DeZURIK AFR3 Filter Regulator Used on Pneumatic Cylinder Actuators

Similar documents
DeZURIK KUL KNIFE GATE VALVES

DeZURIK 2-24 (50-600mm) KGN-RSB BI-DIRECTIONAL CAST STAINLESS STEEL KNIFE GATE VALVES

DeZURIK 2 20" BOS BUTTERFLY VALVES

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

DeZURIK 2-24 (50-600mm) KGC ES or HD KNIFE GATE VALVES

APCO CSV-1600 SURGE CHECK VALVE

DeZURIK KGC-MD KNIFE GATE VALVES

Nor East. Instructions. Safety Messages. Inspection. Parts Nor East Controls. Service. Type 05 Air-O-Motor Actuator Used With Globe Valves

Nor East. Instructions Safety Messages. Inspection. Parts. DeZURIK Service. Type 05 Pneumatic Actuator Used With Globe Valves

DeZURIK 24 and Larger BHP High Performance Butterfly Valves WITH (FB) FYRE-BLOCK SEAT

APCO CVS-6000 CONVERTIBLE SWING CHECK VALVES

Recommended spare parts are listed on the assembly drawing. These parts should be stocked to minimize downtime.

DeZURIK KSV CL150 & CL300 BONNETLESS KNIFE GATE VALVES

DeZURIK PEC ECCENTRIC VALVES

DeZURIK 24" THRU 36" RESILIENT BUTTERFLY VALVES

DeZURIK 2-16" PTW & PFW TAPERED PLUG VALVES

APCO SRG-6500 SURGE RELIEF GLOBE VALVES

DeZURIK VPB V-PORT BALL VALVES

APCO ACS-1200/1700 COMBINATION SLOW CLOSING AIR/VACUUM VALVE

APCO CVS-250/250A SWING CHECK VALVES

DeZURIK " PEC ECCENTRIC VALVES

CSA products for waste water. Combination air valve. Mod. SCF 2

CSA products for treated water. Water Combination air valve. Mod. FOX 3F RFP and Lynx 3F RFP

CSA products for waste water. Anti water hammer combination air valve. Mod. SCF-RFP

Nor East /9500 Series Double Seated Cage Valves. Instructions. Safety Messages. Inspection. Parts. Nor East Controls Service

DeZURIK BHP HIGH PERFORMANCE BUTTERFLY VALVE

DeZURIK TEN-POSITION LEVER MANUAL ACTUATOR

DeZURIK PNEUMATIC CYLINDER OPERATOR FOR G-SERIES ACTUATORS

DeZURIK CYLINDER OPERATED T-SERIES ACTUATOR

APCO CVS-6000 SWING CHECK VALVES

MANUAL ACTUATOR FOR KNIFE GATE VALVES

DeZURIK SPRING RETURN CYLINDER OPERATOR FOR G-SERIES ACTUATORS USED ON PEF 100% PORT ECCENTRIC VALVES

DeZURIK DR 125 ROTARY DIAPHRAGM ACTUATOR

DeZURIK MANUAL G-SERIES ACTUATORS USED ON PEC ECCENTRIC VALVES

CSA products for treated water. Equilibrium float valve. Mod. Athena

DeZURIK DR 40B ROTARY DIAPHRAGM ACTUATOR

HR-20P Pneumatically Controlled Pressure Regulator

DeZURIK LA-SERIES MANUAL & ELECTRIC ACTUATORS

DeZURIK MODELS P41, P41D AND P42 PMV POSITIONERS

APCO SRA-3000A SURGE RELIEF ANGLE VALVES

DeZURIK M-SERIES MANUAL ACTUATOR

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

MetroPrime 22MPC Self-Priming Centrifugal Pump

PMV P36C AND P41C POSITIONERS ACTUATORS

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

DeZURIK MANUAL G-SERIES ACTUATOR USED ON PEF 100% PORT PLUG VALVES

DAP-625S and DAP-875S

StormPro BA Series Sump Pump

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO

Single-Position Detent Clutch DC Series. (i) MTY (81) MEX (55) QRO (442)

Elgin Hydraulic Clutch-Brake ECB-240, Product Number FORM NO. L F FORM NO. L F-0704

4-Ton Electric Log Splitter

CRD600 Automatic Fitting Inserter

Tissue Master. User Manual

CRD610 Automatic Fitting Inserter

Air Control Kit INSTRUCTIONS-PARTS LIST. Table of Contents HIGH VOLUME. 250 psi (1.7 MPa, 17.2 bar) Maximum Air Inlet Pressure

