ACCESSORY KIT INSTALLATION INSTRUCTIONS

Similar documents
ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS Low Ambient Accessory For Air Cooled Split System Air Conditioners HB 180/240, HF -15,-20 Models Only

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTION

LOW AMBIENT ACCESSORY INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTIONS CMH-21 Low Ambient 460V Fan Speed Control

ACCESSORY KIT INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS CMH-7A LOW AMBIENT CONTROL

NL SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (R-410A, STYLE B)

B2HZ SERIES - 13 SEER SINGLE PACKAGED HEAT PUMPS (R-410A, STYLE A,B)

Installation Instructions

PREMIUM SERIES 22 SEER SINGLE SPLIT DUCTLESS, COOLING SYSTEMS (CONTAINS INDOOR AND OUTDOOR MODELS)

E4FH, E5FH SERIES 12 SEER HEAT PUMP

E1RA, E2RA SERIES - 10 SEER, 1PH & 3PH HEAT PUMP- OUTDOOR UNIT

ACCESSORY KIT INSTALLATION INSTRUCTIONS

REPAIR PART INSTALLATION INSTRUCTIONS

LX SERIES 16 SEER SINGLE SPLIT DUCTLESS, HEAT PUMP SYSTEMS (CONTAINS INDOOR AND OUTDOOR MODELS)

PREMIUM SERIES 22 SEER SINGLE SPLIT DUCTLESS, HEAT PUMP SYSTEMS (CONTAINS INDOOR AND OUTDOOR MODELS)

PREMIUM SERIES 22 SEER SINGLE SPLIT DUCTLESS, HEAT PUMP SYSTEMS (CONTAINS INDOOR AND OUTDOOR MODELS)

H*BA SERIES, 10 SEER, 1PH & 3PH AIR CONDITIONER- OUTDOOR UNIT

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

ACCESSORY KIT INSTALLATION INSTRUCTIONS

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

ACCESSORY KIT INSTALLATION INSTRUCTIONS

LX SERIES 16 SEER MULTI-SPLIT DUCTLESS, HEAT PUMPS

DX11S Commercial & 10-Ton, Three-Phase. Cooling Capacity: 88, ,000 BTU/h

INSTALLATION INSTRUCTIONS FOR EGA AND EGH SERIES ELECTRIC HEATERS IN V OR H SERIES UNITS

ELECTRIC HEAT ACCESSORY INSTALLATION INSTRUCTION. 20, 30 & 40 kw for 15 Ton Split System Air Conditioners Models: LB180 & LL A-0102

REPLACEMENT PARTS MANUAL

LX SERIES 16 SEER MULTI-SPLIT DUCTLESS, HEAT PUMPS

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

Models: WL302, WL372. Contents. Control Panel. Blower Assembly. Bard Manufacturing Company, Inc. Bryan, Ohio 43506

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

ACCESSORY KIT INSTALLATION MANUAL

Replacement Parts List

Installation Instructions

SPLIT TYPE AIR CONDITIONER. CASSETTE type. Models Indoor unit Outdoor unit MC24Y3E

WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL W30A1, W36A1. Models: Contents. General Notes. Important.

Replacement Parts Catalog

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL WH301 WH361. Models: Contents. General Notes. Important. Description

REPLACEMENT PARTS MANUAL

Models: W30A2, W36A2. Contents. Control Panel. Blower Assembly. Bard Manufacturing Company, Inc. Bryan, Ohio 43506

Replacement Parts Catalog

NM1250R SERVICE PARTS

Predator Model Number Nomenclature

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard CH Series 3, 4, & 5 Ton Wall Mount Heat Pumps

F2FP (G), F3FP (TG) SERIES FAN COIL UNIT

REPLACEMENT PARTS MANUAL

WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL. Models: W42A1 W42A1D W48A1 W48A1D W60A1 W60A1D. General Notes. Contents.

