Data Sheet High Velocity Water Spray Nozzle. Issue B. Rapidrop Global. Ref: SPTDHV/E TECHNICAL DATA MAINTENANCE DESCRIPTION

Similar documents
Data Sheet 11.2 Issue B

Data Sheet 11.1 Issue A

HIGH VELOCITY WATER SPRAY NOZZLE (BRASS)

MODEL: HV-AS & HV-BS TECHNICAL DATA : MAINTENANCE DESCRIPTION PRESSURE (3/4 NPT OPTIONAL)

Data Sheet Issue E

MEDIUM VELOCITY WATER SPRAY NOZZLE

WATER SPRAY NOZZLE DATA SHEET

MEDIUM VELOCITY WATER SPRAY NOZZLE

TECHNICAL DATA SHEET. Medium Velocity Water Spray Nozzle. Page 1. Description. Technical and Environmental Specification. Installation & Maintenance

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

INLINE FOAM INDUCTOR HD FIRE PROTECT PVT. LTD. TECHNICAL DATA DESCRIPTION SPECIFICATION APPLICATION SYSTEM DESIGN DETAILS

SPRAYTECS Series UP High Velocity Directional Spray Nozzles, Open, Non-Automatic. Suitable for Water Spray fixed systems.

MODELS F822 THRU F834

model E Spray nozzles vk810 - vk817

ROMAN TUB 3 VALVE LONG STEM AND TRIM INSTALLATION INSTRUCTIONS Valve Body No Trim Kit for Model No s: 1047, 1707, 1727

TECHNICAL DATA VK810 (65 ) VK811 (80 ) VK812 (95 ) VK813 (110 )

STYLE 5148 MERCURYMASTER OSCILLATING NOZZLE INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS

Service Guide JATCO Environmental Protection Tank Model J-7000

Grinnell Grooved Fire Protection Products Grooved Fittings

STYLE 5148 MERCURYMASTER OSCILLATING NOZZLE INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS

HR-20P Pneumatically Controlled Pressure Regulator

Instructions and Parts List 3M-Matic P/N Infeed/Exit Conveyor Attachment, 1.2 Meter

SOLID CONE SPRAY NOZZLES TECHNICAL DATA

GM Specification Annual Test Data

GW THERMOCOOL NOZZLE STRUCTURAL STEEL PROTECTION

Directional Spray Nozzles, Open, with Strainers High Velocity General Description

WEB CONTROL PRODUCTS

STYLE 624, 638 QUICK-ATTACK FOAM TUBE INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS

GM Specification Annual Test Data

007 Tank Monitor. WARNING Never use with gasoline or highly flammable liquids.

INSTALLATION AND OPERATING MANUAL

AVK SERIES 41 SWING CHECK VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR SWING CHECK VALVES 3" - 12"

INSTALLATION & MAINTENANCE GUIDE

4077 AIRPARK DRIVE STANDISH, MICHIGAN PHONE FAX

Model CP420/CP425. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO

BATHROOM ACCESSORIES

AVK SERIES 41 SWING CHECK VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR SWING CHECK VALVES 3" - 12"

Intended Use: Explanation of Signal Word Consequences

DAP-625S and DAP-875S

AMERICAN AVK COMPANY TABLE OF CONTENTS

Series Description. 2 Specifications. Traffic Safety and Security Division. Product Bulletin Series 4000ESV 06/2017

1000-LB. MOTORCYCLE LIFT TABLE OWNER S MANUAL

TBM Series 3-Way Ball Valve

18660, 18661, & Stealth Fuel Cell INSTALLATION INSTRUCTIONS

Installation Instructions / Warranty

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

Telescoping Pressure Washer Wand 18'

1000-LB. ENGINE STAND

Models P420A-3100 & P420A-5100

Transmission Guardian

Penguin Gentoo 600B Cordless Sprayer User s Manual

Straight-Bore Clutch LSCC-32, 44, 54

Single Post Caliper Brake VC500

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09

MODEL 900 IMPELLER-TYPE FLOW METER

Injection/Sample Quills

Operating Instructions & Parts Manual. Oil Control Gun. Models 48UJ82, 48UJ83, 48UJ84, 48UJ85 and 48UJ86

INSTALLATION AND OPERATING MANUAL

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Installation Instructions / Warranty. Citterio 39115XX1

2000-LB. ENGINE STAND

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-122 REV A 12/09

Installation Instructions / Warranty. Raindance Allrounder 28110XX1 Wall Outlet Adapter with Hose Connection 28108XX1

GETZ EQUIPMENT INNOVATORS PART NO.: 3G59419 MODEL: BV 101 P PNEUMATIC BELT VISE WITH EXTENDED BELT & ROLLER

Reference Manual FM-200 Series

DELUGE VALVE DATA SHEET

Model GP Triplex Ceramic Plunger Pump Operating Instructions/ Manual

INTRODUCTION INSTALLATION

TECHNICAL DATA OBSOLETE

Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.