FCB-450, LCB-600, MCB-800

SERIES RSR PRESSURE RELIEF VALVE

DeZURIK G-SERIES MANUAL ACTUATOR USED ON BOS BUTTERFLY VALVES

Straight-Bore Clutch LSCC-32, 44, 54

MEX (55) QRO (442) Web Controls

DeZURIK R1 POWERRAC ACTUATOR ON 1/2-3" PEC ECCENTRIC VALVES

Installation Power Management Unit Battery Cables and Battery Harness

TBM Series 3-Way Ball Valve

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases

Open Display Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

StormPro BCV400 Sewage Ejector Pump

A48 / A48B (base plate) BATTERY CHARGER

Installation / Operation Instructions Sunnex ORION Series Exam Lights

Parts Manual Vermeer/ McLaughlin Mud System 230P

Instruction Manual. Fudge Puppy Display Case

92831 TEL: (714) FAX:

Ion Technologies WC33 Submersible Sump Pump

JET METER INSTRUCTIONS

!"" #$% "!&' ( ( ) *

Single Post Caliper Brake VC500

Dual/Triple Manifold Water Filtration Systems Instruction Manual

Presoak & Tire/Engine Cleaner Systems (Air Pump) DU TC_A & DU PS_A

Customer Support

Pressure Roller with 24-inch Fixed Extension - For application of architectural paints and coatings -

Installation and Maintenance Manual

Parts Manual Vermeer/ McLaughlin Mud System 230P

Cardinal DETECTO. PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual

Switch-Tek Horizontal and Vertical And Float-Point Float Switches LV20, LV21, LV35, LV36, LH25, LH29, LH35, AV_6 Series 22AUG 08 Rev A

PCC O P E R A T I O N S. Pump Cycle Counter M A N U A L. Environmental Systems

Ion Technologies SHR-HR Submersible Sewage Pump Single Seal, Single Phase, & Three Phase Power

TONS. Before each shift: Before operating: Before initial operation of hoist:

Level Alert Model Multi-Switch Liquid Level Sensor. Assembly and Installation Instructions

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

Model AS-RC3260 TV Cart. Rolling Cart for Audio Mount System & Flat Panel TVs

Inline & 90 Live Swivels Fax:

A Member of the. Integrated Metering Technologies

"WHERE TUBING AND FITTINGS COME TOGETHER"

Installation Guide Document N Cleanroom Mirrors Copyright 2016 Terra Universal Inc. All rights reserved. Revised November 2016

HQZ & RBM MODEL LIFT & TRANSFERS

Cincinnati, OH USA

Through-Shaft Clutch-Brake LSCB-32HT, LSCB-32HT, LSCB-44, LSCB-44HT, LSCB-54HT FORM NO. L D-0606 MEX (55) QRO (442)

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

Installation & Operation Manual Chef Base

Transcription:

AFR3 Filter Regulator Used on Pneumatic Cylinder Actuators Instructions D11033 August 2013

Instructions These instructions provide information about AFR3 Filter Regulators. They are for use by personnel who are responsible for installation, operation and maintenance of AFR3 Filter Regulators. Safety Messages All safety messages in the instructions are flagged with the word Caution, Warning or Danger. These messages must be followed exactly to avoid equipment damage, personal injury or death. Safety label(s) on the product indicate hazards that can cause equipment damage, personal injury or death. If a safety label becomes difficult to see, or if a label has been removed, please contact DeZURIK for replacement. WARNING! Personnel involved in the installation or maintenance of valves should be constantly alert to potential emission of process material and take appropriate safety precautions. Always wear suitable protection when dealing with hazardous process materials. Handle valves which have been removed from service with the assumption of process material within the valve. Inspection Your AFR3 has been packaged to provide protection during shipment. Carefully inspect the unit for damage upon arrival and file a claim with the carrier if damage is apparent. Parts Recommended spare parts are listed on the assembly drawing. These parts should be stocked to minimize downtime. Order parts from your DeZURIK sales representative, or directly from DeZURIK. When ordering parts, please include the 7-digit part number and 4-digit revision number (example: 9999999R000) located on the data plate attached to the valve assembly. Also include the part name, the assembly drawing number, the balloon number and the quantity stated on the assembly drawing. DeZURIK Service DeZURIK service personnel are available to install, maintain and repair all DeZURIK products. DeZURIK also offers customized training programs and consultation services. For more information, contact your local DeZURIK sales representative or visit our website at www.dezurik.com. D11033 2013 DeZURIK

