240 Vac 120/240 Vac 240 Vac 120/240 Vac 240 Vac 10K IR 22K IR 10 K IR 22K IR 10K IR 10 15 15 20 20 25 30 35 40 45 50 60 110 115* 115HM* 120* 120HM* 125* 130* 135* 140* 145* 150* 160* 115VH 120VH 125VH 130VH 135VH 140VH 145VH 150VH 160VH 70 170* 80 180 90 190 100 1100 125 Switch60 mperes Max.240 Vac Switch100 mperes Max.240 Vac Switch125 mperes Max.240 Vac 210 215* 220* 225* 230* 235* 240* 245* 250* 260* 270* 280 290 2100 2125 Terminal Lug Wire Size (W) 215H* 220H* 225H* 230H* 215VH 220VH 225VH 230VH 235VH 240VH 245VH 250VH 260VH 310 315* 320* 325* 330* 335* 340* 345* 350* 360* 1#14 #2 u or l 370 380 390 1#12 #2/0 3100 u or l 200 300 1#14 #2 2000 20001 30001 1#12 #2/0 * UL Listed as HR type for use with heating, air conditioning and refrigeration equipment containing motor-group combinations and marked for use with HR type circuit breakers. High-magnetic trip circuit breakers. Recommended for applications where high initial inrush current can occur and for individual dimmer applications. vailable as Series 1 with forward box lugs only. (No optional terminations) tripping mechanism is an assembly within the circuit breaker molded case that causes the circuit breaker to open automatically under sustained overload or short circuit conditions. The tripping mechanisms in two- and three-pole circuit breakers operate such that an overcurrent on any pole of the circuit breaker will cause all poles of the circuit breaker to open simultaneously. Thermal and magnetic factory calibration (with current) is performed on each pole of every Square circuit breaker. These mechanisms operate to trip the circuit breaker: Thermal trip Magnetic trip Optional shunt trip accessory (see ccessories, page 12) The sensing system is an integral part of a thermal-magnetic circuit breaker. The sensing system continually monitors current flowing through the circuit breaker. It detects abnormal current conditions and, depending on the magnitude of the current, initiates an inverse-time or an instantaneous tripping response. This action causes the tripping mechanism to open the circuit breaker contacts and interrupt current flow. The speed of the tripping process must be controllable and inversely matched to the severity of the overcurrent. miniature circuit breakers have an over-center toggle mechanism for quick-make, quick-break action with positive handle indication. The handle assumes a position between ON (I) and OFF (O) when the circuit breaker has tripped. 09/2005 2005 Schneider lectric ll Rights Reserved 3 ourtesy of Steven ngineering, Inc. 230 Ryan Way, South San Francisco, 94080-6370 eneral Inquiries: (800) 670-4183 www.stevenengineering.com

Miniature ircuit reakers and Switches pplication Information Line and Load onnections miniature circuit breakers are supplied with two types of lug configuration as standard, depending on the continuous current rating: 10 70 ampere one- and two-pole; reversible lugs 10 60 ampere three-pole; reversible lugs Other ampere ratings; forward lugs only The box-type lugs supplied on miniature circuit breakers are UL Listed and S certified to accept solid or stranded, aluminum or copper conductors These lugs are UL Listed to be used with wire rated at 140 F, 167 F and 194 F (60, 75 and 90 ), sized according to the N 176 F (75 ) temperature rating. See the ccessories section for more information on terminations. Optional terminations, such as quick connectors, are also available. See the ccessories section for more information on terminations. Ring-tongue terminals can be factory ordered using the following catalog number designations: _3100 (ring-tongue terminal wired from front) R _5283 (ring-tongue terminal wired from rear) Mounting Provisions miniature circuit breakers are supplied with mounting brackets for both line and load side support. Mounting brackets are field installable and can be attached to the front or back of the circuit breaker molded case. See the ccessories section for more information on mounting brackets. Tapped mounting feet can be ordered using the catalog number designation _3100. ll miniature circuit breakers also come equipped with slots in the molded case for IN rail mounting. These miniature circuit breakers are designed for use with a standard 35 mm IN mounting rail (IN/U 50 022, 0.30 x 1.38 in. [7.5 mm x 35 mm]). Standards Square brand miniature circuit breakers are manufactured and tested according to the following standards: UL Standard 489 (File 84967) NM Standard 1 anadian Standards ssociation S 22.2 No. 5-02 I 60947-2 Square brand non-automatic switches comply with: UL Standard 489 anadian Standards ssociation S 22.2 No. 5-02 NOT: ircuit breakers are to be applied by guidelines detailed in the N and other applicable electrical codes. 09/2005 2005 Schneider lectric ll Rights Reserved 5 ourtesy of Steven ngineering, Inc. 230 Ryan Way, South San Francisco, 94080-6370 eneral Inquiries: (800) 670-4183 www.stevenengineering.com