AEROMOTIVE Part # A3000 Regulator Assembly INSTALLATION INSTRUCTIONS

Type D3S PROTECTOSPRAY Directional Spray Nozzles, Open, Medium Velocity General Description. Technical Data. Page 1 of 6 AUGUST 2018 TFP804

RipTide. Brewing Pump. Assembly, Operation, & Maintenance

Watts Series CSM-61. Flow Measurement/Balancing Valves Sizes: 1 1 4", 1 1 2", 2", 2 1 2", and 3" (32, 40, 50, 65 and 80mm) Installation Instructions

Crescent Flush Manifold FOR LIQUID LAUNDRY SUPPLY SYSTEMS

Installation Instructions / Warranty. Axor Citterio M 34315XX1

11202 INSTALLATION INSTRUCTIONS

Operators Manual. Model 3370 Air Cooled Recirculator rev.8/98

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

Single-Position Detent Clutch DC Series. (i) MTY (81) MEX (55) QRO (442)

18318 INSTALLATION INSTRUCTIONS CHEVROLET IMPALA

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser

13101 / / and Installation Instructions

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

Manual Transfer Switch

PT-516 Pumping Trap Installation and Maintenance

Web Volume Control Model WV220

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

P SERIES PUMPS. 18mm Versions Nickle-Aluminum Bronze Models: P , P , P , P , P , P , P

Series CP200. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual. For Models: CP218 CP219 CP220 CP230

BMK-30. Heavy-Duty By-Pass Filtration System Installation and Servicing Instructions

Installation Instructions / Warranty

J 6 Se r i e s. Pressure and Vacuum switches. features

SAFETY INFORMATION & INSTRUCTION MANUAL

Elgin Hydraulic Clutch-Brake ECB-240, Product Number FORM NO. L F FORM NO. L F-0704

OPERATOR S MANUAL HD 2.3/24 P CD HD 2.3/23 P CD

DIRECT-DRIVE PRESSURE WASHERS

Transcription:

Ref: SPTDHV/E Jan, 2011 Technical Data TECHNICAL DATA MODEL MAXIMUM WORKING PRESSURE EFFECTIVE WORKING PRESSURE END CONNECTION DESCRIPTION HV-AS with strainer 12 Bar (175 PSI) 3.5 Bar to 10.5 Bar (50-150 PSI) ¾" BSPT (¾" NPT OPTIONAL) MATERIAL Housing & Scroll - Brass IS : 291 (EQUIVALENT TO ASTM- B21) Strainer - Copper INCLUDED WATER SPRAY K-FACTOR SPRAY ANGLE AND ANGLE METRIC (US) K-FACTOR 75-22 (1.54) 80-18 (1.26) 90-32 (2.24) 100-26 (1.82) 115-42 (2.94) 120-23 (1.61) WEIGHT (Approx) FINISH APPROVALS ORDERING INFORMATION 0.200 Kg Brass Finish Nickel Chrome Plated (optional) UL Listed Specify Model, K-Factor, Spray angle and Finish any affecting the spray pattern of the nozzle must be considered. The nozzle may be oriented in any position as deemed necessary to cover the hazard. 3.5 bar to 7 bar pressure at Nozzle is recommended for effective application requiring High Velocity Water delivery for rapid extinguishment of all fires by emulsification. The Nozzles are having inbuilt Strainer, but still main pipeline strainer is required in the system. The Blow-off cap can be used to prevent the depositing of foreign material in the water way of the nozzle.use of Blow-off cap is optional and not UL listed. MAINTENANCE s are internal swirl plate type open nozzles designed for use in fixed water spray or deluge system for the fire protection application. These nozzles produce solid uniform and dense core of high velocity water spray to effect fire control. Nozzles are normally used to cool the surface as well as for extinguishment. Nozzles are typically used for Deluge protection of special hazards such as oil filled transformers, switch-gear, chemical process equipments, conveyor system and flammable liquid storage areas. The minimum desirable pressure to achieve a reasonable spray pattern is (50 psi). The water distribution pattern is as shown in the graph in following pages giving maximum effective axial distance from the nozzle. The spray pattern shown is with indoor application. The system designer must consider wind velocity while designing the system for outdoor application. Field obstruction if The spray nozzle must be handled with due care. For best results, the storage as well as any further shipment be made in original packing only. Nozzle which is visibly damaged should not be installed. Use Teflon tape or soft thread sealant on the male thread of the nozzle. It is recommended that the water spray system be inspected by an authorised technical personnel. The nozzle must be checked for corrosion, external and internal obstruction, blockage if any. The nozzle should be cleaned or replaced if required. The system must be operated with optimum water flow at least three times in a year or as per the provision of NFPA/TAC or local authority having jurisdiction. The owner is solely responsible for maintaining the water spray system and components therein, so that it performs properly when required. Page 1 of 5