INSTALLATION INSTRUCTION ELECTRIC HEATER ACCESSORY MODELS 2NH THRU 2NH045025, 2NP THRU 2NP045025, 2ND , AND 2NX GENERAL

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT

DZ14S Commercial 3-5 TON, THREE-PHASE SPLIT SYSTEM HEAT PUMP 14 SEER / R-410A

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

INSTALLATION INSTRUCTIONS

REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE HEAT PUMPS. Models: W30H1 W36H1. Contents. General Notes. Important. Description

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTION ELECTRIC HEATER ACCESSORY MODELS 2NH THRU 2NH045025, 2NP THRU 2NP045025, 2ND , AND 2NX GENERAL

Installation Instructions

Parts List, Charging Chart, Wiring Diagram

INSTALLATION INSTRUCTIONS

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES

REPLACEMENT PARTS MANUAL

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

REPLACEMENT PARTS MANUAL

FAST-STAT. Model 3000 Installation Instructions. Application. Troubleshooting not operating. Before Installing This Product. Sender Installation

PHE4 SERIES - 14 SEER SINGLE PACKAGED ELECTRIC HEAT PUMP (R-410A, STYLE A)

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS

ACCESSORY KIT INSTALLATION INSTRUCTIONS

CHILLER MODEL NO. YS SOLID STATE STARTER, MODEL NO. SSS, L B OPTIONAL FACTORY INSTALLED DISCONNECT SWITCH AMPS OR

WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL WA302, WA372. Models: Contents. General Notes. Important.

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard C**H Series 2 & 2½ Ton 2-Stage Wall Mount Heat Pumps

REPAIR PARTS. PTC/PTH Packaged Terminal Air Conditioners and Heat Pumps P R PTC154B50BM P R PTC124B50AM.

INSTALLATION INSTRUCTIONS

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL. General Notes. Contents. Important MODEL: WH381 WH431 WH491

ELECTRICAL 2 6 BOARD, CONTROL CAP, RUN, 50.0/5.0MFD [1RC]

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL. Models: SH381 SH431 SH491. Contents. General Notes. Important

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL. Models: S38H1 W38H1 S43H1 W43H1 S49H1 W49H1 S61H1 W61H1. General Notes. Contents.

SUBMITTAL DATA SHEET FEATURES. SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15, 20 & 25 TONS MODELS: J07 thru 25NC, 2-PIPE J10 thru 20ND, 4-PIPE

WATER SOURCE HEAT PUMPS REPLACEMENT PARTS MANUAL MODELS: General Notes. Contents. Important

Parts Lists. Forward Series. Rev. Feb. 2017

DESCRIPTION FEATURES

FM800R SERVICE PARTS

REPLACEMENT PARTS MANUAL

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz) Models Indoor unit Outdoor unit C O N T E N T S

REPLACEMENT PARTS MANUAL

CoolWave 2 Phase Control Board and Cable Replacement Kit

ACCESSORY KIT INSTALLATION INSTRUCTIONS

REPAIR PARTS. HDP Horizontal Discharge Heat Pumps HDP12-1 HDP12-1A HDP18-1 HDP18-1A HDP24-1 HDP24-1A. RP - 211G May 2004 This manual replaces RP-211G.

Models: Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage Lists... 4 " Usage Lists... 5 " Usage Lists...

P66 Series Electronic Fan Speed Controls

Contents. Burner Components. Control Panel. Blower Assembly. Bard Manufacturing Company, Inc. Bryan, Ohio 43506

SERVICE MANUAL TAC-600 SPARE PARTS FOR AIR CONDITIONER MODELS ANS ANS 50 ANS 60 ANS 65 ANS 77 ANS OCT ELECTRONIC CONTROL

REPLACEMENT PARTS MANUAL

Transcription:

ACCESSORY KIT INSTALLATION INSTRUCTIONS Low Ambient Accessory For Air Cooled Split-System Air Conditioners (H5CE180/240, HEHB180/240 and J15/20H5CE odels Only) 350160-UAI-B-0709 GENERAL Standard split-system condensing units are designed to operate at ambient temperatures down to 45 F. To operate safely at ambient temperatures down to 0 F, a low ambient accessory will be required. This instruction provides all the necessary information to properly field-install a low ambient accessory on the condensing units listed above. Components that are supplied in the respective accessory are listed in Table 2. Before starting the installation, check the voltage of the respective kit to be sure it matches the voltage of the unit. Refer to Table 1 for application data. WIRE IN ACCORDANCE WITH ALL LOCAL AND N.E.C. CLASS 1 WIRING REQUIREENTS. TABLE 1: APPLICATION DATA ACCESSORY ODEL # LINE VOLTAGE 2LA04704625 208/230 2LA04704646 460 2LA04704658 575 TABLE 2: ACCESSORY COPONENTS ODEL QTY. DESCRIPTION 2 otor, 1 hp 208-230 V 2 Johnson Controls P66 1 ounting Bracket 1 Installation Instruction 1 Low Ambient Switch (0 F) 2LA04704625 Bagged for Field Installation 3 Bushing, 1-3/8 6 Wire Tie 9 Screw, #10 1 Schrader Tee 1 Seal Cap Summary: Kit has two motors, two control assemblies, mounting bracket, Installation Instructions, one low ambient switch (0 F) and bag of parts listed above. TABLE 2: ACCESSORY COPONENTS (CONT.) ODEL QTY. DESCRIPTION 2 otor, 1 hp 460 V 2 Johnson Controls P66 1 ounting Bracket 1 Installation Instruction 1 Low Ambient Switch (0 F) 2LA04704646 Bagged for Field Installation 3 Bushing, 1-3/8 6 Wire Tie 9 Screw, #10 1 Schrader Tee 1 Seal Cap Summary: Kit has two motors, two control assemblies, mounting bracket, Installation Instructions, one low ambient switch (0 F) and bag of parts listed above. ODEL QTY. DESCRIPTION 2 otor, 1 hp 460 V 2 Johnson Controls P66 1 Transformer 575/460 V 1 ounting Bracket 1 Installation Instruction 1 Low Ambient Switch (0 F) 2LA04704658 Bagged for Field Installation 4 Bushing, 1-3/8 6 Wire Tie 9 Screw, #10 1 Wire Nut (c063) 1 Schrader Tee 1 Seal Cap Summary: Kit has two motors, two control assemblies, one transformer, mounting bracket, Installation Instructions, one low ambient switch (0 F) and bag of parts listed above. The 2LA047 series low ambient accessories are intended for use with the 15-20 Ton Split-System 2- Pipe Condensing Units only. Unitary Products cannot guarantee proper operation for any application of this P66 controller for other equipment or applications. Contact your local branch or distributor for any application related questions. Johnson Controls Unitary Products

Improper installation, adjustment, service or maintenance can cause injury or property damage. Therefore, only a qualified installer or qualified service personnel should perform this conversion. If the unit is connected to power sources, make sure that all electrical power to the unit has been disconnected. INSTALLATION A separate control is required for each outdoor fan motor. On 575V accessories, one buck/boost transformer powers both outdoor fan motors to allow the use of 460V motors in a 575V unit. 1. Disconnect the electrical power to the unit. 2. Remove all access panels and fan grilles. OUTDOOR FAN OTORS 1. Disconnect all outdoor fan motor leads and remove both motors through the top of the unit. 2. Install the motor provided in this accessory. The projections on the sides of the motors should rest on top of the motor mount band. The top of the fan blade should be about an inch below the top of the unit top cover. 3. Use wire ties to route the motor leads along the motor mount arm. Allow a drip loop in the motor leads at the motor so that the leads enter the motor upward. The drip loop prevents water from traveling along the wire into the motor. OUNTING CONTROLS 1. ount the head pressure control with the PURPLE wire labeled 700 on the outside of the unit on the front center post. Use the mounting bracket to keep the control out of the way of the access panels. ount the control with the PURPLE wire labeled 702 on the right front corner post. 2. Remove both knock outs below each control. 3. Insert a plastic bushing in the center partition separating the two fans to route the capillary tubes from the controls to the compressors. 4. Insert the plastic bushing in the hole closest to the control. Insert the capillary tube through the plastic bushing and tighten the flare nut onto the compressor discharge line flare fitting. Install the left capillary tube on the left compressor and the right capillary tube on the right compressor. 5. Insert the wiring through the second hole below the control and secure the conduit. 6. On 575V units, remove the knock out in the lower portion of the right front corner post and install a plastic bushing. Install the buck/boost transformer on the right front corner post, inserting the wires through the bushing. REPLACING LOW ABIENT SWITCH 1. Remove and discard 45 F low ambient switch (LAS). 2. Replace with 0 F low ambient switch provided in kit. 208/230 AND 460 VOLT UNITS WIRING HPC1 1. Refer to the wiring diagram in Figure 1 for connection of the Johnson Controls P66 Electronic Fan Speed Controls. 2. Remove and discard wire 129/BL between the contactor (1) and condenser fan motor #1 capacitor (RC1). Connect wire 701 BLUE to the 1 contactor at terminal and the terminal on the P66 HPC1. 3. Connect wire 700 PURPLE to the condenser fan motor #1 capacitor (RC1) and the 1 terminal on the P66 HPC1. 4. Remove outdoor fan control (PSC) and wiring. Install jumper wire 708 ORANGE from relay terminal #4 to 3 contactor coil in place of the 250/O wire. 5. Connect wire 704 ORANGE to the relay at terminal #4 and the orange wire from the P66 HPC1. 6. Connect wire 705 BROWN to and the brown wire from the P66 HPC1. WIRING HPC2 1. Refer to the wiring diagram in Figure 1 for connection of the Johnson Controls P66 Head Pressure Control. 2. Remove and discard wire 130/Y between contactor (3) and condenser fan motor #2 capacitor (RC2). Connect wire 703 BLUE to the 3 contactor at terminal and the terminal on the P66 HPC1. 2 Johnson Controls Unitary Products