Miniature ircuit reakers and Switches pplication Information atalog Numbers Square brand circuit breakers are ordered by a catalog number that includes the circuit breaker family, description, number of poles, amperage rating and suffix. Table 2: atalog Numbers Typical atalog Number: QO U 2 30 H 2100 QO Miniature ircuit reaker Family escription U Unit Mounted (Lugs on oth nds) No. of Poles 1 1-pole 2 2-pole 3 3-pole mpere 10 125 mpere 00 = 60, 000 = 100, and 0001-125 Switch 1- and 2-pole 2-pole 3-pole No Letter-Standard 120/240 Vac VH - 22,000 IR No Letter - 240 Vac VH - 22,000 IR H-240 Vac VH - 22,000 IR Suffix XXX (i.e., 2100) - Indicates Factory-installed ccessory (See page 12) s for Miniature ircuit reakers When designing an electrical distribution system, overcurrent protective devices are generally selected based on performance requirements. Factors influencing this selection include system voltage, continuous current, interrupting rating and frequency. circuit breakers are selected by their ratings. circuit breaker s rating must meet or exceed the parameters of the electrical system on which they are used. Voltage circuit breaker can be rated for alternating current (ac) or direct current (dc) or both. The established voltage rating of a circuit breaker is based on design parameters such as clearance of current carrying parts and dielectric withstand tests both through air and over surfaces. Voltage ratings indicate the maximum voltage for the electrical system on which the circuit breaker can be applied. The circuit breaker must have a voltage rating greater than or equal to the system voltage. When a circuit breaker clears an overcurrent, it does so in two steps: First, the current sensing system identifies the overcurrent and releases the tripping mechanism. This results in a parting of the contacts. Then the circuit breaker must extinguish the voltage arc across the contacts. If the circuit breaker has the correct voltage rating, it can efficiently extinguish this voltage arc. miniature circuit breakers are rated in the following UL 489 voltages, as shown in Table 3: 120/240 Vac 240 Vac 48 Vdc 60 Vdc 277 Vac for QYU, UL 1077 recognized supplementary protector only (not a branch circuit breaker) 6 2005 Schneider lectric ll Rights Reserved 09/2005 ourtesy of Steven ngineering, Inc. 230 Ryan Way, South San Francisco, 94080-6370 eneral Inquiries: (800) 670-4183 www.stevenengineering.com

Miniature ircuit reakers and Switches pplication Information Interrupting The interrupting rating of a circuit breaker is the highest current at rated voltage that the circuit breaker is intended to interrupt under standard test conditions. ircuit breakers must be chosen with interrupting ratings equal to or greater than the maximum available short-circuit current at the point where the circuit breaker is applied in the system (See Table 3). Table 3: Interrupting 1 ircuit reaker Type ontinuous urrent The continuous current rating of a circuit breaker is defined by the National lectrical Manufacturers ssociation (NM) as: The maximum direct current or rms current, in amperes, at rated frequency which a device or assembly will carry continuously without exceeding the specified limits of observable temperature rise. Sometimes referred to as the ampere rating or handle rating of the circuit breaker, the continuous current rating relates to the system current flow under normal conditions. UL Standard 489 states that circuit breakers must carry 100% of their continuous current rating indefinitely (without tripping) at 104 F (40 ) in free air. circuit breakers should be applied, per the N, to carry 80% of their continuous current ratings in the intended enclosure. The continuous current rating is indicated on the handle of each circuit breaker. See Table 1. Switching uty No. of Poles mpere ratings do not apply to circuit breakers rated for 10 UL Listed Interrupting RMS Sym. mperes Volts Volts 1 120/240 240 277 48 60 10 30 N N 5 k 1 10 70 10 k N N 5 k N 80 100 10 k N N N 5 k 10 70 10 k N N 5 k N 2 80 125 10 k N N N 5 k 10 70 N 10 k N 5 k N 3 80 100 N 10 k N N 5 k -H 2 15 30 N 10 k N 5 k N -VH 2 15 60 22 k N N 5 k N N = Not pplicable The switching duty (SW) listing applies only to 15 and 20 circuit breakers rated at 277 Vac or less. The circuit breakers are subjected to specified temperature rise tests at predetermined periods during the endurance operations. 09/2005 2005 Schneider lectric ll Rights Reserved 7 ourtesy of Steven ngineering, Inc. 230 Ryan Way, South San Francisco, 94080-6370 eneral Inquiries: (800) 670-4183 www.stevenengineering.com