Description The AFR3 Filter Regulator allows air pressure to be adjusted to match the requirements of the actuator (see the documentation envelope or IOM package supplied with your hardware for proper pressure settings). An internal filter traps water and other contaminants before they can cause excessive wear or damage to actuator components. Installation Blow out the air supply pipe to remove scale or other contaminants prior to installation. Install the regulator as close as possible to the instrument being supplied. For best filter drainage, position the unit so that the drain valve is at the lowest point on the dripwell housing. The unit must be installed with the flow in the direction of the flow arrow on the body cover and the bowl down. WARNING! The AFR3 is designed for air service only. Maximum allowable inlet pressure is 250 psi (1725 kpa). Operating temperatures are 32 to 150 ºF (-0 to 65 ºC). To avoid exceeding outlet pressure limits while in service, a pressure relieving or pressure limiting device should be provided. Operation To increase regulated pressure, pull adjusting knob up and turn clockwise. To reduce pressure, turn knob counterclockwise. To lock knob, push down. August 2013 Page 3 D11033

Maintenance WARNING! Failure or improper selection or improper use of the products and/or systems described herein or related items can cause death, personal injury and property damage. Depressurize both upstream and downstream pressure. 1. Filter element replacement: a. Depressurize both upstream and downstream pressure. b. Remove bowl / bowl guard assembly by pushing up on bowl assembly and turning counterclockwise (viewed from below). Clean inside of bowl using a clean, dry cloth. Inspect plastic bowl for damage and replace if necessary. c. Remove filter element by turning retainer counterclockwise. d. Remove old element and discard. Care must be taken at this step not to lose or misplace the valve spring and valve assembly, as these components may be removed during this procedure. e. Install a new filter element and reassemble in reverse order. See table side for torque values. 2. Valve assembly: a. Depressurize both upstream and downstream pressure. b. Remove bowl / bowl guard assembly and element retainer assembly as outlined in maintenance Step #1. Care must be taken at this step not to lose or misplace the valve spring and valve assembly, as these components may be removed during this procedure. c. Remove the valve spring and valve assembly, if not already done. d. Inspect all seals and components for damage and replace as required. Clean seals and components with mild detergent and water (No Solvents!). Use a clean, dry cloth to wipe any contamination from the valve seat inside the body. e. Lubricate valve stem and lower valve O-ring seal with a light coat of lubricant. f. Reassemble in reverse order. See table on reverse side for torque values. 3. Main Spring and Diaphragm: a. Depressurize unit, both upstream and downstream. b. Turn adjusting knob counterclockwise to remove all spring force, then remove bonnet by turning counterclockwise. c. Remove adjusting screw assembly, main spring, slip ring and diaphragm assembly. d. Inspect diaphragm and the relief seat, on relieving models, for damage or contamination. Replace diaphragm assembly if necessary. Clean relief seat with a soft, dry cloth. Reassemble in the reverse order making sure slip ring is properly positioned on top of the diaphragm. Bonnet torque values are shown in the table below. August 2013 Page 4 D11033

Maintenance continued 4. Liquid level in the bowl must be kept below the level indicator line as marked. It is recommended practice to drain a unit equipped with the manual drain at least once during an eight (8) hour period. To do so, rotate the drain knob to the left one or two turns.* 5. Before returning unit to service, insure that all seals have been properly reinstalled or replaced and components requiring torque have been properly tightened. Also, insure that bowl seal O-ring and bowl have been installed properly and that the bowl is in the locked position and the drain is properly secured. Note: In the event the drain knob is over-rotated, it may become disengaged from the drain stem. In such a case, pull down on both the knob and the stem while rotating clockwise to re-engage. (view from below) 1 2 3 4 5 6 7 8 9 10 13 14 15 16 17 23 18 24 25 19 26 27 28 1. KNOB 2. PANEL NUT 3. BONNET 4. BODY COVER 5. THRUST WASHER 6. ADJUSTING SCREW ASSEMBLY 7. MAIN SPRING 8. SLIP RING 9. DIAPHRAGM ASSEMBLY 10. BODY ASSEMBLY 11. VALVE ASSEMBLY 12. VALVE SPRING 13. OLD DESIGN 14. NEW DESIGN 15. DEFLECTOR 16. 5 MICRON ELEMENT 17. RETAINER 18. AUTOMATIC FLOAT DRAIN 19. AUTO DRAIN O-RING 20. BOWL O-RING 21. NETAL BOWL W/SIGHT GAUGE 22. AUTOMATIC DRAIN NUT 23. DRAIN STEM 24. DRAIN STEM O-RING 25. DRAIN SEAT 26. DRAIN SEAT O-RING 27. PLASTIC BOWL/BOWL GUARD ASSEMBLY 28. DRAIN KNOB 21 11 12 22 28 August 2013 Page 5 D11033