HV-AS Jan, 2011 Ref: SPTDHV/E Technical Data C B A DIMENSION In millimeters ( Approximate ) NOZZLE FACTOR A B & SPRAY ANGLE C A/F K 22 x 75 49 21 30 K 18 x 80 44 21 30 K 32 x 90 49 21 30 K 26 x 100 55 21 30 K 23 x 120 49 21 30 K 42 x 115 49 21 30 DISCHARGE CHARACTERISTICS 30 PRESSURE IN PSI 60 90 120 150 175 140 120 K42 30 L P M = FL OW IN Q 100 80 60 K32 K26 K23 K22 K18 20 G P M FLOW IN 40 10 20 0 2 4 6 8 10 12 P - PRESSURE IN Kg./Sq.Cm. Q =K P where P is supply pressure in Kg/sq.cm., K= nozzle constant (K-factor) in metric US K factor = Metric K factor 14.2745 Page 2 of 5

SPRAY PATTERN K22 X 75 K18 X 80 K32 X 90 Data Sheet 11.2 3.5 4 5 7 4 5 7 3.5 K g./sq.cm. 4 K g./sq.cm. 5 K g./sq.cm. 7 K g./sq.cm. 3. 3. 3. Page 3 of 5

SPRAY PATTERN K42 X 115 K23 X 120 3.5K g./sq.cm. 4K g./sq.cm. 5K g./sq.cm. 7K g./sq.cm. 3.5K g./sq.cm. 4K g./sq.cm. 5K g./sq.cm. 7K g./sq.cm. 4 3. 3. 3. 3. 3. 3. 3. 3. Page 4 of 5

SPRAY PATTERN K26 X 100 Data Sheet 11.2 3.5 4 5 7 3. 7 5 4 4 5 7 LIMITED WARRANTY Products supplied by Rapidrop (RD) are warranted against defects in material and workmanship for a period of Two (2) years from the date of shipment. RD s obligation under this warranty is limited to replace or repair the products or its parts, which are shown to RD s examination to be in a defective condition attributable to RD. No warranty is given for products or components which have been subject, to misuse, improper installation, corrosion, wear and tear replacement, then RD may elect to refund the purchase price of the equipment in complete discharge of its obligation under this Limited Warranty. IN NO EVENT SHALL RAPIDROP. BE LIABLE IN CONTRACT, STRICT LIABILITY OR ANY OTHER LEGAL THEORY, FOR INCIDENTAL, IN-DIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING DAMAGES. FOR INJURY TO PERSON OR DEATH OR DAMAGE TO PROPERTY AND OR PENALTIES RESULTING FROM ANY PRODUCTS OR COMPONENT MANUFACTURED OR ASSEMBLED BY RD. THIS IS LIMITED WARRANTY ONLY. RD DISCLAIMS WITH RESPECT TO THE PRODUCTS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND ALL IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE. THERE IS NO WARRANTY OF ANY NATURE MADE BY RD BEYOND AS STATED ABOVE. NOTICE : The equipment presented in this bulletin is to be installed in accordance with the latest publication standards of NFPA or other similar organisations and also with the provision of government codes or ordinances wherever applicable. The information provided by us are to the best of our knowledge and belief, and are general guidelines only. Site handling and installation control is beyond our reach. Hence we give no guarantee for result and take no liability for damages, loss or penalties whatsoever, resulting from our suggestion, information, recommendation or damages due to our product. Product development is a continuous programme of RAPIDROP company. Page 5 of 5