3. Connect wire 702 PURPLE (from the kit) to the condenser fan motor #2 capacitor (RC2) and the 1 terminal on the P66 HPC2. 4. Connect wire 706 ORANGE to the relay at terminal #4 and the orange wire from the P66 HPC1. 5. Connect wire 707 BROWN to and the brown wire from the P66 HPC2. 575 VOLT UNITS WIRING HPC1 & HPC2 1. Refer to the wiring diagram in Figure 2 for connection of the Johnson Controls P66 Electronic Fan Speed Controls. 2. Remove and discard wire 129/BL between contactor (1) and condenser fan motor #1 capacitor (RC1). 3. Connect wire 700 PURPLE to the condenser fan motor #1 capacitor (RC1) and the 1 terminal on the P66 HPC1. 4. Remove and discard wire 130/Y between contactor (3) and condenser fan motor #2 capacitor (RC2). 5. Connect wire 702 PURPLE to the condenser fan motor #2 capacitor (RC2) and the 1 terminal on the P66 HPC2. 6. Use a wire nut to join wires 701 BLUE and 703 BLUE from the terminal on the P66 HPC1 and HPC2 to wire 711 which will connect to the Buck Boost Transformer. 7. Connect wire 709 YELLOW from the 3 contactor terminal to the buck/boost transformer. 8. Connect wire 710 BLACK from the 3 contactor terminal to the buck/boost transformer. 9. Remove and discard outdoor fan control (PSC), wire 251/BK and 250/O. Install jumper wire 708 ORANGE from relay terminal #4 to 3 contactor coil. 10. Connect wire 704 ORANGE to the relay at terminal #4 and the orange wire from the P66 HPC1. 11. Connect wire 705 BROWN to and the brown wire from the P66 HPC1. 12. Connect wire 706 ORANGE to the relay at terminal #4 and the orange wire from the P66 HPC2. 13. Connect wire 707 BROWN to and the brown wire from the P66 HPC2. OPERATION The P66 varies the outdoor fan motor speed to maintain higher head pressure in low ambient temperatures. It has a 170-230 psig operating range. If the head pressure is below the operating range, the motors remain off. As the pressure rises through the operating range, the output voltage to the motors varies from a start voltage of 40% to 90% of line voltage at the top of the range. As the pressure rises above the operating range, the output voltage increases at a lesser rate to a maximum of 97% of line voltage at 260 psig. Johnson Controls Unitary Products 3

1-1 1-2 L2 700/PR RC1 1 F1 L3 1-3 701/BL 1 HPC1 704/O 705/BR 3 F2 3-1 702/PR RC2 2 L2 3-2 703/BL 1 HPC2 706/O 707/BR 3 FIGURE 1-208/230 & 460 VOLT WIRING 4 Johnson Controls Unitary Products

H1 H3 H2 H4 Buck Boost Transformer X4 X2 X3 X1 710/BK 709/Y 711/BL 701/BL 700/PR 1 RC1 1 F1 HPC1 3-1 3 704/O 705/BR 3-2 L2 702/PR RC2 2 F2 703/BL HPC2 1 706/O 707/BR 3 FIGURE 2-575 VOLT WIRING Johnson Controls Unitary Products 5

Subject to change without notice. Printed in U.S.A. Copyright 2009 by Johnson Controls, Inc. All rights reserved. Johnson Controls Unitary Products 5005 York Drive Norman, OK 73069 350160-UAI-B-0709 Supersedes: 350160-UAI-A-1207