Guarantee Products, auxiliaries and parts thereof of DeZURIK, Inc. manufacture are warranted to the original purchaser for a period of twenty-four (24) months from date of shipment from factory, against defective workmanship and material, but only if properly installed, operated and serviced in accordance with DeZURIK, Inc. recommendations. Repair or replacement, at our option, for items of DeZURIK, Inc. manufacture will be made free of charge, (FOB) our facility with removal, transportation and installation at your cost, if proved to be defective within such time, and this is your sole remedy with respect to such products. Equipment or parts manufactured by others but furnished by DeZURIK, Inc. will be repaired or replaced, but only to the extent provided in and honored by the original manufacturers warranty to DeZURIK, Inc., in each case subject to the limitations contained therein. No claim for transportation, labor or special or consequential damages or any other loss, cost or damage shall be allowed. You shall be solely responsible for determining suitability for use and in no event shall DeZURIK, Inc. be liable in this respect. DeZURIK, Inc. does not guarantee resistance to corrosion, erosion, abrasion or other sources of failure, nor does DeZURIK, Inc. guarantee a minimum length of service. Your failure to give written notice to us of any alleged defect under this warranty within twenty (20) days of its discovery, or attempts by someone other than DeZURIK, Inc. or its authorized representatives to remedy the alleged defects therein, or failure to return product or parts for repair or replacement as herein provided, or failure to install and operate said products and parts according to instructions furnished by DeZURIK, Inc., or misuse, modification, abuse or alteration of such product, accident, fire, flood or other Act of God, or failure to pay entire contract price when due shall be a waiver by you of all rights under this warranty. The foregoing guarantee shall be null and void if, after shipment from our factory, the item is modified in any way or a component of another manufacturer, such as but not limited to, an actuator is attached to the item by anyone other than DeZURIK, Inc. Factory Service personnel. All orders accepted shall be deemed accepted subject to this limited warranty, which shall be exclusive of any other or previous Warranty, and this shall be the only effective guarantee or warranty binding on DeZURIK, Inc., despite anything to the contrary contained in the purchase order or represented by any agent or employee of DeZURIK, Inc., in writing or otherwise, notwithstanding, including but not limited to implied warranties. THE FOREGOING REPAIR AND REPLACEMENT OBLIGATIONS ARE IN LIEU OF ALL OTHER WARRANTIES, OBLIGATIONS AND LIABILITIES, INCLUDING ALL WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR OF MERCHANTABILITY OR OTHER- WISE, EXPRESSED OR IMPLIED IN FACT OR BY LAW, AND STATE DEZURIK, INC. S ENTIRE AND EXCLUSIVE LIABILITY AND YOUR EXCLUSIVE REMEDY FOR ANY CLAIM IN CONNECTION WITH THE SALE AND FURNISHING OF SERVICES, GOODS OR PARTS, THEIR DESIGN, SUITABILITY FOR USE, INSTALLATION OR OPERATIONS. Limitation of liability LIMITATION OF LIABILITY: IN NO EVENT SHALL DEZURIK, INC. BE LIABLE FOR ANY DIRECT, INDIRECT, SPECIAL OR CONSE- QUENTIAL DAMAGES WHATSOEVER, AND DEZURIK, INC. S LIABILITY, UNDER NO CIRCUMSTANCES, WILL EXCEED THE CON- TRACT PRICE FOR THE GOODS AND/OR SERVICES FOR WHICH LIABILITY IS CLAIMED. ANY ACTION BY YOU FOR BREACH OF CONTRACT MUST BE COMMENCED WITHIN 12 MONTHS AFTER THE DATE OF SALE. Sales and Service For information about our worldwide locations, approvals, certifications and local representative: Web site: www.dezurik.com E-Mail: info@dezurik.com 250 Riverside Ave. N. Sartell, Minnesota 56377 Phone: 320-259-2000 Fax: 320-259-2227 DeZURIK, Inc. reserves the right to incorporate our latest design and material changes without notice or obligation. Design features, materials of construction and dimensional data, as described in this manual, are provided for your information only and should not be relied upon unless confirmed in writing by DeZURIK, Inc. Certified drawings are available upon request.